bleeker digital catalog

76
COMPANY INFO SELECTING YOUR BOOTH FLOOR FILTER BOOTHS BENCH FILTER BOOTHS SPECIAL APPLICATION BOOTHS VARSOL FILTER BOOTHS POWDER CONTAINMENT BOOTHS POWDER CONTAINMENT BENCH BOOTHS BATCH TYPE & PRODUCTION TYPE AUTO & VAN FILTER CROSSDRAFT AUTO FILTER BOOTHS VAN FILTER BOOTHS AUTO-TRUCK & TRUCK FILTER BOOTH TRUE DOWN-DRAFT BOOTHS SEMI-DOWN DRAFT BOOTHS EXHAUST PLENUMS POWDER CONTAINMENT EXHAUST PLENUMS RECIRCULATING HEAT SYSTEMS FLASH-OFF ENCLOSURES BLEEKER CURE™ INFRA-RED AIR MAKE-UP UNITS TYPICAL AIR SUPPLY ARRANGEMENTS CUSTOM DOWNDRAFT GRINDING ENCLOSURE BENCH WATER-WASH BOOTHS PUMP WATER-WASH BOOTHS SLUDGE REMOVAL CENTRIFUGE PAINT MIX ROOMS FINAL FILTER FRAMES BOOTH DOORS BOOTH COMPONENTS BOOTH ACCESSORIES EXHAUST DUCT COMPONENTS VELOCITY CONE & MUFFLERS ELECTRIC MOTORS BOOTH FILTERS TUBEAXIAL EXHAUST FANS BOOTH HARDWARE ELBOW & OFFSET DUCT SPECS EXHAUST STACK ELECTRICAL CODES INDEX BLEEKER DIGITAL CATALOG TABLE OF CONTENT (select) HOW TO USE THIS CATALOG 1. Touch on any TABLE OF CONTENT item to take view to that page. 2. Use Acrobat first page tool to return to Table of Content. TO VIEW PAGE DETAIL Use Acrobat magnification tool to see small text in charts & drawings. TO PRINT Select Acrobat File>Print HELP Select Acrobat Help for application details GO TO... www.BleekerBros.com

Upload: others

Post on 21-Oct-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BLEEKER DIGITAL CATALOG

COMPANY INFOSELECTING YOUR BOOTHFLOOR FILTER BOOTHSBENCH FILTER BOOTHSSPECIAL APPLICATION BOOTHSVARSOL FILTER BOOTHSPOWDER CONTAINMENT BOOTHSPOWDER CONTAINMENT BENCH

BOOTHSBATCH TYPE & PRODUCTION TYPEAUTO & VAN FILTER CROSSDRAFTAUTO FILTER BOOTHSVAN FILTER BOOTHSAUTO-TRUCK & TRUCK FILTER

BOOTHTRUE DOWN-DRAFT BOOTHS

SEMI-DOWN DRAFT BOOTHSEXHAUST PLENUMSPOWDER CONTAINMENT EXHAUST

PLENUMSRECIRCULATING HEAT SYSTEMSFLASH-OFF ENCLOSURESBLEEKER CURE™ INFRA-REDAIR MAKE-UP UNITSTYPICAL AIR SUPPLY

ARRANGEMENTSCUSTOM DOWNDRAFT GRINDING

ENCLOSUREBENCH WATER-WASH BOOTHSPUMP WATER-WASH BOOTHSSLUDGE REMOVAL CENTRIFUGEPAINT MIX ROOMS

FINAL FILTER FRAMESBOOTH DOORSBOOTH COMPONENTSBOOTH ACCESSORIESEXHAUST DUCT COMPONENTSVELOCITY CONE & MUFFLERSELECTRIC MOTORSBOOTH FILTERSTUBEAXIAL EXHAUST FANSBOOTH HARDWAREELBOW & OFFSET DUCT SPECSEXHAUST STACKELECTRICAL CODESINDEX

BLEEKER DIGITAL CATALOG

TABLE OF CONTENT (select)

HOW TO USE THIS CATALOG1. Touch on any TABLE OF CONTENT itemto take view to that page.

2. Use Acrobat first page toolto return to Table of Content.

TO VIEW PAGE DETAILUse Acrobat magnification toolto see small text in charts &drawings.

TO PRINTSelect Acrobat File>Print

HELP Select Acrobat Help for application details

GO TO... www.BleekerBros.com

Page 2: BLEEKER DIGITAL CATALOG

Toll Free 800.421.1107 1

BLE

EK

ER

www.BleekerBros.com

Over 50 years of manufacturing experience.

Extensive choice of standard paint booths andrelated equipment availablefor fast delivery.

Customized booths andsystems can also be readilymanufactured to meetspecialized needs.

Experienced engineering team is available to help make theproper and best equipmentchoice.

Bleeker Bros., Inc. canfulfill your finishingequipment requirements,from a standard to customdesign, from a small paintbooth to a completeturnkey system.

ExpertTechnicalSupport

CONTENTSManufacturers ofQuality SprayBooths SELECTING YOUR BOOTH 2

FLOOR FILTER BOOTHS 6

BENCH FILTER BOOTHS 10

SPECIAL APPLICATION BOOTHS 11

VARSOL FILTER BOOTHS 12

POWDER CONTAINMENT BOOTHS 14

POWDER CONTAINMENT BENCH BOOTHS 16

BATCH TYPE & PRODUCTION TYPE 18

AUTO & VAN FILTER CROSSDRAFT 20

AUTO FILTER BOOTHS 22

VAN FILTER BOOTHS 23

AUTO-TRUCK & TRUCK FILTER BOOTH 24

TRUE DOWN-DRAFT BOOTHS 28

SEMI-DOWN DRAFT BOOTHS 30

EXHAUST PLENUMS 32

POWDER CONTAINMENT EXHAUST PLENUMS 34

RECIRCULATING HEAT SYSTEMS 35

FLASH-OFF ENCLOSURES 36

BLEEKER CURE™ INFRA-RED 38

AIR MAKE-UP UNITS 40

TYPICAL AIR SUPPLY ARRANGEMENTS 42

CUSTOM DOWNDRAFT GRINDING ENCLOSURE 43

BENCH WATER-WASH BOOTHS 44

PUMP WATER-WASH BOOTHS 46

PUMPLESS WATER-WASH BOOTHS 48

SLUDGE REMOVAL CENTRIFUGE 51

PAINT MIX ROOMS 52

FINAL FILTER FRAMES 53

BOOTH DOORS 54

BOOTH COMPONENTS 55

BOOTH ACCESSORIES 60

EXHAUST DUCT COMPONENTS 62

VELOCITY CONE & MUFFLERS 64

ELECTRIC MOTORS 65

BOOTH FILTERS 66

TUBEAXIAL EXHAUST FANS 68

BOOTH HARDWARE 70

ELBOW & OFFSET DUCT SPECS 71

EXHAUST STACK 72

ELECTRICAL CODES 73

INDEX 74

California USA ©1999 Bleeker Bros.All rights reserved.

Bleeker Bros., Inc. 10868 Drury LaneLynwood• CA • 90262

800/421-1107310/639-4367FAX 310/639-4106

Stability...Reliability...Quality!

Page 3: BLEEKER DIGITAL CATALOG

2 EMAIL: [email protected] www.BleekerBros.com

BLE

EK

ER

EXHAUST PLENUMS are similarto Filter booths, but without theworking depth. They are utilizedwhen the user has an existingworking area or room availableinto which he wants an exhaustsystem installed.

AUTOMOTIVE-TYPE BOOTHS,including AUTOMOTIVE, VAN,TRUCK, and AUTO-TRUCKbooths are generally used forvehicular-type equipment. Theyare available in drive-in or drive-through style and are noted forsupplying clean air and for goodlighting. Can beCROSSDRAFT,DOWNDRAFT, or SEMI-DOWNDRAFT air flow style.All booths of these types canalso be supplied with infraredheaters for increased production.Heated air make-up isrecommended in cold climates.

BENCH WATER-WASHBOOTHS utilize downdraftfeatures. The most commonusage utilizes water filtrationwhich allows grinding of metallicmaterial. Material or paintpigments are pulled into thewater tank.

PUMP WATER-WASH BOOTHSare often chosen when there isheavy painting or pigmentoverspray. Allows continuousoperation with minimum of downtime for maintenance. Whenextremely high paint pigmentaccumulation in tank occurs, it isrecommended that a sludgeremoval system be integratedinto the booth, allowing for amore continuous paint operation,while saving on sludge removaland disposal costs.

PUMPLESS WATER-WASHBOOTHS have the generaladvantages of and are similar toPump Water-Wash booths,however these booths are notrecommended under very highpaint volume conditions. Thistype is an absolute must for hotmetal spray applications.

SELECTING YOUR SPRAY BOOTH

STANDARD FLOOR FILTER BOOTHSare the most common of all boothtypes. Used for moderate industrialpainting that does not require highgloss finish. If dusty conditionsprevail in the area, all BLEEKERBROS. open-faced booths can beordered or retrofitted with filtered frontdoors to enhance the quality of thefinished product.

BENCH BOOTHS are similar to FloorFilter booths but are used whensmaller items, such as toys, are to becoated.

VARSOL BENCH BOOTHS are usedstrictly for cleaning or degreasingsmall items.

POWDER CONTAINMENT BOOTHSare used for spraying powder and/orgrinding non-metallic (fiberglass, etc,)items. This equipment is for lowvolume usage. Exhaust air can berecirculated back into the factory,thereby eliminating the need for roofpenetration and/or air replacement.Because of environmental restrictions,this type of booth has become a verypopular alternative to inexpensivelyenter into the powder coatingindustry.

CARTRIDGE BATCH & PRODUCTIONPOWDER BOOTHS are used wherehigh production powder or non-metallic grinding applications arerequired.

SELECTING YOUR PAINTINGEQUIPMENT

The need to invest in painting equipment is governed by thefollowing requirements:

• Producing a finer product

• Protecting your employees

• Protecting the environment

• The need to meet all federal and local codes regulating the painting industry

TYPES OF SPRAY BOOTHS

Page 4: BLEEKER DIGITAL CATALOG

Toll Free 800.421.1107 3

BLE

EK

ER

BLE

EK

ER

SELECTING YOUR SPRAY BOOTH

SPECIAL APPLICATION FILTERS are also available forspecific uses:

• CHROMATE SYSTEM is a three-stage filtering systemfor highly toxic chromate painting.

• CARBON ABSORPTION (CHARCOAL) SYSTEM is a three-stage system for paint pigment and VOC capture.

DRY PAINT (POWDER) AND GRINDING FILTERS

DRY PAINT (POWDER) AND GRINDING is the othertype of exhaust filter and should be used as a three-stage system for maximum efficiency.

The four most common filters of this type are:

• PRE-FILTERS, sized 20” x 20” X 1”, catch heavy particles.

• POCKET FILTERS, 20” X 20” X 12”, also known as “bag filters”, catch smaller particles and have greater holding capacity.

• FINAL FILTERS, 24” X 24” X 12”, ( 95% efficiency) arethe last filters prior to entering the room, before the airenters the working environment.

(NOTE: The above filters are most effective when used together as a three-stage filtration system.)

• CARTRIDGE FILTERS are used in high production applications.

AIR INTAKEFILTERS

AIR INTAKE FILTERSclean incoming air. Theirpurpose is to maintain arelatively dust freepainting condition toimprove the quality of thefinished product.

The type of air intakefilters for your needs willdepend upon the degreeof dust free environmentthat is required.

Sizes vary depending on requirements.

Other filter types and sizes may be special ordered.Contact factory or dealer for information and prices.

Other related equipment is available and may be supplied.Special requirements or booth configurations can beintegrated into your booth design for a customizedsystem. Call BLEEKER BROS. for additional informationabout these and other related equipment:

• CONVEYOR OPENINGS

• RECIRCULATION ENCLOSURES

• AIR MAKE-UP UNITS

• INFRARED HEATERS

• SLUDGE REMOVAL SYSTEMS

• SPECIAL LIGHTING

• ELECTRICAL CONTROLS

• NOISE REDUCTION

• PAINT MIX ROOMS

• POLLUTION CONTROL (VOC ABATEMENT)

• DRYING ENCLOSURES

THINGS TO CONSIDER WHENORDERING YOUR SPRAY BOOTH

EXHAUST FILTERS

DRY EXHAUST FILTERS

Dry Exhaust Filters to clean outgoing air are required toprotect the environment. Paint arrestor type filters areused for wet painting operations.

The three most common types of dry exhaust filters are:

• PAINT ARRESTOR PAPER FILTERS are a very popularand inexpensive filter. Sizes include 20” x 20” andcan be changed one at a time, as required.

• ROLL MEDIA, 45” X 30’, is recommended when frequent changes are necessary. Labor savings due to quickness of change.

• FIBERGLASS FILTERS, size 20” X 20”, are recommended for some types of painting or grinding applications.

(NOTE: The above types of filters generally are interchangeable in the capture of paint pigments. However, depending on specific application, one type may be more suitable than another. Contact our Engineering Dept. or a knowledgeable dealer of spray booth equipment to discuss your special needs.)

Pocket Filter

Cartridge Filter

Page 5: BLEEKER DIGITAL CATALOG

4 EMAIL: [email protected] www.BleekerBros.com

BLE

EK

ER

SELECTING YOUR SPRAY BOOTH

LIGHTING

LIGHTING is totally subjective. Your lighting needsshould be based on:

• Type of application – conveyorized or manual

• Type of material to be coated

• Size of area to be illuminated

BLEEKERBROS. fluorescent light fixturesincorporate the latest energysaving electronic ballast and carry UL and C-UL approval.

If true color is to be observed, it may be necessary topurchase special tubes for fluorescent fixtures in order tosee the true color.

The quantity and placement of BLEEKER BROS. lightingfixtures have been proven over the years to be highlysuccessful for the majority of painting requirements.However, fluorescent lighting is a high cost item.Adding or deducting the quantities of light fixtures caneasily be made to BLEEKER booth arrangements.

AIR MOVEMENT

Movement of airthrough a booth isspecified by theUniform Fire Code(UFC). For example,the minimum for mostbooths is 100 fpm.Bench booths require aminimum of 150 fpm.However, sometimes it isrecommended to have higher or lower movement throughcertain booths, such as downdraft, automotive,electrostatic and powder booths. Proper air movementsuitable for your specific needs should be discussed withour Engineering Department or an experienced dealer ofpaint spray booths.

CROSS-DRAFT AIR MOVEMENT (CFM), is figured bymultiplying the inside width x the inside height of a booth xthe amount of air movement that is needed or desired. Theworking depth (front to back) is not a consideration.

For example: A booth 8’W x 8’H=64 sq.ft. Multiply 64’ x theamount of air movement (face velocity) desired.

64’ x 100’(face velocity)=6400 C.F.M. (cubic feet per minute)

64’ x 150’(face velocity)=9600 C.F.M. (cubic feet per minute)

STATIC PRESSURE is the resistance a blower or fan mustovercome to reach a desired C.F.M. Factors affectingresistance in a spray booth include:

• Type of filter used, (if clean or dirty)

• Water wash style (contact manufacturer)

• Size of duct in relationship to air velocity

• Length of duct

• Number of offsets or any other obstructions

NOISE REDUCTION

Meeting OSHA requirementsor the requirements of yourparticular painting area for anacceptable comfort level foryour employees may requirethe additional purchase of adecibel reducer (muffler) for your paint exhaust blower.Things to consider include:

• Noise level (decibels) before installation of new equipment

• Noise level (decibels) after installation of new equipment

• Reduction of noise level desired

MAKING CHOICES

BOOTH SIZE

• The largest part of the product to be coated should be 2 to 3 feet from exhaust filters and booth front on open face styles. Sides and closed front should be atleast 3 to 4 feet away allowing the painting operator room to maneuver with adequate room to paint.

• CONVEYOR OPENING: To best contain overspray, it isrecommended to provide room to include a minimum of a one foot vestibule, more if possible.

• Choosing a WATER WASH BOOTH over a FILTER STYLE BOOTH should involve your paint supplier to make the proper decision.

ITEMS TO CONSIDER FOR FILTERBOOTHS

• Labor and down time cost to change filters.

• Frequency of changes required per month

• Filter costs per year

• Filter disposal regulations and costs

• Initial cost savings

VT Light Fixture

Muffler

Tube Axial Fan

Page 6: BLEEKER DIGITAL CATALOG

Toll Free 800.421.1107 5

BLE

EK

ER

SELECTING YOUR SPRAY BOOTH

CROSS FLOW AIR MOVEMENT• Air moves from one end to the other.• Most popular in smaller sized booths.• Can easily be installed and/or moved.• If the part is long and the air movement passes from

one end to the other, care must be taken to prevent overspray.

DOWNDRAFT AIR MOVEMENT• Air moves from top to bottom, carrying any overspray

downward; assisting the natural flow of pigment layered air.

• This design, with its downward flow of air, can easily accommodate more than one operator.

• Used with a separate air supply (either heated or ambient.)

TRUE DOWNDRAFT BOOTHThe true downdraft booth incorporates a pit below thefloor line with proper grating, or a basement plenum abovethe floor line with proper grating and access ramp. Thebelow floor line arrangement eliminates theability to easily change the workflowlayout.

SEMI DOWNDRAFTBOOTHThe semidowndraft boothcan be acomfortablecompromise totake advantage ofthe downdraftdesign, withoutrequiring a pit below the floor line.

NOTE:

In order to obtain all of the benefits of a down draftprinciple, the booth should be pressurized with an airsupply unit to maintain a dust free environment.

With the downdraft air flow and the floor area of anautomotive booth being much larger than the crosssection of the same booth, a larger air supply unit isrequired to maintain the same velocities, which results inhigher air exchange, better ventilation, and cleanerfinishes, compared to a cross draft booth. However,excellent results are being obtained at lower velocities,as used in the automotive industry, conserving resourcesand making it the preferred choice of automotive re-finishers.

All equipment offered in this catalog is designed forindoor installation. Contact factory for SpecialOutdoor Spray Booths if required.

ITEMS TO CONSIDER FOR WATERWASH BOOTHS

• Extra effort and cost to maintain water neutrality

• Extra electrical costs for additional power

• Down time for cleaning

• Extra cost for panel replacement. A well maintained booth should last for many years, but water can eventually deteriorate panels.

• Disposal cost of contaminated water

• The need to include a sludge removal system to decrease down time for booth maintenance and lowering the cost of hazardous waste disposal.

• The initial cost of a water wash system over a filter booth and future maintenance.

HEATED AIR MAKE-UP UNITS

HEATING AND SUPPLYING INDIVIDUAL SPRAYBOOTHS is most effective in maintaining a dust freepositive booth air flow. An individual filtered intake plenumis built intothe booth,keeping itcompletelyindependent ofoutside conditions, bothfor temperature andatmosphere. One heated airsupply unit can service more thanone paint spray booth.

FLASH-OFF/DRYING ENCLOSURES

These may be ordered with or without heat. They can bebuilt independently or attached to an existing spray boothsetup. The enclosure could utilize air movementonly or incorporate infrared heaters or anindirect recirculating gas heater toprovide elevated dryingtemperatures.

The decision inchoosing betweenan infrared systemor raising theambienttemperature with arecirculating gasheater to speed upcuring or dryingtime must be carefully thought out. Our BLEEKER-CUREsystem is our own design utilizing infrared equipment. Theinfrared system is by far the fastest but is affected directlyby the type of material being coated, the density andshape of the product, and the variety and quantity ofproducts being coated per day. It is best to consult withan experienced dealer when making this decision.

True Down Draft Booth

Page 7: BLEEKER DIGITAL CATALOG

6 EMAIL: [email protected] www.BleekerBros.com

BLE

EK

ER

FLOOR FILTER BOOTHS

for forklift handling.

• Fans, motors, filters, etc., are packaged but loose.

• Shipment by Public Carrier has special requirements. Contact Factory or Dealer.

Additional Features Available• Conveyor openings

• Explosion-proof motors

• Working depth extensions

• Special width or height requirements

• Special lighting arrangements

• Contact factory or dealer for priceadjustment.

Construction Features• 18-gauge galvanized steel panels.

• Bolt construction. Inside of booth is smooth.

• Filter cells are 20” X 20” X 3”.

• Light windows contain 1/4” clear tempered glass.

• Fans are belt driven, with enclosed belt guards.

• Blades are rigid-type, spark-resistant and di-electric.

• Spray booth panels rest on heavy duty 14 gauge, galvanized floor angles.

• Face velocity exceeds code requirement of 100 F. P. M.

• See specifications for face velocity of individual booths.

GENERAL INFORMATION

Typical Open-Type Fluorescent Lighting for

Booths with 10’ Working Depth and greater

Typical Vapor-Tight Fluorescent Lighting for

Booths with Working Depth of less than 10’

BOOTH PACKAGE

Includes:Fan & Motor

Exhaust Filters

Solenoid Valve

Nuts & Bolts

Manometer

Light Fixtures

Assembly Instructions

Not Included:Tubes or Bulbs

Duct Package

Sprinkler Systems

Air Lines

Electrical Switches

Motor Starter

Attachment anchors fromBooth to Floor

Electrical Hook-Up

NOTES

Lighting quantity is very subjective.Adding or deducting the quantitiesof light fixtures can easily be madeto our booth arrangements withoutlosing the financial advantage ofpurchasing a packaged booth.

Floor filter booths exceeds U.F.C.requirement of 100 feet per minuteface velocity by at least 20%.

Booth dimensions and price aresubject to change without notice.

Features• All Floor Filter Paint Spray

Booths adhere to the Uniform Fire Code and the National Electrical Code. Always check local fire and electrical codes for special conditions that may prevail in your area.

• Open-Type (O.T.) Fluorescent Light Fixtures as listed are U.L. and C-U.L. approved, 4’ long, 4-tubes.

• Vapor-Tight (V.T.) Fluorescent Fixtures as listed are U.L. and C-U.L. approved, 4’-long, 4 tubes, adhering to Hazardous Area Class 1, Division 2 from the National Electrical Code.

• All Light Fixtures are placed on the outside of 1/4” Clear Tempered Glass, gasketed and locked in place in the working depth of the Booth.

• Fan Motors are 3-phase, 208/230/460 volt, 60 Hz.

• Light Fixtures are 120 volt.

• Solenoid Valve is single phase. Voltage must be stated (110/220 etc.).

• Fan Outlet: top is standard. Backor side outlet can be supplied butposition must be requested.

• H.V. after model number, signifieshigher Face Velocity for that model. All other models that have no alternate H.V. units can increase their Face Velocity at a minimum expense by increasing listed horsepower and pulley diameter.

• Panels are skidded and banded

Page 8: BLEEKER DIGITAL CATALOG

Toll Free 800.421.1107 7

BLE

EK

ER

BLE

EK

ER

FLOOR FILTER BOOTHS

A

B

C D

PF-4-7-5 4'-0" 6'-10" 5'-0" 2'-0" 8 1-VT-FLUR 4'-4" 7' 0" 7'-2" 1-18" 3/4 3,635 130 800

PF-4-7-7 4'-0" 6'-10" 7'-0" 2'-0" 8 1-VT-FLUR 4'-4" 7'-0" 9'-2" 1-18" 3/4 3,635 130 900

PF-4-8-5 4'-0" 7'-10" 5'-0" 2'-0" 8 1-VT-FLUR 4'-4" 8'-0" 7'-2" 1-18" 1 4,290 135 900

PF-4-8-7 4'-0" 7'-10" 7'-0" 2'-0" 8 1-VT-FLUR 4'-4" 8'-0" 9'-2" 1-18" 1 4,290 135 1,000

PF-4-10-5 4'-0" 9'-10" 5'-0" 2'-6" 10 1-VT-FLUR 4'-4" 10'-0" 7'-8" 1-24" 1 6,260 155 1,100

PF-4-10-7 4'-0" 9'-10" 7'-0" 2'-6" 10 1-VT-FLUR 4'-4" 10'-0" 9'-8" 1-24" 1 6,260 155 1,150

PF-5-7-5 5'-0" 6'-10" 5'-0" 2'-6" 12 1-VT- FLUR 5'-4" 7'-0" 7'-8" 1-24" 1 6,260 175 900

PF-5-7-7 5'-0" 6'-10" 7'-0" 2'-6" 12 1-VT- FLUR 5'-4" 7'-0" 9'-8" 1-24" 1 6,260 175 1,000

PF-5-8-5 5'-0" 7'-10" 5'-0" 2'-6" 12 1-VT- FLUR 5'-4" 8'-0" 7'-8" 1-24" 1 6,260 155 1,000

PF-5-8-7 5'-0" 7'-10" 7'-0" 2'-6" 12 1-VT- FLUR 5'-4" 8'-0" 9'-8" 1-24" 1 6,260 155 1,100

PF-5-10-5 5'-0" 9'-10" 5'-0" 2'-6" 15 1-VT- FLUR 5'-4" 10'-0" 7'-8" 1-24" 1 6,260 125 1,200

PF-5-10-7 5'-0" 9'-10" 7'-0" 2'-6" 15 1-VT- FLUR 5'-4" 10'-0" 9'-8" 1-24" 1 6,260 125 1,250

PF-6-7-5 6'-0" 6'-10" 5'-0" 2'-6" 12 1-VT- FLUR 6'-4" 7'-0" 7'-8" 1-24" 1 6,260 150 1,000

PF-6-7-7 6'-0" 6'-10" 7'-0" 2'-6" 12 1-VT- FLUR 6'-4" 7'-0" 9'-8' 1-24" 1 6,260 150 1,100

PF-6-8-5 6'-0" 7'-10" 5'-0" 2'-6" 12 1-VT- FLUR 6'-4" 8'-0" 7'-8" 1-24" 1 6,260 130 1,050

PF-6-8-7 6'-0" 7'-10" 7'-0" 2'-6" 12 1-VT- FLUR 6'-4" 8'-0" 9'-8" 1-24" 1 6,260 130 1,160

PF-6-10-5 6'-0" 9'-10" 5'-0" 2'-6" 15 1-VT- FLUR 6'-4" 10'-0" 7'-8" 1-24" 1 1/2 7,200 120 1,300

PF-6-10-7 6'-0" 9'-10" 7'-0" 2'-6" 15 1-VT- FLUR 6'-4" 10'-0" 9'-8" 1-24" 1 1/2 7,200 120 1,350

PF-8-7-5 8'-0" 6'-10" 5'-0" 2'-6" 16 1-VT- FLUR 8'-4" 7'-4" 7'-8" 1-24" 1 1/2 7,200 125 1,075

PF-8-7-7 8'-0" 6'-10" 7'-0" 2'-6" 16 1-VT- FLUR 8'-4" 7'-4" 9'-8" 1-24" 1 1/2 7,200 125 1,185

PF-8-8-5 8'-0" 7'-10" 5'-0" 2'-6" 16 1-VT- FLUR 8'-4" 8'-4" 7'-8" 1-24" 2 8,500 130 1,175

PF-8-8-7 8'-0" 7'-10" 7'-0" 2'-6" 16 1-VT- FLUR 8'-4" 8'-4" 9'-8" 1-24" 2 8,500 130 1,275

PF-8-10-5 8'-0" 9'-10" 5'-0" 3'-0" 20 1-VT-FLUR 8'-4" 10'-4" 8'-2" 1-30' 1 1/2 9,815 120 1,400

PF-8-10-7 8'-0" 9'-10" 7'-0" 3'-0" 20 2-VT-FLUR 8'-4" 10'-4" 10'-2" 1-30" 1 1/2 9,815 120 1,450

PF-10-7-7 10'-0" 6'-10" 7'-0" 2'-6" 20 2-VT-FLUR 10'-4" 7'-4" 9'-8" 1-24" 2 8,580 120 1,550

PF-10-7-10 10'-0" 6'-10" 10'-0" 2'-6" 20 2-OT-FLUR 10'-4" 7'-4" 12'-8" 1-24" 2 8,580 120 1,730

PF-10-8-7 10'-0" 7'-10" 7'-0" 3'-0" 20 2-VT-FLUR 10'-4" 8'-4" 10'-2" 1-30" 1 1/2 9,815 120 1,650

PF-10-8-10 10'-0" 7'-10" 10'-0" 3'-0" 20 2-OT-FLUR 10'-4" 8'-4" 13'-2" 1-30" 1 1/2 9,815 120 1,840

PF-10-10-7 10'-0" 9'-10" 7'-0" 3'-0" 25 2-VT-FLUR 10'-4" 10'-4" 10'-2" 1-30" 3 13,180 130 1,900

PF-10-10-10 10'-0" 9'-10" 10'-0" 3'-0" 25 3-OT-FLUR 10'-4" 10'-4" 13'-2" 1-30" 3 13,180 130 2,125

PF-10-12-7 10'-0" 11'-10" 7'-0" 3'-0" 30 2-VT-FLUR 10'-4" 12'-4" 10'-2" 1-30" 5 15,785 130 2,150

PF-10-12-10 10'-0" 11'-10" 10'-0" 3'-0" 30 3-OT- FLUR 10'-4" 12'-4" 13'-2" 1-30" 5 15,785 130 2,400

PF-12-7-7 12'-0" 6'-10" 7'-0" 3'-0" 28 2-VT- FLUR 12'-4" 7'-4" 10'-2" 1-30" 2 11,180 130 1,800

PF-12-7-10 12'-0" 6'-10" 10'-0" 3'-0" 28 3-OT-FLUR 12'-4" 7'-4" 13'-2" 1-30" 2 11,180 130 2,000

PF-12-8-7 12'-0" 7'-10" 7'-0" 3'-0" 28 2-VT- FLUR 12'-4" 8'-4" 10'-2" 1-30" 3 13,180 135 2,000

PF-12-8-10 12'-0" 7'-10" 10'-0" 3'-0" 28 3-OT-FLUR 12'-4" 8'-4" 13'-2" 1-30" 3 13,180 135 2,210

PF-12-10-7 12'-0" 9'-10" 7'-0" 3'-0" 35 3-VT- FLUR 12'-4" 10'-4" 10'-2" 1-30" 5 15,785 130 2,300

PF-12-10-10 12'-0" 9'-10" 10'-0" 3'-0" 35 3-OT-FLUR 12'-4" 10'-4" 13'-2" 1-30" 5 15,785 130 2,540

PF-12-12-7 12'-0" 11'-10" 7'-0" 3'-6" 42 3-VT-FLUR 12'-4" 12'-4" 10'-8" 1-34" 5 18,280 125 2,650

PF-12-12-10 12'-0" 11'-10" 10'-0" 3'-6" 42 4-0T-FLUR 12'-4" 12'-4" 13'-8" 1-34" 5 18,280 125 2,920

MODEL WIDTH HEIGHT WORKING PLENUM FILTER FLUOR. LIGHTS WIDTH HEIGHT DEPTH EXHAUST MOTOR C. F. M @ FACE SHIPPING NO. I. D I. D. DEPTH DEPTH CELLS NO. & TYPE OVERALL OVERALL OVERALL FAN H. P. 1/4" S. P. VELOCITY WEIGHT

(A) (B) (C) (D) 20X20X3 AVERAGE

©1999 BLEEKER BROS.

Page 9: BLEEKER DIGITAL CATALOG

8 EMAIL: [email protected] www.BleekerBros.com

BLE

EK

ER

FLOOR FILTER BOOTHS

PF-14-7-7 14'-0" 6'-10" 7'-0" 3'-0" 32 3-VT-FLUR 15'-0" 7'-6" 10'-2" 1-30" 3 13,180 130 2,050

PF-14-7-10 14'-0" 6'-10" 10'-0" 3'-0" 32 4-OT-FLUR 15'-0" 7'-6" 13'-2" 1-30" 3 13,180 130 2,260

PF-14-8-7 14'-0" 7'-10" 7'-0" 3'-0" 32 3-VT-FLUR 15'-0" 8'-6" 10'-2" 1-30" 5 15,785 140 2,150

PF-14-8-10 14'-0" 7'-10" 10'-0" 3'-0" 32 4-OT-FLUR 15'-0" 8'-6" 13'-2" 1-30" 5 15,785 140 2,375

PF-14-10-7 14'-0" 9'-10" 7'-0" 3'-6" 40 3-VT- FLUR 15'-0" 10'-6" 10'-8" 1-34" 5 18,280 130 2,450

PF-14-10-10 14'-0" 9'-10" 10'-0" 3'-6" 40 4-OT-FLUR 15'-0" 10'-6" 13'-8" 1-34" 5 18,280 130 2,700

PF-14-12-7 14'-0" 11'-10" 7'-0" 4"-0" 48 3-VT-FLUR 15'-0" 12'-6" 11'-2" 1-42" 5 23,505 135 2,900

PF-14-12-7HV 14'-0" 11'-10" 7'-0" 3'-0" 48 3-VT-FLUR 15'-0" 12'-6" 10'-2" 2-30" 3 26,360 155 3,000

PF-14-12-10 14'-0" 11'-10" 10'-0" 4'-0" 48 4-OT-FLUR 15'-0" 12'-6" 14'-2" 1-42" 5 23,505 135 3,180

PF-14-12-10HV 14'-0" 11'-10" 10'-0" 3'-0" 48 4-OT-FLUR 15'-0" 12'-6" 13'-2" 2-30" 3 26,360 155 3,280

PF-16-7-7 16'-0" 6'-10" 7'-0" 3'-0" 36 3-VT-FLUR 17'-0" 7'-6" 10'-2" 1-30" 5 15,785 140 2,200

PF-16-7-10 16'-0' 6'-10" 10'-0" 3'-0" 36 3-OT-FLUR 17'-0" 7'-6" 13'-2" 1-30" 5 15,785 140 2,425

PF-16-8-7 16'-0" 7'-10" 7'-0" 3'-6" 36 3-VT-FLUR 17'-0" 8'-6" 10'-8" 1-34" 3 15,350 120 2,350

PF-16-8-10 16'-0" 7'-10" 10'-0" 3'-6" 36 4-OT-FLUR 17'-0" 8'-6" 13'-8" 1-34" 3 15,350 120 2,590

PF-16-10-7 16'-0" 9'-10" 7'-0" 4'-0" 45 4-VT-FLUR 17'-0" 10'-6" 11'-2" 1-42" 5 23,505 145 2,975

PF-16-10-10 16'-0" 9'-10" 10'-0" 4'-0" 45 5-OT-FLUR 17'-0" 10'-6" 14'-2" 1-42" 5 23,505 145 3,245

PF-16-12-7 16'-0" 11'-10" 7'-0" 4'-0" 54 4-VT-FLUR 17'-0" 12'-6" 11'-2" 1-42" 5 23,505 120 3,300

PF-16-12-7HV 16'-0" 11'-10" 7'-0" 3'-0" 54 4-VT-FLUR 17'-0" 12'-6" 10'-2" 2-30" 3 26,360 135 3,400

PF-16-12-10 16'-0" 11'-10" 10'-0" 4'-0" 54 5-OT-FLUR 17'-0" 12'-6" 14'-2" 1-42" 5 23,505 120 3,700

PF-16-12-10HV 16'-0" 11'-10" 10'-0" 3'-0" 54 5-OT-FLUR 17'-0" 12'-6" 13'-2" 2-30" 3 26,360 135 3,800

PF-18-7-7 18'-0" 6'-10" 7'-0" 3'-6" 40 4-VT-FLUR 19'-0" 7'-6" 10'-8" 1-34" 3 15,350 120 2,350

PF-18-7-10 18'-0" 6'-10" 10'-0" 3'-6" 40 4-OT-FLUR 19'-0" 7'-6" 13'-8" 1-34" 3 15,350 120 2,590

PF-18-8-7 18'-0" 7'-10" 7'-0" 4'-0" 40 4-VT-FLUR 19'-0" 8'-6" 11'-2" 1-42" 3 19,275 130 2,650

PF-18-8-10 18'-0" 7'-10" 10'-0" 4'-0" 40 4-OT-FLUR 19'-0" 8'-6" 14'-2" 1-42" 3 19,275 130 2,900

PF-18-10-7 18'-0" 9'-10" 7'-0" 4'-0" 50 4-VT-FLUR 19'-0" 10'-6" 11'-2" 1-42" 5 23,505 130 3,150

PF-18-10-10 18'-0" 9'-10" 10'-0" 4'-0" 50 5-OT-FLUR 19'-0" 10'-6" 14’-2" 1-42" 5 23,505 130 3,330

PF-18-12-7 18'-0" 11'-10" 7'-0" 4'-0" 60 4-VT-FLUR 19'-0" 12'-6" 11'-2" 1-42" 7 1/2 27,610 125 3,500

PF-18-12-7HV 18'-0" 11'-10" 7'-0" 3'-0" 60 4-VT-FLUR 19'-0" 12'-6" 10'-2" 2-30" 5 31,570 150 3,500

PF-18-12-10 18'-0" 11'-10" 10'-0" 4'-0" 60 5-OT-FLUR 19'-0" 12'-6" 14'-2" 1-42" 7 1/2 27,610 125 3,800

PF-18-12-10HV 18'-0" 11'-10" 10'-0" 3'-0" 60 5-OT-FLUR 19'-0" 12'-6" 13'-2" 2-30" 5 31,570 140 3,800

PF-20-7-10 20'-0" 6'-10" 10'-0" 4'-0" 44 5-OT-FLUR 21'-0" 7'-6" 14'-2" 1-42" 3 19,275 135 2,900

PF-20-7-10HV 20'-0" 6'-10" 10'-0" 3'-0" 44 5-OT-FLUR 21'-0" 7'-6" 13'-2" 2-30" 2 22,360 155 3,050

PF-20-7-12 20'-0" 6'-10" 12'-0" 4'-0' 44 6-OT-FLUR 21'-0" 7'-6" 16'-2" 1-42" 3 19,275 135 3,070

PF-20-7-12HV 20'-0" 6'-10" 12'-0" 3'-0" 44 6-OT-FLUR 21'-0" 7'-6" 15'-2" 2-30" 2 22,360 155 3,320

PF-20-8-10 20'-0" 7'-10" 10'-0" 4'-0" 44 5-OT-FLUR 21'-0" 8'-6" 14'-2" 1-42" 5 23,505 145 3,420

PF-20-8-12 20'-0" 7'-10" 12'-0" 4'-0" 44 6-OT-FLUR 21'-0" 8'-6" 16'-2" 1-42" 5 23,505 145 3,500

PF-20-10-10 20'-0" 9'-10" 10'-0" 4'-0" 55 6-OT-FLUR 21'-0" 10'-6" 14'-2" 1-42" 7 1/2 27,610 135 3,900

PF-20-10-10HV 20'-0" 9'-10" 10'-0" 3'-0" 55 6-OT-FLUR 21'-0" 10'-6" 13'-2" 2-30" 5 31,570 155 4,100

PF-20-10-12 20'-0" 9'-10" 12'-0" 4'-0" 55 7-OT-FLUR 21'-0" 10'-6" 16'-2" 1-42" 7 1/2 27,610 135 4,050

PF-20-10-12HV 20'-0" 9'-10" 12'-0" 3'-0" 55 7-OT-FLUR 21'-0" 10'-6" 15'-2" 2-30" 5 31,570 155 4,250

PF-20-12-10 20'-0" 11'-10" 10'-0" 4'-6" 66 6-OT-FLUR 21'-0" 12'-6" 14'-8" 1-48" 7 1/2 33,185 135 4,430

PF-20-12-12 20'-0" 11'-10" 12'-0" 4'-6" 66 7-OT-FLUR 21'-0" 12'-6" 16'-8" 1-48" 7 1/2 33,185 135 4,850

PF-22-7-10 22'-0" 6'-10" 10'-0" 4'-0" 52 6-OT-FLUR 23'-0" 7'-6" 14’-2" 1-42" 3 19,275 125 3,300

PF-22-7-12 22'-0" 6'-10" 12'-0" 4’-0" 52 7-OT-FLUR 23'-0" 7'-6" 16'-2" 1-42" 3 19,275 125 3,390

A

B

C DMODEL WIDTH HEIGHT WORKING PLENUM FILTER FLUOR. LIGHTS WIDTH HEIGHT DEPTH EXHAUST MOTOR C. F. M @ FACE SHIPPING NO. I. D I. D. DEPTH DEPTH CELLS NO. & TYPE OVERALL OVERALL OVERALL FAN H. P. 1/4" S. P. VELOCITY WEIGHT

(A) (B) (C) (D) 20X20X3 AVERAGE

©1999 BLEEKER BROS.

Page 10: BLEEKER DIGITAL CATALOG

Toll Free 800.421.1107 9

BLE

EK

ER

BLE

EK

ER

FLOOR FILTER BOOTHS

PF-22-8-10 22'-0" 7'-10" 10'-0" 4’-0" 52 6-OT-FLUR 23'-0" 8'-6" 14'-2" 1-42" 5 23,505 130 3,600

PF-22-8-10HV 22'-0" 7'-10" 10'-0" 3'-0" 52 6-OT-FLUR 23'-0” 8'-6” 13'-2" 2-30” 3 26,360 145 3,750

PF-22-8-12 22'-0" 7'-10" 12'-0" 4'-0" 52 7-OT-FLUR 23'-0” 8'-6” 16'-2" 1-42” 5 23,505 130 3,790

PF-22-8-12HV 22'-0" 7'-10" 12'-0" 3'-0" 52 7-OT-FLUR 23'-0” 8'-6” 15'-2" 2-30” 3 26,360 145 3,840

PF-22-10-10 22'-0" 9'-10" 10'-0" 4'-6" 65 7-OT-FLUR 23'-0” 10'-6” 14'-8" 1-48” 5 28,745 130 4,200

PF-22-10-12 22'-0" 9'-10" 12'-0" 4'-6" 65 8-OT-FLUR 23'-0” 10'-6” 16'-8" 1-48” 5 28,745 130 4,400

PF-22-12-10 22'-0" 11'-10" 10"-0" 4'-6" 78 7-OT-FLUR 23'-0” 12'-6” 14'-8" 1-48” 7 1/2 33,185 125 4,650

PF-22-12-12 22'-0" 11'-10" 12'-0" 4'-6" 78 8-OT-FLUR 23'-0" 12'-6” 16'-8" 1-48” 7 1/2 33,185 125 4,880

PF-24-7-10 24'-0" 6'-10" 10'-0" 4'-0" 56 6-OT-FLUR 25'-0" 7'-6” 14'-2" 1-42” 5 23,505 135 3,450

PF-24-7-12 24'-0" 6'-10" 12'-0" 4'-0" 56 6-OT-FLUR 25'-0" 7'-6” 16'-2" 1-42” 5 23,505 135 3,520

PF-24-8-10 24'-0" 7'-10" 10'-0" 4'-0" 56 6-OT-FLUR 25'-0" 8'-6” 14'-2" 1-42” 7 1/2 27,610 140 3,750

PF-24-8-10HV 24'-0" 7'-10" 10'-0" 3'-0" 56 6-OT-FLUR 25'-0" 8'-6" 13'-2" 2-30” 5 31,570 165 3,850

PF-24-8-12 24'-0" 7'-10" 12'-0" 4'-0" 56 6-OT-FLUR 25'-0" 8'-6" 16'-2" 1-42” 7 1/2 27,610 140 4,050

PF-24-8-12HV 24'-0" 7'-10" 12'-0" 3'-0" 56 6-OT-FLUR 25'-0" 8'-6" 15'-2" 2-30” 5 31,570 165 4,150

PF-24-10-10 24'-0" 9'-10" 10'-0" 4'-6" 70 8-OT-FLUR 25'-0" 10'-6" 14'-8" 1-48” 7 1/2 33,185 135 4,200

PF-24-10-12 24'-0" 9'-10" 12'-0" 4'-6" 70 8-OT-FLUR 25'-0" 10'-6" 16'-8" 1-48” 7 1/2 33,185 135 4,390

PF-24-12-10 24'-0" 11'-10" 10'-0" 3'-6" 84 8-OT-FLUR 25'-0" 12'-6" 13'-8" 2-36" 5 38,920 135 4,700

PF-24-12-12 24'-0" 11'-10" 12'-0" 3'-6" 84 8-OT-FLUR 25'-0" 12'-6" 15'-8" 2-36" 5 38,920 130 4,910

PF-26-7-10 26'-0" 6'-10" 10'-0" 4'-0" 60 6-OT-FLUR 27'0" 8'-0" 14'-2" 1-42" 5 23,505 125 3,900

PF-26-7-10HV 26'-0" 6'-10" 10'-0" 3'-0" 60 6-OT-FLUR 27'-0" 8'-0" 13'-2" 2-30" 3 26,360 140 4,050

PF-26-7-12 26'-0" 6'-10" 12'-0" 4'-0" 60 6-OT-FLUR 27'-0" 8'-0" 16'-2" 1-42" 5 23,505 125 4,080

PF-26-7-12HV 26'-0" 6'-10" 12'-0" 3'-0" 60 6-OT-FLUR 27'-0" 8'-0" 15'-2" 2-30" 3 26,360 140 5,130

PF-26-8-10 26'-0" 7'-10" 10'-0" 3'-0" 60 8-OT-FLUR 27'-0" 9'-0" 13'-2" 2-30" 3 26,360 125 4,450

PF-26-8-12 26'-0" 7'-10" 12'-0" 3'-0" 60 8-OT-FLUR 27'-0" 9'-0" 15'-2" 2-30" 3 26,360 125 5,310

PF-26-10-10 26'-0" 9'-10" 10'-0" 4'-6" 75 8-OT-FLUR 27'-0" 11'-0" 14'-8" 1-48" 7 1/2 33,185 125 5,000

PF-26-10-12 26'-0" 9'-10" 12'-0" 4'-6" 75 8-OT-FLUR 27'-0" 11'-0" 16'-8" 1-48" 7 1/2 33,185 125 5,200

PF-26-12-10 26'-0" 11'-10" 10'-0" 3'-6" 90 10-OT-FLUR 27'-0" 13'-0" 13'-8" 2-36" 5 38,920 125 5,800

PF-26-12-12 26'-0" 11'-10" 12'-0" 3'-6" 90 10-OT-FLUR 27'-0" 13'-0" 15'-8" 2-36" 5 38,920 125 6,020

PF-28-7-10 28'-0" 6'-10" 10'-0" 4'-0" 64 6-OT-FLUR 29'-0" 8'-0" 14'-2" 1-42" 7 1/2 27,610 140 4,300

PF-28-7-10HV 28'-0" 6'-10" 10'-0" 3'-0" 64 6-OT-FLUR 29'-0" 8'-0" 13'-2" 2-30" 5 31,570 160 4,300

PF-28-7-12 28'-0" 6'-10" 12'-0" 4'-0" 64 6-OT-FLUR 29'-0" 8'-0" 16'-2" 1-42" 7 1/2 27,610 140 4,490

PF-28-7-12HV 28'-0" 6'-10" 12'-0" 3'-0" 64 6-OT-FLUR 29'-0" 8'-0" 15'-2" 2-30" 5 31,570 160 4,490

PF-28-8-10 28'-0" 7'-10" 10'-0" 3'-0" 64 8-OT-FLUR 29'-0" 9'-0" 13'-2" 2-30" 5 31,570 140 4,650

PF-28-8-12 28'-0" 7'-10" 12'-0" 3'-0" 64 8-OT-FLUR 29'-0" 9'-0" 15'-2" 2-30" 5 31,570 140 4,690

PF-28-10-10 28'-0" 9'-10" 10'-0" 3'-6" 80 10-OT-FLUR 29'-0" 11'-0" 13'-8" 2-36" 5 38,920 135 5,100

PF-28-10-12 28'-0" 9'-10" 12'-0" 3'-6" 80 10-OT-FLUR 29'-0" 11'-0" 15'-8" 2-36" 5 38,920 135 5,310

PF-28-12-10 28'-0" 11'-10" 10'-0" 4'-0" 96 10-OT-FLUR 29'-0" 13'-0" 14'-2" 2-42" 5 47,010 140 6,200

PF-28-12-12 28'-0" 11'-10" 12'-0" 4'-0" 96 10-OT-FLUR 29'-0" 13'-0" 16'-2" 2-42" 5 47,010 140 6,430

PF-30-7-10 30'-0" 6'-10" 10'-0" 3'-0" 68 6-OT-FLUR 31'-0" 8'-0" 13'-2" 2-30" 3 26,360 125 4,350

PF-30-7-12 30'-0" 6'-10" 12'-0" 3'-0" 68 6-OT-FLUR 31'-0" 8'-0" 15'-2" 2-30" 3 26,360 135 4,550

PF-30-8-10 30'-0" 7'-10" 10'-0" 3'-0" 68 6-OT-FLUR 31'-0" 9'-0" 13'-2" 2-30" 5 31,570 130 5,000

PF-30-8-12 30'-0" 7'-10" 12'-0" 3'-0" 68 6-OT-FLUR 31'-0" 9'-0" 15'-2" 2-30" 5 31,570 130 5,200

PF-30-10-10 30'-0" 9'-10" 10'-0" 3'-6" 85 10-OT-FLUR 31'-0" 11'-0" 15'-8" 2-36" 5 38,920 125 5,750

PF-30-10-12 30'-0" 9'-10" 12'-0" 3'-6" 85 10-OT-FLUR 31'-0" 11'-0" 15'-8" 2-36" 5 38,920 125 5,975

PF-30-12-10 30'-0" 11'-10" 10'-0" 4'-0" 102 10-OT-FLUR 31'-0" 13'-0" 14'-2" 2-42" 5 47,010 130 7,000

PF-30-12-12 30'-0" 11'-10" 12'-0" 4'-0" 102 10-OT-FLUR 31'-0" 13'-0" 16'-2" 2-42" 5 47,010 130 7,240

A

B

C DMODEL WIDTH HEIGHT WORKING PLENUM FILTER FLUOR.LIGHTS WIDTH HEIGHT DEPTH EXHAUST MOTOR C. F. M @ FACE SHIPPING NO. I. D I. D. DEPTH DEPTH CELLS NO. & TYPE OVERALL OVERALL OVERALL FAN H. P. 1/4" S. P. VELOCITY WEIGHT

(A) (B) (C) (D) 20X20X3 AVERAGE

©1999 BLEEKER BROS.

Page 11: BLEEKER DIGITAL CATALOG

10 EMAIL: [email protected] www.BleekerBros.com

BLE

EK

ER

BENCH FILTER BOOTHS

4’-Wide Booth Only

Typical Vapor-TightIncandescent LightingArrangement, 300 watt.

Optional Explosion-proofLighting

Arrangement. 300 watt.Ordered on request.

Typical Vapor-TightFluorescent Lighting

Arrangement for Boothswider than 4’.

BENCH FILTER BOOTHPACKAGE

Includes:Fan & Motor

Exhaust Filters

Belt Guard

Nuts & Bolts

Manometer

Light Fixtures

Solenoid Valve

Filter Grids

Assembly Instructions

Not Included:Tubes or Bulbs

Sprinkler Systems

Duct Package

Electrical Switches

Motor Starter

Air Lines

Attachment anchors fromBooth to Floor

GENERAL INFORMATIONFeatures• All Bench-Type Paint Spray

Booths adhere to the Uniform Fire Code and the National Electrical Code. Always check local fire and electrical codes for special conditions that may prevail in your area.

• Incandescent Light Fixtures as listed are U.L. and C-U.L approved, 300 watt Vapor-Tight, adhering to Hazardous Class 1, Division 1 from the National Electrical Code.

• Vapor-Tight Fluorescent Fixtures are U.L. and C-U.L. approved and 4’-long, 4-tube, adhering to Hazardous Area Class 1, Division 2 from the National Electrical Code.

• All Light Fixtures are placed on the outside of 1/4” Clear Tempered Glass, gasketed and locked in place in the working depth of the Booth.

• Fan Motors are: 3-phase, 208/230/460 volt, 60 Hz.

• Light Fixtures are 120 volt.

• Solenoid Valve is single phase. Voltage must be stated (110/ 220 etc.).

• Fan Outlet: top is standard. Backor side outlet can be supplied butposition must be requested.

• Panels are skidded and banded for forklift handling.

• Fans, motors, filters, etc., are packaged but loose.

Additional Features Available• Conveyor Openings

• Explosion-proof Motors

• Working Depth Extensions

• Special Width or Height requirements

• Special Lighting Arrangements

• Can be shipped sub-assembled at additional cost.

• Contact Factory or Dealer for price adjustment.

NOTES

Booth dimensions and prices are subject to change without notice.

Shipment by Public Carrier hasspecial requirements. ContactFactory or Dealer.

Construction Features• 18-Gauge Galvanized Steel

panels

• Bolt Construction. Inside of Booth is smooth.

• Filter Cells are 20” X 20” X 3”.

• Light Windows contain 1/4” ClearTempered Glass

• Fans are belt driven with enclosed belt guards.

• Blades are rigid-type, spark-resistant and di-electric.

• Spray Booth Panels rest on heavy duty 14-Gauge GalvanizedFloor Angles.

• Face Velocity exceeds code requirement of 150 F.P.M.

• See specifications for Face Velocity of individual booths.

Page 12: BLEEKER DIGITAL CATALOG

BLE

EK

ER

Toll Free 800.421.1107 11

BLE

EK

ER

BENCH FILTER BOOTHS

BF-4-7 4'-0" 3'-0" 5'-2" 4 1-VT- INCD 1-18" 1/2 3010 185 500BF-5-7 5'-0" 3'-0" 5'-2" 6 1-VT- FLUR 1-18" 3/4 3635 180 650BF-6-7 6'-0" 3'-0" 5'-2" 6 1-VT- FLUR 1-18" 3/4 3635 150 850BF-8-7 8’-0" 4'-0" 6'-8" 8 1-VT- FLUR 1-24" 1 6260 195 1300BF-10-7 10'-0" 4'-0" 6'-8" 10 1-VT- FLUR 1-24" 1 1/2 7200 180 1600BF-12-7 12'-0" 4'-0" 6'-8" 14 2-VT- FLUR 1-24" 1 1/2 7200 150 2000

Features• All Bench-Type Paint Spray

Booths adhere to the Uniform Fire Code and the National Electrical Code. Always check local fire and electrical codes for special conditions that may prevail in your area.

• Fan Motors are single phase, explosion proof 120 volt, 60 Hz..

• Fan Outlet: top is standard. Back or side outlet can be supplied but position must be requested.

• Shipment by Public Carrier has special requirements. Contact Factory or Dealer.

3’-6” Wide

3’-6” Deep

3’-6” High

2’-7” Bench Height (withlegs)

6’-1” Height Overall (withlegs)

20” Working Depth

4-20” x 20” x 3” FilterCells

12” Diameter Fan

Belt Guard included

3/4 H. P. 1-PhaseExplosion-proof Motor

2000 C. F. M. @ 1/4” S. P.

Face Velocity 170 F. P. M.

2’-0” Wide

2’-6” Deep

2’-0” High

3’-4” Bench Height (withlegs)

5’-4” Height Overall (withlegs)

2’-0” Working Depth

1-20” x 20” x 3” Filter Cell

12” Diameter Fan

Belt Guard included

1/3 H. P. 1-PhaseExplosion-proof Motor

800 C. F. M. @ 1/4” S. P.

Face Velocity 200 F. P. M.

MODEL WIDTH WORKING DEPTH EXHAUST LIGHT EXHAUST MOTOR C. F. M. @ FACE SHIPPING NO. I. D. (A) DEPTH (B) OVERALL (C) FILTERS FIXTURES FAN H.P. 1/4" S. P. VELOCITY WEIGHT

SPECIAL APPLICATION BENCH FILTER BOOTHS

AC

B

NOTES

Booth dimensions and prices aresubject to change without notice.

Can be shipped sub-assembled atadditional cost

Bench Booths meet or exceed U.F. C. requirement of 150 feet perminute Face Velocity.

SPECIALAPPLICATIONBENCH FILTERBOOTH PACKAGE

Includes:Fan & Motor

Belt Guard

Exhaust Filters

Filter Grids

Manometer

Bench Legs

Assembly Instructions

Not Included:Light Fixtures

Solenoid Valve

Sprinkler Systems

Duct Package

Electrical Switches

Motor Starter

Air Lines

Attachment anchors fromBooth to Floor

BENCH BOOTHS

Touch-Up Booth BF-2 Light Duty Booth BF-3-1/2

©1999 BLEEKER BROS.

Page 13: BLEEKER DIGITAL CATALOG

12 EMAIL: [email protected] www.BleekerBros.com

BLE

EK

ER

VARSOL BENCH BOOTHS

BLEEKER BOOTHPACKAGE

Includes:Fan & Motor

Nuts & Bolts

Light Fixtures

Pump & Motor

Exhaust Filters

Tank (including fittings)

Assembly Instructions

10’ of Hose With SprayNozzle

Assembly Instructions

Not Included:Bulbs

Duct Package

Sprinkler Systems

Air Lines

Electrical Swtihes

Motor Starter

Attachment anchors fromBooth to Floor

Additional Features Available• Working depth extensions

• Special width or height requirements

• Special lighting arrangements

• Contact factory or dealer for priceadjustment.

NOTES

Booth dimensions and price aresubject to change without notice.

Varsol Booths meet or exceed U. F. C. requirement of 150 feet perminute face velocity

Features• All Varsol Spray Booths adhere

to the Uniform Fire Code and the National Electrical Code. Always check local fire and electrical codes for special conditions that may prevail in your area.

• Incandescent Light Fixtures are listed are U.L. and C-U.L. approved, 300-watt Explosion-proof, adhering to Hazardous Area Class 1, Division1 from the National Electrical Code.

• All Light Fixtures are placed on the outside of 1/4” Clear Tempered Glass, gasketed and locked in place in the working depth of the Booth.

• Fan motor is 3-phase, 230/460 volt, 60 Hz., explosion-proof.

• Fan Outlet: Top is standard. Backor side outlet can be supplied, but position must be requested.

• Panels are skidded and banded for forklift handling.

• Fans, motors, filters, etc. are packaged, but loose.

• Shipment by Public Carrier has special requirements. Contact Factory or Dealer.

• Shipped sub-assembled.

Galvanized Wire Mesh Filter

GENERAL INFORMATION

Page 14: BLEEKER DIGITAL CATALOG

Toll Free 800.421.1107 13

BLE

EK

ER

VARSOL BENCH BOOTHS

VB-4 4'-0" 4'-0" 2 1-EXPL-INCD 4'-4" 4'-8" 18" 1/2 3010 185 600

VB-5 5'-0" 4'-0" 3 1-EXPL-INCD 5'-4" 4'-8" 18" 3/4 3635 180 700

VB-6 6'-0" 4'-0" 3 1-EXPL-INCD 6'-4" 4'-8" 18" 1 4290 175 800

VB-8 8'-0" 5'-0" 4 2-EXPL-INCD 8'-4" 5'-8" 24" 1 6260 195 1200

MODEL WIDTH WORKING FILTER LIGHT WIDTH DEPTH EXHAUST MOTOR C. F. M. @ FACE SHIPPING NO. I. D. (A) DEPTH (B) CELLS 20X25X2 FIXTURES OVERALL OVERALL FAN H.P. 1/4" S. P. VELOCITY WEIGHT

BA 6”

• 18-Gauge Galvanized Steel Panels.

• 14-Gauge Galvanized Drip Pan.

• Booth stands on 14-Gauge Galvanized Legs.

• 14-Gauge Galvanized Collecting and Holding Tank. (30 Gal.)

• Grating is 1” Aluminum. (Work shelf)

• Bolt Construction. Inside of Booth is smooth.

• Filter Cells are 20” x 25” x 2”.

• Exhaust Filters are Galvanized Steel. (Can be cleaned for re-use)

• Light windows contain 1/4” ClearTempered Glass

• Fans are belt driven with enclosed belt guards.

• Blades are rigid-type and are spark-resistant and di-electric.

CONSTRUCTION FEATURES

©1999 BLEEKER BROS.

Page 15: BLEEKER DIGITAL CATALOG

14 EMAIL: [email protected] www.BleekerBros.com

BLE

EK

ER

POWDER CONTAINMENT BOOTHS

Additional Feature Available• Conveyor openings

• Explosion-proof motors

• Working depth extensions

• Special width or height requirerments

• Special lighting arrangements

• Contact factory or dealer for priceadjustment.

NOTES

Containment Powder Booths areNOT to be used for wet painting.

Booth dimensions and price aresubject to change without notice.

Face velocity exceeds 100 F.P.M.

Construction features• 18-gauge galvanized steel panels

• Bolt Construction. Inside of booth is smooth.

• Filter cells are 20” x 20” x 3”.

• Light windows contain 1/4” clear tempered glass.

• Fans are driven with enclosed belt guards.

• Blades are ridgid-type and are spark-resistant and di-electric.

• Spray booths rest on heavy duty 14-gauge galvanized floor angles.

Typical Vapor-TightFluorescent LightingArrangement 4-Tube.

(7' Working Depth)

Typical Vapor-Tight FluorescentLighting Arrangement 4-Tube

(7’ working depth)

4’ width only

Typical Open-typeFluorescent LightingArrangement 4-Tube.

(10' Working Depth)

GENERAL INFORMATION

Typical 2-Cell FinalFilter Arrangement

Typical 6-Cell FinalFilter Arrangement

Typical 8-Cell FinalFilter Arrangement

BLEEKER BOOTHPACKAGE

Includes:Fan & Motor

Solenoid Valve

Manometer (2)

Pressure Switch (2)

Light Fixtures

Nuts & Bolts

Pre-Filters

Pocket Filters

Final Filters (95% AshreaTest)

Assembly Instructions

Not Included:Tubes or Bulbs

Duct Package

Sprinkler Systems

Motor Starter

Electrical Switches or Hook-Up

Air lines

Attachment anchors frombooth to floor

Features • All Powder Containment Paint

Spray Booths adhere to the Uniform Fire Code and the National Electrical Code. Always check local fire and electrical codes for special conditions that may prevail in your area.

• Open-type Fluorescent Light Fixtures as listed are U.L. and C-U.L. approved, 4’ long, 4-tube.

• Vapor-tight Fluorescent Fixtures are U.L. and C-U.L. approved, 4’ long, 4-tube, adhering to Hazardous Area Class 1,Division 2 from the National Electrical Code.

• All light fixtures are placed on the outside of 1/4” clear tempered glass, gasketed and locked in place in the working depth of the booth.

• Fan motors are 3-phase, 208/230/460 volt, 60 Hz.

• Light fixtures are 120 volt.

• Solenoid valve is a single phase. Voltage must be stated. (110/220) etc.

• Pressure switches installed as perinstructions.

• Panels are skidded and banded for forklift handling.

• Fans, motors, filters, etc. are packaged, but loose.

• Shipment by public carrier has special requirements. Contact factory or dealer.

Page 16: BLEEKER DIGITAL CATALOG

Toll Free 800.421.1107 15

BLE

EK

ER

POWDER CONTAINMENT BOOTHS

C-4-7-7 4'-0" 6'-10" 7'-0" 2'-0" 3'-7" 8 2 1-VT-FLUR 4'-4" 7'-4" 9'-2" 1-18" 1-1/2 3,800 135 960

C-4-8-7 4'-0" 7'-10" 7'-0" 2'-0" 3'-7" 8 2 1-VT-FLUR 4'-4" 8'-4" 9'-2" 1-18" 1-1/2 3,800 118 990

C-5-7-7 5'-0" 6'-10" 7'-0" 2'-6" 3'-8" 12 4 1-VT-FLUR 5'-4" 7'-4" 9'-8" 1-24" 2 6,490 185 1120

C-5-8-7 5'-0" 7'-10" 7'-0" 2'-6" 3'-8" 12 4 1-VT-FLUR 5'-4" 8'-4" 9'-8" 1-24" 2 6,490 162 1220

C-6-7-7 6'-0" 6'-10" 7'-0" 2'-6" 3'-8" 12 4 1-VT-FLUR 6'-4" 7'-4" 9'-8" 1-24" 2 6,490 154 1220

C-6-8-7 6'-0" 7'-10" 7'-0" 2'-6" 3'-8" 12 4 1-VT-FLUR 6'-4" 8'-4" 9'-8" 1-24" 2 6,490 135 1270

C-8-7-7 8'-0" 6'-10" 7'-0" 2'-6" 3'-8" 16 4 1-VT-FLUR 8'-4" 7'-4" 9'-8" 1-24" 2 6,490 115 1305

C-8-8-7 8'-0" 7'-10" 7'-0" 3'-0" 4'-2" 16 6 1-VT-FLUR 8'-4" 8'-4" 10'-2" 1-30" 3 9,740 152 1395

C-10-7-7 10'-0" 6'-10" 7'-0" 3'-0" 4'-2" 20 6 2-VT-FLUR 10'-4" 7'-4" 10'-2" 1-30" 3 9,740 139 1730

C-10-8-7 10'-0" 7'-10" 7'-0" 3'-0" 4'-2" 20 6 2-VT-FLUR 10'-4" 8'-4" 10'-2" 1-30" 3 9,740 120 1830

C-10-10-7 10'-0" 9'-10" 7'-0" 3'-6" 5'-5" 25 8 2-VT-FLUR 10'-4" 10'-4" 10'-8" 1-34" 5 14,445 144 2080

C-10-12-7 10'-0" 11'-10" 7'-0" 3'-6" 5'-5" 30 8 2-VT-FLUR 10'-4" 12'-4" 10'-8" 1-34" 5 14,445 120 2390

C-12-7-7 12'-0" 6'-10" 7'-0" 3'-6" 5'-5" 28 8 2-VT-FLUR 12'-4" 7'-4" 10'-8" 1-34" 5 14,445 170 2040

C-12-8-7 12'-0" 7'-10" 7'-0" 3'-6" 5'-5" 28 8 2-VT-FLUR 12'-4" 8'-4" 10'-8" 1-34" 5 14,445 150 2240

C-12-10-7 12'-0" 9'-10" 7'-0" 3'-6" 5'-5" 35 8 3-VT-FLUR 12'-4" 10'-4" 10'-8" 1-34" 5 14,445 120 2540

C-12-12-7 12'-0" 11'-10" 7'-0" 4'-0" 5'-8" 42 12 3-VT-FLUR 12'-4" 12'-4" 11'-2" 1-42" 7-1/2 21,775 150 3010

C-14-7-10 14'-0" 6'-10" 10'-0" 3'-6" 5'-5" 32 8 4-OT-FLUR 15'-0" 7'-6" 13'-8" 1-34" 5 14,445 147 2500

C-14-8-10 14'-0" 7'-10" 10'-0" 3'-6" 5'-5" 32 8 4-OT-FLUR 15'-0" 8'-6" 13'-8" 1-34" 5 14,445 128 2615

C-14-10-10 14'-0" 9'-10" 10'-0" 4'-0" 5'-8" 40 12 4-OT-FLUR 15'-0" 10'-6" 14'-2" 1-42" 7-1/2 21,775 155 3060

C-14-12-10 14'-0" 11'-10" 10'-0" 4'-0" 5'-8" 48 12 4-OT-FLUR 15'-0" 12'-6" 14'-2" 1-42" 7-1/2 21,775 129 3540

C-16-7-10 16'-0" 6'-10" 10'-0" 3'-6" 5'-5" 36 8 3-OT-FLUR 17'-0" 7'-6" 13'-8" 1-34" 5 14,445 128 2665

C-16-8-10 16'-0" 7'-10" 10'-0" 3'-6" 5'-5" 36 8 4-OT-FLUR 17'-0" 8'-6" 13'-8" 1-34" 5 14,445 112 2830

C-16-10-10 16'-0" 9'-10" 10'-0" 3'-0" 4'-2" 45 12 5-OT-FLUR 17'-0" 10'-6" 13'-2" 2-30" 2-3 19,480 121 3605

C-16-12-10 16'-0" 11'-10" 10'-0" 3'-6" 5'-5" 54 16 5-OT-FLUR 17'-0" 12'-6" 13'-8" 2-34" 2-5 28,890 150 4120

C-18-7-10 18'-0" 6'-10" 10'-0" 3'-6" 5'-5" 40 8 4-OT-FLUR 19'-0" 7'-6" 13'-8" 1-36" 5 14,825 117 2830

C-18-8-10 18'-0" 7'-10" 10'-0" 3'-0" 4'-2" 40 12 4-OT-FLUR 19'-0" 8'-6" 13'-2" 2-30" 2-3 19,480 135 3260

C-18-10-10 18'-0" 9'-10" 10'-0" 3'-6" 5'-5" 50 16 5-OT-FLUR 19'-0" 10'-6" 13'-8" 2-34" 2-5 28,890 160 3690

C-18-12-10 18'-0" 11'-10" 10'-0" 3'-6" 5'-5" 60 16 5-OT-FLUR 19'-0" 12'-6" 13'-8" 2-34" 2-5 28,890 133 4280

C-20-7-10 20'-0" 6'-10" 10'-0" 3'-0" 4'-2" 44 12 5-OT-FLUR 21'-0" 7'-6" 13'-2" 2-30" 2-3 19,480 139 3260

C-20-8-10 20'-0" 7'-10" 10'-0" 3'-0" 4'-2" 44 12 5-OT-FLUR 21'-0" 8'-6" 13'-2" 2-30" 2-3 19,480 121 3780

C-20-10-10 20'-0" 9'-10" 10'-0" 3'-6" 5'-5" 55 16 6-OT-FLUR 21'-0" 10'-6" 13'-8" 2-34" 2-5 28,890 144 4320

C-20-12-10 20'-0" 11'-10" 10'-0" 3'-6" 5'-5" 66 16 6-OT-FLUR 21'-0" 12'-6" 13'-8" 2-34" 2-5 28,890 120 4320

MODEL WIDTH HEIGHT WORKING PLENUM UPPER FILTER FINAL LIGHTS WIDTH HEIGHT DEPTH EXHAUST MOTOR C. F. M @ FACE SHIPPINGNo. I. D I. D. DEPTH DEPTH PLENUM CELLS FILTERS NO. OVERALL OVERALL OVERALL FAN H. P. 1" S. P. VELOCITY WEIGHT

(A) (B) (C) (D) (E) & TYPE AVERAGE

Powder ContainmentBooths are NOT tobe used for wetpainting or blasting.

A C D

E

B

©1999 BLEEKER BROS.

Page 17: BLEEKER DIGITAL CATALOG

16 EMAIL: [email protected] www.BleekerBros.com

BLE

EK

ER

POWDER CONTAINMENT BENCH BOOTHS

Typical Vapor-tight Florescent LightingArrangement. 4-tubes (5’ width)

Typical 4-Cell Final Filter Arrangement

GENERAL INFORMATION

Features• All Industrial Paint Spray

Booths adhere to the Uniform Fire Code and the National Electrical Code. Always check local fire and electrical codes for special conditions that may prevail in your area.

• Incandescent Light fixtures are listed as U.L. and C-U.L. approved, 300-watt, Vapor-Tight, adhering to Hazardous Area Class 1, Division1 from the National Electrical Code.

• Vapor-tight Fluorescent Fixtures are U.L. and C-U.L. approved,4’ long, 4-tube, adhering to Hazardous Area Class 1, Division 2 from the National Electrical Code.

• All Light Fixtures are placed on the outside of 1/4” Clear Tempered Glass, gasketed and locked in place in the working depth of the booth.

• Fan Motors are 3-phase, 208/230/460 volt, 60 Hz.

• Light Fixtures are 120 volt.

• Solenoid Valve is a single phase. Voltage must be stated. (110/220)etc.

BLEEKER BOOTHPACKAGE

Includes:Fan & Motor

Solenoid Valve

Manometer (2)

Light Fixtures

Nuts & Bolts

Pre-Filters

Pocket Filters

Final Filters (95% AshreaTest)

Pressure Switch (2)

Assembly Instructions

Not Included:Tubes or Bulbs

Duct Package

Sprinkler Systems

Motor Starter

Electrical Switches or Hook-Up

Air lines

Attachment anchors fromBooth to floor

Cross-section

• Pressure Switches installed as per instructions.

• Panels are skidded and banded for forklift handling.

• Fans, motors, filters, etc. are packaged, but loose.

• Shipment by Public Carrier has special requirements. Contact Factory or Dealer.

Additional Features Available: • Conveyor Openings

• Explosion-Proof Motors

• Working Depth Extensions

• Special Width or Height Requirements

• Special Lighting Arrangements

• Contact Factory or Dealer for price adjustment.

NOTES

Booth dimensions and price aresubject to change without notice.

Page 18: BLEEKER DIGITAL CATALOG

Toll Free 800.421.1107 17

BLE

EK

ER

POWDER CONTAINMENT BENCH BOOTHS

CB-3.5 3'-6" 3'-0" 3'-8" 4 2 1-VT-INCD 18" 1 1950 130 650

CB-4 4'-0" 3'-0" 5'-2" 4 2 1-VT-INCD 18" 1 1950 120 700

CB-5 5'-0" 3'-0" 5'-2" 6 2 1-VT-FLUR 18" 1.5 2400 120 850

CB-6 6'-0" 3'-0" 5'-2" 6 2 1-VT-FLUR 18" 1.5 3000 125 1050

CB-8 8'-0" 4'-0" 6'-8" 8 4 1-VT-FLUR 24" 2 3840 120 1600

CB-10 10'-0" 4'-0" 6'-8" 10 4 1-VT-FLUR 24" 2 4800 120 1900

CB-12 12'-0" 4'-0" 6'-8" 14 4 2-VT-FLUR 24" 2 6490 135 2300

A

MODEL WIDTH WORKING OVERALL EXHAUST FINAL LIGHT EXHAUST MOTOR C. F. M. @ FACE SHIPPING NO. I. D. (A) DEPTH (B) DEPTH (C) FILTERS FILTERS FIXTURES FAN H.P. 1" S. P. VELOCITY WEIGHT

• 18-Gauge Galvanized Steel Panels

• Bolt Construction. Inside of Booth is smooth.

• Filter Cells are 20” X 20” X 3”

• Light Windows contain 1/4” ClearTempered Glass.

• Fans are driven with enclosed belt guards.

• Blades are rigid-type and are spark-resistant and di-electric.

• Spray Booths rest on heavy duty 14-Gauge Galvanized Floor Angles.

• Face Velocity exceeds 100 F. P.M.

PLENUMBC

NOTE

Powder Containment Bench Boothsare NOT to be used for wet painting.

CONSTRUCTION FEATURES

©1999 BLEEKER BROS.

Page 19: BLEEKER DIGITAL CATALOG

18 EMAIL: [email protected] www.BleekerBros.com

BLE

EK

ER

The ultimate in "Cartridge Batch"Powder Spray Booths is offered byBLEEKER BROS., to manufacturerswho are affected by the ever-increasing demands for betteremission controls and higher paintingcosts. We at Bleeker Bros. believewe have in our catalog a size or typeof booth that can best serve yourneeds. Single Color or "Multicolor"Booths are listed and ready for one ofour experienced Dealers to help youwith your needs.

These booths are available in twoplenum styles, depending on yourspecific application needs.

Powderrecovery from aFluidized Bed isused when continuous production isrequired. The powder can bepumped directly into containers to bereclaimed. When multicolorapplication is required, a colorchange collector is required for eachcolor change.

Powderrecovery through Removable Draweris used when down time is availableto properly recover powder fromdrawer, and are used for single colorand non-reclaim applications. If colorchange usage is required, a Roll-awayPlenum with a Fluidized Bed may beordered for each color change.

Features• All Industrial Paint Spray

Booths adhere to the Uniform Fire Code and the National Electrical Code. Always check local fire and electrical codes for special conditions that may prevail in your area.

• Vapor-Tight Fluorescent Fixtures as listed are U.L. and C.U.L. approved, 4'-long, 4-tube, adhering to Hazardous Area Class 1, Division 2 from the National Electrical Code.

• Working depth panels are skidded and banded for forklift handling. Exhaust plenum shipped sub-assembled.

• Shipment by Public Carrier has special requirements. Contact Factory or Dealer.

Construction Features:• Plenum Exhaust Section

Including:

Exhaust blower & motor

Cartridge filters

Final filters

• Blower & Filter Controls are housed in one Pre-Wired Control Panel.

• Powder Recovery Options:

Fixed Fluidized Bed

Roll-away Fluidized Bed (formulticolor application)

Removable drawer

• Filters are self-cleaning, purged by a pulse of compressed air. (Compressed air supplied by others).

• Filters can last indefinitely if maintained properly.

• Spray Booth Panels rest on heavyduty 14-Gauge Galvanized Floor Angles.

• 18-Gauge Steel Panels used in Working Depth.

• 12-Gauge and 14-Gauge Steel Panels used in Exhaust Penum

• Bolt Construction. Inside of boothis smooth.

NOTE

Cartridge containment boothsexceed U.F.C. requirements of 100FPM Face Velocity

For each color change andadditional color change, plenummust be ordered. Contact Factoryor Dealer for price adjustment.

Filter and Monitoring Equipmentmay be required at additional costs.

Booth dimensions and price aresubject to change without notice.

Contact Local Agency to assure compliance with code requirements.

CARTRIDGE-BATCH TYPE & PRODUCTION TYPE POWDER BOOTHS

With FluidizedBed

BLEEKERBOOTHPACKAGE

Includes:Blower & Motor

Cartridge Filters

Final Filters

Solenoid Valve

Manometer

Nuts & Bolts

Light Fixtures

Assembly Instructions

Pre-Wired Control Panel

Not Included:Tubes or Bulbs

Sprinkler Systems

Duct Package

Light Switches

Electrical Hook-Up

Air Lines

Attachment anchors fromBooth to Floor

Air Dryer (critical to filterprotection)

GENERAL INFORMATION

With Drawer

PRODUCTIONBOOTH

BATCHBOOTH

Page 20: BLEEKER DIGITAL CATALOG

Toll Free 800.421.1107 19

BLE

EK

ER

CARTRIDGE-BATCH TYPE & PRODUCTION TYPE POWDER BOOTHS

BCP-5-7-5 5'-0" 6'-10" 5'-0" 9'-2" 1-VT-FLUR 1-7 1/2 4,375 125 3,200 BCP-5-7-7 5'-0" 6'-10" 7'-0" 11'-2" 1-VT-FLUR 1-7 1/2 4,375 125 3,300 BCP-5-8-5 5'-0" 7'-10" 5'-0" 9'-2" 1-VT-FLUR 1-7 1/2 5,000 125 3,250 BCP-5-8-7 5'-0" 7'-10" 7'-0" 11'-2" 1-VT-FLUR 1-7 1/2 5,000 125 3,350 BCP-6-7-5 6'-0" 6'-10" 5'-0" 9'-2" 1-VT-FLUR 1-7 1/2 5,250 125 3,500 BCP-6-7-7 6'-0" 6'-10" 7'-0" 11'-2" 1-VT-FLUR 1-7 1/2 5,250 125 3,600 BCP-6-8-5 6'-0" 7'-10" 5'-0" 9'-2" 1-VT-FLUR 1-7 1/2 6,000 125 3,550 BCP-6-8-7 6'-0" 7'-10" 7'-0" 11'-2" 1-VT-FLUR 1-7 1/2 6,000 125 3,600 BCP-8-7-5 8'-0" 6'-10" 5'-0" 9'-2" 1-VT-FLUR 1-10 7,000 125 4,000 BCP-8-7-7 8'-0" 6'-10" 7'-0" 11'-2" 1-VT-FLUR 1-10 7,000 125 4,100 BCP-8-8-5 8'-0" 7'-10" 5'-0" 9'-2" 1-VT-FLUR 1-10 8,000 125 4,050 BCP-8-8-7 8'-0" 7'-10" 7'-0" 11'-2" 1-VT-FLUR 1-10 8,000 125 4,150 BCP-8-10-5 8'-0" 9'-10" 5'-0" 9'-2" 1-VT-FLUR 1-15 12,000 125 4,080 BCP-8-10-7 8'-0" 9'-10" 7'-0" 11'-2" 2-VT-FLUR 1-15 12,000 125 4,400 BCP-10-7-7 10'-0" 6'-10" 7'-0" 11'-2" 2-VT-FLUR 1-10 8,750 125 4,600 BCP-10-7-10 10'-0" 6'-10" 10'-0" 14'-2" 2-VT-FLUR 1-10 8,750 125 4,750 BCP-10-8-7 10'-0" 7'-10" 7'-0" 11'-2" 2-VT-FLUR 1-15 10,000 125 4,900 BCP-10-8-10 10'-0" 7'-10" 10'-0" 14'-2" 2-VT-FLUR 1-15 10,000 125 4,960 BCP-10-10-7 10'-0" 9'-10" 7'-0" 11'-2" 2-VT-FLUR 1-15 12,000 120 5,020 BCP-10-10-10 10'-0" 9'-10" 10'-0" 14'-2" 3-VT-FLUR 1-15 12,000 120 5,300 BCP-12-7-7 12'-0" 6'-10" 7'-0" 11'-2" 2-VT-FLUR 1-15 10,500 125 5,550 BCP-12-7-10 12'-0" 6'-10" 10'-0" 14'-2" 3-VT-FLUR 1-15 10,500 125 5,700 BCP-12-8-7 12'-0" 7'-10" 7'-0" 11'-2" 2-VT-FLUR 1-15 10,500 125 5,750 BCP-12-8-10 12'-0" 7'-10" 10'-0" 14'-2" 3-VT-FLUR 1-15 12,000 125 5,950 BCP-12-10-7 12'-0" 9'-10" 7'-0" 11'-2" 3-VT-FLUR 1-20 15,000 125 6,000 BCP-12-10-10 12'-0" 9'-10" 10'-0" 14'-2" 3-VT-FLUR 1-20 15,000 125 6,150 BCP-12-12-7 12'-0" 11'-10" 7'-0" 11'-2" 3-VT-FLUR 1-20 16,500 125 6,050 BCP-12-12-10 12'-0" 11'-10" 10'-0" 14'-2" 4-VT-FLUR 1-20 16,500 125 6,350

A

1’0”

VARIES VARIES

10’0”

4’0”

8’0”

2’0”

1’0”

A+4”

1’0”

VARIES

10’0”

A +12”

1’0”

VARIES

2’0”

2’0”

6’0”

4’0”FRONT ELEVATION

B

CD

MODEL . WIDTH HEIGHT WORKING DEPTH LIGHTS MOTOR AVERAGE AVERAGE SHIPPINGNO. I. D. (A) I. D. (B) DEPTH (C) OVERALL (D) H.P. C.F.M. FACE VELOCITY WEIGHT

PCP-5-7-5 5'-0" 6'-10" 5'-0" 9'-2" 1-VT-FLUR 1-7 1/2 4,375 125 3,200 PCP-5-7-7 5'-0" 6'-10" 7'-0" 11'-2" 1-VT-FLUR 1-7 1/2 4,375 125 3,300 PCP-5-8-5 5'-0" 7'-10" 5'-0" 9'-2" 1-VT-FLUR 1-7 1/2 5,000 125 3,250 PCP-5-8-7 5'-0" 7'-10" 7'-0" 11'-2" 1-VT-FLUR 1-7 1/2 5,000 125 3,350 PCP-6-7-5 6'-0" 6'-10" 5'-0" 9'-2" 1-VT-FLUR 1-7 1/2 5,250 125 3,500 PCP-6-7-7 6'-0" 6'-10" 7'-0" 11'-2" 1-VT-FLUR 1-7 1/2 5,250 125 3,600 PCP-6-8-5 6'-0" 7'-10" 5'-0" 9'-2" 1-VT-FLUR 1-7 1/2 6,000 125 3,550 PCP-6-8-7 6'-0" 7'-10" 7'-0" 11'-2" 1-VT-FLUR 1-7 1/2 6,000 125 3,600 PCP-8-7-5 8'-0" 6'-10" 5'-0" 9'-2" 1-VT-FLUR 1-10 7,000 125 4,000 PCP-8-7-7 8'-0" 6'-10" 7'-0" 11'-2" 1-VT-FLUR 1-10 7,000 125 4,100 PCP-8-8-5 8'-0" 7'-10" 5'-0" 9'-2" 1-VT-FLUR 1-10 8,000 125 4,050 PCP-8-8-7 8'-0" 7'-10" 7'-0" 11'-2" 1-VT-FLUR 1-10 8,000 125 4,150 PCP-8-10-5 8'-0" 9'-10" 5'-0" 9'-2" 1-VT-FLUR 1-15 12,000 125 4,080 PCP-8-10-7 8'-0" 9'-10" 7'-0" 11'-2" 2-VT-FLUR 1-15 12,000 125 4,400 PCP-10-7-7 10'-0" 6'-10" 7'-0" 11'-2" 2-VT-FLUR 1-10 8,750 125 4,600 PCP-10-7-10 10'-0" 6'-10" 10'-0" 14'-2" 2-VT-FLUR 1-10 8,750 125 4,750 PCP-10-8-7 10'-0" 7'-10" 7'-0" 11'-2" 2-VT-FLUR 1-15 10,000 125 4,900 PCP-10-8-10 10'-0" 7'-10" 10'-0" 14'-2" 2-VT-FLUR 1-15 10,000 125 4,960 PCP-10-10-7 10'-0" 9'-10" 7'-0" 11'-2" 2-VT-FLUR 1-15 12,000 120 5,020 PCP-10-10-10 10'-0" 9'-10" 10'-0" 14'-2" 3-VT-FLUR 1-15 12,000 120 5,300 PCP-12-7-7 12'-0" 6'-10" 7'-0" 11'-2" 2-VT-FLUR 1-15 10,500 125 5,550 PCP-12-7-10 12'-0" 6'-10" 10'-0" 14'-2" 3-VT-FLUR 1-15 10,500 125 5,700 PCP-12-8-7 12'-0" 7'-10" 7'-0" 11'-2" 2-VT-FLUR 1-15 10,500 125 5,750 PCP-12-8-10 12'-0" 7'-10" 10'-0" 14'-2" 3-VT-FLUR 1-15 12,000 125 5,950 PCP-12-10-7 12'-0" 9'-10" 7'-0" 11'-2" 3-VT-FLUR 1-20 15,000 125 6,000 PCP-12-10-10 12'-0" 9'-10" 10'-0" 14'-2" 3-VT-FLUR 1-20 15,000 125 6,150 PCP-12-12-7 12'-0" 11'-10" 7'-0" 11'-2" 3-VT-FLUR 1-20 16,500 125 6,050 PCP-12-12-10 12'-0" 11'-10" 10'-0" 14'-2" 4-VT-FLUR 1-20 16,500 125 6,350

MODEL . WIDTH HEIGHT WORKING DEPTH LIGHTS MOTOR AVERAGE AVERAGE SHIPPING NO I. D. (A) I. D. (B) DEPTH (C) OVERALL (D) H.P. C.F.M. FACE VELOCITY WEIGHT

A

B

CD

BATCH CARTRIDGE POWDER BOOTHS - DRAWER STYLE

PRODUCTION CARTRIDGE POWDER BOOTHS - FLUIDIZED BED

Production CartridgePowder Booth PCP(for multiple colorchanges/reclaim)

Batch CartridgePowder Booth BCP(non-reclaim)

SIDE ELEVATION

©1999 BLEEKER BROS.

©1999 BLEEKER BROS.

Page 21: BLEEKER DIGITAL CATALOG

20 EMAIL: [email protected] www.BleekerBros.com

BLE

EK

ER

AUTO & VAN FILTER BOOTHS - CROSSDRAFT

AUTO & VAN DRIVE-THROUGH FILTER BOOTHS

• This booth is recommended where adequate working area is available.

• Incorporates both front filtered doors and solid rear doors.

• Auto filter doors are 9’-0” wide x 8’-6” high.

• Van filter doors are 9’-0” wide x 9’-6” high.

• Auto solid doors are 9’-0” wide x 7’-8” high.

• Van solid doors are 9’-0” wide x 8’-8” high.

• Allows entrance or exit through either end of booth forbetter workflow, or movement of painted vehicles to flash-off or oven enclosure.

• Personnel doors are 2’-6” wide X 6’-8” high with 1/4”clear tempered glass window.

SELECTING YOUR BOOTH STYLE

AUTO & VAN REAR-DRIVE FILTER BOOTHS

• Rear-drive style is also known as reverse flow.

• Entrance through solid doors at the rear of booth.

• Auto solid doors are 9’-0” wide x 7’-8” high

• Van solid doors are 9’-0” wide x 8’-8” high.

• This booth is recommended when at least 3 feet of clearance can be given at the front of the booth to allow for air intake.

• The advantage of this booth is that the airborne dirt from leaks that inevitably develop around all booth entrance doors will pass directly into the exhaust chamber without passing over the newly painted vehicle.

• Personnel doors are 2’-6” wide x 6’-8” high with 1/4“ clear tempered glass window.

AUTO & VAN SOLID-BACK FILTER BOOTHS

• This style is the most widely used in the painting industry.

• Entrance through filtered doors located at front of booth.

• Auto filter doors are 9’-0” wide x 8’-6” high.

• Van filter doors are 9’-0” wide x 9’-6” high.

• Solid back allows back of booth to be against a wall or other obstruction if necessary.

• Personnel doors are 2’-6” wide x 6’-8” high with clear tempered glass window.

Page 22: BLEEKER DIGITAL CATALOG

Toll Free 800.421.1107 21

BLE

EK

ER

AUTO & VAN FILTER BOOTHS - CROSSDRAFT

Features• All Industrial Paint Spray

Booths adhere to the Uniform Fire Code and the National Electrical Code. Always check local fire and electrical codes for special conditions that may prevail in your area.

• Open-Type Fluorescent Light Fixtures as listed are U.L. and C-U.L. approved, 4’ long, 4-tubes.

• Vapor-Tight Fluorescent Fixtures as listed are U.L. and C-U.L. approved, 4’-long, 4-tubes, adhering to Hazardous Area Class1, Division 2 from the National Electrical Code.

• All Light Fixtures are placed on the outside of 1/4” Clear Tempered Glass, gasketed and locked in place in the working depth of the Booth.

• Fan Motors are 3-phase, 208/230/460 volt, 60 Hz.

• Light Fixtures are 120 volt.

• Solenoid Valve is single phase. Voltage must be stated (110/220 etc.).

• Fan Outlet: top is standard. Back or side outlet can be supplied but position must be requested.

• Panels are skidded and banded for forklift handling.

• Fans, motors, filters, etc., are packaged but loose.

• Shipment by Public Carrier has special requirements. Contact Factory or Dealer.

GENERAL INFORMATION

DRIVE-THROUGH STYLEREAR-DRIVE STYLESOLID-BACK STYLE

FULL-FEATUREBLEEKER BOOTHPACKAGE

Includes:Fan & Motor

Exhaust Filters

Door Limit Switches

Solenoid Valve

Nuts & Bolts

Manometer

Light Fixtures

Assembly Instructions

Not Included:Tubes or Bulbs

Duct Package

Sprinkler Systems

Air Lines

Electrical Switches

Motor Starter

Attachment anchors fromBooth to Floor

Electrical Hook-Up

NOTESLighting quantity is verysubjective. Adding or deductingthe quantities of light fixtures caneasily be made to our bootharrangements without losing thefinancial advantage of purchasinga packaged booth.

Contact Factory or Dealer for priceadjustment.

Booth dimensions and price are subject to change without notice.

BLEEKER BROS. Automotive stylebooths are available in two lightingarrangements to fit your budget andneeds.

FULL-FEATURE (as shown) is ourrecommended automotive stylebooth and includes sidelights, doorlimit switches and solenoid valve.

BASIC-FEATURE Lighting Layoutwithout vapor-tight lights, door limitswitches or solenoid valve. To orderadd “X” to model number.

FULL-FEATURE models are specifiedthroughout this catalog.

Additional Features Available• Conveyor openings

• Explosion-proof motors

• Working depth extensions

• Special width or height requirements

• Special lighting arrangements

• BLEEKER- CURE™ Infra-Red

• Recirculating heat system package

• Contact factory or dealer for price adjustment

Construction Features• 18-gauge steel panels.

• Bolt Construction. Inside of booth is smooth.

• Filter Cells are 20” X 20” X 3”.

• Light Windows contain 1/4” cleartempered glass.

• Fans are belt driven with enclosed belt guards.

• Blades are rigid-type, spark-resistant and di-electric.

• Spray booth panels rest on heavyduty 14-Gauge, galvanized floor angles.

• Face Velocity exceeds code requirement of 100 F. P. M.

FULL-FEATURE

BASIC-FEATURE

FULL-FEATURE

Page 23: BLEEKER DIGITAL CATALOG

22 EMAIL: [email protected] www.BleekerBros.com

BLE

EK

ER

A

AUTO FILTER BOOTHS

ASB-18 18'-8" 20 18 3-OT-5VT 1 PAIR ONE NONE 34" 2 12,500 4,000

ASB-23 23'-8" 20 18 7-OT-5VT 1 PAIR ONE NONE 34" 2 12,500 5,000

ASB-26 26'-2" 20 18 7-OT-5VT 1 PAIR ONE NONE 34" 2 12,500 5,500

ASB-28 28'-8" 20 18 9-OT-5VT 1 PAIR ONE NONE 34" 2 12,500 5,900

ASB-33 33'-8" 20 18 13-OT-5VT 1 PAIR ONE NONE 34" 2 12,500 6,800

AUTO SOLID-BACK STYLE FILTER BOOTH MODEL

ADT-18 18'-8" 20 18 3-OT-5VT 1 PAIR ONE 1 PAIR 34" 2 12,500 4,300 ADT-23 23'-8" 20 18 7-OT-5VT 1 PAIR ONE 1 PAIR 34" 2 12,500 5,300 ADT-26 26'-2" 20 18 7-OT-5VT 1 PAIR ONE 1 PAIR 34" 2 12,500 5,800 ADT-28 28'-8" 20 18 9-OT-5VT 1 PAIR ONE 1 PAIR 34" 2 12,500 6,200 ADT-33 33'-8" 20 18 13-OT-5VT 1 PAIR ONE 1 PAIR 34" 2 12,500 7,100

ARD-18 18'-8" 20 18 3-OT-5VT NONE ONE 1 PAIR 34" 2 12,500 4,000

ARD-23 23'-8" 20 18 7-OT-5VT NONE ONE 1 PAIR 34" 2 12,500 5,000

ARD-26 26'-2" 20 18 7-OT-5VT NONE ONE 1 PAIR 34" 2 12,500 5,500

ARD-28 28'-8" 20 18 9-OT-5VT NONE ONE 1 PAIR 34" 2 12,500 5,900

ARD-33 33'-8" 20 18 13-OT-5VT NONE ONE 1 PAIR 34" 2 12,500 6,800

AUTO REAR-DRIVE STYLE FILTER BOOTH MODEL

AUTO DRIVE-THROUGH STYLE FILTER BOOTH MODEL

MODEL NO. DEPTH INTAKE EXHAUST LIGHT FRONT ACCESS REAR EXHAUST MOTOR C. F. M. @ SHIPPING OVERALL FILTERS FILTERS FIXTURES DOOR DOOR DOOR FAN DIA. H.P. 3/8" S. P. WEIGHT

(A)

MODEL NO. DEPTH INTAKE EXHAUST LIGHT FRONT ACCESS REAR EXHAUST MOTOR C. F. M. @ SHIPPING OVERALL FILTERS FILTERS FIXTURES DOOR DOOR DOOR FAN DIA. H.P. 3/8" S. P. WEIGHT

(A)

PLENUM9’-0” DOOR WIDTH

14’-0” W.I.D.

3’-6”

7’-8

” DO

OR H

EIGH

T

10’-0

” H.

O.A.

9’-0

” H.

I.D.

8’-6

” DO

OR H

EIGH

T

9’-0” DOOR WIDTH14’-0” W.I.D.

PLENUM

9’-0” DOOR WIDTH

14’-0” W.I.D.

3’-6”

7’-8

” DO

OR H

EIGH

T

10’-0

” H.

O.A.

9’-0

” H.

I.D.

14’-0” W.I.D.

PLENUM14’-0” W.I.D.

3’-6”

10’-0

” H.

O.A.

9’-0

” H.

I.D.

8’-6

” DO

OR H

EIGH

T

9’-0” DOOR WIDTH

14’-0” W.I.D.A

MODEL NO. DEPTH INTAKE EXHAUST LIGHT FRONT ACCESS REAR EXHAUST MOTOR C. F. M. @ SHIPPING OVERALL FILTERS FILTERS FIXTURES DOOR DOOR DOOR FAN DIA. H.P. 3/8" S. P. WEIGHT

(A)

A

©1999 BLEEKER BROS.

FULL-FEATURE

FULL-FEATURE

FULL-FEATURE

Page 24: BLEEKER DIGITAL CATALOG

Toll Free 800.421.1107 23

BLE

EK

ER

VSB-26 26'-2" 26 24 7-OT-5VT 1 PAIR ONE NONE 34" 3 14,500 6,000 VSB-28 28'-8" 26 24 11-OT-5VT 1 PAIR ONE NONE 34" 3 14,500 6,400 VSB-33 33'-8" 26 24 13-OT-5VT 1 PAIR TWO NONE 34" 3 14,500 7,300 VSB-38 38'-8" 26 24 15-OT-5VT 1 PAIR TWO NONE 34" 3 14,500 8,200

VAN FILTER BOOTHS

VDT-26 26’-2” 26 24 7 OT-5VT 1 PAIR ONE 1 PAIR 34" 3 14,500 6,300 VDT-28 28’-8” 26 24 11 OT-5VT 1 PAIR ONE 1 PAIR 34" 3 14,500 6,700 VDT-33 33’-8” 26 24 13 OT-5VT 1 PAIR TWO 1 PAIR 34" 3 14,500 7,600 VDT-38 38’-8” 26 24 15 OT-5VT 1 PAIR TWO 1 PAIR 34" 3 14,500 8,500

VAN REAR-DRIVE STYLE FILTER BOOTH MODEL

VAN DRIVE-THROUGH STYLE FILTER BOOTH MODEL

VRD-26 26'-2" 26 24 7-OT-5VT NONE ONE 1 PAIR 34" 3 14,500 6,000

VRD-28 28'-8" 26 24 11-OT-5VT NONE ONE 1 PAIR 34" 3 14,500 6,400

VRD-33 33'-8" 26 24 13-OT-5VT NONE TWO 1 PAIR 34" 3 14,500 7,300

VRD-38 38'-8" 26 24 15-OT-5VT NONE TWO 1 PAIR 34" 3 14,500 8,200

VAN SOLID-BACK STYLE FILTER BOOTH MODEL

MODEL NO. DEPTH INTAKE EXHAUST LIGHT FRONT ACCESS REAR EXHAUST MOTOR C. F. M. @ SHIPPING OVERALL FILTERS FILTERS FIXTURES DOOR DOOR DOOR FAN DIA. H.P. 3/8" S. P. WEIGHT

(A)

MODEL NO. DEPTH INTAKE EXHAUST LIGHT FRONT ACCESS REAR EXHAUST MOTOR C. F. M. @ SHIPPING OVERALL FILTERS FILTERS FIXTURES DOOR DOOR DOOR FAN DIA. H.P. 3/8" S. P. WEIGHT

(A)

MODEL NO. DEPTH INTAKE EXHAUST LIGHT FRONT ACCESS REAR EXHAUST MOTOR C. F. M. @ SHIPPING OVERALL FILTERS FILTERS FIXTURES DOOR DOOR DOOR FAN DIA. H.P. 3/8" S. P. WEIGHT

(A)

9’-0” DOOR WIDTH3’-6”

11’-0

” H.

O.A.

10’-0

” H.

I.D.

9’-0” DOOR WIDTH3’-6”

PLENUM3’-6”

11’-0

” H.

O.A.

9’-0” DOOR WIDTH

10’-0

” H.

I.D.

14’-0” W.I.D.

8’-8

” DO

OR H

EIGH

T

11’-0

” H.

O.A.

PLENUM

10’-0

” H.

I.D.

10’-0

” H.

I.D.

14’-0” W.I.D.

8’-8

” DO

OR H

EIGH

T

PLENUM 9’-0” DOOR WIDTH

9’-6

” DO

OR H

EIGH

T

14’-0” W.I.D.A

9’-6

” DO

OR H

EIGH

T

A

©1999 BLEEKER BROS.

FULL-FEATURE

FULL-FEATURE

FULL-FEATURE

FULL-FEATURE

A

Page 25: BLEEKER DIGITAL CATALOG

24 EMAIL: [email protected] www.BleekerBros.com

BLE

EK

ER

AUTO-TRUCK & TRUCK FILTER BOOTHS

AUTO-TRUCK & TRUCK SOLID-BACKFILTER BOOTHS

• This style is the most widely used in the truck painting industry.

• Entrance through filtered doors located at front of booth.

• Auto-truck filtered doors are 10’-0” wide x 11’-6” high.

• Truck filtered doors are 11’-0” wide x 14’-0” high.

• Solid back allows back of booth to be against a wall or other obstruction if necessary.

• Personnel doors are 3’-0” wide x 6’-8” high with 1/4” clear tempered glass.

SELECTING YOUR BOOTH STYLE

AUTO-TRUCK & TRUCK DRIVE-THROUGH FILTER BOOTHS

• This booth is recommended where adequate working area is available.

• Incorporates both filtered front doors and solid rear doors.

• Auto-truck filtered doors are 10’-0” wide x 11’-6” high.

• Truck filtered doors are 11’-0” wide x 14’-0” high.

• Auto-truck solid doors are 10’-0” wide x 10’-6” high.

• Truck solid doors are 11’-0” wide x 13’-6” high.

• Allows entrance or exit through either end of booth forbetter workflow, or movement of painted vehicles to flash-off or oven enclosure.

• Personnel doors are 3’-0” wide X 6’-8” high with 1/4” clear tempered glass.

AUTO-TRUCK & TRUCK REAR-DRIVEFILTER BOOTHS

• Rear drive style is also known as reverse flow.

• Entrance through solid doors at the rear of booth.

• Auto-truck solid doors are 10’-0” wide x 10’-6” high.

• Truck solid doors are 11’-0” wide x 13’-6” high.

• This booth is recommended when at least 3 feet of clearance can be given at the front of the booth to allow for air intake.

• The advantage of this booth is that the airborne dirt from leaks that inevitably develop around all booth entrance doors will pass directly into the exhaust chamber without passing over the newly painted vehicle.

• Personnel doors are 3’-0” wide x 6’-8” high with 1/4” clear tempered glass.

Page 26: BLEEKER DIGITAL CATALOG

BLEEKER BROS. Automotive stylebooths are available in two lightingarrangements to fit your budget andneeds.

FULL-FEATURE (as shown) is ourrecommended automotive stylebooth and includes sidelights, doorlimit switches and solenoid valve.

BASIC-FEATURE Lighting Layoutwithout vapor-tight lights, door limitswitches or solenoid valve. To orderadd “X” to model number.

FULL-FEATURE models are specifiedthroughout this catalog.

Toll Free 800.421.1107 25

BLE

EK

ER

AUTO-TRUCK & TRUCK FILTER BOOTHS

Features• All Industrial Paint Spray

Booths adhere to the Uniform Fire Code and the National Electrical Code. Always check local fire and electrical codes for special conditions that may prevail in your area.

• Open-Type Fluorescent Light Fixtures as listed are U.L. and C-U.L. approved, 4’ long, 4-tubes.

• Vapor-Tight Fluorescent Fixtures as listed are U.L. and C-U.L. approved, 4’-long, 4-tubes, adhering to Hazardous Area Class 1, Division 2 from the National Electrical Code.

• All Light Fixtures are placed on the outside of 1/4” Clear Tempered Glass, gasketed and locked in place in the working depth of the Booth.

• Fan Motors are 3-phase, 208/230/460 volt, 60 Hz.

• Light Fixtures are 120 volt.

• Solenoid Valve is single phase. Voltage must be stated (110/220 etc.).

• Fan Outlet: top is standard. Backor side outlet can be supplied butposition must be requested.

• Panels are skidded and banded for forklift handling.

• Fans, motors, filters, etc., are packaged but loose.

• Shipment by Public Carrier has special requirements. Contact Factory or Dealer.

GENERAL INFORMATION

DRIVE- THROUGH STYLEREAR-DRIVE STYLESOLID-BACK STYLE

FULL-FEATUREBLEEKER BOOTHPACKAGE

Includes:Fan & Motor

Exhaust Filters

Door Limit Switches

Solenoid Valve

Nuts & Bolts

Manometer

Light Fixtures

Assembly Instructions

Not Included:Tubes or Bulbs

Duct Package

Sprinkler Systems

Air Lines

Electrical Switches

Motor Starter

Attachment anchor fromBooth to Floor

Electrical Hook-Up

NOTESLighting quantity is very subjective.Adding or deducting the quantitiesof light fixtures can easily be madeto our booth arrangements withoutlosing the financial advantage ofpurchasing a packaged booth.

Contact Factory or Dealer for price adjustment

Booth dimensions and price are subject to change without notice.

Additional Features Available:• Conveyor Openings

• Explosion-proof Motors

• Working Depth Extensions

• Special Width or Height requirements

• Special Lighting Arrangements

• BLEEKER- CURE™ Infra-Red

• Recirculating Heat System Package available at additional cost

• Contact Factory or Dealer for price adjustment

Construction Feature:• 18-Gauge Steel Panels.

• Bolt Construction. Inside of Booth is smooth.

• Filter Cells are 20” X 20” X 3”

• Light Windows contain 1/4” clear tempered glass

• Fans are belt driven with enclosed belt guards.

• Blades are rigid-type, spark-resistant and di-electric.

• Spray Booth Panels rest on heavy duty 14-Gauge, Galvanized Floor Angles.

• Face Velocity exceeds code requirement of 100 F. P. M.

FULL-FEATURE

BASIC-FEATURE

FULL-FEATURE

Page 27: BLEEKER DIGITAL CATALOG

26 EMAIL: [email protected] www.BleekerBros.com

BLE

EK

ER

12’-0

A

ATSB-28 28'-8" 32 34 12-OT-2VT 1 PAIR ONE NONE 36" 5 18,500 7,000

ATSB-33 33'-8" 32 34 16-OT-2VT 1 PAIR TWO NONE 36" 5 18,500 7,500

ATSB-38 38'-8" 32 34 18-OT-2VT 1 PAIR TWO NONE 36" 5 18,500 8,500

ATSB-43 43'-8" 32 34 22-OT-2VT 1 PAIR TWO NONE 36" 5 18,500 10,000

AUTO-TRUCK FILTER BOOTHS

AUTO-TRUCK REAR-DRIVE STYLE FILTER BOOTH MODEL

AUTO-TRUCK DRIVE-THROUGH STYLE FILTER BOOTH MODEL

AUTO-TRUCK SOLID-BACK STYLE FILTER BOOTH MODEL

ATRD-28 28'-8" 32 34 12-OT-2VT NONE ONE 1 PAIR 36" 5 18,500 7,000

ATRD-33 33'-8" 32 34 16-OT-2VT NONE TWO 1 PAIR 36" 5 18,500 7,500

ATRD-38 38'-8" 32 34 18-OT-2VT NONE TWO 1 PAIR 36" 5 18,500 8,500

ATRD-43 43'-8" 32 34 22-OT-2VT NONE TWO 1 PAIR 36" 5 18,500 10,000

ATDT-28 28'-8" 32 34 12-OT-2VT 1 PAIR ONE 1 PAIR 36" 5 18,500 7,400

ATDT-33 33'-8" 32 34 16-OT-2VT 1 PAIR TWO 1 PAIR 36" 5 18,500 7,900

ATDT-38 38'-8" 32 34 18-OT-2VT 1 PAIR TWO 1 PAIR 36" 5 18,500 8,900

ATDT-43 43'-8" 32 34 22-OT-2VT 1 PAIR TWO 1 PAIR 36" 5 18,500 10,400

MODEL NO. DEPTH INTAKE EXHAUST LIGHT FRONT ACCESS REAR EXHAUST MOTOR C. F. M. @ SHIPPING OVERALL FILTERS FILTERS FIXTURES DOOR DOOR DOOR FAN DIA. H.P. 3/8" S. P. WEIGHT

(A)

MODEL NO. DEPTH INTAKE EXHAUST LIGHT FRONT ACCESS REAR EXHAUST MOTOR C. F. M. @ SHIPPING OVERALL FILTERS FILTERS FIXTURES DOOR DOOR DOOR FAN DIA. H.P. 3/8" S. P. WEIGHT

(A)

MODEL NO. DEPTH INTAKE EXHAUST LIGHT FRONT ACCESS REAR EXHAUST MOTOR C. F. M. @ SHIPPING OVERALL FILTERS FILTERS FIXTURES DOOR DOOR DOOR FAN DIA. H.P. 3/8" S. P. WEIGHT

(A)

A

15’-0” W.I.D.

3”-6”

PLENUM A

©1999 BLEEKER BROS.

FULL-FEATURE

FULL-FEATURE

FULL-FEATURE

Page 28: BLEEKER DIGITAL CATALOG

Toll Free 800.421.1107 27

BLE

EK

ER

BLE

EK

ER

TRUCK FILTER BOOTHS

TSB-34 34'-2" 56 42 18-OT-6VT 1 PAIR TWO NONE 42" 7 1/2 26,500 8,500

TSB-39 39'-2" 56 42 22-OT-6VT 1 PAIR TWO NONE 42" 7 1/2 26,500 9,750

TSB-44 44'-2" 56 42 26-OT-6VT 1 PAIR TWO NONE 42" 7 1/2 26,500 11,000

TSB-49 49'-2" 56 42 32-OT-6VT 1 PAIR TWO NONE 42" 7 1/2 26,500 12,250

TSB-54 54'-2" 56 42 34-OT-6VT 1 PAIR TWO NONE 42" 7 1/2 26,500 13,500

TRD-34 34'-2" 56 42 18-OT-6VT NONE TWO 1 PAIR 42" 7 1/2 26,500 8,500 TRD-39 39'-2" 56 42 22-OT-6VT NONE TWO 1 PAIR 42" 7 1/2 26,500 9,750 TRD-44 44'-2" 56 42 26-OT-6VT NONE TWO 1 PAIR 42" 7 1/2 26,500 11,000 TRD-49 49'-2" 56 42 32-OT-6VT NONE TWO 1 PAIR 42" 7 1/2 26,500 12,250 TRD-54 54'-2" 56 42 34-OT-6VT NONE TWO 1 PAIR 42" 7 1/2 26,500 13,500

TDT-34 34'-2" 56 42 18-OT-6VT 1 PAIR TWO 1 PAIR 42" 7 1/2 26,500 9,250 TDT-39 39'-2" 56 42 22-OT-6VT 1 PAIR TWO 1 PAIR 42" 7 1/2 26,500 10,500 TDT-44 44'-2" 56 42 26-OT-6VT 1 PAIR TWO 1 PAIR 42" 7 1/2 26,500 11,750 TDT-49 49'-2" 56 42 32-OT-6VT 1 PAIR TWO 1 PAIR 42" 7 1/2 26,500 13,000 TDT-54 54'-2" 56 42 34-OT-6VT 1 PAIR TWO 1 PAIR 42" 7 1/2 26,500 14,250

TRUCK REAR-DRIVE STYLE FILTER BOOTH MODEL

TRUCK DRIVE-THROUGH STYLE FILTER BOOTH MODEL

TRUCK SOLID-BACK STYLE FILTER BOOTH MODEL

MODEL NO. DEPTH INTAKE EXHAUST LIGHT FRONT ACCESS REAR EXHAUST MOTOR C. F. M. @ SHIPPING OVERALL FILTERS FILTERS FIXTURES DOOR DOOR DOOR FAN DIA. H.P. 3/8" S. P. WEIGHT

(A)

MODEL NO. DEPTH INTAKE EXHAUST LIGHT FRONT ACCESS REAR EXHAUST MOTOR C. F. M. @ SHIPPING OVERALL FILTERS FILTERS FIXTURES DOOR DOOR DOOR FAN DIA. H.P. 3/8" S. P. WEIGHT

(A)

MODEL NO. DEPTH INTAKE EXHAUST LIGHT FRONT ACCESS REAR EXHAUST MOTOR C. F. M. @ SHIPPING OVERALL FILTERS FILTERS FIXTURES DOOR DOOR DOOR FAN DIA. H.P. 3/8" S. P. WEIGHT

(A)

17Õ-0Ó H.O.IA.17’-0” H.O.IA.13’-6” (DOO HWEIGHT)Tj ET1231.252283.4 m1231.251607.75 l S 1 g1221391583.38497.75(FR.76 re 110..3921970232 m f* BT 6 0 0 61246.8814FR.76 Tm 0 0 0 1 k(11’-0” T)Tj75 0 0751312.4214FR.76 Tm((DOO WIDTH.)Tj ET12251556.88 m17251556.88 l 097.75144..4 m1831.25144..4 l S 1 g1221475142837458 -86.75 re 68.669214FR.76 m f* BT 6 0 0 61358 861367841 Tm 0 0 0 1 k[1(6’-0” WL)73.I.DA.)]TJ ET 1 g2045566 22621468.35 -52.92 re1657.2391367841 m f* BT 0 6- 6 02110.762180.226 Tm 0 0 0 1 k(17’-0” H.O.IA.)Tj ET 134 12 398.75 m 134 121613 l S 1 g2236.88154651 06.92-86641 re2110.7622-1.551 m f* BT 7 0 0 7225.4711511275 Tm 0 0 0 1 k(4’-0”))Tj ET2262.871505 m2414 121505 l S 1 g223659214-..75 1708 -8645 re23980811511275 m f* BT4..75 0 075 2366921484.26 Tm 0 0 0 1 k(PLENUM.)Tj ET4267.75141..4 m 236 12141..4 l S 1 g35915651503511124.91 -34. re2470..91484.26 m f* Q q 1 i 12 780 588 -768 re 12 780 m W n 0 792.06 612 -792 re W n BT /87 1 Tf 12 0 0 1233621651343741 Tm 0 0 0 1 k 0 Tc 0 Tw(A)

Page 29: BLEEKER DIGITAL CATALOG

28 EMAIL: [email protected] www.BleekerBros.com

BLE

EK

ER

TRUE DOWN-DRAFT BOOTHS

AUTO-TRUCK andTRUCK STYLE

AUTO and VAN STYLE

GENERAL INFORMATION

AIR FLOW

AIR FLOW

Additional Features Available• Conveyor openings

• Explosion-proof motors

• Working depth extensions

• Special width or height requirements

• Special lighting arrangements

• Contact factory or dealer for price adjustment.

Construction Features• 18-Gauge Steel Panels.

• Bolt Construction. Inside of booth is smooth.

• Filter cells are 20” X 20” X 3”

• Light windows contain 1/4” clear tempered glass

• Fans are belt driven with enclosed belt guards.

• Blades are rigid-type, spark-resistant and di-electric.

• Spray booth panels rest on heavyduty 14-gauge, galvanized floor angles.

NOTES

Booth dimensions and price are subject to change without notice.

Features• All industrial paint spray

booths adhere to the Uniform Fire Code and the National Electrical Code. Always check local fire and electrical codes for special conditions that may prevail in your area.

• Open-type fluorescent light fixtures as listed are U.L. and C-U.L. approved, 4’ long, 4-tubes(Tubes not included).

• Vapor-tight fluorescent fixtures as listed are U.L. and C-U.L. approved, 4’-long, 4-tubes, adhering to Hazardous Area Class 1, Division 2 from the National Electrical Code. (Tubes not included)

• All light fixtures are placed on the outside of 1/4” clear tempered glass, gasketed and locked in place in the working depth of the booth.

• Fan motors are 3-phase, 208/230/460 volt, 60 Hz.

• Light fixtures are 120 volt.

• Solenoid valve is single phase. Voltage must be stated (110/220 etc.)

• Fan outlet is engineered to fit pit configeration.

• Panels are skidded and banded for forklift handling.

• Fans, motors, filters, etc., are packaged but loose.

• Shipment by public carrier has special requirements. Contact factory or dealer.

The Down-draft booth isconsidered by many to be the mosteffective of all automotive designedpaint spray booths to accomplishthe following:

• Clean intake air travels from filtered plenum overhead, past the operator’s face, to exhaust filters.

• Less overspray potential on the material being painted.

• Less downdraft velocity required to move hazardous VOCs in a natural downward movement.

• Downward face velocity approximately 50 feet per minute.

• This style can accommodate two operators.

• This design comes in Solid-Back(DD) or Drive-Through (DDT) models.

NOTE

Air supply must be added to ALLoverhead plenum arrangements(heated or ambient). If higherexhaust air movement is required,a dual pit is recommended.

Advantages• Saves floor space.

• Exhaust fan can be located at theconvenience of user.

Disadvantages• Must have concrete pit.

• Limited exhaust air movement available.

• Must remove filters before washing down the booth.

Page 30: BLEEKER DIGITAL CATALOG

Toll Free 800.421.1107 29

BLE

EK

ER

VDD-25 25'-0" 10'-0" 9'-6" ONE ONE 8-OT/4-VT 60 28 1-34” 1-5 HP 17,150 5,000

VDD-30 30'-0" 10'-0" 9'-6" ONE ONE 10-OT/4-VT 75 34 1-42” 1-5 HP 21,435 5,800

VDD-35 35'-0" 10'-0" 9'-6" ONE ONE 12-OT/4-VT 90 40 1-42” 1-7.5 HP 25,900 6,700

VDDT-25 25'-0" 10'-0" 9'-6" TWO ONE 7-OT/5-VT 60 28 1-34” 1-5 HP 17,150 5,300

VDDT-30 30'-0" 10'-0" 9'-6" TWO ONE 9-OT/5-VT 75 34 1-42” 1-5 HP 21,435 6,100

VDDT-35 35'-0" 10'-0" 9'-6" TWO ONE 11-OT/5-VT 90 40 1-42” 1-7.5 HP 25,900 7,000

TRUE DOWN-DRAFT BOOTHS

ATDD-30 30'-0" 12’-0” 11’-6” ONE TWO 14-OT/4-VT 90 34 1-42” 1-5 HP 21,435 7,000

ATDD-35 35'-0" 12’-0” 11’-6” ONE TWO 16-OT/4-VT 102 40 1-42” 1-7.5 HP 25,900 8,000

ATDD-40 40'-0" 12’-0” 11’-6” ONE TWO 20-OT/4-VT 120 46 1-48” 1-7.5 HP 30,750 9,500

ATDDT-30 30'-0" 12’-0” 11’-6” TWO TWO 12-OT/6-VT 90 34 1-42” 1-5 HP 21,435 7,500

ATDDT-35 35'-0" 12’-0” 11’-6” TWO TWO 14-OT/6-VT 102 40 1-42” 1-7.5 HP 25,900 8,500

ATDDT-40 40'-0" 12’-0” 11’-6” TWO TWO 18-OT/6-VT 120 46 1-48” 1-7.5 HP 30,750 10,000

TDD-40 40'-0" 16'-0" 14'-0" ONE TWO 26-OT/4-VT 140 46 1-48” 1-7.5 HP 30,750 10,000

TDD-45 45'-0" 16'-0" 14'-0" ONE TWO 28-OT/4-VT 154 52 2-42” 2-3HP 33,130 11,500

TDD-50 50'-0" 16'-0" 14'-0" ONE TWO 34-OT/4-VT 175 58 2-42” 2-5 HP 42,870 12,500

TDDT-40 40'-0" 16'-0" 14'-0" TWO TWO 24-OT/6-VT 140 46 1-48” 1-7.5 HP 30,750 11,000

TDDT-45 45'-0" 16'-0" 14'-0" TWO TWO 26-OT/6-VT 154 52 2-42” 2-3 HP 33,130 12,500

TDDT-50 50'-0" 16'-0" 14'-0" TWO TWO 32-OT/6-VT 175 58 2-42” 2-5 HP 42,870 13,500

ADD-20 20'-0" 9’-0” 8’-6” ONE ONE 6-OT/4-VT 60 34 1-34” 1-3 HP 13,965 4,000

ADD-25 25'-0" 9’-0” 8’-6” ONE ONE 8-OT/4-VT 75 40 1-34” 1-5 HP 17,150 4,800

ADD-30 30'-0" 9’-0” 8’-6” ONE ONE 10-OT/4-VT 90 46 1-42” 1-5HP 21,435 5,300

ADDT-20 20'-0" 9’-0” 8’-6” TWO ONE 5-OT/5-VT 60 34 1-34” 1-3 HP 13,965 4,300

ADDT-25 25'-0" 9’-0” 8’-6” TWO ONE 7-OT/5-VT 75 40 1-34” 1-5 HP 17,150 5,100

ADDT-30 30'-0" 9’-0” 8’-6” TWO ONE 9-OT/5-VT 90 46 1-42” 1-5 HP 21,435 5,600

AUTO-TRUCK

TRUCK

AUTO

VAN

BC

A

BC

A

FRONTFront & back view fordrive-through stylebooths

SIDE

*See specificationsfor number of exhaust fans.

*

FRONT

Front & back viewfor drive-throughstyle booths

SIDE

BACK For singleentrance

BACK

For singleentrance

MODEL WORKING INSIDE DOOR ENTRANCE PERSONNEL LIGHT INTAKE EXHAUST EXHAUST MOTORS CFM SHIPPING NO. DEPTH (A) HEIGHT (B) HEIGHT (C) DOOR DOOR FIXTURES FILTERS FILTERS FANS H.P. @1/2” WEIGHT

11’-0” I.D AUTO-TRUCK16’-0” I.D. TRUCK

15’-0” I.D AUTO-TRUCK16’-0” I.D. TRUCK

3’-6”

DOOR 10’-0” W.I.D. DOOR 11’-0” W.I.D.

INSIDE WIDTH14’-0”

AUTO-TRUCKTRUCK

©1999 BLEEKER BROS.

MODEL WORKING INSIDE DOOR ENTRANCE PERSONNEL LIGHT INTAKE EXHAUST EXHAUST MOTORS CFM SHIPPING NO. DEPTH (A) HEIGHT (B) HEIGHT (C) DOOR DOOR FIXTURES FILTERS FILTERS FANS H.P. @1/2” WEIGHT

MODEL WORKING INSIDE DOOR ENTRANCE PERSONNEL LIGHT INTAKE EXHAUST EXHAUST MOTORS CFM SHIPPING NO. DEPTH (A) HEIGHT (B) HEIGHT (C) DOOR DOOR FIXTURES FILTERS FILTERS FANS H.P. @1/2” WEIGHT

MODEL WORKING INSIDE DOOR ENTRANCE PERSONNEL LIGHT INTAKE EXHAUST EXHAUST MOTORS CFM SHIPPING NO. DEPTH (A) HEIGHT (B) HEIGHT (C) DOOR DOOR FIXTURES FILTERS FILTERS FANS H.P. @1/2” WEIGHT

DOOR WIDTH 9’-0”

Page 31: BLEEKER DIGITAL CATALOG

30 EMAIL: [email protected] www.BleekerBros.com

BLE

EK

ER

SEMI-DOWN DRAFT BOOTHS

AUTO and VAN STYLE AUTO-TRUCK and TRUCKSTYLE

GENERAL INFORMATION

AIR SUPPLY

Additional Features Available• Conveyor Openings

• Explosion-proof Motors

• Working Depth Extensions

• Special Width or Height Requirements.

• Special Lighting Arrangements

• Contact Factory or Dealer for price adjustment

Construction Features:• 18-Gauge Steel Panels.

• Bolt Construction. Inside of Booth is smooth.

• Filter Cells are 20” X 20” X 3”

• Light Windows contain 1/4” ClearTempered Glass

• Fans are belt driven with enclosed belt guards.

• Blades are rigid-type, spark-resistant and di-electric.

• Spray Booth Panels rest on heavy duty 14-Gauge, GalvanizedFloor Angles.

NOTE

Booth dimensions and price are subject to change without notice.

Features• All Industrial Paint Spray

Booths adhere to the Uniform Fire Code and the National Electrical Code. Always check local fire and electrical codes for special conditions that may prevail in your area.

• Open-Type Fluorescent Light Fixtures as listed are U.L. andC-U.L. approved, 4’ long, 4-tubes. (Tubes not included.)

• Vapor-Tight Fluorescent Fixtures as listed are U.L. and C-U.L. approved, 4’-long, 4-tubes, adhering to Hazardous AreaClass 1, Division 2 from the National Electrical Code. (Tubes not included.)

• All Light Fixtures are placed on the outside of 1/4” Clear Tempered Glass, gasketed and locked in place in the working depth of the Booth.

• Fan Motors are 3-phase, 208/230/460 volt, 60 Hz.

• Light Fixtures are 120 volt.

• Solenoid Valve is single phase. Voltage must be stated (110/220, etc.).

• Panels are skidded and banded for forklift handling.

• Fans, motors, filters, etc., are packaged but loose.

• Shipment by Public Carrier has special requirements. Contact Factory or Dealer.

The Down-draft style booth isconsidered by many to be the mosteffective of all automotive designedpaint spray booths to accomplishthe following:

• Clean intake air travels from filtered plenum overhead, past the operator’s face, to exhaust filters.

• Less overspray potential on the material being painted.

• Less downdraft velocity required to move hazardous VOCs in a natural downward movement.

• Downward face velocity approximately 50 FPM.

• This style can accommodate two operators.

• This design is available in Solid - Back (SDS) or Drive-Through (SDT) models.

NOTEAir supply must be added to ALLoverhead plenum arrangements,heated or ambient.

Advantages• Easy exhaust filter maintenance

• No pit required

• This design will accept increased exhaust velocity.

Disadvantages• Requires additional floor space

• In certain situations, overspray could pass over paint operator’s legs.

AIR SUPPLY

Page 32: BLEEKER DIGITAL CATALOG

Toll Free 800.421.1107 31

BLE

EK

ER

SEMI-DOWN DRAFT BOOTHS

BC

A

FRONT

Front & back view for drive-through style booths

SIDE BACK

For single entrance

ASDS-20 20'-0" 9'-0" 8'-6" ONE ONE 4-OT/4-VT 50 44 2-24” 2-1.5 HP 13,110 4,500

ASDS-25 25'-0" 9'-0" 8'-6" ONE ONE 6-OT/4-VT 65 56 2-24” 2-2 HP 15,970 5,300

ASDS-30 30'-0" 9'-0" 8'-6" ONE ONE 8-OT/4-VT 75 68 2-24” 2-3 HP 18,670 5,800

ASDT-20 20'-0" 9'-0" 8'-6" TWO ONE 3-OT/5-VT 50 44 2-24” 2-1.5 HP 13,110 4,500

ASDT-25 25'-0" 9'-0" 8'-6" TWO ONE 5-OT/5-VT 65 56 2-24” 2-2 HP 15,970 5,300

ASDT-30 30'-0" 9'-0" 8'-6" TWO ONE 7-OT/5-VT 75 68 2-24” 2-3 HP 18,670 5,800

AUTO

VSDS-25 25'-0" 10'-0" 9'-6" ONE ONE 6-OT/4-VT 65 56 2-24” 2-2 HP 15,970 5,800

VSDS-30 30'-0" 10'-0" 9'-6" ONE ONE 8-OT/4-VT 75 68 2-24” 2-3 HP 18,670 6,600

VSDS-35 35'-0" 10'-0" 9'-6" ONE ONE 10-OT/4-VT 90 76 2-30” 2-2 HP 19,980 7,500

VSDT-25 25'-0" 10'-0" 9'-6" TWO ONE 5-OT/5-VT 65 56 2-24” 2-2 HP 15,970 6,100

VSDT-30 30'-0" 10'-0" 9'-6" TWO ONE 7-OT/5-VT 75 68 2-24” 2-3 HP 18,670 6,900

VSDT-35 35'-0" 10'-0" 9'-6" TWO ONE 9-OT/5-VT 90 76 2-30” 2-2 HP 19,980 7,800

VAN

ATSDS-30 30'-0" 12’-0” 11’-6” ONE TWO 12-OT/4-VT 65 34 2-30” 2-2 HP 19,980 7,500

ATSDS-35 35'-0" 12’-0” 11’-6” ONE TWO 14-OT/4-VT 75 40 2-30” 2-3 HP 24,440 8,500

ATSDS-40 40'-0" 12’-0” 11’-6” ONE TWO 18-OT/4-VT 90 46 2-30” 2-5HP 29,990 10,000

ATSDT-30 30'-0" 12’-0” 11’-6” TWO TWO 10-OT/6-VT 65 34 2-30” 2-2 HP 19,980 8,000

ATSDT-35 35'-0" 12’-0” 11’-6” TWO TWO 12-OT/6-VT 75 40 2-30” 2-3 HP 24,440 9,000

ATSDT-40 40'-0" 12’-0” 11’-6” TWO TWO 16-OT/6-VT 90 46 2-30” 2-5 HP 29,990 10,500

AUTO-TRUCK

TSDS-40 40'-0" 16'-0" 14'-0" ONE TWO 26-OT/4-VT 120 84 2-42” 2-3 HP 33,130 10,000

TSDS-45 45'-0" 16'-0" 14'-0" ONE TWO 28-OT/4-VT 138 90 2-42” 2-3 HP 33,130 11,200

TSDS-50 50'-0" 16'-0" 14'-0" ONE TWO 34-OT/4-VT 150 96 2-42” 2-5 HP 42,870 12,500

TSDT-40 40'-0" 16'-0" 14'-0" TWO TWO 24-OT/6-VT 120 84 2-42” 2-3 HP 33,130 10,000

TSDT-45 45'-0" 16'-0" 14'-0" TWO TWO 26-OT/6-VT 138 90 2-42” 2-3 HP 33,130 11,200

TSDT-50 50'-0" 16'-0" 14'-0" TWO TWO 32-OT/6-VT 150 96 2-42” 2-5 HP 42,870 12,500

TRUCKMODEL WORKING INSIDE DOOR ENTRANCE PERSONNEL LIGHT INTAKE EXHAUST EXHAUST MOTORS CFM SHIPPING NO. DEPTH (A) HEIGHT (B) HEIGHT (C) DOOR DOOR FIXTURES FILTERS FILTERS FANS H.P. @1/2” WEIGHT

4’

MODEL WORKING INSIDE DOOR ENTRANCE PERSONNEL LIGHT INTAKE EXHAUST EXHAUST MOTORS CFM SHIPPING NO. DEPTH (A) HEIGHT (B) HEIGHT (C) DOOR DOOR FIXTURES FILTERS FILTERS FANS H.P. @1/2” WEIGHT

MODEL WORKING INSIDE DOOR ENTRANCE PERSONNEL LIGHT INTAKE EXHAUST EXHAUST MOTORS CFM SHIPPING NO. DEPTH (A) HEIGHT (B) HEIGHT (C) DOOR DOOR FIXTURES FILTERS FILTERS FANS H.P. @1/2” WEIGHT

MODEL WORKING INSIDE DOOR ENTRANCE PERSONNEL LIGHT INTAKE EXHAUST EXHAUST MOTORS CFM SHIPPING NO. DEPTH (A) HEIGHT (B) HEIGHT (C) DOOR DOOR FIXTURES FILTERS FILTERS FANS H.P. @1/2” WEIGHT

3’ 0”15’-0” I.D AUTO-TRUCK16’-0” I.D. TRUCK

10’-0” I.D11’-0” I.D.

AUTO-TRUCKTRUCK

C B

3’ 6”

A3’ 0”

©1999 BLEEKER BROS.

Page 33: BLEEKER DIGITAL CATALOG

32 EMAIL: [email protected] www.BleekerBros.com

BLE

EK

ER

EXHAUST PLENUMS

DUAL EXHAUST PLENUMAUTOMOTIVE-TYPE

INDUSTRIALEXHAUST PLENUM

B

A

C

E

D

C

B

A

GENERAL INFORMATION

Exhaust Plenums are often used in H-2 Occupancy rooms or areawhere there is a high concentrationof noxious fumes. The Plenumscan also be adapted to the usersown spray room conditions.Always check with local fire andelectrical codes before proceedingwith this type of installation.

Features• All Standard Exhaust Plenums

adhere to the Uniform Fire Code and the National Electrical Code. Always check local fire and electrical codes for special conditions that may prevail in your area.

• Fan Motors are totally enclosed, 3-phase 208/230/460volt, 60 HZ.

• Panels are skidded and banded for forklift handling.

• Fans, motors, filters, etc. are packaged, but loose.

• Shipment by Public Carrier has special requirements. Contact Factory or Dealer.

BLEEKER BOOTHPACKAGE

Includes:Fan & TEFC Motor

Exhaust Filters

Manometer

Nuts & Bolts

Filter Grids

Assembly Instructions

Not Included:Sprinkler Systems

Air Lines

Electrical Switches

Motor Starter

Solenoid valve

Electrical Hook-Up

Attachment anchors fromBooth to Floor

Additional Features Available• Explosion-Proof Motors

• Special Width or Height requirement

• Contact Factory or Dealer for price adjustment.

Construction Features• 18-Gauge Steel Panels

• Bolt Construction. Inside of Booth is smooth.

• Filter Cells are 20” X 20” X 3”

• Plenum Panels rest on heavy duty 14-Gauge Galvanized Floor Angles.

• Fans are belt driven with enclosed belt guards.

• Blades are rigid-type, spark-resistant and di-electric.

NOTES

Plenum specifications and price aresubject to change without notice.

This arrangement may requireexplosion-proof motors. Contact aknowledgeable dealer or factory.

Page 34: BLEEKER DIGITAL CATALOG

Toll Free 800.421.1107 33

BLE

EK

ER

EXHAUST PLENUMS

EP-4-7 4'-4" 7'-0" 2'-2" 8 1-18" 3/4 3,635 300 EP-4-8 4'-4" 8'-0" 2'-2" 8 1-18" 1 4,290 900 EP-4-10 4'-4" 10'-0" 2'-8" 10 1-24" 1 6,260 1,100 EP-5-7 5'-4" 7'-0" 2'-8" 12 1-24" 1 6,260 1,100 EP-5-8 5'-4" 8'-0" 2'-8" 12 1-24" 1 6,260 450 EP-5-10 5'-4" 10'-0" 2'-8" 12 1-24" 1 6,260 1,200 EP-6-7 6'-4" 7'-0" 2'-8" 12 1-24" 1 6,260 1,000 EP-6-8 6'-4" 8'-0" 2'-8" 12 1-24" 1 6,260 1,050 EP-6-10 6'-4" 10'-0" 2'-8" 15 1-24" 1 1/2 7,200 1,300 EP-8-7 8'-4" 7'-0" 2'-8" 16 1-24" 1 1/2 7,200 1,075 EP-8-8 8'-4" 8'-0" 2'-8" 16 1-24" 2 8,500 1,175 EP-8-10 8'-4" 10'-0" 3'-2" 20 1-30" 1 1/2 9,815 1,400 EP-10-7 10'-4" 7'-0" 2'-8" 20 1-24" 2 8,500 1,550 EP-10-8 10'-4" 8'-0" 3'-2" 20 1-30" 1 1/2 9,815 1,650 EP-10-10 10'-4" 10'-0" 3'-2" 25 1-30" 3 13,180 1,900 EP-10-12 10'-4" 12'-0" 3'-2" 30 1-30" 5 15,785 2,150 EP-12-7 12'-4" 7'-0" 3'-2" 28 1-30" 2 11,180 1,800 EP-12-8 12'-4" 8'-0" 3'-2" 28 1-30" 3 13,180 2,000 EP-12-10 12'-4" 10'-0" 3'-2" 35 1-30" 5 15,785 2,300 EP-12-12 12'-4" 12'-0" 3'-8" 42 1-34" 5 18,280 2,650 EP-14-7 14'-4" 7'-0" 3'-2" 32 1-30" 3 13,180 2,050 EP-14-8 14'-4" 8'-0" 3'-2" 32 1-30" 5 15,785 2,150 EP-14-10 14'-4" 10'-0" 3'-8" 40 1-34" 5 18,280 2,450 EP-14-12 14'-4" 12'-0" 4'-2" 48 1'-42" 5 23,505 2,900 EP-14-12HV 14'-4" 12'-0" 3'-2" 48 2'-30" 3 26,360 3,000 EP-16-7 16'-4" 7'-0" 3'-2" 36 1-30" 5 15,785 2,200 EP-16-8 16'-4" 8'-0" 3'-8" 36 1-34" 3 15,350 2,350 EP-16-10 16'-4" 10'-0" 4'-2" 45 1'-42" 5 23,505 2,975 EP-16-12 16'-4" 12'-0" 4'-2" 54 1'-42" 5 23,505 3,300 EP-16-12HV 16'-4" 12'-0" 3'-2" 54 2'-30" 3 26,360 3,400 EP-18-7 18'-4" 7'-0" 3'-8" 40 1-34" 3 15,350 2,350 EP-18-8 18'-4" 8'-0" 4'-2" 40 1-42" 3 19,275 2,650 EP-18-10 18'-4" 10'-0" 4'-2" 50 1-42" 5 23,505 3,150 EP-18-12 18'-4" 12'-0" 4'-2" 60 1-42" 7 1/2 27,610 3,500 EP-18-12HV 18'-4" 12'-0" 3'-2" 60 2-30" 5 31,570 3,500 EP-20-7 20'-4" 7'-0" 4'-2" 44 1-42" 3 19,275 1,600 EP-20-7HV 20'-4" 7'-0" 3'-2" 44 2-30" 2 22,360 1,550 EP-20-8 20'-4" 8'-0" 4'-2" 44 1-42" 5 23,505 1,750 EP-20-10 20'-4" 10'-0" 4'-2" 55 1-42" 7 1/2 27,610 2,000 EP-20-10HV 20'-4" 10'-0" 3'-2" 55 2-30" 5 31,570 2,100 EP-20-12 20'-4" 12'-0" 4'-8" 66 1-48" 7 1/2 33,185 2,450 EP-22-7 22'-4" 7'-0" 4'-2" 52 1-42" 3 19,275 1,750 EP-22-8 22'-4" 8'-0" 4'-2" 52 1-42" 5 23,505 1,850 EP-22-8HV 22'-4" 8'-0" 3'-2" 52 2-30" 3 26,360 1,850 EP-22-10 22'-4" 10'-0" 4'-8" 65 1-48" 5 28,745 2,300 EP-22-12 22'-4" 12'-0" 4'-8" 78 1-48" 7 1/2 33,185 2,550 EP-24-7 24'-4" 7'-0" 4'-2" 56 1-42" 5 23,505 1,800 EP-24-8 24'-4" 8'-0" 4'-2" 56 1-42" 7 1/2 27,610 2,000 EP-24-8HV 24'-4" 8'-0" 3'-2" 56 2-30" 5 31,570 2,050 EP-24-10 24'-4" 10'-0" 4'-8" 70 1-48" 7 1/2 33,185 2,450 EP-24-12 24'-4" 12'-0" 3'-8" 84 2-36" 5 38,920 3,100 EP-26-7 26'-4" 7'-0" 4'-2" 60 1-42" 5 23,505 1,950 EP-26-7HV 26'-4" 7'-0" 3'-2" 60 2-30" 3 26,360 2,000 EP-26-8 26'-4" 8'-0" 3'-2" 60 2-30" 5 31,570 2,100 EP-26-10 26'-4" 10'-0" 4'-8" 75 1-48" 7 1/2 33,185 2,550 EP-26-12 26'-4" 12'-0" 3'-8" 90 2-36" 5 38,920 3,100 EP-28-7 28'-4" 7'-0" 4'-2" 64 1-42" 7 1/2 27,610 2,100 EP-28-7HV 28'-4" 7'-0" 3'-2" 64 2-30" 5 31,570 2,200 EP-28-8 28'-4" 8'-0" 3'-2" 64 2-30" 5 31,570 2,300 EP-28-10 28'-4" 10'-0" 3'-8" 80 2-36" 5 38,920 3,100 EP-28-12 28'-4" 12'-0" 3'-8" 96 2-42" 5 47,010 3,400 EP-30-7 30'-4" 7'-0" 3'-2" 68 2-30" 3 26,360 2,250 EP-30-8 30'-4" 8'-0" 3'-2" 68 2-30" 5 31,570 2,350 EP-30-10 30'-4" 10'-0" 3'-8" 85 2-36" 5 38,920 3,200 EP-30-12 30'-4" 12'-0" 4'-2" 102 2-42" 5 47,010 3,500

MODEL WIDTH HEIGHT DEPTH FILTER EXHAUST MOTOR C. F. M SHIPPING NO OVERALL (A) OVERALL (B) OVERALL (C) CELLS FAN H. P. @ 1/4" S. P. WEIGHT

INDUSTRIAL EXHAUST PLENUMS

DE-14-10 14’-4” 10’-0” 3’-8” 10’-0” 8’-0” 18 34” 2 12,500 1,450DE-14-11 14’-4” 11’-0” 3’-8” 10’-0” 9’-0” 24 34” 3 14,500 1,550 DE-15-13 15’-4” 13’-0” 3’-8” 11’-0” 11’-0” 34 36” 5 18,500 1,700 DE-16-17 16’-4” 17’-0” 4’-2” 12’-0” 15’-0” 42 42” 71/2 26,500 2,300

DUAL EXHAUST PLENUMS - AUTOMOTIVE TYPE

©1999 BLEEKER BROS.

MODEL WIDTH HEIGHT DEPTH INSIDE INSIDE FILTER EXHAUST MOTOR C. F. M SHIPPING NO OVERALL (A) OVERALL (B) OVERALL (C) WIDTH (D) HEIGHT (E) CELLS FAN H. P. @ 3/8" S. P. WEIGHT

Page 35: BLEEKER DIGITAL CATALOG

34 EMAIL: [email protected] www.BleekerBros.com

BLE

EK

ER

CEP-4-7 4’-0” 7’-0” 2’-0” 3’-7” 8 2 18” 1 1/2 3,800 350

CEP-4-8 4’-0” 8’-0” 2’-0” 3’-7” 8 2 18” 1 1/2 3,800 400

CEP-5-7 5’-0” 7’-0” 2’-6” 3’-8” 12 4 24” 2 6,490 450

CEP-5-8 5’-0” 8’-0” 2’-6” 3’-8” 12 4 24” 2 6,490 500

CEP-6-7 6’-0” 7’-0” 2’-6” 3’-8” 12 4 24” 2 6,490 475

CEP-6-8 6’-0’ 8’-0” 2’-6” 3’-8” 12 4 24” 2 6,490 525

CEP-8-7 8’-0” 7’-0” 2’-6” 3’-8” 16 4 24” 2 6,490 600

CEP-8-8 8’-0” 8’-0” 3’-0” 4’-2” 16 6 30” 3 9,740 750

CEP-10-7 10’-0” 7’-0” 3’-0” 4’-2” 20 6 30” 3 9,740 800

CEP-10-8 10’-0” 8’-0” 3’-0” 4’-2” 20 6 30” 3 9,740 850

CEP-10-10 10’-0” 10’-0” 3’-6” 5’-5” 25 8 34" 5 14,445 1,050

CEP-10-12 10’-0” 12’-0” 3’-6” 5’-5” 30 8 34" 5 14,445 1,100

CEP-12-7 12’-0” 7’-0” 3’-6” 5’-5” 28 8 34" 5 14,445 1,000

CEP-12-8 12’-0” 8’-0” 3’-6” 5’-5” 28 8 34" 5 14,445 1,050

CEP-12-10 12’-0” 10’-0” 3’-6” 5’-5” 35 8 34" 5 14,445 1,100

CEP-12-12 12’-0” 12’-0” 4’-0” 5’-8” 42 12 42" 7 1/2 21,775 1,600

CEP-14-7 14’-0” 7’-0” 3’-6” 5’-5” 32 8 34" 5 14,445 1,100

CEP-14-8 14’-0” 8’-0” 3’-6” 5’-5” 32 8 34" 5 14,445 1,150

CEP-14-10 14’-0” 10’-0” 4’-0” 5’-8” 40 12 42" 7 1/2 21,775 1,700

CEP-14-12 14’-0” 12’-0” 4’-0” 5’-8” 48 12 42" 7 1/2 21,775 1,750

CEP-16-7 16’-0” 7’-0” 3’-6” 5’-5” 36 8 34" 5 14,445 1,200

CEP-16-8 16’-0” 8’-0” 3’-6” 5’-5” 36 8 34" 5 14,445 1,250

CEP-16-10 16’-0” 10’-0” 3’-0” 4’-2” 45 12 2-30" 2-3 H.P. 19,480 1,600

CEP-16-12 16’-0” 12’-0” 3’-6” 5’-5” 54 16 2-34" 2-5 H.P. 28,890 1,900

CEP-18-7 18’-0” 7’-0” 3’-6” 5’-5” 40 8 36" 5 14,825 1,500

CEP-18-8 18’-0” 8’-0” 3’-0” 4’-2” 40 12 2-30" 2-3 H.P. 19,480 1,600

CEP-18-10 18’-0” 10’-0” 3’-6” 5’-5” 50 16 2-34" 2-5 H.P. 28,890 1900

CEP-18-12 18’-0” 12’-0” 3’-6” 5’-5” 60 16 2-34" 2-5 H.P. 28,890 2,000

CEP-20-7 20’-0” 7’-0” 3’-0” 4’-2” 44 12 2-30" 2-3 H.P. 19,480 1,800

CEP-20-8 20’-0” 8’-0” 3’-0” 4’-2” 44 12 2-30" 2-3 H.P. 19,480 1,850

CEP-20-10 20’-0” 10’-0” 3’-6” 5’-5” 55 16 2-34" 2-5 H.P. 28,890 2,100

CEP-20-12 20’-0” 12’-0” 3’-6” 5’-5” 66 16 2-34" 2-5 H.P. 28,890 2,250

POWDER CONTAINMENT EXHAUST PLENUMS

BLEEKER BOOTHPACKAGE

Includes:Fan & Motor

Manometers (2)

Pressure Switches (2)

Pre-Filters

Pocket Filters

Final Filters

Nuts & Bolts

Assembly Instructions

Not Included:Tubes or Bulbs

Duct Package

Sprinkler System

Motor Starters

Electrical Switches orHook-ups

Air Line

Attachment anchor fromBooth to Floor

MODEL WIDTH HEIGHT DEPTH UPPER FILTER FINAL EXHAUST MOTOR C.F.M. SHIPPINGNO. A B C PLENUM CELLS FILTERS FAN H.P. @ 1” S.P. WEIGHT

GENERAL INFORMATION

NOTES

Not to be used for wet painting orblasting.

Booth dimensions and price aresubject to change without notice.

Features• All Powder Containment

Exhaust Plenums adhere to theUniform Fire Code and the National Electrical Code. Always check local fire and electrical codes for special conditions that may prevail in your area.

• Fan Motors are totally enclosed, 3-phase 208/230/460 volt, 60 HZ .(Add explosion proof motor ifrequired by local code. Contact factory or dealer for price adjustment.)

• Panels are skidded and banded for forklift handling.

• Fans, motors, filters, etc. are packaged, but loose.

• Shipment by Public Carrier has special requirements. Contact Factory or Dealer.

©1999 BLEEKER BROS.

Construction Features• 18-Gauge Steel Panels

• Bolt Construction. Inside of Booth is smooth.

• Filter Cells are 20” X 20” X 3”

• Plenum Panels rest on heavy duty 14-Gauge Galvanized Floor Angles.

• Fans are belt driven with enclosed belt guards.

• Blades are rigid-type, spark-resistant and di-electric.

Page 36: BLEEKER DIGITAL CATALOG

Toll Free 800.421.1107 35

BLE

EK

ER

RECIRCULATING HEAT SYSTEMS

GENERAL INFORMATION

RHS-200 14'-0" 9'-0" 60° 200,000 18" 1 2460 9” 1/3 400 1200

RHS-300 14'-0" 10'-0" 80° 360,000 18" 1 1/2 3300 9” 1/2 400 2000

Low temperature Recirculating HeatSystems are designed to force-dry aproduct in a temperature-controlledenvironment, such as a spray boothor drying room. The heat systemincludes a recirculating fan whichconveys air through an indirect gas-fired duct furnace, which isthermostatically controlled. Therecirculating air does not come incontact with the open flame becauseit is conveyed through an indirect heatexchanger and therefore may be usedfor spray booth and drying roomenvironments.

Recirculating blower withfresh air intake damper

Return air plenum

Exhaust blower

Furnace

Filteredintakeplenum

Flue pipe

Recirculating Heat Systemsdesigned to fit BLEEKER BROS.Automotive Style or Drying RoomEquipment

FOR LOW NOX HEATERS,CONSULT FACTORY

If closure is longer than 15 feet,order additional duct.

Contact factory or dealer for priceadjustment.

Specifications and prices are subjectto change without notice.

Not Included:• 6’ Flue piping

• Exhaust fan and exhaust duct.(Purchase with drying room)

• Additional recirculating duct

• Motor controls for all motors

• Temperature recorder

Prewiredcontrol panel

PRE-WIRE CONTROL PANEL

Simplifies and lowers the cost ofwiring. It also provides the paintbooth supervisor with a centrallylocated control center. Supplied andprewired in a NEMA-12 enclosure.(Not including motor starters)

MODEL WIDTH HEIGHT TEMP BTU RECIRCULATING H.P. C.F.M. EXHAUST H.P. C.F.M. SHIPPINGNO. A B RISE BLOWER BLOWER WEIGHT

©1999 BLEEKER BROS.

Features Included• Horizontal heating unit with

Temperature Rise as indicated. Indirect Natural Gas fired heat exchanger, including all gas controls. Electric ignition pre-wired AGA Certified.

• Duct Thermostat

• Recirulating Duct work sized for 15 ft. long enclosures.

• Prewired Control Panel NEMA-1 with necessary switches.

• Assembly hardware for the aboveHeat and Ductwork.

Page 37: BLEEKER DIGITAL CATALOG

BLE

EK

ER

36 EMAIL: [email protected] www.BleekerBros.com

BLEEKERENCLOSUREPACKAGE

Includes:Fan & Motor

Intake Filters

Light Fixtures

Nuts & Bolts

Assembly Instructions

Not Included:Tubes or Bulbs

Duct Package

Sprinkler Systems

Air Lines

Electrical Switches

Motor Starters

Electrical Hook-Up

Attachment Anchors fromBooth to Floor

Infra- red Units

Recirculating Gas Heater

GENERAL INFORMATION

Additional features available

• Conveyor openings

• Explosion proof motors

• Working depth extension

• Special width or height requirements and special lighting arrangements

• Contact dealer or factory for priceadjustment.

NOTES

Enclosure dimensions and price aresubject to change without notice.

For Infra-Red Design, refer toBleeker-Cure™ Package.

For Recirculating Gas heatingSystem, refer to Bleeker Bros.Recirculating Heater.

• This type of enclosure can be used as a separate room or as anadd-on to an automotive type drive-through booth. End wall is included to enable use as a standalone enclosure. Heat can be added at extra cost to speed drying time.

• All standard automotive type flash-off enclosures adhere to the Uniform Fire Code and the National Electric Code. Always check local fire and electrical codes for special conditions that may prevail in your area.

• All automotive type flash-off enclosures are of gable type design.

• Fluorescent light fixtures as listedare U.L and C-U.L. approved, 4’ long, 4 tube open type.

• All light fixtures are placed on the outside of 1/4 “ clear tempered glass, gasketed and locked in place.

• Fan motors are three phase, 208/230/460 volt, 60 Hz.

• Panels are skidded and banded for fork lift handling. Fans, motors, filters, etc., are packagedbut loose. Shipment by public carrier has special requirements contact factory or dealer.

Construction Features

• 18 gauge steel panels.

• Bolt construction. Inside of enclosure is smooth.

• Filter cells are 20”x20”x3”.

• Light windows contain 1/4” clear tempered glass — 16”x 54”.

• Fans are belt driven with enclosed belt guards. Blades are rigid type and are nonsparking and di-electric.

• Enclosure panels rest on heavy duty 14 gauge galvanized floor angles.

• Personnel doors dimensions, refer to appropriate booth.

• Solid exit door dimensions, refer to appropriate drive-through booth.

FLASH-OFF ENCLOSURES

Page 38: BLEEKER DIGITAL CATALOG

BLE

EK

ER

Toll Free 800.421.1107 37

FLASH-OFF ENCLOSURES

MODEL NO. DEPTH WIDTH HEIGHT INTAKE LIGHT PERSONNEL EXIT EXHAUST MOTOR . SHIPPING (A) (B) (C) FILTER FIXTURE DOOR DOOR FAN H. P WEIGHT LBS.

AF0-15 15'-0" 14'-0" 9'-0" 4 2-OT-FLUR 1 ONE PAIR 12" 1/3 3200

AF0-20 20'-0" 14'-0" 9'-0" 4 2-OT-FLUR 1 ONE PAIR 12" 1/3 4200

AF0-22-1/2 22'-6" 14'-0" 9'-0" 4 2-OT-FLUR 1 ONE PAIR 12" 1/3 4700

AF0-25 25'-0" 14'-0" 9'-0" 4 2-OT-FLUR 1 ONE PAIR 12" 1/3 5100

AF0-30 30'-0" 14'-0" 9'-0" 4 2-OT-FLUR 1 ONE PAIR 12" 1/3 6000

MODEL NO. DEPTH WIDTH HEIGHT INTAKE LIGHT PERSONNEL EXIT EXHAUST MOTOR . SHIPPING (A) (B) (C) FILTER FIXTURE DOOR DOOR FAN H. P WEIGHT LBS.

VF0-22-1/2 22'-6" 14'-0" 10'-0" 6 2-OT-FLUR 1 ONE PAIR 12" 1/3 5100

VF0-25 25'-0" 14'-0" 10'-0" 6 2-OT-FLUR 1 ONE PAIR 12" 1/3 5500

VF0-30 30'-0" 14'-0" 10'-0" 6 2-OT-FLUR 1 ONE PAIR 12" 1/3 6500

VF0-35 35'-0" 14'-0" 10'-0" 6 2-OT-FLUR 1 ONE PAIR 12" 1/3 7400

MODEL NO. DEPTH WIDTH HEIGHT INTAKE LIGHT PERSONNEL EXIT EXHAUST MOTOR . SHIPPING (A) (B) (C) FILTER FIXTURE DOOR DOOR FAN H. P WEIGHT LBS.

ATF0-25 25'-0" 15'-0" 12'-0" 8 2-OT-FLUR 1 ONE PAIR 18" 1/2 6500

ATF0-30 30'-0" 15'-0" 12'-0" 8 2-OT-FLUR 1 ONE PAIR 18" 1/2 7200

ATF0-35 35'-0" 15'-0" 12'-0" 8 2-OT-FLUR 1 ONE PAIR 18" 1/2 8000

ATF0-40 40'-0" 15'-0" 12'-0" 8 2-OT-FLUR 1 ONE PAIR 18" 1/2 9000

MODEL NO. DEPTH WIDTH HEIGHT INTAKE LIGHT PERSONNEL EXIT EXHAUST MOTOR . SHIPPING (A) (B) (C) FILTER FIXTURE DOOR DOOR FAN H. P WEIGHT LBS.

TF0-30 30'-0" 16'-0" 16'-0" 14 2-OT-FLUR 1 ONE PAIR 18" 1/2 7,500

TF0-35 35'-0" 16'-0" 16'-0" 14 2-OT-FLUR 1 ONE PAIR 18" 1/2 7,800

TF0-40 40'-0" 16'-0" 16'-0" 14 2-OT-FLUR 1 ONE PAIR 18" 1/2 8,600

TF0-45 45'-0" 16'-0" 16'-0" 14 2-OT-FLUR 1 ONE PAIR 18" 1/2 11,000

TF0-50 50'-0" 16'-0" 16'-0" 14 2-OT-FLUR 1 ONE PAIR 18" 1/2 12,500

ENCLOSURE TO BE USED WITH AUTO-DRIVE THROUGH (or as a stand-alone enclosure)

ENCLOSURE TO BE USED WITH VAN-DRIVE THROUGH (or as a stand-alone enclosure)

ENCLOSURE TO BE USED WITH AUTO-TRUCK-DRIVE THROUGH(or as a stand-alone enclosure)

ENCLOSURE TO BE USED WITH TRUCK-DRIVE THROUGH(or as a stand-alone enclosure)

B

C

A

©1999 BLEEKER BROS.

Page 39: BLEEKER DIGITAL CATALOG

Typical True Down-Draft (ADD)design with BLEEKER-CURE™ BoothPackage

Typical Cross-Draft (ASB)design with BLEEKER-CURE™Package

Typical Semi Down-Draft(ASDS) design with BLEEKER-CURE™ BoothPackage

Typical Automotive Flash-off(AFO) design with BLEEKER-CURE™ Curing EnclosurePackage

BLE

EK

ER

38 EMAIL: [email protected] www.BleekerBros.com

BLEEKER-CURE™ INFRA-RED BOOTH and ENCLOSURE PACKAGE

NOTES: On Cross Flow styles, ASB-26, etc.,deduct the plenum depth to arrive atthe true working depth, whichshould correspond the BLEEKER-CURE Package model number.

Curing Enclosures are to be used forInfra-red curing only- no painting.All other models may be used forboth coating and curing.

Bleeker-Cure Infra-red Packages includes a 2-speed exhaust fan motor.

Auto and Van Cure Booth Packagesfeature all horizontal Infra-red units.

Auto-Truck and Truck Cure BoothPackages feature Vertical SidewallInfra-red units.

BLEEKER-CURE™BOOTH PACKAGE

Includes:NEMA 12 Control Panel

Infra-red units with mountingframes

Motor & heating controls

Not included:

Exhaust duct work

Additional electrical controls,such as oven timers, recordersand safety controls.

AUTOMOTIVE–STYLE BLEEKER-CURE™PACKAGE WITH INFRA-RED UNITS The BLEEKER-CURE™ Package is an integrated design that fits allautomotive-style booths and flash-off enclosures. This design has beenengineered to fit a variety of applications that can be incorporated in bothpainting and infrared drying.

For technical information concerning size, quantity of lights, filters, motors,fans, etc., refer to the appropriate booth design, i.e., cross-draft, down-draft,flash-off enclosures, etc. Lighting arrangement and quantity is adjusted toaccommodate proper infra-red design.

To order an integrated BLEEKER-CURE™ booth or enclosure, order the boothmodel number, such as an ASB-18 or TFO-45, along with the model number ofthe integrated BLEEKER-CURE™ package.

To choose the proper BOOTH or ENCLOSUREPACKAGE, use the following formula:

A. Select the size, (width and height) and type (auto, van, auto-truck, truck, cross-flow, down draft, etc.) of booth or enclosure needed.

B. Determine the length of booth or enclosure required. This measurement will correspond with the number on the BLEEKER-CURE™ package.

C. Booth or Enclosure + Bleeker-Cure Package= Infrared System

Page 40: BLEEKER DIGITAL CATALOG

BLE

EK

ER

Toll Free 800.421.1107 39

Bleeker-Cure™ Package for Booth

This package can be integrated into all styles.• Solid-back • Rear drive

• Drive through • True Down Draft

• Semi Down-Draft • Cross Flow

BLEEKER-CURE™ INFRA-RED BOOTH and ENCLOSURE PACKAGE

AUTO CURE BOOTH PACKAGE

Bleeker-Cure™ Package for Enclosures

Our enclosures are engineered for each specific style aslisted.

ACB-15 14'-0" 15'-0" 3 2 2 20,000

ACB-20 14'-0" 20'-0" 3 4 4 34,000

ACB-22.5 14'-0" 22'-6" 3 4 4 34,000

ACB-25 14'-0" 25'-0" 4 4 4 36,000

ACB-30 14'-0" 30'-0" 5 6 6 52,000

VAN CURE BOOTH PACKAGE

VCB-22.5 14'-0" 22'-6" 3 4 4 34,000

VCB-25 14'-0" 25'-0" 4 4 4 36,000

VCB-30 14'-0" 30'-0" 5 6 6 52,000

VCB-35 14'-0" 35'-0" 7 6 6 56.000

TRUCK CURE BOOTH PACKAGE

TCB-30 16'-0" 30'-0" 0 16 0 48,000

TCB-35 16'-0" 35'-0" 0 18 0 54,000

TCB-40 16'-0" 40'-0" 0 22 0 66,000

TCB-45 16'-0" 45'-0" 0 24 0 72.000

TCB-50 16'-0" 50'-0" 0 28 0 84,000

AUTO-TRUCK CURE BOOTH PACKAGE

ATCB-25 15'-0" 25'-0" 0 12 0 36,000

ATCB-30 15'-0" 30'-0" 0 16 0 48,000

ATCB-35 15'-0" 35'-0" 0 18 0 54,000

ATCB-40 15'-0" 40'-0" 0 22 0 66,000

* Contact an Electrical Engineer to determine your electrical needs. This is determined by the type ofvoltage supplied and additional AMPS beyond the specified WATTS as shown.

AUTO CURE ENCLOSURE PACKAGE

ACE-15 14'-0" 15'-0" 3 2 2 20,000

ACE-20 14'-0" 20'-0" 3 4 4 34,000

ACE-22.5 14'-0" 22'-6" 3 4 4 34,000

ACE-25 14'-0" 25'-0" 4 4 4 36,000

ACE-30 14'-0" 30'-0" 5 6 6 52,000

VAN CURE ENCLOSURE PACKAGE

VCE-22.5 14'-0" 22'-6" 3 4 4 34,000

VCE-25 14'-0" 25'-0" 4 4 4 36,000

VCE-30 14'-0" 30'-0" 5 6 6 52,000

VCE-35 14'-0" 35'-0" 7 6 6 56.000

TRUCK CURE ENCLOSURE PACKAGE

TCE-30 16'-0" 30'-0" 0 16 0 48,000

TCE-35 16'-0" 35'-0" 0 18 0 54,000

TCE-40 16'-0" 40'-0" 0 22 0 66,000

TCE-45 16'-0" 45'-0" 0 24 0 72.000

TCE-50 16'-0" 50'-0" 0 28 0 84,000

AUTO-TRUCK CURE ENCLOSURE PACKAGE

ATCE-25 15'-0" 25'-0" 0 12 0 36,000

ATCE-30 15'-0" 30'-0" 0 16 0 48,000

ATCE-35 15'-0" 35'-0" 0 18 0 54,000

ATCE-40 15'-0" 40'-0" 0 22 0 66,000

Infra-Red Lamp with Cover Infra-Red Lamp without Cover

MODEL NO. WIDTH WORKING 2000 3000 4000 *TOTALDEPTH (A) WATTS WATTS WATTS WATTS

MODEL NO. WIDTH WORKING 2000 3000 4000 *TOTALDEPTH (A) WATTS WATTS WATTS WATTS

MODEL NO. WIDTH WORKING 2000 3000 4000 *TOTALDEPTH (A) WATTS WATTS WATTS WATTS

MODEL NO. WIDTH WORKING 2000 3000 4000 *TOTALDEPTH (A) WATTS WATTS WATTS WATTS

MODEL NO. WIDTH WORKING 2000 3000 4000 *TOTALDEPTH (A) WATTS WATTS WATTS WATTS

MODEL NO. WIDTH WORKING 2000 3000 4000 *TOTALDEPTH (A) WATTS WATTS WATTS WATTS

MODEL NO. WIDTH WORKING 2000 3000 4000 *TOTALDEPTH (A) WATTS WATTS WATTS WATTS

MODEL NO. WIDTH WORKING 2000 3000 4000 *TOTALDEPTH (A) WATTS WATTS WATTS WATTS

©1999 BLEEKER BROS.

Page 41: BLEEKER DIGITAL CATALOG

40 EMAIL: [email protected] www.BleekerBros.com

AIR MAKE-UP UNITS

GENERAL INFORMATION

Standard FeaturesInclude:

• Galvanized type zinc coated steel casing

• Lifting lugs on large units

• Channel based or curb cap type

• Centrifugal blower assembly

• Permanent lubricated bearings

• Open drip-proof motor

• Terminal strip

• Remote control panel with summer/ winter switch

• Wide range high capacity line burner

• Various gas manifold arrangements

• High temperature safety controls

• Electronic flame safety control

• Electric spark pilot ignition

• Burner and blower service switches

• Main fused disconnect

• Adjustable motor mount

Optional Features Available• Filter section with cleanable filters

• Adjustable drive

• Motorized discharge or intake damper with safety interlocks

• Low temperature shutdown with bypass timer

• ETL label

NOTE:

The above options arerecommended for optimalperformance.

The need to replace exhausted air in apaint finishing area is a must whenconsidering the following issues: Forevery cubic foot of air dischargedfrom your spray booth, ovens and/orother equipment, an equal amount ofair must find its way into the areathrough doors, windows or otheropenings. This can affect the airquality throughout the whole plantand perhaps brings in dust or otherparticles, which could contaminatethe painted parts. If the painting areais sealed off it will greatly add to thestatic pressure, thereby lowering theamount of exhausted air to the pointwhere you would no longer be incompliance with paint booth airmovement codes. In addition,employee safety, comfort, andproductivity may be affected by thetype of air supply provided. Proper airtemperature provides better workingconditions and can improveproductivity. Certain choices must bemade when deciding on the type ofAir Make-Up Unit that is best for yourspecific application.

AMBIENT

Using outside supply fan only.Uses spray booth supply fans orblower. (Consult your dealer orFactory)

HEATED

Packaged Air Make-up or AirSupply Unit with single or dual(optional) blower.

Select Area to be Supplied• Dedicated to each booth

• Space heating for finishing area

• For entire plant

Other factors affecting type ofAir Supply to be selected

• Static Pressure

• Temperature Rise

• Humidity

• Location

• Accessories

• Ductwork or Supply Plenum required

BLEEKER BROS. Direct-fired AirMake-Up units address the manyconditions that may be present foryour particular needs.

Additional Optional featuresavailable:

• High efficiency filters

• Discharge arrangements

• Clogged filter switch with indicator light

• Vibration isolators (hanging or floor mount)

• Special coatings and materials

• Circuit analyzer

• Insulated casing FIA, FM, IRI or other special controls

• Two speed motors

• Roof curbs

• Weatherproofing construction

• Special burner area with insulated liner

Contact Factory or Dealer for priceadjustment for all optional features.

NOTES

AMU dimensions and prices aresubject to change without notice.

BLE

EK

ER

Page 42: BLEEKER DIGITAL CATALOG

BLE

EK

ER

Toll Free 800.421.1107 41

AIR MAKE-UP UNITS

Note: C.F.M., M.B.H. and H.P. range is calculated at 80°rise with 1/2” external static pressure

Specifications are subject to change. Consult Factory or Dealer for current data. Data stated in inches.

AMU-10 6,000-10,000 518-864 3-7.5 82 60 54 8.5 40.5 2 56 18.5 19.13 12.5 22.13

AMU-15 10,000-15,000 864-1296 5-15 82 60 54 8.5 40.5 2 56 18.94 25 12.5 23

AMU-20 15,000-24,000 1296-2074 7.5-20 100 79 58 8.5 46.5 2 76 21.75 31.5 15.5 31.5

AMU-30 24,000-36,000 2074-3110 15-25 100 88 66 10.5 52.5 2 80 24.88 37 15.5 37

SINGLE BLOWERS

AMU-40 36,000-48,000 3110-4147 36-48 100 156 66 10.5 52.5 2 152 23 34.5 19.5 96

AMU-50 48,000-58,000 4147-5011 25-30 100 156 66 10.5 52.5 2 152 24.88 37 15.5 104

AMU-70 58,000-70,000 5011-6048 30-40 126 184 75 11.5 59.5 2 180 22 43.19 18.5 116

AMU-90 70,000-92,000 6048-7949 40-75 126 184 75 11.5 59.5 2 180 22 43.19 15.5 122

MODEL CFM INPUT H.P. A B C D E F G H J K LRANGE MBH RANGE RANGE

DUAL BLOWERS

MODEL CFM INPUT H.P. A B C D E F G H J K LRANGE MBH RANGE RANGE

PLAN VIEW

SIDE VIEW

PLAN VIEWSIDE VIEW

FOR LOW NOX HEATERS, CONSULT FACTORY.

E

D

A

C

J

H

1 1/2F

G B

K

©1999 BLEEKER BROS.

L

Page 43: BLEEKER DIGITAL CATALOG

TYPICAL AIR SUPPLY ARRANGEMENTSB

LEEK

ER

42 EMAIL: [email protected] www.BleekerBros.com

HORIZONTALROOF MOUNT

HORIZONTALBELOW ROOFMOUNT

HORIZONTALBOOTH MOUNT

AMBIENTNONHEATEDAIR SUPPLY

VERTICALSIDEMOUNT

Page 44: BLEEKER DIGITAL CATALOG

BLE

EK

ER

Toll Free 800.421.1107 43

CUSTOM DOWNDRAFT GRINDING ENCLOSURES

Recirculatingfactory air

The capture or containment of the grinding and dustparticles has been successfully addressed with theBLEEKER BROS. Downdraft Grinding Enclosure. Thisdesign deals with the following:

• Constructed to fit the physical size of the product

• Air movement and/or velocity based on the number ofapplications and/or expected volume of particulates.

• The need or desirability to recirculate factory air or to use outside ambient air

• Call our Engineering Department for your special requirements.

• Not recommended for metal cleaning or grinding

CUSTOM GRINDINGENCLOSURES

FIBERGLASS INDUSTRY ANDSPECIAL APPLICATIONS

Boat, spa and recreational vehicle manufacturers have allprospered with the advent and growth of the fiberglassindustry.

Their special needs includes:

• Greater floor space• Heavy residue with the chopper application• Distinct and often offensive odor• Capture or containment of the grinding particles and

dust on the finished products

Using outsideambient air

Page 45: BLEEKER DIGITAL CATALOG

BLE

EK

ER

44 EMAIL: [email protected] www.BleekerBros.com

BENCH WATER WASH BOOTHS

• All Bench Water Wash Booths adhere to the Uniform Fire Code and the National Electrical Code. Always check local fire and electrical codes for special conditions that may prevail in your area.

• Incandescent Light Fixtures as listed are U.L. approved, 300 wattExplosion-proof, adhering to Hazardous Class 1, Division 1 from the National Electrical Code.

• Vapor-Tight Fluorescent Fixtures are U.L. and C-U.L. approved, 4’-long, 4-tube, adher to Hazardous Area Class 1, Division 2 from the National Electrical Code.

• All Light Fixtures are placed on the outside of 1/4” Clear Tempered Glass, gasketed and locked in place in the working depth of the Booth.

• Fan and Pump Motors are 3-phase, 230/460 volt, 60 Hz., explosion-proof.

• Fan Outlet: Top is standard.Back or side outlet can besupplied, but position must berequested.

• Panels are skidded and banded for forklift handling.

BLEEKER BOOTHPACKAGE

Includes:Fan & Motor

Pump

Solenoid Valve

Pump Motor

Light Fixtures

Nuts & Bolts

Assembly Instructions

Not Included:Tubes or Bulbs

Duct Package

Sprinkler Systems

Air Lines

Electrical Switches

Motor Starters

Electrical Hook-Up

Attachment Anchors fromBooth to Floor

• Fans, motors, filters, etc. arepackaged, but loose.

• Shipment by Public Carrier has special requirements. Contact Factory or Dealer.

Additional Features Available:

• Working Depth Extensions

• Special Width or Height Requirements

• Special Lighting Arrangements

• Contact Factory or Dealer for price adjustment.

• Pump mounted on right side unless ordered for left side, at no additional cost.

• Face Velocity exceeds 150 FPM.

NOTE

Booth dimensions and price aresubject to change without notice.

Face Velocities and static pressurewill change due to job site ductrequirements (offsets, duct length,pump capacity G.P.M.)

GENERAL INFORMATION

Typical V-T IncandescentLighting Arrangement, 4’ wide only.

Typical V-T Fluorescent LightingArrangement, 5’ wide and larger.

Page 46: BLEEKER DIGITAL CATALOG

BLE

EK

ER

Toll Free 800.421.1107 45

BENCH WATER WASH BOOTHS

CONSTRUCTION FEATURES

• 18-Gauge Galvanized Steel Washer Panels.

• 12-Gauge Galvanized Tank.

• Grating is 1” Galvanized Steel.

• Bolt Construction. Inside of Booth is smooth.

• Light windows contain 1/4” Clear Tempered Glass

• Fans are belt driven with belts totally enclosed.

• Blades are rigid-type and are spark-resistant and di-electric.

• Pump screens

MODEL WIDTH WORKING DEPTH TANK LIGHT EXHAUST MOTOR C. F. M.@ FACE PUMP PUMP. SHIPPINGNO. I. D. DEPTH OVERALL OVERALL FIXTURE FAN H. P. 1" S. P. VELOCITY G. P. M. H. P WEIGHT

(A) (B) (C)

BW-4-7 4'-0" 3'-0" 5'-8" 6'-10" 1-VT-INCD 1-24" 2 3000 180 175 3 2300

BW-5-7 5'-0" 3'-0" 5'-8" 7'-10" 1-VT-FLUR 1-24" 2 3750 180 200 3 2400

BW-6-7 6'-0" 3'-0" 5'-8" 8'-10" 1-VT-FLUR 1-24" 2 4500 180 228 3 2500

BW-8-7 8'-0" 4'-0" 6'-8" 10'-10" 1-VT-FLUR 1-24" 2 6000 180 284 5 2800

BW-10-7 10'-0" 4'-0" 6'-8" 12'-10" 1-VT-FLUR 1-24" 3 7500 180 340 5 3000

BW-12-7 12'-0" 4'-0" 7'-2" 14'-10" 1-VT-FLUR 1-30" 3 9000 180 396 5 3200©1999 BLEEKER BROS.

Page 47: BLEEKER DIGITAL CATALOG

PUMP WATER-WASH BOOTHSB

LEEK

ER

46 EMAIL: [email protected] www.BleekerBros.com

Construction Features

• 18-Gauge Galvanized SteelWasher Panels

• 12-Gauge Galvanized SteelTank

• Bolt Construction. Inside ofBooth is smooth.

• Light Windows contain 1/4”Clear Tempered Glass

• Fans are belt driven with beltstotally enclosed.

• Blades are rigid-type, spark-resistant and di-electric.

• Pump mounted on right sideunless left side is specified.

• Spray Booth Working DepthPanels rest on heavy duty 14-Gauge Galvanized Floor Angles.

• Face Velocity exceeds coderequirement of 100 F.P.M.

• See specifications for FaceVelocity of individual Booths.

Features

• All Pump Water-Wash Booths adhere to the Uniform Fire Code and the National Electrical Code. Always check local fire and electrical codes for special conditions that may prevail in your area.

• Vapor-Tight Fluorescent Fixtures are U.L. and C-U.L. approved and .95 AMP, 4’-long, 4-tube, adhere to Hazardous Area Class1, Division 2 from the National Electrical Code.

• All Light Fixtures are placed on the outside of 1/4” Clear Tempered Glass, gasketed and locked in place in the working depth of the Booth.

• Fan Motors are: 3-phase, 208/230/460 volt, 60 Hz..

• Light Fixtures are 120 volt.

• Solenoid Valve is single phase. Voltage must be stated (110/ 220 etc.).

• Fan Outlet: top is standard. Backor side outlet can be supplied butposition must be requested.

• Panels are skidded and banded for forklift handling.

• Fans, motors, filters, etc., are packaged but loose.

• Shipment by Public Carrier has special requirements. Contact Factory or Dealer.

GENERAL INFORMATION

Typical V-T flur. lightingarrangement for under10’ W.D.

Typical O-T flur.lighting arrangementfor 10’ W.D. & deeper

Additional Features Available

• Conveyor Openings

• Explosion-proof Motors

• Working Depth Extensions

• Special Width or Height Requirements

• Special Lighting Arrangements

• Sludge Removal System

• Can be shipped sub-assembledat additional cost.

• Contact Factory or Dealer for price adjustment.

• Booth dimensions and prices are subject to change without notice.

(F)

(A)

(B)

(C)

(E)

(D)

PUMPR.H.

Page 48: BLEEKER DIGITAL CATALOG

BLE

EK

ER

Toll Free 800.421.1107 47

PUMP WATER-WASH BOOTHS

WW-4-7-5 4'-0" 6'-10" 5'-0" 4'-4" 10' 10'-2" 6'-10" 1-VT-FLUR 175 3 24" 2 4500 @ 1.2 S.P. 160 2,100

WW-4-7-7 4'-0" 6'-10" 7'-0" 4'-4" 10' 12'-2" 6'-10" 1-VT-FLUR 175 3 24" 2 4500 @ 1.2 S.P. 160 2,150

WW-4-8-5 4'-0" 7'-10" 5'-0" 4'-4" 10' 10'-2" 6'-10" 1-VT-FLUR 175 3 24" 2 4500 @ 1.2 S.P. 140 2,200

WW-4-8-7 4'-0" 7'-10" 7'-0" 4'-4" 10' 12'-2" 6'-10" 1-VT-FLUR 175 3 24" 2 4500 @ 1.2 S.P. 140 2,250

WW-5-7-5 5'-0" 6'-10" 5'-0" 5'-4" 10' 10'-2" 7'-10" 1-VT-FLUR 200 3 24" 2 5800 @ 1.125 S.P. 165 2,300

WW-5-7-7 5'-0" 6'-10" 7'-0" 5'-4" 10' 12'-2" 7'-10" 1-VT-FLUR 200 3 24" 2 5800 @ 1.125 S.P. 165 2,350

WW-5-8-5 5'-0" 7'-10" 5'-0" 5'-4" 10' 10'-2" 7'-10" 1-VT-FLUR 200 3 24" 2 5800 @ 1.125 S.P. 145 2,400

WW-5-8-7 5'-0" 7'-10" 7'-0" 5'-4" 10' 12'-2" 7'-10" 1-VT-FLUR 200 3 24" 2 5800 @ 1.125 S.P. 145 2,450

WW-6-7-5 6'-0" 6'-10" 5'-0" 6'-4" 10' 10'-2" 8'-10" 1-VT-FLUR 228 3 24" 2 6500 @ 1.0 S.P. 150 2,500

WW-6-7-7 6'-0" 6'-10" 7'-0" 6'-4" 10' 12'-2" 8'-10" 1-VT-FLUR 228 3 24" 2 6500 @ 1.0 S.P. 150 2,550

WW-6-8-5 6'-0" 7'-10" 5'-0" 6'-4" 10' 10'-2" 8'-10" 1-VT-FLUR 228 3 24" 2 6500 @ 1.0 S.P. 135 2,600

WW-6-8-7 6'-0" 7'-10" 7'-0" 6'-4" 10' 12'-2" 8'-10" 1-VT-FLUR 228 3 24" 2 6500 @ 1.0 S.P. 135 2,650

WW-8-7-5 8'-0" 6'-10" 5'-0" 8'-4" 10' 10'-2" 10'-10" 1-VT-FLUR 284 3 24" 3 8155 @ 1.0 S.P. 145 3,100

WW-8-7-7 8'-0" 6'-10" 7'-0" 8'-4" 10' 12'-2" 10'-10" 1-VT-FLUR 284 5 24" 3 8155 @ 1.0 S.P. 145 3,200

WW-8-8-5 8'-0" 7'-10" 5'-0" 8'-4" 10' 10'-2" 10'-10" 1-VT-FLUR 284 5 24" 3 8155 @ 1.0 S.P. 125 3,200

WW-8-8-7 8'-0" 7'-10" 7'-0" 8'-4" 10' 12'-2" 10'-10" 1-VT-FLUR 284 5 24" 3 8155 @ 1.0 S.P. 125 3,300

WW-8-10-5 8'-0" 9'-10" 5'-0" 8'-4" 10' 10'-2" 10'-10" 1-VT-FLUR 284 5 30" 5 12125 @ 125 S.P. 150 3,400

WW-8-10-7 8'-0" 9'-10" 7'-0" 8'-4" 10' 12'-2" 10'-10" 2-VT-FLUR 284 5 30" 5 12125 @ 125 S.P. 150 3,500

WW-10-7-7 10'-0" 6'-10" 7'-0" 10-4" 10' 12'-2" 12'-10" 2-VT-FLUR 340 5 30" 3 10450 @ .875 S.P. 145 3,700

WW-10-7-10 10'-0" 6'-10" 10'-0" 10-4" 10' 15'-2" 12'-10" 2-OT-FLUR 340 5 30" 3 10450 @ .875 S.P. 145 3,900

WW-10-8-7 10'-0" 7'-10" 7'-0" 10-4" 10' 12'-2" 12'-10" 2-VT-FLUR 340 5 30" 5 13190 @ 1.0 S.P. 165 3,800

WW-10-8-10 10'-0" 7'-10" 10'-0" 10-4" 10' 15'-2" 12'-10" 2-OT-FLUR 340 5 30" 5 13190 @ 1.0 S.P. 165 4,000

WW-10-10-7 10'-0" 9'-10" 7'-0" 10-4" 10' 12'-2" 12'-10" 2-VT-FLUR 340 5 34" 5 13750 @ 1.125 S.P. 135 4,000

WW-10-10-10 10'-0" 9'-10" 10'-0" 10-4" 10' 15'-2" 12'-10" 3-OT-FLUR 340 5 34" 5 13750 @ 1.125 S.P. 135 4,200

WW-12-7-7 12'-0" 6'-10" 7'-0" 12'-4" 10' 12'-2" 14'-10" 2-VT-FLUR 396 5 34" 5 13750 @ 1.125 S.P. 160 4,650

WW-12-7-10 12'-0" 6'-10" 10'-0" 12'-4" 10' 15'-2" 14'-10" 3-OT-FLUR 396 5 34" 5 13750 @ 1.125 S.P. 160 4,900

WW-12-8-7 12'-0" 7'-10" 7'-0" 12'-4" 10' 12'-2" 14'-10" 2-VT-FLUR 396 5 34" 5 13750 @ 1.125 S.P. 140 4,800

WW-12-8-10 12'-0" 7'-10" 10'-0" 12'-4" 10' 15'-2" 14'-10" 3-OT-FLUR 396 5 34" 5 13750 @ 1.125 S.P. 140 5,050

WW-12-10-7 12'-0" 9'-10" 7'-0" 12'-4" 10' 12'-2" 14'-10" 3-VT-FLUR 396 5 42" 7 1/2 18120 @1.250 S.P. 150 5,100

WW-12-10-10 12'-0" 9'-10" 10'-0" 12'-4" 10' 15'-2" 14'-10" 3-OT-FLUR 396 5 42" 7 1/2 18120 @1.250 S.P. 150 5,250

WW-14-7-7 14'-0" 6'-10" 7'-0" 15'-0" 10' 12'-2" 16'-10" 3-VT-FLUR 452 7 1/2 36" 5 14825 @ 1.0 S.P. 150 5,100

WW-14-7-10 14'-0" 6'-10" 10'-0" 15'-0" 10' 15'-2" 16'-10" 4-OT-FLUR 452 7 1/2 36" 5 14825 @ 1.0 S.P. 150 5,350

WW-14-8-7 14'-0" 7'-10" 7'-0" 15'-0" 10' 12'-2" 16'-10" 3-VT-FLUR 452 7 1/2 36" 5 14825 @ 1.0 S.P. 130 5,200

WW-14-8-10 14'-0" 7'-10" 10'-0" 15'-0" 10' 15'-2" 16'-10" 4-OT-FLUR 452 7 1/2 36" 5 14825 @ 1.0 S.P. 130 5,450

WW-14-10-7 14'-0" 9'-10" 7'-0" 15'-0" 10' 12'-2" 16'-10" 3-VT-FLUR 452 7 1/2 42" 7 1/2 17500 @ 1.25 S.P. 125 5,300

WW-14-10-10 14'-0" 9'-10" 10'-0" 15'-0" 10' 15'-2" 16'-10" 4-OT-FLUR 452 7 1/2 42" 7 1/2 17500 @ 1.25 S.P. 125 5,600

WW-16-7-7 16'-0" 6'-10" 7'-0" 17'-0" 10' 12'-2" 18'-10" 3-VT-FLUR 508 7 1/2 42" 7 1/2 19000 @ 1.2 S.P. 165 5,800

WW-16-7-10 16'-0" 6'-10" 10'-0" 17'-0" 10' 15'-2" 18'-10" 3-OT-FLUR 508 7 1/2 42" 7 1/2 19000 @ 1.2 S.P. 165 6,100

WW-16-8-7 16'-0" 7'-10" 7'-0" 17'-0" 10' 12'-2" 18'-10" 3-VT-FLUR 508 7 1/2 42" 7 1/2 19000 @ 1.2 S.P. 145 6,000

WW-16-8-10 16'-0" 7'-10" 10'-0" 17'-0" 10' 15'-2" 18'-10" 4-OT-FLUR 508 7 1/2 42" 7 1/2 19000 @ 1.2 S.P. 145 6,300

WW-16-10-7 16'-0" 9'-10" 7'-0" 17'-0" 10' 12'-2" 18'-10" 4-VT-FLUR 508 7 1/2 42" 7 1/2 19000 @ 1.2 S.P. 120 6,800

WW-16-10-10 16'-0" 9'-10" 10'-0" 17'-0" 10' 15'-2" 18'-10" 5-OT-FLUR 508 7 1/2 42" 7 1/2 19000 @ 1.2 S.P. 120 7,100

WW-18-7-7 18'-0" 6'-10" 7'-0" 19'-0" 10' 12'-2" 20'-10" 4-VT-FLUR 564 10 42" 7 1/2 20200 @1.125 S.P. 155 6,900

WW-18-7-10 18'-0" 6'-10" 10'-0" 19'-0" 10' 15'-2" 20'-10" 4-OT-FLUR 564 10 42" 7 1/2 20200 @1.125 S.P. 155 7,200

WW-18-8-7 18'-0" 7'-10" 7'-0" 19'-0" 10' 12'-2" 20'-10" 4-VT-FLUR 564 10 42" 7 1/2 20200 @1.125 S.P. 135 7,000

WW-18-8-10 18'-0" 7'-10" 10'-0" 19'-0" 10' 15'-2" 20'-10" 4-OT-FLUR 564 10 42" 7 1/2 20200 @1.125 S.P. 135 7,300

WW-18-10-7 18'-0" 9'-10" 7'-0" 19'-0" 10' 12'-2" 20'-10" 4-VT-FLUR 564 10 42" 10 24920 @ 1.05 S.P. 135 7,800

WW-18-10-10 18'-0" 9'-10" 10'-0" 19'-0" 10' 15'-2" 20'-10" 5-OT-FLUR 564 10 42" 10 24920 @ 1.05 S.P. 185 8,100

WW-20-7-10 20'-0" 6'-10" 10'-0" 21'-0" 10' 15'-2" 22'-10" 5-OT-FLUR 585 10 42" 7 1/2 21000 @ 1.10 S.P. 150 7,400

WW-20-7-12 20'-0" 6'-10" 12'-0" 21'-0" 10' 17'-2" 22'-10" 6-OT-FLUR 585 10 42" 7 1/2 21000 @ 1.10 S.P. 150 7,800

WW-20-8-10 20'-0" 7'-10" 10'-0" 21'-0" 10' 15'-2" 22'-10" 5-OT-FLUR 585 10 42" 7 1/2 21000 @ 1.10 S.P. 130 7,600

WW-20-8-12 20'-0" 7'-10" 12'-0" 21'-0" 10' 17'-2" 22'-10" 6-OT-FLUR 585 10 42" 7 1/2 21000 @1.10 S.P. 130 8,000

WW-20-10-10 20'-0" 9'-10" 10'-0" 21'-0" 10' 15'-2" 22'-10" 6-OT-FLUR 585 10 42" 10 26000 @1.125 S.P. 130 8,800

WW-20-10-12 20'-0" 9'-10" 12'-0" 21'-0" 10' 17'-2" 22'-10" 7-OT-FLUR 585 10 42" 10 26000 @1.125 S.P. 130 9,400

MODEL WIDTH HEIGHT WORKING WORKING WASHER DEPTH TANK LIGHTS PUMP PUMP EXHAUST EXHAUST C. F. M. FACE SHIPPING NO. I. D. I. D. DEPTH I. D. DEPTH HEIGHT OVERALL WIDTH NO. & CAPACITY MOTOR FAN FAN VELOCITY WEIGHT

(A) (B) (C) WIDTH OVERALL (E) OVERALL TYPE G. P. M. H.P. MOTOROVERALL (D) (F) H.P.

©1999 BLEEKER BROS.

Page 49: BLEEKER DIGITAL CATALOG

BLE

EK

ER

48 EMAIL: [email protected] www.BleekerBros.com

PUMPLESS WATER-WASH BOOTHS

Bleeker Bros. manufactures acomplete line of Pumpless Water-Wash Spray Booths whichincorporate a Pumpless WashSection. It has all the features of apump-style Water Wash Booth,without a pump, including a visiblewater curtain. This style may requireadditional maintenance to maintainproper water curtain.

Features:• All Pumpless Water-Wash

Industrial Spray Booths adhere to the Uniform Fire Code and the National Electrical Code. Always check local and fire andelectrical codes for special conditions that may prevail in your area.

• Open-Type Fluorescent Light Fixtures as listed are U.L.& CU.L.approved, 4'-long, 4 tube.

• Vapor-Tight Fluorescent Fixtures are U.L. & C-U.L. approved, 4' long, 4 tube, adhering to Hazardous Area Class 1, Division2 from the National Electrical Code.

• All Light Fixtures are placed on the outside of 1/4" Clear Tempered Glass, gasketed and locked in place in the Working Depth of the booth.

• Fan Motor is totally enclosed, 3 phase, 208/230/460 volt, 60 HZ..

• Light Fixtures are 120 volt.

• Solenoid Valve is single phase. Voltage must be stated (110/220)etc.

BLEEKER BOOTH PACKAGE

Includes:Vaneaxial Exhaust Blower

Nuts & Bolts

Motor

Solenoid Valve

Assembly Instructions

Manometer

Light Fixtures

Taper Joint for DuctConnection

Not Included:Tubes or Bulbs

Duct Package

Sprinkler Systems

Air Lines

Electrical Switches

Motor Starters

Electrical Hook-Up

Attachment Anchors fromBooth to Floor

Typical Open-type Fluorescent LightingArrangement for Working Depth 10'-0"and deeper 4-tube.

GENERAL INFORMATION• Panels are skidded and banded

for forklift handling.

• Fans, motors, filters, etc., are packaged, but loose.

• Shipment by Public Carrier has special requirements. Contact Factory or Dealer.

• Booths can be shipped sub-assembled, ready for installation, at an additional cost.

Additional Features Available

• Conveyor Openings

• Special Width or Height Requirements

• Explosion-Proof Motors

• Special Lighting Arrangements

• Working Depth Extensions

Contact Factory or Dealer for priceadjustment.

Booth dimensions and price aresubject to change without notice.

NOTE:

This design can be used for hotmetal spraying. When heavyoverspraying is anticipated, a pumpwater wash booth may be the bestchoice. This design often producesexhaust air that is moisture laden.

Typical Vapor-tight Fluorescent LightingArrangement. 4-tube. Under 10’ W.D.

Page 50: BLEEKER DIGITAL CATALOG

BLE

EK

ER

Toll Free 800.421.1107 49

PUMPLESS WATER-WASH BOOTHS

• 16-Gauge Galvanized Steel Washer Panels

• 12-Gauge Galvanized Steel Tank

• Bolt Construction. Inside of Booth in smooth.

• Light Windows contain 1/4" Clear Tempered Glass

• The Wash Chamber extends the full width of the Booth.

• The Washers are engineered to work efficiently between 3" to 5" of static pressure.

• A vaneaxial exhaust blower of spark-resistant construction is utilized. Blower is belt driven with

AC

B

CONSTRUCTION FEATURES

bearings and motor separated from the air stream allowing the blower to be used to exhaust hazardous paint fumes and vapors.

• Working Depth 18-Gauge Galvanized Steel

• Spray Booth Working Depth Panels rest on heavy duty 14-Gauge Galvanized floor Angles.

• Face Velocity exceeds code requirement of 100 F. P. M.

• Face Velocity and Static Pressure will change due to Job Site Duct Requirements (Offsets, Duct Length) etc.

MODEL NO. WIDTH HEIGHT WORKING LIGHTS WIDTH DEPTH *EXHAUST MOTOR C. F. M. DUCT AVERAGE SHIPPING I. D. I.D. DEPTH I. D. NO. & TYPE OVERALL OVERALL BLOWER H. P. @ 4 1/2” S.P DIA. FACE WEIGHT (A) (B) (C) DIA. VELOCITY VELOCITY LBS.

PLW-4-7-5 4'-0" 6'-10" 5'-0" 1-VT-FLUR 4'-4" 9'-2" 1-15” 1-5 3,500 24 125 2,000

PLW-4-7-7 4-0" 6'-10" 7'-0" 1-VT-FLUR 4'-4" 11'-2" 1-15” 1-5 3,500 24 125 2,080

PLW-4-8-5 4'-0" 7'-10" 5'-0" 1-VT-FLUR 4'-4" 9'-2" 1-15” 1-5 4,000 24 125 2,020

PLW-4-8-7 4'-0" 7'-10" 7'-0" 1-VT-FLUR 4'-4" 11'-2" 1-15” 1-5 4,000 24 125 2,100

PLW-5-7-5 5'-0" 6'-10" 5'-0" 1-VT-FLUR 5'-4" 9'-2" 1-18” 1-7-1/2 4,375 24 125 2,200

PLW-5-7-7 5'-0" 6'-10" 7'-0" 1-VT-FLUR 5'-4" 11'-2" 1-18” 1-7-1/2 4,375 24 125 2,280

PLW-5-8-5 5'-0" 7'-10" 5'-0" 1-VT-FLUR 5'-4" 9'-2" 1-18” 1-7-1/2 5,000 24 125 2,220

PLW-5-8-7 5'-0" 7'-10" 7'-0" 1-VT-FLUR 5'-4" 11'-2" 1-18” 1-7-1/2 5,000 24 125 2,300

PLW-6-7-5 6'-0" 6'-10" 5'-0" 1-VT-FLUR 6'-4" 9'-2" 1-18” 1-7-1/2 5,250 24 125 2,500

PLW-6-7-7 6'-0" 6'-10" 7'-0" 1-VT-FLUR 6'-4" 11'-2" 1-18” 1-7-1/2 5,250 24 125 2,580

PLW-6-8-5 6'-0" 7'-10" 5'-0" 1-VT-FLUR 6'-4" 9'-2" 1-21” 1-7-1/2 6,000 24 125 2,520

PLW-6-8-7 6'-0" 7'-10" 7'-0" 1-VT-FLUR 6'-4" 11'-2" 1-21” 1-7-1/2 6,000 24 125 2,600

PLW-8-7-5 8'-0" 6'-10" 5'-0" 2-VT-FLUR 8'-4" 9'-2" 1-21” 1-10 7,000 30 125 3,000

PLW-8-7-7 8'-0" 6'-10" 7'-0" 2-VT-FLUR 8'-4" 11'-2" 1-21” 1-10 7,000 30 125 3,100

PLW-8-8-5 8'-0" 7'-10" 5'-0" 2-VT-FLUR 8'-4" 9'-2" 1-21” 1-10 8,000 30 125 3,050

PLW-8-8-7 8'-0" 7'-10" 7'-0" 2-VT-FLUR 8'-4" 11'-2" 1-21” 1-10 8,000 30 125 3,150

PLW-8-10-5 8'-0" 9'-10" 5'-0" 3-VT-FLUR 8'-4" 9'-2" 1-21” 1-15 9,700 30 125 3,280

PLW-8-10-7 8'-0" 9'-10" 7'-0" 3-VT-FLUR 8'-4" 11'-2" 1-21” 1-15 9,700 30 125 3,400

PLW-10-7-7 10'-0" 6'-10" 7'-0" 2-VT-FLUR 10'-4" 11'-2" 1-21” 1-15 8,750 30 125 3,600

PLW-10-7-10 10'-0" 6'-10" 10'-0" 2-OT-FLUR 10'-4" 14'-2" 1-21” 1-15 8,750 30 125 3,750

PLW-10-8-7 10'-0" 7'-10" 7'-0" 3-VT-FLUR 10'-4" 11'-2" 1-24” 1-15 10,000 34 125 3,900

PLW-10-8-10 10'-0" 7'-10" 10'-0" 3-OT-FLUR 10'-4" 14'-2" 1-24” 1-15 10,000 34 125 3,960

PLW-10-10-7 10'-0" 9'-10" 7'-0" 3-VT-FLUR 10'-4" 11'-2" 1-24” 1-15 12,000 34 120 4,020

PLW-10-10-10 10'-0" 9'-10" 10'-0" 3-OT-FLUR 10'-4" 14'-2" 1-24” 1-15 12,000 34 120 4,200

PLW-10-12-7 10'-0" 11'-10" 7'-0" 3-VT-FLUR 10'-4" 11'-2" 1-28” 1-20 15,000 42 125 4,480

PLW-10-12-10 10'-0" 11'-10" 10'-0" 3-OT-FLUR 10'-4" 14'-2" 1-28” 1-20 15,000 42 125 4,680

* Vaneaxial Exhaust Blower. ©1999 BLEEKER BROS.

Page 51: BLEEKER DIGITAL CATALOG

BLE

EK

ER

50 EMAIL: [email protected] www.BleekerBros.com

PUMPLESS WATER-WASH BOOTHS

PLW-12-7-7 12'-0" 6'-10" 7'-0" 3-VT-FLUR 12'-4" 11'-2" 1-24” 1-15 10,500 34 125 4,550

PLW-12-7-10 12'-0" 6'-10" 10'-0" 3-OT-FLUR 12'-4" 14'-2" 1-24” 1-15 10,500 34 125 4,710

PLW-12-8-7 12'-0" 7'-10" 7'-0" 3-VT-FLUR 12'-4" 11'-2" 1-24” 1-15 12,000 34 125 4,750

PLW-12-8-10 12'-0" 7'-10" 10'-0" 3-OT-FLUR 12'-4" 14'-2" 1-24” 1-15 12,000 34 125 4,950

PLW-12-10-7 12'-0" 9'-10" 7'-0" 3-VT-FLUR 12'-4" 11'-2" 1-28” 1-20 15,000 42 125 4,990

PLW-12-10-10 12'-0" 9'-10" 10'-0" 3-OT-FLUR 12'-4" 14'-2" 1-28” 1-20 15,000 42 125 5,150

PLW-12-12-7 12'-0" 11'-10" 7'-0" 3-VT-FLUR 12'-4" 11'-2" 1-28” 1-25 18,000 42 125 5,040

PLW-12-12-10 12'-0" 11'-10" 10'-0" 3-OT-FLUR 12'-4" 14'-2" 1-28” 1-25 18,000 42 125 5,366

PLW-14-7-7 14'-0" 6'-10" 7'-0" 3-VT-FLUR 15'-0" 11'-2" 1-24” 1-15 12,250 34 125 5,100

PLW-14-7-10 14'-0" 6'-10" 10'-0" 3-OT-FLUR 15'-0" 14'-2" 1-24” 1-15 12,250 34 125 5,270

PLW-14-8-7 14'-0" 7'-10" 7'-0" 4-VT-FLUR 15'-0" 11'-2" 1-28” 1-20 14,000 42 125 5,300

PLW-14-8-10 14'-0" 7'-10" 10'-0" 4-OT-FLUR 15'-0" 14'-2" 1-28” 1-20 14,000 42 125 5,350

PLW-14-10-7 14'-0" 9'-10" 7'-0" 4-VT-FLUR 15'-0" 11'-2" 1-32" 1-20 17,500 42 125 5,200

PLW-14-10-10 14'-0" 9'-10" 10'-0" 4-OT-FLUR 15'-0" 14'-2" 1-32" 1-20 17,500 42 125 5,390

PLW-14-12-7 14'-0" 11'-10" 7'-0" 4-VT-FLUR 15'-0" 11'-2" 2-24" 2-15 21,000 30 125 5,250

PLW-14-12-10 14'-0" 11'-10" 10'-0" 4-OT-FLUR 15'-0" 14'-2" 2-24" 2-15 21,000 30 125 5,480

PLW-16-7-7 16'-0" 6'-10" 7'-0" 4-VT-FLUR 17'-0" 11'-2" 1-28" 1-20 14,000 42 125 5,500

PLW-16-7-10 16'-0" 6'-10" 10'-0" 4-OT-FLUR 17'-0" 14'-2" 1-28" 1-20 14,000 42 125 5,680

PLW-16-8-7 16'-0" 7'-10" 7'-0" 4-VT-FLUR 17'-0" 11'-2" 1-28" 1-25 16,000 42 125 5,550

PLW-16-8-10 16'-0" 7'-10" 10'-0" 4-OT-FLUR 17'-0" 14'-2" 1-28" 1-25 16,000 42 125 5,720

PLW-16-10-7 16'-0" 9'-10" 7'-0" 4-VT-FLUR 17'-0" 11'-2" 2-24" 2-15 20,200 34 125 5,590

PLW-16-10-10 16'-0" 9'-10" 10'-0" 4-OT-FLUR 17'-0" 14'-2" 2-24" 2-15 20,200 34 125 5,800

PLW-16-12-7 16'-0" 11'-10" 7'-0" 5-VT-FLUR 17'-0" 11'-2" 2-24" 2-20 24,000 34 125 5,650

PLW-16-12-10 16'-0" 11'-10" 10'-0" 5-OT-FLUR 17'-0" 14'-2" 2-24" 2-20 24,000 34 125 5,880

PLW-18-7-7 18'-0" 6'-10" 7'-0" 4-VT-FLUR 19'-0" 11'-2" 1-28" 1-20 15,750 42 125 6,700

PLW-18-7-10 18'-0" 6'-10" 10'-0" 4-OT-FLUR 19'-0" 14'-2" 1-28" 1-20 15,750 42 125 6,900

PLW-18-8-7 18'-0" 7'-10" 7'-0" 4-VT-FLUR 19'-0" 11'-2" 1-28" 1-20 18,000 42 125 6,750

PLW-18-8-10 18'-0" 7'-10" 10'-0" 4-OT-FLUR 19'-0" 14'-2" 1-28" 1-20 18,000 42 125 6,950

PLW-18-10-7 18'-0" 9'-10" 7'-0" 4-VT-FLUR 19'-0" 11'-2" 2-24" 2-15 22,500 34 125 6,800

PLW-18-10-10 18'-0" 9'-10" 10'-0" 4-OT-FLUR 19'-0" 14'-2" 2-24" 2-15 22,500 34 125 7,020

PLW-18-12-7 18'-0" 11'-10" 7'-0" 5-VT-FLUR 19'-0" 11'-2" 2-28" 2-15 26,800 42 125 7,400

PLW-18-12-10 18'-0" 11'-10" 10'-0" 5-OT-FLUR 19'-0" 14'-2" 2-28" 2-15 26,800 42 125 7,500

PLW-20-7-10 20'-0" 6'-10" 10'-0" 6-OT-FLUR 21'-0" 14'-2" 1-32" 1-20 17,500 42 125 7,300

PLW-20-7-12 20'-0" 6'-10" 12'-0' 6-OT-FLUR 21'-0" 16'-2" 1-32" 1-20 17,500 42 125 7,440

PLW-20-8-10 20'-0" 7'-10" 10'-0" 5-OT-FLUR 21'-0" 14'-2" 2-24” 2-15 20,000 42 125 7,480

PLW-20-8-12 20'-0" 7'-10" 12'-0' 6-OT-FLUR 21'-0" 16'-2" 2-24” 2-15 20,000 42 125 7,660

PLW-20-10-10 20'-0" 9'-10" 10'-0" 6-OT-FLUR 21'-0" 14'-2" 2-24" 2-15 25,000 42 125 7,450

PLW-20-10-12 20'-0" 9'-10" 12'-0' 6-OT-FLUR 21'-0" 16'-2" 2-24" 2-15 25,000 42 125 7,610

PLW-20-12-10 20'-0" 11'-10" 10'-0" 6-OT-FLUR 21'-0" 14'-2" 2-28” 2-20 30,000 42 125 7,700

PLW-20-12-12 20'-0" 11'-10" 12'-0' 6-OT-FLUR 21'-0" 16'-2" 2-28" 2-20 30,000 42 125 7,960

* Vaneaxial Exhaust Blower.

MODEL NO. WIDTH HEIGHT WORKING LIGHTS WIDTH DEPTH *EXHAUST MOTOR C. F. M. DUCT AVERAGE SHIPPING I. D. I.D. DEPTH I. D. NO. & TYPE OVERALL OVERALL BLOWER H. P. @ 4 1/2” S.P DIA. FACE WEIGHT (A) (B) (C) DIA. VELOCITY VELOCITY LBS.

A C

B

©1999 BLEEKER BROS.

Page 52: BLEEKER DIGITAL CATALOG

BLE

EK

ER

Toll Free 800.421.1107 51

SLUDGE REMOVAL CENTRIFUGE

Additional Benefits with thisequipment:

• Reduces disposal costs

• Recycles booth water

• Works with virtually all chemical treatment programs

• Extremely low maintenance

• No filters or consumables

• Very few moving parts

• Durable construction

• Low utility requirements

• Simple to operate

These systems are highly technical.Contact a knowledgeable Dealer orBLEEKER BROS. EngineeringDepartment.

CONSIDER THEFOLLOWINGINFORMATION:

• Total number and volume of booths

• Current maintenance program

• Chemical supplier and costs

• Estimated annual disposal costs

• Percent solids of paint in use

• Approximate transfer efficiency

• Paint use in gallons per day

Sludge Removal Systemsdimensions and prices subject tochange without notice.

Sludge RemovalSystemsCentrifugal Equipment does the job!

Centrifugal cleansing equipment canbe designed to fit your particularneeds, from a single water washbooth to several. Various stages offiltration of the paint pigments, fromsolid waste to hardened brick style,depending on local conditions andcodes to facilitate disposal.

BLEEKER BROS. water wash spraybooths are designed to accept or beretrofitted with Sludge RemovalSystems and should be consideredwhen the following conditions exist:

• Frequent maintenance down time

• Extra working shifts

• High cost of liquid sludge removal and disposal

GENERAL INFORMATION

Page 53: BLEEKER DIGITAL CATALOG

PAINT MIX ROOMSB

LEEK

ER

52 EMAIL: [email protected] www.BleekerBros.com

Compliance with OSHA andLocal Fire and SafetyRegulationBleeker’s Mixing Rooms are designedto comply with OSHA and localfire/safety regulation for proper useand ventilation To contain anypossible spills, mixing rooms must beinstalled on a minimum 4 inch highmounting curb. Be sure to check withyour contractor and local authoritiesregarding codes. Study allinstructions carefully and observe allsafety precautions during operation.Subject to Fire Dept. approvalpending quanity of paint storedand/or mixed.

Optional Equipment• Windows: 16” wide x 54” high

frames with clear tempered glassare available on wall panels. Pleasespecify number of window panelsdesired when ordering.

• Explosion proof fan and lightswitches.

• Electric Safety Interlock System,which will automatically shut off thefan while the door remains open.Fan will start when door is closed.

• 4” high x 4” wide galvanized steel curb including approach ramps.

Contact Factory or Dealer for priceadjustment.

Specifications Mix Rooms - All Models

Intake Filters• Intake filter, Type AIF• 20”x 20” with built in

reinforcement frames.

Intake and Exhaust and Motor • Motor is out of room. • Non-sparking blade tubeaxial fan.• Exhaust is balanced to provide

best air flow.• Design minimizes solvent laden

air from entering shop or shop air entering mix room.

Booth Construction• 18 gauge galvanized steel • Prepunched holes on 6”centers • Easy nut and bolt assembly.

Miscellaneous• All necessary hardware and and

caulking is included to assembly booth.

Side Access Door includes:• 36” X 80” with 24”x 36”

observation window• Brixon latch P-2.

• Door handles

Lighting• Fluorescent light fixture(s),

UL and C-UL approved • Designed for mounting outside

the booth.• Set in framed clear tempered

glass openings. • Dust tight seals on windows and

doors.

NOTES:Fire code limitation 150’ sq ft. floorarea. Air Supply optional.

PMR-9-8-6 9’ 4”wide 8’ high 6’ 4” long

PMR-9-8-8 9’ 4” wide 8’ high 8’ 4” long

PMR-9-8-10 9’ 4” wide 8’ high 10’ 4” long

PMR-9-8-12 9’ 4” wide 8’ high 12’ 4” long

Inside dimensions:Outside dimensions:

PMR-9-8-6 9’ wide 7’ 10” high 6’ long

PMR-9-8-8 9’ wide 7’ 10” high 8’ long

PMR-9-8-10 9’ wide 7’ 10” high 10’ long

PMR-9-8-12 9’ wide 7’ 10” high 12’ long

DIMENSIONS

Mix RoomBleeker’s Paint Mixing Rooms areconstructed of 18 gauge rigidlyreinforced companion flangedgalvanized panels and are ready forbolting to each other. Each mix roomhas a personnel access doormeasuring 3’ wide x 6’8” high whichmay be located on either side of themix room.

Light SystemGood lighting is most necessary withall mix rooms: therefore Bleekerincorporates even light distributionwith a 4 tube light fixture. 120 volts ULand C-UL approved vapor tight isincluded.

Air VentilationTo remove vapors, a ventilatingsystem creates a continuous flow offresh air through the room.

Automatic Damper ClosureFire Damper System, required by FireDept. codes, include a heat sensitivefusible link that melts in fire andcloses the damper.

Four Spacious Room SizesTough, free standing and totally self-contained mixing rooms are built toprovide years of service. Ceiling are 8ft high. Solid 18 gauge galvanizedsteel wall panels.

C

B

A

PART NO. A B C PART NO. A B C

Page 54: BLEEKER DIGITAL CATALOG

BLE

EK

ER

Toll Free 800.421.1107 53

FINAL FILTER FRAMES

F-2-18 2 18” 4,000 250

F-4-24 4 24” 8,000 400

F-4-30 4 30” 8,000 475

F-6-30 6 30” 12,000 525

F-6-34 6 34” 12,000 575

F-6-36 6 36” 12,000 625

F-8-34 8 34” 16,000 650

F-8-36 8 36” 16,000 700

F-8-42 8 42” 16,000 735

F-10-42 10 42” 20,000 800

F-12-42 12 42” 24,000 925

# FILTER FAN PART NO. CELLS DIAMETER CFM WT

Construction Features

• 18 ga. Galvanized steel

• Bolt construction. Inside is smooth.

• Filter cells are 24” x 24” x 12”, constructed from heavy duty 14 ga. galvanized material.

Features

• Maximum Capacity of each Final Filter is 2,000 CFM.

• For motor selection, see Powder Containment Booths, pg. 15, anddetermine booth size.

• Fan diameter must be stated at time of order.

• Standard filter arrangements as shown.

• Other configerations available. Contact Factory or Dealer for pricing.

• Manometer, pressure switch and 95% Final Filters sold separately.

• If 99.9% Hepa Filters are required, contact factory for details and pricing.

NOTES

Dimension and price are subject tochange without notice.

Final Filter Frames are used toconvert wet (spraying liquid) to dry(using powder) applications. Theunits may be added to an existingfilter booth to convert it to a powdercontainment booth. Powdercontainment booth must remainindoors.

Final Filters (FIN-F-24-24) should beused in conjunction with powder Pre-filters and Pocket filters installed inthe booth in order to protect andextend the life of the final filters. Thefan and motor selection should besuch to allow for ample airflow at thetotal pressure drop (dirty condition)through all filters installed in thebooth.

All Final Filters adhere to theUniform Fire Code and the NationalElectrical Code.

Always check local fire andelectrical codes for specialconditions that may apply.

GENERAL INFORMATION

F - 2 F - 4 F - 6

F - 8 F - 10 F - 12

©1999 BLEEKER BROS.

Page 55: BLEEKER DIGITAL CATALOG

BOOTH DOORS

PD-36-84 30" 6'-8" 3'-0" 7'-0" 12” X 12” 140

PD-42-84 36" 6'-8" 3'-6" 7'-0" 18” X 18” 180

BLE

EK

ER

54 EMAIL: [email protected] www.BleekerBros.com

AL-FD-9 9'-0" 8'-6" 10'-0" 9'0" 16 412

VL-FD-9 9'-0" 9'-6" 10'-0" 10'0" 20 419

ATL-FD-10 10'-0" 11'-6" 11'-0" 12'0" 24 620

TL-FD-11 11'-0" 14'-0" 12'-0" 14'6" 42 711

FILTER LEAF DOORS

AF-FD-9 9'-0" 8'-6" 10'-0" 9'0" 16 450

VF-FD-9 9'-0" 9'-6" 10'-0" 10'0" 20 475

ATF-FD-10 10'-0" 11'-6" 11'-0" 12'0" 24 700

TF-FD-11 11'-0" 14'-0" 12'-0" 14'6" 32 800

FILTER BI-FOLDING DOORS

AF-SD-9 9'-0" 8'-6" 10'-0" 9'-0" 18” X 18” 650

VF-SD-9 9'-0" 9'-6" 10'-0" 10'-0" 18” X 18” 675

ATF-SD-10 10'-0" 10'-6" 11'-0" 11'-0" 18” X 18” 1100

TF-SD-11 11'-0" 13'-6" 12'-0" 14'-0" 18” X 18” 1275

SOLID BI-FOLDING DOORS

PERSONNEL DOORS

DOOR PACKAGEINCLUDES:

Jambs and header

All necessary hardware forappropriate door

Rubber gasket material

Complete set of 20”x20” intakefilters included with filter doors

NOT INCLUDED:

Door interlocks

MODEL DOOR DOOR DOOR DOOR WINDOW SHIPPINGWIDTH HEIGHT ASSEMBLY ASSEMBLY SIZE WEIGHT

WIDTH HEIGHT LBS.

• Door 18 gauge steel

• Jambs 12 gauge steel (personnel door 14 gauge)

• Filter cells 20” X 20” X 3”

• Solid doors may be replaced with roll-up, electrical or manually operated doors. Contact Factory for specifications.

MODEL DOOR DOOR DOOR DOOR FILTERS SHIPPINGWIDTH HEIGHT ASSEMBLY ASSEMBLY WEIGHT

WIDTH HEIGHT LBS.

MODEL DOOR DOOR DOOR DOOR FILTERS SHIPPINGWIDTH HEIGHT ASSEMBLY ASSEMBLY WEIGHT

WIDTH HEIGHT LBS.

MODEL DOOR DOOR DOOR DOOR WINDOW SHIPPINGWIDTH HEIGHT ASSEMBLY ASSEMBLY SIZE WEIGHT

WIDTH HEIGHT LBS.

CONSTRUCTION FEATURES

AL-SD-9 9'-0" 7'-8" 10'-0" 8”0” 18” X 18” 612

VL-SD-9 9'-0" 8'-8" 10'-0" 9’0” 18” X 18” 619

ATL-SD-10 10'-0" 10'-6" 11'-0" 12’0” 18” X 18” 1000

TL-SD-11 11'-0" 13'-6" 12'-0" 14’0” 18” X 18” 1263

SOLID LEAF DOORSMODEL DOOR DOOR DOOR DOOR WINDOW SHIPPING

WIDTH HEIGHT ASSEMBLY ASSEMBLY SIZE WEIGHTWIDTH HEIGHT LBS.

©1999 BLEEKER BROS.

Page 56: BLEEKER DIGITAL CATALOG

BOOTH COMPONENTS

BLE

EK

ER

Toll Free 800.421.1107 55

54" P2-6-54 10 P2-12-54 15 P2-18-54 20 P2-24-54 25 P2-30-54 30 P2-36-54 35 P2-42-54 40

60" P2-6-60 10 P2-12-60 15 P2-18-60 20 P2-24-60 25 P2-30-60 30 P2-36-60 35 P2-42-60 40

84" P2-6-84 14 P2-12-84 21 P2-18-84 28 P2-24-84 35 P2-30-84 42 P2-36-84 49 P2-42-84 56

96" P2-6-96 14 P2-12-96 24 P2-18-96 24 P2-24-96 40 P2-30-96 48 P2-36-96 48 P2-42-96 64

120" P2-6-120 20 P2-12-120 30 P2-18-120 34 P2-24-120 50 P2-30-120 60 P2-36-120 70 P2-42-120 80

144" P2-6-144 24 P2-12-144 36 P2-18-144 48 P2-24-144 60 P2-30-144 72 P2-36-144 84 P2-42-144 96

Standard P2 Panels

Standard P4 Boxed Panels

6" WIDE 12" WIDE 18" WIDE 24" WIDE 30" WIDE 36" WIDE 42" WIDETYPICAL LENGTH PART NO. WT. PART NO. WT. PART NO. WT. PART NO. WT. PART NO. WT. PART NO. WT. PART NO. WT.

24" P4-6-24 4 P4-12-24 6 P4-18-24 8 P4-24-24 10 ------- ----- ------- ------- ------- ------

30" P4-6-30 5 P4-12-30 7.5 P4-18-30 10 P4-24-30 12.5 P4-30-30 15 ------- ------- ------- -----

36" P4-6-36 6 P4-12-36 9 P4-18-36 12 P4-24-36 15 P4-30-36 18 P4-36-36 21 ------- ------

42" P4-6-42 7 P4-12-42 10.5 P4-18-42 14 P4-24-42 17.5 P4-30-42 21 P4-36-42 24.5 P4-42-42 28

48" P4-6-48 8 P4-12-48 12 P4-18-48 16 P4-24-48 20 P4-30-48 24 P4-36-48 28 P4-42-48 32

54" P4-6-54 9 P4-12-54 13.5 P4-18-54 18 P4-24-54 22.5 P4-30-54 27 P4-36-54 31.5 P4-42-54 36

60" P4-6-60 10 P4-12-60 15 P4-18-60 20 P4-24-60 25 P4-30-60 30 P4-36-60 35 P4-24-60 40

72" P4-6-72 12 P4-12-72 18 P4-18-72 24 P4-24-72 30 P4-30-72 36 P4-36-72 42 P4-42-72 48

84" P4-6-84 14 P4-12-84 21 P4-18-84 28 P4-24-84 35 P4-30-84 42 P4-36-84 49 P4-42-84 56

96" P4-6-96 16 P4-12-96 24 P4-18-96 32 P4-24-96 40 P4-30-96 48 P4-36-96 56 P4-42-96 64

120" P4-6-120 20 P4-12-120 30 P4-18-120 40 P4-24-120 50 P4-30-120 60 P4-36-120 70 P4-42-120 80

144" P4-6-144 24 P4-12-144 36 P4-18-144 48 P4-24-144 60 P4-30-144 72 P4-36-144 84 P4-42-144 96

6" WIDE 12" WIDE 18" WIDE 24" WIDE 30" WIDE 36" WIDE 42" WIDETYPICAL LENGTH PART NO. WT. PART NO. WT. PART NO. WT. PART NO. WT. PART NO. WT. PART NO. WT. PART NO. WT.

©1999 BLEEKER BROS.

©1999 BLEEKER BROS.

Page 57: BLEEKER DIGITAL CATALOG

FC-42 3'-6" 18 GA. 7

FC-48 4'-0" 18 GA. 8

FC-60 5'-0" 18 GA. 10

FC-72 6'-0" 18 GA. 12

FC-96 8'-0" 14 GA. 33

FC-120 10'-0" 14 GA. 42

FC-144 12’-0” 14 GA. 50

FC-168 14'-0" 12 GA. 90

FC-192 16'-0" 12 GA. 100

FC-216 18'-0" 12 GA. 115

FC-240 20'-0" 12 GA. 130

FC-264 22'-0" 12 GA. 143

FC-288 24'-0" 12 GA. 160

FC-312 26'-0" 7 GA. 350

FC-336 28'-0" 7 GA. 370

FC-360 30'-0" 7 GA. 400

PART NO. LENGTH GAUGE WT.

BOOTH COMPONENTSB

LEEK

ER

56 EMAIL: [email protected] www.BleekerBros.com

FIRE CURTAINS

CB-14 14'-0" 12 GA. 125

CB-16 16'-0" 12 GA. 145

CB-18 18'-0" 12 GA. 160

CB-20 20'-0" 12 GA. 180

CB-22 22'-0" 12 GA. 195

CB-24 24'-0" 12 GA. 215

CB-26 26'-0" 7 GA. 460

CB-28 28'-0" 7 GA. 500

CB-30 30'-0" 7 GA. 530

CENTER BEAMS

CU-90 7'-6" 12 GA. 35

CU-102 8'-6" 12 GA. 40

CU-126 10'-6" 12 GA. 50

CU-150 12'-6" 12 GA. 60

CENTER UPRIGHTSBOOTHS 4' TO 24' WIDE

AU-106 8'-10" 12 GA. 40

AU-116 9'-8" 12 GA. 44

ATU-142 11'-10" 12 GA. 50

TU-190 15'-10" 12 GA. 65

AUTOMOTIVEUPRIGHTS

ATB-116 9'-8" 12 GA. 22

VTB-116 9'-8" 12 GA. 22

ATTB--128 10'-8" 12 GA. 25

TTB-140 11'-8" 12 GA. 27

AUTOMOTIVETOP BEAMS

FBS-120 10'-0" 12 GA. 6.6

FBS-144 12'-0" 12 GA. 8.0

FLAT BAR STIFFENERS

FU-6-90 7'-6" 12 GA. 24

FU-6-102 8'-6" 12 GA. 28

FU-6-126 10'-6" 12 GA. 35

FU-6-150 12'-6" 12 GA. 40

PART NO. LENGTH GAUGE WT.

FRONT UPRIGHTSFront Upright

Front Upright

Fire Curtain26’ to 30’

Fire Curtain12’ Wide and Under

Fire Curtain14’ to 24’

PART NO. LENGTH GAUGE WT.

PART NO. LENGTH GAUGE WT.

PART NO. LENGTH GAUGE WT.

PART NO. LENGTH GAUGE WT. PART NO. LENGTH GAUGE WT.

©1999 BLEEKER BROS.

2”2”

2”

6”

2”

4”

Page 58: BLEEKER DIGITAL CATALOG

BOOTH COMPONENTS

2”

CC-84 84" 7

CC-96 96" 8

CC-120 120" 10

CC-144 144" 12

CORNER CHANNELS

PFS-120 10'-0" 14 GA. 10

PFS-144 12'-0" 14 GA. 12

PANEL FLANGESUPPORTS

FA-6 6" 0.6

FA-12 12" 1.2

FA-18 18" 1.8

FA-24 24" 2.4

FA-30 30" 3.0

FA-36 36" 3.6

FA-42 42" 4.2

FA-48 48" 4.8

FA-54 54" 5.4

FA-60 60" 6.0

FA-72 72" 7.2

FA-84 84" 8.4

FA-96 96" 9.6

FA-120 120" 12.0

FA-144 144" 14.4

FLOOR ANGLES - 14 GA

TA-6 6" 0.6

TA-12 12" 1.0

TA-18 18" 2.0

TA-24 24" 2.5

TA-30 30" 3.5

TA-36 36" 4.0

TA-42 42" 4.5

TA-48 48" 5.0

TA-54 54" 5.5

TA-60 60" 6.0

TA-72 72" 7.0

TA-84 84" 8.0

TA-96 96" 9.6

TA-120 120" 12.0

TA-144 144" 14.4

TIE-IN ANGLES - 14 GA.*PART NO. LENGTH WT.

* NOTE: Also used as Filter Bank Roof Supports

2”

2”

BLE

EK

ER

Toll Free 800.421.1107 57

PART NO. LENGTH GAUGE WT.

PART NO. LENGTH WT.

NUMBER LENGTH WT.

1 3/4”

1 3/4”

2”

2”

©1999 BLEEKER BROS.

Page 59: BLEEKER DIGITAL CATALOG

BOOTH COMPONENTSB

LEEK

ER

58 EMAIL: [email protected] www.BleekerBros.com

GP-12 34"X12" 12

GP-18 34"X18" 18

GP-24 34"X24" 22

GP-30 34"X30" 24

GP-36 34"X36" 30

GP-42 34"X42" 36

GP-48 34"X48" 40

GP-60 34"X60" 45

BLANK GABLE PANELSPART NO. SIZE WT.

FP4-24-42-18 24 42 18 23.5

FP4-24-48-18 24 48 18 26.0

FP4-30-36-24 30 36 24 29.0

FP4-36-36-24 36 36 24 36.0

FP4-36-36-30 36 36 30 40.0

FP4-36-42-30 36 42 30 43.5

FP4-36-48-30 36 48 30 47.0

FP4-42-48-34 42 48 34 54.0

FP4-42-48-36 42 48 36 55.0

FP4-48-48-42 48 48 42 67.0

FP4-54-60-48 54 60 48 81.0

STANDARD BOX FANPANELwith fan angle rings

PART NO. WIDTH LENGTH FAN SIZE WT.

GWP-60 34"X60" 35

GABLE PANELS with 16" X 54" window

PART NO. SIZE WT.

©1999 BLEEKER BROS.

Page 60: BLEEKER DIGITAL CATALOG

BOOTH COMPONENTS

BLE

EK

ER

Toll Free 800.421.1107 59

48" BWI-30-48-1 30 BWI-36-48-1 34

60" BWI-30-60-1 36 BWI-36-60-1 44

72" BWI-30-72-1 42 BWI-36-72-1 48

96" BWI-30-96-2 52 BWI-36-96-2 60

120" BWI-30-120-2 64 BWI-36-120-2 74

144" BWI-30-144-3 76 BWI-36-144-3 88

PANEL 30” WIDE 36’ WIDELENGTH PART NO. WT. PART NO. WT.

BOX WINDOW PANELS with 24" X 24" windowfor Incandescent Lights

BOX WINDOW PANELSwith 16” X 54” windowfor Fluorescent Lights

60" WI-30-60 41 WI-36-60 42 WI-42-60 59

84" WI-30-84 57 WI-36-84 50 WI-42-84 84

96" WI-30-96 65 WI-36-96 80 WI-42-96 96

PANEL 30” WIDE 36’ WIDE 42” WIDELENGTH PART NO. WT. PART NO. WT. PART NO. WT.

60" WF-24-60 27 WF-30-60 33 WF-36-60 39 WF-42-60 45

72” WF-24-72 32 WF-30-72 42 WF-36-72 50 WF-42-72 58

84" WF-24-84 41 WF-30-84 54 WF-36-84 63 WF-42-84 71

96" WF-24-96 48 WF-30-96 64 WF-36-96 80 WF-42-96 84

120” WF-24-120 66 WF-30-120 83 WF-36-120 100 WF-42-120 118

144” WF-24-144 80 WF-30-144 103 WF-36-144 123 WF-42-144 143

60" BWF-30-60-1 38 BWF-36-60-1 42

72" BWF-30-72-1 45 BWF-36-72-1 50

96" BWF-30-96-1 56 BWF-36-96-1 64

120" BWF-30-120-2 62 BWF-36-120-2 72

144" BWF-30-144-2 74 BWF-36-144-2 86

PANEL 30” WIDE 36’ WIDELENGTH PART NO. WT. PART NO. WT.

PANEL 24” WIDE 30’ WIDE 36” WIDE 42” WIDELENGTH PART NO. WT. PART NO. WT. PART NO. WT. PART NO. WT.

WINDOW PANELSwith 24” X 24” windowfor Incandescent Lights

WINDOW PANELSwith 16” X 54” windowfor Fluorescent Lights

3’0” MINIMUM

3’0” MINIMUM

©1999 BLEEKER BROS.

2”

2”

2”

1/2”

2”

1/2”

Page 61: BLEEKER DIGITAL CATALOG

BLE

EK

ER

60 EMAIL: [email protected] www.BleekerBros.com

BOOTH ACCESSORIES

Industrial Vapor-Tight FluorescentLight Fixture (LH-500)

• Accepts energy saving T-8 tubes• Requires 4 tubes (not included).• U.L. and C-U.L. approved• Meets National Electric Code,

Class 1, Division 2 for hazardous areas.

• No restrictions for fixture placement on exterior of booth.

• 4’ long.• 120 V. (Other voltages available.)

Industrial Open-Type FluorescentLight Fixture (LO-500)

Industrial Vapor-TightIncandescent Light Fixture (IV-300)

• Accepts energy saving T-8 tubes.

• Requires 4 tubes (not included).• U.L. and C-U.L. approved.• Must be placed not less than

three feet from front of booth or any opening in booth.

• Must be placed behind 1/4” tempered glass.

• 4’ long.• 120 V. (Other voltages available.)

• No restrictions for fixture placement on exterior of booth.

• 300 watt ( Bulb not included).• Meets National Electric Code,

Class 1, Division 2 for hazardous areas.

• Must be placed behind 1/4” tempered glass.

Explosion Proof IncandescentLight Fixtures (IEX-300)

Turn Table w/Legs (T-T)

• 1/2” Dia. Standard Size• Required on all paint spray

booths.• Prevents operation of spray gun

unless exhaust fan is in operation.

• Comes single phase 110, 220, or440 volts. (When ordering specify voltage.)

• Explosion proof solenoid valve and larger diameters available. Contact factory for pricing.

• Differential pressure gauge required for filtered spray booths.

• Aids in determining need for filter replacement.

• Dll-O (oil dye) included.

• Meets Class1, Division 2• Required equipment on most

spray booth doors.• When door is opened, prevents

paint spray operation.

Solenoid Valve (SV0-2)

• Used to sense dirty filter conditions in powder containment booths.

• Use PS-2 to sense airflow and pressure on dry filter booths.

• Can be used at front or inside of booth.

• Meets National Electric Code Class 1, Division 1 for hazardous areas.

• Explosion Proof Angle Fixture often mounted on front of booth with short working depths.

• Overhead mounted lighting used in extra hazardous conditions.

Door Interlock with Bracket andRoller (VTI-A)(Limit Switch)

Manometer (DII)

Pressure Switch (PS-1)

Page 62: BLEEKER DIGITAL CATALOG

BLE

EK

ER

Toll Free 800.421.1107 61

BOOTH ACCESSORIES

* WFU-54 Window Frame PartsBolted To Existing Panel.

WFU-54

Glass Hold-Downs18” Long

Window Frame Parts Boltedto Existing Panel

WFU-24

HSP-16-54

HEP-16-54

FLC-60

• For Weather Protection

Includes:• Frame• Glass holddowns• Gasketing

Glass not included.

GLASSCTG-12-12 1/4 “ Clear tempered Glass11 1/2” x 11 1/2” Wt. 5 Ibs.

CTG-15-53 1/4” Clear tempered Glass15” x 53” Wt. 20 Ib.

CTG-18-18 1/4” Clear tempered Glass17 1/2” x 17 1/2” Wt. 8 lbs.

CTG-24-24 1/4” Clear tempered Glass 23 1/2” x 23 1/2” Wt. 14 Ib.

GLASS HOLD-DOWNS (ONE PAIR)

GHD-18 18” Long Wt. 2.5 Ibs.

GHD-48 48” Long Wt. 6.8 Ibs.

• Hinged window frame for Open-Type fixture only. (LO-500)

• Fixture remains stationary.

• Hinged panel for Vapor-Tight fixture only. (LH-500)

• Fixture swings in with panel.

Includes:• Frame• Glass holddowns• Gasketing

Glass not included.

Window FrameUnit Complete

Fluorescent Light Cover

Window Frame Unit Complete

Bolt Window Frame To Existing Panel

Bolt Window Frame To Existing Panel.

Page 63: BLEEKER DIGITAL CATALOG

EXHAUST DUCT COMPONENTSB

LEEK

ER

62 EMAIL: [email protected] www.BleekerBros.com

NOTES

Duct is designed to meet specifications ofUniform Fire Code.

All duct material is galvanized. Gauge isindicated with diameter.

Prices and specifications are subject to changewithout notice.

45° Elbow (E45)

90° Elbow (E90)Snow Shield for Canopy withDamper

• Connects fan to duct

• Used at end of 90° elbows.• Hardware cloth on exhaust

end and is tapered back to protect from rain

• Not recommended for areas with snow fall.

• To be used in snow and high wind areas.

Canopy—Weather (WC)

• Used for roof mounted fan installation.

Canopy—Vertical Exhaust withAutomatic Damper (CP)

Canopy—All Weather (AWC)

• Use two 45° elbows• For specifications

refer to page 71.

• For specifications refer to page 71.

Duct Angle Ring (DAR)

Eyebrow with Screen (E-45)

Fan Stand (SF)

Page 64: BLEEKER DIGITAL CATALOG

BLE

EK

ER

Toll Free 800.421.1107 63

EXHAUST DUCT COMPONENTS

Roof Flange Cover (RFC)

• Standard 3’ long

• Recommended use with Weather or All Weather canopy.

• Standard 3’ long• Used to inspect fan/blade/duct

conditions.• Door size 18” x 18” door.

• Refer to illustration of exhaust duct assembly page 72.

Roof Flange—Pitched—Custom(RFP)

Insulated Sleeve (IS)

AD -Access Door (door in Door Joint)

Collar (C)

Fan Adaptor (FA)

Plain Joint (PJ)

Door Joint with AutomaticDamper (DJD)

Door Joint (DJ)

Roof Flange—Flat (RFF)Guy Wires (GW-3)

• Protects fan motor on outside installation.

• Used on 36” fan to reduce duct size to a more conventional 34” size.

• 1” fiberglass, 4’ long, glued to 22 gauge galvanized steel

• Used to close roof flange opening when duct is removed.

• Refer to illustration of exhaust duct assembly, page 72.

Motor Enclosure (ME-A)

• Sheds rain over the roof flange.

Page 65: BLEEKER DIGITAL CATALOG

VELOCITY CONE AND MUFFLERSB

LEEK

ER

64 EMAIL: [email protected] www.BleekerBros.com

Velocity Cone (VC) forCanopy w/damper

Velocity Cone-Open foropen end duct (VCO)

MLR-12 12" 53

MLR-18 18" 53

MLR-24 24" 53

MLR-30 30" 55

MLR-34 34" 55

MLR-42 42" 67

MLR-48 48" 67

Standard Muffler(MLR)

• Used to reduce noise.• Contact dealer or Bleeker Bros.

for individual recommendations.

MLR-HE-12 12" 53

MLR-HE-18 18" 53

MLR-HE-24 24" 53

MLR-HE-30 30" 55

MLR-HE-34 34" 55

MLR-HE-42 42" 67

MLR-HE-48 48" 67

High Efficiency Muffler(MLR-HE)

MODEL DECIBEL REDUCERNO. DIA. “A”

12" 8”

18" 13”

24" 19”

30" 25”

34" 29”

42" 37”

48" 43”

VELOCITY CONE DATADIAMETER

“A” “B”

Typical Muffler

Velocity Cones aredesigned to increase thedischarge velocity to atleast 3600 FPM to complywith environmental codes.

VELOCITY CONES

MODEL DECIBEL REDUCERNO. DIA. “A”

©1999 BLEEKER BROS.

Page 66: BLEEKER DIGITAL CATALOG

ELECTRIC MOTORS

BLE

EK

ER

Toll Free 800.421.1107 65

TE0050-1 1/2 1725 56 5/8 28

TE0075-1 3/4 1725 56 5/8 35

TE0100-1 1 1725 143T 5/8 42

TE0150-1 1-1/2 1725 145T 7/8 47

TE0200-1 2 1740 182T 7/8 65

TE0300-1 3 1740 184T 1-1/8 86

TE0500-1 5 1730 213T 1-1/8 113

EXP-0050-3 1/2 1725 56 5/8 39

EXP-0075-3 3/4 1725 56 5/8 41

EXP-0100-3 1 1725 56H 5/8 47

EXP-0150-3 1-1/2 1725 56H 5/8 46

EXP-0200-3 2 1740 145T 7/8 68

EXP-0300-3 3 1740 182T 1-1/8 94

EXP-0500-3 5 1740 184T 1-1/8 118

EXP-0750-3 7-1/2 1740 213T 1-3/8 171

EXP-1000-3 10 1740 215T 1-3/8 188

TE0030-3 1/3 1725 56 5/8 18

TE0050-3 1/2 1725 56 5/8 23

TE0075-3 3/4 1725 56 5/8 25

TE0100-3 1 1755 143T 7/8 49

TE0150-3 1-1/2 1745 145T 7/8 50

TE0200-3 2 1740 145T 7/8 55

TE0300-3 3 1735 182T 1-1/8 99

TE0500-3 5 1740 184T 1-1/8 101

TE0750-3 7-1/2 1745 213T 1-3/8 160

TE1000-3 10 1750 215T 1-3/8 195

TE1500-3 15 1745 254T 1-5/8 305

TE2000-3 20 1745 256T 1-5/8 345

THREE PHASE TOTALLY ENCLOSED, FAN COOLED

MODEL NO. H. P. R. P. M. FRAME* SHAFT DIA.* WEIGHT

EXP-0030-1 1/3 1725 56 5/8 34

EXP-0050-1 1/2 1725 56 5/8 36

EXP-0075-1 3/4 1725 56 5/8 42

EXP-0100-1 1 1725 56H 5/8 47

*Availability may alter frame, shaft size and weight.

SINGLE PHASE TOTALLY ENCLOSED, FAN COOLED MOTORS

MODEL NO. H. P. R. P. M. FRAME* SHAFT DIA.* WEIGHT

MODEL NO. H. P. R. P. M. FRAME* SHAFT DIA.* WEIGHT

THREE PHASE EXPLOSION PROOF MOTORS with conduit box for hazardous location

MODEL NO. H. P. R. P. M. FRAME* SHAFT DIA.* WEIGHT

SINGLE PHASE EXPLOSION PROOF MOTORSwith conduit box for hazardous location

*Availability may alter frame, shaft size and weight.

*Availability may alter frame, shaft size and weight.

*Availability may alter frame, shaft size and weight.

©1999 BLEEKER BROS.

Page 67: BLEEKER DIGITAL CATALOG

BOOTH FILTERSB

LEEK

ER

66 EMAIL: [email protected] www.BleekerBros.com

Galvanized Wire Mesh Filter(BG-20-20)

Roll Media (BB-32-66)

Pre-Filter (PRE-F-20-20)

Pocket Filter (POC-F-20-20)

Final Filter ( FIN-F-24-24)

High Efficiency Filter (BB-33-32)

• This type of paint arrestor is most widely used throughout the United States and Canada.

• 20”x20”• 20”x25”• Two filters required per cell.• Meets NFPA Standard No. 33 &

U.S. U.L. Approved Class 2.

• Popular with grinding booths.• 20” x 20” x 2”• One filter required per cell.

Paint Arrestor (BB-30-32)

Fiberglass Paint Arrestors (BB-20-20)

• 1st stage filter for powder containment inside booth filter wall

EXHAUST FILTERS FOR WETMATERIAL

EXHAUST FILTERS FOR DRYMATERIAL

• Order with Roll Converter (GGA) and Connector (GGC-20)

EXHAUST FILTERS FORVARSOL MATERIAL

• Used with Varsol booths ONLY.

• 2nd stage filter for powder containment inside booth filter wall

• 3rd stage filter for powder containment.

• To be used with Final Filter Box• 95% efficiency

Page 68: BLEEKER DIGITAL CATALOG

BOOTH FILTERS

BLE

EK

ER

Toll Free 800.421.1107 67

Hi Volume Filter (DP-40-20-20)

• Standard air intake filter used on totally enclosed spray booths to achieve a dust free atmosphere.

• 20” x 20”• 20” x 25”• One filter required per cell.

• One rod and one grid used for each exhaust cell.

• Grid is 20” x 20” or 20” x 25”

• Rod is 20” long

FF-20-20-3 20” 20” 3” 4.5FF-20-25-3 20” 25” 3” 5.0

Filter Banks areassembled byplacing one frameagainst another,inserting bolts orrivets in accuratelypunched holes.

PART NO. LENGTH WIDTH DEPTH Wt.

Air Intake Filter (AIF 20-20)

Air Intake Filter (A-300)

• Higher efficiency air intake filter used on down-draft booths.

• 20” x 20” x 1”• 20” x 25” x 1”• One filter required per cell.

Gripper Grid (GG-20-20) and Rod (GG-R-20)

Standard Filter Frames(all 18 gauge)

Roll Media Connector (GGC-20)

AIR-INTAKE FILTERS

Roll Media Grid (GGA-20-20)

FILTER ACCESSORIES

• 20”x20”x2”• Pleated• 40% efficiency

• Used to connect roll media to filter bank at top.

• 20” long.

• Used to hold roll media in frame

• Grid is 20” X 20” or 20” X 25”.

©1999 BLEEKER BROS.

Page 69: BLEEKER DIGITAL CATALOG

TUBEAXIAL EXHAUST FANB

LEEK

ER

68 EMAIL: [email protected] www.BleekerBros.com

TUBEAXIAL EXHAUST FAN

• 12" to 48" Diameter Spark-Resistant

• Fabricated Aluminum Blades

• AMCA certified ratings for air and sound

Our Tubeaxial Exhaust Fans are designed and built forheavy duty use in exhausting paint spray booths, cleaningtanks, mixing rooms and similar specialized applications,as well as being widely used for industrial ventilation ofhazardous fumes and vapors at temperatures up to 200degrees F.

The precision balanced six-winged, spark-resistantfabricated aluminum fan blades provide air deliveries upto 1-1/2" SP. All models have permanently pre-lubricatedoversized ball bearings: bearings in the 12" through 36"fans are rubber insulated in a die-formed housing; 42"and 48" fans have pillow block construction. ExhaustFans can be mounted in any position for convenience ininstallation. Cast iron drive pulley is assembled on thefan, 24" through 48" models have a malleable split-taperbushing fan pulley. Motor drive and bearings are

TEF-12 12" 5/8" 14-7/16 12 12-1/4 5/16 13-1/2 8-3/4 33

TEF-18 18" 7/8" 21-1/8 16-1/2 18-1/2 5/16 19-7/8 12-1/2 53

TEF-24 24" 1" 27 18 24-5/16 7/16 25-3/4 16-3/16 88

TEF-30 30" 1-3/16" 33-5/8 24 30-1/2 7/16 32-1/4 19-1/4 195

TEF-34 34" 1-3/16" 37-3/4 29 34-1/2 7/16 36-1/4 21-3/8 235

TEF-36 36" 1-3/16" 39-3/4 29 36-1/2 7/16 38-1/4 22-7/16 245

TEF-42 42" 1-7/16" 45-3/4 32 42-1/2 9/16 44-1/4 25-3/16 371

TEF-48 48" 1-7/16" 51-3/4 36 48-1/2 9/16 50-1/4 28-5/16 461

insulated from the air stream to allow hazardous air andvapor to be exhausted without causing damage to the driveor motor. Housing is cleaned, bonderized and finished withZinc Chromate Primer and coated with an alkaloid bakedenamel for lasting protection.

TUBEAXIAL EXHAUST FAN DIMENSIONS (Dimensions in inches )

MODEL BLADE SHAFT SHIPPING NO. DIAMETER DIAMETER WEIGHT

(A) (B) (C) (D) (E) (F) LBS.

©1999 BLEEKER BROS.

Page 70: BLEEKER DIGITAL CATALOG

BLE

EK

ER

Toll Free 800.421.1107 69

TUBEAXIAL EXHAUST FAN

TEF-18 18"

SHIPPING WEIGHT53 LBS.

1/3 2090 1600 1515 1400 1270 ---- ---- ---- ---- ---- ---- ---- ---- ---- 82

1/2 2253 1915 1610 1515 1400 1210 ---- ---- ---- ---- ---- ---- ---- ---- 84

3/4 2877 2435 2380 2315 2250 2175 2090 1955 ---- ---- ---- ---- ---- ---- 86

1/3 1375 3165 2910 2640 2300 ---- ---- ---- ---- ---- ---- ---- ---- ---- 80

1/2 1487 3495 3270 3010 2720 2280 1125 ---- ---- ---- ---- ---- ---- ---- 82

3/4 1719 4040 3845 3635 3400 3120 2810 1710 1200 ---- ---- ---- ---- ---- 84

1 1988 4660 4485 4290 4100 3900 3665 3385 3050 1950 ---- ---- ---- ---- 86

1-1/2 2255 5300 5170 5040 4930 4790 4665 4500 4050 3800 ---- ---- ---- ---- 88

1 1312 7085 6695 6260 5800 5250 ---- ---- ---- ---- ---- ---- ---- ---- 83

1-1/2 1466 7945 7575 7200 6780 6300 5760 4960 4500 2800 ---- ---- ---- ---- 86

2 1688 9140 8820 8500 8185 7800 7400 6950 6800 6490 5800 4100 ---- ---- 88

3 1910 10290 10090 9860 9620 9380 9140 8870 8400 8155 7900 7445 7000 6000 90

1-1/2 1030 10955 10415 9815 9250 8395 ---- ---- ---- ---- ---- ---- ---- ---- 84

2 1146 12190 11710 11180 10750 9990 9250 8485 6200 ---- ---- ---- ---- ---- 86

3 1320 14040 13630 13180 12750 12220 11700 11105 10450 9740 7900 ---- ---- ---- 87

5 1551 16495 16150 15785 15200 14995 14250 14145 13750 13190 12900 12125 11200 10250 89

2 936 14430 13760 13020 12200 11285 10250 7155 ---- ---- ---- ---- ---- ---- 84

3 1074 16560 15985 15350 14800 13965 13100 12305 11200 7750 ---- ---- ---- ---- 86

5 1251 19290 18800 18280 17800 17150 16800 15880 15100 14445 13750 12180 8200 6400 88

2 837 15255 14455 13570 12600 11430 9800 ---- ---- ---- ---- ---- ---- ---- 84

3 964 17570 16890 16135 15300 14450 13250 12345 9100 ---- ---- ---- ---- ---- 88

5 1133 20650 20080 19460 18900 18135 17500 16605 15800 14825 13400 9400 6900 6400 89

3 746 21465 20430 19275 17950 16585 13800 9000 ---- ---- ---- ---- ---- ---- 86

5 880 25320 24460 23505 22400 21435 20100 18965 17500 12400 ---- ---- ---- ---- 87

7-1/2 1013 29150 28410 27610 26500 25900 24950 23960 22900 21775 20200 18120 12250 ---- 89

10 1147 33005 32355 31670 31000 30185 29250 28620 27700 26850 26000 24920 ---- ---- 92

5 731 31250 30070 28745 27150 25810 23900 22170 ---- ---- ---- ---- ---- ---- 88

7-1/2 827 35365 34325 33185 31875 30750 29200 27900 25200 24390 19300 ---- ---- ---- 89

10 891 38100 37140 36105 34900 33885 32450 31380 29500 28550 27000 24060 17400 ---- 92

BLADEDIAMETER

H. P. BLADE FREE .125 0.25 .375 0.5 0.625 0.75 0.875 1.0 1.125 1.25 1.375 1.5 AVE.R.P.M. AIR DBA RATING

C. F. M. AT STATIC PRESSURE SHOWN

MODELNO.

TEF-12 12"

SHIPPING WEIGHT33 LBS.

TEF-24 24"

SHIPPING WEIGHT88 LBS.

TEF-30 30"

SHIPPING WEIGHT195 LBS.

TEF-34 34"

SHIPPING WEIGHT235 LBS.

TEF-36 36"

SHIPPING WEIGHT245 LBS.

TEF-42 42"

SHIPPING WEIGHT371 LBS.

TEF-48 48"

SHIPPING WEIGHT461 LBS.

©1999 BLEEKER BROS.

Page 71: BLEEKER DIGITAL CATALOG

BLE

EK

ER

70 EMAIL: [email protected] www.BleekerBros.com

MISCELLANEOUS BOOTH HARDWARE

SCREWSTS-10-3-4 (100 box — TEK screw) .75 Ib.

#10 x 3/4” self tapping TEK screws.

Recommended for assembly ofexhaust duct.

TS-14-1 (100 box — TEK screw) 1.75 Ib.

#14 x 3/4” self tapping TEK screws.

Recommended to attach door hingesto jambs.

SEALANTSSC-11

1.0 Ib.

Silicone caulking—11 oz. tube usedfor sealing water wash unit

LC-11 (caulking) 1.25 Ib.

Latex caulking — 11 oz. tube usedfor sealing automotive booth panels.

CG (dispenser) 1.0 Ib.

Caulking gun

FILTER HARDWAREGG-20-20 (grid) 4.0 Ib.

20” x 20” grid — one used for each exhaust filter cell.

GG-20-25 (grid) 4.5 Ib.

20” x 25” grid — one used for eachexhaust filter cell

GG-R-20 (rod) 2 oz.

20” long rod — one used per grid

GASKETSET-3100-16 (per foot — gasket material) 3 oz.

1/4” x 1/2” used to seal glass inspray booth

RG-32-4 (50’ roll — gasket material) 6 oz.

5/32” x 3/4” rubber gasket materialused to seal doors

FN-16 (6” x 120” rubber) 2.25 Ib.

1/16” flat neoprene rubber used toseal center of booth doors

FN-8(3” x 120” rubber) 2.25 Ib.

1/8” flat neoprene rubber used toseal bottom of booth doors

LATCHESBL-P-2 (latch) 2.0 Ib.

Small Brixon safety latch & striker

BL-P-3(latch) 3.75 Ib.

Large Brixon safety latch & striker

NUTS AND BOLTSTHN-16-4 (500 box—nuts) 6.0 Ib.

Nuts for 5/16” x 3/4”truss-head bolts

THB-16-4 (500 box—bolts)12.0 Ib.

5/16”x3/4” bolts

Page 72: BLEEKER DIGITAL CATALOG

BLE

EK

ER

Toll Free 800.421.1107 71

ELBOW AND OFFSET DUCT SPECIFICATIONS

90 ° ELBOW (2 45 ° Elbows)

STANDARD OFFSET (2 45° Elbows Opposed)

SHORT OFFSET (Assembled Upon Request)

TYPICAL DUCT CONNECTIONS

12" 12"

18" 21"

24" 27"

30" 31"

34" 36"

42" 42"

48" 42"

12" 8" 18"

18" 12" 30"

24" 17" 38"

30" 18" 45 1/2

34" 22" 53"

42" 24" 61"

48" 24" 62"

12" 22

18" 22

24" 20

30" 20

34" 18

42" 18

48" 18

12" 2" 11"

18" 3 1/2" 17 1/2"

24" 4 3/4" 25"

30" 4 3/4" 24 1/4"

34" 6" 30"

42" 7 1/2" 32"

48" 6 1/4" 32 1/2"

NOTE:

Conforms to Uniform Fire Coderequirements.

DUCT X Y

DUCT X Y

STACK DIA. GA. STEEL

DUCT X

©1999 BLEEKER BROS.

Page 73: BLEEKER DIGITAL CATALOG

BLE

EK

ER

72 EMAIL: [email protected] www.BleekerBros.com

EXHAUST STACK FOR PAINT SPRAY BOOTHS

STACK GAUGE OF ROOF OPENINGDIAMETER STEEL (MINIMUM)

12" 22 18”

18" 22 24”

24" 20 30”

30" 20 36”

34" 18 40”

42" 18 48”

48" 18 54”

• Attach duct work together with self-tapping screws. Use #10 x 3/4" long sheet metal screws.Space screws approximately 12" around the circumference of the stack.

• Refer to Uniform Fire Code.• All electrical and plumbing to conform to local

codes.• Insulated duct must run 18" above and below any

combustible material.

©1999 BLEEKER BROS.

Page 74: BLEEKER DIGITAL CATALOG

BLE

EK

ER

Toll Free 800.421.1107 73

ELECTRICAL CODES

1. Cross section of open type fluorescent light with 16" x 54" x 1/4" clear tempered glass. Light is always on the outside of booth. Portable Lamp may not be used inside of booths.

2. Cross section of vapor tight incandescent light with 24" x 24" x 1/4" clear tempered glass. Light is always on the outside of booth. Portable lamps may not be used.

3. Electrical fixtures (switches, electrical boxes, etc.) within 3'-0" area from front of booth must comply with the National Electric Code for Class I, Division 2 locations. Drawing shows two different options in lighting arrangements.

NOTE: The vapor tight lights may beplaced anywhere behind 1/4" cleartempered glass.

4. When booth has front doors with adoor switch (interlock), open type fluorescent lights must be a minimum of 3'-0" from the door opening. When door is open interlock is activated closing solenoid valve shutting air off to spray equipment. Front doors must have air intake filter cells.

NOTE: Interlock system preventspaint gun from being used when fanis not in operation.

5. Class I Division I & 2 Areas-Where booth does not have an air interlock system (see NOTES for item 6).

6. Class I Division 2 Areas - When booth has an air interlock system (see NOTES below).

NOTE: Class 1 Division 1 - Inside ofbooth where vapors and residuesmay be present in quantitiessufficient to produce explosive andignitible mixtures under normaloperating conditions.

NOTE: Class 1, Division 2 - Areaoutside of booth. 5 & 6 shows paintspray booth and hazardous area around the booth. All electrical inthis area shall comply with Article501 of the National Electrical Code.

12

3

4

5

6

1/4” CLEAR TEMPERED GLASS

TYPICAL INCANDESCENTVAPOR-TIGHT LIGHT

LIGHT BRACKET

GLASS HOLD-DOWN

GASKET MATERIAL

EXHAUST FAN

FAN MOTOR

TO 3 PHASEPOWERSOURCE

TO SINGLEPHASE POWERSOURCE

3’ 0” MIN

INCANDESCENT VAPOR-TIGHTLIGHTS MAY BE PLACEDANYWHERE BEHIND 1/4”CLEAR TEMPERED GLASS.

AIRFLOW

SOLENOIDVALVE

AIR COMPRESSOR

LINE

OPEN-TYPE FLUORESCENT LIGHT

DOORSWITCH

HAZARDOUSAREA CLASS 1DIVISION 2WITHOUT AIRINTERLOCKSYSTEM

HAZARDOUS AREACLASS 1 DIVISION 1(INSIDE BOOTH)

HAZARDOUS AREACLASS 1, DIVISION 2USING AN AIRINTERLOCK SYSTEM

HAZARDOUS AREACLASS 1, DIVISION 1(INSIDE BOOTH)

5’ 0”

10’ 0”3’ 0”

3’ 0”

3’ 0”

5’ 0”

3’ 0”MINIMUM

AIRCOMPRESSORLINE

OPEN TYPE FLUORESCENTLIGHT

©1999 BLEEKER BROS.

Page 75: BLEEKER DIGITAL CATALOG

BLE

EK

ER

74 EMAIL: [email protected] www.BleekerBros.com

INDEX

Airflow switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60Air intake filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67Air Make-up Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40Air supply-typical arrangements . . . . . . . . . . . . . . . . . . . . . . . .42All Weather Canopy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62Automotive Top Beams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56Automotive Uprights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56Bench Filter boot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10Blank Gable Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58Bleeker-Cure Infrared Package . . . . . . . . . . . . . . . . . . . . . . . . .38-39Bolts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70Booth Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60-61

Glass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61Glass hold-downs . . . . . . . . . . . . . . . . . . . . . . . . . . . .61Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60

Cover for Fluorescent Light . . . . . . . . . . . . . . . .61Fluorescent Open-type . . . . . . . . . . . . . . . . . . .60Fluorescent Vapor-tight . . . . . . . . . . . . . . . . . . .60Hinged Panel Cover for LO-500 . . . . . . . . . . . .61Hinged Window Frame for LH-500 . . . . . . . . . .61Incandescent Explosion Proof . . . . . . . . . . . . . .60Incandescent Vapor-tight . . . . . . . . . . . . . . . . . .60

Limit Switch/Door Interlock . . . . . . . . . . . . . . . . . . . . .60Manometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60Pressure Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60Solenoid Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60Turn Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60Window Frame Unit . . . . . . . . . . . . . . . . . . . . . . . . . .61

Booth components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55-59Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60Automotive Top Beams . . . . . . . . . . . . . . . . . . . . . . . .56Automotive Uprights . . . . . . . . . . . . . . . . . . . . . . . . . .56Blank Gable Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . .58Box Fan Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58Box Window Panels . . . . . . . . . . . . . . . . . . . . . . . . . .59Center Beams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56Center Uprights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56Corner Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57Fire Curtains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56Flat Bar Stiffeners . . . . . . . . . . . . . . . . . . . . . . . . . . . .56Floor Angles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57Front Uprights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56Gable Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58P-2 Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55P-4 Box Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55Panel Flange Supports . . . . . . . . . . . . . . . . . . . . . . . .57Tie-in Angles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57Window Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59

Booth stylesWindow Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59Air Make-up Units . . . . . . . . . . . . . . . . . . . . . . . . . . . .40Bench Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10Cartridge-Batch Type . . . . . . . . . . . . . . . . . . . . . . . . .18Cartridge-Production Type . . . . . . . . . . . . . . . . . . . . .18Crossdraft Style Booths . . . . . . . . . . . . . . . . . . . . . . .20, 24

Cover for Fluorescent Light . . . . . . . . . . . . . . . .61Auto Crossdraft Filter . . . . . . . . . . . . . . . . . . . . .22Auto-truck Crossdraft Filter . . . . . . . . . . . . . . . .26Truck Crossdraft Filter . . . . . . . . . . . . . . . . . . . .27Van Crossdraft Filter . . . . . . . . . . . . . . . . . . . . .23

Downdraft Grinding Enclosures . . . . . . . . . . . . . . . . .43Downdraft Style Booths . . . . . . . . . . . . . . . . . . . . . . .28

Auto Downdraft . . . . . . . . . . . . . . . . . . . . . . . . .29Auto-truck Downdraft . . . . . . . . . . . . . . . . . . . .29Truck Downdraft . . . . . . . . . . . . . . . . . . . . . . . .29Van Downdraft . . . . . . . . . . . . . . . . . . . . . . . . . .29

Exhaust Plenums . . . . . . . . . . . . . . . . . . . . . . . . . . . .32Dual (Automotive type) . . . . . . . . . . . . . . . . . . . .33Industrial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33Powder Containment . . . . . . . . . . . . . . . . . . . . .34

Flash-off Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . .36Floor Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6Infared Bleeker-Cure Booths . . . . . . . . . . . . . . . . . . . .38Paint Mix Rooms . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52

Powder Containment . . . . . . . . . . . . . . . . . . . . . . . . .14Powder Containment Bench . . . . . . . . . . . . . . . . . . . .16Recirculating Heat Systems . . . . . . . . . . . . . . . . . . . .35Semi-Downdraft Style Booths . . . . . . . . . . . . . . . . . . .30

Auto Semi-Downdraft . . . . . . . . . . . . . . . . . . . .31Auto-truck Semi-Downdraft . . . . . . . . . . . . . . . .31Truck Semi-downdraft . . . . . . . . . . . . . . . . . . . .31Van Semi-Downdraft . . . . . . . . . . . . . . . . . . . . .31

Sludge Removal Systems . . . . . . . . . . . . . . . . . . . . . .51Special Application Bench Filter . . . . . . . . . . . . . . . . .11Varsol Bench . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12Water Wash Booths

Bench . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46Pumpless . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48

Box Fan Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58Box Window Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59Brixon latches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70Canopy with damper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62Cartridge-Batch type booth . . . . . . . . . . . . . . . . . . . . . . . . . . .18Cartridge-Production type booth . . . . . . . . . . . . . . . . . . . . . . .18Caulking supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70Center beams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56Center uprights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56Choosing your Booth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 5

Booth size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Cross flow air movement . . . . . . . . . . . . . . . . . . . . . . 5Downdraft air movement . . . . . . . . . . . . . . . . . . . . . . . 5Filter booths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Flash-off drying enclosures . . . . . . . . . . . . . . . . . . . . . 5Heated air make-up . . . . . . . . . . . . . . . . . . . . . . . . . . 5Semi-downdraft booths . . . . . . . . . . . . . . . . . . . . . . . 5True downdraft booths . . . . . . . . . . . . . . . . . . . . . . . . 5Water wash booths . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Collar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Components, booth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55-59Components, duct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62-63Containment booths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14-17Corner channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57Crossdraft style booths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20-24Decibel reducer (muffler) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64Door joint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Door joint with automatic damper . . . . . . . . . . . . . . . . . . . . . .63Doors, booth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54

Filter Bi-folding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54Filter Leaf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54Personnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54Solid Bi-folding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54Solid Leaf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54

Door interlock switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60Downdraft Grinding Enclosures . . . . . . . . . . . . . . . . . . . . . . . .43Downdraft style booths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28-29Duct angle ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62Duct components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62-63

45° Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6290° Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62All Weather Canopy . . . . . . . . . . . . . . . . . . . . . . . . . .62Canopy with damper . . . . . . . . . . . . . . . . . . . . . . . . . .62Collar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Door joint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Door joint with automatic damper . . . . . . . . . . . . . . .63Duct angle ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62Eyebrow with screen . . . . . . . . . . . . . . . . . . . . . . . . . .62Fan adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Fan stand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62Guy wire kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Insulated sleeve . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Motor enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Plain joint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Roof flange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Roof flange cover . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Snow Shield for Canopy . . . . . . . . . . . . . . . . . . . . . . .62Weather Canopy . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62

Page 76: BLEEKER DIGITAL CATALOG

INDEX

BLE

EK

ER

Toll Free 800.421.1107 75

Elbows-45° . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62Elbows-90° . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62Electric motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65Electrical Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73Exhaust duct components . . . . . . . . . . . . . . . . . . . . . . . . . . . .62-63Exhaust fan, tubeaxial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68Exhaust Plenums . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32Explosion proof light fixtures . . . . . . . . . . . . . . . . . . . . . . . . . .60Explosion proof motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65Eyebrow with screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68-69Fan adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Fan stand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62Fiberglass paint arrestors . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66-67

Air intake filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67Fiberglass paint arrestors . . . . . . . . . . . . . . . . . . . . . .66Final filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66High efficiency filters . . . . . . . . . . . . . . . . . . . . . . . . . .66Hi-volume filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67Paint arrestors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66Pocket filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66Pre-filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66Roll media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66Varsol filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66

Filter Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67Gripper Grid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67Gripper Rod . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67Roll media Connector . . . . . . . . . . . . . . . . . . . . . . . . .67Roll media Grid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67

Filter Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67Final filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66Final Filter Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53Fire Curtains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56Flash-off Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36Flat Bar Stiffeners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56Floor Angles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57Floor Filter booths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Front Uprights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56Gable Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58Gasket material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70Glass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61Glass hold-downs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61Gripper Grid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67Gripper Rod . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67Guy wire kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70

Bolts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70Nuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70Screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70Tek-screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70

High efficiency filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66Hi-volume filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67Infared Bleeker-Cure Booth Packages . . . . . . . . . . . . . . . . . . .38Interlock switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60Insulated sleeve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60

Cover for Fluorescent Light . . . . . . . . . . . . . . . . . . . . .61Fluorescent Open-type . . . . . . . . . . . . . . . . . . . . . . . .60Fluorescent Vapor-tight . . . . . . . . . . . . . . . . . . . . . . . .60Hinged Panel Cover for Fluor. Open-type . . . . . . . . . .61Hinged Window Frame for Fluor. Vapor-tight . . . . . . .61Incandescent Explosion Proof . . . . . . . . . . . . . . . . . .60Incandescent Vapor-tight . . . . . . . . . . . . . . . . . . . . . .60

Limit Switch/Door Interlock . . . . . . . . . . . . . . . . . . . . . . . . . . .60Manometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65

Explosion proof, single phase . . . . . . . . . . . . . . . . . . .65Explosion proof, three phase . . . . . . . . . . . . . . . . . . . .65Totally enclosed, single phase . . . . . . . . . . . . . . . . . . .65Totally enclosed, three phase . . . . . . . . . . . . . . . . . . .65

Motor enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Mufflers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64

High-efficiency muffler . . . . . . . . . . . . . . . . . . . . . . . .64Standard muffler . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64

Noise reduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Nuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69P-2 Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55P-4 Box Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55Paint arrestors filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66Paint Mix Rooms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52Panel Flange Supports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57Plain joint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Pocket filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66Powder Containment booths . . . . . . . . . . . . . . . . . . . . . . . . . .14Powder Containment Bench booths . . . . . . . . . . . . . . . . . . . .16Pre-filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66Pressure Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60Recirculating Heat Systems . . . . . . . . . . . . . . . . . . . . . . . . . . .35Roll media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66Roll media Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67Roll media Grid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67Roof flange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Roof flange cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63Screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71Selecting your Painting Equipment . . . . . . . . . . . . . . . . . . . . . 2-3Semi-Downdraft Style booths . . . . . . . . . . . . . . . . . . . . . . . . .30Sludge Removal Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51Snow Shield for Canopy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62Solenoid Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60Special Application Bench Filter booths . . . . . . . . . . . . . . . . . .11Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71-72

Elbow and Offset Duct . . . . . . . . . . . . . . . . . . . . . . . .71Exhaust stack for Spray Booths . . . . . . . . . . . . . . . . .72

Tek-screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70Things to consider - ordering your Booth . . . . . . . . . . . . . . . . . 3-4Tie-in Angles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57Tubeaxial exhaust fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68-69Types of Booths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Typical Air Supply arrangements . . . . . . . . . . . . . . . . . . . . . . .42Varsol Bench booths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12Varsol filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66Velocity cones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64Water Wash booths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44-48Window Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59