v3-203b-1 · vivreau russia +7 903 690 6464 vivreau new zealand tel. +64 9 377 8621 vivreau ireland...
Post on 05-Oct-2020
0 Views
Preview:
TRANSCRIPT
V3-203B-1
V3-203B-1
Dispenses chilled, still water
Substantially reduce costs of purchasing pre-bottled mineral waters
Re-usable glass bottles in 425ml, 500ml, 750ml and 1 liter sizes
Bottles can be customized
Save the environment - eliminate regular deliveries, as well as the disposal of empty bottles and packaging
High performance ice-bank refrigeration system: capable of delivering very high volumes of chilled water at low temperatures, particularly at peak demand times
Power-saving option to reduce electricity
Eliminate any storage issues
Purposedesignedbottle-washingtrays,designedtofitmostcommercialdishwashers
Removable tap nozzles for ease of cleaning and sanitizing
Stainless steel drip tray
H I G H V O U L M E B O T T L E R Re-usable glass bott ler | V3-203B-1
V3-203B-1
V3-203B-1
B
A
D D
A
DRAWN
VIVREAU www.vivreauwater.comTel 88 999 1044VIVREAU North America
V3-203B-1
27"
23"
201 2
"2
1 4"
14"14"
Technical Specifications
Compressor..........................1/2hpRefrigerant..............................R-134-aMaximum recommendedPython Length......................120"Ice Bank Size.........................20lbRecovery Time......................2.5hrElectrical Requirements.......120V/ 60Hz / 7.2AShipping Weight....................80lb (approximate)
D
E
F
C
1 2 3 4
B
A
321 5
C
D
4 6 7 8
A
B
A3
SCALE:1:10
DWG NO.
TITLE:
REVISION
DO NOT SCALE DRAWINGMATERIAL:
Date
NAME
FINISH:
Drawn
Revision
VIVREAU North AmericaTel 877 999 1044www.vivreauwater.com
This Drawing is copyright and is the property of Vivreau Limited. It may not be copied or reproduced without theexpress permission of Vivreau Limited COPYRIGHT C VIVREAU LIMITED 2009
DATE
DATEApproved
Viv 055 03.1
Chiller EVOVIVREAU North America
RJ 12.10.10
V3-203B-1
A
D D
A
DRAWN
VIVREAU
NOT TO SCALE
www.vivreauwater.comTel 88 999 1044VIVREAU North America
1). Front VentilationShowing Ventilation grilles cut in a standard door panel
2). Side VentilationVentilation grilles cut in the sideof a standard cabinet. The grilles may be fitted on either side provided they ventilate into a free and unobstructed area
Cut-out detail for the available12" VIVREAU grill, shown in a door
The cabinet may be ventilated in several different ways to prevent excessive heat build-up. the methods shown all take advantage of natural circulation by placing two grilles or cut-outs; one near the base and the other at the top of the enclosure.
Available VIVREAU Grill
4). Base CutoutVentilation can be made to the base of the cabinet, with the removal of a narrow section of floor, immediately behind the door and trim with roll edging strip. Typical cut-out size must not be less than 11.0" wide x 1.5" deep
PLEASE NOTEAll vents must open to fresh air in a free and unobstructed area.
3). Base VentilationVentilation grilles cut in the cabinet'sbase panel and base plinth. Top ventilationwill also be required in either the side panelsor a cut-out in the top of the door.
45 8
"
2"
2"
45 8
"
11"
11 34 "
51 8
"
41 2
"
38 "
B
C
D
1 2
A
321 4
B
A
5 6
FINISH:
Name Modification
MATERIAL:
ALL DIMENSIONS IN INCHES
REVISION
TITLE:
DWG NO.
SCALE:1:50 SHEET 1 OF 1A4
C
WEIGHT:
Viv066 .01
Preferred Methods of Cabinet Ventilation
DRAWN/DATE
VIVREAU North AmericaVivreau North America
Tel.877 999 1044www.vivreau.com
DO NOT SCALE DRAWING
This Drawing is COPYRIGHT C 2013 and is the sole propertyof VIVREAU Limited. It sall not be copied or reproduced in any form without the express permission of VIVREAU Limited
ORJ 27.06.2013
24 Square inches of opening is required for both the top and bottom vents
V3-203B-1
BOTTLER North Amer ica V3-203B-1 Speci f icat ion Sheet
Product Dispensed:Advancedmicro-filtered,chilledstillwater
Application:ForthepurposeoffillingVivreaure-usableglassbottles
Equipment Dimensions:See Drawings of component parts, options A and B
Cobra Tap 19 3/4” Inches (total tap height mounted) *Maximum Counter thickness for mounting cobra tap 1 ½”
Option A Minimum Space Required: Height 24” Width 30” Depth 24”
Option B Minimum Space Required: Height 29 ½” Width 24” Depth 24”
The following services are required to be supplied by the customer and must be available prior to installation:
1 potable 1/2” cold water supply terminating in a ½” ball valve, ½” female pipe thread. (Ball valve must be accessible for service and installation)
*TheVivreausystemincorporatesbackflowprevention,anyadditionalbackflowdevicesrequiredbylocalorstatecodemustalsobesuppliedbythecustomerpriortoinstallation.Thereshouldnotbeanyotherfilters/pre-filtersbeforetheVivreausystem.
Water Supply½” Threaded Ball Valve
V3-203B-1
Minimum water pressure 50 PSI
Minimumwaterflow80Gallonsperhour
1 15amp electrical receptacle (5-15) 120v/60hz
Electrical run current 7 amps
Cut out for Drip Tray and Cobra as per attached template
Drip Tray Drain. Customer needs to supply a rigid vertical pipe that drains to a properly trapped drain according to local codes. The vertical pipe for the drip train must be located inside the installation cabinet and must be at least 1 1/4” ID.
If the system is to be installed in an enclosed space or cabinet adequate ventilation must be provided. (Failure to provide ventilationwillaffectwaterquality)
Location of Services: (all services must be accessible for installation and service)
Please ensure all services are kept within 40” of bottling system
Watershut-offvalvetobelocatedatlowlevel.Pleaseensurethatthereissufficientroomfora12”longfittingtobeconnectedtotheshut-offvalve.
Top of waste receptacle should be located a minimum of 6” below the work surface the drip pan will be installed in.
*The taps must be mounted on the work surface directly above the main system.
Insulation:PleaseensurethatallwaterpipesfeedingtheVivreauSystemarecorrectlyinsulatedtoensurethatthewaterdoesnotheatupwithinthepipespriortoenteringtheVivreausystem.Thisisessentialforwaterqualityreasons.
If the system is to be installed in an enclosed space, adequate ventilation must be provided.
For Indoor Use Only
VIVREAU Benelux+31(0)881117111
VIVREAU UK (head office)+44 ( 0)845 674 9655
VIVREAU Russia+7 903 690 6464
VIVREAU New ZealandTel. +64 9 377 8621
VIVREAU Ireland+44 ( 0)845 674 9655
VIVREAU USA+1 877 999 1044
VIVREAU South Africa+27 82 292 1326
VIVREAU Switzerland+41 79 415 65 65
VIVREAU Austria+49 (0) 9401 607 216
VIVREAU Canada+1 877 999 1044
VIVREAU Australia+(61) 2 9486 4226
VIVREAU Poland+48 730 797 373
VIVREAU Spain+34 619 230 140
VIVREAU Sweden0046 70 1092918
VIVREAU Denmark+45 22 52 80 03
VIVREAU Finland00358 40 741 5100
VIVREAU France+33 632 8293 09
VIVREAU Germany+49 (0) 9401 607 216
VIVREAU Italy+39 035 19964474
VIVREAU Netherlands+31(0)881117111
VIVREAU Romania+40 722 542 507
NORTH AMERICA
EUROPE
AND BEYOND
top related