bright septic tank
DESCRIPTION
betonski saht nacrtTRANSCRIPT
150 StandardTee Pipe outlet
Pre cast ConcreteAccess Cover
225 Brick Wall
1:2:4 Conc.
B r c No 8 or Equivalent
150 StandardTee Pipe inlet
B r c No 8 or Equivalent
1:2:4 ConcreteBase Slab
Grease Seat
1:2:4 ConcreteBenching
1:3 CementMortar 12mm Thick
50mm Pre cast Cover
Grease Seat
10mm M S BarsBent to Shape
25 Cover
Concrete Footing
150mmØ pipe outlet
Open Joint Block WallHoney Combed
Packed With BrickBats Concrete Pieces
or 150 Rubble
50 Pre cast Concrete Access Cover
ConcreteFooting 1:2:5
Invert or Soak awayNot to be Concrete
Open Jointed CementBlock Wall
Honey Combed
Block Wall Rendered1:5 Cement Mortar on
Inside
2 No12mm Ø Bar@ 75 ctrs.
225x150 R.CBeam 225 x 150mm
AREAS
floor
ceilinginternalwall
MATERIAL SPECIFICATIONSbenchingconcrete
foundation concreteto septic tank
hardcore filling
450
3000
soil and vent pipe
above roof levelballoon cage to svp termination
flushing cistern
cistern overflow pipe
floor fin.
wc with 50mmminimum seal 50mm dia. anti- syphonage pipe
inspection eye
1500
12.All inside surfaces of aseptic tank shall be madesmooth with mortar mix C
SCALE (1:25)
DETAIL OF PRE CAST R.C. ACCESS COVER
8 No 6mm Ø bars @ 225 ctrs,
PLAN
1150
11.The floor of a septic tankshall be of concrete mix Dat least 150mm thick andslope to a gradient of not lessthan one in twentydownwards towards the inletpipe.
L.I 139 10.The walls of aseptic tank shall be ofconcrete,plain or reinforcedof at least 150mm thick orconcrete mix C or of burntbrick work of at least 150mmthick set in mortar mix D
20751375
900
600
350
350
350
A
3000225225
350
1375 Cover
Access
1200
1550
2257350
SECTION A - A
1200
C
C
D
D
150 Standard SewageGas Interception Dilution
The War brick or Equivalent
225
1025
125
350 1375
225X225mm R.C Beam
4 No12mmØ Bar
Top water level
50mm Pre cast Concrete Access Cover
4700
350
3450
125
100mm R.C Slab10
25
50 Blinding
525
350
4700
DETAIL OF EFFLUENT MANHOLESECTION D - D
Bitumen Seat
450
200
150
50 SCALE (1:25)
SCALE (1:25)
600 150
100
700600
- PLAN -50
5055
045
0
SECTION F - F
600
200
50 50
B r c No 8 or Equivalent17535
015
5052
510
2535
047
00
3450
50
Top water level accumulated gases are expectedto be expelled througt vent atleast 600m above eaves withopen end protected againstnesting birds
6.The dimensions of onecompartment of a septic tankshall be such that the totallength is at least four timesthe width and where the tankis divided into twocompartments,the length ofthe first compartment shall bemore than half of the totallength of the septic tank.
LEACHING CHAMBERLENGTH
1.05m
1.35m1.43m
1.58m
225
Cover
Access
1550
2251500
350
225
2252
25
350
Cover
Access 350600600 1550
2400
3300
2252
25
A
USER CAPACITYNO OF PERSONS
DIGSTIONS CHAMBERLENGTH WIDTH
10-14
15-20
21-25
26-30
31-35
36-40
2.1m
2.4m
2.7m2.85m
3.0m
3.15m
1.05m
1.2m
1.2m1.35m
1.5m
1.58m
1.2m
1.5m
STANDARD DIMENSIONS FOR SEPTIC TANK
WIDTH
1.4m
1.05m
1.2m
1.35m
1.5m
1.58m
septic tank must be at least30 meters from any waterbody which be used fordomestic purposes and atsufficient height not to allowfor any pollution through thesoil to such a body.
drain should be givingsufficient fall(eg. in 40 for100mm pipe)joints should be properlymade to prevent blocking ofthe aperture
septic tank must beconstructed in concrete withthe top at least 150m aboveground leveloverall depth of septic tankbelow ground level isdetermined by the inlet andshall not be less than 1800mthe depth below inlet levelshall also be 1400-1500mmand any case nnot less than1200mmbaffle screen must beprovided to prevent directflow belween inlet and outletseptic tank should be openevery six months and depthof top crust ascertained ifthis exceed 30cm surplusshould be removed andburied
SCHEMATIC SECTION
p.v.c main pipe toseptic tank
1:4:8 50mm Blinding
Bitumen Seat
1375
inspection chamber
50mm main waste waterpipe to soak pit
100mm Ø
BASIN
SINKBATH
URINAL
VIII
VI
VII
V
IV
VIII
IIIW.C
SCHEMATIC SECTION
gully
inspection chamber
vent pipe
NOTESair should be exiuded fromtank to encourage growth ofanacrobic bacteriaflow of effluent
350
I
II
1
350
gully
2
A
B
FF
WIRE BALLOON
4 VENT PIPE