AULA TÉCNICA
30 2006 ARREFECIMENTO
INSTRUTOR: SCOPINOINSTRUTOR: SCOPINO
![Page 2: AULA TÉCNICA 30 2006 ARREFECIMENTO INSTRUTOR: SCOPINO](https://reader034.vdocuments.net/reader034/viewer/2022051400/552fc113497959413d8c6e7d/html5/thumbnails/2.jpg)
SCOPINO TREINAMENTOS
ARREFECIMENTO
AULA: AULA:
TAMPA
![Page 3: AULA TÉCNICA 30 2006 ARREFECIMENTO INSTRUTOR: SCOPINO](https://reader034.vdocuments.net/reader034/viewer/2022051400/552fc113497959413d8c6e7d/html5/thumbnails/3.jpg)
ENVIE SUAS DÚVIDAS À UMEC
TEMOS PLANTÃO DE DÚVIDAS AO VIVO COM O INSTRUTOR
SCOPINO NO FINAL DESTA AULA.
![Page 4: AULA TÉCNICA 30 2006 ARREFECIMENTO INSTRUTOR: SCOPINO](https://reader034.vdocuments.net/reader034/viewer/2022051400/552fc113497959413d8c6e7d/html5/thumbnails/4.jpg)
RECAPITULANDO
NA AULA PASSADA, APRENDEMOS SOBRE O TEMA: RADIADOR 2.
AGORA VEREMOS:
TAMPA
![Page 5: AULA TÉCNICA 30 2006 ARREFECIMENTO INSTRUTOR: SCOPINO](https://reader034.vdocuments.net/reader034/viewer/2022051400/552fc113497959413d8c6e7d/html5/thumbnails/5.jpg)
Fluxo do excesso de calor, durante a dissipação
Motor Trocador ArLíquido de
refrigeração
![Page 6: AULA TÉCNICA 30 2006 ARREFECIMENTO INSTRUTOR: SCOPINO](https://reader034.vdocuments.net/reader034/viewer/2022051400/552fc113497959413d8c6e7d/html5/thumbnails/6.jpg)
DETALHES
O SISTEMA DE ARREFECIMENTO DEVE SER SELADO, PARA SE TER UMA TEMPERATURA MAIS ALTA DO SISTEMA, SEM COMPROMETÊ-LO.
PODEMOS TER A TAMPA DO RADIADOR, OU TAMPA DO RESERVATÓRIO DE EXPANSÃO. AMBAS POSSUEM A MESMA FUNÇÃO.
![Page 7: AULA TÉCNICA 30 2006 ARREFECIMENTO INSTRUTOR: SCOPINO](https://reader034.vdocuments.net/reader034/viewer/2022051400/552fc113497959413d8c6e7d/html5/thumbnails/7.jpg)
TAMPA DO RESERVATÓRIO
![Page 8: AULA TÉCNICA 30 2006 ARREFECIMENTO INSTRUTOR: SCOPINO](https://reader034.vdocuments.net/reader034/viewer/2022051400/552fc113497959413d8c6e7d/html5/thumbnails/8.jpg)
TAMPA DO RADIADOR
![Page 9: AULA TÉCNICA 30 2006 ARREFECIMENTO INSTRUTOR: SCOPINO](https://reader034.vdocuments.net/reader034/viewer/2022051400/552fc113497959413d8c6e7d/html5/thumbnails/9.jpg)
A EVOLUÇÃO
OS MATERIAIS APLICADOS NA TAMPA ERAM DE METAL, MAIS PESADAS E SUJEITAS A CORROSÃO. AS PEÇAS MAIS ATUAIS, SÃO PRATICAMENTE TODAS EM MATERIAL PLÁSTICO.EM SUA FIXAÇÃO NO RADIADOR OU RESERVATÓRIO, PODE SER DE ROSCA OU TRAVAS COM DENTES.O TESTE É COM EQUIPAMENTO ESPECÍFICO.
![Page 10: AULA TÉCNICA 30 2006 ARREFECIMENTO INSTRUTOR: SCOPINO](https://reader034.vdocuments.net/reader034/viewer/2022051400/552fc113497959413d8c6e7d/html5/thumbnails/10.jpg)
AS VÁLVULAS
PRESSÃO
DEPRESSÃO
![Page 11: AULA TÉCNICA 30 2006 ARREFECIMENTO INSTRUTOR: SCOPINO](https://reader034.vdocuments.net/reader034/viewer/2022051400/552fc113497959413d8c6e7d/html5/thumbnails/11.jpg)
VÁLVULA DE PRESSÃO
PERMITE QUE O VAPOR ACUMULADO NO SISTEMA SAIA DO RADIADOR E CHEGUE AO RESERVATÓRIO OU DIRETO PARA A ATMOSFERA.
A PRESSÃO DE TRABALHO PODE SER DE 1,0 - 1,4 bar OU MAIS.
QUANTO MAIS ALTA A PRESSÃO DE TRABALHO MENOS SERÁ A EBULIÇÃO.
![Page 12: AULA TÉCNICA 30 2006 ARREFECIMENTO INSTRUTOR: SCOPINO](https://reader034.vdocuments.net/reader034/viewer/2022051400/552fc113497959413d8c6e7d/html5/thumbnails/12.jpg)
VÁLVULA DE DEPRESSÃO
PERMITE QUE ENTRE AR OU LÍQUIDO PARA RESTABELECER O VOLUME NO SISTEMA APÓS O SEU RESFRIAMENTO.
OU SEJA, NA FASE DE AQUECIMENTO COM A DILATAÇÃO DO LÍQUIDO SAI AR OU LÍQUIDO, QUE DEPOIS DEVE SER REPOSTO NA FASE DE RESFRIAMENTO.
![Page 13: AULA TÉCNICA 30 2006 ARREFECIMENTO INSTRUTOR: SCOPINO](https://reader034.vdocuments.net/reader034/viewer/2022051400/552fc113497959413d8c6e7d/html5/thumbnails/13.jpg)
MAIS DICAS
![Page 14: AULA TÉCNICA 30 2006 ARREFECIMENTO INSTRUTOR: SCOPINO](https://reader034.vdocuments.net/reader034/viewer/2022051400/552fc113497959413d8c6e7d/html5/thumbnails/14.jpg)
PERGUNTA
QUANDO HÁ MANGUEIRAS TOTALMENTE FECHADAS NO
RESFRIAMENTO O DEFEITO ESTÁ NA TAMPA ?
![Page 15: AULA TÉCNICA 30 2006 ARREFECIMENTO INSTRUTOR: SCOPINO](https://reader034.vdocuments.net/reader034/viewer/2022051400/552fc113497959413d8c6e7d/html5/thumbnails/15.jpg)
SCOPINO TREINAMENTOS
RESPOSTA
SIM.O DEFEITO OCORRE PELO
EMPERRAMENTO DA VÁLVULA DE DEPRESSÃO DA TAMPA, QUE NÃO
PERMITE A ENTRADA DE AR OU LÍQUIDO NA FASE DE RESFRIAMENTO,
FAZENDO COM QUE AS MANGUEIRAS SE FECHEM.
![Page 16: AULA TÉCNICA 30 2006 ARREFECIMENTO INSTRUTOR: SCOPINO](https://reader034.vdocuments.net/reader034/viewer/2022051400/552fc113497959413d8c6e7d/html5/thumbnails/16.jpg)
OBRIGADO PELO ACOMPANHAMENTO
DAS AULAS. ATÉ A PRÓXIMA:
ARREFECIMENTO ARREFECIMENTO 3131SANGRIASANGRIA
Instrutor Scopino
![Page 17: AULA TÉCNICA 30 2006 ARREFECIMENTO INSTRUTOR: SCOPINO](https://reader034.vdocuments.net/reader034/viewer/2022051400/552fc113497959413d8c6e7d/html5/thumbnails/17.jpg)
E AGORA VAMOS AO VIVO
AO PLANTÃO DE DÚVIDAS COM O SCOPINO
UMEC – UNIVERSIDADE DO MECÂNICO