(and facilities and force mains, oh my)!

29
Pumps (and facilities and force mains, oh my)!

Upload: others

Post on 04-Oct-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Pumps(and facilities and force mains, oh my)!

Speaker Bio

Adam Rose, PE, GISP 14+ years modeling experience Sanitary Product Manager

Father of 3 Tinkerer

Series Information

Comment! We can incorporate into later webinars

Introduction Wet Weather Calibration Pumps! Validation

Review

Copy of first presentation: http://xps.link/ss1 Copy of second presentation: http://xps.link/ss2 Copy of third presentation: http://xps.link/ss3 Major Comments: Guidelines? WaPUG, Rules for Responsible Modeling http://xps.link/wapug

Validation v. Calibration

Calibration Source Usage

Actual Data 50%

Historical/Field Intuition 24%

Your Gut/Intuition 11%

Another Method 10%

Another Model 6%

Quick Overview Reality vs. Model Important Features Examples

Pumps Storage Force mains Controls

How we can model this madness

Pumps Agenda

Super Quick Review

Norweco - PosaPrime

US EPA

Don’t be confused! Spot the difference

Helpful hint: think function, not form Head, flow, speed, logic

Reality vs. Model

vs.

Pump Choices:1. Pump Location: submerged or dry2. Displacement type: positive or centrifugal (or axial)3. Motor speed: variable or fixed4. Orientation: horizontal or vertical5. Appurtenances: grinders, screens

Pumps: Reality

http://sswm.info

Configuration Station Operation Pump Operation

Examples: Reality

Configuration Station Operation Pump Operation

Examples: Reality

Actually, this time it’s a quiz!!!

Poll

Configuration Station Operation Pump Operation

Examples: Reality

flow

head

Pump Choices:1. Head Type: Dynamic or Static2. Rating Type: Node depth or wet well volume3. Motor Type: Variable or fixed speed4. Logic: Simple or remote/complex flow control

Pumps: Model

4 Basic Types

Examples: Model

Type Based On CurveTypically

Location Speed

1 Wet Well Volume Incremental Off-Line Fixed

2 Inlet Node Depth Incremental In-Line Fixed

3 Outlet - Inlet Head Continuous In-Line Fixed

4 Inlet Node Depth Continuous In-Line Variable

Logic, per time step

Notes No start/stop levels A value of 0 can be used in the curve Least popular pump option

#1 - xpswmm

WETWELL

Volume Curve Pump Flow

Logic, per time step

Notes No start/stop levels A value of 0 can be used in the curve During low flow the pump will automatically reduce flow

#2 - xpswmm

Inlet Depth Curve Pump

Flow

Logic, per time step

Notes: If u/s water elevation is above the start the pump will operate Popular pump option

#3 - xpswmm

Δ us/ds Curve Pump Flow

Nothing Horsepower Design Point 3 Point Curve Factory Testing Field Testing

Dynamic Pump Data

Better

Q*H*C/e4/3*H 0

H Q0 2Q

\_(ツ)_/

Logic, per time step

Notes: If u/s water elevation is above the start the pump will operate

#4 - xpswmm

US Water Depth Curve Pump

Flow

Variable Speed Use incremental pumps or special control item

Depth Controlled (not at lift station) Special control item

Other Pump Types

Summary

Reality ModelH-Q

Levelslocation, displacement type, orientation, appurtenances,

motor type, generator settings, PLC, power supply,

etc…

coatings, materials, thrust restraints, cranes, access

panels, start-up/ shut-down procedures,

Upstream elevation, downstream elevation, name,

description, network topology

GIS data, CAD data, SCADA data, gauge data, calibration data,

scenario, real-time control features, etc…

the head/flow/[speed] relationship

the settings for when pumps are on/off

Simplified Purpose: Cost & Operation Reality vs. Model

Wet Well Discussion

Simplified Purpose: defeat gravity ($) Reality vs. Model

Attenuation Note!

Force Main Discussion

Sr82lee.com

Simplified Purpose: make smarter choices Reality vs. Model

Some Types Simple level sensors SCADA (various types/sensors) Level Metered flow (VFD)

Logic: Pump Control

Watertreatmentprocess.net

Pump input page review

Inferred Values

Pump/model start-up

Upstream > Downstream

Gotchas!!!

1

3

2

4DEPTH

ELEVATION

Demonstrations

1. Build from scratch Ideal Ingredients: pump curves, wet well plans

2. Working Examples…

Demonstrations

Summary

FORM: Reality <> Model FUNCTION: Reality ~= Model

Need more help? Consider training!

XPSWMM :: knowledge base articles, support portal

Don’t forget: FINAL WEBINAR coming up next!

Thank you for joining this presentation,

Pumps!by

Adam Rose PE, [email protected]

Contact XP SolutionsAmericas: +1 888 554 5022 [email protected] Pacific: +61 7 3310 2302 [email protected]: +44 0 1635 582555 [email protected]

www.xpsolutions.com

Questions? Comments?