brochure dorman smith dinaldormansmith.com/.../catalogs/product-portfolio-2016.pdf · 2018. 10....

2
OVER 130 YEARS OF ELECTRICAL EXCELLENCE PRODUCT PORTFOLIO 2016 44696183 Capacitor Switching Contactors Conforms to IEC / EN 60947-1 / 4 • Ratings from 2.5kVAR–75kVAR Utilization category – AC 6b Early make contacts with damping resistors Ambient operating temperatures upto 55°C Various coil voltage options Power Factor Correction Capacitors Conforms to IEC 60831-1 & 2 1kVAR - 50kVAR Rated voltage 230-690V, 50/60Hz Special design internal discharge Extruded Aluminum or Powder Coated sheet steel housings Metalized Polypropylene Film with Zn/Al Alloy -25°C /+55°C (Class-D) Detuned Harmonic Reactors Conforms to IEC 60289 Three Phase CRGO core Copper / Aluminum winding options Rated Voltage 400/440 VAC Detuning -5.67%, 7% & 14% 5 kVAR– 100 kVAR Noise Level less than 65dB General Purpose Enclosure Fabricated from sheet steel with options for fully welded or modular construction Enclosure heights from 300mm to 2000mm, widths from 250mm to 1200mm and depths from 150mm to 800mm Sheet steel thickness: 1.2mm to 1.6 mm thickness. 2.0 mm available on request Mounting plate and Gland plate: 1.6mm and 2mm thickness. Mounting plate epoxy powder coated to deep orange as per RAL 2000 Enclosure & gland plate finished with epoxy powder coated paint to RAL 7032. Other colors available on request. Neoprene gaskets for superior and long lasting ingress protection Gland plate provided at bottom for IP 54 & IP 55 Wall mounting brackets available as option Modular enclosures are extendable IP 55 canopies available as option Customized solutions on request Ability to meet special requirements like nonstandard sizes, colors, doors and locking arrangements. Weather Proof Enclosed Isolators Conforms to IEC 60947-3 2, 3P + N & 4 Pole • 240 / 415V AC, 50Hz Range from 20A - 63A IP66 ingress protection, Pollution degree 3 Short circuit making capacity 6kA Padlocking provision in OFF position Drain hole for condensate Low smoke halogen free material Plug-in Busducts 300A, 450A, 700A, 800A & 1000A 1300A & 1600A 2250A & 2500A 3200A, 3500A & 4500A 4000A, 5000A & 6400A Trolley Busbar Feeder Busducts 300A, 450A, 700A, 800A & 1000A 1300A & 1600A 2250A & 2500A 3200A, 3500A & 4500A 4000A, 5000A & 6400A Lighting Busduct TYPES OF BUS DUCTS Dorman Smith Lectrobar Busduct Systems Dorman Smith Lectrobar busducts conform to the latest standard IEC 61439 Type tested / verified and certified by Dekra Fabricated from high strength pure electrolytic tin plated copper providing high conductivity, surface protection and good contact Superior insulation materials namely Teflon coated fiber glass film and fiberglass sheets Busbars wrapped with polyester tape after assembly Nonflammable insulation materials rated Class H Bus duct housings constructed from extruded aluminum profiles Non-magnetic housings ensure excellent heat dissipation and significant reduction in reactance and magnetic flux leakage Designed and tested to operate at 50 0 C without derating Standard casing in IP54. Options for IP55, IP65, and IP67 casings available on request • Manufactured in UAE *All images in this brochure are for illustration only. Actual products may differ.

Upload: others

Post on 08-Sep-2020

18 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Brochure DORMAN SMITH DINALdormansmith.com/.../catalogs/Product-Portfolio-2016.pdf · 2018. 10. 2. · Title: Brochure DORMAN SMITH DINAL Created Date: 2/24/2016 12:21:48 PM

O V E R 1 3 0 Y E A R S O F E L E C T R I C A L E X C E L L E N C E

PRODUCT PORTFOLIO

2016

44696183

Capacitor Switching Contactors• Conforms to IEC / EN 60947-1 / 4• Ratings from 2.5kVAR–75kVAR• Utilization category – AC 6b • Early make contacts with damping resistors • Ambient operating temperatures upto 55°C• Various coil voltage options

Power Factor Correction Capacitors • Conforms to IEC 60831-1 & 2• 1kVAR - 50kVAR• Rated voltage 230-690V, 50/60Hz• Special design internal discharge • Extruded Aluminum or Powder Coated sheet steel housings• Metalized Polypropylene Film with Zn/Al Alloy• -25°C /+55°C (Class-D)

Detuned Harmonic Reactors • Conforms to IEC 60289• Three Phase CRGO core• Copper / Aluminum winding options • Rated Voltage 400/440 VAC • Detuning -5.67%, 7% & 14% • 5 kVAR– 100 kVAR• Noise Level less than 65dB

General Purpose Enclosure• Fabricated from sheet steel with options for fully welded or modular construction • Enclosure heights from 300mm to 2000mm, widths from 250mm to 1200mm and depths from 150mm to 800mm• Sheet steel thickness: 1.2mm to 1.6 mm thickness. 2.0 mm available on request• Mounting plate and Gland plate: 1.6mm and 2mm thickness. • Mounting plate epoxy powder coated to deep orange as per RAL 2000• Enclosure & gland plate finished with epoxy powder coated paint to RAL 7032. Other colors available on request.• Neoprene gaskets for superior and long lasting ingress protection• Gland plate provided at bottom for IP 54 & IP 55• Wall mounting brackets available as option• Modular enclosures are extendable • IP 55 canopies available as option• Customized solutions on request• Ability to meet special requirements like nonstandard sizes, colors, doors and locking arrangements.

Weather Proof Enclosed Isolators • Conforms to IEC 60947-3• 2, 3P + N & 4 Pole• 240 / 415V AC, 50Hz• Range from 20A - 63A • IP66 ingress protection, Pollution degree 3• Short circuit making capacity 6kA• Padlocking provision in OFF position• Drain hole for condensate• Low smoke halogen free material

Plug-in Busducts300A, 450A, 700A, 800A & 1000A1300A & 1600A2250A & 2500A3200A, 3500A & 4500A4000A, 5000A & 6400ATrolley Busbar

Feeder Busducts300A, 450A, 700A, 800A & 1000A

1300A & 1600A2250A & 2500A

3200A, 3500A & 4500A4000A, 5000A & 6400A

Lighting Busduct

TYPES OF BUS DUCTS

Dorman Smith Lectrobar Busduct Systems

• Dorman Smith Lectrobar busducts conform to the latest standard IEC 61439• Type tested / verified and certified by Dekra• Fabricated from high strength pure electrolytic tin plated copper providing high conductivity, surface protection and good contact• Superior insulation materials namely Teflon coated fiber glass film and fiberglass sheets• Busbars wrapped with polyester tape after assembly• Nonflammable insulation materials rated Class H• Bus duct housings constructed from extruded aluminum profiles• Non-magnetic housings ensure excellent heat dissipation and significant reduction in reactance and magnetic flux leakage• Designed and tested to operate at 500C without derating• Standard casing in IP54. Options for IP55, IP65, and IP67 casings available on request• Manufactured in UAE

*All images in this brochure are for illustration only. Actual products may differ.

Page 2: Brochure DORMAN SMITH DINALdormansmith.com/.../catalogs/Product-Portfolio-2016.pdf · 2018. 10. 2. · Title: Brochure DORMAN SMITH DINAL Created Date: 2/24/2016 12:21:48 PM

MODIS and MODIS Ultra (Main Distribution Panel Boards)• Type Tested/Verified Assembly to the latest standard IEC 61439 and certified by ASTA• Ratings up to 6300A• Fault Ratings of 50kA for 1 sec / 3 secs, 80kA for 1 sec and 100kA for 1 sec.• Tested for operation at ambient temperatures of 50°C• Frames formed from 2.5mm sheet steel, 3.0mm available on request• Doors & Covers fabricated from 1.6mm sheet steel, 2.0mm available on request• Forms of segregation upto Form 4 Type 6, Type 7 available on request• Busbars from HDHC Tin Plated Copper• Standard rating of IP43, IP54 available on request• Sheet steel epoxy powder coated to light grey semi-gloss as per RAL 7035 with an average 65 microns paint thickness• Enclosure sections available in widths of 600mm, 800mm & 1000mm, depths of 800mm or 1000mm and a height of 2300mm including an integral plinth

Product Overview

Loadbank (Sub-Main Distribution Boards)• Type Tested / Verified Assembly to the latest standard IEC 61439 and certified by ASTA• Busbars rated for a short circuit withstand of 25kA for 1 sec/3 secs, 36kA for 1 sec and 50kA for 1 Sec • Enclosures formed from 1.2mm sheet steel, epoxy powder coated to light grey semi-gloss as per RAL 7035 with a paint thickness of an average 65 microns • IP41 ingress protection• Option of 250A, 400A and 800A incomers with 4-18 outgoing way configurations• Form 2 & 4 (400A-800A)• Tin Plated HDHC copper busbars• Common width (700mm) and depth (190mm) for 250A incomer• Common width (900mm) and depth (200mm) for 400-800A incomer

Loadcentre (Distribution Boards) • Conforms to IEC / BS EN 61439-3• SP&N and Consumer units• Horizontal distribution - Row Type: 1-6 Row in 10, 12, 14, 16, 18 and 24 Module• TPN Vertical - 4, 6, 8, 10, 12 and 16 Way up to 17kA for 250ms• Various incomer ratings from 63A - 250A (Isolators, RCCBs & MCCBs)• Enclosures formed from 1.0mm sheet steel and doors from 1.2mm• Epoxy powder coated to light grey semi-gloss as per RAL 7035 with a paint thickness of an average 65 microns. Other color options available on request• Tin plated busbars from 100A - 250A for various applications • Various accessories available

Loadcentre Elegance (Distribution Boards) • Conforms to IEC / BS EN 61439-3• SP&N and Consumer units• Horizontal distribution - Row Type: 1-6 Row in 10, 12, 14, 16, 18 and 24 Module• TPN Vertical - 4, 6, 8, 10, 12 and 16 Way up to 17kA for 250ms• Various incomer ratings from 63A - 250A (Isolators, RCCBs & MCCBs)• Enclosures formed from 1.0mm sheet steel and doors from 1.2mm• Epoxy powder coated to light grey semi-gloss as per RAL 7035 with a paint thickness of an average 65 microns. Other color options available on request• Tin plated busbars from 100A - 250A for various applications • Various accessories available

On-Load Changeover Switches • Conforms to IEC 747-3• 4 Pole, 415V AC, 50Hz• 63A - 1000A • AC-23A duty• High mechanical and electrical endurance• Contact mechanism in enclosed housing high ingress against dust• With or without sheet steel enclosure

On-Load Switch Disconnectors • Conforms to IEC 60947-1 & 3• 3 & 4 Pole, 415V AC, 50Hz• 63A - 1000A • AC-23A duty• Direct or extended rotary handle options• With or without sheet steel enclosure

Air Circuit Breakers (ACBs)• Exceeds requirement of IEC 60947-2 & 3• 3 & 4 Pole from 630-6300A in 3 frame sizes• Ics = 100% Icu for all ratings • Fixed and Draw-out options • Breaking capacities 65-100kA • (Ue) - 690V, (Ui) - 1000V, (Uimp) - 12kV • Microprocessor based trip units (OCR) with various options • Horizontal / Vertical terminal connection options available

Residual Current Circuit Breakers with Overcurrent Protection (RCBOs)• Conforms to EN 61009• 6A - 40A• Voltage 230/240V and 400/415V 50/60 Hz• Single Module: Type A • 10kA rated breaking capacity • Terminal Capacity: top terminals 10mm2 & bottom terminals 25mm2

Thermal Overload Relays • Conforms to IEC/EN 60947-4, VDE0660• 0.1A - 400A in various adjustable overload setting ranges• Temperature compensated • Differential tripping• Trip indication• Auto or manual reset selectable• Direct contactor mounting

Power Contactors• Conforms to IEC / EN60947-4-1, IEC / EN 60947-5-1, VDE0660• 9A - 400A in 3 & 4 Pole• Ue 400 / 415V, Ui - 690V• AC3 duty • Coil Voltage AC 24, 48, 110, 230/240, 380/400V, 50Hz / 60Hz and various DC voltage options available• Various aux contact options available• Mechanical Interlocks• Ambient temperature -25°C to +55°C

Timers & Time Switches • Conforms to IEC 60730-1• Range includes 24 Hour, On & Off delay timers etc.• Digital & Analog options available• Staircase timers suitable for incandescent, halogen and fluorescent lighting • AC240V, 50 / 60Hz• Consumption 1VA-2.5VA• Terminal size for cable 2.5mm2

Moulded Case Circuit Breakers (MCCBs)• Exceeds the requirements of EN 60947-2• Ics = 100% Icu for all ratings • Fixed & Adjustable Thermal- Magnetic trip units available• Electronic trip unit options available with / without communication• Wide range from 16A-1250A in various frame sizes • Breaking capacities from 26kA - 150kA, 415/460V AC• 1, 2, 3 & 4 pole execution • 690V AC (Ue) and 750V AC (Ui)• Fully rated for use at 50°C

Miniature Circuit Breakers (MCBs) • Conforms to EN 60898• 0.5A-63A in 1, 2, 3 & 4 poles • 6kA & 10kA, 240V & 415V, 50/60Hz• Contact position indicators• 25mm2 cable capacity• VDE certification

Residual Current Circuit Breakers (RCCBs)• Conforms to EN 61008• 25-100A, 2 & 4 Pole • Equipped with Transient Suppression Filter• Voltage 230/240V & 400/415V, 50/60Hz• Type AC• Terminal capacity: Top 25mm2 & Bottom 35mm2

Switch Disconnector (Modular Isolators)• Conforms to EN 60947-3• 50mm2 cable capacity • AC22, 240V & 415V 50 / 60Hz

Modular Contactors • Conforms to IEC / EN 60947-4, IEC / EN 61095• 10, 16, 20, 25, 32, 40 & 63A in 2, 3 & 4 Pole • AC-7a & 7b duty• IP20 Protection • Various aux contact options

• Contact mechanism in enclosed housing high ingress 125A