bch range of motor starters eng 57216

Upload: rikumohan

Post on 04-Apr-2018

222 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/29/2019 Bch Range of Motor Starters Eng 57216

    1/6

    BCH MOTOR STARTERS

    A Range of Motor Starters for every need....

  • 7/29/2019 Bch Range of Motor Starters Eng 57216

    2/6

    BCH Motor Starters

    BCH Motor StartersContactor

    Overload Relay

    REVERSING DOL UPTO 20 HP

    DOL UPTO 30 HP

    STAR DELTA UPTO 250 HP

    Automatic Time Delay Relay

    The Time Delay Relay used in Automatic Star Delta Starter has superb repeat accuracy, gives satisfactory

    performance in frequent starting applications.

    AC Contactor having high grade moulding for extremely long life.

    Low bounce and weld resistant contacts of silver cadmium oxide

    Encapsulated Coil

    : Shock proof and moisture proof

    : Withstands large voltage fluctuations.

    Overload protection in motor is achieved through the relay fitted in

    the starter. The range of current setting on any relay is

    between 100% to 160% of its minimum setting

    Single phasing protection through the relay's sensitive differential mechanism

    Protection against unbalanced voltage

    Tripping Characteristics

    TRIPPINGT

    IME

    (SECONDS)

    10

    1

    100

    1,000

    10,000

    MAX.

    MIN.

    NOM.

    THREE PHASE

    MULTIPLE OF FULL LOAD/TRIP CURRENT

    10.5 11

    10

    100

    1,000

    10,000

    TRIPPINGT

    IME(SECONDS)

    MULTIPLE OF FULL LOAD/TRIP CURRENT

    MAX.

    NOM.

    MIN.

    TWO POLE

    10.5 1

    Direct Operated Relay

    DOL and Star Delta Starter

    10.5 1

    MAX.

    MIN.

    1

    10

    100

    1,000

    10,000

    TRIPPINGT

    IME(SECONDS)

    MULTIPLE OF FULL LOAD/TRIP CURRENT

    NOMINAL

    CT Operated Relay

    .5 .100 101

    104

    103

    102

    101

    100

    TRIPPINGT

    IME

    IN

    SECONDS(ts)

    MULTIPLE OF FULL LOAD CURRENT X I

    Mini Manual Starter

    MANUAL STAR DELTA UPTO 5 HP

    BCH Starters meet the need of high reliability in a wide range of applications. These are suitable for switching

    AC Motors upto 250HP (185KW) 415V three phase and offer complete motor protection against overloads,

    single phasing and severe unblanced voltages in accordance with IEC specifications.

  • 7/29/2019 Bch Range of Motor Starters Eng 57216

    3/6

    MOTOR OUTPUT

    415V

    (3 PHASE 50 HZ.)CONTACTOR

    AC-3 Rating

    BACKUP

    PROTECTION

    HRC FUSE

    TYPE GII/GL

    (AMP)

    OVERLOAD

    RELAY RANGE

    AMPERES

    (PHASE

    CONNECTED)

    CATALOGUE CODE

    KW

    2.23.7

    7.5

    11.0

    15.0

    18.5

    26.0

    30.0

    37.0

    55.0

    67.5

    75.093.0

    110.0

    150.0

    187.0

    HP

    3.05.0

    10.0

    15.0

    20.0

    25.0

    35.0

    40.0

    50.0

    75.0

    90.0

    100.0125.0

    150.0

    200.0

    250.0

    2.4 - 3.83.8 - 6.0

    6.0 - 9.3

    8.9 - 13.5

    13.2 - 20.0

    17.4 - 24.0

    22.0 - 30.0

    24.4 - 39.0

    37.6 - 60.0

    37.6 - 60.0

    56.4 - 90.0

    56.4 - 90.084.6 - 135.0

    84.6 - 135.0

    131.6 - 210.0

    131.6 - 210.0

    16A16A

    16A

    16A

    25A

    25A

    40A

    40A

    40A

    70A

    70A

    110A110A

    110A

    200A

    200A

    NASAGLENNASAHLEN

    NASAJLEN

    NASAKLEN

    NASALLEN

    NASAMLEN

    NASANLEN

    NASACT1LEDM

    NASACT2LEDM

    NASACT2LEEM

    NASACT3LEEM

    NASACT3LEC5M

    NASACT4LEC5M

    NASACT4LEC5M

    NASACT5LEC6M

    NASACT5LEC6M

    NASSGLENNASSHLEN

    NASSJLEN

    NASSKLEN

    NASSLLEN

    NASSMLEN

    -

    -

    -

    -

    -

    --

    -

    -

    -

    1016

    20

    32

    35

    50

    63

    80

    80

    100

    125

    160

    200

    200

    300

    300

    AUTOMATIC

    STAR DELTA

    STARTER

    SEMI- AUTOMATIC

    STAR DELTA

    STARTER

    Star Delta Starter

    * Also available starters for reversing function. For details consult us.

    MOTOR OUTPUT

    415V 3 PHASE 50 HZ. CONTACTOR

    AC-3 Rating

    BACKUP

    PROTECTION

    HRC FUSE

    TYPE GII/GL

    (AMP)

    OVERLOAD

    RELAY

    RANGE

    AMPERES

    STARTER

    CATALOGUE

    CODEKW

    0.37

    0.55

    0.75

    1.5

    2.2

    3.7

    5.5

    7.5

    11.0

    15.0

    18.5

    22.0

    HP

    0.5

    0.75

    1.0

    2.0

    3.0

    5.0

    7.5

    10.0

    15.0

    20.0

    25.00

    30.0

    0.72-1.14

    1.07-1.7

    1.58-2.5

    2.4-3.8

    3.8-6.0

    6.0-9.3

    8.9-13.5

    13.2-20.0

    17.4-24.0

    22.0-30.0

    24.4-39.0

    37.6-60.0

    16A

    16A

    16A

    16A

    16A

    16A

    16A

    16A

    25A

    40A

    40A

    40A

    NADLEN

    NAELEN

    NAFLEN

    NAGLEN

    NAHLEN

    NAJLEN

    NAKLEN

    NALLEN

    NAMLEN

    NANLEN

    NACT1LEN

    NACT2LEDM**

    4

    6

    10

    16

    20

    25

    35

    50

    63

    63

    100

    100

    Three Phase - DOL Starter

    Selection Chart

    Type Cat. Contactor Size Relay Range

    Code Rating (Amp.)

    NAGBW-SP 16A 2.4-3.8

    NAHBW-SP 16A 3.8-6.0

    NAJBW-SP 16A 6.0-9.3NAKBW-SP 16A 8.9-13.5

    NALBW-SP 25A 13.2-20.0

    Single

    Phase

    DOLStarter

    Single Phase Motor Starter

    (with 2 Pole Contactor + 2 Pole Relay)

  • 7/29/2019 Bch Range of Motor Starters Eng 57216

    4/6

    BCH Sumbersible Pump Starter (SPS)

    Three PhaseDirect on line : upto 24 A relay rating

    Star Delta : upto 39 A relay rating

    Salient Features :

    Protections :

    Phase failure

    Phase imbalance

    Phase reversal

    Short Circuit Protection through

    MCB : In case of Premium models

    Ammeter and Voltmeter

    On/Off and Trip indications

    Powder coated enclosure with PU gasket ensuring

    excellent finish and reliability

    Provision for connecting Dry run preventor/LLC relay

    With Mini DOL (up to 11.0-20. A Relay)

    With 2 Pole Contactor + 2 Pole Relay (up to 23-32 A Relay)

    Single Phase

    The Product offer :

    Three Phase (SPS)-DOL & Star Delta

    Cat. No. Range

    CPPANAJ* 6.0 - 9.3

    CPPANAK* 8.9 - 13.5

    CPPANAL* 13.2 - 20.0

    CPPANAMN 17.4 - 24.0

    CPSDEAJ# 6.0 - 9.3

    CPSDEAK# 8.9 - 13.5

    CPSDEALN 13.2 - 20

    CPSDEAMN 17.4 - 24

    DOL

    Star Delta

    1-Phase SPS With 2 Pole Contactor+Relay(With Ammeter+Voltmeter)

    Cat. HP Relay Range (Amp.) Run Capacitor(mfd) Start Capacitor (mfd)

    CPNSHBW-SP0.5 HP

    3.8-6.0 25 80/1000.75 HP

    CPNSJBW-SP 1 HP 6.0-9.3 36 100/120

    CPNSKBW-SP 1.5 HP 8.9-13.5 50 120/150

    CPNSLBW-SP 2 HP 13.2-20.0 36+36 150/200

    CPNSMBW-SP 3 HP 17.4-24.0 50+50 200/250

    CPNSPBW-SP 5 HP 23-32 50+50+50 200/250

    On/Trip Indicators

    Weather prooAuto manual Switc

    Weather proofAuto manual Switch

    Phase indicator(For std & Premiu

    models

    Phase indicators(For std & Premium

    models)

    Properly laid down wires, bunched with cable tiesFerrules for ease of identification

    Isolated Terminal blocksfor better termination

  • 7/29/2019 Bch Range of Motor Starters Eng 57216

    5/6

    Direct-On-Line, manually operated, Mini Starter is designed for non-

    reversing control of all types of squirrel cage motors with an intermittent

    duty of 15 starts per hour (utilisation category AC3) complying withperformance requirements of IEC-292 It is capabl e of switching

    motors upto 10HP, 415V, 3Phase or 3 HP single phase.

    The starter unit comprises of a double break, on load switch operated

    by means of a toggle link mechanism. Adjustable bimetalic thermal

    overload strips are included which can be set to follow closely the

    heating characteristics of the motor.

    Mini Manual Starter (Upto 10 Hp)

    Selection Chart

    ** Substitute E by C for flush mounting.

    2

    2

    6

    10

    20

    25

    50

    0.23-0.47

    0.46-0.8

    0.85-1.55

    1.60-3.20

    3.50-6.50

    6.80-11.70

    11.00-20.00

    AMLE 10

    AMLE 20

    AMLE 30

    AMLE 40

    AMLE 50

    AMLE 60

    AMLE 70

    CATALOGUE** CODERECOMMENDED

    FUSE

    (AMPS)

    RELAY RANGE

    AMPS

    0.5

    0.75

    1.0

    1.5

    3.0

    5.0

    10

    0.37

    0.52

    0.75

    1.10

    2.20

    3.70

    7.5

    1/6

    1/6

    0.5

    0.75

    1.0

    2.0

    3.0

    HP KW

    SINGLE PHASE 230V1 PHASE3 PHASE

    0.095

    0.13

    0.37

    0.52

    0.75

    1.50

    2.20

    KW

    RECOMMENDED HP (KW)

    AMLE 10-SP

    AMLE 20-SP

    AMLE 30-SP

    AMLE 40-SP

    AMLE 50-SP

    AMLE 60-SP

    AMLE 70-SP

    3PHASE 415V

    HP

    Utilisation category AC 3 as per IEC 292-1

    Insulation voltage 600V

    Thermal rating 20A

    Operational current Ie 16A at 415V

    Frequency of operation 15 operation per hour

    AC3 rating 16A at 415V, 50Hz

    Mechanical life 1x105operations

    Enclosure category Sheet steel enclosure to IP 51

    Terminal capacity One cable of 6 mm2or two cables of 4 mm

    2

    Characteristics

  • 7/29/2019 Bch Range of Motor Starters Eng 57216

    6/6

    Direct-On-Line Starter

    360.0

    215.0

    280.0

    7.0 DIA. 4MTG. HOLES

    11.0

    36.0

    162.0

    315.0

    DOL STARTER 30 HP.

    39.0 DIA. 4 HOLESFOR CONDUIT

    5 5DIA. 4MTG. HOLES

    146.0

    180.0

    96.0

    130.0

    11.0

    160.0

    30.0

    60.0

    4 HOLES DIA. 26.5

    FOR CONDUITS

    7.0 DIA. 4MTG.

    280.0

    129.0

    180.0

    11.0

    'A'36 4 HOLES DIA

    33.0 FORCONDUITS

    217.0

    DOL STARTER 20 & 25 HP

    25 HP DOL. 162.020 HP DOL. 120.0

    DESCRIPTION DIMN. 'A'

    40 & 50 HP AUTO STAR DELTA STARTER (WITH SIZE-D)

    400.0

    75X38X6M.S.CHANNEL 2NOS.

    365.0

    CABLE ENTRY

    200X70

    13.5 DIA. 4POLES FOR WALL MOUNTING

    706.

    0

    750.0

    75.0

    14.0 DIA. 4HOLESFOR FLOOR MTG. 1

    1.0

    172.0

    212.0

    82.0

    45.0

    200.0

    11.0 .40.0

    556.0

    AUTO STAR DELTA STARTER 90/70 HP (WITH SIZE-E)

    AND 100/150HP(WITH SIZE-M5)

    510.0

    600.0

    CABLE ENTRY250X100

    600.0

    75.0

    240.0

    155.0

    22.5

    14.0 DIA. 4HOLESFOR MOUNTING

    13.5 DIA. 4 HOLESFOR WALL MOUNTING

    315.0

    80.0

    39.0 DIA. HOLEFOR CONDUIT

    26.5 DIA.3 HOLESFORCONDUIT

    215.0

    280.0

    162.0

    36

    360.0

    11.0

    STAR DELTA STARTER 40HP (WITH NHD1)

    215.0

    280.0

    120.0

    36

    360.0

    7.0 DIA. 4 MTG. HOLES

    26.5 DIA. 3HOLESFOR CONDUIT

    39.0 DIA. HOLES

    FOR CONDUIT

    80.0

    315.0

    SEMI AUTO & AUTO STAR DELTA STARTER UPTO 35HP

    11.0

    7.0 DIA. 4 MTG. HOLES

    DIMENSIONS (mm)

    Star Delta Starter

    Corporate Office/International Div.: 1105, New Delhi House, 27, Barakhamba Road, New Delhi - 110 001(India)

    Tel. : +91-11-23316029/41511350 Fax : +91-11-23715249 E-Mail : [email protected]

    Registered Office :Block 1E, 216, Acharya Jagadish Chandra Bose Road, Kolkata - 700 017

    Works : 20/4, Mathura Road, Faridabad - 121 006 (Haryana)

    Tel. : +91-129-4063000/4061026 Fax : 0129-2304024

    Representative