att-1_piping class summary (1)
DESCRIPTION
classTRANSCRIPT
![Page 1: ATT-1_Piping Class Summary (1)](https://reader030.vdocuments.net/reader030/viewer/2022020200/55cf9aea550346d033a4010c/html5/thumbnails/1.jpg)
GARRAF FINAL DEVELOPMENT PLAN (GFDP) PROJECT
Document No.: GFDP-COM-51-PP-SP-99-0002
Revision: Rev. B2
Page: 1 OF 1
Pre (BarG) Temp. (°C)
11007GX Lean Amine (AGRU) 150 RF Non-Sour CS 3 A106 Gr. B 17 -5/200 B31.3
11007GY Rich Amine (AGRU) 150 RF Sour CS 3 A106 Gr. B 17 -5/200 B31.3
11085GX Dry Gas (Cold) 150 RF Non-Sour LTCS 1.5 A333 Gr.6 17 -46/100 B31.3
11380GX Rich MEG 150 RF Non-Sour LTCS 3 A333 Gr.6 17 -46/150 B31.3
11412GX Instrument Air / Plant Air / Nitrogen 150 RF Non-Sour CS 1 A106 Gr. B 12 -5/100 B31.3
11412GY
Dry Gas (Hot, LP) / Lean MEG /
Debutanizer / Fuel Gas (LP) / Diesel Oil
/ Hot Oil
150 RF Non-Sour CS 1.5 A106 Gr. B 17 -5/200 B31.3
11432GX Raw Water / Service Water / Fire Water 150 RF Non-Sour CS 3 A106 Gr. B 16.8 -5/100 B31.3
11432GY H2S Free HP Feed (d/s of AGRU) 150 RF Non-Sour CS 3 A106 Gr. B 17 -5/100 B31.3
11440GX
Process Gas / Process Fluid / LP Feed /
High H2S HP Feed / Sour Hydrocarbon
/ LP Flare (Wet) /
150 RF Sour CS 3 A106 Gr. B 17-5/200
(-29 *)B31.3
11440GYClosed Drain / Open Drain / Sour
Process Water150 RF Sour CS 6 A106 Gr. B 17 -5/100 B31.3
11502GX LP Flare (Cold) / Hydrocarbons 150 RF Sour LTCS 3 A333 Gr.6 3.5 -46/200 B31.3
13021GX Rich Amine (AGRU) - Two Phase 150 RF Sour SS 0A312
316/316L17 -5/200 B31.3
13092GX Cold Flare / Cold Blowdown 150 RF Non-Sour SS 0A312
304/304L3.5 -100/120 B31.3
13411GXSour Hydrocarbon with Water / Acid
Flare150 RF Sour SS 0
A312
316/316L17 -5/200 B31.3
13411GY Potable Water / Demineralized Water 150 RF Non-Sour SS 0A312
316/316L10 -5/100 B31.3
13411GZH2S Free HP Feed (d/s of AGRU) with
Water150 RF Non-Sour SS 0
A312
316/316L17 -5/100 B31.3
17000GX Fire Water (Underground Ring Main) 150 RF Non-Sour HDPE 0 (DIN 8074) 12 51 B31.3
18011GXFire Water ( Deluge System/ Water
Spray, Dry)150 RF Non-Sour
CS
(GALV)0
A106 Gr. B
(GALV)16 -5/100 B31.3
18160GX NaClO Injection 150 RF Non-SourCS PTFE-
Lined0 A106 Gr. B 3.5 -5/100 B31.3
31085GXDeethanizer OVHD / Propane Ref
System300 RF Non-Sour LTCS 1.5 A333 Gr.6 26.5 -46 / 110 B31.3
31412GXDry Gas (Hot, MP) / Depropanizer / Fuel
Gas (MP)300 RF Non-Sour CS 1.5 A106 Gr. B 42 -5/125 B31.3
31412GYDry Gas (Hot, MP) / Depropanizer / Fuel
Gas (MP)300 RF Sour CS 3 A106 Gr.B 45.1 -5/150 B31.3
31412GZ Sour Hydrocarbon Liquid with Water 300 RF Sour CS 6 A106 Gr.B 45 -5/63 B31.3
31440GX
Process Liquid / Process Gas / Process
Water 300 RF Sour CS 6 A106 Gr.B 22.5 -5/120 B31.3
33092GX Deethanizer OVHD (after Depress) 300 RF Non-Sour SS 0
A312
304/304L 20 -100/100 B31.3
33411GX
Sour Hydrocarbon Liquid with Water /
Sour Gas / Chemical Injection 300 RF Sour SS 0
A312
316/316L 45 -5/160 B31.3
61412GX Dry Gas (Hot, HP Suction) 600 RF Non-Sour CS 1.5 A106 Gr. B 53 -5/100 B31.3
61440GX Process Liquid / Process Gas 600 RF Sour CS 3 A106 Gr.B 89.7 83 B31.3
61440GY Process Liquid / Process Gas 600 RF Sour CS 6 A106 Gr.B 92 -5/90 B31.3
91412GX Dry Gas (Hot, HP Discharge) 900 RF Non-Sour CS 1.5 A106 Gr. B 98 -5/150 B31.3
151440GX Process Liquid / Process Gas 1500 RF Sour CS 6 A106 Gr.B B31.3
Pipe
* Intermittent (Only during blowdown at -21 ℃ to Flare)
Code
PIPING CLASS SUMMARY TABLE
Design
Fluid Service Basic Mat'lCA
(mm)
ATTACHMENT-1
Piping Class ServiceFlange
RatingFacing