type i compact orifice plate.pdf · 2010-08-17 · rosemount inc. certifies this drawing is in...
Post on 17-Jun-2018
217 Views
Preview:
TRANSCRIPT
®
SEE TABLE 1B
(TYP) EXCEPT B31.1 STYLE
8.25 (210) BOTH OPEN MAX.7.75 (197) BOTH CLOSED MIN.
HIGH PRESSUREINSTRUMENTVALVE
EQUALIZER VALVE
LOWPRESSUREINSTRUMENT VALVE
TYPICAL EXCEPT B31.1 STYLE
6.25 (159) OPEN MAX. 6.00 (152) CLOSED MIN.
1.00 (TYP)
5.50 (140)(TYP) ALL
LINE SIZES
'A'
FLOW
3X VALVE
3X ROLL PIN
2X 1/4 NPT VENT
405P OR405C
405P SHOWN 405C SHOWN
NOTE: DIMENSIONS 'A' & ' B'ARE TYPICAL TO ALL CONNECTION TYPESSHOWN FOR BOTH 405C & 405P MODELS
TABLE 1 *LINE SIZE DIAMETER 'B'
1/2" 1.38 (35)1" 2.00 (51)
1-1/2" 2.88 (73)2" 3.62 (92)3" 5.00 (127)4" 6.19 (157)5" 7.31 (186)6" 8.50 (216)8" 10.62 (270)10" 12.75 (324)12" 15.00 (381)
DR. 6/12/03
T.ORLESKIE 8/19/03
jpaylor
SIZE
SCALE: NONE
C
TITLE
00405-1001
BOULDER, COLORADO
DRAWING NO.
REVISIONS
AH
REV
CHG. A DIM./ADD 5, 10 & 12" LINES/COMBINE WITH 00405-1011,21 & 40-990000
DESCRIPTION CHG.NO.
DSI1000958 CTO
APP'D
8/16/07
DATE
APPROVAL
SPECIALS
TAGGING
DRAWING
*ALL DIMENSIONS ARE NOMINALAND ARE FOR REFERENCE ONLY
*UNLESS OTHERWISE SPECIFIEDDIMENSIONS IN INCHES (MM)
TYPE I
SHEET 1 OF 6
DIMENSIONAL DRAWING MODEL 405 COMPACT ORIFICE PLATE/FLOWMETER
(3051SFC & 3095MFC)
®
DIRECT MOUNT
DIRECT MOUNTCOPLANAR OR TRADITIONAL
MOUNT ADAPTER
7.70 (196) FOR 30516.27 (159) FOR 3095
DIRECT MOUNT
.70 (18)
8.54 (216) FOR 30517.10 (180) FOR 3095
DIRECT MOUNTCOPLANAR OR TRADITIONAL
MOUNT ADAPTER
NOTES:
1. ROSEMOUNT INC. CERTIFIES THIS DRAWING IS IN ACCORDANCE WITH ROSEMOUNT ENGINEERING SPECIFICATIONS AND ACCURATELY REPRESENTS THE EQUIPMENT FURNISHED.
2. SENSOR ORIENTATION SHOWN FOR DETAIL ONLY. FOR ACTUAL RECOMMENDED LOCATION AND ORIENTATION REFER TO INSTALLATION INSTRUCTION MANUAL 00809-0100-4810 AND PAGES 9 AND 10 OF THIS DOCUMENT.
3. FOR MODEL SELECTIONS, REFER TO ROSEMOUNT PRODUCT DATA SHEET 00813-0100-4810.
4. 405 MAX. TEMP. 450° F DIRECT MOUNT 3-VALVE MANIFOLD, 850°F REMOTE MOUNT WITH GRAPHITE VALVE PACKING.
5. MATERIALS AVAILABLE FOR 405's ARE 316/316L STAINLESS STEEL OR HASTELLOY C-276.
6. ORIFICE IS SQUARE EDGE CONCENTRIC WITH .40 OR .65 BETA.
7. 405 RATED TO 600 ANSI/PN100 316SS.
8 REMOTE MOUNT 3-VALVE MANIFOLD WITH ADAPTER PLATE AND ½” NPT FLANGE ADAPTERS: ADAPTERS CAN BE ROTATED TO GIVE CONNECTIONS CENTERS OF 2.00 (51), 2.13 (54), OR 2.25 (57).
9 ASSEMBLY OF 405 TO FLANGE PIPE SECTION: ALIGNMENT RING WILL HAVE ETCHED FLANGE SIZE TO BE INDEXED WITH STUDS TO INSURE PROPER ALIGNMENT OF 405 TO PIPE ID.
10 STUDS, NUTS AND GASKETS NOT INCLUDED WITH 405. CORRECT STUD SIZE PER TABLE 2 IS CRITICAL FOR PROPER ALIGNMENT. RECOMMENDED GASKET: 1/16” THICK DURLON 8500 OR EQUIVALENT FOR MAX CONTINUOUS TEMPERATURE UP TO 548° F (287° C). FOR HIGHER TEMPERATURES, CONSULT FACTORY.
11. FOR OPTIMUM PERFORMANCE, ORIENTATION AND FLOW DIRECTION IS AS FOLLOWS: GAS: DIRECT MOUNT OR REMOTE MOUNT OPTIONS ARE ACCEPTABLE WITH A HORIZONTAL LINE OR DOWNWARD FLOW IN A VERTICAL LINE. REMOTE MOUNTING IS RECOMMENDED WITH UPWARD FLOW IN A VERTICAL LINE. LIQUID: DIRECT MOUNT OR REMOTE MOUNT OPTIONS ARE ACCEPTABLE WITH A HORIZONTAL LINE OR UPWARD FLOW IN A VERTICAL LINE. IT IS NOT RECOMMENDED TO USE WITH DOWNWARD FLOW IN A VERTICAL LINE. STEAM: REMOTE MOUNTING IS ACCEPTABLE WITH HORIZONTAL OR UPWARD FLOW IN A VERTICAL LINE. DIRECT MOUNTING IS RECOMMENDED ONLY IN A HORIZONTAL LINE. IT IS NOT RECOMMENDED TO USE WITH DOWNWARD FLOW IN A VERTICAL LINE.
12. SPECIAL CLEANING NOT AVAILABLE FOR HIGH TEMP. OPTION.
DIRECT MOUNT CONNECTION TYPESNOTE: 3095 TRANSMITTER SHOWN
FOR REFERENCE3051 AVAILABLE W/IDENTICAL OPTIONS
(405P SHOWN/405C AVAILABLE)
TABLE 2 (SEE NOTES 9 & 10)
FLANGE SIZE
ANSI / DN
FLANGE RATING
150# ANSI 300# ANSI 600# ANSI DIN PN16 DIN PN40 DIN PN100 JIS 10K JIS 20K JIS 40KTHREAD SIZE / (QTY.) / STUD LENGTH (NOTE:DIN & JIS ARE IN mm)
1/2" / DN15 1/2-13 (4) 4.50 1/2-13 (4) 4.75 1/2-13 (4) 5.25 M12 (4) 118 M12 (4) 130 M12 (4) 145 M12 (4) 120 M12 (4) 120 M16 (4) 1401" / DN25 1/2-13 (4) 4.50 5/8-11 (4) 5.25 5/8-11 (4) 5.75 M12 (4) 120 M12 (4) 135 M16 (4) 165 M16 (4) 130 M16 (4) 140 M16 (4) 140
1-1/2" / DN40 1/2-13 (4) 5.00 3/4-10 (4) 5.75 3/4-10 (4) 6.50 M16 (4) 120 M16 (4) 135 M20 (4) 175 M16 (4) 130 M16 (4) 150 M20 (4) 1502" / DN50 5/8-11 (4) 5.50 5/8-11 (8) 5.75 5/8-11 (8) 6.50 M16 (4) 140 M16 (4) 145 M24 (4) 180 M16 (4) 130 M16 (8) 150 M16 (8) 1503" / DN80 5/8-11 (4) 5.75 3/4-10 (8) 6.50 3/4-10 (8) 7.25 M16 (8) 150 M16 (8) 165 M24 (8) 185 M16 (8) 140 M20 (8) 170 M20 (8) 1704" / DN100 5/8-11 (8) 5.75 3/4-10 (8) 6.75 7/8-9 (8) 8.00 M16 (8) 150 M20 (8) 165 M27 (8) 200 M16 (8) 150 M20 (8) 170 M22 (8) 1805" / DN125 3/4-10 (8) 6.00 3/4-10 (8) 6.75 1-8 (8) 9.00 M16 (8) 155 M24 (8) 170 M30 (8) 230 M20 (8) 150 M22 (8) 180 M24 (8) 1906" / DN150 3/4-10 (8) 6.50 3/4-10 (8) 7.50 1-8 (12) 9.50 M20 (8) 155 M24 (8) 185 M30 (12) 240 M20 (8) 170 M22 (12) 180 M30 (12) 2108" / DN200 3/4-10 (8) 6.75 7/8-9 (12) 8.25 1-1/8-7 (12) 10.25 M12 (12) 160 M27 (12) 205 M33 (12) 265 M20 (12) 170 M22 (12) 180 M30 (12) 23010" / DN250 7/8-9 (12) 7.00 1-8 (16) 8.25 1-1/4-8 (16) 10.50 M24 (12) 170 M30 (12) 210 M36 (12) 270 M22 (12) 180 M24 (12) 200 M30 (12) 24012" / DN300 7/8-9 (12) 7.00 1-1/8-7 (16) 9.00 1-1/4-8 (20) 11.00 M24 (12) 180 M30 (16) 240 M39 (16) 280 M22 (16) 180 M24 (16) 200 M36 (16) 260
SIZE
SCALE:
DRAWING NO.
WT. SHEET OF
AFSCM.NO.
2 6
00405-1001NONE
BOULDER, COLORADO
Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary
®
3X B31.1 VALVE3X LOCKING PLATE
3X LOCKING SCREW & WASHER
2X 1/4 NPT VENT
405P OR 405C8.06 (205) BOTH CLOSED MIN.8.82 (224) BOTH OPEN MAX.
6.08 (154) CLOSED MIN.6.33 (161) OPEN MAX.
COPLANAR OR TRADITIONALMOUNT ADAPTER
2X TEFLON GASKETS
4X STUDS &NUTS
405P OR 405C
DIRECT-MOUNT CONNECTION TYPEB31.1
.70 (18.0)
DIRECT-MOUNT CONNECTION TYPECOPLANAR OR TRADITIONAL MOUNT ADAPTER
SIZE
SCALE:
DRAWING NO.
WT. SHEET OF
AFSCM.NO.
3 6
00405-1001NONE
BOULDER, COLORADO
Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary
®
1/4 INCH NPT ADAPTER(USED IN BOTH 1/4 & 1/2INCH APPLICATION)
2X 1/2 INCH NPT ADAPTER(ONLY USED FOR 1/2 INCH REMOTE CONNECTION)
4X NUT
2X TEFLON GASKET(USED IN 1/2 INCH APPLICATION)
2X TEFLON GASKET
4X STUD
405P OR405C
REMOTE MOUNT CONNECTION TYPE1/4 & 1/2 INCH
4X NUT
8
1.10 (28) .85 (22)
FLOW
SIZE
SCALE:
DRAWING NO.
WT. SHEET OF
AFSCM.NO.
4 6
00405-1001NONE
BOULDER, COLORADO
Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary
®
1/4" NPTMANIFOLD
VENTS1/4" NPTMANIFOLDVENTS
1/2" NPTPROCESSCONNECTIONS
LOW PRESSUREINSTRUMENT VALVE
HIGH PRESSUREINSTRUMENT VALVE
PIPE MOUNTING CONFIGURATION
EQUALIZERVALVE
3051S TRANSMITTER
305 3-VALVEMANIFOLD
PANEL MOUNTING CONFIGURATION
1/2" NPTPROCESSCONNECTIONS
1/4" NPT VENTCONNECTION1/4" NPT VENT
CONNECTION
LOW PRESSURE INSTRUMENTVALVE
TEST/VENTVALVE
3 VALVE / PIPE MOUNT 5 VALVE / PANEL MOUNT
HIGH PRESSUREINSTRUMENT
VALVE
TEST/VENTVALVE
EQUALIZERVALVE
305 5-VALVEMANIFOLD
3051S TRANSMITTER
REMOTE MOUNT MANIFOLD TYPES
NOTE: 3051S TRANSMITTER SHOWNFOR REFERENCE
3095 AVAILABLE W/IDENTICAL OPTIONS SIZE
SCALE:
DRAWING NO.
WT. SHEET OF
AFSCM.NO.
5 6
00405-1001NONE
BOULDER, COLORADO
Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary
top related