IBM BladeCenter Interoperability Guide

1

IBM BladeCenter

The Right Choice – Open, Easy, Green

Interoperability Guide

2007 Week 51, Version 1.1

IBM BladeCenter Interoperability Guide

2

Document Purpose: Quick reference for BladeCenter Interoperability. Compliment to ServerProven, COG, and the Configuration tools with ServerProven being the most reliable, accurate, and up to date tool.

This paper is intended to provide information regarding BladeCenter Interoperability. It assembles data from other published IBM tools. Findings may not be realized in all customer environments, and implementation in such environments may require additional steps, configurations, and performance analysis. The information herein is provided “AS IS”“ with no warranties, express or implied. This information does not constitute a specification or form part of the warranty for any IBM, Brocade, Cisco, Emulex, McData, Myrinet, NetXen, Nortel, or QLogic products.

http://www-03.ibm.com/servers/eserver/serverproven/compat/us/ Tools Website: http://www-03.ibm.com/systems/x/configtools.html

compatibility

Compatibility for BladeCenter products The IBM ServerProven® program validates selected products for compatibility with IBM System x™, BladeCenter® and xSeries® servers. Through the ServerProven Program, IBM works with industry leaders to test their equipment with ours. We recognize that you deserve the most innovative solutions...even if they're not all from IBM. IBM ServerProven provides compatibility information only. Hardware configuration guidance can be obtained from the Configuration and Options Guide. Product ordering information can be obtained from the Sales Configurators. These configurators can be accessed through the link "Configuration Tools" which is located on the left side of this page.

IBM BladeCenter Interoperability Guide

3

Terminology aMM Advanced Management Module CFFh Combo Form Factor Horizontal I/O Expansion Card CFFv Combo Form Factor Vertical I/O Expansion Card cMM Chassis Management Module cMM2 Chassis Management Module II EC I/O Expansion Card

HSEC High Speed I/O Expansion Card

HSFF = High Speed Form Factor

LFF HSEC Large Form Factor High Speed I/O Expansion Card

MSIM Multi Switch Interconnect Module

NEBS Network Equipment-Building System

OFM Open Fabric Manager

OPM Optical Pass-Thru Module

SFF = Small Form Factor (enables second HDD on select blade servers)

SFF EC Small Form Factor I/O Expansion Card StFF = Standard Form Factor

IBM BladeCenter Interoperability Guide

4

Blades & Management Modules to Chassis Interoperability Blade Servers S E T1 H HT1

HC10 (7996) Y Y - - - HS20 (8832, 8843) Only 8843 Y Y Y Y HS21 Dual Core (8853) Y Y Up to 65W Y Up to 80W

HS21 Quad Core (8853) Y Up to 80W Up to 7 at 80W Y Up to 10 at

120W2 HS21 XM Dual Core (7995) Y Up to 80W Up to 65W Y Up to 80W

HS21 XM Quad Core (7995) Y Up to 80W Up to 7 at 65W2 Y Up to 12 at

80W LS20 (8850) Y Y Y Y Y LS21 (7971) Y Y4 Up to 68W Y Y LS41 (7972) Y Y4 Up to 68W Y Y JS20 (8842) - Y Y Y Y JS21 (7988) - Y6 Y6 Y Y JS22 (7998) - - - Y Y QS20 (0200-250) - Y - - - QS21 (0792) - - - Y Y7

Management Modules

Management Module - Y - - - Advanced Management Module (aMM) Y Y - Y Y Chassis Management Module (cMM) - - Y - - Chassis Management Module II (cMM2) - - Y - -

Notes:

Y = no restrictions on the number of blades, all blade slots may be used W = CPU power in watts Note-1 Non NEBS environment (see table at end of documents for NEBS statements)

Note-2 If fully configured, must leave 1 slot open in power domain 1

Note-3 When fully configuring a BC-E (8677) chassis with the maximum possible HS21 XM blade server

configuration (fourteen HS21 XM blade servers, each with two 80W processors, eight 4GB memory DIMMs,

one SAS HDD, one USB-based flash drive, one I/O card and one cKVM card), there could be periods of time

that Power Domain 2 exceeds the 13.5amp rating guidance (Power Domain 1 will not exceed the rating

guidance). While this is not violating any safety rules, we recommend that your clients review the electrical

infrastructure and power distribution of their installations to account for a peak of 14.4A

Note-4 95W is supported but will throttle performance to fit in power envelope – recommend using in BladeCenter H or HT. This is true for processor models 22xx and 82xx. They will run n-2 speed in BladeCenter E and BladeCenter T chassis. However, processor models 23xx and 83xx do not have the ability to run n-2. They are not supported in BCE or BCT. Note-5 HC10 (7996) requires AMM on E chassis.

Note-6 When the JS21 blade boots, the BMC will determine what chassis it is running in and "set" accordingly the processor frequency. The 2-way configuration functions at 2.7GHz processor frequency in BladeCenter H (8852) or 2.6GHz processor frequency in all other BladeCenter chassis. The 4-way configuration functions at 2.5GHz processor frequency in BladeCenter H (8852) or 2.3GHz processor frequency in all other BladeCenter chassis. Note-7 Supported only in Non-NEBS environment

IBM BladeCenter Interoperability Guide

5

Blades to Expansion Units Interoperability

Blade Servers Storage I/O 39R7563

Memory I/O 42C1600

Multi-Proc Unit

26K5934

PCI Expansion

Unit II 25K8373

HC10 - - - - HS20 (8843) - - - Y HS21 Dual and Quad Core Y Y - Y HS21 XM Dual and Quad Core Y - - Y LS20 - - - - LS21 Y - - - LS41 Y - Y - JS21 - - - - JS22 - - - - QS20 - - - - QS21 - - - - Note-1 If you need support on the PCI Expansion Unit II (PEU2) for the LS21/41, contact your IBM Representative. IBM System x Sales representative, a SPORE is required to execute the LS21/41 on PEU2 solution.

Blades & Expansion Units Interoperability

Expansion Units # CPU

RAID Contr

ol.

# HDD

Memory

DIMM Slots

On Board NICS

Exp Slot 1

Exp Slot 2

Exp Slot 3

Storage and I/O Expansion Unit 0 Y 3 0 0 Note 1 Note 2 Note 3 Memory and I/O Expansion Unit 0 - 0 4 2 N Note 2 Note 3 Multi-proc Expansion Unit 2 - 1 8 2 N Note 2 Note 3 Note 1: Either StFF of SFF card can be used in slot

Note 2: Either StFF, SFF of CFFv can be used in slot (when StFF or SFF is installed, CFFh cannot

be in adjacent slot)

Note 3: HSEC or CFFh can be used in slot (when HSEC is installed, StFF or SFF cannot be in

adjacent slot)

IBM BladeCenter Interoperability Guide

6

I/O Modules to Chassis Interoperability

P/N I/O Module S E T H HT MSIM

SAS 39Y9195 IBM BladeCenter SAS Connectivity Module Y Y Y Y Y 3 Ethernet 32R1892 Cisco Systems Intelligent Gb Ethernet Switch - Y Y Y Y 1 32R1888 Cisco Systems Intelligent Gb Fiber Ethernet Switch - Y Y Y Y 1 32R1859 Nortel Layer 2-7 Gb Ethernet Switch Y Y Y Y Y 3 32R1860 Nortel Layer 2/3 Copper Gb Ethernet Switch Y Y Y Y Y 1 32R1861 Nortel Layer 2/3 Fiber Gb Ethernet Switch Y Y Y Y Y 1 39Y9324 Server Connectivity Module Y Y Y Y Y 1 32R1783 Nortel 10G Uplink Ethernet Switch Y Y Y Y Y 1 39Y9267 Nortel 10G Ethernet Switch Module for IBM BladeCenter - - - Y Y 3 InfiniBand 32R1900 Cisco Systems InfiniBand Switch Module - Y Y Y Y 3 32R1756 Cisco Systems 4X InfiniBand Switch Module - - - Y Y 3 39Y9211 QLogic InfiniBand Fibre Channel Bridge Module - - - Y Y 3 39Y9207 QLogic InfiniBand Ethernet Bridge Module - - - Y Y 3 43W4419 4x InfiniBand Pass-Thru Module - - - Y Y 3

Note 1: Supported in left I/O Module bay of MSIM

Note 2: Supported in right I/O Module bay of MSIM

Note 3: Not supported or not applicable for use with MSIM

Note 4: OPM is supported in MSIM for Ethernet in left I/O module bay or Fibre Channel in right I/O module bay Note 5: (MSIM) - The I/O slot position support with MSIM is dictated by the current CFFh combo card design (2pt Enet + 2pts FC) 39Y9306 OPM is limited to 2GB Fibre channel data rate (4GB FC cards have to be configured for 2GB if connected to OPM)

IBM BladeCenter Interoperability Guide

7

I/O Modules to Chassis Interoperability continued A Brocade SAN Switch Module for BladeCenter or any other Brocade switch or director utilizing the Fabric OS Access Gateway mode can connect to an INCITS T11 NPIV compliant device. The Brocade Access Gateway mode was designed to adhere to this standard. In addition, any INCITS T11 NPIV compliant device can connect to a Brocade switch or director that supports NPIV connectivity. Brocade does not test or make a discreet statement of support for any other vendor’s devices. Brocade will assist IBM with problem determination for compliant configurations.

P/N I/O Module S E T H HT MSIM

Fibre Channel 32R1812 Brocade 20 port – 4Gb SAN Switch - Y Y Y Y 2 32R1813 Brocade 10 port – 4Gb SAN Switch Y Y Y Y Y 2 43W6725 QLogic 20 port – 4Gb Fibre Channel Switch - Y Y Y Y 2 43W6724 QLogic 10 port – 4Gb Fibre Channel Switch Y Y Y Y Y 2 26R0881 QLogic 20 port – 4Gb Fibre Channel Switch - Y Y Y Y 2 32R1904 QLogic 10 port – 4Gb Fibre Channel Switch - Y Y Y Y 2 43W6723 4Gb Intelligent Pass-thru Module for IBM BladeCenter Y Y Y Y Y 2 32R1833 McData 20 port – 4Gb Fibre Channel Switch - Y Y Y Y 2 32R1905 McData 10 port – 4Gb Fibre Channel Switch - Y Y Y Y 2 39Y9280 Cisco Systems 4Gb 20 port Fibre Channel Switch Module - Y Y Y Y 3 39Y9284 Cisco Systems 4Gb 10 port Fibre Channel Switch Module Y Y Y Y Y 3 Other Modules 39Y9316 Optical Pass-through Module Y Y Y Y Y 4 39Y9320 Copper Pass-Through Module Y Y Y Y Y 1 39Y9314 Multi-switch Interconnect Module (MSIM) - - - Y - -

Note 1: Supported in left I/O Module bay of MSIM

Note 2: Supported in right I/O Module bay of MSIM

Note 3: Not supported or not applicable for use with MSIM

Note 4: OPM is supported in MSIM for Ethernet in left I/O module bay or Fibre Channel in right

I/O module bay

IBM BladeCenter Interoperability Guide

8

I/O Adapters to blade server Interoperability

P/N I/O Expansion adapters/cards or connection devices FF

H C 1 0

HS20

HS21

HS21 XM

LS20

LS21

LS41

JS20

JS21

J S 2 2

QS20

QS21

SAS

39Y9190 SAS Expansion Card (CFFv) for IBM BladeCenter See note-4 for HS20 CFFv - Y Y Y Y Y Y - Y - Y

Ethernet 73P9030 IBM Gb Expansion Card StFF - Y Y Y Y Y Y Y Y - - - 39R8624 IBM SFF Gb Expansion Card SFF - Y Y Y Y Y Y Y Y - - - 39Y9310 Ethernet Expansion Card (CFFv) CFFv - - Y Y N Y Y - Y Y - - 39Y9271 NetXen 10Gb Ethernet Expansion Card (CFFh) CFFh - - Y Y - Y Y - - - - - InfiniBand 32R1896 Cisco Systems InfiniBand HCA Expansion Card StFF - Y Y Y Y Y Y Y Y - - - 32R1760 Cisco Systems 4X InfiniBand Expansion Card HSFF - - Y Y - Y Y - Y Y - Y 43W4423 4x InfiniBand DDR Expansion Card (CFFh) CFFh - - Y Y - Y Y - - Y - - 43W4421 Cisco 4x InfiniBand DDR Expansion Card (CFFh) CFFh - - Y Y - Y Y - - - - - 43W4420 Voltaire 4x InfiniBand DDR Expansion Card (CFFh) CFFh - - Y Y - Y Y - - Y - - 42d1479 Single port IB-4x SDR Expansion Card for QS20 - - - - - - - - - - Y - Fibre 26K4841 IBM SFF Fibre Channel Expansion Card SFF - Y Y Y Y Y Y Y Y - - - 26R0884 QLogic 4Gb Standard Fibre Cannel Expansion Card StFF - Y Y Y Y Y Y Y Y - - - 26R0890 QLogic 4Gb SFF Fibre Channel Expansion Card SFF - Y Y Y Y Y Y Y Y - - - 39Y9186 Emulex 4Gb SFF Fibre Channel Expansion Card SFF - Y Y Y Y Y Y Y Y - - - 43W6859 Emulex 4Gb Fibre Channel Expansion Card (CFFv) CFFv - - Y Y - Y Y - - Y - - 41Y8527 QLogic 4Gb Fibre Channel Expansion Card (CFFv) CFFv - - Y Y - Y Y - Y - - -

39Y9306 QLogic Ethernet and 4Gb Fibre Channel Expansion Card (CFFh) CFFh - - Y Y - Y Y - Y Y - -

Myrinet 73P6000 Myrinet Cluster Expansion Card StFF - Y Y Y Y Y Y Y Y - - - Connection Device

43W6729 CP20 Workstation Connection Device3 N/A Y -

- -

-

-

-

-

-

-

-

-

iSCSI 32R1923 QLogic iSCSI Expansion Card StFF - Y Y Y Y Y Y Y Y Y - -

Notes:

Note-1 See QS20 documents for specific QS20 I/O compatibility information. StFF card on HS21 XM precludes use of hard drive bay Note-2 HC10 does not support BladeCenter I/O adapter. HC10 supports MXM Graphics adapter instead and supported graphics adapter is NVIDIA Quadro NVS 120M and NVIDIA Quadro FX1600M Note-3 Ships without a power cord. Note-4 Older models of the HS20 (8678/8832) do not support SAS switch 31Y9190

IBM BladeCenter Interoperability Guide

9

Blades & BladeBoot (iSCSI SW Boot) Compatibility Blade Servers Windows Server

2003 Windows Server

2008 SLES10 SP1 RHEL 51

HS20 (8843) Y TBD Y Y HS21 Dual Core (8853) Y TBD Y Y HS21 Quad Core (8853) Y TBD Y Y HS21 XM Dual Core (7995) Y TBD Y Y HS21 XM Quad Core (7995) Y TBD Y Y LS20 (8850) Y TBD Y Y LS21 (7971) Y TBD Y Y LS41 (7972) Y TBD Y Y JS20 (8842) - - - - JS21 (7988) - - - - HC10 (7996) - - - - QS20 (0200-250) - - - - QS21 (0792) - - - - 1RHEL 5 represents limited support, with full support targeted for RHEL 5.2

Blades NOS Compatibility

Blade Servers Windows

Server 2003

Windows Server 2003

Compute Cluster

Windows Vista

AIX 6.1 SLES10

SP1

SLES 10 for IBM Power

Solaris 10

RHEL 3 RHEL 4

RHEL 5

HC10 (7996) - - Y - - - - - - - HS20 (8843) Y - - - Y - Y Y Y Y HS21 Dual Core (8853) Y Y - - Y - Y Y Y Y

HS21 Quad Core (8853) Y Y - - Y - Y Y Y Y

HS21 XM Dual Core (7995) Y - - - Y - Y - Y Y

HS21 XM Quad Core (7995) Y - - - Y - Y - Y Y

LS20 (8850) Y - - - Y - Y Y Y Y LS21 (7971) Y Y - - Y - Y Y Y Y LS41 (7972) Y Y - - Y - Y Y Y Y JS20 (8842) - - - - - - - - - - JS21 (7988) - - - - - - - - - - JS22 (7998) - - - Y - Y - - - Y QS20 (0200-250) - - - - - - - - - - QS21 (0792) - - - - - - - - - Y

Note : See ServerProven for specific version levels.

IBM BladeCenter Interoperability Guide

10

CP20 Workstation connection Device Power Cord P/N’s by Country:

Option PN L1 PN Bulk PN Description 43W6307 39Y8284 39M4956 1.8m, 2.5A/125V, NEMA 5-15P (US/Canada) Line Cord 43W6308 39Y8281 39M4952 1.8m, 2.5A/250V, IRAM 2073 (Argentina) Line Cord 43W6309 39Y8288 39M4961 1.8m, 2.5A/250V, AS/NZS 3112 (Australia) Line Cord 43W6310 39Y8291 39M4965 1.8m, 2.5A/250V, CEE(7)-VII (Europe) Line Cord 43W6311 39Y8297 39M4973 1.8m, 2.5A/250V, SABS 164 (S.Africa) Line Cord 43W6312 39Y8300 39M4977 1.8m, 2.5A/250V, BS 1363/A (UK) Line Cord 43W6313 39Y8312 39M4993 1.8m, 2.5A/250V, JIS C-8303 (Japan) Line Cord 43W6314 39Y8315 39M4997 1.8m, 2.5A/250V, GB 2099.1 (China) Line Cord 43W6315 39Y6468 39M5001 1.8m, 2.5A/250V, KSC 8305 (Korea) Line Cord 43W6316 39Y6471 39M5005 1.8m, 2.5A/250V, IS 6538 (India) Line Cord 43W6317 39Y6474 39M5009 1.8m, 2.5A/125V, NBR 6147 (Brazil) Line Cord 43W6318 39Y5658 39M5013 1.8m, 2.5A/125V, CNS 10917-3 Taiwan Line Cord 43W6345 39Y8294 39M4969 1.8m, 2.5A/250V, DK2-5a (Denmark) Line Cord 43W6346 39Y8303 39M4981 1.8m, 2.5A/250V, 1011-S2 4507 (Switzerland) Line Cord 43W6347 39Y8306 39M4985 1.8m, 2.5A/250V, CEI 23-15 (Chile/Italy) Line Cord 43W6348 39Y8309 39M4989 1.8m, 2.5A/250V, SI 32 (Israel) Line Cord

Telco blades to Telco chassis Interoperability

NEBS-Compliant Blade Servers T NEBS1

HT NEBS1

HC10 (7996) - - HS20 (8832, 8843) Y2 Y HS21 Dual Core (8853) Up to 8 at 35W Y HS21 Quad Core (8853) Up to 8 at 50W Up to 12 at 80W HS21 XM Dual Core (7995) Up to 8 at 50W Up to 12 at 65W HS21 XM Quad Core (7995) Up to 8 at 50W Up to 12 at 80W LS20 (8850) Y2 Y LS21 (7971) Up to 8 at 45W Up to 12 at 68W LS41 (7972) Up to 4 at 68W Up to 6 at 68W JS20 (8842) Y2 Y JS21 (8844, 7988) Y2 Y JS22 (7998) - Y Notes:

Y = no restrictions on the number of blades, all blade slots may be used

Note-1 Select models – current NEBS guidance - subject to change

Note-2 NEBS testing complete and reports available

IBM BladeCenter Interoperability Guide

11

IBM BladeCenter Boot Disk System The IBM BladeCenter Boot Disk System is a way to consolidate OS initialization functions to a single, highly-redundant, 2U enclosure for one or two BladeCenter E, or H chassis.

IBM BladeCenter Boot Disk System; Chassis Compatibility

P/N Description S E T H HT

172622B IBM BladeCenter Boot Disk System - Y - Y -

IBM BladeCenter Boot Disk System; Solution Requirements

P/N Description Quantity (1 chassis)

Quantity (2 chassis)

172622B IBM BladeCenter Boot Disk System 1 1 39R6509 DS3200 SAS 2-Port Daughter Card 0 2 39Y9314 Multi-Switch Interconnect Module for IBM BladeCenter Note 2 Note 2 39Y9195 IBM BladeCenter SAS Connectivity Module 2 4 39Y9190 SAS Expansion Card (CFFv) for IBM BladeCenter 141 281 43X0802 300GB 15K 3.5" Hot-Swap SAS 6 12 40K1044 146GB 15K 3.5” Hot-Swap SAS 6 12 39R6529 39R6531

IBM 1m SAS Cable or IBM 3m SAS Cable

2 4

Notes:

Note-1 One SAS Expansion Card (CFFv) needed for support with each blade server

Note-2 If Fibre Channel or additional EN connectivity required

IBM BladeCenter Interoperability Guide

12

IBM BladeCenter Boot Disk System; Support OS Description IBM BladeCenter

Boot Disk System

Linux

Red Hat Enterprise Linux 4 AS for AMD64/EM64T Y

Red Hat Enterprise Linux 4 AS for x86 Y

Red Hat Enterprise Linux 4 ES for AMD64/EM64T Y

Red Hat Enterprise Linux 4 ES for x86 Y

SUSE LINUX Enterprise Server 9 for AMD64/EM64T Y

SUSE LINUX Enterprise Server 9 for x86 Y

SUSE LINUX Enterprise Server 10 for AMD64/EM64T Y

SUSE LINUX Enterprise Server 10 for x86 Y

Red Hat Enterprise Linux 5 ES for Power -

Microsoft

Microsoft Windows Server 2003, Web Edition Y

Microsoft Windows Server 2003/2003 R2, Datacenter Edition Y

Microsoft Windows Server 2003/2003 R2, Datacenter x64 Edition Y

Microsoft Windows Server 2003/2003 R2, Enterprise Edition Y

Microsoft Windows Server 2003/2003 R2, Enterprise x64 Edition Y

Microsoft Windows Server 2003/2003 R2, Standard Edition Y

Microsoft Windows Server 2003/2003 R2, Standard x64 Edition Y

Microsoft Windows Storage Server 2003/2003 R2, Standard Edition Y

Windows Small Business Server 2003/2003 R2 Premium Edition Y

NetWare

VMware

VMware ESX Server 2.5.4 -

VMware ESX Server 3.0.1 -

IBM Director

IBM Director v 5.20.x Y

IBM BladeCenter Interoperability Guide

13

IBM BladeCenter Open Fabric Manager1,2 Compatibility

M/T or P/N OFM (44W3981)

OFM Advanced Upgrade

(46C3551)

OFM Advanced Upgrade for IBM

Director (46C3552)

Chassis 8677 IBM BladeCenter E Y Y Y 8852 IBM BladeCenter H Y Y Y 8740/8750 BladeCenter HT Y Y Y 8886 BladeCenter S Y Y Y Blades Servers 8853 HS21 Dual Core Y Y Y 8853 HS21 Quad Core Y Y Y 7995 HS21 XM Dual Core Y Y Y 7995 HS21 XM Quad Core Y Y Y 7971 LS21 Y Y Y 7972 LS41 Y Y Y Expansion Cards and Expansion Units 26R0884 QLogic 4Gb Standard Fibre Cannel Expansion Card Y Y Y 26R0890 QLogic 4 Gb SFF Fibre Channel Expansion Card Y Y Y 39Y9186 Emulex 4 Gb SFF Fibre Channel Expansion Card Y Y Y 43W6859 Emulex 4Gb Fibre Channel Expansion Card (CFFv) Y Y Y 41Y8527 QLogic 4 Gb Fibre Channel Expansion Card (CFFv) Y Y Y

39Y9306 QLogic Ethernet and 4 Gb Fibre Channel Expansion Card (CFFh)

Y Y Y

39R8624 IBM SFF Gb Ethernet Expansion Card Y Y Y 39Y9310 Ethernet Expansion Card (CFFv) Y Y Y

Note 1: Planned Availability is December 21, 2007

Note 2: Reflects single instance compatibility. Interoperability details to be published in

February 2008.

IBM BladeCenter Interoperability Guide

14

IBM BladeCenter Boot Disk System; Configuration Diagrams

One BladeCenter H Example P/N Description Quantity 172622B IBM BladeCenter Boot Disk System 1 39Y9195 IBM BladeCenter SAS Connectivity Module 2 39Y9190 SAS Expansion Card (CFFv) for IBM BladeCenter 141 40K1044 43X0802

146GB 15K 3.5” Hot-Swap SAS or 300GB 15K 3.5" Hot-Swap SAS

12

39R6529 39R6531

IBM 1m SAS Cable or IBM 3m SAS Cable

2

Notes:

Note-1 One SAS Expansion Card (CFFv) needed for support with each blade server

IBM BladeCenter Interoperability Guide

15

IBM BladeCenter Boot Disk System; Configuration Diagrams Two BladeCenter H Example

P/N Description Quantity 172622B IBM BladeCenter Boot Disk System 1 39R6509 SAS 2-Port Daughter Card 2 39Y9195 IBM BladeCenter SAS Connectivity Module 4 39Y9190 SAS Expansion Card (CFFv) for IBM BladeCenter 281 40K1044 43X0802

146GB 15K 3.5” Hot-Swap SAS or 300GB 15K 3.5" Hot-Swap SAS

12

39R6529 39R6531

IBM 1m SAS Cable or IBM 3m SAS Cable

4

Notes:

Note-1 One SAS Expansion Card (CFFv) needed for support with each blade server

Note-2 For support with BladeCenter H only, and may be required based on number of open switch bays

IBM BladeCenter Interoperability Guide

16

Configuration Diagrams HS21, HS21 XM or LS21

LS41

IBM BladeCenter Interoperability Guide

17

LS41 continued: Note: a processor needs to be installed in the MPE to utilize the I/O capability in the MPE.

Storage I/O Expansion Unit combined with HS21, HS21 XM or LS21

IBM BladeCenter Interoperability Guide

18

Memory I/O Expansion Unit combined with HS21 (8853)

Memory I/O Expansion Unit and Storage I/O Expansion Unit combined with HS21

IBM BladeCenter Interoperability Guide

19

Storage I/O Expansion Unit and LS41

Trademarks and Disclaimers The following are trademarks of the International Business Machines Corporation in the United States and/or other countries. For a complete list of IBM Trademarks, see www.ibm.com/legal/copytrade.shtml: The following are trademarks or registered trademarks of other companies: Java and all Java based trademarks and logos are trademarks of Sun Microsystems, Inc., in the United States and other countries or both Microsoft, Windows,Windows NT and the Windows logo are registered trademarks of Microsoft Corporation in the United States, other countries, or both. Intel, Intel logo, Intel Inside, Intel Inside logo, Intel Centrino, Intel Centrino logo, Celeron, Intel Xeon, Intel SpeedStep, Itanium, and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. UNIX is a registered trademark of The Open Group in the United States and other countries or both. Linux is a trademark of Linus Torvalds in the United States, other countries, or both. Other company, product, or service names may be trademarks or service marks of others. NOTES: Any performance data contained in this document was determined in a controlled environment. Actual results may vary significantly and are dependent on many factors including system hardware configuration and software design and configuration. Some measurements quoted in this document may have been made on development-level systems. There is no guarantee these measurements will be the same on generally-available systems. Users of this document should verify the applicable data for their specific environment. IBM hardware products are manufactured from new parts, or new and serviceable used parts. Regardless, our warranty terms apply. Information is provided “AS IS” without warranty of any kind. All customer examples cited or described in this presentation are presented as illustrations of the manner in which some customers have used IBM products and the results they may have achieved. Actual environmental costs and performance characteristics will vary depending on individual customer configurations and conditions.

IBM BladeCenter Interoperability Guide

20

This publication was produced in the United States. IBM may not offer the products, services or features discussed in this document in other countries, and the information may be subject to change without notice. Consult your local IBM business contact for information on the product or services available in your area. All statements regarding IBM's future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only. Information about non-IBM products is obtained from the manufacturers of those products or their published announcements. IBM has not tested those products and cannot confirm the performance, compatibility, or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products. Prices are suggested US list prices and are subject to change without notice. Starting price may not include a hard drive, operating system or other features. Contact your IBM representative or Business Partner for the most current pricing in your geography. Any proposed use of claims in this presentation outside of the United States must be reviewed by local IBM country counsel prior to such use. The information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. Any references in this information to non-IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk. IBM makes no representation or warranty regarding third-party products or services including those designated as ServerProven, ClusterProven or BladeCenter Interoperability Program products. Support for these third-party (non-IBM) products is provided by non-IBM Manufacturers. IBM may have patents or pending patent applications covering subject matter in this document. The furnishing of this document does not give you any license to these patents. Send license inquires, in writing, to IBM Director of Licensing, IBM Corporation, New Castle Drive, Armonk, NY 10504-1785 USA.