Amcorp Mall
1. Main commercial areas
2. Two office towers
3. Amcorp Mall Service Suites
![Page 2: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/2.jpg)
MECHANICALAND
AIR-CONDITIONING
![Page 3: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/3.jpg)
VENTILATION
• Ventilation is a process that replacing air in an enclosed space to control the temperature. “A proportion of air within the enclosed space should be continuously withdrawn and replaced by fresh air.” (Greeno, R.,1997, Building Services, technology and design)
![Page 4: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/4.jpg)
CENTRALIZED SYSTEM
• Relatively small building/mall• requires lower service cost and easier for monitoring • cost lesser by 10% -20% compared to individual system • working hour 10am-10pm
![Page 5: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/5.jpg)
FIGURE1.0.1 Control panel for chiller
FIGURE 1.0.2 Condenser pump
![Page 6: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/6.jpg)
DIFFUSER
• The purpose is to discharge chilled/fresh air into space/room
• Ducting system• Different diffuser serve to direct air to different direction• Few type of diffuser were observed
![Page 7: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/7.jpg)
FIGURE 1.0.3 Cone diffuser
FIGURE 1.0.4 Multi-Direction
FIGURE 1.0.5 Linear diffuser
![Page 8: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/8.jpg)
FIGURE 1.0.6 Side-wall inlet
- Enclosed space staircase- No false ceiling
![Page 9: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/9.jpg)
CARPARK VENTILATION SYSTEM
• Mechanical ventilation• Input and extraction of air by air vents and the ducting
system• Vehicles will emit harmful gases pollutant, carbon
monoxide, nitrous oxides, fumes from vehicle fluids, oil and other fuels.
• Cause fire outbreak
![Page 10: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/10.jpg)
FIGURE 1.0.7 VentsFIGURE 1.0.8 Vents
![Page 11: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/11.jpg)
SINGLE ZONE CONSTANT VOLUME• Simplest system • Most suitable (operation hours)• Has an AHU • Temperature kept constant by the thermostat setting on
the cooling load of AHU.
![Page 12: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/12.jpg)
Fire protection system
Active fire protection method• Requires activation. Can be
manual or automatic activation.
• Examples: Fire alarms, detectors, wet & dry risers, hose reels, sprinkler system.
Passive fire protection method
• Integral component of the structural fire protection and fire safety in a building.
• Examples: Fire door, fire-resistant walls, floors.
![Page 13: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/13.jpg)
ACTIVE FIRE PROTECTION METHOD
![Page 14: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/14.jpg)
Fire extinguisher
• To put out small scale of fire to prevent escalation into full scale fire.
• Amcorp Mall uses ABC dry powder fire extinguishers.
• 5 fire extinguishers are placed in every floor in the mall.
• Supplied by Fire Fighter Sdn Bhd.
![Page 15: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/15.jpg)
![Page 16: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/16.jpg)
![Page 17: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/17.jpg)
Fire hydrant
• Consist of a system of pipe-work connected directly to the water supply mains.
• Amcorp Mall uses 2 way fire hydrant.• Distance between 2 hydrants is 70m.• Supplied by Steel Recon Industries (SRI) Sdn
Bhd.• Colour of body: Yellow. (Private system
hydrants connected to public water main.)
![Page 18: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/18.jpg)
2 Way Fire Hydrant (Specification obtained from http://www.sri.com.my/hydrant3.html)
• Body material: Cast Iron to BS 1561• Outlet: Copper alloy BS 1982• Test pressure: 20 bar (300 psi)• Working pressure: 15 bar (217 psi)• Finishing: Yellow
![Page 19: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/19.jpg)
![Page 20: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/20.jpg)
Hose reel
• Intended for occupant to use during early stages of fire.
• Five hose reels are provided in each floor.• Supplied by Unique Fire Industry Sdn Bhd.• Made of PVC• Diameter: 25mm• Length: 30m
![Page 21: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/21.jpg)
![Page 22: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/22.jpg)
Fire sprinkler system
• Designed to detect, control, suppress fire.• Warn the occupants of the occurrence of fire.• Automatic fire suppression system.• Sprinkler head acts as fire detector and
discharge point of water.
![Page 23: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/23.jpg)
![Page 24: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/24.jpg)
Fire alarm
• Provide warning to people through vision and audio appliance when there is an outbreak of fire.
• Can be activated through smoke detectors.• Can also be activated from manual call point.• Each floor has five fire alarms installed.
![Page 25: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/25.jpg)
![Page 26: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/26.jpg)
Fireman’s switch
• Specialized switch disconnector.• Enclosure is made of non-flammable
materials.• Used to disconnect power from high voltage
devices.• Prevent the equipments from exploding.• Painted in red so can be spotted easily.
![Page 27: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/27.jpg)
![Page 28: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/28.jpg)
PASSIVE FIRE PROTECTION METHOD
![Page 29: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/29.jpg)
Fire Escape Staircase & Fire Door
• Fire escape staircase: Used for occupants of the building to escape from the building in the event of fire.
• Fire door: Used to reduce the spread of fire or smoke between compartments.
• The rating of Amcorp Mall’s fire door is 1 hour.
![Page 30: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/30.jpg)
![Page 31: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/31.jpg)
Fireman Lift
• Enable firemen to use in order to rescue people during an event of fire in building.
• Typically a normal passenger or service lift.• Has a toggle switch.• When switch is toggled, the lifts are removed
from normal service.• In fire service mode, the lift door will not
open/close unless the fireman holds the button.
![Page 32: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/32.jpg)
![Page 33: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/33.jpg)
VERTICAL
TRANSPORTATION
![Page 34: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/34.jpg)
ESCALATOR
![Page 35: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/35.jpg)
TWO-WAY TRAFFIC
PARALLEL
![Page 36: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/36.jpg)
ELEVATOR
LIFT
![Page 37: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/37.jpg)
MALL LIFT
![Page 38: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/38.jpg)
FIRE LIFT
![Page 39: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/39.jpg)
SERVICE LIFT
![Page 40: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/40.jpg)
LIFT PERFORMANCE
BAD VENTILATION
FAST SPEED OF LIFT DOOR
CLOSINGCAPACITY
24 PERSONS
NO HAND-
RAILING
![Page 41: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/41.jpg)
DISPLAY BUTTONS
![Page 42: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/42.jpg)
INTERNAL VIEW
INDICATORCONTROL
PANEL
![Page 43: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/43.jpg)
SOMETHING SPECIAL
![Page 44: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/44.jpg)
LIFT ARRANGEMENT
2 CAR LIFT 3 CAR LIFT
![Page 45: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/45.jpg)
LANDING DOORS
TWO SPEED CENTRE OPENING
SINGLE SPEED
CENTRE OPENING
![Page 46: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/46.jpg)
Electrical System
Generated from the power plant
Travels through a distribution grid
Supplies electrical power to the building
![Page 47: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/47.jpg)
Service Entrance
Supplies electrical power to the building
Grounding system current to flow into the
building
Fault protection and dissipating
induced voltages
![Page 48: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/48.jpg)
Electrical Room Stores electrical
equipment
Power distribution equipment
Electrical safety sign
to alert of hazards.
![Page 49: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/49.jpg)
Main Switch BoardService
protection device and
supply
Distributes the large incoming power supply
Providesprotection
![Page 50: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/50.jpg)
Miniature Circuit Breaker (MCCB)
Automatically operated
electrical switch
Protect an electrical circuit
from damage
To detect fault condition and
interrupt
![Page 51: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/51.jpg)
Cable management
Support insulated
electric cables
Cable Tray System
![Page 52: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/52.jpg)
Problems of vertical transportation
• Escalatora) No brush detectorb) Malfunction of the escalator
![Page 53: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/53.jpg)
• Lift
Abandoned Lifts
![Page 54: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/54.jpg)
No CCTV system in the lift
No Handrail in it
No door sensor
![Page 55: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/55.jpg)
Some certain floors cannot access
![Page 56: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/56.jpg)
Recommendation to Escalator Install brush detector guard Install Infrared motion
![Page 57: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/57.jpg)
Recommendations for Lift
• Improving good service of maintenance• Installing of handrail
![Page 58: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/58.jpg)
Installing of CCTV
• Using laser optic transmitter and receiver• Associated with the observation DVR
utilizing cajole link• If the light go deem, the system still can
operate
![Page 59: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/59.jpg)
Advantages
• Saves high installation costs, quick and easy installation, semi-permanent life span, real time transmission, high quality (DVD quality) video transmission and high reliability.
• Ensure security protection
![Page 60: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/60.jpg)
Installing Thru-beam sensor
• These sensors can recognize objects free of shading, reflectivity and are not influenced by second surface reflections.
• When interrupting the light beam this will cause a change in the output status of the receiver. Through-beam sensors offer the longest sensing range of up to 100 meters.
![Page 61: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/61.jpg)
• Provides quick snap-in installation and is very affordable
• Easily fit within a door frame or extruded metal railing.
• Secure detection for automatic door and gate systems, monitoring function in turnstiles and closing edge monitoring in elevators.
![Page 62: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/62.jpg)
1.Number of openingsAmcorp mall does not seem to have sufficientnumber of openings.
2.Harmful pollutantSince the car park is not incorporated withsufficient ventilation, there is possibility thatharmful pollutant such as carbon monoxide,nitrous oxides, fumes from vehicle fluids, oiland other fuels exist in large scale.
4.2 Ventilation4.2.1 Problems of ventilation system
![Page 63: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/63.jpg)
3. Growth of mould and mildewDestroy the general aesthetic of the building.
4.RustAffect plumbing or pipe work that may run through various rooms in the building. In theworst case, it may also cause venting straps tomalfunction.
![Page 64: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/64.jpg)
5. Poor air flowPoor air flow is linked to respiratory diseasessuch as asthma, and can also facilitate thespread of diseases.
6. Unpleasant odourThe buildup of damp and humidity in abuilding create an unpleasant odor. Thisfragrance can be particularly difficult to get rid of,unless the air quality in the building is improved.
![Page 65: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/65.jpg)
7. High expensesAll the problems above contribute to highexpenses to maintain the building at its finest.
ConclusionWhen you consider all of the negative healthimpacts and financial expenses associated withpoor ventilation, and then naturally, it is morecost-effective to ensure a building is wellventilated.
![Page 66: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/66.jpg)
1. Replace conventional ventilation system with impulse ventilation.
• Impulse ventilation is a system intended for the ventilation of enclosed and basement car parks without the use of ducting within the body of the car park
4.2.2 Recommendation for ventilation system
![Page 67: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/67.jpg)
1.Cost savings on building and mechanical equipments investment.
• Building height can be reduced due to the flexibility of the installation of the fans. Thus total air flow will decrease which help to reduce the power of the main exhaust and makeup air fans. Besides smaller mechanical fans, the gent set sizes will become smaller also.
Advantages of Impulse Ventilation
![Page 68: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/68.jpg)
2. Energy saving.
• Depending on the pollution level, either more impulse fans are activated to increase air mixing thereby reducing the concentration of CO gases, or the airflow rate is increased to extract the polluted air more quickly. Lower airflow rates can also reduce the amount of attenuation needed, since the rate of extract overnight can be reduced when there is very little, if any, traffic movement.
![Page 69: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/69.jpg)
3. Higher efficiency.
• Impulse ventilation incorporates a fully addressable fire detection system. This provides early detection of a fire and its location. Enabling the fire service to determine the most suitable route to approach the fire. Then, the impulse ventilation system will switch to smoke extract mode, thus increasing the rate of ventilation through the main extract fans and activating only the impulse fans necessary to control the flow of smoke.
![Page 70: Bs ii presentation finale](https://reader038.vdocuments.net/reader038/viewer/2022103010/587c3d111a28ab5a1d8b56d7/html5/thumbnails/70.jpg)
4.Space and completion period. • The smaller sized main exhaust and make up
air fans allow the use of smaller fan rooms or eliminate the need altogether. With the elimination of ductworks, the duration of ventilation work will be reduced.