basic panels & accessories
TRANSCRIPT
V A R C O P R U D E N B U I L D I N G S
Basic Panels & Accessories
The field guide for correct installation of Varco Pruden’s Wall and Roof Systems, Tuff-Lites, Wallites, Doors, Windows, Gutters and Trim.
This page intentionally left blank.
INDEX
SECTION TOPIC
FASTENERS FASTENER IDENTIFICATION ROOF FASTENERS WALL FASTENERS
SHEETING ROOF MASTIC MASTIC & SHEETING-ROOF FASTENER APPLICATION-ROOF SIDEWALLS ENDWALLS
TUF-LITE TUF-LITE UL90 INSULATION WALK DOOR CANOPY OVERHEAD DOORS LOUVERS VENTILATORS LINER PANELS PURLIN & GIRT CLOSURES
TRIM CORNER CLOSURES STANDARD TRIMS PEAK CAP EAVE GUTTER & DOWNSPOUTS MULTI-GUTTER HARD RUBBER INSIDE CLOSURE PLUG PANEL CLOSURES
C
D
A
ACCESSORIES
INDEX 03/15/14
A1A2A3-A4
B4-B6B7-B14B15B16-B17
C1-C2C3-C4C5-C6C7C8C9-C10C11-C12C13-C16C17
D1D2-D3D4D5-D8 D9-D10D11D12
NOTE: BUILDING PLANS AND SED'S SUPERCEDE INSTALLATION GUIDE.
B1-B2B3
SEE SED'S FOR SPECIFIC PART NUMBERS AND SEALANTS REQUIREMENTS.
FASTENER APPLICATION
#12-14 x 1 14" SELF - DRILLSTRUCTURAL FASTENER W/5
8" O.D. SEALING WASHER
(1 12" OPTIONAL)
14-14 x 7 8" SELF - DRILL
STITCH FASTENERW/ 5 8" O.D. SEALINGWASHER
#12-14 x 1 14" SELF - DRILLSTRUCTURAL FASTENER W/7
8" O.D. SEALING WASHER
(1 12" OPTIONAL)
18" BLIND RIVET
14 - 14 x 1 1/8" SELF - DRILLSTITCH FASTENERW/ 78" O.D. SEALING WASHER
VP-205 RIVET
PANEL TO STRUCTURALCONNECTIONS
TUF-LITE INSTALLATION(UL-60)
PANEL TO PANELCONNECTIONS
PANEL TO STRUCTURALCONNECTIONS
PANEL TO PANELCONNECTIONS
PANEL TO STRUCTURALCONNECTIONS
TRIM TO STRUCTURALS
PANEL TO PANELCONNECTIONS
TRIM TO PANELS
LOUVERS
WALL LITES
BUILDING TRIM, EAVEGUTTER LAPS & CLOSURES
TUF-LITE INSTALLATION(UL-60)
TUF-LITE INSTALLATION(UL-90)
CHECK THE WAREHOUSE SHIPPING LIST FOR THE TYPE AND NUMBER OF FASTENERS SHIPPED.THE ABOVE INFORMATION IS TO BE USED AS AN IDENTIFICATION GUIDE FOR THE PROPERAPPLICATION OF EACH TYPE OF FASTENER.
1.2.
ROOF
ROOF
ROOF
ROOF
WALL
WALL
MISC.
MISC.
FASTENER IDENTIFICATION / APPLICATION GUIDEA-1
03/15/14
#12-14 x 1 14" SELF - DRILLSTRUCTURAL FASTENER W/5
8" O.D. SEALING WASHER
14-14 x 7 8" SELF - DRILL
STITCH FASTENERW/ 5 8" O.D. SEALINGWASHER
GUTTER
TUF-LITE INSTALLATION(UL-90)
#17/12-14 x 1 7/8" SELF -DRILL STRUCTURALSTAND-OFF FASTENER W/ 5 8"O.D. SEALING WASHER
WALL
PANEL TO STRUCTURALCONNECTIONS WITHGREATER THAN 4" BLANKETINSULATION (EXCEPT ATCRIMPED BASE AND ATFRAMED OPENINGS)
58" ROOF
SEALING WASHER
NONWALKING-HIGH
SPEED DRILL POINT
DEEP THREADS DRAWPANELS SECURELY
TOGETHER
LARGE THREAD BODY,SMALL DRILL POINT,EXTRUDES HOLE INPANEL, INCREASINGHOLDING POWER.
1/4-14 X 7 8"SELF-DRILLING
STITCH FASTENER
12-14 X 1 14"(1 12" OPTIONAL)SELF-DRILLINGSTRUCTURAL
FASTENER
TAPE SEALANT
ROOFPANELLAP
PURLINPURLIN BEARING
EDGE
SECTION THROUGH ROOFSHOWING CORRECT
FASTENER APPLICATION
AFTER PRE-DRILLING, METALSHAVINGS MUST BE CLEANED FROM
PANEL SURFACE TO PREVENTCORROSION.
NOTE:
PANEL TOSTRUCTURALAPPLICATION
PANEL TOPANEL
APPLICATION
STANDARD ROOF FASTENERSA-2
03/15/14
SECTION THROUGH WALLSHOWING CORRECTFASTENER APPLICATION
AFTER PRE-DRILLING, METAL SHAVINGSMUST BE CLEANED FROM PANELSURFACE TO PREVENT CORROSION.
NOTE:
STANDARD WALL FASTENERS WITH 4" OR LESS INSULATIONA-3
03/15/14
58" ROOF
SEALING WASHER
NONWALKING-HIGH
SPEED DRILL POINT
DEEP THREADS DRAWPANELS SECURELY
TOGETHER
LARGE THREAD BODY,SMALL DRILL POINT,EXTRUDES HOLE INPANEL, INCREASINGHOLDING POWER.
1/4-14 X 7 8"SELF-DRILLING
STITCH FASTENER
12-14 X 1 14"(1 12" OPTIONAL)SELF-DRILLINGSTRUCTURAL
FASTENER
WALLPANELLAP
GIRT
PANEL TOSTRUCTURALAPPLICATION
PANEL TOPANEL
APPLICATION
PRE-DRILLING ISRECOMMENDED.
SECTION THROUGH WALLSHOWING CORRECTFASTENER APPLICATION
AFTER PRE-DRILLING,METAL SHAVINGS MUSTBE CLEANED FROMPANEL SURFACE TOPREVENT CORROSION.
NOTE:
STANDARD WALL FASTENERS WITH OVER 4" INSULATIONA-4
03/15/14
58" ROOF
SEALING WASHER
NONWALKING-HIGH
SPEED DRILL POINT
DEEP THREADS DRAWPANELS SECURELY
TOGETHER
LARGE THREAD BODY,SMALL DRILL POINT,EXTRUDES HOLE INPANEL, INCREASINGHOLDING POWER.
1/4-14 X 7 8"SELF-DRILLING
STITCH FASTENER
17/12-14 X 1 7/8"SELF-DRILLING
STAND-OFFSTRUCTURAL
FASTENER
WALLPANELLAP
GIRT
PANEL TOSTRUCTURALAPPLICATION
PANEL TOPANEL
APPLICATION
PRE-DRILLING ISRECOMMENDED.
#17 STAND-OFFSHOULDER
58" +/-
NOTE: USE STANDARD 1 14" FASTENERS AT
CRIMPED BASE AND AROUND FRAMEDOPENINGS.
1 2
DIRECTION TO ERECTPANEL RIB ROOF
SIDEWALL ONE
SIDEWALL TWOBUILDING LENGTH
FIELD CUT(IF REQ'D)
END WALLEND WALL
B.L. B.L.ROOF PLAN
A
B
C
FOR BUILDINGS HAVING ROOFEXTENSIONS, CANOPIES, LEAN-TO'S,ETC., WALL SHEETING SHOULD BEINSTALLED BEFORE ROOF SHEETS TOALLOW FOR WORKING CLEARANCES.
IMPORTANT NOTE:
BL
(A) & (C) denote panel rib roof sheets (B) denotes panel rib cap sheet.
Line (1) is location of the lap rib & line (2) represents the purlin bearing rib of panels (A) &(C) and cap sheet (B).
Locate the center of the lap rib exactly over B.L. Attach panels (A) & (C). Then attach capsheet (B).
Each side of the panel rib roof and the panel rib cap must be run in conjuction with eachother to insure correct alignment.
Refer to different sections of this manual for details relating to eave alignment of roof panels,mastic application, fastener types and spacing and building accessories located on the roof.
All damaged paint finishes are to be retouched to prevent rusting.
In the event a screw is installed in the wrong location or should a screw break during thedriving process, remove the screw and install one of a larger diameter to prevent a potentialleak. If removal of a screw remnant is not possible, water proofing measures are to be takento insure water tightness.
NOTES:
1.
2.
3.
4.
5.
6.
7.
PANEL RIB INSTALLATION / ROOF PANELSB-1
03/15/14
Concentrated heavy loads (personnel or materials) occurring on the roof during constructionshall be distributed uniformly over a large area in such a manner as to prevent damage tobuilding components.
All metal shavings occurring as a result of drilling operations on the roof are to be removed insuch a manner as to prevent damage or staining of roof finish.
NOTES:
8.
9.
PANEL RIB INSTALLATION / ROOF PANELSB-2
10/01/09
AS SPECIFIED
2"
OVERHANG
SELF-DRILLINGSTITCHFASTENER
MASTIC
ROOF SHEET
PURLINBEARINGEDGE
MASTICINSTALLEDON "WET"SIDE OF LAP
EAVE MEMBER
ROOF SHEET
EXTEND MASTIC DOWN PURLINBEARING EDGE AND RETURN TOWEB SIDE OF EAVE MEMBER
MASTIC
WETSIDE
LAP RIB DETAIL
REMOVING RELEASE PAPER
ROOF SHEET
PURLINBEARINGEDGE
MASTIC DETAIL AT EAVE PURLIN
SINGLE LAP CONDITION
IMPORTANT: REMOVERELEASE PAPER BYPULLING PAPER BACK ATAPPROXIMATELY 180°.
Clean area where mastic will be applied.
Install mastic on purlin bearing lap rib of roof(prior to installing next roof sheet), applypressure over entire area to obtain adhesion.
END LAP DETAILInstall mastic at end lapedges as shown (all roofsheet end laps)
PURLIN
LOWERROOFSHEET
UPPERROOFSHEET
TAPE MASTIC
4"1
2" 3 12"
INSTALLATION PROCEDURE / TAPE MASTICB-3
03/15/14
FLOW
STEP ONEROOF SHEET END LAP CONDITION
INSTALL MASTIC ON "WET" SIDE OFSIDE-LAP AND EXTEND DOWN 6"OVER PREVIOUSLY INSTALLEDMASTIC.
ROOF PURLIN
PREVIOUSLYINSTALLEDMASTIC.
6" MASTICLAP
A
B
STEP TWO
ROOF SHEET END LAP CONDITION
Position roof sheet "A" lap rib over previously installed roofsheet purlin bearing edge. Use standard lap dimensions.
Start tape mastic approx. 6" up adjacent sheet overlappingpreviously installed mastic.
Install mastic across roof sheet and downpurlin bearing rib as shown.
Install mastic on "WET"side of purlin bearing edgeas shown.
Fasten roof sheet to purlinsother than purlin at end lapcondition. Refer to fastenerdetails for recommendedtypes and placement of rooffasteners.
Remove release paperbefore installing sheet "B".
Position sheet "B" overpreviously installed roofsheets. Used standard roofsheet lap dimensions.
Attach sheet "B" to purlinsper fastening details. Useonly recommended rooffasteners and install insequence as shown.
Install mastic as shown,lapping previously installedmastic approx. 6". Removerelease paper from mastic.
1.
2.
3.
4.
5.
6.
7.
8.
9.
MASTIC & SHEETING INSTALLATION / ROOF B-4
03/15/14
3"
6" LAP
FLOW
3"
PREVIOUSLYINSTALLED ROOFSHEET
TAPEMASTIC
PREVIOUSLYINSTALLEDMASTIC
ROOFPURLIN
A
FLOW
FLOW
C
A
B
D
C
A
B
TAPE MASTIC INSTALLEDON "WET" SIDE OF LAPRIB.
INSTALL MASTICACROSS ROOFSHEET AND DOWNPURLIN BEARINGRIB AS SHOWN.
ROOF PURLIN
PREVIOUSLYINSTALLEDROOF SHEETS
6" LAP
3"
6" MASTIC LAP
PREVIOUSLYINSTALLEDMASTIC
PREVIOUSLYINSTALLEDROOFSHEETS
ROOFPURLIN
NOTE: MASTIC TOBE INSTALLED ON"WET" SIDE OF LAPRIB.
Position roof sheet "C" over previouslyinstalled roof sheets as shown. Maintainstandard lap dimension.
10. Fasten roof sheet to purlins other thanpurlin at end lap condition. Refer tofastener details for recommended fastenertypes and placement .
11.
Apply tape mastic to roof sheet "C"as shown lapping 6" over previouslyinstalled mastic.
12.
Apply tape mastic to roofsheet "D" as shown. Lapmastic over previouslyinstalled mastic, approx. 6".
14.
Mastic and sheet placement forfour-lap condition at end lapsshould now be watertight.Repeat steps 1 thru 4 forremaining roof sheets.
15.
Remove release paper and installsheet "D". Position over previouslyinstalled roof sheets and attach topurlins per fastener details.
13.
STEP THREE
STEP FOURROOF SHEET END LAP CONDITION
NOTE: MAINTAINSTANDARD ROOFSHEET/PURLIN LAPDIM.
MASTIC & SHEETING INSTALLATION / ROOF B-5
03/15/14
ROOF SHEET END LAPCONDITION
3"
1"
MASTIC TO BE INSTALLEDAPPROX. 1" FROM EDGE OFCAP SHEET.
ROOF SHEET
PURLIN
MASTIC
PANEL RIBCAP SHEET
ROOF FASTENERS
SECTION THRU RIDGE
CAP SHEET INSTALLATION
PURLINS
ROOF SHEET
PANEL RIB CAPSHEET
MASTIC
ROOF SHEET (REFER TO FASTENERRECOMMENDATIONS)
NOTE: CAP SHEET TO BE USED ASAN ALIGNMENT GUIDE WHENSTARTING SHEETING ON OPPOSITESIDE OF RIDGE.
INSTALLATION PROCEDURES / CAP SHEETB-6
10/01/09
FASTENER APPLICATION ON ROOFVP "STANDARD" ROOF CONSTRUCTION
(QUALIFIES AS UL CLASS 60 UPLIFT RATED ROOF)
ROOF STITCHFASTENER
1'-0" 1'-0" 1'-0"
STRUCTURALFASTENER
END LAP & RIDGE CAP
INTERMEDIATE PURLIN
BUILDING EAVE
STITCH FASTENER
STRUCTURALFASTENER
STRUCTURALFASTENER
PANEL SIDELAP
FASTENER SPACING AT ROOF PANELSSECTION THRU ROOF
STITCH FASTENER
STITCH FASTENER
FASTENER APPLCATION ON ROOF B-7
10/01/09
FASTENER APPLICATION ON ROOF B-8
03/15/14
CENTERLINE EAVEMEMBER FLANGE &ROOF STRUCTURALFASTENERS.
CENTERLINE PURLINFLANGE & ROOFSTRUCTURALFASTENERS.
NOTE: INSTALL ROOFSTRUCTURALFASTENERS FIRST. (INSEQUENCE ASSHOWN).
CENTERLINE ROOFSTRUCTURALFASTENERS.
CENTERLINE PURLINFLANGE & ROOFSTITCH FASTENERS.
TYPICAL AT INTERMEDIATE PURLINS
1 1/
2"
1
A 1
PURLIN
EAVEMEMBER
A
1
6 5 432
TYPICAL AT INTERMEDIATE PURLINS
C
STITCH FASTENER(TYPICAL)
1
C2 3
TYPICAL AT RIDGE CAP & ROOF SHEET END LAPS
1 1/
2"
PURLIN
A
1"
NOTE: INSTALL ROOFSTITCH FASTENERS ATMID-POINTS BETWEENEACH INTERMEDIATEPURLIN.
4" PANEL LAP
3"435261
1
C
2"
B D
NOTE: INSTALLROOF STITCHFASTENER AFTERALL ROOFSTRUCTURALFASTENERS HAVEBEEN INSTALLED(IN SEQUENCE ASSHOWN).
FASTENER APPLICATION ON ROOF"ICE DAMMING"
STRUCTURALFASTENER
END LAP & RIDGE CAP
INTERMEDIATE PURLIN
BUILDING EAVE
STITCH FASTENER
STRUCTURALFASTENER
STRUCTURALFASTENER
PANEL SIDE LAP
FASTENER SPACING AT ROOF PANELS
SECTION THRU ROOF
STITCH FASTENER
STITCH FASTENER
20"
5'-0"5'-0"
1'-0"1'-0" 1'-0"
TYPICAL PURLIN SPACING
ROOF STITCHFASTENER
SIDE LAP FASTENER LOCATIONS:6" O.C. FOR FIRST 10'-0" THEN ATEACH PURLIN AND AT 20" CENTERSTO RIDGE.
FASTENER APPLICATION ON ROOFB-9
10/01/09
2"
4" PANEL LAP
1"
3"
41 8 2 6 3 4
A
B
C
D
1 1/
2"
CENTERLINE ROOFSTRUCTURALFASTENERS.
PURLIN
TYPICAL AT RIDGE CAP & ROOF SHEET END LAPS
NOTE: INSTALL ROOFSTRUCTURAL FASTENERSFIRST. (IN SEQUENCE ASSHOWN).
NOTE: INSTALLROOF STITCHFASTENER AFTERALL ROOFSTRUCTURALFASTENERS HAVEBEEN INSTALLED(IN SEQUENCE ASSHOWN).
NOTE: INSTALL (2) ROOFSTITCH FASTENERS (AT 20"O.C.) BETWEEN EACHINTERMEDIATE PURLIN.
11 2 3
A
1 2 3
A468
TYPICAL AT INTERMEDIATE PURLINS
2
PURLIN
CENTERLINEPURLIN FLANGE &ROOF STRUCTURALFASTENERS.
CENTERLINE PURLINFLANGE & ROOFSTITCH FASTENERS.
1 1/
2"
CENTERLINE EAVEMEMBER FLANGE &ROOF STRUCTURALFASTENERS.
STITCH FASTENER(TYPICAL)
EAVEMEMBER
C
C
1
6"9 7 5
1
3
2
5 7
869 7 5
1 1/
2"
3"5 1/
2"
TYPICAL AT EAVE MEMBER
FASTENER APPICATION ON ROOF B-10
03/15/14
FASTENER APPLICATION ON ROOF"UL CLASS 90-UPLIFT RATED"
STRUCTURALFASTENER
END LAP & RIDGE CAP
INTERMEDIATE PURLIN
BUILDING EAVE
STITCHFASTENER
STRUCTURALFASTENER
STRUCTURALFASTENER
PANELSIDE LAP
FASTENER SPACING AT ROOF PANELS
SECTION THRU ROOF
STITCH FASTENER
STITCH FASTENER
20"
5'-0"5'-0"
1'-0"1'-0" 1'-0"
TYPICAL PURLIN SPACING
ROOF STITCHFASTENER
SIDE LAP FASTENER LOCATIONS:AT EACH PURLIN AND ATMID-POINTS BETWEEN PURLINS.
FASTENER APPLICATION ON ROOF B-11
10/01/09
2"
4" PANEL LAP
1"
3"
11 8 2 6 3 4
A
B
C
D
1 1/
2"
CENTERLINEROOFSTRUCTURALFASTENERS.
TYPICAL AT RIDGE CAP & ROOF SHEET END LAPS
NOTE: INSTALL ROOFSTRUCTURAL FASTENERSFIRST. (IN SEQUENCE ASSHOWN).
NOTE: INSTALLROOF STITCHFASTENER AFTERALL ROOFSTRUCTURALFASTENERS HAVEBEEN INSTALLED(IN SEQUENCE ASSHOWN).
NOTE: INSTALL ROOF STITCHFASTENERS AT MID-POINTSBETWEEN EACHINTERMEDIATE PURLIN.
11 2 3
A
1 2 3
A468
TYPICAL AT INTERMEDIATE PURLINS
1
PURLIN
CENTERLINEPURLIN FLANGE &ROOF STRUCTURALFASTENERS.
CENTERLINEPURLIN FLANGE& ROOF STITCHFASTENERS.
1 1/
2"
CENTERLINE EAVEMEMBER FLANGE &ROOF STRUCTURALFASTENERS.
EAVEMEMBER
C
C9 7 5
2 3 5
649 7 53"
5 46
STITCHFASTENER
TYPICAL AT EAVE MEMBERB-12
03/15/14
FASTENER APPLICATION ON ROOF"UL CLASS 90-UPLIFT RATED & ICE DAMMING"
STRUCTURALFASTENER
END LAP & RIDGE CAP
INTERMEDIATE PURLIN
BUILDING EAVE
STITCH FASTENER
STRUCTURALFASTENER
STRUCTURALFASTENER
PANEL SIDE LAP
FASTENER SPACING AT ROOF PANELS
SECTION THRU ROOF
STITCH FASTENER
STITCH FASTENER
20"
5'-0"5'-0"
1'-0"1'-0" 1'-0"
TYPICAL PURLIN SPACING
ROOF STITCHFASTENER
SIDE LAP FASTENER LOCATIONS:6" O.C. FOR FIRST 10'-0" THEN ATEACH PURLIN AND AT 20" CENTERSTO RIDGE.
FASTENER APPLICATION ON ROOF B-13
10/01/09
2"
4" PANEL LAP
1"
3"
41 8 2 6 3 4
A
B
C
D
1 1/
2"
CENTERLINE ROOFSTRUCTURALFASTENERS.
PURLIN
TYPICAL AT RIDGE CAP & ROOF SHEET END LAPS
NOTE: INSTALL ROOFSTRUCTURAL FASTENERSFIRST. (IN SEQUENCE ASSHOWN).
NOTE: INSTALLROOF STITCHFASTENER AFTERALL ROOFSTRUCTURALFASTENERS HAVEBEEN INSTALLED (INSEQUENCE ASSHOWN).
NOTE: INSTALL (2) ROOF STITCHFASTENERS AT (AT 20" O.C.)BETWEEN EACH INTERMEDIATEPURLIN.
11 2 3
A
1 2 3
A468
TYPICAL AT INTERMEDIATE PURLINS
TYPICAL AT EAVE MEMBER
2
PURLIN
CENTERLINEPURLIN FLANGE &ROOF STRUCTURALFASTENERS.
CENTERLINEPURLIN FLANGE& ROOF STITCHFASTENERS.
1 1/
2"
CENTERLINE EAVEMEMBER FLANGE &ROOF STRUCTURALFASTENERS.
EAVEMEMBER
C
C9 7 5
3 5 7
869 7 53 "
5 46
1
6"
1
2
5 1/
2"
STITCH FASTENER(TYPICAL)
1 1/
2"
FASTENER APPLICATION ON ROOFB-14
03/15/14
DIRECTION OF ERECTION
WALLSTITCHFASTENER
CAPILLARYBEAD
GIRT
SIDE LAP DETAIL
ROOF SHEETING
EAVE OR RAKE MEMBER.(EAVE STRUT MEMBERSHOWN)
GIRTS
WALL STRUCTURALFASTENER, 1 PER FOOTAT INT. GIRTS.
BASE MEMBER
WALL STITCH FASTENER, 1PER SUPPORT AND 1 PERGIRT SPACE, 2 FASTENERSREQUIRED WHEN SPACEEXCEEDS 6'-0".
WALL STRUCTURALFASTENER, 2 PERFOOT.
TEMPORARYBLOCKING MATERIAL(NBVP)
WALL STRUCTURALFASTENER, 2 PERFOOT.
PANEL SIDE LAP
SIDE WALL ELEVATION
Block girts to "LEVEL POSITION"before starting panel erection.Maintain blocking until panel tostructural fasteners are installed.
Align and plumb first wall panel withthe roof panel (making sure notchedtop of side wall panel fits ribs of firstroof panel).
Attach panel to secondary framing(see recommendations for fastenertype and spacing).
Proceed to install adjacent panel. Useonly a minimum number of fastenersto hold panels in place until chalklines can be popped, to assure astraight line run of fasteners.
Install side lap fasteners only after allstructural fasteners are in place.
NOTES:1.
2.
3.
4.
5.
PANEL RIB INSTALLATION / SIDE WALL PANELSB-15
03/15/14
NOTE: FOR INSULATION GREATERTHAN 4", USE #17/12-14 X 1 7
8"STAND-OFF STRUCTURAL FASTENERS.ALWAYS USE 12-14 X 1 1
4" AT CRIMPEDBASE AND AT FRAMED OPENINGS.
ELEVATION
NOTE:1.
2.
3.
4.
Endwall panel marked "A" will be installed first, make sure panel isplumb and that the center of the panel rib is located at the exactcenter of the building ridge .
Attach panel "A". Do not fasten along the left hand edge of panel.The rib of all remaining panels to the left of panel "A" must beunderlapped.
Field cut panels at building line if required or back lap if acceptable.
As roof pitch increases, protective measures are to be taken toprevent personnel or materials from falling from building and resultingin bodily injury.
BL BL
CENTER LINEBUILDING AND PANEL RIB
TOP OF RAKE
FIELDCUT
FIELD CUTIF REQ'D.
BUILDING WIDTH
A
DIRECTION OF ERECTION(UNDER LAP PANEL RIB)
DIRECTION OF ERECTION(STANDARD LAP PROCEDURE)
PANEL RIB "LEFT TO RIGHT" INSTALLATION / ENDWALLSB-16
03/15/14
ELEVATION
NOTE:1.
2.
3.
4.
Endwall panel marked "A" will be installed first. Make sure panel isplumb and that the center of the panel rib is located at the exactcenter of the building ridge.
Attach panel "A". Do not fasten along the right hand edge of panel.The panel rib of all remaining panels to the right of panel "A" MUSTBE UNDERLAPPED.
Field cut panels at building line if required or back lap if acceptable.
As roof pitch increases, protective measures are to be taken toprevent personnel or materials from falling from building and resultingin body injury.
BL BL
TOP OF RAKE
FIELDCUT
FIELD CUTIF REQ'D.
BUILDING WIDTH
A
DIRECTION OF ERECTION(UNDER LAP PANEL RIB)DIRECTION OF ERECTION
(STANDARD LAP PROCEDURE)
CENTER LINEBUILDING AND PANEL RIB
PANEL RIB "RIGHT TO LEFT" INSTALLATION / ENDWALLSB-17
03/15/14
5
4
321
INSTALL TUF-LITE IN ROOFSHEETS IN SEQUENCE ASSHOWN.
PANEL RIBROOFSHEET
INSTALLATION SEQUENCE
DO NOT STEP, WALK ORPLACE HEAVY LOADS ONTUF-LITE PANELS.
IMPORTANT NOTE:
TUF-LITES SHALL BE INSTALLED AS ROOF IS SHEETED ANDPROTECTIVE MEASURES TAKEN TO INSURE AGAINST MATERIALSOR PERSONNEL FROM FALLING THROUGH TUF-LITE.
IMPORTANT:
SIDE LAP DETAIL
END LAP DETAIL
ROOF STITCH FASTENER ATEACH MAJOR RIB.
ROOF STRUCTURAL FASTENERAT MINOR RIB AS SHOWN(TYP. BOTH END LAPS)
TUF-LITE
ROOF SHEET
MASTIC:DOUBLE ROWREQUIRED AT LOWEREND LAP ONLY.SINGLE ROW ATUPPER END LAP. MASTIC
TUF-LITEROOF SHEET
ROOF STITCH FASTENERAT 20" O.C.
ROOF STRUCTURALFASTENER ATSTANDARD SPACINGAT INTERMEDIATEPURLINS
PANEL RIB TUF-LITESTANDARD INSTALLATION
ROOF STITCH FASTENER ATEACH MAJOR RIB.
ROOF STRUCTURAL FASTENERAT MINOR RIBS AS SHOWN(TYP. BOTH END LAPS).
PANEL RIB TUF-LITE STANDARD INSTALLATIONC-1
03/15/14
PANEL RIB TUF-LITE STANDARD INSTALLATIONC-2
10/01/09
SECTION THROUGH TUF-LITE
TUF-LITE SIDE LAP DETAIL
PURLIN SPACE
PURLIN SPACE
1"
1"
1" 3"
3"1"
OPTIONALCONDENSATION PAN
INSULATION
ROOFSHEET
MASTIC
ROOF STITCHFASTENERS@20" O.C.MASTIC
ROOFSHEET
INSULATION TUF-LITETRIM
ROOF STITCHFASTENERS@20" O.C.
TUF-LITE END LAPDIMENSION TO BE THE SAMEAS STANDARD ROOF SHEETEND LAP DIMENSIONS (4")(TYP. BOTH ENDS).
USE INSULATION OR INSIDECLOSURE AS ISOLATIONSPACER.
OPTIONALCONDENSATIONPAN
MASTIC
ROOF SHEET
ROOF STRUCTURALFASTENERS 3 PER FOOT
INSTALL ROOF STRUCTURAL ATSTANDARD SPACING ATINTERMEDIATE PURLINS.
ROOF STRUCTURALFASTENERS 3 PERFOOT
PURLIN
ROOFSHEET
TUF-LITETRIM
5
4
321
INSTALL TUF-LITE IN ROOF SHEETSIN SEQUENCE AS SHOWN.
PANEL RIBROOF SHEET
INSTALLATION SEQUENCE
DO NOT STEP, WALK, ORPLACE HEAVY LOADS ONTUF-LITE PANELS.
IMPORTANT NOTE:
TUF-LITES SHALL BE INSTALLED AS ROOF IS SHEETED ANDPROTECTIVE MEASURES TAKEN TO INSURE AGAINST MATERIALSOR PERSONNEL FROM FALLING THROUGH TUF-LITE.
IMPORTANT:
SIDE LAP DETAIL
END LAP DETAIL
14"-14 X 1 18"
ROOF STITCH FASTENERw/ 7 8" WASHER AT EACHMAJOR RIB.
ROOF STRUCTURAL FASTENER W/ 78"
WASHER AT MINOR RIB AS SHOWN (TYP.BOTH END LAPS)
TUF-LITE
ROOFSHEET
MASTIC:DOUBLE ROWREQUIRED ATLOWER END LAPONLY. SINGLE ROWAT UPPER END LAP. MASTIC
TUF-LITEROOF SHEET
14"-14 X 1 18"ROOF
STITCH FASTENER W/ 78"
WASHER AT 10" O.C.
ROOF STRUCTURALFASTENER W/ 7
8"WASHER AT STANDARDSPACING ATINTERMEDIATE PURLINS.
PANEL RIB TUF-LITE INSTALLATIONU.L. CLASS 90 UPLIFT
ROOF STITCH FASTENER AT EACHMAJOR RIB.
ROOF STRUCTURAL FASTENERAT MINOR RIBS AS SHOWN(TYP. BOTH END LAPS).
PANEL RIB TUF-LITE INSTALLATION U.L. CLASS 90 UPLIFTC-3
03/15/14
SECTION THROUGH TUF-LITE
TUF-LITE SIDE LAP DETAIL
PURLIN SPACE
PURLIN SPACE
1"
1"
1" 3"
3"1"
OPTIONALCONDENSATION PAN
INSULATION
ROOFSHEET
MASTICMASTIC
ROOFSHEET
INSULATIONTUF-LITE TRIM
14"-14 X 1 18"
ROOF STITCHFASTENERS W/ 7
8"WASHERS @ 20" O.C.
TUF-LITE END LAP DIMENSION TO BETHE SAME AS STANDARD ROOF SHEETEND LAP DIMENSIONS (4") (TYP. BOTHENDS).
USE INSULATION ORINSIDE CLOSURE ASISOLATION SPACER.
OPTIONAL CONDENSATIONPAN
MASTIC
ROOF SHEET
ROOF STRUCTURALFASTENERS 3 PER FOOTROOF STRUCTURAL
FASTENERS 3 PERFOOT
PURLIN
ROOFSHEET
TUF-LITETRIM
14"-14 X 1 18"
ROOF STITCHFASTENERS W/ 7
8"WASHERS @ 20" O.C.
ROOF STRUCTURALFASTENERS 3 PER FOOT
PANEL RIB TUF-LITE INSTALLATION U.L. CLASS 90 UPLIFTC-4
03/15/14
WALL BASE DETAIL
A
B
A
A
D
A
C
BASE ANGLE
ATTACH TOBASE ANGLE
INSULATION
FLOORELEVATION
FOLD INSULATIONFACING BACK TOPREVENT "WICKING"ACTION OF EXPOSEDINSULATION.
INSULATION SIDE LAP DETAIL(OPTIONAL)
6"TAB
INSULATION SIDE TAB DETAIL(ROOF AND WALL APPLICATIONS)
DOUBLEFOLDTABS
3" TABEACH SIDE
INSULATION FACING
STARTING ROOF INSULATION
BUILDING LINE
RAKE ANGLEEND WALLINSULATION
DOUBLEFOLDTABS
INSTALLATIONDIRECTION
INSULATIONFACING
ROOFINSULATIONSTARTERSTRIP
INSULATION METHOD #1
INSULATION METHOD #2
NARROW BUILDING
WIDE BUILDING
ATTACH (D) TO PURLIN,LAP (C) OVER (D) ANDGLUE, MAKE SURE (D)DOES NOT EXTEND PASTTOP FLANGE OF PURLIN.
STAPLE 18" O.C.MAXIMUM
BUILDING ACCESSORIES / INSULATIONC-5
03/15/14
CD
ROOFINSULATION
EAVE STRUT
EAVE DETAIL
INSULATION LAP DETAILPURLIN
ROOFINSULATION
ATTACH (D) TO PURLIN,LAP (C) OVER (D) ANDGLUE, MAKE SURE (D)DOES NOT EXTEND PASTTOP FLANGE OF PURLIN.
Wall insulation (A) is shipped in maximum roll lengths and is to be field cut to exactlengths before installing. Wall insulation should extend from top of eave member to 1"below floor elevation. Do not cut long and trim at bottom of wall panels. Glue at eavemember and base angle, pull facing tight and hold in place until wall panel is attached(See Wall Base Detail).
Roof insulation (B) is shipped as one roll for each length or for two or more lengths to befield cut from a single roll, depending on building width. Pull insulation simultaneouslyfrom each side of the building until facing is snug. Allow insulation to expand to it's fullthickness. Fold insulation facing back to prevent " WICKING" action of exposedinsulation, similar to wall base detail. Glue to top of eave member and trim excessinsulation.
Roof insulation (C) and (D) are shipped as one roll for each length. Install in a similarmanner to insulation (B). Use same procedure for end walls as for side walls.
FOLD INSULATIONFACING BACK TOPREVENT"WICKING" ACTIONOF EXPOSEDINSULATION.
GENERAL NOTES:
1.
2.
3.
BUILDING ACCESSORIES / INSULATIONC-6
03/15/14
SECTION @ CANOPYASSEMBLY
Mount attaching angle at 7'-6"above floor. Locate over doorand attach w/ (2) BOLTS-1
2" X3" AND (3) NUTS as shown.
Locate wall structural anglesbetween girts. Field drill 9
16"hole top and bottom into girtsand bolt into place.
Drill (2) holes through wallsheet at 29" - 34" above top ofcanopy as shown and installhangar rods w/ (2) NUTS.
Bolt canopy to attaching angleand hangar rods as shown.
STEP 4
STEP 3
STEP 2
STEP 1
3070 DOORCANOPY
6070 DOORCANOPY
ATTACHINGANGLE
CANOPY
2'-0" 2'-0"
HANGARRODS
CANOPY
ATTACHINGANGLE
HANGARRODS
1'-3" 1'-3"
C.L.DOOR
C.L.DOOR
WALLSHEETING
HEADTRIM
DOORFRAME
12" X 3" BOLT
W/ (3) NUTS
DRILL FASCIA AND ATTACH SCOUP TO DRAINAWAY FROM DOOR OPENING.
NOTE:
7'-6
"
7'-6
"PREASSEMBLEDCANOPY
DOORFRAMEASSEMBLY
ADJUSTINGNUT ANDWASHERS
HANGAR ROD
APPLY SILICONE SEALANTWHERE ROD PENETRATESWALL SHEETING
GIRT
7'-6
"G
IRT
SPAC
ING
29"
TO1
2" X 11/2" A325BOLT ANDNUT (TYP.)
WALLSHEETING
WALLSTRUCTURALANGLES
34"
SERVICE DOOR CANOPY INSTALLATIONC-7
03/15/14
34"
SECTION "F"
BL
DETAIL "A"
DETAIL "C"
DETAIL "D"
DETAIL "E"
SECTION "B"
AT MINOR RIB AT MAJOR RIB
HEADERTRIM
WALLPANEL
DOORFLASHING
WALLSTRUCTURALFASTENER
HEADER
DOORFLASHING JAMB
WALLPANEL
JAMB TRIM(FIELDBEND)
WALLSTRUCTURALFASTENER
WALLSTRUCTURALFASTENER
JAMB TRIM
WALLSTRUCTURALFASTENER
DOORFLASHING
JAMBWALL PANEL
GIRT
"A"
HEADER
JAMB
BASEMEMBER
"B"
"F"
"E"
"D"
GIRT "C"SINGLE JAMB
CEE GIRT SIMILARZEE GIRT SHOWN
GIRT CLIP
(2) 1/2" A307 THINHEAD BOLT & NUT
6"MAX
CONCRETE FSNRAT 24" O.C.
(BY BUILDER)BASE MEMBER
JAMB BASECLIP
1/2" ANCHORRODS WTH
JAMB, SINGLEOR DOUBLE
HARDENED WASHER
(2) 1/2" A307 THINHEAD BOLT & NUT
DOOR HEADER
SINGLE JAMB
HEADER TO JAMB CLIP
(2) 1/2" A307 THINHEAD BOLT & NUT
JAMB,SINGLE ORDOUBLE
ZEE GIRT
(2) 1/2" A307 THINHEAD BOLT & NUT
(JAMB SUPPORTGIRT)
BL
ACCESSORIES / OVERHEAD DOOR OPENINGC-8
03/15/14
MULLIONRIGHTJAMB
LEFTJAMB
SILL ATBASE ANGLE
HEAD & SILLAT GIRT
HEAD & SILL AT STACK
3030 FIXED LOUVERAND
SECTION ATLOUVER
GENERAL PROCEDURES
INSECTSCREEN
3'-0"LOUVER DIM.
3'-0
"LO
UVE
R D
IM.
VP-205 RIVET(TYP.)
JAMB FINSET IN SEALANT
SILLOUTSIDECLOSURE
HEAD GUTTER TROUGH SETIN SEALANT
CUT
SHEE
T O
PEN
ING
=LO
UVE
R D
IM.
VP-205 RIVETS(TYP.)
PANEL RIB
OUTSIDECLOSURE
2 12"
4 12"
12"
1 12"
LOU
VER
DIM
.LO
UVE
R D
IM.
LOU
VER
DIM
.
LOUVER DIM.LOUVER DIM.
PANEL RIB
VP-205RIVET(TYP.)
SHEETMODULE
SHEETMODULE
SHEETMODULE
SHEETMODULELOUVER DIM. MINUS 2 38"
CUT SHEET OPENING=
WINDOW SUPPORTCHANNEL
1 316"1 316"
Installation procedures shown are for louversinstalled on the 3'-0" panel rib module.
1.
Mulling of louvers requires the use of awindow support channel at each mullion.
Stacking of louvers requires the relocation ofscreen clips where the sill overlaps the headgutter.
2.
3.
3030 OPERABLE LOUVER
BUILDING ACCESSORIES / VP LOUVERSC-9
03/15/14
DIRECTION OF
INSTALLATION
SCREENDETAIL
ASSEMBLED VIEW
CUT-OUT VIEW
INSECT SCREENFRAME
VP-205RIVET
ATTACH SCREEN W/CLIPS INTOPRE-LOCATED HOLES
RELOCATESCREEN CLIPAT STACKEDLOUVERS
VP-205 RIVET
STACKEDHEAD &SILL
INSECTSCREEN
STANDARD WALLFASTENERS EACHSIDE OF RIB OVERLOUVER
STANDARDWALL FASTENERARRANGEMENT
ATTACHLOUVER WITH(6) VP-205RIVETS
PANELRIB
3
2
4
1
1
2
3
4
SHEET 2UNDERLAPSSHEET 1
PANELRIB
LOUVER DIM.MINUS 2 38"
LOU
VER
DIM
.SHEET 3OVERLAPSSHEET 2
Install wall sheet 1 in sequence shown. Installinsulation as noted in general procedures ifrequired.
Install sheet 2 by underlapping sheet 1.
Install sheet 3 in the normal manner.
Cut opening in insulation.
Install louver over sheet 3 with jamb fins placedto ovelap ribs of adjacent sheets 1 & 3. (DONOT UNDERLAP LOUVER JAMBS.) SetJambs in sealant.
Install sheet 4 above louver. Lap sheet 4 overjamb fins at louver head and into bottom ofhead gutter trough. Sheet 4 to be installed withlap ribs overlapping the side ribs of sheets 1and 3. Set head in sealant.
Attach louver with (6) VP-205 Rivets. (2) Rivetseach jamb and 2 Rivets at sill. Completeattachment of wall sheets to girts and side lapswith standard wall fasteners.
Attach insect screen to outside of louver usingclips provided. Locate dogging clip for operablelouver as require and fasten with standard wallfasteners.
STEP 1
STEP 2
STEP 3
STEP 4
STEP 5
STEP 6
STEP 7
STEP 8
INSTALLATION PROCEDURE / VP LOUVERC-10
03/15/14
SECTION
APEX 20 VENTILATOR
PANEL RIBROOFPANEL
POP RIVETVENTILATOR TOSLEEVE
WINDBAND
DAMPERCAP
SCREEN
AIRSHAFT
PURLIN
1" DIA. PULLEY
DAMPERCHORD
TAPE MASTIC BOTHSIDES OF CLOSURE
ROOF STRUCTURALFASTENER (3) PERFOOT AT ENDLAPS
NOTE: DETAILED INSTALLATION INSTRUCTIONS AREPACKAGED WITH EACH VENTILATOR.
ROOFSTITCH FSNR 6" O.C.
OUTSIDE CLOSURE(80140) WITHTAPE MASTICBOTH SIDES OF
ROOF STITCH FSNR1 PER HIGH RIB
TAPE MASTIC
INSULATIONRETAINER
PANEL RIBAPEX 20VENT BASE
20" DIA. VENT
CLOSURE
ONLY CUT THE HOLE IN THERIDGE PANEL LARGE ENOUGHTO ALLOW FOR THE FLANGEON THE UNDERSIDE OF THE VENT BASE
BUILDING ACCESSORIES / APEX 20 VENTILATORC-11
03/15/14
REFER TO SED'S FOR MASTICAND FASTENER TYPE.
SECTION
10'-0" RIDGE VENTILATOR
DIRECTION OF ERECTION
ROOF STITCHFASTENER AT EACHMAJOR RIB
CUT AT THIS SIDEOF MAJOR RIB
Locate vent so that the end sectionof vent is resting on the purlinbearing edge of panel rib cap.
Field cut panel rib cap to make a 2'-0"wide cap, center to center of ribs, andleaving a purlin bearing rib at eachside .
1.
2.
By deleting end panels at connection,10'-0" sections of ventilators may bejoined together to make a continuousrun. A continuous run should neverstart or end at building line.
3.
PANEL RIBRIDGE VENT DAMPER
TAPE MASTIC BOTHSIDES OF CLOSURE
ROOF STITCHFASTENER(12" O.C.)
OUTSIDE CLOSURE REFER TO SED'sPROVIDED WITHJOB DRAWINGS.
ACCESSORIES / 10'-0" RIDGE VENTILATORC-12
03/15/14
BL
BASEGIRT
PARTIAL HEIGHTLINER
INSTALLATION DETAILS / PARTIAL AND FULL HEIGHT LINERC-13
03/15/14
FULL HEIGHT LINER@ SIDEWALL
EAVESTRUT
FULL HEIGHTLINER @ RAKE
Liner attaches to face of girts w/wallstructural fasteners at 12" o.c.Field cut liner panel, if required, tofollow slope of rake beam.
NOTES:1.
2.
TRIM ANGLE(ATTACH W/ S.D.FASTENERS 12" O.C.)
RAKEBEAM
ALL LINER @ BASE
GIRT
GIRT
CAP TRIM -ATTACH WITHSTITCH SCREWS12" O.C.
CAP TRIM -ATTACH WITHSTITCH SCREWS12" O.C.
CAP TRIM -ATTACH WITHSTITCHSCREWS @ 12"O.C.
DETAIL ATJAMB
BL
BL
DETAIL ATHEADER
LINER DETAILAT WINDOW
DETAIL AT SILL
LINER
FLOORLINE
BASEGIRT
WINDOWLOCATION
"C"
WALL STITCH.FASTENER
LINER PANEL
SILL
SILL FLASHING
WALLPANEL
WINDOW
WALL PANEL
JAMB
LINER PANELJAMB TRIM
WALL STRUCT.FASTENER
JAMBFLASHING
WINDOW
HEADFLASHING
HEADER
JAMB
WINDOW
LINERPANELGIRT
WALLPANEL
WINDOW OPENING SIZESLiner attaches to face of girts w/wallstructural fasteners @ 12" o.c.
NOTES:1.
2060 72" 12" 21 1/4"
3030
3040
6030
6040
36"
48"
36"
48"
48"
36"
48"
36"
33 1/4"
33 1/4"
69 1/4"
69 1/4"
WINDOW SIZE
DIM."A"
DIM."B"
DIM."C"
DIM. A & C ARE INSIDE CLEARFRAMING DIMENSIONS. (DIM. B ISFROM FLOOR LINE TO TOP OF SILL).
*
"A"
"B"
WALLSTITCHFASTENER
INSTALLATION DETAILS C-14
03/15/14
DETAIL AT HEADER
BL
BL
DETAIL AT JAMB
LINER ATOVERHEAD DOOR
DOORFLASHING
JAMBTRIM
LINERPANEL
DOORJAMB
JAMBTRIM
WALLPANEL
DOORHEADER
DOORFLASHING
LINER HEAD TRIM
LINERPANEL
WALLPANEL
HEADTRIM
WALLSTRUCT.FASTENER12" O.C.
DOORFLASHING
HEAD TRIM
WALLPANEL
LINERPANEL
WALL STRUCT.FASTENER 12" O.C.
LINER HEAD TRIM
WALL STRUCT.FASTENERDOOR
HEADER
DOOR FLASHING
Liner attaches to inside faceof girts w/wall structuralfasteners.
All overhead door flashing &trim attaches to framingw/wall structural fasteners12" O.C.
1.
2.
NOTES:
OVERHEAD DOOR DETAILS / LINER PANELC-15
03/15/14
JAMB TRIM
SERVICE DOORFULL HEIGHT LINER
BL
7'-6"GIRT
BL
BL
BL
7'-6"GIRT
DETAIL AT JAMB
SERVICE DOORPARTIAL HEIGHT LINER
DETAIL AT HEADER
DETAIL AT JAMB
DETAIL AT HEADER
7'-6"GIRT
7'-6"GIRT
DOORFRAME
LINERPANEL
FLOORLINE
DOORFRAME
LINERPANEL
FLOORLINE
LINERPANEL
WALL STITCHFASTENER
DOOR LINERTRIM
WALL STRUCT.FASTENER
DOORFRAME
HEADTRIM
WALLPANEL
WALLPANEL
DOORFRAME
WALLSTRUCT.FASTENERS
DOOR LINERTRIM
LINERPANEL
LINERANGLE
LINERANGLE
WALL PANEL
LINERPANEL
DOOR LINERTRIM
DOORFRAME
WALLSTRUCT.FASTENERS
DOORFRAME
WALLPANEL
HEADTRIM
WALL STRUCT.FASTENER
DOOR LINERTRIM
WALL STITCHFASTENER
LINERPANEL
LINER TRIM
LINER DETAILS AT WALK DOORSC-16
03/15/14
CLOSURE DETAIL @ EAVESECTION @ GIRT
CLOSURES
TYPICAL SECTION @CLOSURE
CLOSURE DETAIL @PURLINS
CLOSURE DETAIL @RIDGE PURLINS
EAVESTRUT
CLOSURE
BASEMEMBER
CONCRETE
LINER SHEET
GIRT
LAP AS REQ'D ANDATTACH W/ (4) POPRIVETS
CLOSURE (TYP.)
ATTACH TO GIRTW/ WALL STRUCT.FASTENERS (2) PERCLOSURE
ROOF SHEET
EAVE STRUT
ATTACH TO FLOORW/ RAMSET OROTHER APPROVEDMETHODS OFFASTENING.
7'-6
"5'
-0"
GIR
TPE
R B
LDG
.SP
ACES
REQ
UIR
EMEN
T
PURLIN
PURLINCLOSURES
FIELD CUT ANDLAP AT RIDGE.ATTACH WITH(2) POP RIVETS
WALL STRUCT.FASTENERS
WALL STRUCT.FASTENERS
LAP AS REQ'DAND ATTACH W/(4) POP RIVETSPURLIN
CLOSURE
PURLINSPACING
PURLINROOFSHEET
CLOSURE
TRIM
PARTITIONSHEET
WALL SHEET
VP PURLIN & GIRT CLOSURES / INSTALLATIONC-17
03/15/14
RAKE FASCIA EAVE CLOSURE ASSEMBLY(WITH EAVE GUTTER)
45
SPREAD BIRD STOPFROM RAKE FASCIATO SLIDE ROOFSHEET IN-BETWEEN.
TAPE MASTIC
SLIDE RAKE FASCIAUP ROOF SHEET UNTILCLOSURE ASSEMBLYBUMPS CORNER TRIM.
CORNERTRIM
ROOFSHEET
RAKE FASCIA EAVE CLOSURE ASSEMBLY(WITHOUT EAVE GUTTER)
SIDE WALLSHEET
ATTACH RAKE FASCIA (WITH EAVE CLOSUREASSEMBLY) TO ROOF WITH ROOFFASTENERS AS SHOWN IN ERECTIONDETAILS SUPPLIED WITH JOB DRAWINGS.
INSTALL CORNER CAPWITH (6) POP RIVETS.
INSTALL PANEL RIB FILLERWITH POP RIVETS WHILEON THE GROUND.
(5)
(3)
CUT AWAY SHADEDAREA AS SHOWN.
POSITION GUTTER ON BUILDING WITH ENDFLUSH WITH OUTER EDGE OF CORNER.
(2)GUTTER
GUTTER ENDCLOSURE
BIRD STOP 2 1 2"
POSITION RAKE FASCIA ON BUILDING.SLIDE DOWN ROOF UNTIL END BUMPSGUTTER LIP. ATTACH FASCIA TOBUILDING WITH ROOF FASTENERS ASSHOWN.
(4)
ROOF FASTENERS TO BEINSTALLED PER ERECTIONDETAILS SUPPLIED WITH JOBDRAWINGS.
INSTALL GUTTER ENDCLOSURE (REF. GUTTERASSEMBLY & SEALANTPROCEDURES) THENINSTALL BIRD STOPWITH POP RIVETS ASSHOWN.
(1)
1"
ROOF FASTENER
EXTERIOR TRIM / IDENTIFICATION & APPLICATIOND-1
10/01/09
FASCIA SPLICE
INSTALL FASCIA
WALL PANEL
OUTSIDE CLOSURE
TAPE MASTIC
ROOF PANEL
RAKEFASCIA
BRONZESKINNINGSEALANTBELOW
ROOFFASTENER
18" DIA. BLIND
RIVET (5) PERSPLICE 3" LAP
RAKEFASCIA
ROOFSTRUCTURALFASTENER
TAPE MASTIC
OUTSIDECLOSURE
WALL STITCHFASTENER
SEE ERECTION DRAWINGDETAILS FOR FASTENERTYPE AND SPACING.
EXTERIOR TRIM / IDENTIFICATION & APPLICATIOND-2
03/15/14
EAVE FASCIA
BLBL
CORNER TRIM
FIELD CUT TOPOF TRIM ONLY(AS REQ'D.)
WALL PANEL
ATTACHWITH WALLSTITCHFASTENERSAT 12" O.C.
START AT BOTTOM OF WALL PANELAND WORK UP WITH UPPER PIECESLAPPING OVER LOWER ONES FORWATER SHED.
CORNER TRIM
EAVEFASCIA
LAP MINIMUM OF 3"AT SPLICE POINTS.(3) POP RIVETSREQ'D. PER SPLICE.
OUTSIDECLOSURE
ROOFPANEL
INSIDE CLOSUREWITH TAPE MASTICBOTH SIDES OFCLOSURE.
ROOF STITCHFASTENERS AT 12"O.C. (MINOR RIBSONLY)
EXTERIOR TRIM / IDENTIFICATION & APPLICATIOND-3
03/15/14
SHEET METAL PEAK CAPWITH RAKE FASCIA RIB CAP
PLASTIC PEAK CAP
DETAILS SHOWN ARE FOR PANEL RIB ROOF ONLY
APPLY TAPE MASTICUNDER PEAK CAP
PEAK CAP TO LAP RAKEFASCIA A MINIMUM OF3" AND ATTACHED WITH(10) POP RIVETS TOPAND FRONT
PLASTIC PEAK CAP(PPC__)INSTALLEDOVER RAKE FASCIA
RAKE FASCIA
APPLY TAPE MASTICUNDER RIB CAP.
RAKE FASCIA
POP RIVETS
SHEET METALPEAK CAP(SPC__)
APPLY TAPEMASTIC UNDERRIB CAP.
PEAK RIB CAP (PRC)INSTALLED OVER PEAK CAPAND RAKE FASCIA ASSHOWN.
EXTERIOR TRIM / IDENTIFICATION & APPLICATIOND-4
07/28/15
FIG. C: SEALANT APPLICATION
FIG. B: ASSEMBLY
FIG. A: FIELD TRIM LOCATIONS
GUTTER ENDCLOSURE
1"10
9
8
13
2
45
6
7
GUTTER ENDCLOSURE
14" BEAD
SEALANT
Place gutter end closure inposition as shown in FIG. B andcheck for proper nesting.
Trim as required 116" to 18" atlocations shown in FIG. A toinsure proper nesting.
Locate gutter end closure inplace 1" from gutter end asshown in FIG. B.
1.
2.
3.
PROCEDURE:
Secure gutter end closure inplace with standard 18" poprivats. IMPORTANT: Fasten insequence as shown in FIG. B.
4.
Apply 1 4" fillet bead ofrecommended gun gradesealeat inside gutter at jointconnection. FIG. C.
5.
GUTTER ASSEMBLY & SEALANT PROCEDURESD-5
12/14/12
DOWNSPOUT LOCATIONFIG. B
160' MAX.
160' MAX.
987
13
2
54
6FIELD TRIM
GUTTER
1 1/2"
DOWNSPOUT LOCATIONFIG. A
EXPANSION JOINT(FOR BUILDINGS OVER 160' IN LENGTH)
GUTTER SPLICE ASSEMBLY
FIELD FABRICATECOVER FOR USEOVER GUTTERGAP
GUTTER ENDCAPS
GUTTERSTRAP
34" GAP
34" PLUS
END CAPDIM'S.
5"
4"
14"
SEALANT
18" BLIND RIVET
SEALANT
DOWNSPOUTNIPPLE. SETNIPPLE INSEALANT.ATTACH TOGUTTER WITH(8) 18" BLINDRIVETS.
APPLY LIBERALAMOUNT OFSEALANT OVERALL BLINDRIVETS (INSIDEGUTTER)
CUT MATERIAL FROM GUTTER PAN AT DIMENSIONSSHOWN IN FIG. A.
INSTALL NIPPLE AS SHOWN IN DETAIL BELOW.
1.
2.
NIPPLE INSTALLATION:
PROCEDURE: GUTTER ASSEMBLY
Field trim back flange of outsidegutter section as shown in FIG.B. "GUTTER SPLICEASSEMBLY"
Apply 1 4" bead of recommendedgun grade sealant 1" from gutteredge as shown in FIG. B.
Place gutter sections togetherwith 1 12" Lap.
Secure gutter sections togetherstandard 1 8" blind rivents.IMPORTANT: FASTEN INSEQUENCE AS SHOWN INFIG. B.
1.
2.
3.
4.
18" BLIND RIVET
GUTTER ASSEMBLY & SEALANT PROCEDURESD-6
03/15/14
Panel closure angle, outsideclosures, inside closures and tapemastic must be in place before eavegutter can be installed.Gutter strap must have tape masticapplied to bottom side beforeinstallation.Install gutter strap with one roofstructural fastener into eave strut.Hang gutter, position, then attach toroof panel.Attach straps to gutter and roofpanel edges.
1.
2.
3.
4.
SECTION AT EAVE
SECTION THRU GUTTER STRAP
5.
APPLY TAPE MASTICTO BOTH SIDES OFCLOSURE. TAPE MASTIC
GUTTER STRAP
ROOF PANEL
ROOF STRUCTURALFASTENER (1 PERSTRAP)
ROOFSTRUCTURALFASTENER
GUTTER STRAP3'-0" O.C.
ROOF STITCHFASTENER 12" O.C.
INSIDECLOSURE
SIDEWALLSTITCHFASTENER12" O.C.
PANELCLOSUREANGLE
OUTSIDECLOSURE
EAVESTRUT
ROOF STITCHFASTENER (2PER STRAP)
EAVEGUTTER GUTTER
STRAP
TAPE MASTICON TOP OFGUTTER STRAP
PANELCLOSUREANGLE
INSIDECLOSURE
TAPEMASTIC
GUTTERSTRAP
EAVEGUTTER
SEE ERECTIONDETAILS FOROVERHANG DIM'S.
GUTTER INSTALLATIOND-7
03/15/14
DOWNSPOUT INSTALLATIOND-8
03/15/14
MULTI/VALLEY GUTTER
END CLOSURE
BUILDING TRIM INSTALLATION / VALLEY-GUTTER
GUTTER ASSEMBLY
PURLINDOWNSPOUT (NBVP)
INSIDECLOSURE
PANEL RIBROOF SHEET
ROOF STRUCTURAL FASTENERS(TYPICAL AS SHOWN)
NIPPLE (NBVP)
NOTE:REFER TO ERECTIONDETAILS SUPPLIED WITHJOB DRAWINGS FORROOF SHEET OVERHANG.
(VALLEY GUTTER SHOWN, MULTI GUTTER SIMILAR)
-Details shown are VP BUILDINGS standards. Builder can specify tapered rigid board in lieu of drain wedges (RIGID BOARD NOT BY VP BUILDINGS)
-Do not walk or stand in gutter.
for installatiuon procedures. BUILDINGS. Refer to manufacturers instructions-Liners, rigid board and adhesives are NOT BY VP
are NOT BY VP BUILDINGS.-Install scuppers as required by local code. Scuppers
the installation of the roof sheets.-Interior gutters and liners to be installed prior to
-Downspouts and downspout nipples are NOT PROVIDED BY VARCO PRUDEN. Welding of nipples to galvanized gutter is not recommended.
galvanizing (N.B.V.P.). interior gutters should be touched up with cold -Scratches and abrasions to the galvanized finish of the
-Interior gutters are to be installed level.
BUILDING TRIM INSTALLATION / INTERIOR GUTTER D-9
03/15/14
INSIDE CLOSURE WITHCONTINUOUS TAPEMASTIC ON BOTH SIDES.
STRUCTURAL ROOFFASTENER AT EACHMINOR RIB (3/FOOT)
LINER (NBVP)
(GDW-)DRAIN WEDGE
VALLEY GUTTEROR MULTI GUTTER
BOARD (NBVP)1/2" RIGID
BUILDING TRIM INSTALLATION / MULTI-GUTTERD-10
03/15/14
WP
ROOF STITCH FASTENER 6"O.C. FOR FIRST 10' FROMEAVE.
ROOFSTRUCTURALFASTENER (3)PER FOOT.
TAPE MASTIC
3" PIECE OF TAPEMASTIC
ROOF STRUCTURALFASTENER (3 PER FOOT)
316" BEAD OF NON-SKINNING
TUBE SEALANT FOR FIRST 10'FROM EAVE.
MASTIC DETAILS
OPTIONAL PLUG ATTACHMENT
1 2"
1'-0"O.C.
1'-0"O.C.
WIDE TAPEMASTIC OVERCLOSURE PLUG
(2) LAYERSWIDE TAPEMASTIC Refer to SED's for tape mastic sizes per location.
Apply (1) rows wide tape mastic 1/2" upslope fromwork point.Install closure plug to align with panel rib majorribs.Cut (1) 5" long piece of wide tape mastic and placeover top of plug.After installing sidelap mastic, install a 3" pigtail oftape mastic from top of the rib down to mastic.Apply 316" bead of non-skinning sealant to the wetside of the sidelap (UNDER THE ANTI-CAPILLARYBEAD) for the frist 10' from the eave.Install next panel and fasten sidelap with roof stitchfastener at 6" O.C. for frist 10' from the eave.Fasten eave end of panels with roof structuralfastener in minor ribs (3 PER FOOT).Use miter cut closure plugs at the valley conditionbetween intersecting buildings. Install mastic asdescribed above. Install fasteners in flat of panel atmaximum 3" O.C.
INSTRUCTIONS
1.
2.
3.
4.
5.
6.
7.
8.
HARD RUBBER CLOSURE PLUG AT VALLEYSD-11
03/15/14
PANEL RIBHARD RUBBERCLOSURE PLUG
MULTI-GUTTERDETAIL AT RAKE FASCIA EAVE GUTTER
CONT. RIDGE VENT
LEAN-TO
EAVE SOFFIT
EAVE FASCIA
INSIDE CLOSURE OUTSIDE CLOSURE
EAVEGUTTER
PANEL RIBWALL
PANELRIB
OUTSIDECLOSURE
INSIDE CLOSURE INSTALLWITH ROOF STITCHFASTENER IN MINOR RIBS.
VENTILATOR
FRAMING
PANELRIB
PANELRIB
FLASHING
INSIDECLOSURE
3'-0"3'-0"
PANEL RIBROOF
PANEL RIBSOFFIT
PANEL RIBROOF
EAVEFASCIA
PANEL RIBROOF
MULTI-GUTTER
RAKEFASCIA
PANEL RIB
OUTSIDE CLOSURE ATTACHES WITHWALL STITCH FASTENERS AT MAJORRIBS.
INSIDE CLOSURE WITH ROOFSTRUCTURAL FASTENER ATEACH MINOR RIB AT EAVEMEMBER.
OUTSIDE CLOSURE use std. purlinfastener arrangment for attachingroof panel. Locate closure belowfastener heads-attach ridge vent andclosure with VP-200 rivets located atthe major ribs of each roof panel.
INSIDE CLOSURE at top use roofstitch fastener at 12" O.C.
OUTSIDE CLOSURE at bottom attachwith wall stitch fasteners at majorribs.
OUTSIDE CLOSURE use std.purlin fastener arrangementfor attaching roof panel.Locate closure below fastenerheads. Attach flashing andclosure with roof stitchfasteners at major ribs of eachroof panel.
OUTSIDE CLOSURESoffit trim attached with wallstitch fasteners located at eachmajor rib of wall panel.
PANEL RIB CLOSURE / TYPES & APPLICATIOND-12
03/15/14
Design and recommended installation procedures are subject to change at any time, due to continued development work by Varco Pruden Buildings.
• • •All panels formed from light gauge metal may exhibit waviness, also known as “Oil-Canning,” commonly occurring in, but not restricted to, flat portions of a panel. This inherent characteristic is not a defect of material or manufacturing and is not cause for rejection.
• • •For field installation questions, call your local VP Service Center. The job number is included on all building plans:Arkansas: ..................................870-534-6030California: ...................................209-667-4951Missouri:.....................................816-238-7550North Carolina: ...........................336-996-4801Wisconsin: ..................................608-882-5000
Varco Pruden Buildings, 3200 Players Club Circle, Memphis, TN 38125©2012 BlueScope Buildings North America, Inc. All rights reserved.Varco Pruden Buildings® is a division of BlueScope Buildings North America, Inc.
4003 Basic Panels and Accessories Form: EG-902931 Issue Date: 2010Revision: 3 Revised: 2/14