Approved Components List

Mechanical Components

For the Manufacture of The Volkswagen Group

„Technology-Specific Part“

Version date: 01. January 2020: Version 2.2

Page 2: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 1 of 41

Change history

Version Date Type of change Chapter

2.2 Jan. 01, 2020

• Editoriell updates • Update of order number, order code • Order number added • Update of order number, order code • Update of order number, order code • Order number added • Order number added • Update of order number, order code • Update of order number, order code • Update of order number, order code

Update of order number, order code • Update of order number, order code • Update of order number, order code • Update of order number, order code •

1 3.1.1.2.2 3.1.5.2.2 3.1.6.2 3.1.6.3 3.1.8 3.1.11 3.1.11.1 3.2.1.4 3.2.4.1.1 3.2.4.2.1 3.2.4.3.1 3.2.4.3.2 3.2.4.3.3

2.1 Jan. 01, 2019

• Editoriell updates • Update of order number, order code • Update of order number, order code • Order number added • Update of order number, order code • Update of order number, order code • Order number added • Order number added • Order number added • Order number added • Order number added • Order number added • Order number added • Order number added • Order number added • Order number added • Order number added

1 3.1.2.1 3.1.2.2 3.1.6.2.1.2 3.1.9 3.2.1.1.2.2 3.2.1.2.3 3.2.2.1.3.1 3.2.2.1.3.2 3.2.3.1.1.3 3.2.3.1.2.2 3.2.3.1.2.4 3.2.4.1.1 3.2.4.2.1 3.2.4.2.3 3.2.4.3.1 3.2.4.3.3

2.0 Jan. 01, 2018

• Editoriell updates • Advice added • Table updated (new series) • New components • Advide added • Table updated • Diaphragm accumulator deleted • Change of production serie (new guideline for pressure equipment) • Update of order code, order number, techn. Data • New series

1 3.1.2 3.1.5.2.1 3.1.8 3.1.9 3.1.10 3.1.11.1 3.1.11.2 3.2.2.1.1 3.3.1

Annotation:

This document added the approved components list mechanic for the manufacture of the Volkswagen group “technology specific part”. Changes in content are marked in grey.

Page 3: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 2 of 41

Table of contents

Change history ................................................................................................................................. 1

1 Contacts ............................................................................................................................ 4

2 Notes ................................................................................................................................. 5 2.1 Usage ................................................................................................................................ 5 2.2 General information .......................................................................................................... 5

3 Overview ........................................................................................................................... 6 3.1 Pump station with tank and accessories .......................................................................... 6 3.1.1 Pumps ............................................................................................................................... 6 3.1.1.1 Fixed displacement pumps (gear pumps) ........................................................................ 6 3.1.1.2 Variable displacement pumps ........................................................................................... 6 3.1.2 Tanks ................................................................................................................................ 7 3.1.2.2 Tanks 100 to 1000 l (DIN-24339, type BN, cover type A) ................................................ 7 3.1.3 Documents storage container ........................................................................................... 9 3.1.4 Breather ............................................................................................................................ 9 3.1.5 Pressure measurement and indicating devices ................................................................ 9 3.1.5.1 Mechanical instruments .................................................................................................... 9 3.1.5.2 Electronic instruments .................................................................................................... 10 3.1.6 Filters .............................................................................................................................. 11 3.1.6.1 Maintenance indicator (electronic switching element) .................................................... 11 3.1.6.2 Single filter ...................................................................................................................... 11 3.1.6.2.1 Filter in Return line .......................................................................................................... 11 3.1.6.2.2 Inline filter in main flow (without bypass ........................................................................ 11 3.1.6.2.2.1 Medium pressure: Nominal pressure 250 bar ........................................................... 11 3.1.6.3 Duplex switch filter .......................................................................................................... 12 3.1.6.3.1 Duplex switch filter für return line ................................................................................... 12 3.1.6.3.2 Duplex switch filter in main flow (without bypass) .......................................................... 13 3.1.7 Oil-water heat exchangers .............................................................................................. 13 3.1.8 Cooling water flow indicator ............................................................................................ 13 3.1.9 Thermostat ...................................................................................................................... 14 3.1.10 SYTRONIX – variable speed pump drives ..................................................................... 14 3.1.11 Cytropac – variable speed pump hydraulic units ............................................................ 16 3.1.11.1 Assembly kit for Cytropac power units............................................................................ 17 3.1.12 Accumulators .................................................................................................................. 18 3.1.12.1 Diaphragm type accumulator .......................................................................................... 18 3.1.12.2 Bladder-type accumulator ............................................................................................... 18 3.1.12.3 Accumulator shut-off block (with electrical unloading) .................................................... 18 3.1.12.4 Accumulator charging valve ............................................................................................ 18 3.1.12.5 Isolator valve with test connection .................................................................................. 18 3.2 Control devices ............................................................................................................... 19 3.2.1.1.1.1 Standard .................................................................................................................... 19 3.2.1.1.2 Size 6 – solenoid with reduced electric power consumption (DC24V - 8 Watts) ........... 21 3.2.1.1.3 Size 10 with standard solenoid (DC24V - 30 Watts) and cubic connector ..................... 23 3.2.1.1.4 Size 10 – with reduced Size electric power consumption (DC24V - 8 Watts) ................ 24 3.2.2 Isolator valves ................................................................................................................. 27 3.2.2.1 Check valves ................................................................................................................... 27 3.2.2.1.1 Inline valves .................................................................................................................... 27 3.2.2.1.3 Sandwich plate valves .................................................................................................... 27

Page 4: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 3 of 41

3.2.3 Pressure valves .............................................................................................................. 28 3.2.3.1 Pressure relief valves ..................................................................................................... 28 3.2.3.1.1 Direct operated valves .................................................................................................... 28 3.2.3.1.2 Pilot operated .................................................................................................................. 32 3.2.3.2 Pressure reducing valves ............................................................................................... 34 3.2.3.2.1 Direct operated ............................................................................................................... 34 3.2.4 Flow control valves ......................................................................................................... 37 3.2.4.1.1 Pipe fitting ....................................................................................................................... 37 3.2.4.2 Throttle check valves ...................................................................................................... 37 3.2.4.2.1 Pipe fitting ....................................................................................................................... 37 3.3 Cylinders ......................................................................................................................... 39 3.3.1 Tie rod cylinders .............................................................................................................. 39 3.4 Accessories ..................................................................................................................... 39 3.4.1 Adapter and cover plates ................................................................................................ 39 3.4.1.1 Adapter for mating connector ......................................................................................... 39 3.4.1.2 Cover plates .................................................................................................................... 39

4 Data sheets - not specified ............................................................................................. 40

5 Systems with flame-resistant hydraulic fluids of the HFC group .................................... 40

Page 5: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 4 of 41

1 Contacts

Central Bosch Rexroth Hydraulics contact: Daniel DeTroy Global Account Management Maria-Theresienstr. 3 97816 Lohr a.M. Tel. +49 (0 ) 9352 18 5334 Bosch Rexroth Hydraulics contact for Volkswagen AG and Volkswagen Sachsen GmbH:

Bosch Rexroth AG Stefan Bödecker Regionalzentrum Nord – Geschäftsbereich Hydraulik Walsroder Strasse 93 30853 Hannover-Langenhagen Tel. +49 (0) 173 315 6697 Fax +49 (0) 711-811517-3152 E-mail: [email protected]

Bosch Rexroth Hydraulics contact for AUDI AG:

Bosch Rexroth AG Hans-Jürgen Hierling Regionalzentrum Süd – Geschäftsbereich Hydraulik Parkring 4 85748 Garching bei München Tel. +49 (0 )89-12714-323 Fax +49 (0) 711-811512-5387 E-mail: [email protected]

Bosch Rexroth Hydraulics contact for Škoda Auto:

Roman Jaroš Škoda Auto Plant M4 Tezebni 2 CZ 293 60 Mladá Boleslav CZ-627 00 Brno Tel. +420 (5) 48126-375 Fax +420 (5) 48 126-112 E-mail: [email protected]

Bosch Rexroth Hydraulics contact for Volkswagen Motor Polska:

Bosch Rexroth SP.z.o.o. Slawomir Sokólski Ul Wymyslowskiego 3 55-080 Nowa Wies Wroclawska Tel. +48 (0) 71 364 - 73 22 Fax +48 (0) 71 364 - 73 24 E-mail: [email protected] 24/7-Hotline Bosch Rexroth AG +49 (0) 93 52 / 40 50 60

Page 6: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 5 of 41

2 Notes

2.1 Usage The basis for the following approved components list is the mechanical specification for the component manufacturing of the Volkswagen Group in the current edition. The respective requirements and restrictions must be observed.

2.2 General information The following table (chapters 3 and 4) lists all components that may be used when designing mineral-oil hydraulic systems (used medium: HLP-D) for the plants of the VOLKSWAGEN group specified on page 1. When using HFC fluids (reference oil "Ultrasafe 620" by Petrofer) the approved components list for foundry production of VOLKSWAGEN group must be complied with.

The use of components that are not listed in this table requires a written special authorization. A special authorization is not required if the component is not an active functional element. This includes: Steel components, assembly parts, subplates, cover plates and sandwich plates without hydraulic function, orifice inserts, individual, standard and serial control blocks, manifolds (e.g. type HSR) and stacking systems (e. g. type IH20) and card holders for amplifier cards.

The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance of this document. It was compiled in cooperation with Volkswagen AG.

Page 7: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 6 of 41

3 Overview All components with locking functions are marked with a lock "“ symbol. All components that are used have to be free of chromium VI. Carry out all labels in the planning language and in the language at the plant´s location.

3.1 Pump station with tank and accessories 3.1.1 Pumps 3.1.1.1 Fixed displacement pumps (gear pumps)

Designation (type) Techn. data Order number (manufacturer) Data sheet

PGF2-2X/006RE20VE4 PGF2-2X/006RE20VE4-A468

210bar; 9.4l/min with n=1450 both types are structurally identical R900 245 715

R901 214 655

10 213

PGF2-2X/008RE20VE4 PGF2-2X/008RE20VE4-A468

210bar; 11,6l/min with n=1450 both types are structurally identical R900 984 157

R901 214 657 PGF2-2X/011RE20VE4 PGF2-2X/011RE20VE4-A468

210bar; 16l/min with n=1450 both types are structurally identical R900 949 135

R901 214 658 PGF2-2X/013RE20VE4 PGF2-2X/013RE20VE4-A468

210bar; 19,3l/min with n=1450 both types are structurally identical R900 943 181

R901 207 424 PGF2-2X/016RE20VE4 PGF2-2X/016RE20VE4-A468

210bar; 23,2l/min with n=1450 both types are structurally identical R900 932 193

R901 214 660 PGF3-3X/019RE20VE4 PGF3-3X/019RE20VE4-A468

210bar; 27,4l/min with n=1450 both types are structurally identical R900 943 182

R901 214 664 PGF3-3X/022RE20VE4 PGF3-3X/022RE20VE4-A468

210bar; 31,9/min with n=1450 both types are structurally identical R900 932 126

R901 214 667 PGF3-3X/025RE07VE4 210 bar; 36.8 l/min with n=1450 R900 932 088 PGF3-3X/032RE07VE4 210 bar; 47.1 l/min with n=1450 R900 932 112 PGF3-3X/040RE07VE4 210 bar; 58.7 l/min with n=1450 R900 932 111 PGH5-3X/063RE11VE4 250 bar; 92.8 l/min with n=1450 R901 147 122

10 227 PGH5-3X/080RE11VE4 250 bar; 116.9 l/min with n=1450 R901 147 123 PGH5-3X/100RE11VE4 250 bar; 143.8 l/min with n=1450 R901 147 124

3.1.1.2 Variable displacement pumps 3.1.1.2.1 Vane pumps

Designation (type) Techn. data Order number (manufacturer) Data sheet

PV7-1X/10-14RE01MC3-16 160 bar; 21 l/min with n=1450 R900 598 753

10 515

PV7-1X/16-20RE01MC3-16 160 bar; 29 l/min with n=1450 R900 592 237 PV7-1X/25-30RE01MC3-16 160 bar; 43.5 l/min with n=1450; R900 586 235 PV7-1X/40-45RE37MC3-16 160 bar; 66 l/min with n=1450 R900 590 087 PV7-1X/63-71RE07MC3-16 160 bar; 108 l/min with n=1450 R900 511 986 PV7-1X/100-118RE07MC3-16 160 bar; 171 l/min with n=1450 R900 511 215

3.1.1.2.2 Axial piston pumps

Designation (type) Techn. data Order number (manufacturer) Data sheet

A10VSO18DFR1/31R-PPA12N00SO155 280 bar; 27 l/min with n=1450 R910 966 386

92 711

A10VSO28DFR1/31R-PPA12N00SO155 280 bar; 42 l/min with n=1450 R910 969 498 A10VSO45DFR1/31R-PPA12N00SO155 280 bar; 68 l/min with n=1450 R910 921 747 AA10VSO71DFR1/31R-VPA42N00SO155 280bar; 107l/min bei n=1450 R902 521 494 A10VSO28DFLR/31R-PPA12N00 Power controller specification required XXXX XXX XXX A10VSO45DFLR/31R-PPA12N00 Power controller specification required XXXX XXX XXX A10VSO71DFLR/31R-PPA12N00 Power controller specification required XXXX XXX XXX A10VSO100DFLR/31R-PPA12N00 Power controller specification required XXXX XXX XXX A10VSO140DFLR/31R-PPA12N00 Power controller specification required XXXX XXX XXX

Page 8: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 7 of 41

3.1.2 Tanks

The system must be protected in accordance with DIN 4413 with suitable means against excessive pressures (this should preferably take place near the pressure supply unit). Moreover, it is to ensure by appropriate visualization of the pressure existing within the system that an outgoing from the complex risks are excluded.

3.1.2.1 Tanks 40 and 60 l Electric motors up to 5.5 kW must be connected via plug (connector on the terminal box)

Denomination Designation (type) Order number (manufacturer)

40 Liter 60 Liter numbers

Tank ABZBR- 40/09-B 1 A/M R901 028 367 1

Tank ABZBR- 60/09-B 1 A/M R901 029 093 1

Oil level indicator AB31-21/127T R900 013 663 1 1

Air breather PI0125 SM-L/UM-OS R901 064 797 1 1

Level sensor LK7022 L=264 R900 245 162 1 1

Thermostat TR7439+TT3050+E35030 R901 479 122 1 1

Ball valve AB21-34/G ½-64 R900 025 994 1 1

Plug VERSCHLUSSSCHRAUBE ZN10001-G1/2A-F-ST R913 011 611 1 1 3.1.2.2 Tanks 100 to 1000 l (DIN-24339, type BN, cover type A)

Nominal tank volume [liters] 100 160 250 400 630 800 1000

R90

1 16

2 67

8

R90

1 16

2 67

9

R90

1 16

2 68

0

R90

1 16

2 68

1

R90

1 16

2 68

2

R90

1 16

2 68

3

R90

1 16

2 68

4

Order no. Denomination 1 1 1 2 R900 543 908 Closure AB40-19/324A-AL/M-6 1 1 1 2 R900 320 727 Closure AB40-19/449A-AL/M 2 2 2 R900 007 824 Oil level indicator AB31-21/127 1 1 1 1 1 1 2 R913 011 605 Pug screw ZN10001-G1A-N-ST 1 1 1 1 1 1 1 R901 261 671 Ball valve S.288.N-36/DN25/PN400 1 1 1 1 1 1 1 R900 762 370 Level sensor LK7022 + E43001 1 1 1 1 1 1 1 R900 026 428 Label AB31-21/MIN 1 1 1 1 1 1 1 R900 026 429 Label AB31-21/MAX 1 1 1 1 1 1 1 R901 479 122 Thermometer TR7439 + TT3050 + E35030 1 1 1 1 1 1 1 R900 241 093 Label AB30-11/yellow-100 ltr.+ oil grade + VW no. 1 R900 241 092 Label AB30-11/yellow-160 ltr. + oil grade + VW no. 1 R900 241 091 Label AB30-11/yellow-250 ltr. + oil grade + VW no. 1 R900 241 090 Label AB30-11/yellow-400 ltr. + oil grade + VW no. 1 R900 241 088 Label AB30-11/yellow-630 ltr. + oil grade + VW no. 1 R900 241 087 Label AB30-11/yellow-800 ltr. + oil grade + VW no. 1 R900 241 076 Label AB30-11/yellow-1000 ltr. + oil grade + VW no. 1

alternate to the temperature sensor R901278209 the temperature sensor (includes the plug) can be used

Material number for accessory set (without tank) according to the following table

Page 9: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 8 of 41

Order no.. Designation (type) quantity R913 010 917 Temperatursensor TT3050+TR7439 1 1 1 1 1 1 1

3.1.2.3 Filling: - Filling couplings have to be used in any case. - If an inline filter is installed in the return flow, the filling nipple is to be modified so as to ensure filling via the

filter. Designation (type) Techn. data

Order number (manufacturer) Data sheet

Coupling plug MD-012-2-WR033-19-1 R900 068 245 Make Walther Dust protection cap MD-012-5-74 KU R900 030 420

Orifice (for Tank 40 and 60 Liter) 3,0 / 17,9 x 1,5 ST R900 739 428 For the Salzgitter plant, a filling circuit with additional filling level sensor is required for tanks with nominal volume of 100 – 1000 Liter:

Base plate G3/4 G534/01 R900 467 259 48 054

Sandwich plate HSZ10A079-3X/M00 R900 537 265 48 052

Adapter plate HSE10B06A001-31/M00 R900 303 948 48 045

Directional valve

4WE6D6X/EG24N9K4 oder 4WE6D6X/EG24N9K72L SO407

R900 561 274 R901 235 380

23 178

23 178-00

Designation (type) Techn. data Order number (manufacturer) Data sheet

Filling level sensor (requested additional) LK1222 R901 120 129 Make: ifm Filling level sensor (replaces LK7022) LK8122 R901 076 785 Make: ifm

3.1.2.4 Pump start-up and pump safety block With standard solenoid (DC24V - 30 Watts) and cubic connector

plug-in connector design A according to EN175301-803 with LED;

Solenoid with reduced electric power consumption (DC24V - 8 Watts) in version “SO803” NOTE: Place notice on mounting plate. circular plug-in connector M12x1 according to IEC 61076-2-101 m. LED

Page 10: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 9 of 41

Designation (type) Techn. data Order number (manufacturer) Data sheet

DBAW15BF2-2X/100U6EG24N9K4 Pump safety block Upon request

25 891

DBAW30BH2-2X/100Z6EG24N9K4 Pump safety block R900 978 920 DBAW15BF3-2X/100U6EG24N9K4 Pump safety block R900 964 599 DBAW25BH2-2X/200-6EG24N9K4 Pump safety block R900 969 376 DBAW30BH2-2X/200-6EG24N9K4 Pump safety block R900 955 670 DBAW30BH3-2X/200-6EG24N9K4 Pump safety block R900 954 831 DBAW30BH2-2X/315-6EG24N9K4 Pump safety block; R900 957 485 DBAW30BH3-2X/315-6EG24N9K4 Pump safety block; R901 194 365 DBAW40BF2N1X/100P085US6EG24N9K4 SO618 Pump safety block; R900 977 320

3.1.3 Documents storage container

Designation (type) Techn. data Order number (manufacturer) Data sheet

Document box 3331-3045-20 Suitable for a file size DIN A4 with star knob R901 375 173 ---

3.1.4 Breather - with clogging indicator - filling protection

Designation (type) Techn. data Order number (manufacturer) Data sheet

Air breather filter PI0125 SM-L/UM-OS Mounting 6 x M5, hole circle Ø 73 mm R901 064 797 see Mahle

3.1.5 Pressure measurement and indicating devices 3.1.5.1 Mechanical instruments

Designation (type) Techn. data Order number (manufacturer) Data sheet

MS4A2X/ Indication up to 315 bar, 6 connections R900 421 643

50 034 MSL2A2X/180 Indication up to 180 bar; 6 connections; leak-free R900 386 956

MSL2A2X/315 Indication up to 315 bar; 6 connections; leak-free R900 393 896

ABZMM 63-600BAR/MPA-R/B330G Pressure gauge with red mark R901 210 122

50 205 ABZMM 63-100BAR/MPA-U/V-G Pressure gauge R900 051 035 ABZMM 63-160BAR/MPA-U/V-G Pressure gauge R900 077 650 ABZMM 63-250BAR/MPA-U/V-G Pressure gauge R900 771 208 AB42-15/10-100AM1 Pressure control unit with pressure gauge R901 064 994 AB42-15 AB42-15/10-200AM1 Pressure control unit with pressure gauge R901 064 995 AB42-15

Page 11: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 10 of 41

3.1.5.2 Electronic instruments

3.1.5.2.1 Pressure switch (Selection analogous to IFM)

Designation (type) Techn. data

Order number (manufacturer) Data sheet

HEDE10-3X/100/1/-GI-K35-0 up to 100 bar; 18 bis 30 VDC; M12x1, digit. display., Output: 1 switching, 1 analog R901 425 473

30 277

HEDE10-3X/250/1/-GI-K35-0 up to 250 bar; 18 bis 30 VDC; M12x1, digit. display., Output: 1 switching, 1 analog R901 425 474

HEDE10-3X/400/1/-GI-K35-0 up to 400 bar; 18 bis 30 VDC; M12x1, digit. display., Output: 1 switching, 1 analog R901425 475

HEDE10-3X/100/2/-GI-K35-0 up to 100 bar; 18 bis 30 VDC; M12x1, digit. display., Output: 2 switching R901 425 452

HEDE10-3X/250/2/-GI-K35-0 up to 250 bar; 18 bis 30 VDC; M12x1, digit. display., Output: 2 switching R901 425 453

HEDE10-3X/400/2/-GI-K35-0 up to 400 bar; 18 bis 30 VDC; M12x1, digit. display., Output: 2 switching R901 425 454

3.1.5.1.2 Pressure transducer (for SYTRONIX-Kit)

Designation (type) Techn. data

Order number (manufacturer) Data sheet

HM 20-2X/100-C-K35 Up to100 bar R901 342 024 30272 HM 20-2X/250-C-K35 Up to 250 bar R901 342 026 Leitungsdose 4P M12 ABGEWINKELT 5M Cable with connector M12x1, 90° R900 779 503 08006

Page 12: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 11 of 41

3.1.6 Filters

The installation of duplex switch filters may be required (according to plant-specific specifications) (only use switching point "100 %" for maintenance indicator). Refer to: Chapter 3.1.5.3

3.1.6.1 Maintenance indicator (electronic switching element)

Designation (type) Techn. data Order number (manufacturer) Data sheet

WE-2SP-M12x1 M12x1, 75 %, 100 % R928 028 410 RD 51 450

3.1.6.2 Single filter 3.1.6.2.1 Filter in Return line

3.1.6.2.1.1 Inline filter in return flow or bypass circuit: Nominal pressure 50 bar (with bypass)

Designation (type) Techn. data Order number (manufacturer) Data sheet

110LEN0100-PWR10A00-V2,2-M-R3 bis 36l/min, Reinheitsklasse 17/15/11 R928 058 063

51 447

110LEN0160-PWR10A00-V2,2-M-R6 bis 100l/min, Reinheitsklasse 17/15/11 R928 050 463 110LEN0250-PWR10A00-V2,2-M-R6 bis 150l/min, Reinheitsklasse 17/15/11 R928 050 558 110LEN0400-PWR10A00-V2,2-M-R6 bis 175l/min, Reinheitsklasse 17/15/11 R928 050 654 110LEN0100-PWR3A00-V2,2-M-R3 bis 22l/min, Reinheitsklasse 14/12/09 R928 058 064 110LEN0160-PWR3A00-V2,2-M-R6 bis 48l/min, Reinheitsklasse 14/12/09 R928 050 492 110LEN0250-PWR3A00-V5,0-M-R6 bis 95l/min, Reinheitsklasse 14/12/09 R928 046 912 110LEN0400-PWR3A00-V5,0-M-R6 bis125l/min, Reinheitsklasse 14/12/09 R928 046 913

3.1.6.2.1.2 Tank mounted return line filter: Nominal pressure 10 bar (with bypass)

Designation (type) Techn. data Order number (manufacturer) Data sheet

10TEN0100-PWR10A00-V2,2-M-R4 up to 70l/min, cleanliness class 17/15/11 R928 019 846

51 424

10TEN0160-PWR10A00-V2,2-M-R5 up to 135l/min, cleanliness class 17/15/11 R928 047 167 10TEN0250-PWR10A00-V2,2-M-R6 up to 200l/min, cleanliness class 17/15/11 R928 019 850 10TEN0400-PWR10A00-V2,2-M-S8 up to 250l/min, cleanliness class 17/15/11 R928 019 851 10TEN0100-PWR3A00-V2,2-M-R4 up to 30l/min, cleanliness class 14/12/09 R928 019 857 10TEN0160-PWR3A00-V2,2-M-R5 up to 135l/min, cleanliness class 14/12/09 R928 041 298 10TEN0250-PWR3A00-V2,2-M-R6 up to 200l/min, cleanliness class 14/12/09 R928 019 861 10TEN0400-PWR3A00-V2,2-M-S8 up to is 250l/min, cleanliness class 14/12/09 R928 019 862

3.1.6.2.2 Inline filter in main flow (without bypass 3.1.6.2.2.1 Medium pressure: Nominal pressure 250 bar

Designation (type) Techn. data Order number (manufacturer) Data sheet

245LEN0100-PWR10B00-V5,0-M-R4 up to 83 l/min, cleanliness class 17/15/11 R928 030 546

51 421

245LEN0160-PWR10B00-V5,0-M-R6 up to 165 l/min, cleanliness class 17/15/11 R928 030 549 245LEN0250-PWR10B00-V5,0-M-R6 up to 210 l/min, cleanliness class 17/15/11 R928 030 550 245LEN0400-PWR10B00-V5,0-M-R6 up to 230 l/min, cleanliness class 17/15/11 R928 030 551 245LEN0100-PWR3B00-V5,0-M-R4 up to 40 l/min, cleanliness class 14/12/09 R928 030 034 245LEN0160-PWR3B00-V5,0-M-R6 up to 92 l/min, cleanliness class 14/12/09 R928 030 037 245LEN0250-PWR3B00-V5,0-M-R6 up to 142 l/min, cleanliness class 14/12/09 R928 030 038 245LEN0400-PWR3B00-V5,0-M-R6 up to 165 l/min, cleanliness class 14/12/09 R928 030 039

Page 13: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 12 of 41

3.1.6.2.2.2 High pressure: Nominal pressure 350 bar

Designation (type) Techn. data Order number (manufacturer) Data sheet

350LEN0100-PWR10B00-V5,0-M-R4 up to 78 l/min, cleanliness class 17/15/11 R928 033 546

51 422

350LEN0160-PWR10B00-V5,0-M-R6 up to 155 l/min, cleanliness class 17/15/11 R928 033 549 350LEN0250-PWR10B00-V5,0-M-R6 up to 250 l/min, cleanliness class 17/15/11 R928 033 550 350LEN0400-PWR10B00-V5,0-M-R6 up to 350 l/min, cleanliness class 17/15/11 R928 033 551 350LEN0100-PWR3B00-V5,0-M-R4 up to 43 l/min, cleanliness class 14/12/09 R928 033 034 350LEN0160-PWR3B00-V5,0-M-R6 up to 90 l/min, cleanliness class 14/12/09 R928 033 037 350LEN0250-PWR3B00-V5,0-M-R6 up to 160 l/min, cleanliness class 14/12/09 R928 033 038 350LEN0400-PWR3B00-V5,0-M-R6 up to 230 l/min, cleanliness class 14/12/09 R928 033 039

3.1.6.3 Duplex switch filter 3.1.6.3.1 Duplex switch filter für return line

3.1.6.3.1.1 Duplex switch filter in return flow or bypass – nominal pressure 50 bar (with bypass)

Designation (type) Techn. data Order number (manufacturer) Data sheet

50LDN0100-PWR10A00-V2,2-M-R4 up to 29 l/min, cleanliness class 17/15/11 R928 039 374

51 453

50LDN0160-PWR10A00-V2,2-M-R6 up to 81 l/min, cleanliness class 17/15/11 R928 039 358 50LDN0250-PWR10A00-V2,2-M-R6 up to 102 l/min, cleanliness class 17/15/11 R928 039 360 50LDN0400-PWR10A00-V2,2-M-R6 up to 122 l/min, cleanliness class 17/15/11 R928 039 362 50LDN0100-PWR3A00-V2,2-M-R4 up to 15 l/min, cleanliness class 14/12/09 R928 039 375 50LDN0160-PWR3A00-V2,2-M-R6 up to 38 l/min, cleanliness class 14/12/09 R928 039 359 50LDN0250-PWR3A00-V2,2-M-R6 up to 56 l/min, cleanliness class 14/12/09 R928 039 361 50LDN0400-PWR3A00-V2,2-M-R6 up to 78 l/min, cleanliness class 14/12/09 R928 039 363

3.1.6.3.1.2 Tank mounted duplex switch filter in return flow – nominal pressure 10 bar (with bypass)

Designation (type) Techn. data Order number (manufacturer) Data sheet

10TDN0100-1X/PWR10A00-P2,2-M-R4 bis 70l/min, Reinheitsklasse 17/15/11 R928 048 602

51 454

10TDN0160-1X/PWR10A00-P2,2-M-R6 bis 135l/min, Reinheitsklasse 17/15/11 R928 051 508 10TDN0250-1X/PWR10A00-P2,2-M-R6 bis 200l/min, Reinheitsklasse 17/15/11 R928 048 604 10TDN0400-1X/PWR10A00-P2,2-M-S9-MP bis 250l/min, Reinheitsklasse 17/15/11 R928 048 991 10TDN0100-1X/PWR3A00-P2,2-M-R4 bis 30l/min, Reinheitsklasse 14/12/09 R928 051 466 10TDN0160-1X/PWR3A00-P2,2-M-R6 bis 135l/min, Reinheitsklasse 14/12/09 R928 051 467 10TDN0250-1X/PWR3A00-P2,2-M-R6 bis 200l/min, Reinheitsklasse 14/12/09 R928 051 468 10TDN0400-1X/PWR3A00-P2,2-M-S9-MP bis 250l/min, Reinheitsklasse 14/12/09 R928 051 469

Page 14: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 13 of 41

3.1.6.3.2 Duplex switch filter in main flow (without bypass)

3.1.6.3.2.1 Nominal pressure 50 bar

Designation (type) Techn. data Order number (manufacturer) Data sheet

50LDN0100-PWR10B00-V2,2-M-R4 up to 29 l/min, cleanliness class 17/15/11 R928 051 425

51 453

50LDN0160-PWR10B00-V2,2-M-R6 up to 81 l/min, cleanliness class 17/15/11 R928 049 976 50LDN0250-PWR10B00-V2,2-M-R6 up to 102 l/min, cleanliness class 17/15/11 R928 049 978 50LDN0400-PWR10B00-V2,2-M-R6 up to 122 l/min, cleanliness class 17/15/11 R928 049 981 50LDN0100-PWR3B00-V2,2-M-R4 up to 15 l/min, cleanliness class 14/12/09 R928 051 427 50LDN0160-PWR3B00-V2,2-M-R6 up to 38 l/min, cleanliness class 14/12/09 R928 051 428 50LDN0250-PWR3B00-V2,2-M-R6 up to 56 l/min, cleanliness class 14/12/09 R928 051 429 50LDN0400-PWR3B00-V2,2-M-R6 up to 78 l/min, cleanliness class 14/12/09 R928 051 431

3.1.6.3.2.2 Nominal pressure 160 bar

Designation (type) Techn. data Order number (manufacturer) Data sheet

150LDN0100-PWR10B00-V5,0-M-R4 up to 42 l/min, cleanliness class 17/15/11 R928 048 673

51 446

150LDN0160-PWR10B00-V5,0-M-R6 up to 118 l/min, cleanliness class 17/15/11 R928 041 756 150LDN0250-PWR10B00-V5,0-M-R6 up to 148 l/min, cleanliness class 17/15/11 R928 044 799 150LDN0400-PWR10B00-V5,0-M-R6 up to 172 l/min, cleanliness class 14/12/09 R928 046 724 150LDN0100-PWR3B00-V5,0-M-R4 up to 23 l/min, cleanliness class 14/12/09 R928 051 432 150LDN0160-PWR3B00-V5,0-M-R6 up to 58 l/min, cleanliness class 14/12/09 R928 051 433

150LDN0250-PWR3B00-V5,0-M-R6 up to 84 l/min, cleanliness class 14/12/09 R928 051 345 150LDN0400-PWR3B00-V5,0-M-R6 up to 115 l/min, cleanliness class 14/12/09 R928 046 729

3.1.6.3.2.3 Nominal pressure 400 bar

Designation (type) Techn. data Order number (manufacturer) Data sheet

400LDN0100-PWR10B00-V5,0-M-R2 up to 38 l/min, cleanliness class 17/15/11 R928 038 550

51 429

400LDN0160-PWR10-V5,0-M-S6 up to 157 l/min, cleanliness class 17/15/11 R928 039 283 400LDN0250-PWR10B00-V5,0-M-S6 up to 195 l/min, cleanliness class 17/15/11 R928 039 284 400LDN0400-PWR10B00-V5,0-M-S6 up to 230 l/min, cleanliness class 17/15/11 R928 038 551 400LDN0100-PWR3B00-V5,0-M-R2 up to 25 l/min, cleanliness class 14/12/09 R928 039 413 400LDN0160-PWR3B00-V5,0-M-S6 up to 80 l/min, cleanliness class 14/12/09 R928 039 417 400LDN0250-PWR3B00-V5,0-M-S6 up to 110 l/min, cleanliness class 14/12/09 R928 039 418 400LDN0400-PWR3B00-V5,0-M-S6 up to 150 l/min, cleanliness class 14/12/09 R928 039 419

3.1.7 Oil-water heat exchangers

Designation (type) Techn. data Order number (manufacturer) Data sheet

Heat exchanger TPL00-K-006-22/IG/VE 4 kW (18 l/min); up to 10 bar R900 028 816 AB 32-12

3.1.8 Cooling water flow indicator

Designation (type) Techn. data Order number (manufacturer) Data sheet

SBG234 1 - 50 L/min; G1/2 R996 031 607 Fa. IFM SBG246 2 - 100 L/min; G3/4 R901 176 695

SBG257 4 - 200 L/min; G1 1/4 R987 448 107

Page 15: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 14 of 41

3.1.9 Thermostat Attention: Already included in assembly kit for reservoirs according to chapt. 4.1.2.1!

Designation (type) Techn. data Order number (manufacturer) Data sheet

Thermometer TR7439 + TT3050 + E35030 2 x normally open/normally closed contacts, programmable R901 479 122 by IFM

3.1.10 SYTRONIX – variable speed pump drives

Designation (type) Techn. data Order. No. Data sh.

SYT-FCP5020-PGF023-S-FC2FS067- EF165-0001 Qpeff = 14 l/min; peff = 67 bar

Qm

ax =

23

l/min

R911 374 954

R99

9000

331

SYT-FCP5020-PGF023-S-FC2FS098- EF161-0001 Qpeff = 14 l/min; peff = 98 bar R911 374 955

SYT-FCP5020-PGF023-S-FC2FS135- EF159-0001 Qpeff = 14 l/min; peff = 135 bar R911 374 956

SYT-FCP5020-PGF029-S-FC2FS053- EF165-0001 Qpeff = 19 l/min; peff = 53 bar

Qm

ax =

29

l/min

R911 374 957

SYT-FCP5020-PGF029-S-FC2FS078- EF161-0001 Qpeff = 19 l/min; peff = 78 bar R911 374 958

SYT-FCP5020-PGF029-S-FC2FS107- EF159-0001 Qpeff = 19 l/min; peff = 107 bar R911 374 959

SYT-FCP5020-PGF029-S-FC2FS139- EF161-0001 Qpeff = 19 l/min; peff = 139 bar R911 374 960

SYT-FCP5020-PGF039-S-FC2FS058- EF161-0001 Qpeff = 26 l/min; peff = 58 bar

Qm

ax =

39

l/min

R911 374 961

SYT-FCP5020-PGF039-S-FC2FS080- EF159-0001 Qpeff = 26 l/min; peff = 80 bar R911 374 962

SYT-FCP5020-PGF039-S-FC2FS104- EF161-0001 Qpeff = 26 l/min; peff = 104 bar R911 374 963

SYT-FCP5020-PGF039-S-FC2FS144- EF153-0001 Qpeff = 26 l/min; peff = 144 bar R911 374 964

SYT-FCP5020-PGF047-S-FC2FS066- EF159-0001 Qpeff = 31 l/min; peff = 66 bar

Qm

ax =

47

l/min

R911 374 965

SYT-FCP5020-PGF047-S-FC2FS086- EF161-0001 Qpeff = 31 l/min; peff = 86 bar R911 374 966

SYT-FCP5020-PGF047-S-FC2FS119- EF153-0001 Qpeff = 31 l/min; peff = 119 bar R911 374 967

SYT-FCP5020-PGF057-S-FC2FS055- EF159-0001 Qpeff = 38 l/min; peff = 55 bar

Qm

ax =

57

l/min

R911 374 968

SYT-FCP5020-PGF057-S-FC2FS071- EF161-0001 Qpeff = 38 l/min; peff = 71 bar R911 374 969

SYT-FCP5020-PGF057-S-FC2FS099- EF153-0001 Qpeff = 38 l/min; peff = 99 bar R911 374 970

SYT-FCP5020-PGF057-S-FC2FS135- EF162-0001 Qpeff = 38 l/min; peff = 135 bar R911 374 971

SYT-FCP5020-PGF066-S-FC2FS052- EF161-0001 Qpeff = 53 l/min; peff = 52 bar

Qm

ax =

66

l/min

R911 374 972

SYT-FCP5020-PGF066-S-FC2FS072- EF153-0001 Qpeff = 53 l/min; peff = 72 bar R911 374 973

SYT-FCP5020-PGF066-S-FC2FS098- EF162-0001 Qpeff = 53 l/min; peff = 98 bar R911 374 974

SYT-FCP5020-PGF066-S-FC2FS144- EF154-0001 Qpeff = 53 l/min; peff = 144 bar R911 374 975

SYT-FCP5020-PGF068-S-FC2FS061- EF161-0001 Qpeff = 46 l/min; peff = 61 bar

Qm

ax =

68

l/min

R911 374 976

SYT-FCP5020-PGF068-S-FC2FS084- EF153-0001 Qpeff = 46 l/min; peff = 84 bar R911 374 977

SYT-FCP5020-PGF068-S-FC2FS114- EF162-0001 Qpeff = 46 l/min; peff = 114 bar R911 374 978

Page 16: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 15 of 41

All single components of the kit have to be listed in the bill of material for

• Motor-Pump-Groupe, consisting of: - E-Motor - Hydraulic pump - Bell housing - Coupling

• Frequency Converter (see approved components list Electric Version 0.14, published 02.01.2020, chapter. 3.14)

• Pressure transducer (see chapter. 3.1.5.2.2 of this document) Forced cooled motors have to be approved by planning department of end user!

Page 17: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 16 of 41

3.1.11 Cytropac – variable speed pump hydraulic units

Designation (type) Techn.data

Power (kW)

Pump

(ccm/U)

Order number

Data sheet

CYTROPAC-1X/20/ST1AS04/2/P/WD/1/7035

Up to 16 l/min, Up to 70 bar

1,5 4,0 R901 501 012

51 0

55

CYTROPAC-1X/20/ST2AS04/2/P/WD/1/7035

Up to 16 l/min, Up to 140 bar

2,2 4,0 R901 501 072

CYTROPAC-1X/20/ST2AS05/2/P/WD/1/7035

Up to 22 l/min, Up to 100 bar

2,2 5,5 R901 501 084

CYTROPAC-1X/20/ST2AS08/2/P/WD/1/7035

Up to 32 l/min, Up to 70 bar

2,2 8,0 R901 501 096

CYTROPAC-1X/20/ST4AS05/2/P/WD/1/7035

Up to 22 l/min, Up to 180 bar

4,0 5,5 R901 501 204

CYTROPAC-1X/20/ST4AS08/2/P/WD/1/7035

Up to 32 l/min, Up to 110 bar

4,0 8,0 R901 501 216

CYTROPAC-1X/20/ST4AS11/2/P/WD/1/7035

Up to 35 l/min, Up to 90 bar

4,0 11,0 R901 501 228

Sensor technology: Premium Safety: STO (deselect function possible by using electric STO-connector from assembly kit chapter 3.1.11.1) Cooler 2,0 kW (cooling water required) Attention: Pressure protection must be installed by the customer A filling coupling is always be used. The filling nipple ist to be mounted so as to be ensure filling via a return filter.

If not included in the OEM system concept, all necessary accessoires are listed in assembly kit R901522 589 descibed next page. EPLAN P8-Makro is availiabe on demand

Page 18: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 17 of 41

3.1.11.1 Assembly kit for Cytropac power units

ZUBEHOERSATZ CYTROPAC-AAD R901 522 589 for direct mounting on the hydraulic unit

(includes all subsequent positions 1.0 to 6.0)

Description Designation Order number Comment Pos.

Assembly kit pressure valve complete

DRUCKBEGR:EINHEIT 200 BAR/2900PSI-CYT&

R901 519 129 Includes Pos. 1.1 to 1.10

1.0

Pressure valve DBDS 6G1X/200 R900 423 719 1.1 Assembly kit for pressure valve

MONTAGESATZ DRUCKBEGRENZUNG DBDS

R901 506 469 Includes Pos. 1.3 bis 1.10

1.2

Reducing connector REDUZIERSTUTZEN GP-SDS-G1E-IG3/8-FKM

R901 457 138 1.3

Swivel connector SCWENKVERSCHRAUBG 24RSVW-E-S-12L-G3/8

R900 766 631 1.4

Stud end connector EINSCHRAUBVERRSCHRA 24SWOSDS-E-S-12L-G1/&

R901 389 454 1.5

Micro hose coupling MESSKUPPLUNG MCS20-SDS-E-G1/4-ST3

R900 009 090 1.6

Stud end connector EINSCHRAUBVERSCHRA 24SDS-E-S-12S-G1/4-S

R901 331 136 1.7

Hose SCHLAUCHLEITUNG 2SC10/P00-12P00-16/&

R901 516 358 1.8

Adjustible screw EINSTELLVERSCHRBG 24SWORT-Z-S-16S-ST3F&

R900 766 416 1.9

Stud end connector EINSCHRAUBVERSCHRA 24SDS-E-S-16S-G1/2-S&

R900 762 684 1.10

Assembly kit filling FUELLVORRICHTUNG MD012-2*OPT.CYTROPAC

R901 460 916 Includes Pos. 2.1 bis 2.5

2.0

Coupling plug MD-012-2-WR521-19-1 R900 214 547 2.1 Dust protection cap MD-012-5-74-KU R900 030 420 2.2

Orifice BLENDE 3,0/17,9 x 1,5-S& R900 739 428 2.3 Fitting VERBINDUNGSSTUTZEN 24T-Z-S-

18L-ST3ZOOZ R900 764 632 2.4

Stud end connector EINSCRAUBVERSCHR.24W0DS-E-S-18L-G1&

R900 012 446 2.5

Fastening kit Cytropac BEFESTIGUNGSSATZ BASE285 *OPT.CYTROPAC

R901 460 890 3.0

Kühlwasser-Thermostatventil

WASSERVENTIL FJVA 15 G1/2 R901 389 585 4.0

Electric plug-in-connector

LEITUNGSDOSE 0DEG *OPT.CYTROPAC

R901 460 889 Ausf. gerade, ohne Kabel

5.0

Electric STO-connector KONTAKTBRUECKE CYTOPAC-STO-DEAKTIV

R901 525 292 6.0

Page 19: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 18 of 41

3.1.12 Accumulators 3.1.12.1 Diaphragm type accumulator

Not approved for working hydraulics systems

3.1.12.2 Bladder-type accumulator

Accumulators of the type "HAB...-350-6X/..." are not permitted!

Designation (type) Techn. data Order number (manufacturer) Data sheet

HAB1-330-6X/0G05G-2N111-BA 1 liters R901 191 370

50 171

HAB2,5-330-6X/0G07G-2N111-CE 2,5 liters R901 191 371 HAB4-330-6X/0G07G-2N111-CE 4 liters R901 191 372 HAB10-330-6X/0G09G-2N111-CE- 10 liters R901 435 304 HAB20-330-6X/0G09G-2N111-CE- 20 liters R901 435 305 HAB32-330-6X/0G09G-2N111-CE- 32 liters R901 435 307

3.1.12.3 Accumulator shut-off block (with electrical unloading)

Designation (type) Techn. data Order number (manufacturer) Data sheet

ABZSS10E-3X/330E/S10G24K4V Pressure relief valve sealed at 330 bar R900 709 606

50 131 ABZSS10E-3X/330E/S12G24K4V Pressure relief valve sealed at 330 bar R900 709 607 ABZSS20E-3X/330E/S13G24K4V Pressure relief valve sealed at 330 bar R900 709 636 ABZSS30E-3X/330E/S309G24K4V Pressure relief valve sealed at 330 bar R900 709 657 Pressure relief valve (type examinated) DBDS6K1X/330VE R900 768 635

25 402 Pressure relief valve (type examinated) DBDS10K1X/330VE R900 769 274 Pressure relief valve (type examinated) DBDS20K1X/330VE R900 769 365 ADAPTER for electrical connector K4 ON M12X1

for ABZSS..E (electrically actuated accumulator draining)

R901 034 223 ---

3.1.12.4 Accumulator charging valve

Designation (type) Techn. data Order number (manufacturer) Data sheet

DA6VA2A5X/50FSM up to 50 bar; up to 30 l/min; var. switching diff. R901 224 225

26 405 DA6VA2A5X/100FSM up to 100 bar; up to 30 l/min; var. switching diff. R901 224 217

DA6VA2A5X/200FSM up to 200 bar; up to 30 l/min; var. switching diff. R901 224 218

3.1.12.5 Isolator valve with test connection

Designation (type) Techn. data Order number (manufacturer) Data sheet

Isolator valve AB42-02/AMR-PA for safety block; up to 400 bar; G1/2 R900 015 297 AB 42-02

Page 20: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 19 of 41

3.2 Control devices 3.2.1 Directional valves 3.2.1.1 Spool valves – direct operated 3.2.1.1.1 Size 6 – with standard solenoid (DC24V - 30 Watts) and cubic connector

plug-in connector design A according to EN175301-803 w. LED, (must be ordered separately);

3.2.1.1.1.1 Standard Designation (type) Techn. data

Order number (manufacturer) Data sheet

3WE6A6X/EG24N9K4

R900 561 180

23 178

3WE6B6X/EG24N9K4

R900 561 270

4WE6C6X/EG24N9K4

R900 561 272

4WE6D6X/EG24N9K4

R900 561 274

4WE6D6X/OFEG24N9K4

R900 567 512

4WE6E6X/EG24N9K4

R900 561 278

4WE6G6X/EG24N9K4

R900 561 282

4WE6H6X/EG24N9K4

R900 561 286

4WE6HA6X/EG24N9K4

R900 549 534

4WE6J6X/EG24N9K4

R900 561 288

4WE6M6X/EG24N9K4

R900 577 475

4WE6Q6X/EG24N9K4

R900 561 292

4WE6U6X/EG24N9K4

R900 572 785

4WE6Y6X/EG24N9K4

R900 561 276

Page 21: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 20 of 41

3.2.1.1.1.2 Smoothly switching

Designation (type) Techn. data Order number (manufacturer) Data sheet

4WE6D73-6X/EG24N9K4/A12

R900 546 257

23 178

4WE6D73-6X/OFEG24N9K4/A12

R900 567 066

4WE6E73-6X/EG24N9K4/A12

R900 567 095

4WE6G73-6X/EG24N9K4/A12

R900 572 783

4WE6H73-6X/EG24N9K4/A12

R900 906 660

4WE6J73-6X/EG24N9K4/A12

R900 567 997

4WE6U73-6X/EG24N9K4/A12

R900 977 181

4WE6W73-6X/EG24N9K4/A12

R900 567 269

Page 22: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 21 of 41

3.2.1.1.2 Size 6 – solenoid with reduced electric power consumption (DC24V - 8 Watts)

NOTE: Place notice on mounting plate. circular plug-in connector M12x1 according to IEC 61076-2-101 w. LED;

3.2.1.1.2.1 Standard

Designation (type) Techn. data Order number (manufacturer) Data sheet

3WE6A6X/EG24N9K72L SO407

R901 241 328

23 178-00

3WE6B6X/EG24N9K72L SO407

R901 241 330

4WE6C6X/EG24N9K72L SO407

R901 241 335

4WE6D6X/EG24N9K72L SO407

R901 235 380

4WE6D46-6X/OFEG24N9K72L SO407

R901 235 381

4WE6E6X/EG24N9K72L SO407

R901 235 382

4WE6G6X/EG24N9K72L SO407

R901 241 337

4WE6H6X/EG24N9K72L SO407

R901 241 338

4WE6HA6X/EG24N9K72L SO407

R901 241 345

4WE6J6X/EG24N9K72L SO407

R901 235 379

4WE6M6X/EG24N9K72L SO407

R901 241 348

4WE6Q6X/EG24N9K72L SO407

R901 235 367

4WE6U6X/EG24N9K72L SO407

R901 241 349

4WE6Y6X/EG24N9K72L SO407

R901 241 350

Page 23: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 22 of 41

3.2.1.1.2.2 Smoothly switching

Designation (type) Techn. data Order number (manufacturer) Data sheet

4WE6D73-6X/EG24N9K72L SO407

R901 262 594

23 178-00

4WE6D73-6X/OFEG24N9K72L SO407

Upon request

4WE6E73-6X/EG24N9K72L SO407

Upon request

4WE6G73-6X/EG24N9K72L SO407

R901 397 094

4WE6H73-6X/EG24N9K72L SO407

Upon request

4WE6J73-6X/EG24N9K72L SO407

R901 235 389

4WE6U73-6X/EG24N9K72L SO407

Upon request

4WE6W73-6X/EG24N9K72L SO407

R901 243 071

Page 24: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 23 of 41

3.2.1.1.3 Size 10 with standard solenoid (DC24V - 30 Watts) and cubic connector

plug-in connector design A according to EN175301-803 w. LED (must be ordered separately);

3.2.1.1.3.1. Standard

Designation (type) Techn. data Order number (manufacturer) Data sheet

3WE10A5X/OFEG24N9K4/M

R901 350 295

23 340

4WE10D5X/EG24N9K4/M

R901 278 760

4WE10D5X/OFEG24N9K4/M

R901 278 763

4WE10E5X/EG24N9K4/M

R901 278 761

4WE10HA5X/EG24N9K4/M

R901 278 779

4WE10J5X/EG24N9K4/M

R901 278 744

4WE10Q5X/EG24N9K4/M

R901 278 774

3.2.1.1.3.2 Smoothly switching

Designation (type) Techn. data Order number (manufacturer) Data sheet

4WE10D73-5X/EG24N9K4/A12M

R901 341 857

23 340

4WE10D73-5X/OFEG24N9K4/A12M

R901 363 621

4WE10E73-5X/EG24N9K4/A12M

R901 341 853

4WE10H73-5X/EG24N9K4/A12M

R901344561

4WE10J73-5X/EG24N9K4/A12M

R901341855

Page 25: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 24 of 41

3.2.1.1.4 Size 10 – with reduced Size electric power consumption (DC24V - 8 Watts)

Size 10 directional valves are available as pilot operated valves: "SO803“ NOTE: Place notice on mounting plate. circular plug-in connector M12x1 according to IEC 61076-2-101 w. LED;

3.2.1.2 Spool valves – pilot operated Directional valves of the sizes 10 / 16 / 25 / 32 are also available as pilot operated valves. "SO803“ (Pilot valve with reduced electric power consumption – 8 Watts)

3.2.1.2.1 Size 10 – with standard solenoid (DC24V - 30 Watts) and cubic connector plug-in connector design A according to EN175301-803 w. LED, (must be ordered separately);

Designation (type) Techn. data Order number (manufacturer) Data sheet

4WEH10E4X/6EG24N9K4

R900 928 168

24 751 4WEH10Q4X/6EG24N9ETS2K4

R900 710 131

4WEH10Q4X/6EG24N9K4

R900 924 732

3.2.1.2.2 Size 16 – with standard solenoid (DC24V - 30 Watts) and cubic connector

plug-in connector design A according to EN175301-803 w. LED, (must be ordered separately);

Designation (type) Techn. data Order number (manufacturer) Data sheet

4WEH16D7X/6EG24N9ETK4/B10

R900 924 874

24 751

4WEH16HD7X/OF6EG24N9ETK4/B10

R900 966 327

4WEH16E7X/6EG24N9ETK4/B10

R900 923 971

4WEH16J7X/6EG24N9ETK4/B10

R900 930 431

4WEH16Q7X/6EG24N9K4

R900 924 733

Page 26: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 25 of 41

3.2.1.2.3 Size 22/25 – with standard solenoid (DC24V - 30 Watts) and cubic connector

plug-in connector design A according to EN175301-803 w. LED, (must be ordered separately);

Designation (type) Techn. data Order number (manufacturer) Data sheet

4WEH22R7X/6EG24N9ES2K4/B10

R900 956 553

24 751

H-WEH25D6X/6EG24N9ETK4/B10D3

R900 974 494

3.2.1.2.4 Size 32 – with standard solenoid (DC24V - 30 Watts) and cubic connector

plug-in connector design A according to EN175301-803 w. LED, (must be ordered separately);

Designation (type) Techn. data Order number (manufacturer) Data sheet

4WEH32R6X/6EG24N9ES2K4/B10

R900 976 198 24 751

3.2.1.3 Size 6 poppet valves – standard solenoid (DC24V - 30 Watts)

leak-free – operating pressure up to 350 bar,

plug-in connector design A according to EN175301-803 w. LED, (must be ordered separately);

Designation (type) Techn. data Order number (manufacturer) Data sheet

M-3SED6CK1X/350CG24N9K4

R900 052 392

22 049

M-3SED6UK1X/350CG24N9K4/B18

R900 224 607

Page 27: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 26 of 41

3.2.1.4 Size 6 high flow poppet valves – w. standard solenoid (DC24V - 30 Watt)

leak free– operating pressure up to 400 bar, max. flow 25 L/min plug-in connector design A according to EN175301-803 w. LED, (must be ordered separately);

Bezeichnung (Typ) Techn. Daten

Bestellnummer (Hersteller) Datenblatt

4SEC6E2X/G24N9K4./P XXX

Weitere Angaben für das Rückschlagventil bzw. die erforderliche Einstelldrossel/-blende siehe Katalog RD 22 028

4SEC6EB2X/G24N9K4./P XXX

4SEC6E2X/G24N9K4

R901 509 281

4SEC6EB2X/G24N9K4

R901 509 299

Page 28: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 27 of 41

3.2.2 Isolator valves 3.2.2.1 Check valves 3.2.2.1.1 Inline valves

Designation (type) Techn. data Order number (manufacturer) Data sheet

S 6 A05-1X/450J3 up to 420bar; up to 18 l/min; 1 bar spring R901 454 046

20 378

S 8 A05-1X/450J3 up to 420bar; up to 36 l/min; 1 bar spring R901 454 052 S 10 A05-1X/450J3 up to 420bar; up to 60 l/min; 1 bar spring R901 424 189 S 15 A00-1X/450J3 up to 420bar; up to 150 l/min; without spring R901 454 063 S 15 A05-1X/450J3 up to 420bar; up to 150 l/min; 1 bar spring R901 454 065 S 15 A50-1X/450J3 up to 420bar; up to 150 l/min; 5 bar spring R901 454 069 S 20 A05-1X/450J3 up to 420bar; up to 180 l/min; 1 bar spring R901 424 190 S 20 A50-1X/450J3 up to 420bar; up to 180 l/min; 5 bar spring R901 454 076 S 25 A05-1X/420J3 up to 420bar; up to 350 l/min; 1 bar spring R901 454 079 S 30 A05-1X/420J3 up to 420bar; up to 450 l/min; 1 bar spring R901 454 090 S 30 A50-1X/420J3 up to 420bar; up to 450 l/min; 5 bar spring R901 454 094

3.2.2.1.2 Subplate mounted valves

Designation (type) Techn. data Order number (manufacturer) Data sheet

SL10GA1-4X/ up to 315 bar; up to 150 l/min; with pre-opening + leakage oil connection R900 483 370

21 468

SL10GB1-4X/100 up to 315 bar; up to 150 l/min; without pre-opening + leakage oil connection R900 451 135

SL20GA1-4X/ up to 315 bar; up to 350 l/min; with pre-opening + leakage oil connection R900 587 554

SL30GA1-4X/ up to 315 bar; up to 550 l/min; with pre-opening + leakage oil connection R900 587 556

SV10GA1-4X/ up to 315 bar; up to 150 l/min; with pre-opening R900 483 368

SV20GA1-4X/ up to 315 bar; up to 350 l/min; with pre-opening R900 587 550

3.2.2.1.3 Sandwich plate valves 3.2.2.1.3.1 Size 6

Designation (type) Techn. data Order number (manufacturer) Data sheet

Z1S6F05-4X/N up to 315 bar; up to 40 l/min; check valve in P+T; spring 0.5 bar: R901 441 521

21 534

Z1S6F30-4X/N up to 315 bar; up to 40 l/min; check valve in P+T; spring 3 bar: Upon request

Z1S6P05-4X/N up to 315 bar; up to 40 l/min; check valve in P; spring 0.5 bar: R901 152 381

Z1S6P30-4X/N up to 315 bar; up to 40 l/min; check valve in P; spring 3 bar: R901 416 890

Z1S6T05-4X/N up to 315 bar; up to 40 l/min; check valve in T; spring 0.5 bar: R901 312 739

Z1S6T30-4X/N up to 315 bar; up to 40 l/min; check valve in T; spring 3 bar: R901 152 370

Z2S6-1-6X/ up to 315 bar; up to 60 l/min; in channels A+B; spring 1.5 bar R900 347 495

21 548 Z2S6A1-6X/ up to 315 bar; up to 60 l/min; in channel A; spring 1.5 bar R900 347 498

Z2S6B1-6X/ up to 315 bar; up to 60 l/min; in channel B; spring 1.5 bar R900 347 501

Page 29: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 28 of 41

3.2.2.1.3.2 Size 10 Techn. data

Order number (manufacturer) Data sheet

Z1S10P05-1-4X/N up to 315 bar; up to 100 l/min; check valve in P; spring 0.5 bar: R901 285 818

21 537 Z1S10P30-1-4X/N up to 315 bar; up to 100 l/min; check valve in

P; spring 3 bar: Upon request

Z1S10TA05-2TB9-4X/N up to 315 bar; up to 100 l/min; check valve in T; spring 0.5 bar: R901 274 777

Z1S10TA30-2TB9-4X/N up to 315 bar; up to 100 l/min; check valve in T;spring 3 bar: R901 465 075

Z2S10-1-3X/ up to 315 bar; up to 120 l/min; in channels A+B; spring 1.5 bar R900 407 394

21 553 Z2S10A1-3X/ up to 315 bar; up to 120 l/min; in channel A; spring 1.5 bar R900 407 424

Z2S10B1-3X/ up to 315 bar; up to 120 l/min; in channel B; spring 1.5 bar R900 407 434

3.2.3 Pressure valves 3.2.3.1 Pressure relief valves 3.2.3.1.1 Direct operated valves

3.2.3.1.1.1 Subplate mounted valves Size 6

Designation (type) Techn. data Order number (manufacturer) Data sheet

DBDS6P1X/25 up to 25 bar; up to 50 l/min R900 429 414

25 402

DBDS6P1X/50 up to 50 bar; up to 50 l/min R900 423 732 DBDS6P1X/100 up to 100 bar; up to 50 l/min R900 423 728 DBDS6P1X/200 up to 200 bar; up to 50 l/min R900 423 729 DBDA6P1X/25 up to 25 bar; up to 50 l/min R900 432 567 DBDA6P1X/50 up to 50 bar; up to 50 l/min R900 428 300 DBDA6P1X/100 up to 100 bar; up to 50 l/min R900 425 084 DBDA6P1X/200 up to 200 bar; up to 50 l/min R900 430 459

Size 10 Designation (type) Techn. data

Order number (manufacturer) Data sheet

DBDS10P1X/25 up to 25 bar; up to 120 l/min R900 426 905

25 402

DBDS10P1X/50 up to 50 bar; up to 120 l/min R900 425 661 DBDS10P1X/100 up to 100 bar; up to 120 l/min R900 424 155 DBDS10P1X/200 up to 200 bar; up to 120 l/min R900 424 157 DBDA10P1X/25 up to 25 bar; up to 120 l/min R900 431 570 DBDA10P1X/50 up to 50 bar; up to 120 l/min R900 428 389 DBDA10P1X/100 up to 100 bar; up to 120 l/min R900 423 867 DBDA10P1X/200 up to 200 bar; up to 120 l/min R900 425 968

Size 20

Designation (type) Techn. data Order number (manufacturer) Data sheet

DBDS20P1X/25 up to 25 bar; up to 250 l/min R900 430 311

25 402

DBDS20P1X/50 up to 50 bar; up to 250 l/min R900 424 272 DBDS20P1X/100 up to 100 bar; up to 250 l/min R900 424 274 DBDS20P1X/200 up to 200 bar; up to 250 l/min R900 424 277 DBDA20P1X/25 up to 25 bar; up to 250 l/min R900 432 406 DBDA20P1X/50 up to 50 bar; up to 250 l/min R900 433 349 DBDA20P1X/100 up to 100 bar; up to 250 l/min R900 430 259 DBDA20P1X/200 up to 200 bar; up to 250 l/min R900 469 245

Page 30: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 29 of 41

3.2.3.1.1.2 Screw-in cartridge valves Size 6

Designation (type) Techn. data Order number (manufacturer) Data sheet

DBDS6K1X/50 up to 50 bar; up to 50 l/min; R900 423 727

25 402

DBDS6K1X/100 up to 100 bar; up to 50 l/min; R900 423 723 DBDS6K1X/200 up to 200 bar; up to 50 l/min; R900 423 724 DBDS6K1X/315 up to 315 bar; up to 50 l/min; R900 423 725 DBDA6K1X/50 up to 50 bar; up to 50 l/min; R900 425 083 DBDA6K1X/100 up to 100 bar; up to 50 l/min; R900 425 080 DBDA6K1X/200 up to 200 bar; up to 50 l/min; R900 425 081 DBDA6K1X/315 up to 315 bar; up to 50 l/min; R900 425 082

Size 10

Designation (type) Techn. data Order number (manufacturer) Data sheet

DBDS10K1X/50 up to 50 bar; up to 120 l/min; R900 424 153

25 402

DBDS10K1X/100 up to 100 bar; up to 120 l/min; R900 424 147 DBDS10K1X/200 up to 200 bar; up to 120 l/min; R900 424 149 DBDS10K1X/315 up to 315 bar; up to 120 l/min; R900 424 150 DBDA10K1X/50 up to 50 bar; up to 120 l/min; R900 425 966 DBDA10K1X/100 up to 100 bar; up to 120 l/min; R900 425 161 DBDA10K1X/200 up to 200 bar; up to 120 l/min; R900 425 162

Size 20

Designation (type) Techn. data Order number (manufacturer) Data sheet

DBDS20K1X/50 up to 50 bar; up to 250 l/min; R900 424 205

25 402

DBDS20K1X/100 up to 100 bar; up to 250 l/min; R900 424 267 DBDS20K1X/200 up to 200 bar; up to 250 l/min; R900 423 269 DBDS20K1X/315 up to 315 bar; up to 250 l/min; R900 424 271 DBDA20K1X/50 up to 50 bar; up to 250 l/min; R900 423 873 DBDA20K1X/100 up to 100 bar; up to 250 l/min; R900 423 871 DBDA20K1X/200 up to 200 bar; up to 250 l/min; R900 430 334 DBDA20K1X/315 up to 315 bar; up to 250 l/min; R900 423 872

3.2.3.1.1.3 Valves for threaded connection Size 6

Designation (type) Techn. data Order number (manufacturer) Data sheet

DBDS6G1X/50 up to 50 bar; up to 50 l/min; R900 423 722

25 402

DBDS6G1X/100 up to 100 bar; up to 50 l/min; R900 423 717 DBDS6G1X/200 up to 200 bar; up to 50 l/min; R900 423 719 DBDS6G1X/315 up to 315 bar; up to 50 l/min; R900 423 720 DBDA6G1X/50 up to 50 bar; up to 50 l/min; R900 424 177 DBDA6G1X/100 up to 100 bar; up to 50 l/min; R900 425 076 DBDA6G1X/200 up to 200 bar; up to 50 l/min; R900 426 477 DBDA6G1X/315 up to 315 bar; up to 50 l/min; R900 426 478

Page 31: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 30 of 41

Size 10

Designation (type) Techn. data Order number (manufacturer) Data sheet

DBDS10G1X/50 up to 50 bar; up to 120 l/min; R900 424 745

25 402

DBDS10G1X/100 up to 100 bar; up to 120 l/min; R900 424 738 DBDS10G1X/200 up to 200 bar; up to 120 l/min; R900 424 140 DBDS10G1X/315 up to 315 bar; up to 120 l/min; R900 424 742 DBDA10G1X/50 up to 50 bar; up to 120 l/min; R900 469 298 DBDA10G1X/100 up to 100 bar; up to 120 l/min; R900 423 860 DBDA10G1X/200 up to 200 bar; up to 120 l/min; R900 423 866 DBDA10G1X/315 up to 315 bar; up to 120 l/min; R900 424 176

Size 20

Designation (type) Techn. data Order number (manufacturer) Data sheet

DBDS20G1X/50 up to 50 bar; up to 250 l/min; R900 424 276

25 402

DBDS20G1X/100 up to 100 bar; up to 250 l/min; R900 424 170 DBDS20G1X/200 up to 200 bar; up to 250 l/min; R900 424 172 DBDA20G1X/50 up to 50 bar; up to 250 l/min; R900 423 870 DBDA20G1X/100 up to 100 bar; up to 250 l/min; R900 436 044 DBDA20G1X/200 up to 200 bar; up to 250 l/min; R900 438 012

Page 32: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 31 of 41

3.2.3.1.1.4 Sandwich plate valves Size 6

Designation (type) Techn. data Order number (manufacturer) Data sheet

ZDB6VA2-4X/50 up to 50 bar; up to 60 l/min; in channel A R900 431 678

25 751

ZDB6VB2-4X/50 up to 50 bar; up to 60 l/min; in channel B R900 430 645 ZDB6VP2-4X/50 up to 50 bar; up to 60 l/min; in channel P R900 432 804 ZDB6VA2-4X/100 up to 100 bar; up to 60 l/min; in channel A R900 437 441 ZDB6VB2-4X/100 up to 100 bar; up to 60 l/min; in channel B R900 431 401 ZDB6VP2-4X/100 up to 100 bar; up to 60 l/min; in channel P R900 423 274 ZDB6VA2-4X/200 up to 200 bar; up to 60 l/min; in channel A R900 426 329 ZDB6VB2-4X/200 up to 200 bar; up to 60 l/min; in channel B R900 429 509 ZDB6VP2-4X/200 up to 200 bar; up to 60 l/min; in channel P R900 428 339 HSZ06A100-3X/S025M00 Sandwich plate with pressure relief function P->T R900 936 130 48 050 ZDB6VA3-4X/50 up to 50 bar; up to 60 l/min; in channel A R900 425 683

25 751

ZDB6VB3-4X/50 up to 50 bar; up to 60 l/min; in channel B R900 438 971 ZDB6VP3-4X/50 up to 50 bar; up to 60 l/min; in channel P R900 432 112 ZDB6VA3-4X/100 up to 100 bar; up to 60 l/min; in channel A R900 428 435 ZDB6VB3-4X/100 up to 100 bar; up to 60 l/min; in channel B R900 431 167 ZDB6VP3-4X/100 up to 100 bar; up to 60 l/min; in channel P R900 460 711 ZDB6VA3-4X/200 up to 200 bar; up to 60 l/min; in channel A R900 438 967 ZDB6VB3-4X/200 up to 200 bar; up to 60 l/min; in channel B R900 465 884 ZDB6VP3-4X/200 up to 200 bar; up to 60 l/min; in channel P R900 422 089

Size 10 ZDB10VA2-4X/50 up to 50 bar; up to 100 l/min; in channel A R900 432 106

25 761

ZDB10VB2-4X/50 up to 50 bar; up to 100 l/min; in channel B R900 967 525 ZDB10VP2-4X/50 up to 50 bar; up to 100 l/min; in channel P R900 440 098 ZDB10VA2-4X/100 up to 100 bar; up to 100 l/min; in channel A R900 427 434 ZDB10VB2-4X/100 up to 100 bar; up to 100 l/min; in channel B R900 422 073 ZDB10VP2-4X/100 up to 100 bar; up to 100 l/min; in channel P R900 431 065 ZDB10VA2-4X/200 up to 200 bar; up to 100 l/min; in channel A R900 421 265 ZDB10VB2-4X/200 up to 200 bar; up to 100 l/min; in channel B R900 422 261 ZDB10VP2-4X/200 up to 200 bar; up to 100 l/min; in channel P R900 428 468 HSZ10A100-3X/M00 Sandwich plate with pressure relief function P->T R900 526 220 48 052 ZDB10VA3-4X/50 up to 50 bar; up to 100 l/min; in channel A R900 425 958

25 761

ZDB10VB3-4X/50 up to 50 bar; up to 100 l/min; in channel B Upon request ZDB10VP3-4X/50 up to 50 bar; up to 100 l/min; in channel P R900 460 358 ZDB10VA3-4X/100 up to 100 bar; up to 100 l/min; in channel A R900 906 981 ZDB10VB3-4X/100 up to 100 bar; up to 100 l/min; in channel B R900 580 968 ZDB10VP3-4X/100 up to 100 bar; up to 100 l/min; in channel P R900 522 880 ZDB10VA3-4X/200 up to 200 bar; up to 100 l/min; in channel A R900 449 071 ZDB10VB3-4X/200 up to 200 bar; up to 100 l/min; in channel B Upon request ZDB10VP3-4X/200 up to 200 bar; up to 100 l/min; in channel P R900 439 335

Page 33: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 32 of 41

3.2.3.1.2 Pilot operated

3.2.3.1.2.1 Subplate mounted valves Size 20

Designation (type) Techn. data Order number (manufacturer) Data sheet

DB20-2-5X/200XY up to 200 bar; up to 500 l/min; R900 500 218

25 802 DB20-2-5X/50 up to 50 bar; up to 500 l/min; R900 597 212 DB30-2-5X/50 up to 50 bar; up to 650 l/min; R900 593 564 DB20-3-5X/200XY up to 200 bar; up to 500 l/min; R900 566 474 DB20-3-5X/50 up to 50 bar; up to 500 l/min; R900 502 708

Size 30

Designation (type) Techn. data Order number (manufacturer) Data sheet

DB30-3-5X/50 up to 50 bar; up to 650 l/min; R900 520 557 25 802

Page 34: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 33 of 41

3.2.3.1.2.2 Screw-in cartridge valves Size 6

Designation (type) Techn. data Order number (manufacturer) Data sheet

DB6K2-4X/50Y up to 50 bar; up to 100 l/min; R900 425 998

25 731

DB6K2-4X/100Y up to 100 bar; up to 100 l/min; R900 408 060 DB6K2-4X/200Y up to 200 bar; up to 100 l/min; R900 422 238 DB6K3-4X/50Y up to 50 bar; up to 100 l/min; R900 424 554 DB6K3-4X/100Y up to 100 bar; up to 100 l/min; R900 426 666 DB6K3-4X/200Y up to 200 bar; up to 100 l/min; R900 424 552

Size 10 Designation (type) Techn. data

Order number (manufacturer) Data sheet

DB10K2-4X/50Y up to 50 bar; up to 100 l/min; R900 408 654

25 731 DB10K2-4X/100Y up to 100 bar; up to 100 l/min; R900 430 681 DB10K2-4X/200Y up to 200 bar; up to 100 l/min; R900 481 084 DB10K3-4X/50Y up to 50 bar; up to 100 l/min; R900 427 508 DB10K3-4X/100Y up to 100 bar; up to 100 l/min; R900 580 081 DB10K3-4X/200Y up to 200 bar; up to 100 l/min; R900 440 572

Size 20 Designation (type) Techn. data

Order number (manufacturer) Data sheet

DB20K2-1X/100XY up to 100 bar; up to 300 l/min; R900 470 297

25 818 DB20K2-1X/200XY up to 200 bar; up to 300 l/min; R900 470 298 DB20K3-1X/100XY up to 100 bar; up to 300 l/min; R900 402 736 DB20K3-1X/200XY up to 200 bar; up to 300 l/min; R900 493 310

3.2.3.1.2.3 Switchable – with standard solenoid (DC24V - 30 Watts) plug-in connector design A according to EN175301-803 w. LED, (must be ordered separately);

Designation (type) Techn. data Order number (manufacturer) Data sheet

DBW10B2-5X/50-6EG24N9K4 up to 50 bar; up to 250 l/min; switchable R900 921 748 25 802 DBW10B3-5X/50-6EG24N9K4 up to 50 bar; up to 250 l/min; switchable R900 908 998

3.2.3.1.2.4 Switchable – solenoid with reduced electric power consumption NOTE: Place notice on mounting plate. DC24V; circular plug-in connector M12x1 according to IEC 61076-2-101 w. LED;

Designation (type) Techn. data Order number (manufacturer) Data sheet

DBW10B2-5X/50-6EG24N9K72L SO803 up to 50 bar; up to 250 l/min; switchable Upon request 25 802 DBW10B3-5X/50-6EG24N9K72L SO803 up to 50 bar; up to 250 l/min; switchable R901 358 183

Page 35: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 34 of 41

3.2.3.2 Pressure reducing valves 3.2.3.2.1 Direct operated 3.2.3.2.1.1 Subplate mounted valves Size 6

Designation (type) Techn. data Order number (manufacturer) Data sheet

DR6DP2-5X/25Y up to 25 bar; up to 60 l/min; with check v. R900 465 254

26 564

DR6DP2-5X/75YM up to 75 bar; up to 60 l/min; without check v. R900 450 964 DR6DP2-5X/75Y up to 75 bar; up to 60 l/min; with check v. R900 413 241 DR6DP2-5X/150Y up to 150 bar; up to 60 l/min; with check v. R900 413 242 DR6DP2-5X/210Y up to 210 bar; up to 60 l/min; with check v. R900 413 243 DR6DP3-5X/25Y up to 25 bar; up to 60 l/min; with check v. R900 479 794 DR6DP3-5X/75Y up to 75 bar; up to 60 l/min; with check v. R900 469 279 DR6DP3-5X/75YM up to 75 bar; up to 60 l/min; without check v. R900 472 420 DR6DP3-5X/150Y up to 150 bar; up to 60 l/min; with check v. R900 479 809 DR6DP3-5X/210Y up to 210 bar; up to 60 l/min; with check v. R900 478 697

Size 10

Designation (type) Techn. data Order number (manufacturer) Data sheet

DR10DP2-4X/75Y up to 75 bar; up to 80 l/min; with check v. R900 500 471

26 580 DR10DP2-4X/210Y up to 210 bar; up to 80 l/min; with check v. R900 594 125 DR10DP3-4X/75Y up to 75 bar; up to 80 l/min; with check v. R900 502 655 DR10DP3-4X/210Y up to 210 bar; up to 80 l/min; with check v. R900 500 903

Size 16

Designation (type) Techn. data Order number (manufacturer) Data sheet

3DR 16 P5-5X/100Y/00M up to 100bar; up to 220l/min; without check v.; R900 916 666 26 928

Page 36: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 35 of 41

3.2.3.2.1.2 Sandwich plate valves

Size 6

Designation (type) Techn. data Order number (manufacturer) Data sheet

ZDR6DA2-4X/25YM up to 25 bar; up to 50 l/min; in channel A; without check v. R900 448 079

26 570

ZDR6DA2-4X/25Y up to 25 bar; up to 50 l/min; in channel A; with check v. R900 410 808 ZDR6DA2-4X/75YM up to 75 bar; up to 50 l/min; in channel A; without check v. R900 410 815 ZDR6DA2-4X/75Y up to 75 bar; up to 50 l/min; in channel A; with check v. R900 410 813 ZDR6DA2-4X/150YM up to 150 bar; up to 80 l/min; in channel A; without check v. R900 445 958 ZDR6DA2-4X/150Y up to 150 bar; up to 50 l/min; in channel A; with check v. R900 410 849 ZDR6DA2-4X/210YM up to 210 bar; up to 50 l/min; in channel A; without check v. R900 423 213 ZDR6DA2-4X/210Y up to 210 bar; up to 50 l/min; in channel A; with check v. R900 410 855 ZDR6DB2-4X/25YM up to 25 bar; up to 50 l/min; in channel B; without check v. R900 449 839 ZDR6DB2-4X/75YM up to 75 bar; up to 50 l/min; in channel B; without check v. R900 431 771 ZDR6DB2-4X/150YM up to 150 bar; up to 50 l/min; in channel B; without check v. R900 431 172 ZDR6DB2-4X/210YM up to 210 bar; up to 50 l/min; in channel B; without check v. R900 463 269 ZDR6DP2-4X/25YM up to 25 bar; up to 50 l/min; in channel P; without check v. R900 483 785 ZDR6DP2-4X/75YM up to 75 bar; up to 50 l/min; in channel P; without check v. R900 483 786 ZDR6DP2-4X/150YM up to 150 bar; up to 50 l/min; in channel P; without check v. R900 483 787 ZDR6DP2-4X/210YM up to 210 bar; up to 50 l/min; in channel P; without check v. R900 483 788 ZDR6DA3-4X/25YM up to 25 bar; up to 50 l/min; in channel A; without check v. R900 455 586 ZDR6DA3-4X/25Y up to 25 bar; up to 50 l/min; in channel A; with check v. R900 448 490 ZDR6DA3-4X/75YM up to 75 bar; up to 50 l/min; in channel A; without check v. R900 421 983 ZDR6DA3-4X/75Y up to 75 bar; up to 50 l/min; in channel A; with check v. R900 410 864 ZDR6DA3-4X/150YM up to 150 bar; up to 80 l/min; in channel A; without check v. R900 477 431 ZDR6DA3-4X/150Y up to 150 bar; up to 50 l/min; in channel A; with check v. R900 445 998 ZDR6DA3-4X/210YM up to 210 bar; up to 50 l/min; in channel A; without check v. R900 479 783 ZDR6DA3-4X/210Y up to 210 bar; up to 50 l/min; in channel A; with check v. R900 424 371 ZDR6DB3-4X/25YM up to 25 bar; up to 50 l/min; in channel B; without check v. R900 425 957 ZDR6DB3-4X/75YM up to 75 bar; up to 50 l/min; in channel B; without check v. R900 432 119 ZDR6DB3-4X/150YM up to 150 bar; up to 50 l/min; in channel B; without check v. R900428 322 ZDR6DB3-4X/210YM up to 210 bar; up to 50 l/min; in channel B; without check v. R900 512 864 ZDR6DP3-4X/25YM up to 25 bar; up to 50 l/min; in channel P; without check v. R900 476 274 ZDR6DP3-4X/75YM up to 75 bar; up to 50 l/min; in channel P; without check v. R900 410 865 ZDR6DP3-4X/150YM up to 150 bar; up to 50 l/min; in channel P; without check v. R900 473 199 ZDR6DP3-4X/210YM up to 210 bar; up to 50 l/min; in channel P; without check v. R900 481 115

Page 37: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 36 of 41

Size 10

Designation (type) Techn. data Order number (manufacturer) Data sheet

ZDR10DA2-5X/25YM up to 25 bar; up to 80 l/min; in channel A; without check v. R900 422 337

26 585

ZDR10DA2-5X/25Y up to 25 bar; up to 80 l/min; in channel A; with check v. R900 407 334 ZDR10DA2-5X/75YM up to 75 bar; up to 80 l/min; in channel A; without check v. R900 494 714 ZDR10DA2-5X/75Y up to 75 bar; up to 80 l/min; in channel A; with check v. R900 438 008 ZDR10DA2-5X/150YM up to 150 bar; up to 80 l/min; in channel A; without check v. R900 406 225 ZDR10DA2-5X/150Y up to 150 bar; up to 80 l/min; in channel A; with check v. R900 410 884 ZDR10DA2-5X/210YM up to 210 bar; up to 80 l/min; in channel A; without check v. R900 428 474 ZDR10DA5-5X/210Y up to 210 bar; up to 80 l/min; in channel A; with check v. R900 406 651 ZDR10DB2-5X/25YM up to 25 bar; up to 80 l/min; in channel B; without check v. R900 426 202 ZDR10DB2-5X/75YM up to 75 bar; up to 80 l/min; in channel B; without check v. R900 431 509 ZDR10DB2-5X/150YM up to 150 bar; up to 80 l/min; in channel B; without check v. R900 408 340 ZDR10DB2-5X/210YM up to 210 bar; up to 80 l/min; in channel B; without check v. R900 443 484 ZDR10DP2-5X/25YM up to 25 bar; up to 80 l/min; in channel P; without check v. R900 410 899 ZDR10DP2-5-5X/75YM up to 75 bar; up to 80 l/min; in channel P; without check v. R900 410 875 ZDR10DP2-5X/150YM up to 150 bar; up to 80 l/min; in channel P; without check v. R900 410 880 ZDR10DP2-5X/210YM up to 210 bar; up to 80 l/min; in channel P; without check v. R900 410 876 ZDR10DA3-5X/25YM up to 25 bar; up to 80 l/min; in channel A; without check v. R900 477 791 ZDR10DA3-5X/25Y up to 25 bar; up to 80 l/min; in channel A; with check valve R900 406 335 ZDR10DA3-5X/75YM up to 75 bar; up to 80 l/min; in channel A; without check v. R900 426 703 ZDR10DA3-5X/75Y up to 75 bar; up to 80 l/min; in channel A; with check v. R900 411 259 ZDR10DA3-5X/150YM up to 150 bar; up to 80 l/min; in channel A; without check v. R900 464 178 ZDR10DA3-5X/150Y up to 150 bar; up to 80 l/min; in channel A; with check v. R900 429 570 ZDR10DA3-5X/210YM up to 210 bar; up to 80 l/min; in channel A; without check v. R900 440 715 ZDR10DA3-5X/210Y up to 210 bar; up to 80 l/min; in channel A; with check v. R900 409 515 ZDR10DB3-5X/25YM up to 25 bar; up to 80 l/min; in channel B; without check v. R900 431 392 ZDR10DB3-5X/75YM up to 75 bar; up to 80 l/min; in channel B; without check v. R900 472 027 ZDR10DB3-5X/150YM up to 150 bar; up to 80 l/min; in channel B; without check v. R900 471 974 ZDR10DB3-5X/210YM up to 210 bar; up to 80 l/min; in channel B; without check v. R900 519 131 ZDR10DP3-5X/25YM up to 25 bar; up to 80 l/min; in channel P; without check v. R900 481 806 ZDR10DP3-5X/75YM up to 75 bar; up to 80 l/min; in channel P; without check v. R900 411 255 ZDR10DP3-5X/150YM up to 150 bar; up to 80 l/min; in channel P; without check v. R900 493 965 ZDR10DP3-5X/210YM up to 210 bar; up to 80 l/min; in channel P; without check v. R900 401 090

3.2.3.2.2 Pilot operated Size 10

Designation (type) Techn. data Order number (manufacturer) Data sheet

DR10-5-5X/50YM up to 50 bar; up to 150 l/min; without check v. R900 598 359

26 892 DR10-5-5X/200YM up to 200 bar; up to 150 l/min; without check v. R900 598 358 DR10-6-5X/50YM up to 50 bar; up to 150 l/min; without check v. R900 501 378 DR10-6-5X/200YM up to 200 bar; up to 150 l/min; without check v. R900 503 981

Size 20

Designation (type) Techn. data Order number (manufacturer) Data sheet

DR20-5-5X/200YM up to 200 bar; up to 300 l/min; without check v. R900 597 233 26 892 DR20-6-5X/200YM up to 200 bar; up to 300 l/min; without check v. R900 599 017

Page 38: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 37 of 41

3.2.3.2.3 Pressure sequencing valves Size 6

Designation (type) Techn. data Order number (manufacturer) Data sheet

DZ6DP2-5X/75YM up to 75 bar; up to 60 l/min; without check valve R900 485 007

26 076

DZ6DP2-5X/150YM up to 150 bar; up to 60 l/min; without check valve R900 407 721 DZ6DP2-5X/210YM up to 210 bar; up to 60 l/min; without check valve R900 481 316 DZ6DP3-5X/75YM up to 75 bar; up to 60 l/min; without check valve R900 478 933 DZ6DP3-5X/150YM up to 150 bar; up to 60 l/min; without check valve R900 400 921 DZ6DP3-5X/210YM up to 210 bar; up to 60 l/min; without check valve R900 525 378

Size 10

Designation (type) Techn. data Order number (manufacturer) Data sheet

DZ10DP2-4X/75YM up to 75 bar; up to 80 l/min; without check valve R900 500 987

26 099

DZ10DP2-4X/150YM up to 150 bar; up to 80 l/min; without check valve R900 505 068 DZ10DP2-4X/210Y up to 210 bar; up to 80 l/min; with check valve R900 599 686 DZ10DP3-4X/75YM up to 75 bar; up to 80 l/min; without check valve R900 501 591 DZ10DP3-4X/150YM up to 150 bar; up to 80 l/min; without check valve R900 503 118 DZ10DP3-4X/210Y up to 210 bar; up to 80 l/min; with check valve R900 956 907

3.2.4 Flow control valves 3.2.4.1 Throttle valves 3.2.4.1.1 Pipe fitting

Designation (type) Techn. data Order number (manufacturer) Data sheet

MG6G1X/V up to 315bar; up to 15l/min; G1/4; R900 437 338

27 219

MG8G1X/V up to 315bar; up to 30l/min; G3/8; R900 438 885 MG10G1X/V up to 315bar; up to 50l/min; G1/2; R900 422 145 MG15G1X/V up to 315bar; up to 125l/min; G3/4; R900 437 653 MG20G1X/V up to 315bar; up to 200l/min; G1; R900 422 150 MG25G1X/V up to 315bar; up to 300l/min; G1 1/4; R900 413 979 MG30G1X/V up to 315bar; up to 400l/min; G1 1/2; R900 422 153

3.2.4.2 Throttle check valves 3.2.4.2.1 Pipe fitting

Designation (type) Techn. data Order number (manufacturer) Data sheet

MK6G1XV/ up to 315bar; up to 15l/min; G1/4; R900 423 340

27 219

MK8G1X/V up to 315bar; up to 30l/min; G3/8; R900 423 343 MK10G1X/V up to 315bar; up to 50l/min; G1/2; R900 424 579 MK15G1X/V up to 315bar; up to 125l/min; G3/4; R900 423 326 MK20G1X/V up to 315bar; up to 200l/min; G1; R900 223 328 MK25G1X/V up to 315bar; up to 300l/min; G1 1/4; R900 423 330 MK30G1X/V up to 315bar; up to 400l/min; G1 1/2; R900 423 333 DRV-06-1-1X/V up to 350bar; up to 20l/min; G1/8; R900 356 590

32 502

DRV-08-1-1X/V up to 350bar; up to 50l/min; G1/4; R900 450 170 DRV-10-1-1X/V up to 350bar; up to 60l/min; G3/8; R900 450 171 DRV-12-1-1X/V up to 350bar; up to 90l/min; G1/2; R900 450 172 DRV-16-1-1X/V up to 350bar; up to 180l/min; G3/4; R900 450 173 DRV-20-1-1X/V up to 350bar; up to 300l/min; G1; R900 489 123

Page 39: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 38 of 41

3.2.4.2.2 Sandwich plate valves Size 6

Designation (type) Techn. data Order number (manufacturer) Data sheet

Z2FS6A2-4X/2Q up to 315 bar; up to 80 l/min; in channel A; discharge throttle. R900 427 254

27 506

Z2FS6B2-4X/2Q up to 315 bar; up to 80 l/min; in channel B; discharge throttle. R900 423 224

Z2FS6-2-4X/2Q up to 315 bar; up to 80 l/min; in channel A+B R900 481 622

Z2FS6A3-4X/2Q up to 315 bar; up to 80 l/min; in channel A; discharge throttle. R901 482 975

Z2FS6B3-4X/2Q up to 315 bar; up to 80 l/min; in channel B; discharge throttle. R901 482 977

Z2FS6-3-4X/2Q up to 315 bar; up to 80 l/min; in channel A+B R900 434 395 Sizes 10 and 16

Designation (type) Techn. data Order number (manufacturer) Data sheet

Z2FS10-5-3X/ up to 315 bar; up to 160 l/min; in channel A+B R900 989 095

27 518 Z2FS10A5-3X/S2 up to 315 bar; up to 160 l/min; in channel A; discharge

throttle. R900 571 890

Z2FS10B5-3X/S2 up to 315 bar; up to 160 l/min; in channel B; discharge throttle. R900 989 106

Z2FS16-3X/S2 up to 350 bar; up to 250 l/min; in channel A+B R900 457 256

3.2.4.3 Flow control valves 3.2.4.3.1 Subplate mounted valves Size 6

Designation (type) Techn. data Order number (manufacturer) Data sheet

2FRM6B36-3X/1,5QMV up to 315bar; up to 1,5l/min; o. RV R900 205 506

28 163

2FRM6B36-3X/1,5QRV up to 315bar; up to 1,5l/min; m. RV R900 205 507 2FRM6B36-3X/3QMV up to 315bar; up to 3l/min; o. RV R900 205 516 2FRM6B36-3X/3QRV up to 315bar; up to 3l/min; m. RV R900 205 517 2FRM6B36-3X/6QMV up to 315bar; up to 6l/min; o. RV R900 205 518 2FRM6B36-3X/6QRV up to 315bar; up to 6l/min; m. RV R900 205 519

Size 10

Designation (type) Techn. data Order number (manufacturer) Data sheet

2FRM10-3X/25LB up to 315 bar; up to 25 l/min; R900 423 256 28 389 2FRM10-3X/50LB up to 315 bar; up to 50 l/min; R900 423 261 3.2.4.3.2 Sandwich plate valves

Designation (type) Techn. data Order number (manufacturer) Data sheet

Z2FRM6AB2-2X/6QRV up to 315 bar, up to 6 l/min, in Kanal A, m. RV R900 910 906

28 164

Z2FRM6AB2-2X/32QRV up to 315 bar, up to 32 l/min, in Kanal A, m. RV R900 549 689 Z2FRM6BB2-2X/6QRV up to 315 bar, up to 6 l/min, in Kanal B, m. RV R900 910 905 Z2FRM6BB2-2X/32QRV up to to 315 bar, up to 32 l/min, in Kanal B, m. RV R900 549 688 Z2FRM6CB2-2X/6QRV up to 315 bar, up to 6 l/min, in Kanal A+B, m. RV R900 910 904 Z2FRM6CB2-2X/32QRV up to 315 bar, up to bis 32 l/min, in Kanal A+B, m. RV R900 549 687 Z2FRM6TB2-2X/6QRV up to 315 bar, up to 6 l/min, in Kanal T, m. RV R900 910 912 Z2FRM6TB2-2X/32QRV up to 315 bar, up to 32 l/min, in Kanal T, m. RV R900 908 807

Page 40: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1 Page 39 of 41

3.2.4.3.3 Screw-in cartridge valves Size 6

Designation (type) Techn. data Order number (manufacturer) Data sheet

2FRM6K2-1X/6QRV up to 315bar; up to 6l/min; R900 905 886 28 155 2FRM6K2-1X/32QRV up to 315bar; up to 32l/min; R900 572 182 Size 10

Designation (type) Techn. data Order number (manufacturer) Data sheet

2FRM10K2-1X/60QRV up to 315bar; up to 60l/min; R900 985 448 28 155

3.3 Cylinders 3.3.1 Tie rod cylinders

Piston rod with square, with drain port if required Designation (type) Techn. data

Order number (manufacturer) Data sheet

CDT3....3X/...H…E…B… 160 bar; Pistons 25-200 mm; rods 12-140 mm XXXX XXX XXX

17 049 CGT3….3X/...H…E…B… 160 bar;

Pistons 25-200 mm; rods 12-140 mm XXXX XXX XXX

H = Piston rod hardened and hard chromium-plated E = End position cushioning adjustable on both sides B = with leakage oil connection (only for concealed cylinders)

3.4 Accessories

3.4.1 Adapter and cover plates

3.4.1.1 Adapter for mating connector

Designation (type) Techn. data Order number (manufacturer) Data sheet

Adapter K4 on M12x1 For ABZSS..E (electr. operated accumulator discharging)

R901 034 223 ---

3.4.1.2 Cover plates

Designation (type) Techn. data Order number (manufacturer) Data sheet

HSA06A064-3X/M00 Cover plate with pressure relief function P-T R900 579 914

Page 41: Approved Components List Mechanical ... - Robert Bosch GmbH...The Global Account Management, division DC-AE/SMP12, of Bosch Rexroth AG is responsible for the creation and maintenance

Page 40 of 41

Bosch_Rexroth_AG_Freigabeliste_VW_Components_Hydraulik_20200101_en.docx Version 2.2 / 01.01.2020 KSU-Klasse 6.1

4 Data sheets - not specified

5 Systems with flame-resistant hydraulic fluids of the HFC group

Hydraulic components for systems using hydraulic fluids of the HFC group (water glycol, reference oil "Ultrasafe 620 VW Kassel") according to DIN EN ISO 12922 or VDMA 24317 are listed in the approved components list for foundry production of the VOLKSWAGEN group.