tri chlorine generator instruction manual and … · 1 welcome to zodiac congratulations on your...

Post on 16-Apr-2018

219 Views

Category:

Documents

1 Downloads

Preview:

Click to see full reader

TRANSCRIPT

TRi ChloRine GeneRaToR

insTRuCTion Manual and WaRRanTy CaRd

1

Part: Qty: description:

a. 1 TRiPowerpack

b. 1 Chlorinegeneratingcell

c. 1 Powerpackbracket

d. 2 Reducingbushes

This KiT ConTains:

1

WelCoMe To ZodiaC

CongratulationsonyourpurchaseofaproductfromtheZodiacrangeofpoolcareproducts.Zodiacproductsaredesignedtoletyouspendmoretimeenjoyingyourpoolandlessonmaintenance.

iMPoRTanT infoRMaTion

YOUMUSTREADTHISINFORMATIONBEFOREINSTALLATION.ALWAYSREADTHELABELANDOPERATIONMANUALBEFOREUSING.PLEASEKEEPYOURMANUALASITCONTAINSYOURWARRANTY.

2 3

ZodiaC Believes in safeTy fiRsT

AtZodiac,wetakesafetyseriously.Alwaysexercisecautionwhenusingelectricalappliancesandfollowtheinstructions.Failuretodosocouldresultinpermanentinjury,electrocutionordrowning.

GeneRal WaRninGs

Zodiacsaltwaterchlorinegeneratorsaredesignedfordomesticswimmingpooluseonly.Contraryusecouldaffectperformanceandvoidwarranty.

Operatingachlorinegeneratorwithoutwaterflowingthroughthecellmaycauseabuildupofflammablegases,resultinginfireorexplosion.

Keepequipmentoutofreachofchildren.

Adamagedsupplycordshouldonlybereplacedbythemanufacturer,authorizedserviceagentorelectrician.

Wheninstallingandusingthiselectricalequipment,alwaysfollowbasicsafetyprecautions.

Beforeperforminginstallation,disconnectallpower.

Forswimmingpools,Australianstandardsrecommendaminimumof1PartPerMillion(ppm)offreeavailablechlorinemustbemaintainedatalltimes.

ServicetoZodiacequipmentshouldonlybecarriedoutbyqualifiedandauthorizedpoolprofessionals.

2 3

ZodiaC Believes in safeTy fiRsT

Child safeTy

Childrenshouldnotbeallowedtooperateorperformmaintenanceonthisproduct.

Noone,particularlychildren,shouldsit,step,lean,orclimbonanyofyourpool’soperationalsystem.

Intheinterestsofchildsafety,allcomponentsofapool’soperationalsystemshouldbelocatedatleast3.5metresawayfromthepool.

eleCTRiCal haZaRd

Toavoidaccidentalcontactwithlawnmowersandhedgetrimmers,powercordsshouldremainwithinsightandabovegroundatalltimes.

TheZodiacTRIPowerpackmustnotcomeintocontactwithwaterandmustbeinstalledatleast3.5metresfromtheinsidewallofyourswimmingpool.

Shouldalackofwaterbedetected,theunit’selectronicflowswitchisdesignedtoturnoffthesystem.Interferingwiththeelectronicflowswitchcouldresultinpersonalinjuryand/ordamagetothecell.

Onepumpperelectricalsocketonly(noancillaryequipmentshouldbeconnectedtothesameoutlet).

Thisapplianceisnotintendedforusebypersons(includingchildren)withreducedphysical,sensoryormentalcapabilities,orlackofexperienceandknowledge,unlesstheyhavebeengivensupervisionorinstructionconcerninguseoftheappliancebyapersonresponsiblefortheirsafety.

Childrenshouldbesupervisedtoensurethattheydonotplaywiththeappliance.

TheinstallationofthechlorinatorshouldbecarriedoutbyaqualifiedpersoninaccordancewiththeAustralianwiringrulesAS/NZS3000.

Thechlorinatorpowerpackshouldbelocatedinthecorrectpoolzoneandconnectedtosupplyviaapoweroutletthatisprotectedbyaresidualcurrentdevice(RCD)havingaratedresidualoperatingcurrentnotexceeding30mA.ThepoweroutletshouldhaveadegreeofprotectionsuitableforthepoolzoneEnsurethatequipotentialbondingofallpartsofthepoolinstallationiscarriedout.

4 5

insTallaTion Guide

ThefollowingstepswillhelpyougetupandrunningwithyournewZodiacTRiChlorinegenerator.

PosiTioninG The PoWeR PaCK

1. Locateasuitablespaceforthepowerpackbracket.Itshouldbeinstallednofurtherthan1.8metresawayfromthecell-ideallyinafiltrationshedorclosetothefiltrationequipment.

PLEASENOTE:iffixingtoapostitmusthaveawaterproofpanelfitted(behindtheunit),atleast450mmwideand470mmhigh.

2. Usingscrewsprovided,fastenthebracketsecurelytothewallandpositionthepowerpackonthebracket.Plugintopowerpoint,butdon’tturnonthepower.

PosiTioninG The ChloRine GeneRaTinG Cell

PLEASENOTE:Thecellshouldalwaysbethelastdeviceplacedonthewaterpipe(Inthereturnlinetothepool).

3. Ensurethecellisplacedhorizontally,withtheInletpipeconnectingtothefittingclosesttothecelllead.

4. Usingscrewbarrelfittings(supplied),attachthecelltothepipe.Ifusing40mmpipe,youwillneedtofitthecellusingthereducingbushes(alsosupplied).

5. Whenconnectingtheleadfromthepowerpacktothecellmatchupthecorrespondingcoloursandpins,thenfittheendcap.

(Note:EitherREDwirecanbeconnectedtoeitherREDpinontheelectrode.)

6. PlugyourpoolpumpintotheoutletsocketinthebottomoftheTRi(thiswillallowtheTRitimertocontrolthefiltrationtimes)

7. OnceallconnectionsaretogetherpressthemainspowerswitchtoON.

4 5

naviGaTion BuTTons

UsethefollowingUIbuttonstoaccessandselectallmenusandcommands:

on/off

TurnUIpoweron/off.

uP/doWn

Scrollup/downwithincurrentmenutohighlightaspecificmenucommand.

Menu/BaCK

Entersintothemainmenu,andusedtogobacktopreviousmenu.

seleCT/enTeR

Select/enterscurrenthighlightedmenucommand.Displaythenextrelatedcommandoractivatetheselectedfunction

6 7

usinG inBuilT CloCK and TiMeRs

Whenitcomestochlorination,everypoolisdifferent.Togetwhat’srightforyou,youwillneedtosettheunit’sclockandtimers.

seTTinG The CloCK

1. Switchpoweron.

2. Waitforthestart-upsequencetocomplete.

3. Pressthe buttontoentertheMAINMENU.

4. Use / buttonsandscrolltoSETCLOCK.

5. Press .

6. Use / buttonstosetthehours.

7. Press tosavethehours.

8. Usethe / buttonstosettheminutes.

9. Press tosavetheminutes.

TRiwillthenreturntotheMAINMENU.

10.Press toreturntotheoperatingscreen.

NOTE:Thetimeisdisplayedin24Hourformat

6 7

TuRninG ChloRine GeneRaTion on

ThechlorinegenerationoftheTRicanbecontrolledinanumberofways:

1. Manuallysettoanoutputlevel,withtheoperatingtimesdeterminedbyanexternaltimer.

2. Usingthein-builttimersontheTRiunit(referto‘TheTimers’)

3. Usingaconnectiontoanexternalcontroller(referto‘Connectingtoacontroller’).

Toturnthechlorinegenerationonmanually,presstheON/OFFbutton.Theoutputlevelcanbesetasdescribedin‘SettingtheChlorineOutput.’NOTE:Forsafetyreasons,theTRichlorinegeneratorwillcontinuallydosechlorineforamaximumof30hoursifleftrunningwithno‘OFF’time–unlessconnectedtoenexternalcontroller.Afterthistime

theTRiwillswitchto‘OFF’.

The TiMeRs

TheZodiacTRichlorinegeneratorcomeswithtwoinbuilttimersthatswitchthefiltrationandchlorinationsystemonandoffasrequired.

Duringswimmingseason,considerrunningthesystemforaround8hoursaday.Thiscanbeincreasedto10hoursduringperiodsofveryhotweather.

Inwinter,itmayonlybenecessarytorunyourpool’sfiltrationsystemfor4hoursaday.Theseshorterperiodsofactivitywilllengthenthelifeoftheunit’selectrode.

Forbestyearroundresults,settheunittooperateduringthecoolerhoursoftheearlymorning,eveningorwhenswimmersareusingthepool.

PRoGRaMMinG The TiMeRs

Toactivatethetimer,youwillneedtoenterbothanONandOFFtime.IfnoOFFtimeisentered,thechlorinegeneratorwillswitchoffatthedefaulttimeof12:00am(0:00).

Youwillknowthatavalidtimehasbeenenteredwhena“T”SymbolisdisplayedinthetoprighthandcorneroftheLCDdisplaywhentheunitisdisplayingthe‘operatingscreen’.

usinG inBuilT CloCK and TiMeRs

8 9

usinG inBuilT CloCK and TiMeRs

Toprogramthetimer:

1. Pressthe button.

2. Press buttontomovearrowto‘SETTIMERS’.

3. Press toenterthe‘SETTIMERS’menu.

4. Press / toselectthetimeryouwishtoset.(Timer1orTimer2)

5. Press .

6. Press / tosetthehours(ontime).

7. Press tosavethehours.

8. Press / tosettheminutes(ontime).

9. Press tosavetheminutes.

10.Press / tosetthehours(offtime).

11.Press tosavethehours.

12.Press / tosettheminutes(offtime).

13.Press tosavetheminutes.

TRiwillreturntothe‘SETTIMERS’menu.

8 9

CleaRinG The TiMeRs

Toclearthetimer:

1. Pressthe button.

2. Press / buttontoscrollto‘SETTIMERS’.

3. Press toenterthe‘SETTIMERS’menu.

4. Press / toscrollto‘CLEARTIMERS’.

5. Press .

Aconfirmationmessagewillappearonthescreen.

exTeRnal TiMe CloCK

Attimes,itmaybedesirabletocontrolchlorinegenerationusinganexternaltimeswitch.IfthechlorinegeneratoristurnedON,andtheexternaltimerfailstoswitchthemainspoweroffwithin30hours,theZodiacTRiwillautomaticallystopchlorinatinginordertopreventoverchlorination.

Tosetthechlorinegeneratortorunfromanexternalclock:

1. CleartheTimerbyfollowingtheprocedureoutlinedin‘ClearingtheTimers’.

2. Pressthe buttontoturnthechlorinegeneratoron.

usinG inBuilT CloCK and TiMeRs

10 11

seTTinG The ChloRine ouTPuT

Theamountofchlorinerequiredbyyourpoolisdependentonanumberoffactorsincludingthesizeofthepool,thenumberofusersandtheclimate.

Outputwillappearasapercentageonthescreenreadout,monitorthelevelaccordingtothereadingovertimewillhelpensureoptimumoutput.

ForuserswhoupgradetotheTRi-PROmodel,chlorineoutputwillbecontrolledautomatically.

TosetChlorineOutputlevels:

1. Pressthe buttontoturnthechlorinegeneratoron.

2. Pressthe / buttonstosetthedesiredoutputlevel.

PLEASENOTE:ifusingapoolcoveryouwillneedtoreducethechlorineproductionsubstantially,pleaseuseLOWmodeifyouuseacover.SimplypressLOWbutton.

ChloRine ouTPuT levels

10 11

CoRReCT seTTinGs foR youR TRi ConTRolled Pool

fre

e

Ch

lori

ne

(p

pm

)

ph

To

tal

alk

alin

ity

(pp

m)

Cal

ciu

m

hard

ne

ss

(pp

m)

Cyan

uri

c a

cid

(p

pm

)

sal

t l

eve

l (p

pm

) s

en

sors

au

stra

lian

sta

nd

ard

1–3

7.2–7.8

80–300

90–300

30–50

4000-7000

ide

al r

ead

ing/

ran

ge

1–3

7.5

80–140

90–300

504000ppm

at27ºC**

To

in

cre

ase

*

Add

chlorine

orincrease

outputof

equipm

ent

Addbuffer

orsodaash

(sodium

carbonate)

Add

sodium

bicarbonate

Add

calcium

chloride

Add

Cyanuric

acid

AddSalt

To

de

cre

ase

*

Add

muriatic

acid

Add

muriatic

acidor

dryacid

Partially

drain

&refillpool

Partially

drain

&refillpool

Partially

drain

&refillpool

fre

qu

en

cy o

f te

stin

g (i

n p

eak

se

aso

n)

Weekly

Weekly

Weekly

Weekly

Weekly

Monthly

Quarterly

Co

RR

eC

T s

eT

Tin

Gs

fo

R y

ou

R T

Ri

Co

nT

Ro

ll

ed

Po

ol

12 13

IfyouuseanautomationorcontrollersystemtocontrolyourpoolyouwillneedtoconfigureyourTRiChlorinegeneratortoallow“communication”betweenthetwo.

you must set the controller type on the TRi before making the wiring connection.

seTTinG The ConTRolleR (To be done before making a wiring connection)

1. SwitchpowertotheTRiuniton.

2. Waitforthestart-upsequencetocomplete.

3. Pressthe button.

4. Pressthe buttontoscrolldownto‘CONTROLLER’.

5. Press toenterthecontrollermenu.

6. Press / tohighlightthecontrollerbeingused.

7. Press tosavethecontrollersetting.

8. TRiwillreturntothemainmenu.

9. Press toreturntotheoperatingscreen.

ConneCTinG To a ConTRolleR

12 13

aTTenTion Jandy ‘Rev l’ oR laTeR useRs

ItiscriticalthatthecontrollersettingbesettothecorrectZodiac,JandyorPentaircontrollerdesignation.ThereareanumberofdifferentrevisionslockedintotheTRisoftware.Pleaseseetheusermanualtodeterminethemodeland/orrevisionyouareusing.Iftheincorrectsettingisselected,damagecanbecausedtotheJandyAqualinkControlUnit.

CauTion When WiRinG To a ConTRolleR

IMPORTANT

Wiringofthecontrollershouldbecompletedbyanauthorisedpoolequipmentinstaller.

Beforeanywiringconnections/disconnectionsensuremainspowerisremovedfromboththecontrollerandtheZodiacTRiunit.

Whenconnectedtoacontroller,theTRiChlorinegeneratoractsasthe‘slave’-respondingtorequests.Thismeanstimersettingsareignoredandtheoutputsettingscannotbechanged,althoughallother‘menu’functionsarestillaccessible,exceptforLOWandBOOSTmodes.

WiRinG To a ConTRolleR

ThefollowinginstructionsshouldbereadinconjunctionwiththeinstallationguideprovidedwiththeController.

1. Removesilver‘dress’coverbypressinginatthesideswhereindicatedbelowandlift.

2. Removethetwoscrewswhichattachthelowercovertothemainunit:

ConneCTinG To a ConTRolleR

14 15

ConneCTinG To a ConTRolleR

3. RemovethelowercoverfromtheTRiunit.NOTE:IfusingeitherpHupgradeorPROunit–carefullydisconnecttheribboncablefromtheTRiunit.

4. RemovethesmallwhitebungclosesttothecentreofthelowerpaneloftheTRiunit.

5. Threadthecontrollercablethroughthehole(agrommetmaybenecessarydependingonthesizeofthecablebeingused).

6. Attachacabletietothecontrollercableasshowninthediagram.Thewiringcolourcodesareoutlinedbelow:

DependingonthemakeoftheController,makethefollowingwiringconnections:

Polaris eos / Jandy / Zodiac aqualink / aqualink TRi

Greenwire(0V)to‘0V’terminalontheTRi

Redwiretothe(+V)‘POS’terminalontheTRi

Yellow/White(B)wireto‘B’terminalonTRi

Blackwire(A)to‘A’terminalonTRi

Pentair intellitouch

GREENwireto‘B’terminalonTRi

Redwireto‘POS’terminalonTRi

Yellowwireto‘A’terminalonTRi

Blackwireto‘0V’terminalonTRi

14 15

TesTinG The WiRinG ConneCTion

OnceaconnectionhasbeenmadebetweentheControllerandtheChlorinegenerator,itwillneedtobetested.

1. TurnonthepowertotheControllerandtheZodiacTRi.

2. Ifsuccessful,a‘ ’symbolwillappearinthetoprighthandcornerofthescreenafterabout20seconds.

3. Ifthecontrollerdoesnotconnect,turnpowerofftoboththedevicesandtryagain.

veRify The WiRinG ConneCTions

Toverifytheconnection:

1. SwitchtheTRiunitonandcheckthecontrollersetting(followinstructionsunder‘SETTINGCONTROLLER’.

2. Re-testtheconnection. Note:Forsafetyreasons,theZodiacTRirevertstotheOFFsettingifthecommunication

connectionislost.

ConneCTion To ConTRolleR foR Pool/sPa CoMBinaTions

ToconnectaZodiacTRiunittoPoolorSpaValves,youwillneedtomakea“splice”intothecontrollinesfromtheController,locatedinsidethecontrolleritself.

Forfurtherinformation,consulttheinstallationmanualoftheControllerbeingused.

ConneCTinG To a ConTRolleR

16 17

Ifyourpoolhasacover,youshouldsettheoutputlevelto“low”.Thisisalsoknownas“winter”mode.

Reducingyourchlorineoutputwillhelppreventdamagetoyourpool’scoverandotherequipment.

Manual seTTinG

1. ToselectLowmodepress .

Thiswilldropthechlorineoutputtoaround10%.

2. ‘Low’willappearonthescreen. Note:LoworWintermodecannotbeselectedwhenTRiisbeing

controlledbyanexternalcontroller.

auToMaTiC seTTinG

TheZodiacTRicanbeconnectedtothevalvesofanautomaticpool/spasystem.

Whentheinputfromthevalvesissetto‘Low’theTRiwillautomaticallyrevertto‘Low’modeandtheoutputwillbelockedat10%

Detailsofthewiringconnectionareoutlinedinthe‘‘ConnectiontoAutomaticPool/SpaValve”sectionofthismanual.

for users who have upgraded to the TRi-ph or TRi-PRo, the automatic ph/aCl control function is disabled when in loW mode.

seTTinG The Mode To loW: Important If usIng a pool cover

16 17

Attimesyourpoolmayrequirealargerthannormalapplicationofchlorine.TheBoostfunctionisusedtorapidlyaddchlorine.

InBOOSTor“Superchlorinate”mode,outputsettingsaretemporarilyoverriddenandthechlorinegeneratorrunsfor24hoursat100%ChlorineProduction.

In‘TIMER’mode,thecirculationpumpwillrunfor24hours,beforeautomaticallyrevertingtopreviousoutput/timersettings.

In‘MANUAL’mode,thechlorinegeneratorwillrunat100%foracumulativetotalof24hoursbeforerevertingtothepreviousoutputsetting.

NOTE:

The‘BOOST’modecannotbeengagedunderthefollowingcurcumstances:

1) IftheTRiisinthe‘OFF’operatingmode.Thechlorinatormustbe‘ON’forBOOSTtobeengaged.

2) IfyouhaveupgradedtotheTRi-PRO

3) OrfromthefrontpanelwhentheTRiisbeingcontrolledbyanexternalcontroller.

InmostcasesaBOOSTfunctioncanbesetfromthecontrollermenu.

Consultyourthirdpartycontrollermanualformoreinformation.

seTTinG The BoosT Mode

ToactivatetheBOOSTsetting:

Pressthe button.

‘BOOST’willbedisplayedonthescreenandchlorinegenerationwillcommence.

The BoosT seTTinG

18 19

TheZodiacTRichlorinegeneratorautomaticallyprovidesanumberofinbuiltwarningsthatcanhelpidentifyproblemsandoffersolutions.

ToaccesstheHELPmenu:

1. Pressthe button.

2. Usingthe / buttons,scrolltothe‘HELP/DIAG’menu.

3. Press toenterthe‘HELP/DIAG’menu.

4. Onceinthe‘HELP/DIAG’menu,usethe / buttonstoscrollto

theerror/warningthathasbeendisplayed.

5. Press .

Anumberofsuggestedsolutionsaremomentarilydisplayed,inorderofpriority.

Afterdisplaying,theTRiautomaticallyrevertsbacktothe‘HELP/DIAG’menu.

6. Toexittothedefaultoperatingscreenwait~5seconds

ORpressthe button.

helP and TRouBleshooTinG

18 19

TokeepyourTRiUnitinthebestpossibleconditionitisrecommendedregularmaintenanceshouldbeperformed.

insPeCTinG and CleaninG The eleCTRode

InareasthatexperiencecalciumhardnesstheTRielectrodewillbenefitfromcleaning.

Tocleanyourelectrode:

1. Switchoffthefilterpumpandchlorinegenerator,closenecessaryvalvesandunplugthecellterminalcap.

2. Unscrewtheretainingringandremovetheelectrode.Ifcalciumbuildupispresent,immersetheelectrodeincellcleaningsolutionwithoutimmersingtheterminals.

3. WerecommendusingZodiacSaltChlorinatorCellCleanertocleantheelectrode.Howeveryoucanmixyourownbycarefullyaddingone(1)partofHydrochloric(Muriatic)acidtoten(10)partswater.Strongersolutionswillshortenterminallife.

4. Allowthecleaningsolutiontodissolvethecalciumdepositsforabout10minutes.DisposeofthecleaningsolutionatanapprovedCouncilDepotandneverintostormwaterorsewagedrains.

6. Rinsetheelectrodeincleanwaterandre-fittheelectrodeinthecellhousing.

7. Replacethecellheadandplugassemblyandresetvalvesandswitches.TurnpumpandTRion.

8. Confirmchlorineoutputandsettingsonthepowerpack.Timersettingswillbeautomaticallyretained.

MainTenanCe

20 21

eRRoRs and WaRninGs. WhaT They Mean.

no floW

Diagnosis:Insufficientwaterflowinthecell.Thiscouldmeanthecirculationpumphasceasedtofunction,orthefilterneedscleaning.Thechlorineoutputwillbeturnedoffatthistime.

CheCK salT

Diagnosis:Saltlevelisbetween3000and4000ppm,dependingonthewatertemperature.

Alwaysmaintainasaltlevelabove4000ppm.ifyoudon’tknowwhatyoursaltlevelisorhowtotestit,consultyourlocalpoolcareprofessional.

CheCK PoWeR suPPly

Diagnosis:Therecouldbeaproblemwiththepowersupply.Turnpoweroffatthepowerpointandconsultyourlocalpoolcareprofessional.

CleaninG

Diagnosis:Thecellisintheprocessofreversingpolarity.Waitapproximately5minutesandchlorineproductionshouldresumeasnormal.

20 21

TRouBleshooTinG

additional information about this product can be found at zodiac.com.au

Forfurtherinformationandassistancepleaseconsultyourlocalpoolprofessional.

Your Local Dealer:

22 23

express Warranty*ZodiacGroupAustralia Pty Ltd (Zodiac australia)warrants that theZodiacTRiSaltwaterChlorineGeneratorwillbefreefromdefectsinmaterialsandworkmanshipfortheperiodof3yearsfromthedateofpurchase.

* The warranty applicable to commercial application is limited to 12 months from the date of installation.

Conditions

1 Thisexpresswarrantyonly applies if theProducthasbeenpurchasedfromadealerauthorisedbyZodiacAustraliatosupplyit(authorised dealer).

PurchasefromanAuthorisedDealerensuresthattheproductisagenuineZodiacproduct,thatitistheversiondesignedforAsiaPacificconditions,and that thePurchaserhasaccess toappropriate technicalknowledgeandadvice.

2 ZodiacAustralia’s liabilityunder thisexpresswarranty is limited, at itsoption,totherepairorreplacementoftheProductorthepaymentofthecostofhavingtheProductrepairedorreplaced.

3 Thisexpresswarrantydoesnotapplyinthefollowingcircumstances:

(a)if the Product has not been installed in accordancewithZodiac’sinstallationinstructions;

(b)iftheProducthasbeenmodifiedotherthanasauthorisedbyZodiacAustraliaorifacomponentparthasbeenreplacedbyapartthatisnotagenuineZodiacproduct;

(c)if a defect results fromuse of the Product outside recommendedoperatingconditions;or

(d)if a defect results from damage (including damage to any internalelectronics)causedbyapowersurgeorlightningstrike.

Zodiac chlorinators are designed and tested in accordance withInternational Standard EN 61000-6-1 immunitymeasurements. Theyaredesignedtotolerateminorfluctuations(2000volts)inpowersupplythatcanbereasonablyexpectedtooccurintheenergygrid.Theywillnottoleratepowersurgesoutsidetheselimitsnorwilltheywithstandlightningstrikes.

ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees

22 23

ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees

4 Withoutlimiting3above,productssoldbyZodiacAustraliaaredesignedforusewithswimmingpoolwaterbalancedinaccordancewithAustralianStandardAS3633-1989withapHrangeof7.0-7.8.Maximumchlorinereadingsshouldnotexceed4ppm.Wherepoolwaterisnotmaintainedwithintheseparameters,ZodiacAustraliawillnotberesponsibleunderthisexpresswarrantyforanyresultingdamage,includingdamagecausedbycorrosion,scalingorstressloading.

5 Replacementpartssuppliedunderthisexpresswarrantyarewarrantedtobefreefromdefectsinmaterialsandworkmanshipfortheremainderofthewarrantyperiodorfor12monthsfromthesupplyofthereplacement,whicheverislonger.

6 WarrantyclaimsrelatingtoreplacementoftheelectrodesforLMseries,Cseries,DuoClearandDserieschlorinatorsaresubjecttothefollowingpro-ratapricingprocedure.ThePurchasermustpayforthereplacementelectrodeaproportionofthecostequaltothatproportionofthewarrantyperiod duringwhich theoriginal electrode functioned effectively. Thewarrantyperiodforthereplacementelectrodeistheremainderofthewarrantyperiodfortheoriginalelectrodeor12monthsfromthesupplyofthereplacement,whicheverislonger.ThePurchasermustpayfullcostforanyreplacementelectrodesafterthefirstreplacement.

Product warranty registration

7 PurchasersshouldregistertheirProductsassoonasconvenientlypossibleafterpurchasebycompletingaProductWarrantyRegistrationFormandpostingittoZodiacAustraliaattheaddressshownontheFormorbyregisteringonlineatwww.zodiac.com.au.

8 Productregistrationmustoccur,andproofofpurchasemustbereceivedbyZodiacAustralia,priortoanywarrantyworkbeingapproved.Whereapplicable,aserialnumber,installationdateandnameofinstallerisrequiredaspartoftheregistrationprocess.

24 25

ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees

how to make a warranty claim

9 ThePurchasermusttelephoneoremailZodiacAustraliaCustomerServiceandobtainawarrantyIDnumberforthewarrantyclaim.

Contactdetailsare:

Zodiac Group australia Pty ltd 219WoodparkRoadSmithfieldNSW2164

Customer service Telephone:1800688552Emailaddress:aftersales@zodiac.com

10ZodiacAustralia reserves the right to determine, in relation to eachwarrantyclaim,whethertheProductshouldbereturnedtotheAuthorisedDealerat theaddresswhere thePurchaserpurchased theProductorwhetherwarrantyservicewillbeprovidedinthefield,repairedataZodiacworkshoporatthepremisesofanauthorizedZodiacwarrantyagent.

11 IfitisnecessaryforthePurchasertoincurfreightchargesinmakingavalidclaimunderthiswarranty,ZodiacAustraliawillreimbursethePurchaserforchargesreasonablyincurreduponproofofthecharges.

24 25

ZodiaC ausTRalia - exPRess WaRRanTy and GuaRanTees

additional guarantees, rights and remediesaustralian Purchasers - Guarantees under the australian Consumer law

12Thebenefitsofthisexpresswarrantyareinadditiontootherguarantees,rights and remediesAustralian consumers have under theAustralianConsumerLaw.

13ZodiacAustraliaproductscomewithguaranteesthatcannotbeexcludedundertheAustralianConsumerLaw.Youareentitledtoareplacementorrefundforamajorfailureandforcompensationforanyotherreasonablyforeseeablelossordamage.Youarealsoentitledtohavethegoodsrepairedorreplacedifthegoodsfailtobeofacceptablequalityandthefailuredoesnotamounttoamajorfailure.

Purchasers in other Countries

14ThelawsandregulationsofothercountriesmayconferonPurchasersinthosecountriesadditionalrightsandremedies.Totheextentthattheycannotbeexcludedormodified,Purchasershavethebenefitsofthoserightsandremediesinadditiontothebenefitsofthisexpresswarranty.Tothefullextentthatitispermissibletodoso,thoseadditionalrightsandremediesareexcludedormodifiedsoastobeconsistentwithZodiacAustralia’sexpresswarranty.

inConsisTenCy WiTh WaRRanTy sTaTeMenTs in PRoduCT Manuals oR oTheR doCuMenTs aCCoMPanyinG PRoduCTs

Ifanywarrantystatements inaZodiacAustraliaproductmanualorotherdocumentareinconsistentwiththeaboveExpressWarrantyandGuarantees,theaboveoverridesandreplacestheinconsistentstatements.

ZodiacisaregisteredtrademarkofZodiacGroupAustraliaPtyLtdABN87002641965

ZodiaC CusToMeR seRviCe CenTRe

ZodiacGroupAustralia:

219WoodparkRd,Smithfield,NSW2164Australia

Tel:1800688552Fax:1300781688

Email:aftersales@zodiac.com.auwww.zodiac.com.au

Duetoconstantdevelopmentsandimprovements,specificationsmaychangewithoutnotice.

Improperusecouldaffectperformanceandvoidwarranty.

©CopyrightZodiacAustraliaLtd2013

W176781REV.A

pH Upgrade

InstrUctIon ManUal and

Warranty card

1

part: Qty: description:

1. 1 TRi-pHModule(ifpurchasedseparately)2. 1 Holesaw3. 1 Tubing4. 1 PODassembly5. 1 pHsensor6. 1 pHsensorcable7. 1 Sensorcalibrationfluid8. 1 AntiFumeCap5ltand15/20lt9. 1 CeramicWeight10. 1 Weightbarbfitting(forendoftube)

WelcoMe to ZodIactHIs KIt contaIns:

9. 10.

1.

4. 5.

6.

7.

8.

2.

3.

1

WelcoMe to ZodIactHIs KIt contaIns:

CongratulationsonyourpurchaseofaproductfromtheZodiacrangeofpoolcareproducts.Zodiacproductsaredesignedtoletyouspendmoretimeenjoyingyourpoolandlessonmaintenance.

IMportant InforMatIon

YOUMUSTREADTHISINFORMATIONBEFOREINSTALLATION.ALWAYSREADTHELABELANDOPERATIONMANUALBEFOREUSING.PLEASEKEEPYOURMANUALASITCONTAINSYOURWARRANTY

AtZodiac,wetakesafetyseriously.Alwaysexercisecautionwhenusingelectricalappliancesandfollowtheinstructions.Failuretodosocouldresultinpermanentinjury,electrocutionordrowning.

general WarnIngs

Zodiacsaltwaterchlorinegeneratorsaredesignedfordomesticswimmingpooluseonly.Contraryusecouldaffectperformanceandvoidwarranty.

Operatingachlorinegeneratorwithoutwaterflowingthroughthecellmaycauseabuildupofflammablegases,resultinginfireorexplosion.

Keepequipmentoutofreachofchildren.

Adamagedsupplycordshouldonlybereplacedbythemanufacturer,authorizedserviceagentorelectrician.

Wheninstallingandusingthiselectricalequipment,alwaysfollowbasicsafetyprecautions.

Beforeperforminginstallation,disconnectallpower.

Forswimmingpools,Australianstandardsrecommendaminimumof1Part

PerMillion(ppm)offreeavailablechlorinemustbemaintainedatalltimes.

ServicetoZodiacequipmentshouldonlybecarriedoutbyqualifiedandauthorizedpoolprofessionals.

2 3

ZodIac BelIeves In safety fIrst IMportant tHIngs to reMeMBer

cHIld safety

Childrenshouldnotbeallowedtooperateorperformmaintenanceonthisproduct.

Noone,particularlychildren,shouldsit,step,lean,orclimbonanyofyourpool’soperationalsystem.

Intheinterestsofchildsafety,allcomponentsofapool’soperationalsystemshouldbelocatedatleast3.5metresawayfromthepool.

electrIcal HaZard

Toavoidaccidentalcontactwithlawnmowersandhedgetrimmers,powercordsshouldremainwithinsightandabovegroundatalltimes.

TheZodiacTRiPowerpackmustnotcomeintocontactwithwaterandmustbeinstalledatleast3.5metresfromtheinsidewallofyourswimmingpool.

Shouldalackofwaterbedetected,theunit’selectronicflowswitchisdesignedtoturnoffthesystem.Interferingwiththeelectronicflowswitchcouldresultinpersonalinjuryand/ordamagetothecell.

Onepumpperelectricalsocketonly(noancillaryequipmentshouldbeconnectedtothesameoutlet).

Thisapplianceisnotintendedforusebypersons(includingchildren)withreducedphysical,sensoryormentalcapabilities,orlackofexperienceandknowledge,unlesstheyhavebeengivensupervisionorinstructionconcerninguseoftheappliancebyapersonresponsiblefortheirsafety.

Childrenshouldbesupervisedtoensurethattheydonotplaywiththeappliance.

TheinstallationofthechlorinatorshouldbecarriedoutbyaqualifiedpersoninaccordancewiththeAustralianwiringrulesAS/NZS3000.

Thechlorinatorpowerpackshouldbelocatedinthecorrectpoolzoneandconnectedtosupplyviaapoweroutletthatisprotectedbyaresidualcurrentdevice(RCD)havingaratedresidualoperatingcurrentnotexceeding30mA.ThepoweroutletshouldhaveadegreeofprotectionsuitableforthepoolzoneEnsurethatequipotentialbondingofallpartsofthepoolinstallationiscarriedout.

2 3

ZodIac BelIeves In safety fIrst IMportant tHIngs to reMeMBer

ThereareanumberofveryimportantthingstorememberwhensettingupandmaintainyourTRi-pH.

1. ItisabsolutelyessentialtohavethepoolwateringoodbalancebeforeturningtheTRi-pHonsoensurethatthepoolwateriscorrectlybalanced(seepage10oftheTRiownersmanualforcompletelist).

2. DoNOTunderanycircumstancesstoretheacidcontainerunderneaththepowerpackunit.RisingacidfumeswillcauseconsiderabledamagetotheunitandthiswillNOTbecoveredunderwarranty

3. Storeyouracidcontainersafelyandoutofreachofchildren.Iftheacidcontainerisstoredinashedalwaysensurethereisadequateventilationforfumestoescape

4. DoNOTdilutethepoolacid.TRiisahighperformance,highdurabilityproductandisdesignedtousestraightacidfromthecontainer,soyoudonothavetodiluteit.

5. Alwayshandlethesensorswithcareandnevertouchthesensortipwithyourfingers.Ifthesensorneedscleaningusesoapandwaterandcleanthoroughly

6. IfinstallingTRi-pHonanewpoolyoumayfindthatahigherthanusualaciddemandisexpected.Thiswillsettleafterafewweekssopleasemonitoritsneedsduringthis‘settling’phase

4 5

InstallIng tHe pH sensor pod

ThefollowingstepswillhelpyougetupandrunningwithyournewZodiacTRipHUpgradeModule.IfyoupurchaseyourZodiacTRipHasacompleteunitgostraighttosection-InstallingSensors.

If yoU Have pUrcHased tHe trI pH Upgrade:

HowtoinstalltheTRipHupgradeunit:

1. Turnmainspoweroffandremovetheexistingtopcover.

2. Unscrewthebottom2screwsonthemainbodypanelandremovethebottomcover.

3. PlugtheribboncablefromthepHunitintothepHconnectorontheTRiunit.

4. Refitthe2removedscrewsaswellasthetopcoverwiththenewpHunitinstalled.

QUIcK start InstallatIon gUIde

4 5

InstallIng tHe pH sensor pod

Installing the pod and sensorTRisensorPODintegratesintoasimpleunit,apHsensorandapHcorrectivesolutiononewayvalve.ThesensorPODmustbepositionedafterfiltrationsystemandbeforeTRicell(andafteranyheatingsystem).SensorPODmustalwaysbepositionedontoahorizontalpipesothatthepHsensorisvertical(45°maximumtolerance).Warning: never store the acid container underneath or near the tri-pH power pack

QUIcK start InstallatIon gUIde

6 7

preparIng pH sensor fIttIng tHe acId delIvery systeM

1. Identifyastraightsectionofhorizontalpipeofappropriatelengthafterthefilterbutbeforethesaltcell(30cmisrecommended).

2. DisassemblesensorPODtogetlowerpartofPODclampwith2holes(picture1).

3. PlacethelowerpartofPODclampupsidedownintopositionontheselectedlengthofpiping

4. Nowmarkthelocationofthe2holestobemadeintopipingusingapencilormarker(picture2).

5. Drillthe2holesusingtheprovidedholesaw.Ensurethatholesareperfectlysmootharoundtheedges(picture3).

6. PositiontheupperpartofPODclampbyslidingitintothe2previouslydrilledholes(picture4).

Warning: arrows on upper part of pod clamp indicate direction of water flow

7. InterlockthelowerpartofPODclampontotheupperpartalreadyinplaceonpiping.(ifusing40mmpipeusethespacerprovided)

8. FitthePODcapontopofupperPODclamp,re-fitlockingringandtightenfirmlyusingprovidedtool.

9. InstallthepHsensorbyfirmlyscrewingintothePODcap.

10.ConnectthesensorswiththeprovidedcabletotheappropriatesocketsontheTRipowerpack.

2

1

Ensureflowarrowsareinthecorrect

4

3

Smoothedges

SensorfittedinPOD

Injectiontubefittedtoonewayvalve

6 7

preparIng pH sensor

2. Removethesmallfacepanelthatcoverstheperistalticpump

3. Thesuctiontubeisconnectedtothelefthandsideoftheperistalticpump.

4. Usealengthoftubelongenoughtoreachfromtheliquidcontainertothecontrolboxandfeedthetubethroughtheblackrubbergrommetinthe‘anti-fume’cap(2sizesareincluded5ltand15/20lt).

5. Oncethecapisonthetube,nowfitthesmallceramicweightonthesuctiontubeandthenfitthesmallbluebarbfittingtotheendofthetubetopreventtheweightfromfallingoff.(seepictureA)

6. Nowconnecttheinjectiontubingtotheinjectionside(righthand)oftheperistalticpump

7. FirstlyremovethesmallscrewfittingandslideitontothetubingthenfittheendofthetubeontotheonewayvalvelocatedinthesensorPODandscrewdownthefittinglockingitintoposition(thisistheinjectionpointforthesolutionbeingdelivered)(seepictureB)

fIttIng tHe acId delIvery systeM

now the pod is in place and the sensor is connected it is time to connect the suction and injection tubes

1. Toconnectthesuctionandinjectiontubesplease‘soften’theendsofthetubingbyimmersinginwarmwaterforafewminutes.

A

B

8 9

fIttIng tHe acId delIvery systeM testIng / prIMIng tHe acId pUMp

8. Onceallconnectionsaremadeplacethesuctionlineintothecontainerandscrewtheantifumecapdownintoposition.(seepictureC)

please taKe note of tHese IMportant poInts WHen connectIng pH control

• only use straight hydrochloric (muriatic) acid, do not dilute or use any other type of acid.

• do not store the acid container in the filtration shed unless there is adequate ventilation as the fumes will corrode any items in the shed - including your pool care equipment. store your acid in a secure location away from any hazards

• do not store the acid container directly under or near the tri power pack.

failing to comply with this could void your warranty.

C

8 9

Afterinstallationit’srecommendedtheacidpumpbetestedandtheacidpump‘primed’.

WARNING!Beforetestingthepump,ensureallacidsupplyanddeliveryconnectionsaresecure.Alwaysuseappropriatesafetyequipmentwhenhandlingacid.

TotesttheAcidPump:

1. Pressthe button.

2. Press / buttonstomovearrowto‘pHSETUP’.

3. Press toenterthe‘pHSETUP’menu.

4. Usethe / buttonstohighlight‘TESTACID’andpress to

entertestacidmenu.

5. Awarningwillmomentarilybedisplayed,thenpress againtostartthepump.

Theacidpumpwillrunforapproximately10minutesandautomaticallyswitchoff.(Ifthepumpneedstobeturnedoffimmediately,pressthe

button)

NOTE:Steps1to5mayrequirerepeatingseveraltimesdependingonthelengthoftheacidsupplytube.

fIttIng tHe acId delIvery systeM testIng / prIMIng tHe acId pUMp

10 11

ThefollowinginformationaboutpHiscriticaltothesuccessfuloperationofyourswimmingpool.

Foradviceandsupplyofthecorrectproducts,consultyourlocalpoolcareprofessional.

preparIng tHe pool

TheTRi-pHunitisdesignedtomaintainthepHofthepool.

Byensuringthatthepooliscorrectlybalancedattheoutsetwilldecreasethechanceofproblems,duringthefirstdaysofoperation.

pH levels

IdealpHrangeformostpoolsis7.2–7.6

AllchemicalbalancesinthepoolareaffectedbypH,makingitthesinglemostimportantelementofswimmingpoolchemistry.

1. TolowerpHlevelusedilutedhydrochloricacidorphosphoricacid(thiswillbedoneautomaticallybytheTRi-pHonceconnected).

2. ToraisepH.Usesodaash.

total alKalInIty (ta) levels

IdealTAlevelrange:80-140partspermillion(PPM)

TotalAlkalinityisameasureofalkalinechemicalsinyourpoolandcanbeusedasa“buffer”tocontrolpHlevels.IfTAlevelsaretoolow,itmaystainpoolsurfacesandmakecontrollingpHlevelsdifficult.

IfTAlevelsaretoohigh,scalingmaybeevidentonpoolwallsandinthechlorinatorcells.

1. Toraisetotalalkalinity.AddpHbufferorstabilizer,accordingtomanufacturer’sinstructions.

2. Tolowertotalalkalinity.Addapproximately400mlofhydrochloricaciddaily.

3. Whentotalalkalinityhasstabilizedwithintheprescribedidealrange,youmayneedtoadjustthepool’spH.

pH controlpH control

10 11

cHlorIne levels

Idealchlorinelevelrange:1-3partspermillion(PPM).

PriortostartingtheTRi-pHthechlorinelevelcanberaisedusingeitherliquidorgranulatedchlorine.

salt levels

IdealSaltlevelrange:3000–5000partspermillion(PPM).

Efficientandcorrectoperationoftheelectrolyticcellrequiresasufficientamountofsaltinthewater.

Notenoughsaltmaycauseareducedchlorineoutputlevelandareducedlifeofthecell.

Toomuchsaltwillcauseeyeirritationandasaltytasteinthepoolwater.

filter / skimmer

Inadditiontothepoolchemistrybeingimportant,theconditionofthefiltrationsystemandskimmerbasketsmustbeassessed.Ifrequired,backwashthefilterandremovedebrisfromthepoolskimmerbasket(s).

aUtoMatIc detectIon

WhentheZodiacTRiUnitautomaticallydetectsthepresenceofaTRipHmoduleitdisplaysthepool’spHsetpoint.

1. Themessage‘pHCONTROL’appearsonthethirdlineofthescreen.

2. Thepool’spH“setpoint”isdisplayedatthebottomofthescreen. NOTE:Fromfactory,theaciddeliveryisdisabledandthepHsetpointwillbedisplayedas“----“.

Referto‘EnablinganddisablingtheAcidPump’formoreinformation.Whentheaciddeliveryisenabled,thepHsetpointisdisplayedatthebottomofthescreen.

pH controlpH control

12 13

WithpHsensorandaciddeliverycomponentssuccessfullysetup,theTRiunitneedstobecalibratedandsetupforpHcontrol.EnsurethatmainspowerissuppliedtotheTRi,turnthepoolpumpoffandisolatethepoolwatersothepHsensorcanbesafelyremoved.

1. RemovethepHsensorandcleanifnecessaryusingsoapywater.(Avoidtouchingtheglasstipofthesensor).Rinseoffwithfreshwater.

2. PlacethepHsensorinasampleofpHcalibrationsolutionwithapHlevelof7.5.

3. Leavethesensorimmersedinthesolutionforaminimumof30secondstosettle.

4. Fromthedefaultoperatingscreen,press .

5. Usethe / buttonstohighlight‘pHSETUP’,thenpress .

6. Usethe /buttonstohighlight‘CALIBRATEpH’,thenpress .

7. Observethe‘CURRENT’pHreading.Ifthereadingisabove8.2orbelow6.4,theremaybeaproblemwiththesensororpHunit.DONOTCONTINUEandrefertoyourlocalpoolprofessionalforassistance.

8. IftheCURRENTreadingiswithintheabovelimits,pressthe buttontobegincalibration.

9. Whencalibrationiscomplete,notethenewpHreading.Ifthereadingisnot7.5,repeattheprevious5steps.(IfthecurrentpHstilldoesn’tread7.5refertoyourlocalpoolprofessionalforassistance.)

10.Pressthe buttontwiceorwait30secondsandtheTRiunitwill

returntothedefaultoperatingscreen.

pH set poInt

12 13

pH set poInt

ThedefaultpHsettingofyourZodiacTRiis7.2.Thiscanbechangedaccordingtoyourpool’srequirements.

TochangethepHsetpoint:

1. CalibratethepHsensor.

2. Fromthedefaultoperatingscreen,press .

3. Usethe / buttonstohighlight‘pHSETUP’,thenpress .

4. Usethe / buttonstohighlight‘pHSETPOINT’,thenpress .

5. Usethe / buttonsuntilthedesired“setpoint”isachieved

Thenpressthe tosavethedesiredsetpointthenpress twice

togobacktooperatingscreenorwaitforoneminute.

14 15

pH set poInt pH set poInt

settIng tHe pool sIZe

this setting controls the maximum amount of acid which is delivered to the pool daily. your unit comes factory set on pool size 2.

the recommended settings for various size pools are as follows:

1: Forsmallpoolsupto40000litres

2: Formediumpools40000to60000litres

3: Forlargepools60000to100000litres

4: Foroversizepoolsabove100000litres

Theabovesettingsareaguidelineonly.Itisrecommendedthatalowersettingbeselectedinitially–thissettingcanbeincreasedatalatertimeifinsufficientacidisbeingdosedtomaintainthecorrectpHlevel.

Tosetthepoolsize,followtheprocedurebelow:

1. Fromthedefaultoperatingscreen,press .

2. Usethe / buttonstohighlight‘pHSETUP’,thenpress .

3. Usethe / buttonstohighlight‘POOLSIZE,thenpress .

4. Usethe / buttonstoselectthepoolsizetothedesiredvalue.

Thenpress tosave.

5. Nowpress twicetoreturntothemainoperatingscreen.

(Orthiswillautomaticallyhappenafteroneminute)

NOTE: Acid is dosed into the pool while the chlorinator and filtration system are running.

14 15

pH set poInt pH set poInt

WarnIng! It is advised that the pool size be set as low as possible to avoid overdosing acid into the pool.

UsIng pH control

TheTRi-pHisnowreadyforusewithautomaticpHcontrol.

1. Set‘ON’and‘OFF’times.

2. Selectdesiredchlorineoutputlevel.

3. EnabletheAcidPump(RefertoEnablinganddisablingtheAcidPump.)

TheTRiunitwillnowautomaticallymaintainthepHlevelofthepool.

16 17

AlthoughautomaticpHcontrolreducestheneedforregulartesting,therearestillanumberofcheckstoensurethesafeoperationofthesystemandapleasantswimmingexperience.

always check:

Acidsupplylevels.

TotalAlkalinity.

TheaccuracyofthepHsensorbymanuallycheckingthepHlevel.

ThatthepHsensoriscleanedandre-calibrated.

acid pump and feed line Maintenance

1. Lubricatethepumpsqueezetubeevery6months.Uselubricantrecommendedbyyourlocalpoolcareprofessional

2. Thepumpsqueezetubeisawearingitemandmayneedtobereplacedduringthelifeoftheproduct,regularcheckingwillletyouknowwhenthisisneeded.

please note: peristaltic pump and associated fittings, tubing etc are covered by a 1 year limited* warranty only

3. Theacidinjectionpointandfeedlinesshouldbecheckedforblockagesandbecleanedasrequired.Alwaysensureyouwearappropriatesafetyequipmentwhenhandlingacid

*seewarrantytermsandconditionsattheendofthismanual

adjUstIng total alKalInIty (ta) regUlar cHecK Ups

16 17

Asacidisaddedautomaticallyovertime,totalalkalinitylevelswilldecreaseandmayresultininconsistentpHlevels.

Itmaybenecessarytoadda“buffer”elementtothewaterinyourpool.

Asitisnotrecommendedtoaddacidafteraddinga“buffer”,temporarilydisabletheacidpump(refertoEnablinganddisablingtheacidpump).

enaBlIng and dIsaBlIng tHe acId pUMp.

Intheinterestsofsafety,theZodiacTRi-pHisshippedwiththeacidpumpdisabled.

WhenaTRi-pHisconnected,theacidpumpisprogrammedtobeginoperationafterapproximately8hoursofbeingactivated.Thiscanbeoverriddenbydisablingtheacidpump.

Whentheacidpumpisdisabled,thesetpointreadingwillbereplacedwith“---“untiltheacidpumpisre-enabled.

After8hours,thedeactivatedpumpwillautomaticallyre-enableitself.

to enable the acid pump manually:

1. Fromthedefaultoperatingscreen.

2. Pressthe button.

3. Press / buttonstomovearrowto‘pHSETUP’.

4. Press toenterthepHmenu.

5. Usethe / buttonstohighlight‘ACIDPAUSED’

(OR‘ACIDENABLED’).

6. Press totogglebetween‘ACIDENABLED’and‘ACIDPAUSED’.

7. Oncetheappropriateselectionhasbeenmade,press twiceorwait

~60secondsfortheTRitorevertbacktothedefaultoperatingscreen.

adjUstIng total alKalInIty (ta) regUlar cHecK Ups

18 19

WhenusingautomaticpHcontrol,therequirementforregularpoolchemistrychecksislowered.Itishowever,necessarytoregularlycheckanumberofcriticalthingstoensuresafeandcorrectoperationofthesystem:

cleanIng tHe pH sensor

Whencleaningthesensoravoidusingsolventssuchasacetone.Alwayscalibrateaftercleaning.

Tocleanthesensor:

Iftheelectrodehasbecomecoatedwithoilorgrease,carefullywashtheelectrodeunderwarmtapwaterusingdish-washingdetergent.Rinsethesensorthoroughlywithcleantapwater.

Iftheaboveproceduredoesnotwork,soakthesensorinadilutedhydrochloricacid(HCL)solutionfor10seconds.

Thiscanbepurchasedfromyourlocalpoolprofessionalormadebycarefullyaddingone(1)partofHydrochloric(Muriatic)acidtoten(10)partswaterinasuitablecontainer.ALWAYSADDACIDTOTHEWATER.Aftersoaking,rinsethesensorthoroughlyincleantapwaterandrecalibratebeforeuse.

Iftheabovetwoproceduresfailtorestorethesensor,thesensorshouldbereplaced.

errors and WarnIngs. WHat tHey Mean.

18 19

errors and WarnIngs. WHat tHey Mean.

pH loW

Diagnosis:thepHLevelinthepoolhasdroppedtoofarbelowthesetpoint.ThiscouldindicatethePOOLSIZEsettingistoohigh,causingacidtooverdoseorthepHsensorisfaultyorneedscalibrationand/orcleaning.Manuallytestthepool’spHbeforefurtherinvestigation,ifallequipmentisoperatingfinethenadjustyourpoolsettingtoalowervalue.

pH error

Diagnosis:theacidpumphascompleteditsdosingcycleswithoutreachingthesetpoint.Thiscouldindicatetheacidsupplyisempty,thepHsensorisfaultyorneedingcalibration/cleaning,thePoolsizeissettoolowortheacidpumpisfaulty.Toclearthiserrorpleaseholddowntheselectbuttonfor5seconds(theTRimustbeon).

additional information about this product can be found at zodiac.com.au

Forfurtherinformationandassistancepleaseconsultyourlocalpoolprofessional.

your local dealer:

20 21

express Warranty and gUarantees notes

express WarrantyZodiac GroupAustralia Pty Ltd (Zodiac australia)warrants that theTRi-pHChlorinatorwill be free fromdefects inmaterialsandworkmanship.TheCellandPowerPackiswarrantedfortheperiodofthree(3)years,ifusedinadomestic/residentialpool.ThePeristalticpump,sensorsandotherextraneousequipmentareconditionallywarrantedfortheperiodoftwelve(12)months,ifusedinadomestic/residentialpool.conditions1 ThisexpresswarrantyonlyappliesiftheProducthasbeen

purchasedfromadealerauthorisedbyZodiacAustraliatosupplyit(authorised dealer).Purchase from anAuthorisedDealer ensures that theproductisagenuineZodiacproduct,thatitistheversiondesignedforAsiaPacificconditions,andthatthePurchaserhasaccesstoappropriatetechnicalknowledgeandadvice.

2 ZodiacAustralia’sliabilityunderthisexpresswarrantyislimited,atitsoption,totherepairorreplacementoftheProductorthepaymentofthecostofhavingtheProductrepairedorreplaced.

3 This expresswarranty does not apply in the followingcircumstances:(a)iftheProducthasnotbeeninstalledinaccordancewith

Zodiac’sinstallationinstructions;(b)if the Product has been modified other than as

authorisedbyZodiacAustraliaorifacomponentparthasbeenreplacedbyapartthatisnotagenuineZodiacproduct;

(c)if a defect results fromuse of the Product outsiderecommendedoperatingconditions;or

(d)ifadefectresultsfromdamage(includingdamagetoanyinternalelectronics)causedbyapowersurgeorlightningstrike.

Zodiacchlorinatorsaredesignedandtestedinaccordancewith International Standard EN 61000-6-1 immunitymeasurements. They are designed to tolerateminorfluctuations (2000 volts) in power supply that can bereasonablyexpectedtooccur intheenergygrid. Theywillnottoleratepowersurgesoutsidethese limitsnorwilltheywithstandlightningstrikes.

4 Withoutlimiting3above,productssoldbyZodiacAustraliaaredesignedforusewithswimmingpoolwaterbalancedinaccordancewithAustralianStandardAS3633-1989withapHrangeof7.0-7.8.Maximumchlorinereadingsshouldnotexceed4ppm.Wherepoolwaterisnotmaintainedwithin these parameters, ZodiacAustraliawill not beresponsibleunderthisexpresswarrantyforanyresultingdamage,includingdamagecausedbycorrosion,scalingorstressloading.

5 Replacementpartssuppliedunderthisexpresswarrantyarewarrantedtobe free fromdefects inmaterialsandworkmanshipfortheremainderofthewarrantyperiodor for 12months from the supply of the replacement,whicheverislonger.

6 Warrantyclaimsrelatingtoreplacementoftheelectrodesfor LM series, C series, Duo Clear and D serieschlorinatorsaresubjecttothefollowingpro-ratapricingprocedure.ThePurchasermustpayforthereplacementelectrodeaproportionofthecostequaltothatproportionof the warranty period during which the originalelectrode functioned effectively. Thewarranty periodfor the replacement electrode is the remainder of thewarrantyperiodfortheoriginalelectrodeor12monthsfromthesupplyofthereplacement,whicheverislonger.The Purchasermust pay full cost for any replacementelectrodesafterthefirstreplacement.

product warranty registration7 Purchasers should register their Products as soon as

conveniently possible after purchase by completing aProductWarrantyRegistration Form and posting it toZodiacAustraliaattheaddressshownontheFormorbyregisteringonlineatwww.zodiac.com.au.

8 Productregistrationmustoccur,andproofofpurchasemustbereceivedbyZodiacAustralia,priortoanywarrantyworkbeingapproved.Whereapplicable,aserialnumber,installationdateandnameofinstallerisrequiredaspartoftheregistrationprocess.

How to make a warranty claim9 ThePurchasermusttelephoneoremailZodiacAustralia

CustomerServiceandobtainawarrantyIDnumberforthewarrantyclaim.Contactdetailsare:Zodiac group australia pty ltd 219WoodparkRoadSmithfieldNSW2164customer service Telephone:1800688552Emailaddress:aftersales@zodiac.com.au

10ZodiacAustraliareservestherighttodetermine,inrelationtoeachwarrantyclaim,whethertheProductshouldbereturnedtotheAuthorisedDealerattheaddresswherethePurchaserpurchasedtheProductorwhetherwarrantyservicewillbeprovidedinthefield,repairedataZodiacworkshopor at the premises of an authorizedZodiacwarrantyagent.

11IfitisnecessaryforthePurchasertoincurfreightchargesinmakingavalidclaimunderthiswarranty,ZodiacAustraliawill reimburse the Purchaser for charges reasonablyincurreduponproofofthecharges.

additional guarantees, rights and remediesaustralian purchasers - guarantees under the australian consumer law12The benefits of this expresswarranty are in addition

to other guarantees, rights and remediesAustralianconsumershaveundertheAustralianConsumerLaw.

13ZodiacAustralia products comewith guarantees thatcannotbeexcludedundertheAustralianConsumerLaw.Youareentitledtoareplacementorrefundforamajorfailure and for compensation for any other reasonablyforeseeablelossordamage.Youarealsoentitledtohavethegoodsrepairedorreplacedifthegoodsfailtobeofacceptablequalityandthefailuredoesnotamounttoamajorfailure.

purchasers in other countries14Thelawsandregulationsofothercountriesmayconfer

on Purchasers in those countries additional rights andremedies. To theextent that they cannotbeexcludedormodified,Purchasershavethebenefitsofthoserightsandremediesinadditiontothebenefitsofthisexpresswarranty.Tothefullextentthat it ispermissibletodoso,thoseadditionalrightsandremediesareexcludedormodifiedsoas tobeconsistentwithZodiacAustralia’sexpresswarranty.

I n con s I s t e n c y W I t H Wa r r a n t y stateMents In prodUct ManUals or otHer docUMents accoMpanyIng prodUctsIf anywarranty statements in aZodiacAustralia productmanualorotherdocumentareinconsistentwiththeaboveExpressWarrantyandGuarantees,theaboveoverridesandreplacestheinconsistentstatements.

20 21

express Warranty and gUarantees

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

notes

W176831REVA

Zodiac customer service centre

ZodiacGroupAustralia:

219WoodparkRd,Smithfield,

NSW2164Australia

Tel:1800688552

Fax:1300781688

Email:aftersales@zodiac.com.au

www.zodiac.com.au

Duetoconstantdevelopmentsandimprovements,specificationsmaychangewithoutnotice.

Improperusecouldaffectperformanceandvoidwarranty.

©CopyrightZodiacAustraliaLtd2013

top related