arealux al90 example light plan
DESCRIPTION
AREALUX is the ultimate Led flood lighting for illuminating large areas. AREALUX is a retrofit solution for mast height of 12 to 45 metres. Here you have the an example of a lightplan for the AREALUX. AL-90. Aplication: container terminals, parking lots, industrial plants, factories, airports, harbours, marshaliing yards. Its an energy efficient solution fully controllable by a light management system, that improves safety and productivity. By continous luminaire monitoring efficient and efffective manintenance planning of maintenace and execution reduces the Total Cost of Ownership of the facility lighting. Reducing stray light, maintenanceTRANSCRIPT
AREALUX AL90 EXAMPLE LIGHT PLAN MH45 MD180
4 x AREALUX AL90 per mast Mast height 45m Mast distance 180m
Egem = 12 lx U0 > 0.6
Contactpersoon: Ordernr.: Firma: Klantnr.:
Date: 19.09.2012Operator: www.AREALUX.nl
AREALUX AL90 EXAMPLE LIGHT PLAN MH45 MD18019.09.2012
Operator www.AREALUX.nlTelephone +31 40 23 77 528
Faxe-Mail [email protected]
Table of contents
AREALUX AL90 EXAMPLE LIGHT PLAN MH45 MD180Project Cover 1Table of contents 2AREALUX AL90 V6.0
Luminaire Data Sheet 3Example light plan
Sport Luminaires (Coordinates List) 4Exterior Surfaces
Calculation area 180 x 180mIsolines (E, Perpendicular) 6
Preliminary Values based on simulation - for reference only - CONFIDENTIAL Page 2
AREALUX AL90 EXAMPLE LIGHT PLAN MH45 MD18019.09.2012
Operator www.AREALUX.nlTelephone +31 40 23 77 528
Faxe-Mail [email protected]
AREALUX AL90 V6.0 / Luminaire Data Sheet
See our luminaire catalog for an image of the luminaire.
Luminous emittance 1:
800
1200
1600
cd/klm 11537%C0 - C180 C90 - C270
0° 15° 30°
45°
60°
75°
90°
105°105°
90°
75°
60°
45°
30° 15° 0°
Luminaire classification according to CIE: 100CIE flux code: 84 96 99 100 101
Due to missing symmetry properties, no UGR table can be displayed for this luminaire.
Preliminary Values based on simulation - for reference only - CONFIDENTIAL Page 3
AREALUX AL90 EXAMPLE LIGHT PLAN MH45 MD18019.09.2012
Operator www.AREALUX.nlTelephone +31 40 23 77 528
Faxe-Mail [email protected]
Example light plan / Sport Luminaires (Coordinates List)
1111 2222
3333 4444
150.00 m-150.00 -90.00 90.00
150.00 m
-150.00
-90.00
90.00
Scale 1 : 2145
List of the Sport Luminaires
Luminaire Index Position [m] Aiming Point [m] Angle [°] Alignment PoleX Y Z X Y Z
AREALUX AL90 V6.0 1 -90.000 -90.000 45.000 -21.762 -158.238 0.000 25.0 (C 0, G 0) /
AREALUX AL90 V6.0 1 -90.000 -90.000 45.000 -21.762 -21.762 0.000 25.0 (C 0, G 0) /
AREALUX AL90 V6.0 1 -90.000 -90.000 45.000 -158.238 -158.238 0.000 25.0 (C 0, G 0) /
AREALUX AL90 V6.0 1 -90.000 -90.000 45.000 -158.238 -21.762 0.000 25.0 (C 0, G 0) /
Preliminary Values based on simulation - for reference only - CONFIDENTIAL Page 4
AREALUX AL90 EXAMPLE LIGHT PLAN MH45 MD18019.09.2012
Operator www.AREALUX.nlTelephone +31 40 23 77 528
Faxe-Mail [email protected]
Example light plan / Sport Luminaires (Coordinates List)
List of the Sport Luminaires
Luminaire Index Position [m] Aiming Point [m] Angle [°] Alignment PoleX Y Z X Y Z
AREALUX AL90 V6.0 2 90.000 -90.000 45.000 21.762 -158.238 0.000 25.0 (C 0, G 0) /
AREALUX AL90 V6.0 2 90.000 -90.000 45.000 21.762 -21.762 0.000 25.0 (C 0, G 0) /
AREALUX AL90 V6.0 2 90.000 -90.000 45.000 158.238 -158.238 0.000 25.0 (C 0, G 0) /
AREALUX AL90 V6.0 2 90.000 -90.000 45.000 158.238 -21.762 0.000 25.0 (C 0, G 0) /
AREALUX AL90 V6.0 3 -90.000 90.000 45.000 -21.762 158.238 0.000 25.0 (C 0, G 0) /
AREALUX AL90 V6.0 3 -90.000 90.000 45.000 -21.762 21.762 0.000 25.0 (C 0, G 0) /
AREALUX AL90 V6.0 3 -90.000 90.000 45.000 -158.238 158.238 0.000 25.0 (C 0, G 0) /
AREALUX AL90 V6.0 3 -90.000 90.000 45.000 -158.238 21.762 0.000 25.0 (C 0, G 0) /
AREALUX AL90 V6.0 4 90.000 90.000 45.000 21.762 158.238 0.000 25.0 (C 0, G 0) /
AREALUX AL90 V6.0 4 90.000 90.000 45.000 21.762 21.762 0.000 25.0 (C 0, G 0) /
AREALUX AL90 V6.0 4 90.000 90.000 45.000 158.238 158.238 0.000 25.0 (C 0, G 0) /
AREALUX AL90 V6.0 4 90.000 90.000 45.000 158.238 21.762 0.000 25.0 (C 0, G 0) /
Preliminary Values based on simulation - for reference only - CONFIDENTIAL Page 5
AREALUX AL90 EXAMPLE LIGHT PLAN MH45 MD18019.09.2012
Operator www.AREALUX.nlTelephone +31 40 23 77 528
Faxe-Mail [email protected]
Example light plan / Calculation area 180 x 180m / Isolines (E, Perpendicular)
1010 10
10
10
10
10
12
1212
12
1212
12
12
12 12
12
12
1212
12
12
12 12
12
12
12
1212
12
12
12
12
12 12
12
12
1212
12
1212
12
12
1212
14
14
1414
14
14
14
14
14
14
90.00 m-90.00
90.00 m
-90.00
Values in Lux, Scale 1 : 1500Position of surface in external scene:Marked point: (-90.000 m, -90.000 m, 0.000 m)
Grid: 25 x 25 Points
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax12 7.42 16 0.64 0.48