bs 2000 2000g 2416 3416 gre pipe systems for industrial and oilfield services

28
8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 1/28

Upload: nadeem-ahmed

Post on 02-Jun-2018

245 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 1/28

Page 2: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 2/28

2

Table of Contents GENERAL DATA

 Adhesive ............................................................................................................... 20

Bending radius (minimal allowable) ...................................................................... 7

Conversions .........................................................................................................27

Engineering design & installation data ................................................................ 27

Field testing ..........................................................................................................27

Important notice ................................................................................................... 27

Joining system and configuration ......................................................................... 3

Typical mechanical properties ...............................................................................4

Typical physical properties .................................................................................... 4

Pipe series .............................................................................................................. 3

Typical pipe length ................................................................................................. 4

Typical pipe dimensions and weights.................................................................... 6

Typical pipe performance ...................................................................................... 5

Span length (for horizontal support) ..................................................................... 7Surge pressure .................................................................................................... 27

TAPER/TAPER FITTINGS DATA

Couplings ............................................................................................................. 18

Elbows ................................................................................................................ 8-9

Flanges.......................................................................................................16-17-18

Taper/Taper dimensions ......................................................................................... 8

Nipples ................................................................................................................. 19

Reducers .........................................................................................................14-15

Saddles .....................................................................................................12-13, 19

Specials ................................................................................................................ 27

Stub-ends ............................................................................................................. 17

Tees ............................................................................................................10-11-12

KEY-LOCK FITTINGS DATA

 Adapter ................................................................................................................26

Couplings ............................................................................................................ 24

Elbows ............................................................................................................21-22

Flanges................................................................................................................. 24

Key-Lock dimensions ........................................................................................... 21

Nipples ................................................................................................................. 25

Tees ................................................................................................................. 22-23

Page 3: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 3/28

 3

Pipe series PipeFilament-wound Glassfiber Reinforced Epoxy (GRE) pipe for Bondstrand Taper/Taperadhesive-bonded joint or Key-Lock mechanical joint pipe systems.MDA (diaminodiphenylmethane) or IPD (isophoronediamine) cured.

Fittings A wide range of lined filament-wound Glassfiber Reinforced Epoxy (GRE) fittings forBondstrand Taper/Taper adhesive-bonded joint systems. For special fittings, not listed inthis product guide, please contact your NOV FGS representative.

Flanges

Filament-wound Glassfiber Reinforced Epoxy (GRE) heavy-duty and stub-end flangesfor Bondstrand adhesive bonded joint systems. Standard flange drilling patterns as per

 ANSI B16.5 / B16.47 A (150 Lb). Other flange drilling patterns, such as ANSI B16.5 /B16.47 A (> 150 Lb), DIN, ISO and JIS are also available.

Bondstrand® 2416/3416Glassfiber Reinforced Epoxy (GRE) pipe system;Unlined or with 0.5 mm internal resin-rich reinforced liner;Maximum operating temperature: 93°C or 121°C depending on the curing system;Maximum pressure rating: 16 bar.

ConductiveConductive pipe systems are available to prevent accumulation of potentially dangerouslevels of static electrical charges. Pipe, fittings and flanges contain high strengthconductive filaments. Together with a conductive adhesive this provides an electricallycontinuous system.

Description Bondstrand Bondstrand   2416* 3416*

Pipe Diameter 2-40 inch 2-40 inchJoining system Taper/Taper Taper/Taper  Key-Lock Key-LockLiner** 0.5 mm 0.5 mmTemperature 121 °C*** 93 °C Pressure rating 16 bar 16 bar * Also available in conductive version

** Also available without liner

*** Above 93°C, derate the pressure rating lineairly to 50% at 121°C

Key-Lock systems are suitable for a maximum temperature of 93°C 

Pipe and fittings are available with a Taper/Taper adhesive bonded joint or a Key-Lockmechanical joint with O-ring seal.

Pipe50-1000 mm (2-40 inch):Taper/Taper adhesive joint;End configuration: Integral Taper socket x Taper spigot.50-600 mm (2-24 inch):Key-Lock mechanical joint;End configuration: Integral Key-Lock socket x Integral Key-Lock spigot.

Fitting50-1000 mm (2-40 inch):Taper/Taper adhesive joint.End configuration: Integral Taper socket ends.50-600 mm (2-24 inch):Key-Lock mechanical joint;End configuration: Integral Key-Lock socket ends.

Flange50-1000 mm (2-40 inch):Taper/Taper adhesive joint.

End configuration: Integral Taper socket end.

50-600 mm (2-24 inch):

Key-Lock mechanical joint;

End configuration: Key-Lock spigot.

Note: Pipe nipples, saddles and flanged fittings have different end configurations.

Joining system &configuration

Page 4: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 4/28

4

Typical pipe length

Typical physicalproperties

Typical mechanicalproperties

Nominal Joining Approximate overall

Length* System

Pipe Size Europe Plant Asia Plant

[mm] [inch] [m] [m]

50-150 2-6 Taper/Taper 6.1 9.0

200-600 8-24 Taper/Taper 6.1/11.8 11.89

700-1000 28-40 Taper/Taper 11.8 11.89

50-150 2-6 Key-Lock 6.10 9.0

200-600 8-24 Key-Lock 6.10/11.8 11.89

* Tolerance +/- 50 mm.

Pipe property 3416  Units 21°C 93°C Method

Bi-axial 

Ultimate hoop stress at weeping N/mm2 300 — ASTM D-1599

Circumferential 

Hoop tensile strength N/mm2 380 — ASTM D-2290Hoop tensile modulus N/mm2 23250 18100 ASTM D-2290

Poisson’s ratio axial/hoop — 0.93 1.04 NOV FGS

Longitudinal 

 Axial tensile strength N/mm2 65 50 ASTM D-2105

 Axial tensile modulus N/mm2 10000 7800 ASTM D-2105

Poisson’s ratio hoop/axial — 0.40 0.45 ASTM D-2105

 Axial bending strength — 80 — NOV FGS

Beam 

 Apparent elastic modulus N/mm2 9200 7000 ASTM D-2925

Hydrostatic Design Basis 

Static N/mm2 148* — ASTM D-2992

  (Proc. B.)

* At 65°C.

Pipe property  2416  Units 21°C 93°C Method

Bi-axial 

Ultimate hoop stress at weeping N/mm2 250 — ASTM D-1599

Circumferential 

Hoop tensile strength N/mm2 220 — ASTM D-2290

Hoop tensile modulus N/mm2 25200 ASTM D-2290

Poisson’s ratio axial/hoop — 0.65 0.81 NOV FGS

Longitudinal 

 Axial tensile strength N/mm2 80 65 ASTM D-2105

 Axial tensile modulus N/mm2 12500 9700 ASTM D-2105

Poisson’s ratio hoop/axial — 0.40 0.44 ASTM D-2105

 Axial bending strength — 85 — NOV FGS

Beam  Apparent elastic modulus N/mm2 12500 8000 ASTM D-2925

Hydrostatic Design Basis 

Static N/mm2 — 124 ASTM D-2992

  (Proc. B.)

 

Pipe property Units Value Method

Thermal conductivity pipe wall W(m.K) .33 NOV FGS

Thermal expansion coefficient 10-6 mm/mm °C 18.0 NOV FGS

Flow coefficient Hazen-Williams 150

 Absolute roughness 10-6 m 5.3 —

Density kg/m3 1800 —

Specific gravity - 1.8 ASTM D-792

Page 5: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 5/28

 5

Bondstrand 2416 at 21°C

Nominal Internal Ultimate STIS Stifness Pipe

Pipe Pressure Collapse Factor Stiffness

Size *Rating **Pressure ***(SF) ***(PS)

[mm] [inch] [bar] [bar] [kN/m2] [lb.in] [psi]

50 2 16 17.9 73.6 108 573

80 3 16 5.0 21.0 108 163

100 4 16 3.3 13.6 149 106

150 6 16 2.9 12.1 453 94200 8 16 2.7 11.1 941 86

250 10 16 2.6 10.7 1809 83

300 12 16 2.6 10.7 3092 84

350 14 16 2.7 11.1 4218 86

400 16 16 2.6 10.7 6105 84

450 18 16 2.6 10.7 8158 83

500 20 16 2.5 10.5 11015 82

600 24 16 2.5 10.6 19148 83

700 28 16 2.5 10.3 32924 80

750 30 16 2.5 10.4 40831 81

800 32 16 2.5 10.2 48843 80

900 36 16 2.4 10.2 69208 791000 40 16 2.5 10.3 96228 80

* At 93°C using NOV FGS approved adhesive;** No safety factor included;*** Per ASTM D-2412.

Typical pipeperformance

Bondstrand 3416 at 21°C

Nominal Internal Ultimate STIS Stifness Pipe

Pipe Pressure Collapse Factor Stiffness

Size *Rating **Pressure ***(SF) ***(PS)

[mm] [inch] [bar] [bar] [kN/m2] [lb.in] [psi]

50 2 16 16.5 73.9 109 575

80 3 16 4.6 21.0 109 164

100 4 16 3.0 13.7 149 107

150 6 16 1.7 7.8 292 61

200 8 16 1.3 6.0 504 47

250 10 16 1.3 6.1 1024 47

300 12 16 1.3 6.0 1700 46

350 14 16 1.3 5.8 2195 45

400 16 16 1.3 5.8 3277 45

450 18 16 1.3 5.9 4447 46

500 20 16 1.3 5.9 6130 46600 24 16 1.3 5.8 10288 45

700 28 16 1.3 5.9 18659 46

750 30 16 1.3 5.8 22858 46

800 32 16 1.3 5.8 27644 46

900 36 16 1.3 5.8 39130 45

1000 40 16 1.3 5.8 53425 45

* At 93°C using NOV FGS approved adhesive;** No safety factor included;*** Per ASTM D-2412.

Page 6: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 6/28

6

Typical pipe dimensionsand weights

Bondstrand 2416

Nominal Pipe Minimum Average Designation per

Pipe Inside Structural Wall Pipe ASTM

Size Diameter *Thickness [t] Weight D-2996

[ mm] [inch] [mm] [mm] [kg/m] (RTRP-11...)

50 2 53.0 1.8 0.7 FX1-2111

80 3 81.8 1.8 1.0 FX1-2111

100 4 105.2 2.0 1.4 FX1-2111

150 6 159.0 2.9 3.0 FX1-2112200 8 208.8 3.7 4.9 FX1-2112

250 10 262.9 4.6 7.5 FX1-2114

300 12 313.7 5.5 10.6 FX1-2116

350 14 344.4 6.1 12.8 FX1-2116

400 16 393.7 6.9 16.4 FX1-2116

450 18 433.8 7.6 19.8 FX1-2116

500 20 482.1 8.4 24 FX1-2116

600 24 578.6 10.1 35 FX1-2116

700 28 700.0 12.1 50 FX1-2116

750 30 750.0 13.0 58 FX1-2116

800 32 800.0 13.8 65 FX1-2116

900 36 900.0 15.5 82 FX1-2116

1000 40 1000.0 17.3 102 FX1-2116

* Excluding liner thickness.

Bondstrand 3416

Nominal Pipe Minimum Average Designation per

Pipe Inside Structural Wall Pipe ASTM

Size Diameter *Thickness [t] Weight D-2996[mm] [inch] [mm] [mm] [kg/m] (RTRP-11...)

50 2 53.0 1.8 0.7 FX1-2111

80 3 81.8 1.8 1.0 FX1-2111

100 4 105.2 2.0 1.4 FX1-2111

150 6 159.0 2.5 2.6 FX1-2112

200 8 208.8 3.0 4.0 FX1-2112

250 10 262.9 3.8 6.2 FX1-2113

300 12 313.7 4.5 8.7 FX1-2114

350 14 344.4 4.9 10.4 FX1-2115

400 16 393.7 5.6 13.4 FX1-2116

450 18 433.8 6.2 16.3 FX1-2116

500 20 482.1 6.9 20 FX1-2116

600 24 578.6 8.2 28 FX1-2116

700 28 700.0 10.0 42 FX1-2116

750 30 750.0 10.7 48 FX1-2116

800 32 800.0 11.4 54 FX1-2116

900 36 900.0 12.8 68 FX1-2116

1000 40 1000.0 14.2 83 FX1-2116

* Excluding liner thickness.

Page 7: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 7/28

 7

Span length  Horizontal support for Bondstrand 2416 and 3416 at 21 °C

Nominal Single Continuous Single ContinuousPipe Span* Span* Span* Span*Size 2416 2416 3416 3416[mm] [inch] [m] [m] [m] [m]50 2 2.9 3.6 2.6 3.480 3 3.2 4.1 3.0 3.8100 4 3.5 4.5 3.2 4.1150 6 4.2 5.3 3.8 4.8

200 8 4.7 6.0 4.2 5.4250 10 5.3 6.7 4.7 6.0300 12 5.7 7.3 5.1 6.5350 14 6.0 7.7 5.3 6.8400 16 6.4 8.1 5.7 7.2450 18 6.7 8.5 6.0 7.6500 20 7.1 9.0 6.3 8.0600 24 7.7 9.8 6.8 8.7700 28 8.5 10.7 7.5 9.5750 30 8.8 11.1 7.8 9.9800 32 9.0 11.5 8.0 10.2900 36 9.6 12.1 8.5 10.81000 40 10.1 12.8 8.9 11.3

* Span recommendations are based on pipes filled with water having a density of 1000 kg/m3 andinclude no provisions for weights caused by valves, flanges or other heavy objects. At 93°C,

span lengths are approx. 10% lower.

Bending Radius  Minimum allowable for Bondstrand 2416 and 3416 at 21 °C

Nominal Bending BendingPipe Radius Radius

Size 3416 2416[mm] [inch] [m] [m]50 2 11 12

80 3 20 25

100 4 27 42

150 6 53 52

200 8 83 67

250 10 103 87

300 12 125 106

350 14 139 116

400 16 159 135

450 18 173 150

500 20 192 169

600 24 235 204

700 28 279 253750 30 300 271

800 32 321 291

900 36 362 330

1000 40 404 366

Note: Do not bend pipe until adhesive has cured. Sharper bends may create excessive

stress concentrations.

Page 8: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 8/28

8

Filament-wound 90° elbows with integral Taper/Taper (2-40 inch) socket ends for

adhesive bonding.

Nominal Laying Overall Average

Pipe Size Length (LL) Length (OL) Weight

[mm] [inch] [mm] [mm] [kg]

50 2 87 137 0.6

80 3 126 176 1.1

100 4 155 205 2.1

150 6 240 290 4,2

200 8 315 395 12

250 10 391 501 16

300 12 463 603 26

350 14 364 504 37

400 16 402 572 53

450 18 472 642 76500 20 523 723 125

600 24 625 855 228

700 28 726 956 238

750 30 777 1037 290

800 32 828 1118 364

900 36 929 1279 544

1000 40 1040 1360 610

Elbows 90°

Taper/Taperdimensions

Dimensions for adhesive Taper Spigots for adhesive Taper/Taper (2-40 inch) joints.

Nominal Taper Insertion Nominal Dia of 

Pipe Angle Depth Spigot Spigot

Size Nose Thickn. at Nose

  X Ds nose Sd

[mm] [inch] [degrees] [mm] [mm] [mm]

50 2 1.75 50 1.0 55.2

80 3 1.75 50 1.0 83.8

100 4 1.75 50 1.0 107.2150 6 2.5 50 1.0 161.0

200 8 2.5 80 1.0 210.8

250 10 2.5 110 1.0 264.9

300 12 2.5 140 1.0 315.7

350 14 2.5 140 1.5 347.4

400 16 2.5 170 1.5 396.7

450 18 2.5 170 1.5 436.8

500 20 2.5 200 2.0 486.1

600 24 2.5 230 2.5 583.6

700 28 1.75 230 5.5 711.0

750 30 1.75 260 6.0 762.0

800 32 1.75 290 5.5 811.0900* 36 1.75 350 6.0 912.0

900** 36 1.75 260 6.0 912.0

1000* 40 1.75 320 8.0 1016.0

1000** 40 1.75 230 8.0 1016.0

* For Bondstrand 2416 pipe joint and fitting joint.** For Bondstrand 3416 pipe joint only.

Page 9: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 9/28

 9

Elbows 22½° Filament-wound 22½° elbows with integral Taper/Taper (2-40 inch) socket ends for

adhesive bonding.

Nominal Laying Overall Average

Pipe Length Length Weight

Size (LL) (OL)

[mm] [inch] [mm] [mm] [kg]

50 2 29 79 0.4

80 3 37 87 0.6

100 4 43 93 0.9

150 6 60 110 1.4

200 8 76 156 5.1

250 10 68 178 9.7

300 12 77 217 15.5

350 14 71 211 21

400 16 85 255 24450 18 106 276 39

500 20 116 316 56

600 24 136 366 93

700 28 157 387 123

750 30 167 427 158

800 32 177 467 198

900 36 197 547 343

1000 40 234 554 410

Elbows 45° Filament-wound 45° elbows with integral Taper/Taper (2-40 inch) socket ends for

adhesive bonding.

Nominal Laying Overall Average

Pipe Length Length Weight

Size (LL) (OL)

[mm] [inch] [mm] [mm] [kg]

50 2 45 95 0.5

80 3 61 111 0.9

100 4 73 123 1.3150 6 106 156 2,5

200 8 137 217 7,4

250 10 169 279 12,4

300 12 196 336 22

350 14 125 265 29

400 16 142 312 41

450 18 204 374 54

500 20 225 425 75

600 24 268 498 130

700 28 310 540 177

750 30 331 591 226

800 32 352 642 272900 36 394 744 463

1000 40 450 770 530

Page 10: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 10/28

10

Nominal Laying Overall Laying Overall Average

Pipe Length Length Length Length Weight

Size total run total run branch branch

(LL1) (OL1) (LL2) (OL2)

[mm] [inch] [mm] [mm] [mm] [mm] [kg]

50 2 148 248 74 124 1.3

80 3 192 292 96 146 2.9100 4 230 330 115 165 4.0

150 6 306 406 153 203 8.7

200 8 376 536 188 268 21

250 10 452 672 226 336 31

300 12 528 808 264 404 50

350 14 544 824 272 412 55

400 16 590 930 295 465 87

450 18 678 1018 339 509 103

500 20 740 1140 370 570 209

600 24 868 1328 434 664 351

700 28 994 1454 497 727 476

750 30 1046 1566 523 783 591

800 32 1118 1698 559 849 727

900 36 1248 1948 624 974 1213

1000 40 1416 2056 708 1028 1577

Equal Tees Filament-wound equal Tee with integral Taper/Taper (2-40 inch) socket ends foradhesive bonding. 

Reducing Tees

Standard 

Fabricated 

Note: Regular numbers are filament wound tees; Italic numbers are fabricated.

Filament-wound standard and fabricated  reducing tees with integral Taper/Taper(2-36 inch) socket ends for adhesive bonding.

Nominal Laying Overall Laying Overall Average

Pipe Length Length Length Length WeightSize (LL1) (OL1) (LL2) (OL2)

(runxrunxbranch) half run half run branch

[mm] [inch] [mm] [mm] [mm] [mm] [kg]

80x80x50 3x3x2 96 146 86 136 2.7

100x100x50 4x4x2 115 165 99 149 3.8

100x100x80 4x4x3 115 165 108 158 4.0

150x150x50 6x6x2 153 203 124 174 8.0

150x150x80 6x6x3 153 203 134 184 9.6

150x150x100 6x6x4 153 203 140 190 9.6

200x200x50 8x8x2 88 168 179 229 24.6

200x200x80 8x8x3 188 268 159 209 16.0

200x200x100 8x8x4 188 268 172 222 16.7

200x200x150 8x8x6 188 268 178 228 13.2250x250x50 10x10x2 88 198 206 256 30

250x250x80 10x10x3 100 210 206 256 32

250x250x100 10x10x4 226 336 194 244 29

250x250x150 10x10x6 226 336 204 254 28

250x250x200 10x10x8 226 336 213 293 34

300x300x50 12x12x2 88 228 232 282 35

300x300x80 12x12x3 100 240 232 282 37 

300x300x100 12x12x4 264 404 216 266 43

300x300x150 12x12x6 264 404 229 279 42

300x300x200 12x12x8 264 404 239 319 45

300x300x250 12x12x10 264 404 251 361 51

350x350x50 14x14x2 88 228 247 297 37 

350x350x80 14x14x3 100 240 247 297 40

Page 11: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 11/28

 11

Note: Regular numbers are filament wound tees; Italic numbers are fabricated

Standard 

Fabricated 

Reducing Tees (C’tnd) Filament-wound standard and fabricated reducing tees with integral Taper/Taper(2-36 inch) socket ends for adhesive bonding. Nominal Laying Overall Laying Overall AveragePipe Length Length Length Length WeightSize (LL1) (OL1) (LL2) (OL2)(runxrunxbranch) half run half run branch[mm] [inch] [mm] [mm] [mm] [mm] [kg]

350x350x100 14x14x4 113 253 247 297 43

350x350x150 14x14x6 272 412 254 304 41

350x350x200 14x14x8 272 412 264 344 54350x350x250 14x14x10 272 412 277 387 62

350x350x300 14x14x12 272 412 289 429 66

 400x400x50 16x16x2 88 258 272 322 50

 400x400x80 16x16x3 100 270 272 322 53

400x400x100 16x16x4 113 283 272 322 56

400x400x150 16x16x6 295 465 274 324 51

400x400x200 16x16x8 295 465 283 363 56

400x400x250 16x16x10 295 465 293 403 63

400x400x300 16x16x12 295 465 305 445 67

400x400x350 16x16x14 295 465 315 455 71

 450x450x50 18x18x2 88 258 292 342 54

 450x450x80 18x18x3 100 270 292 342 58

 450x450x100 18x18x4 113 283 292 342 61450x450x200 18x18x8 339 509 316 396 100

450x450x250 18x18x10 339 509 329 439 104

450x450x300 18x18x12 339 509 329 469 107

450x450x350 18x18x14 339 509 330 470 137

450x450x400 18x18x16 339 509 330 500 143

500x500x50 20x20x2 88 288 316 366 59

500x500x80 20x20x3 100 300 316 366 63

500x500x100 20x20x4 113 313 316 366 67 

500x500x200 20x20x8 370 570 350 430 175

500x500x250 20x20x10 370 570 355 465 180

500x500x300 20x20x12 370 570 355 495 186

500x500x350 20x20x14 370 570 356 496 188

500x500x400 20x20x16 370 570 356 526 195500x500x450 20x20x18 370 570 365 535 200

600x600x50 24x24x2 88 318 364 414 71

600x600x80 24x24x3 100 330 364 414 75

600x600x100 24x24x4 113 343 364 414 80

600x600x300 24x24x12 434 664 405 545 211

600x600x350 24x24x14 434 664 406 546 281

600x600x400 24x24x16 434 664 406 576 220

600x600x450 24x24x18 434 664 428 598 239

600x600x500 24x24x20 434 664 428 628 279

700x700x50 28x28x2 88 318 425 475 97 

700x700x80 28x28x3 100 330 425 475 102

700x700x100 28x28x4 113 343 425 475 107 

700x700x350 28x28x14 497 727 475 615 413

700x700x400 28x28x16 497 727 483 655 423

700x700x450 28x28x18 497 727 483 653 428

700x700x500 28x28x20 497 727 491 691 440

700x700x600 28x28x24 497 727 491 721 458

750x750x50 30x30x2 88 348 450 500 103

750x750x80 30x30x3 100 360 450 500 109

750x750x100 30x30x4 113 373 450 500 114

750x750x350 30x30x14 532 783 501 641 506

750x750x400 30x30x16 532 783 501 671 516

750x750x450 30x30x18 532 783 509 679 522

750x750x500 30x30x20 532 783 509 709 534

750x750x600 30x30x24 532 783 517 747 555

750x750x700 30x30x28 532 783 517 747 573

Page 12: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 12/28

12

Filament-wound pipe saddles with stainless steel, ½ inch or ¾ inch threaded

bushings.*

Nominal Angle Saddle Saddle Average Required

Pipe Length Thickn. Weight Adhesive

Size α  (B) (ts) Kits

[mm] [inch] [degree] [mm] [mm] [kg] [3 Oz] [6 Oz]

50 2 180 100 14 0.5 1 -

80 3 180 100 14 0.6 1 -

100 4 180 100 14 0.8 1 -

150 6 180 100 14 1 - 1

200 8 180 100 14 1,2 - 1

250 10 180 100 14 1,6 1 1

300 12 180 100 14 1,9 1 1

350 14 180 100 14 2,1 1 1

400 16 180 100 14 2,5 - 2

450 18 90 100 14 3,3 - 1

500 20 90 100 14 3,7 1 1

600 24 90 100 14 4,4 - 2

Bushing Saddles

* Consult NOV FGS for other type material, or other sized bushings.

Reducing Tees (C’tnd)

Standard 

Fabricated 

Note: Regular numbers are filament wound tees; Italic numbers are fabricated

Filament-wound standard and fabricated  reducing tees with integral Taper/Taper(2-36 inch) socket ends for adhesive bonding.

Nominal Laying Overall Laying Overall Average

Pipe Length Length Length Length Weight

Size (LL1) (OL1) (LL2) (OL2)

(runxrunxbranch) half run half run branch

[mm] [inch] [mm] [mm] [mm] [mm] [kg]

80x80x50 3x3x2 96 146 86 136 2.7

100x100x50 4x4x2 115 165 99 149 3.8

100x100x80 4x4x3 115 165 108 158 4.0

150x150x50 6x6x2 153 203 124 174 8.0

150x150x80 6x6x3 153 203 134 184 9.6

150x150x100 6x6x4 153 203 140 190 9.6

200x200x50 8x8x2 88 168 179 229 24.6

200x200x80 8x8x3 188 268 159 209 16.0

200x200x100 8x8x4 188 268 172 222 16.7

200x200x150 8x8x6 188 268 178 228 13.2

250x250x50 10x10x2 88 198 206 256 30

250x250x80 10x10x3 100 210 206 256 32

250x250x100 10x10x4 226 336 194 244 29

250x250x150 10x10x6 226 336 204 254 28

250x250x200 10x10x8 226 336 213 293 34

300x300x50 12x12x2 88 228 232 282 35

300x300x80 12x12x3 100 240 232 282 37 

300x300x100 12x12x4 264 404 216 266 43

300x300x150 12x12x6 264 404 229 279 42

300x300x200 12x12x8 264 404 239 319 45

300x300x250 12x12x10 264 404 251 361 51

Page 13: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 13/28

 13

* Dimension based on Quick-Lock flange.

Fabricated flanged reducing saddles (2-24 inch).

Nominal Laying Saddle Saddle   AveragePipe   Length* Length Angle   WeightSize   (LL) (B) α with flange(runxbranch)   CL150[mm]   [inch]   [mm] [mm]   [deg] [kg]50x25 2x1   133   152   180 0.980x50 3x1   133   152   180 0.980x40 3x1½   133   152   180   1.280x50 3x2 174 152   180 1.9

100x25 4x1 152 152   180 1.6100x40 1x1½ 152 152   180 1.7100x50 4x2 194 152   180   2.4150x25 6x1   187   152   180   2.7150x40 6x1½   187   152   180   2.7150x50 6x2 229 152   180 3.3200x25 8x1 206 152   180 3.9200x40 8x1½ 206 152   180 3.9200x50 8x2 248 152   180   4.5250x25 10x1 232 152   180   4.7250x40 10x1½ 232 152   180   4.7250x50 10x2 274 152   180 5.3300x25 12x1 264 152   180   5.4300x40 12x1½ 264 152   180   5.4300x50 12x2   306   152   180 6.0

350x25 14x1 279 152   180 5.9350x40 14x1½ 279 152   180 5.8350x50 14x2 321 152   180   6.4400x25 16x1   305   152   180 6.6400x40 16x1½   305   152   180 6.6400x50 16x2 347 152   180   7.2450x25 18x1   330   152   90 3.8450x40 18x1½   330   152   90 3.8450x50 18x2 372 152   90   4.4500x25 20x1   356   152   90   4.2500x40 20x1½   356   152   90   4.2500x50 20x2   399   152   90   4.8600x25 24x1 406 152   90   4.9600x40 24x1½ 406 152   90   4.9600x50 24x2 448 152   90 5.5

 

Flanged ReducingSaddles

α

4

Page 14: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 14/28

14

Concentric Reducers Filament-wound concentric reducers with integral Taper/Taper (2-36 inch) socket ends

for adhesive bonding.

Nominal Laying Overall Average

Pipe Length Length Weight

Size (LL) (OL)

(runxrun)

[mm] [inch] [mm] [mm] [kg]

80x50 3x2 74 174 0.8

100x50 4x2 96 196 1.1100x80 4x3 94 194 1.3

150x80 6x3 117 217 1.5

150x100 6x4 124 224 1.8

200x100 8x4 163 293 4.3

200x150 8x6 129 259 4.3

250x150 10x6 148 308 6.2

250x200 10x8 135 325 6.9

300x200 12x8 180 400 9.9

300x250 12x10 167 417 10.8

350x250 14x10 214 464 17.0

350x300 14x12 208 488 16.8

400x300 16x12 195 505 22

400x350 16x14 183 493 23450x400 18x16 128 468 27

500x400 20x16 249 619 36

500x450 20x18 151 521 35

600x400 24x16 486 886 70

600x450 24x18 388 788 70

600x500 24x20 267 697 70

700x400 28x16 796 1196 141

700x450 28x18 698 1098 140

700x500 28x20 577 1007 142

700x600 28x24 340 800 142

750x400 30x16 915 1345 177

750x450 30x18 817 1247 175

750x500 30x20 696 1156 177

750x600 30x24 459 949 177

750x700 30x28 149 639 165

800x400 32x16 1038 1498 216

800x450 32x18 940 1400 214

800x500 32x20 819 1309 217

800x600 32x24 582 1102 217

800x700 32x28 272 792 203

800x750 32x30 153 703 207

900x450 36x18 1186 1706 358

900x500 36x20 1065 1615 362

900x600 36x24 828 1408 361

900x700 36x28 518 1098 300900x750 36x30 399 1009 304

900x800 36x32 276 916 307

Page 15: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 15/28

 15

Filament-wound eccentric reducers with integral Taper/Taper (2-36 inch) socket ends.

Nominal Laying Overall Eccentricity Average

Pipe Size Length Length Weight

(runxrun) (LL) (OL) (X)

[mm] [inch] [mm] [mm] [mm] [kg]

80x50 3x2 140 240 14 0.8

100x50 4x2 225 325 27 1.1

100x80 4x3 120 220 12 1.3150x80 6x3 320 420 38 9.8

150x100 6x4 230 330 27 5.3

200x100 8x4 415 545 52 11.1

200x150 8x6 215 345 25 9.0

250x150 10x6 420 580 52 9.6

250x200 10x8 235 425 27 10

300x200 12x8 420 640 52 29

300x250 12x10 220 470 25 11

350x250 14x10 340 590 41 27

350x300 14x12 150 430 16 22

400x300 16x12 335 645 41 61

400x350 16x14 215 525 25 22450x350 18x14 365 675 45 23

450x400 18x16 180 520 20 90

500x400 20x16 365 735 45 87

500x450 20x18 215 585 25 75

600x400 24x16 725 1125 93 115

600x450 24x18 575 975 73 90

600x500 24x20 390 820 48 142

700x400 28x16 1195 1595 156 416

700x450 28x18 1045 1445 136 153

700x500 28x20 860 1290 111 223

700x600 28x24 500 960 63 191

750x400 30x16 1380 1810 181 259

750x450 30x18 1235 1665 161 205

750x500 30x20 1050 1510 136 186

750x600 30x24 690 1180 88 134

750x700 30x28 220 710 25 96

800x600 32x24 875 1395 113 178

800x700 32x28 405 925 50 142

800x750 32x30 220 770 25 118

900x600 36x24 1250 1830 163 284

900x700 36x28 780 1360 100 260

900x750 36x30 590 1200 75 243

900x800 36x32 405 1045 50 271

 

Eccentric Reducers

Page 16: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 16/28

16

Filament-wound heavy-duty flanges with integral Taper/Taper (2-24 inch) socket end for

adhesive bonding.

Nominal Laying Overall Average weight

Pipe Length Length ANSI ANSI DIN

Size (LL) (OL) B16.5 B16.5 2633

  B16.47A B16.47A

  CL.150 CL.300 PN16

[mm] [inch] [mm] [mm] [kg] [kg] [kg]

50 2 5 55 1.5 1.9 1.980 3 5 55 2.2 2.8 2.5

100 4 5 55 2.9 4.1 2.8

150 6 5 55 3,7 5.5 4.2

200 8 6 86 8,4 11.9 8.3

250 10 6 116 14,3 20 14.5

300 12 6 116 21 27 17.3

350 14 6 116 25 35 23

400 16 6 146 38 52 35

450 18 6 146 41 63 43

500 20 6 176 58 82 61

600 24 6 206 66 - -

Note:• Other drillings may be possible. Please consult NOV FGS;

• Full-face elastomeric gaskets may be used suitable for the service pressure, service

temperature and fluid. Shore A durometer hardness of 60 ±5 is recommended (3 mm thick).

Compressed fibre gaskets (3 mm thick), compatible with pressure, temperature and medium

may also be used. Mechanical properties should be in accordance with DIN 3754 (IT 400)

or equal;

• For maximum bolt torque refer to the appropriate Bondstrand literature;

•  A torque-wrench must be used, since excessive torque may result in flange damage.

Heavy-Duty Flanges

Page 17: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 17/28

 17

Filament-wound stub-ends, O-ring sealed or flat faced, with integral Taper/Taper

(2-40 inch) socket end, for adhesive bonding with loose steel ring flanges.

Nominal Laying Overall Face Ring Average

Pipe Length Length Diameter to Face Weight

Size (LL) (OL) (RF) (H) Stub-end

[mm] [inch] [mm] [mm] [mm] [mm] [kg]

50 2 15 65 92 10 0.2

80 3 15 65 127 10 0.5

100 4 15 65 157 12 0.8150 6 15 65 216 13 1.3

200 8 15 95 270 20 2.6

250 10 15 125 324 23 4.0

300 12 15 155 378 26 5.9

350 14 15 155 413 27 5.8

400 16 20 190 470 32 9.6

450 18 20 190 532 35 16.1

500 20 20 220 580 39 19.8

600 24 20 250 674 47 22

700 28 20 250 800 51 26

750 30 20 280 850 46 29

800 32 20 310 900 48 34900 36 20 370 1000 53 41

1000 40 20 250 1100 69 44

Note:• Flat faced stub-ends can be sealed using reinforced elastomeric, compressed fiber or steel

reinforced rubber gaskets, depending on size;• Make sure that when using O-ring sealed stub-end, its counter flange is compatible, e.g. use a

flat faced stub-end (without O-ring groove) or another flat surface flange as counter flange.

 Nominal ANSI Average ANSI Average DIN 2633 Average

Pipe B16.5/ Weight B16.5/ Weight Weight

  B16.47 A B16.47 A

Size CLASS.150 CLASS.300 PN 16

(D) (D) (D)

[mm] [inch] [mm] [kg] [mm] [kg] [mm] [kg]

50 2 19.0 1.8 22.2 2.5 18 2.2

80 3 23.8 3.2 28.6 4.8 20 3.0

100 4 23.8 4.2 28.6 7.0 20 3.1

150 6 25.5 5.2 36.5 12.2 23 5.1

200 8 28.8 8.5 41.3 18.3 27 7.3

250 10 35.6 13.5 47.6 26 32 11.8300 12 40 23 50.8 39 35 15.4

350 14 41.6 32 54 56 40 26

400 16 47.9 42 58.2 70 44 33

450 18 50.2 40 63.6 87 50 41

500 20 52 51 66.5 104 54 60

600 24 63.7 86 78.4 183 63 72

700 28 69 100 95 213 59 102

750 30 71.6 117 99.9 229 - -

800 32 76.9 154 106 289 66 106

900 36 85.4 197 117.7 424 71 125

1000 40 94 303 103 439 82 291

Note:• Ring flanges will standard be made from galvanised steel. Other materials are available onrequest;

• Other drillings are available. Please consult NOV FGS;• For maximum bolt-torque please refer to the appropriate Bondstrand Literature.

Steel Ring Flanges forStub-ends

Stub-ends

Page 18: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 18/28

18

Compression molded blind flanges.

Nominal Flange Average Weight Average Weight Average Weight

Pipe Thickness ANSI B16.5 ANSI B16.5 DIN 2633

  B16.47A B16.47A

Size (D) CLASS 150 CLASS 300 PN 16

[mm] [inch] [mm] [kg] [kg] [kg]

50 2 30 0.7 1.2 1.2

80 3 30 1.1 1.9 1.7

100 4 35 1.7 3.6 2.7150 6 40 2.2 2.9 2.3

200 8 45 4.2 5.7 4.1

250 10 50 5.9 7.8 5.7

300 12 60 10.5 13.3 9.5

350 14 65 14.1 16.9 13.4

400 16 70 20 24 18.8

450 18 70 36 45 37

500 20 70 44 54 46

600 24 85 65 82 69

700 28 85 91 118 88

750 30 90 110 135 107

800 32 95 135 158 126900 36 100 175 206  1631000 40 140 295 258 281

Note: Other drillings are available. Please consult NOV FGS. 

Blind flanges

Nominal Laying Overall Outside Average

Pipe Length Length Diameter Weight

Size (LL) (OL) (OD)[mm] [inch] [mm] [mm] [mm] [kg]

50 2 70 170 70 0.4

80 3 70 170 100 0.7

100 4 70 170 124 0.9

150 6 70 170 180 1.5

200 8 70 230 230 2.5

250 10 70 290 286 4.0

300 12 70 350 350 9.8

350 14 70 350 381 10.5

400 16 70 410 430 13.2

450 18 70 410 460 9.0

500 20 70 470 524 21

600 24 70 530 619 24

700 28 70 530 745 31

750 30 70 590 795 34

800 32 70 650 840 32

900 36 70 770 951 50

1000 40 70 710 1065 86

Filament-wound couplings with integral Taper/Taper (2-40 inch) socket ends foradhesive bonding.

Couplings

Page 19: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 19/28

 19

Nipples Filament-wound nipples with integral Taper/Taper (2-40 inch) spigot ends for adhesive

bonding.

Nominal Laying Gap Average

Pipe Length * Weight

Size (LL)

[mm] [inch] [mm] [mm] [kg]

50 2 125 25 0.1

80 3 125 25 0.1

100 4 125 25 0.1150 6 125 25 0.3

200 8 190 30 0.7

250 10 250 30 1.3

300 12 320 40 2.4

350 14 320 40 3.0

400 16 380 40 4.6

450 18 400 60 5.6

500 20 460 60 8.3

600 24 520 60 13.3

700 28 520 60 19.7

750 30 580 60 26

800 32 640 60 30900* 36 760 60 39

1000* 40 700 60 54

* Remaining gap after bonding (is distance between the edges of the socket ends);

Support Saddles 

Filament-wound pipe saddles for wear, support and anchor.

Nominal Saddle Saddle Saddle Required Saddle Required

Pipe Angle Thickn. Weight Adhesive Weight Adhesive

Size α ts B=100mm Kits B=150mm Kits

[mm] [inch] [degree] [mm] [kg] [3 and 6 Oz] [kg] [3 and 6 Oz]

50 2 180 14 0.4 ½ - 0.6 1 -

80 3 180 14 0.5 ½ - 0.8 1 -

100 4 180 14 0.7 ½ - 1.1 1 -

150 6 180 14 0.9 1 - 1.4 - 1

200 8 180 14 1.1 1 - 1.7 - 1

250 10 180 14 1.5 - 1 2.3 - 1

300 12 180 14 1.8 - 1 2.7 - 1

350 14 180 14 2 - 1 3.0 - 1

400 16 180 14 2.4 1 1 3.6 - 2450 18 180 16 - - - 3.2 1 1

500 20 180 16 - - - 3.6 1 1

600 24 180 16 - - - 4.3 1 1

700 28 180 16 - - - 5.1 - 2

750 30 180 16 - - - 5.5 - 2

800 32 180 16 - - - 5.8 - 3

900 36 180 16 - - - 6.5 - 4

1000 40 180 16 - - - 7.1 - 5

 Note:• Filament-wound support saddles are intended for protection of pipe at supports and clamps,

as well as for anchoring purposes;• Support and anchor saddles are standard 180°;

• Saddles are supplied in standard lengths of 100 mm and 150 mm;• For special saddle -lengths, -thickness and/or angles consult NOV FGS;• Wear saddles are standard 90°. 90° saddle weights are 50% of value shown.

α

Page 20: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 20/28

20

Adhesive Number of Adhesive Kits per joint with integral Taper/Taper (2-40 inch) socket ends for

adhesive bonding.

Nominal Required Minimum number

Pipe Adhesive Kit of Adhesive Kits

Size Size required per joint

[mm] [inch] [cm3] [Oz] nr.

50 2 89 3 ¹/3

80 3 89 3 ¹/3

100 4 89 3 ½150 6 89 3 ½

200 8 89 3 1

250 10 177 6 1

300 12 177 6 1

350 14 177 6 2

400 16 177 6 2

450 18 177 6 2

500 20 177 6 3

600 24 177 6 3

700 28 177 6 4

750 30 177 6 5

800 32 177 6 6

900 36 177 6 6-7

1000 40 177 6 5-7

Note:•  Adhesive Kits should never be split. If remainder is not used for other joints made at the

same time, the surplus must be discarded;• Required adhesive for saddles is shown in the dimension table of the respective saddles;• For type of adhesive to be used, please refer to the Bondstrand® Corrosion Guide;• Saddles and Taper/Taper adhesive bonded joints require different types of adhesive;• Where 6-7, 5-7 etc. is shown, the first figure is valid for Bondstrand Series 3400 pipe joints.

The second figure is valid for Bondstrand series 2400 pipe joints and fitting joints.

Page 21: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 21/28

 21

Filament-wound 90° elbows with integral Key-Lock ( 4-24 inch) or fabricated Key-Lock

(2-3 Inch) socket ends.

Nominal Laying Overall Average

Pipe Size Length (LL) Length (OL) Weight

[mm] [inch] [mm] [mm] [kg]

50 2 298 318 4.6

80 3 337 357 6.3

100 4 145 165 4.3

150 6 176 203 9.8

200 8 332 369 22.6

250 10 391 431 36.6

300 12 467 513 39.7

350 14 543 592 77.3

400 16 607 721 90.0

450 18 566 660 113.0

500 20 620 719 142.6

600 24 713 801 172.9

Elbows 90°

Key-Lockdimensions

Dimensions for Key-Lock (2-24 inch) mechanical joints.

 

Nominal Number Joint Key to Key to Key Key* O-ring**

Pipe of diameter edge edge distance dimensions dimensions

Size keys socket ends spigot end (2keys)

  OD D N Z

[mm] [inch] [mm] [mm] [mm] [mm] [diaxLGTH] [corexdia]

50 2 1 74.1 20 45 - 6x305 7x59.7

80 3 1 103.0 20 45 - 6x400 7x88.3

100 4 1 128.9 20 45 - 6x483 7x113.7150 6 1 183.3 27 56 - 8x660 10x161.3

200 8 1 234.6 36.5 68.5 - 10x840 10x208.9

250 10 1 290.5 39.5 72 - 12x1090 10x266.1

300 12 1 345.4 46 85 - 15x1270 12.5x316.9

350 14 1 385.5 49 87.5 - 15x1360 12.5x342.3

400 16 2 433.5 51 90.5 63.5 18x1585 12.5x393.1

450 18 2 481.6 46 94 48 15x1570 15x445

500 20 2 529.8 49 97 50.5 15x1930 15x490

600 24 2 626.3 43 94 44.5 15x2240 18x580

* Key material is nylon

** O-rings are available in NBR or EPDM. For other O-ring material contact NOV FGS

1-key with adapters and couplings

1-key 

2-key 

Page 22: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 22/28

22

Equal Tees Filament-wound equal Tee with integral Key-Lock ( 4-24 inch) or fabricated Key-Lock

(2-3 Inch) socket ends.

 

Nominal Laying Overall Laying Overall AveragePipe Length Length Length Length Weight

Size total run total run branch branch

(LL1) (OL1) (LL2) (OL2)

[mm] [inch] [mm] [mm] [mm] [mm] [kg]

50 2 570 610 285 305 6.9

80 3 614 654 307 327 10.6

100 4 290 330 145 165 3.9

150 6 372 426 186 213 11.1

200 8 454 527 227 264 20

250 10 524 603 262 302 30

300 12 606 698 303 349 44

350 14 722 820 361 410 58

400 16 762 991 381 496 95

450 18 866 1054 433 527 148

500 20 932 1130 466 565 180

600 24 1096 1270 548 635 218

Elbows 45° Filament-wound 45° elbows with integral Key-Lock (2-24 inch) or fabricated Key-Lock

(2-3 Inch) socket ends.

 

Nominal Laying Overall Average

Pipe Length Length Weight

Size (LL) (OL)

[mm] [inch] [mm] [mm] [kg]

50 2 256 276 4.4

80 3 272 292 6.0

100 4 82 102 2.5150 6 106 133 6.9

200 8 209 246 17.6

250 10 241 281 22

300 12 285 331 37

350 14 333 382 48

400 16 368 483 64

450 18 300 394 78

500 20 319 419 97

600 24 357 445 115

1-key with adapters and couplings

1-key with adapters and couplings

1-key 

2-key 

1-key 

2-key 

Page 23: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 23/28

 23

Reducing Tees

2x1-Key 

2x2-Key 

Filament-wound standard reducing tees with integral Key-Lock (6-24 inch) socket ends.

Nominal Laying Overall Laying Overall Average

Pipe Length Length Length Length Weight

Size (LL1) (OL1) (LL2) (OL2)

(runxrunxbranch) half run half run branch

[mm] [inch] [mm] [mm] [mm] [mm] [kg]

150x150x100 6x6x4 186 213 172 192 9.8

200x200x100 8x8x4 227 264 198 218 19.3

200x200x150 8x8x6 227 264 212 239 20250x250x100 10x10x4 262 302 226 246 24

250x250x150 10x10x6 262 302 248 267 35

250x250x200 10x10x8 262 302 256 293 37

300x300x100 12x12x4 303 349 258 278 39

300x300x150 12x12x6 303 349 268 295 39

300x300x200 12x12x8 303 349 283 320 41

300x300x250 12x12x10 303 349 290 330 43

350x350x150 14x14x6 361 410 288 315 55

350x350x200 14x14x8 361 410 303 340 57

350x350x250 14x14x10 361 410 310 350 60

350x350x300 14x14x12 361 410 323 369 60

*400x400x150 *16x16x6 380 494 312 339 95*400x400x200 *16x16x8 380 494 326 363 97

*400x400x250 *16x16x10 380 494 333 373 99

*400x400x300 *16x16x12 380 494 348 394 102

*400x400x350 *16x16x14 380 494 385 434 109

*450x450x200 *18x18x8 433 527 352 389 126

*450x450x250 *18x18x10 433 527 359 399 129

*450x450x300 *18x18x12 433 527 372 418 131

*450x450x350 *18x18x14 433 527 409 458 137

*500x500x250 *20x20x10 466 565 383 423 158

*500x500x300 *20x20x12 466 565 396 442 167

*500x500x350 *20x20x14 466 565 433 482 173

*600x600x350 *24x24x14 548 635 482 531 236

600x600x400 24x24x16 548 635 487 602 247

600x600x450 24x24x18 548 635 554 648 259

600x600x500 24x24x20 548 635 565 665 267

* Run is 2-key, branch is 1 key

 

1x1-Key 

Page 24: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 24/28

24

Flanges

Couplings

Filament-wound flanges with fabricated Key-Lock (2-24 inch) spigot end.

Nominal Laying Overall Flange Averagepipe Length Length Thickness Weight*Size (LL) (OL) (D)[mm] [inch] [mm] [mm] [mm] [kg]50 2 116 161 55 1.880 3 116 161 55 2.7100 4 118 163 55 3.6150 6 126 182 55 4.7

200 8 164 232 86 10.3250 10 194 266 116 17.0300 12 232 317 116 25350 14 243 330 116 31400 16 336 426 146 46450 18 331 425 146 53500 20 361 458 176 72600 24 372 466 206 104

* The above weights are based on CL150 Flange

Note:

• Other drillings may be possible. Please consult NOV FGS;

• Full-face elastomeric gaskets may be used suitable for the service pressure, service

temperature and fluid. Shore A durometer hardness of 60 ±5 is recommended (3 mm thick).

Compressed fibre gaskets (3 mm thick), compatible with pressure, temperature and medium

may also be used. Mechanical properties should be in accordance with DIN 3754 (IT 400)

or equal;

• For maximum bolt torque refer to the appropriate Bondstrand literature;

•  A torque-wrench must be used, since excessive torque may result in flange damage.

Filament-wound couplings with integral Key-Lock (2-24 inch) socket ends.

Nominal Laying Overall Outside Average

pipe Length Length Diameter WeightSize (LL) (OL) (OD)

[mm] [inch] [mm] [mm] [mm] [kg]

50 2 100 140 98 0.8

80 3 100 140 127 1.0

100 4 100 140 152 2.2

150 6 127 181 226 4.3

200 8 152 225 275 6.6

250 10 163 242 337 9.6

300 12 186 278 388 11.6

350 14 191 289 435 15.8

400 16 197 426 505 38

450 18 204 392 534 27500 20 210 409 584 32

600 24 200 375 673 29

1-Key 

2-Key 

1-Key 

2-Key 

      O      D

      O      D

Page 25: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 25/28

 25

Nipples Filament-wound nipples with integral Key-Lock (2-24 inch) spigot end.

Nominal Laying Overall Average

pipe Length Length Weight

Size (LL) (OL)

[mm] [inch] [mm] [mm] [kg]

50 2 70 160 0.5

80 3 70 160 0.8

100 4 70 160 1.1

150 6 88 200 2.0200 8 103 240 3.4

250 10 111 255 4.9

300 12 125 295 7.6

350 14 130 305 11.7

400 16 259 440 18.3

450 18 222 410 23

500 20 236 430 26

600 24 212 400 28

1-Key 

2-Key 

Page 26: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 26/28

26

Adapter KLMxTF

Adapter KLMxTM

Filament-wound adapter with integral Key-Lock (2-24 inch) spigot end by integralTaper/Taper socket end for adhesive bonding.

Nominal Laying Overall Average

pipe Length Length Weight

Size (LL) (OL)

[mm] [inch] [mm] [mm] [kg]

50 2 5 100 0.3

80 3 5 100 0.5

100 4 5 100 0.7150 6 4 110 1.0

200 8 1.5 150 1.9

250 10 3 185 2.7

300 12 5 230 4.0

350 14 17.5 245 6.4

400 16 79.5 340 8.2

450 18 61 325 11.5

500 20 83 380 13.9

600 24 76 400 16.9

Filament-wound adapter with integral Key-Lock (2-24 inch) spigot end by integralTaper/Taper spigot end for adhesive bonding.

Nominal Laying Overall Average

pipe Length Length Weight

Size (LL) (OL)

[mm] [inch] [mm] [mm] [kg]50 2 115 160 0.3

80 3 116 161 0.5

100 4 117 162 0.7

150 6 125 181 1.0

200 8 162 231 1.9

250 10 193 265 2.7

300 12 231 316 4.0

350 14 240 327 6.4

400 16 334 424 8.2

450 18 321 415 11.5

500 20 355 452 13.9

600 24 366 460 16.9

1-Key 

2-Key 

1-Key 

2-Key 

Page 27: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 27/28

 27

Engineering design &installation

Consult the following literature for recommendations about design, installation and use

of Bondstrand pipe, fittings and flanges:

 Assembly Instructions for Key-Lock adhesive-bonded joints FP 161

 Assembly Instructions for Taper/Taper adhesive-bonded joints FP 1043

 Assembly Instructions for Bondstrand fiberglass flanges FP 196

Bondstrand Corrosion Guide for fiberglass pipe and tubing FP 132

Bondstrand Pipe Shaver Overview FP 599

Please consult NOV FIber Glass Systems for the latest version of the above mentionedliterature.

Note: Elbows with non-standard angles, non-standard drilled flanges, multi branch tees

and special spools are available on request, please consult NOV FIber Glass Systems.

Bondstrand pipe systems are designed for hydrostatic testing with water at 150% of

rated pressure.

The maximum allowable surge pressure is 150% of rated pressure.

1 psi = 6895 Pa = 0.07031 kg/cm2

1 bar = 105Pa = 14.5 psi = 1.02 kg/cm2

1 MPa = 1 N/mm2  = 145 psi = 10.2 kg/cm2 

1 inch = 25.4 mm

1 Btu.in/ft2h°F = 0.1442 W/mK 

°C = 5/9 (°F-32)

 

Field testing

Surge pressure

Conversions

Specials

Page 28: BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

8/10/2019 BS 2000 2000G 2416 3416 GRE Pipe Systems for Industrial and Oilfield Services

http://slidepdf.com/reader/full/bs-2000-2000g-2416-3416-gre-pipe-systems-for-industrial-and-oilfield-services 28/28

 North America  South America   Europe   Asia Pacific   Middle East 2425 SW 36th Street Avenida Fernando Simoes P.O. Box 6, 4190 CA No. 7A, Tuas Avenue 3 P.O. Box 17324

San Antonio, TX 78237 USA Recife, Brazil 51020-390 Geldermalsen, The Netherlands Jurong, Singapore 639407 Dubai, UAE

Phone: +1 210 434 5043 Phone: +55 31 3326 6900 Phone: +31 345 587 587 Phone: +65 6861 6118 Phone: +971 4881 3566

National Oilwell Varco has produced this brochure for general information only, and itis not intended for design purposes. Although every effort has been made to maintain

the accuracy and reliability of its contents, National Oilwell Varco in no way assumesresponsibility for liability for any loss, damage or injury resulting from the use of information

and data herein nor is any warranty expressed or implied. Always cross-reference thebulletin date with the most current version listed at the website noted in this literature.

www fgspipe com fgspipe@nov com