building solutions for life - ecospecifier · plasterboard is also used to make prefabricated...
TRANSCRIPT
BuilDing SolutionS For liFE
PARTITIONING SOLUTIONS
Par
tition
ing
Solu
tion
S
01 LafargePlasterboard
02 LafargeFixedPartition
03 LafargeFinesseRemountablePartition
04 LafargeCompounds
CONTENTS
04
12
36
48
The quesTion of qualiTy versus speed has always been a conTenTious one in The inTerior design. economics and demand require buildings To go up quickly and affordably, which could compromise qualiTy.
LAFA
RG
EPLA
STERBO
AR
D
LAFARGE PARTITION SOLUTIONS 4
LafargE gYPSUM PLaSTErbOard
Lafarge Gypsum Plasterboard consists of an aerated gypsumcore encased in and firmly bonded on both sides with specialplasterboard liner, rendering a smooth yet highly functionalsurface.Specialcharacteristicsofgypsumprovidetheoutstandingadvantagesoverotherflatsheetmaterials.
Theboardisfabricatedbyamodernautomaticprocesswiththesupervisionofhighlyexperiencedengineersandchemists.
The question of quality versus speed has always been acontentious one in interior design. Economics and demandrequire buildings to goupquickly andaffordably,which couldcompromisequality.
Lafarge Gypsum Plasterboard: Designed for internal walls,ceilings and partitions in residential and commercial buildings,isquickandeasytoinstall,whilestillbeingdurable,recyclable,aesthetic and of superior quality without the necessary dryingtimeforalternatewettradesolutions.
Want to knoW What separates a great interior from the average?
high quality, eCospeCifier listeD,lafarge gypsum plasterboarD
LAFARGEPARTITIONSOLUTIONS 5
laFa
rg
E PlaStEr
Boa
rD
Pr
oD
uCt r
an
gE
There are three types of Lafarge Plasterboard available from Lafarge Gypsum: Standard, Fire Resistant and Moisture Resistant.
Lafarge Standard Plasterboards are exceptionally versatile andlightweight. They can be used for domestic and commercial ceilingapplications as well as walling/partitioning applications. LafargePlasterboard is also used to make prefabricated bulkheads, curvedceilings (barrel) and radiused walls among other innovativeapplications.LafargePlasterboardisadurable,versatileproductthatiscleanandrecyclable.
WhencombinedwithourLafargeCeilingGridsuspensionsystemorourSteelBrandering,anextremelyflatceilingsurfaceisachieved.
LafargeExtraFireResistantPlasterboardisrecommendedfordrywallinginkitchensandareaswhereadditionalfireresistanceisrequired.
AllofourLafargePlasterboardsaretestedatSABSPretoriaFireTestingfacilitytoSANS10177part2-2005.Wallscanbedesignedtosuityourfireratingrequirementsuptoa2hourfirerating.
LafargeMoistureResistantPlasterboardisrecommendedforuseinallwetareassuchasbathroomshowers,aswellas locationswithhighhumiditylevels.LafargeMoistureResistantPlasterboardissupportedwith special additives in the core, to retard the absorption rate ofmoisture, ensuring that the Lafarge Plasterboard maintains its highperformancelevelovertime.
Our boards have two different edges:1. Square Edge (S.E.) for coverstrip jointing; visible butt jointed
panelingwithclampfixingandfeesuspension.
2. Tapered Edge (T.E.) for smooth and seamless jointing; jointlesswallandceilingpaneling.
Width
Ceilings
Partitions
Partitions
2 400; 2 700; 3 000; 3 6001 2009
12
15 14.0
9.50
7.30
1 200
1 200 2 400; 2 700; 3 000; 3 600
2 400; 2 700; 3 000; 3 300; 3 600
Weight kg/m2 (Approx) UseLength (mm)Thickness (mm)
TaperedEdge
2 400; 2 700; 3 000; 3 300; 3 600
Length (mm) Weight kg/m2 (Approx) UseThickness (mm) Width
1 200900 5.50 Ceilings
Partitions9.50
9
6.4
12 1 195 2 400; 2 700; 3 000
Lafarge Plasterboard Dimensions
S/E can be manufactured to order with minimum quantities
SquareEdge
LAFARGEPARTITIONSOLUTIONS 6
CHaraCTErISTIC Of LafargE PLaSTErbOard
Lafargegoes togreat lengths toensure that theend-user receivesqualityproducts.Testing at the SouthAfrican Bureau of Standards is an ongoing process and everyeffortismadetoensuretestingisasclosetositeconditionsaspossible.
Some of the most important tests are as follows:• FireresistantSANS10177part2–2005 Hereawallmeasuring2.7by2.7misplacedintheopeningofafurnace,andfired
uptosimulateactualfireconditions.Thewallissubjectedtothisfireandheatforalimiteddurationoftimeasperourrequest-i.e.30minutes/60minutesor120minutes,dependingonthesystembeingtested.
The Lafarge wall must be able to withstand 3 important criteria, namely FireStability (loadbearingcapacity),Fire Integrity (tightnessagainstflame,gasandotherleakages)andFireInsulation(180degreesplusambientisthecut-offlimit),beforeafireratingcanbeissuedtothesystem.
Other Tests:• Gridlockdeflection-SANS7228/158EMTO1• SagTestBS8290• SagTestTDCMO3-TDC-022D• SANS/ASTM367-89• 7228/013/MT01/REVA• 5544/158C/MT01• 7228/158C/MT01• 7228/112A/MT01• PullTestLafargeGypsum-TDCM02-TDC-023-D
Storage and Handling of Lafarge Plasterboard1. LafargePlasterboard shouldbe stackedflat inadryandsmootharea toavoid
grounddampness.2. Usewoodenbearersassupports.3. 6,4mmboard =50/stack 9mmboard =80/stack 12mm standard =2,7m=60 =3,3m=60 =3,6m=60 15mmstandard =40 15mmboard(FC+MR) =404. Nomorethan5stacksshouldbepiledoveroneanother.Thebearersofeachstack
mustbealigned.5. TheLafargePlasterboardsshouldbekeptindoors.Ifoutsidestorageistemporarily
required,covertheLafargePlasterboardswithplasticorwaterproofcanvas.6. LafargePlasterboardshouldbecarriedonitsedgesinanuprightpositionbytwo
people,ratherthanflat.1to2LafargePlasterboardscanbecarriedatatime.
LAFARGEPARTITIONSOLUTIONS 7
laFa
rg
E PlaStEr
Boa
rD
Pa
rtitio
nS
Partition Installation Using a Lafarge Ridgeback Steel Stud and Track1. Installthegalvanisedsteelstudbylayingfloortrackshorizontally
onfloorandceilingandfixinplace.2. Insert studs vertically in tracks and leave space between each stud at 400 or 600mm intervals. The studs are held in place byfriction.3. Attach12mmtapered-edgeLafargePlasterboard steel studsby
drivingthe25mmDrywallscrewintoit.Thespacebetweeneachscrewshouldnotexceed220mm.
4. ConcealthejointcornerandscrewdimplewithLafargeJointingPlaster.Allowforsettingtime,thensmooth.
Installation of Lafarge Firecheck PlasterboardFor use in office partitioning, residential internal walling, shoppingcentres,hotels,hospitals,schoolsandthelike,a2hourfireratingorasafe/securewallisrequired.
Application Details:• Set63.5mmstudsspacedat600mmintervalsinto65mmtrackat
floorandceiling.• Applyabaselayerof12.5mmLafargeExtraFire
ResistantPlasterboardverticallytoeachsideusing25mmDrywallScrewsspacedat220mmintervals.
• Fix a layer of 0.5mm galvanised steel sheeting using 25mmdrywallscrews.
• Applythefacelayerof12.5mmLafargeExtraFireResistantPlasterboardverticallytoeachsideusing41mmDrywallScrewsspacedat220mmintervals.
• UseFibatapeandLafargeJointingPlasteroverthejoints.• Alljointsaretobestaggered.• Acoustic enhancement requires sealing between track, floor,
ceilingandanyotherabutmentjoints.
0.5mm Galvanised Steel Sheet
63.5mm Stud
12.5mm Lafarge Firecheck Plasterboard
12.5mm Lafarge Firecheck Plasterboard
65mm Track
Acoustic Sealant/Gasket
LAFARGEPARTITIONSOLUTIONS 8
LafargE PLaSTErbOard INSTaLLaTION TIPS
PARTITION:1. ThelengthofscrewforfixingLafargePlasterboardtometalstudisequaltothe
thicknessofLafargePlasterboardplus10mm.2. Ifthelengthofthepartitionismorethan15m,atevery15mintervalanexpansion
jointmustbeusedinordertopreventcracking.3. Always leave about 10mm space from the floor to prevent dampness from
creepingupthePlasterboard.4. Inhighhumidityareas,usetheLafargeMoistureCheckPlasterboard.
CURVED SURFACE INSTALLATION OF PARTITIONSLafargePlasterboardcanbecurvedintomanyformstofitvariousdesiredinteriorwallandceilingdesigns.
Framing Installation:The horizontal steel track can be prepared in 2 ways, using either the internal orexternalarcwebcuts.1. Cutonelegandweboftopandbottomsteelstudat50mmintervalsforthelength
ofthearc.Leaveabout400mmofuncutsteelstudsatendofarc.2. BendtrackseitherasAorBtoformcurveofdesiredradius(90mmmaxarc).3. Attachthesteeltracktostructuralelementsatfloorandceiling.Positionvertical
studs,withopensidefacingthesamedirectionandengagingfloorandsteelstuds.
Lafarge Plasterboard
Spacing between vertical stud depends on the radius of curve
Floor Track
LAFARGEPARTITIONSOLUTIONS 9
LAFA
RG
E PLASTER
BOA
RD
PA
RTITIO
NS
Apply sufficient Lafarge Jointing Plaster over the screw head to achieve a smooth surface. Allow 30 minutes for the plaster to set. Apply the second coat (if required) and leave it for 2 hours. Smooth with sand paper.
EXTERNAL CORNER CONCEALING FOR PARTITIONSA corner bead is used for reinforcing the corner of a LafargePlasterboard partition.1. Cut the corner bead to the same length as the partition
height.2. Attach it to both sides of the corner.3. Fix 25mm Drywall Screws along the corner bead at every
100mm interval on both sides.4. Conceal both sides of the corner bead with Lafarge
Jointing Plaster approximately 3mm thick. Leave for 70 minutes to set.
5. Apply the second coating about 300mm wide from the corner edge.
6. Allow 24 hours after second coating, smooth with 80 grit sandpaper.
CUTTING LAFARGE PLASTERBOARDLafarge Plasterboard has a unique snap-effect which allows for easy cutting of the board and can be cut by using two methods.Using a sharp cutter1. Draw a line on the board.2. Cut the board by first scoring on the face side through the
paper to the core (a straight edge helps).3. The board is then snapped back away from the cut face.4. The back paper can be broken by snapping the board in
the opposite direction, or by scoring with a utility knife.5. Sand all cut edges.
Using a saw1. Draw a line on the board.2. Saw the board by a fine tooth saw.3. Sand all cut edges.
Metal Stud
Optical Insulation
Lafarge Plasterboard
25mm Screw
Corner Bead
Lafarge Jointing Plaster
Lafarge
Lafarge
Lafarge Plasterboard (Ceiling)
Lafarge Plasterboard (Partition)
Snap Lafarge Plasterboard and cut other side of paper
LAFARGE PARTITION SOLUTIONS 10
drYWaLL SCrEW HEad CONCEaLINg
JOINT CONCEALINGThere are three steps to concealing joints:1. CentretheFiba-tapeonthejointandpressitdownwiththescrapertoensurethe
Fiba-tapeadheresfirmly.2. ApplyacoatofLafargeJointingPlasterontotheFiba-tapeusingascrapertoeven
thesurfaceandtoensuretheplasterflowsintotheFiba-tape.Allow70minutes toset.3. Cleanthejointsurfacewiththeedgeofatrowelandapplythesecondcoat.Allow
24hoursfortheplastertodrythoroughly.Smooththejointbysandingtoachieveamonolithicsurface.
DEPTH OF DRYWALL SCREWS
LAFARGEPARTITIONSOLUTIONS 11
laFa
rg
EFix
ED Pa
rtitio
n
Lafarge Drywall is a lightweight non-demountable partition systemwhich has no visible joints on completion. The internal frameworkconsists of standard Ridgeback Stud and Drywall Track profilesmanufactured fromgalvanisedsteel.Taperededgeplasterboardsarescrewfixedtothestudsallowingforplasterjointing.Paintorwallpaperfinishescanthenbeappliedforajointfreewallofsubtlequality.
AttractiveSlimlineGlazingMullionsandtransomscanbecreatedbyclip fixing the required aluminium male section onto its four-leggedfemalepartnerwhichhasalreadybeenfixedintoposition.
DoorFrameKitsaresuppliedpremitredandwithoptionallockcutouts.FullheightDoorFramesclipdirectlyontotheAluminiumFemaleceilingtrim by means of the MaleAluminium Door header. Standard doorframekitshavebothstylesandheadermanufacturedfromfour-leggedFemaleAluminium Door Frame sections. It is recommended that foradditionalstabilitywhenerectingfullheightdoors,theRidgebackStudshouldbeboxedontotheopensideofaFloorTrackpriortofixing(theFemaleDoorFrameSection).
The four-legged Female partition solutions Aluminium Door Frame,GlazingandTerminationSectionsarepositivelyfixedtothegalvanisedsteelRidgebackStudsbymeansofpoprivetsorscrews.ThisensuressturdyframingforthePlasterboardsandstrongsupportfortheclip-onMaleAluminiumsections.
TheAluminiumGlazingBeadwhichcarriesaneatBubbleSealGasket(oroptionalwoolpile)easilyclips intoplaceaftertheglasshasbeenpositioned, leaving an attractive Aluminium shopfront type finish,havingslimandcleanlines.TheBubbleSealGasketwillaccommodateglassthicknessfrom4mmto6mm.(nominalthickness).
Fire rating: Lafarge Drywall (89mm partition) has a 30 minute firerating as per SABS 0177: Parts-2005. For further details as well asinformation on 60 minutes plus fire ratings please consult with ourtechnicalstaff.
AllLafargeAluminiumsectionsmaybePowderCoatedorAnodisedtocomplementthedecoratedfinishoftheboards.AluminiumSkirtingorrecessedbasecanbesimilarlytreatedtomatchorcontrastasrequired.
LAFARGEPARTITIONSOLUTIONS 12
COMPONENTS
CONNECTING LAFARGE PARTITION SOLUTIONS
Lafarge Aluminium FramingTheLafargeDrywallSystemconsistsofMaleandFemaleAluminiumextrusions.• FemaleSectionssupportandpositiontheLafargePlasterboardasinconventional
drywalling.• MaleSectionsareclipfixedtotheFemaleSectionstoformGlazingMullionsand
Transoms,DoorframetoGlazingdetailsandtofacilitatefullheightGlazingandfull height doors. Bubble Seal Gasket (which is used for both Door frame andGlazingSections)istobeinsertedbeforeconstructingtheframes.
MALE ALUMINIUM SECTIONSFEMALE ALUMINIUM SECTIONS
LAFARGEPARTITIONSOLUTIONS 13
laFa
rg
EFix
ED Pa
rtitio
n
MALE ALUMINIUM SECTIONSFEMALE ALUMINIUM SECTIONS
LAFARGEPARTITIONSOLUTIONS 14
MALE ALUMINIUM SECTIONSFEMALE ALUMINIUM SECTIONS
aLTErNaTIVE aLUMINIUM
ALTERNATIVE ALUMINIUM HEAD AND BASE SETS
Termination Die 6056 for 76mm Die 6161 for 89mm
Termination- head channel- wall channelDie 6060 for 76mm (12mm board)Die 6160 for 89mm (12mm board)Die 6632 for 89mm (15mm board)
LAFARGEPARTITIONSOLUTIONS 15
laFa
rg
EFix
ED Pa
rtitio
n
ALTERNATIVE ALUMINIUM SECTIONS
ALTERNATIVE ALUMINIUM HEAD AND BASE SETS
LAFARGEPARTITIONSOLUTIONS 16
1. Aluminium Male Termination Section Die 61612. Aluminium 4 Leg Female Double Glazing Section Die 62013. Aluminium Male Door Frame Section Die 61644. Aluminium Male Glazing Section Die 66725. Aluminium Glazing Bead Die 66746. Ridgeback Stud (64mm)7. 4-6mm Glass8. Lafarge Plasterboard9. Bubble Seal Gasket10. Blinds11. Blinds Mechanism Showing Cable12. 40mm Door13. Aluminium Sinkless Hinge14. Pop Rivets
dOUbLE gLaZINg/INTEgraL bLINdS
LAFARGEPARTITIONSOLUTIONS 17
laFa
rg
EFix
ED Pa
rtitio
n
ALUMINIUM DOORS
LAFARGEPARTITIONSOLUTIONS 18
aLTErNaTIVE aLUMINIUM
ALUMINIUM DOORS
LAFARGEPARTITIONSOLUTIONS 19
laFa
rg
EFix
ED Pa
rtitio
n
CONSTRUCTION DETAILS
1 Lafarge Ridgeback Stud2 Lafarge Plasterboard (tapered edge)3 Drywall Screws 4 Skimmed joint
1 Aluminium 4 Leg Female Termination Die 6060/61602 Lafarge Plasterboard3 Drywall Screws 4 Aluminium Termination (alternative) Ceiling and Wall Channel Die 6204/62055 Drywall Track6 Fixing (mechanical/velcro/ grip clip)
1 Aluminium Ribbed Skirting Die 61442 Lafarge Plasterboard3 Lafarge Ridgeback Stud4 Drywall Track5 Skirting Screws
1 Aluminium Recessed Head Die 6165/61662 Lafarge Ridgeback Stud3 Lafarge Plasterboard4 Ceiling Tile5 Fixing (mechanical/velcro/grip clip)6 Drywall Screws
1 Aluminium 4 Leg Female Glazing Die 6668/66792 Aluminium Glazing Bead3 Lafarge Ridgeback Stud4 Lafarge Plasterboard5 4-6mm Glass6 Drywall Screws7 Bubble Seal Gasket
1 Aluminium 4 Leg Female Glazing Die 6059/61592 Lafarge Ridgeback Stud Die 66743 Lafarge Plasterboard4 Door (40mm)5 Drywall Screws6 Bubble Seal Gasket7 Drywall Track (optional for additional stability for full height/solid doors and swing doors).8 Aluminium Sinkless Hinge
Drywall Joint1
LAFARGEPARTITIONSOLUTIONS 20
LafargE fIxEd ParTITIONCONSTRUCTION DETAILS
Door Frame/Glazing Mullion1 Aluminium 4 Leg Female Doorframe2 Lafarge Ridgeback Stud3 Aluminium Male Glazing Section Die 6667/66784 Aluminium Glazing Bead Die 66745 4 - 6 mm Glass6 Door (40 mm)7 Pop Rivets8 Bubble Seal Gasket
Glazing Mullion or Transom1 Aluminium 4 Leg Female Section Die 6668/66792 Lafarge Ridgeback Stud3 Aluminium Male Glazing Section Die 6667/66784 Aluminium Glazing Bead Die 6674 with Bubble Seal Gasket5 4 - 6 mm Glass6 Pop Rivets7 Bubble Seal Gasket
Door frame with Corner and Glazing1 Aluminium 4 Leg Female Door frame Die 6059/61592 Aluminium 4 Leg Female Section Die 6668/66793 Aluminium Glazing Bead Die 60364 Lafarge Ridgeback Stud5 Lafarge Plasterboard6 Door (40 mm)7 4-6mm Glass8 Drywall Corner Bead9 Dry Wall Screws10 Bubble Seal Gasket11 Skimmed Corner
Standard Corner1 Lafarge Ridgeback Stud2 Drywall Corner Bead3 Lafarge Plasterboard4 Drywall Screws5 Skimmed Corner
Recessed Base(alternative to fig 3)1 Aluminium recessed Base Die 6206/62072 Lafarge Ridgeback Stud3 Lafarge Plasterboard4 Drywall Screws
Dry Lining Detail Utilising Plasterboard Trim1 Plasterboard Trim Die 63042 Lafarge Plasterboard3 Lafarge Ridgeback Stud4 Drywall Track5 40mm Drywall Screws2 5mm Drywall Screws
6
7
8
9
10
11
LAFARGEPARTITIONSOLUTIONS 21
laFa
rg
EFix
ED Pa
rtitio
n
POWER SKIRTING DETAILS
TYPICAL CONSTRUCTION DETAILS
TwosectionsofWALLMOUNTEDPowerSkirtingplacedbacktobacktoachievedoublevolumePowerSkirting.
Cover PlateDie 1829
Power Skirting
Power Skirting
1. Wall Starter/Termination/Ceiling Junction1Aluminium4LegFemaleTerminationDie66322LafargePlasterboard3DrywallScrews4AluminiumTermination(alternative)CeilingandWallChannelDie6204/62055DrywallTrack59mm6Fixing(mechanical/velcro/gridclip)
2. Glazing Mullion1Aluminium4LegFemaleGlazingDie66772AluminiumGlazingBeadDie66353LafargeRidgebackStud58mm4LafargePlasterboard54-6mmGlass6DrywallScrews7BubbleSealGasket
LAFARGEPARTITIONSOLUTIONS 22
TYPICAL CONSTRUCTION DETAILS
FIRE RATING ON SYSTEM AVAILABLE
LafargE fIxEd ParTITION
3. FOR 15MM LAFARGE PLASTERBOARDDoor Frame 1Aluminium4LegFemaleDoorframeDie66332LafargeRidgebackStud3LafargePlasterboard4Door(40mm)5DrywallScrews6BubbleSealGasket7AluminiumSinklessHinge
4. Door Frame (Full Height, Solid and Swing Doors)1Aluminium4LegFemaleDoorFrameDie66332LafargeRidgebackStud58mm3LafargePlasterboard4Door(40mm)5DrywallScrews6BubbleSealGasket7DrywallTrack59mm(optionalstabilityforfullheight/soliddoors/swingdoors)8AluminiumSinklessHinge
Specifications: Lafarge Fixed Partitions: 76mmSupplyand install LafargeFixedPartition fromLafargeGypsum,drywallpartitioningsystemwithanoverallthicknessof76mmcomprisinginternalframingformedof51mmLafarge galvanised steel studs fixed at 600mm centres to Lafarge galvanised steeltrack/aluminiumfemaleheadsectionandLafargegalvanisedsteelfloortrack,wherenecessary,anyadditionalgalvanisedsteelstuddingtoformdooropenings,glazingandotherapertures,anglesandcornersandterminatedends.Theinternalsteelframingistobedressedonbothsideswith12mmthickLafargetaperededgeplasterboardsinsinglelengthstosuitheight,buttjointedandsecuredtoasteelstuddingwith25mmdrywallscrewsatamaximum220mmcentres.JointsaretobetappedandjointedwithLafargeJointingCompoundandpreparedforpaintingorwall-papering.Allexternalaluminiumdoorframes,glasingframes,ceilingandwallchannelsandskirtingaretobeformedofnaturalanodised/colouranodised/powdercoatedtospecificcolour.
Maximum height 3 600mm.InstallationtobeinaccordancewithSABISA(SouthAfricanBuildingInteriorSystemsAssociation)installationguidelines.
Specification: Lafarge Fixed Partition: 89mmSupplyand install LafargeFixedPartition fromLafargeGypsum,drywallpartitioningsystemwithanoverallthicknessof89mmcomprisinginternalframingformedof64mmLafarge galvanised steel studs fixed at 600mm centres to Lafarge galvanised steeltrack/aluminiumfemaleheadsectionandgalvanisedsteelfloortrack,wherenecessary,any additional galvanised steel studding to form door openings, glasing and otherapertures,anglesandcornersandterminatedends.Theinternalsteelframingistobedressedonbothsideswith12mmthickLafargetaperededgeplasterboardsinsinglelengthstosuitheight,buttjointedandsecuredtoasteelstuddingwith25mmdrywallscrewsatamaximum220mmcentres.JointsaretobetappedandjointedwithLafargeJointingCompoundandpreparedforpaintingorwall-papering.Allexternalaluminiumdoorframes,glasingframes,ceilingandwallchannelsandskirtingaretobeformedofnaturalanodised/colouranodised/powdercoatedtospecificcolour.
Maximum height 3 600mm.InstallationtobeinaccordancewithSABISA(SouthAfricanBuildingInteriorSystemsAssociation)installationguidelines.
LAFARGEPARTITIONSOLUTIONS 23
laFa
rg
EFix
ED Pa
rtitio
n
LAFARGE FIXED PARTITION SPECIFICATIONS AND DETAILS
Lafarge Fixed Partition SpecificationLafarge Fixed Partition is a lightweight walling system which hasno visible joints on completion. The internal framework consists ofstandard Lafarge Ridgeback stud and Lafarge Fixed Track profilesmanufacturedfromgalvanisedsteel.
Tapered edge Lafarge Plasterboards are screw fixed to the studsallowing for plaster jointing. Paint or wall paper finishes can thenbeapplied fora joint freewallof subtlequality.Thisensures sturdyframingfortheLafargePlasterboards.
Firerating:LafargeResidential(89mmpartition)hasa30minutefirerating as per SABS 0177: Parts 2005. For further details as well asinformation on 60 minutes plus fire ratings please consult with ourtechnicaldepartment.
ComponentsIntemal FrameworkThe internal framework shall consist of floor and ceiling track withverticalLafargeRidgebackStuds.TheLafargeFloorTrackshallbefirmlyscrewedorshotfixedtothefloor.Thetoptrack(Galvanised),shallbefixedtotheLafargeceilinggridorroofstructure.Whenfixingtoothersolidsurfacesthetoptrackshallbemechanicallyscrewedorshotfixed.
Door FramesAluminiumdoorframestofit76mm/89mmpartitionscanbeused.Forfirerateddrywallpartitions,pre-madefirerateddoorsmustbeused.Custom made pressed steel or timber door frames can be used fornon-standarddrywalls.
PanelsInstallation(SeeFigure1and2)Installation shall commencewith thefixingof the track to thefloorand the ceiling. Studs to be fixed to existing wall as a wall starter.TheLafargeRidgebackStudsaretheninstalledverticallyatmaximum600mm centres.The 12mm -15mm thickness tapered edge LafargePlasterboardsarethenheldinplacebymeansof25mmdrywallscrewswhicharedriventhroughtheLafargePlasterboardandintotheLafargeRidgebackStudsatamaximumspacingof220mmbetweenscrews.
TheLafargePlasterboardsareheldinplaceatthebasebytheskirtingandfixedtothesteelframeworkwith25mmdrywallscrews.WheretheLafargeFixedPartition isbeing installedbeneathaplasteredceiling,LafargeGalvanisedDrywallTrackisfixedtotheceiling.
JointingLafargePlasterboardstaperededgepointstobefinishedwithfiba-tapeandjointingcompound.
Wall FinishesWallsshouldbeprimedwithasuitableprimerandthenpaintedwithacolourtosuit.
DoorsAlldoorsmustcomplywithGeneralSpecificationforFixedPartitions.
General Guide Lines for Partitioning Systems and lightweight walls.Specialattentionshouldbegiven to theglazinganddoordetaiIs toensurethecompliancetothefireregulation,ifrequired.
All Steel
components of
the Lafarge
Partition System are
manufactured by
Lafarge Gypsum Reg
No. 1997/08520
ISO9001 - 2008
LAFARGEPARTITIONSOLUTIONS 24
LafargE fIrE raTEd ParTITION SYSTEMS
LAFARGE GYPSUM DRYWALL LPS 51-0 /1INTERNAL PARTITION SYSTEMNonloadbearingdrywallsystem12mmStandardPlasterboard-onelayereachside
APPLICATION: Commercial
WALL PROPERTIES 51mmstudSoundinsulationreductionindex -36dBThickness -76mmApproximateweight -20kg/m²
MATERIAL USEDA - 51mmDrywallLafargesteelstudB - 52mmDrywallLafargesteeltrackC - 12mmStandardTaperededgePlasterboard - 25mmDrywallScrews - LafargeDrywalljointingsystem - Floorandceilingfinishesasperspecification
APPLICATION DETAIL1. SetLafargesteelstudsspacedat600mmc/cintosteeltrackat floorandceiling.2. Applyasinglelayerof12mmLafargeTaperededgeplasterboardto eachsidesideusing25mmdrywallscrewsspacedat220mmc/c.3. Tapeandjointaccordingtospecification.4. Refertostandardspecification.5. Acousticperformancerequiressealingbetweentrack,floor,ceiling andanyotherabutmentjoints.6. Staggertheplasterboardjointsinthesystem.
600,00
C: Lafarge 12mm Plasterboard
B: Lafarge 52mm steel track
A: Lafarge 51mm steel stud
LAFARGEPARTITIONSOLUTIONS 25
laFa
rg
EFix
ED P a
rtitio
n
LAFARGE GYPSUM DRYWALL LPS 58 -0/1Nonloadbearingdrywallsystem15mmTechnicalFirecheckPlasterboard-onelayereachside
APPLICATION: CommercialandResidential
WALL PROPERTIES58mmstud60MinfireratingSoundinsulationreductionindex -40dBThickness -88mmApproximateweight -23kg/m²
MATERIAL USEDA - 58mmDrywallLafargesteelstudB - 59mmDrywallLafargesteeltrackC - 15mmFirecheckTaperededgePlasterboard - 25mmDrywallScrews - LafargeDrywalljointingsystem - Floorandceilingfinishesasperspecification
APPLICATION DETAIL1. SetLafargesteelstudsspacedat600mmc/c intosteelatfloorandceiling.2. Applyasinglelayerof15mmFirecheckTaperedgeplasterboard toeachsideusing25mmdrywallscrewsspacedat220mmc/c.3. Tapeandjointaccordingtospecification.4. Refertostandardspecification.5. Acousticperformancerequiressealingbetweentrack,floor, ceilingandanyotherabutmentjoints.6. Staggertheplasterboardjointsinthesystem.
C: 15mm Fire Chec
A: 58mm Lafarge steel stud
B: 59mm Lafarge steel track
k board
600,00
A: Lafarge 58mm steel stud
C: Lafarge 15mm Firecheck Board
B: Lafarge 59mm steel track
LAFARGEPARTITIONSOLUTIONS 26
LafargE fIrE raTEd ParTITION SYSTEMS
LAFARGE GYPSUM DRYWALL LPF 64 - 30/130 MIN FIRE RATED INTERNALPARTITION SYSTEMNonloadbearingdrywallsystem12mmStandardPlasterboard-onelayereachside
APPLICATION: CommercialandResidential
WALL PROPERTIES64mmstud30MinfireratingSoundinsulationreductionindex -38dBThickness -89mmApproximateweight -21kg/m²
MATERIAL USEDA - 64mmDrywallLafargesteelstudB - 65mmDrywallLafargesteeltrackC - 12mmStandardTaperededgePlasterboard - 25mmDrywallScrews - LafargeDrywalljointingsystem - Floorandceilingfinishesasperspecification
APPLICATION DETAIL1. SetLafargesteelstudsspacedat600mmc/cintosteeltrack atfloorandceiling.2. Applyasinglelayerof12mmLafargeTaperededgeplasterboardto eachsideusing25mmdrywallscrewsspacedat220mmc/c.3. Tapeandjointaccordingtospecification.4. Refertostandardspecification.5. Acousticperformancerequiressealingbetweentrack,floor, ceilingandanyotherabutmentjoints.6. Staggertheplasterboardjointsinthesystem.
A: Lafarge 64mm steel stud
B: Lafarge 65mm steel track
C: 12mm Plasterboard
600,00
C: Lafarge 12mm Plasterboard
A: Lafarge 64mm steel stud
B: Lafarge 65mm steel track
LAFARGEPARTITIONSOLUTIONS 27
laFa
rg
EFix
ED P a
rtitio
n
LAFARGE GYPSUM DRYWALL LPF 64 - 60/160 MIN FIRE RATED INTERNALPARTITION SYSTEMNonloadbearingdrywallsystem15mmTechnicalFirecheckPlasterboard-onelayereachside
APPLICATION: CommercialandResidential
WALL PROPERTIES64mmstud60MinfireratingSoundinsulationreductionindex -40dBThickness -94mmApproximateweight -23kg/m²
MATERIAL USEDA - 64mmDrywallLafargesteelstudB - 65mmDrywallLafargesteeltrackC - 15mmFirecheckPlasterboard - 25mmDrywallScrews - LafargeDrywalljointingsystem - Floorandceilingfinishesasperspecification
APPLICATION DETAIL1. SetLafargesteelstudsspacedat600mmc/cintosteeltrack atfloorandceiling.2. Applyasinglelayerof15mmFirecheckTaperededgeplasterboardto
eachsideusing25mmdrywallscrewsspacedat220mmc/c.3. Tapeandjointaccordingtospecification.4. Refertostandardspecification.5. Acousticperformancerequiressealingbetweentrack,floor,ceiling
andanyotherabutmentjoints.6. Staggertheplasterboardjointsinthesystem.
A: Lafarge 64mm steel stud
B: Lafarge 65mm steel track
C: 15mm Fire Check board
600,00
A: Lafarge 64mm steel stud
C: Lafarge 15mm Firecheck Board
B: Lafarge 65mm steel track
LAFARGEPARTITIONSOLUTIONS 28
LafargE fIrE raTEd ParTITION SYSTEMS
LAFARGE GYPSUM DRYWALL LPF 64 - 60/260 MIN FIRE RATED INTERNALPARTITION SYSTEMNonloadbearingdrywallsystem12mmStandardPlasterboard-doublelayereachside
APPLICATION: CommercialandResidential
WALL PROPERTIES64mmstud60MinfireratingSoundinsulationreductionindex -45dBThickness -112mmApproximateweight -39kg/m²
MATERIAL USEDA - 64mmDrywallLafargesteelstudB - 65mmDrywallLafargesteeltrackC - 12mmTaperedEdgePlasterboard - 25mmDrywallScrews - LafargeDrywalljointingsystem - Floorandceilingfinishesasperspecification
APPLICATION DETAIL1. SetLafargesteelstudsspacedat600mmc/cintosteeltrack atfloorandceiling.2. Applyasinglelayerof12mmstandardplasterboardverticaltobothsidesusing
25mmdrywallscrewsspacedat220mmc/c,staggerjoints.3. Applya face layerof12mmstandardplasterboard toboth sides staggeringall
joints,using41mmdrywallscrewsspacedat220mmc/c.4. Tapeandjointaccordingtospecification.5. Refertostandardspecification.6. Acousticperformancerequiressealingbetweentrack,floor,ceilingandanyother
abutmentjoints.7. Staggertheplasterboardjointsinthesystem.
B: Lafarge 65mm steel track
A: Lafarge 64mm steel stud
C: 12mm Plasterboard
C: 12mm Plasterboard
600,00
C: Lafarge 12mm Plasterboard
A: Lafarge 64mm steel stud
B: Lafarge 65mm steel track
C: Lafarge 12mm Plasterboard
LAFARGEPARTITIONSOLUTIONS 29
laFa
rg
EFix
ED P a
rtitio
n
LAFARGE GYPSUM DRYWALL LPF 64 - 60/360 MIN FIRE RATINGINTERNAL PARTITION SYSTEMNonloadbearingdrywallsystem12,5mmTechnicalFirecheckPlasterboard-onelayereachside80kg/m³insulmattwiremeshsurfaceFibreblanket
WALL PROPERTIES64mmstud60MinfireratingSoundreductionindexwithinsulmattwiremeshsurfacedfibreblanket80kg/m³ -49dBThickness -89mmApproximateweight -30kg/m²
MATERIAL USEDA - 64mmDrywallLafargesteelstudB - 65mmDrywallLafargesteeltrackC - 12,5mmFirecheckBoard - 25mmDrywallScrews - LafargeDrywalljointingsystem - Floorandceilingfinishesasperspecification - Insulmattwiremeshsurfacedfibreblanketof80kg/m³
APPLICATION DETAIL1. SetLafargesteelstudsspacedat600mmc/cintosteeltrackatfloorandceiling.2. Applyasinglelayerof12,5mmFirecheckBoardverticaltoonesideusing
25mmdrywallscrewsspacedat220mmc/c.3. PositionInsulmattinsulationbetweenstuds,foldthetopoverandsecuretotop
trackbypositioningandfixingwithgalvanisedangle.4. Applyasinglelayerof12,5mmFirecheckBoardverticaltotheotherside
using25mmdrywallscrewsspacedat220mmc/c.5. Tapeandjointaccordingtospecification.6. Refertostandardspecification.7. Acousticperformancerequiressealingbetweentrack,floor,ceilingandany otherabutmentjoints.8. Staggertheplasterboardjointsinthesystem.
600,00
A: Lafarge 64mm steel stud
Insulmatt Insulation
B: Lafarge 65mm steel track
C: 12,5mm Fire Chec boardk
B: Lafarge 65mm steel track
A: Lafarge 64mm steel stud
Insulmatt Insulation
C: Lafarge 12,5mm Firecheck Board
LAFARGEPARTITIONSOLUTIONS 30
LafargE fIrE raTEd ParTITION SYSTEMS
LAFARGE GYPSUM DRYWALL LPF 64 - 120/1120 MIN FIRE RATED INTERNALPARTITION SYSTEMNonloadbearingdrywallsystem12,5mmTechnicalFirecheckPlasterboard -0,5mmgalvanisedsteelbetweendoublelayerofTechnicalFirecheckPlasterboardoneachside.
WALL PROPERTIES64mmstud120MinfireratingSoundreductionindex -48dBThickness -115mmApproximateweight -50kg/m²
MATERIAL USEDA - 64mmDrywallLafargesteelstudB - 65mmDrywallLafargesteeltrackC - 12,5mmTaperEdgeTechnicalFirecheckBoardD - 0,5mmgalvanisedsteelsheet - 25mmand41mmDrywallScrews - LafargeDrywalljointingsystem - Floorandceilingfinishesasperspecification
APPLICATION DETAIL1. SetLafargesteelstudsspacedat600mmc/cintosteelatfloorandceiling.2. Applyasinglelayerof12,5mmtaperededgeFirecheckPlasterboard
verticaltoonesideusing25mmdrywallscrewsspacedat220mmc/c.3. Apply0,5mmgalvanisedsteelsheettoeachside(min30mmoverlap).4. Applyafacelayerof12,5mmtaperededgeFirecheckPlasterboardto
bothsides.5. Tapeandjointaccordingtospecification.6. Refertostandardspecification.7. Acousticperformancerequiressealingbetweentrack,floor,ceilingand
anyotherabutmentjoints.8. Staggertheplasterboardjointsinthesystem.
600,00
B: Lafarge 65mm steel track
D: 0,5mm galvanised steel sheet
C: 12,5mm Fire Check board
A: Lafarge 64mm steel stud
C: 12,5mm Fire Check board
D: 0,5mm galvanised s eel sheet
0.5mm galvanised steel sheet
A: Lafarge 64mm steel stud
D: 0.5mm galvanised steel sheet
B: Lafarge 65mm steel track
Lafarge 12,5mm Firecheck Board
C: Lafarge 12,5mm Firecheck Board
LAFARGEPARTITIONSOLUTIONS 31
laFa
rg
EFix
ED P a
rtitio
n
LAFARGE GYPSUM DRYWALL LPF 64 - 120/2120 MIN FIRE RATED INTERNAL PARTITION SYSTEMNonloadbearingdrywallsystem15mmTechnicalFirecheckPlasterboard-doublelayereachside
WALL PROPERTIES64mmstud120MinfireratingSoundreductionindex -48dBThickness -124mmApproximateweight -45.5kg/m²
MATERIAL USEDA - 64mmLafargeDrywallsteelstudB - 65mmLafargeDrywallsteeltrackC - 15mmFirechecktaperededgeplasterboard - 25mmand41mmDrywallScrews - LafargeDrywalljointingsystem - Floorandceilingfinishesasperspecification
APPLICATION DETAIL1. SetLafargesteelstudsspacedat600mmc/cintosteeltrackatfloor andceiling.2. Applyasinglelayerof15mmTechnicalFirecheckPlasterboardvertical tobothsides.using25mmdrywallscrewsspacedat220mmc/c, staggerjoints.3. Applyafacelayerof15mmTechnicalFirecheckPlasterboardtoboth sidesstaggeringalljoints,using41mmdrywallscrewsspacedat
220mmc/c.4. Tapeandjointaccordingtospecification.5. Refertostandardspecification.6. Acousticperformancerequiressealingbetweentrack,floor,ceilingand
anyotherabutmentjoints.7. Staggertheplasterboardjointsinthesystem.8. Maximumpartitionheight4,5m.
600mm.
C: 15mm Fire Check board
A: Lafarge 64mm steel stud
B: Lafarge 65mm steel trackB: Lafarge 65mm steel track
A: Lafarge 64mm steel stud
C: Lafarge 15mm Firecheck Board
LAFARGEPARTITIONSOLUTIONS 32
LafargE fIrE raTEd ParTITION SYSTEMS
C: Lafarge 15mm Firecheck Board
LAFARGE GYPSUM DRYWALL LPF 102 - 60/160 MIN FIRE RATED INTERNALPARTITION SYSTEMNonloadbearingdrywallsystem15mmTechnicalFirecheckPlasterboard-onelayereachside
APPLICATION: Residential
WALL PROPERTIES102mmstud60MinfireratingSoundinsulationreductionindex -40dBThickness -132mmApproximateweight -24kg/m²
MATERIAL USEDA - 102mmLafargeDrywallsteelstudB - 103mmLafargeDrywallsteeltrackC - 15mmStandardTaperededgePlasterboard - 25mmDrywallScrews - LafargeDrywalljointingsystem - Floorandceilingfinishesasperspecification
APPLICATION DETAIL1. SetLafargesteelstudsspacedat600mmc/cintosteeltrackat floorandceiling.2. Applyasinglelayerof15mmFirecheckTaperededgeplasterboardto eachsideusing25mmdrywallscrewsspacedat220mmc/c.3. Tapeandjointaccordingtospecification.4. Refertostandardspecification.5. Acousticperformancerequiressealingbetweentrack,floor,ceilingand anyotherabutmentjoints.6. Staggertheplasterboardjointsinthesystem.
A: Lafarge 102mm steel stud
B: Lafarge 103mm steel track
C: 15mm Fire Check boar
600,00
A: Lafarge 102mm steel stud
B: Lafarge 103mm steel track
C: Lafarge 15mm Firecheck Board
LAFARGEPARTITIONSOLUTIONS 33
laFa
rg
EFix
ED P a
rtitio
n
LAFARGE GYPSUM DRYWALL LPF 102 - 120/1120 MIN FIRE RATED INTERNALPARTITION SYSTEMNonloadbearingdrywallsystem15mmTechnicalFirecheckPlasterboard-Doublelayereachside
APPLICATION: Residential
WALL PROPERTIES102mmstud120MinfireratingSoundinsulationreductionindex -50dBThickness -162mmApproximateweight -46,5kg/m²
MATERIAL USEDA - 102mmDrywallLafargesteelstudB - 103mmDrywallLafargesteeltrackC - 15mmFirecheckTaperededgePlasterboard - 25mmand41mmDrywallScrews - LafargeDrywalljointingsystem - Floorandceilingfinishesasperspecification
APPLICATION DETAIL1. SetLafargesteelstudsspacedat600mmc/cintosteeltrackatfloorandceiling.2. Apply a single layer of 15mmTechnical FirecheckPlasterboard vertical to both
sidesusing25mmdrywallscrewsspacedat220mmc/c,staggerjoints.3. Applyafacelayerof15mmTechnicalFirecheckPlasterboardtobothsides.4. Tapeandjointaccordingtospecification.5. Refertostandardspecification.6. Acousticperformancerequiressealingbetweentrack,floor,ceilingand
anyotherabutmentjoints.7. Staggertheplasterboardjointsinthesystem.8. MaximumPartitionheight4,5m.
600mm.
A: Lafarge 102mm steel stud
B: Lafarge 103mm steel track
C: 15mm Fire Check board
A: Lafarge 102mm steel stud
B: Lafarge 103mm steel track
C: Lafarge 15mm Firecheck Board
LAFARGEPARTITIONSOLUTIONS 34
LAFARGEPARTITIONSOLUTIONS 35
laFa
rg
E FinESSE
® r
Emo
un
taBlE
P ar
tition
SyStEm
LAFARGEPARTITIONSOLUTIONS 36
TECHNICaL dETaILSIntroductionThehighqualityFinesse®Aluminiumcomponentsallowdesignersandspaceplannerstocombinefullheightandlowlevelpartitionsusingonesysteminthedesignofworkstations.
TheLafargeFinesse®RemountablePartitionSystemisdesignedforanever-changingworldwhereorganisationsconstantlyevaluateandimprovetheiroperations,andwiththem,theirpeopleandofficeenvironments.
TheflexibilityoftheLafargeFinesse®RemountablePartitionSystemallowsarchitects,designers,spaceplannersandthelike,tocreateworkingenvironmentsofvaryingstylesandheights, basedupon requirements for sound,fire-rating,privacyand space.Theunique aluminium section design, incorporating the Finesse® clip fitting sections,eliminatestheneedfordrillingandscrewinginmostapplications.
Key Features • Easyinstallation.• Fullyre-locatableincomponentform.• Superbdetailingandfinishing.• Comparativeacousticqualities.• Pencilline,covertrimsorflushwallappearance.• Extensivevarietyofpanelfinishes.• Centre,doubleoroffsetglazing.• Integralblinds.• Concealedfixedskirting.• Curvedandangularcornerprofiles.
• Strongsubstantialprofiles.• ManufacturedtoBS5750/ISO9002QualityStandards.• Integralwiremanagementsystems.• PowerSkirting30minSABS0177:Part2-2005.• Fullrangeofmouldedcappingpieces.
Planning Finesse®offersunprecedentedfreedominplanningtheoptimumworkplace,freeingthedesignersfromrestraintsplaceduponthembyothersystems,whileatthesametimeallowingthemostefficientuseoffloorspace.
The built-in flexibility of the Lafarge Finesse®Remountable Systemallows for easyadaptationoradjustmentshouldthisberequired.
Wire ManagementTheLafargeFinesse®RemountablePartitionSystemisdevelopedtoaccommodatetherequirementsof themost technologicallyadvancedofficeenvironment.Allelectrical,dataandcommunicationcablescanbeplacedwithinthespaciouscavitiesprovidedbytheframework,oralternativelyinthedesignedpowerskirtingsituatedatthebaseoratapreferredheightwithinthePartitionSystem.
InstallationThesystemmustbeinstalledbycontractorswhoaretrainedandapprovedbyLafargeGypsum(Pty)Ltd.
LAFARGEPARTITIONSOLUTIONS 37
laFa
rg
E FinESSE®
r
Emo
un
taBlE Pa
rtitio
n SyStEm
POSTS
Centreglazing
Doubleglazing
4 Way Box Post showing partition board and full heightglazing details.
Doubleglazing
Offset glazing
Centreglazing
3 Way Y Post showing three different floorglazing details.
Centreglazing
Main Post showing partition board and centreglazing details.
Centreglazing
Main Post showing centre glazing details .
Centreglazing
Door Stop
135ϒ/45ϒ corner post showing Door Stop and CentreGlazing details.
Lafarge Plasterboard
Lafarge Plasterboard
LAFARGEPARTITIONSOLUTIONS 38
PrIMarY aLUMINIUM SECTIONS
Outer Glazing Bead Die 6441 (offset/double glazing)
(FA 650)
12mm
Double Glazing ChairDie 6440 (FA 670)
42mm
6
Centre Glazing BeadDie 1842 (FA 620)
35mm
Centre Glazing ChairDie 1841 (FA 600)
35mm
1 88mm
40
mm
76mmStrong Post
Die 6322 (FA 500)
2 88mm
40
mm
76mmMain Post
Die 6323 (FA 510)
Offset Glazing ChairDie 1828 (FA 680)
60mm
Glazing
Sections not drawn to scale
4 Terminations 5
76mm Door Stop
Die 6325 (FA 531)
Door Stop
3
Cover Trim27mm Die 631440mm Die 6356 (FA685)
27
mm
/40
mm
Skirting
Die 6624
10
0m
m
PVC Skirting Infill
20
mm
61
mm
20mm
44
mm
76mmAngled Infill
Die 1824 (FA 544)
76mmFA540 Curved InfillDie 6326 (FA 540)
Flat InfillDie 1829 (FA 542)
76mm
LAFARGEPARTITIONSOLUTIONS 39
laFa
rg
E FinESSE®
r
Emo
un
taBlE Pa
rtitio
n SyStEm
ALUMINIUM ABUTMENTS
7
76mm
88m
m
90ϒ Corner PostDie 1825(FA 560)
8
88mm
76mm
95
mm
135ϒ/45ϒ Corner PostDie 6324 (FA 550)
9
76
mm
4 Way PostDie 53974
88
mm
76mm
88mm
10
88mm
76
mm
76mm
3 Way “Y” PostDie 6343 (FA 580)
11
3 Way Box PostDie 6342 (FA 570)
109mm
88
mm
76
mm
76mm
LAFARGEPARTITIONSOLUTIONS 40
COMPONENTS aNd dIagraMS
Fixing
Timber Packers(55mm x 24mm, 55mm x 16mm)
MXG Bubble Seal Gasket(grey or black)
Revealededge Grid ClipTee
Lay in Grid ClipTee
B
Internal Fixing Brackets
C
Dimension of track & stud in relation to board thickness
Boardmm
9.012.015.0
565045
554843
TRKFrictionTrack
DSTEStud
Table A
DSTE StudTRK Friction Track
A
Finesse Hinge Located in Door Stop
Main Post/Strong Post
Position of Fixing BracketMain Post
D
Rolled Galvinised Materialcode FCL Clamping Strip
Finesse Lock Box
Power Skirting accessories as per Crabtree and Clipsal 2000 series range.
20
200
88
76
Two sections of power skirtingplaced back to back to achievedouble volume Power Skirting.
Power SkirtingDie 28456
Power SkirtingDie 28456
Partition Board (Thickness refer table A above)
TRK Friction Track (Dimension refer table A above)
Ezee-Clip
Cover PlateDie 1829
Double sided tape
Floor or Transom Level
Flat Infill Die 1826 used fordesktop applications
19
mm
4mm
15
.3m
m
LAFARGEPARTITIONSOLUTIONS 41
HEAD AND FLOOR DETAIL1 Solid Head Detail Using Partition Board 1. MainPostDie6323(FA510)2. TRKFrictionTrack(DimensionrefertableAPage41)3. DSTEStud(DimensionrefertableAPage41)4. LafargePlasterboard(ThicknessrefertableAPage41)5. Fixing(mechanical/gridclip) TypicalDetailAppliestoWallAbutments
2 Solid Floor Detail Using Partition Board1. TRKFrictionTrack(DimensionrefertableAPage41)2. DSTEStud(DimensionrefertableAPage41)3. LafargePlasterboard(ThicknessrefertableAPage41)4. Fixing(mechanical/gridclip)5. 40mm/75mm/100mmSkirting6. Fixing(mechanical/velcro)
GLAZING DETAIL3 Full Height Centre Glazing 1. MainPostDie6323(FA510)22. CentreGlazingChairDie1841(FA600)3. CentreGlazingBeadDie1842(FA620)4. MXGBubbleSealGasket5. 6mmGlass6. Floorlevel ForHeadDetail,MainPostfixedasDetail1
4 Solid to Offset Glazing1. MainPostDie6323(FA510)2. OffsetGlazingChairDie1828(FA680)3. OuterGlazingBeadDie6441(FA650)4. MXGBubbleSealGasket5. 4-6mmGlass6. LafargePlasterboard(ThicknessrefertableAPage41)7. TRKFrictionTrack(DimensionrefertableAPage41)8. DSTEStud(DimensionrefertableAPage41)9. Fixing TypicalDetailAppliestoWallAbutments
5 Solid to Double Glazing 1. MainPostDie6323(FA510)2. DoubleGlazingChairDie6327(FA670)3. OuterGlazingBeadDie6441(FA650)4. MXGBubbleSealGasket5. 4-6mmGlass6. LafargePlasterboard(ThicknessrefertableAPage41)7. TRKFrictionTrack(DimensionrefertableAPage41)8. DSTEStud(DimensionrefertableAPage41)9. Fixing
9 5
8
6
1
7
2
34
243 34
5
8
1
7
6
9
1
2
3
6
4
5
7
3
2
45
1
6
5
1
2
3
4
DETAILS
laFa
rg
E FinESSE®
r
Emo
un
t aBlE P a
rtitio
n SyStEm
LAFARGEPARTITIONSOLUTIONS 42
dETaILS
DOOR FRAME DETAIL 6 Full Height Door Head Detail 1. MainPostDie6323(FA510)2. DoorStopDie6325(FA531)3. MXGBubbleSealGasket4. 40mmDoor5. Fixing
7 Door Head with Partition Board Above 5 1. MainPostDie6323(FA510)2. DoorStopDie6325(FA531)3. MXGBubbleSealGasket4. 40mmDoor5. LafargePlasterboard(ThicknessrefertableAPage41)6. TRKFrictionTrack(DimensionrefertableAPage41) Note:BeforefixingMainPostDoorTransomcutand
positionPartitionBoardabove
8 Door Mullion with Partition Board 1. StrongPostDie6322(FA500)2. DoorStopDie6325(FA531)3. MXGBubbleSealGasket4. 40mmDoor5. LafargePlasterboard(ThicknessrefertableAPage41)6. TRKFrictionTrack(DimensionrefertableAPage41)7. TimberPacker(55mmx16mm)8. Fixing9. FinesseHinge
9 Door Mullion with Centre Glazing 1. StrongPostDie6322(FA500)2. CentreGlazingChairDie1841(FA600)3. CentreGlazingBeadDie1842(FA620)4. MXGBubbleSealGasket5. 4-6mmGlass6. DoorStopDie6325(FA531)7. 40mmDoor8. TimberPacker(55mmx16mm)9. Fixing10. FinesseHinge
10
9
2
3
5
6
4
4
7
1
8
8
9
2
3
5
6
4
1
7
2
56
34
1
5
4
1
2
3
LAFARGEPARTITIONSOLUTIONS 43
10 Board Joint Details1. TRKFrictionTrack(DimensionrefertableAPage24)2. DSTEStud(DimensionrefertableAPage24)3. LafargePlasterboard(ThicknessrefertableAPage24)4. ClampingStrip5. Die6314CoverTrim27mm6. Die6356CoverTrim40mm(FA685)7. Fixing18. TaperededgeLafargePartitionBoard9. Tapeandjointed
*NBStaggeredjointsimprovenoisereduction.
laFa
rg
E FinESSE®
r
Emo
un
taBlE Pa
rtitio
n SyStEm
A) Wall Abutment detail
7
6
1
3
4
B) Jointing of boards
21
3
9
7
8
5
4
all
LAFARGEPARTITIONSOLUTIONS 44
dETaILS
11 90° Corner Post Showing Clip on Door Stop and Board Detail 1. 90°CornerPostDie1825(FA560)2. DoorStopDie6325(FA531)3. MXGBubbleSealGasket4. 40mmDoor5. LafargePlasterboard(ThicknessrefertableAPage41)6. TRKFrictionTrack(DimensionrefertableAPage41)7. Fixing698. TimberPacker(55mmx24mm)9. FinesseHinge2
12 3 Way Box Post Showing Clip on Door Stop, Centre Glazing and Curved Infill Detail 1. 3WayBoxedPostDie6342(FA570)2. CentreGlazingChairDie1841(FA600)23. CentreGlazingBeadDie1842(FA620)4. MXGBubbleSealGasket55. 4-6mmGlass46. DoorStopDie6325(FA531)7. 40mmDoor8. CurvedInfillDie6326(FA540)
13 3 Way “ Y “ Post Showing Clip on Door Stop, Double Glazing and Flat Infill Detail1. 3Way‘Y’PostDie6343(FA580)42. OffsetGlazingChairDie1828(FA680)3. OuterGlazingBeadDie6441(FA650)34. MXGBubbleSealGasket45. DoorStopDie6325(FA531)76. 40mmDoor7. 4-6mmGlass8. FlatInfillDie1826(FA542)
14 135°/45° Corner Detail Showing Clip on Door Stop and Board Details 1. 135°/45°CornerPostDie6324(FA550)2. DoorStopDie6325(FA531)3. MXGBubbleSealGasket4. 40mmDoor5. LafargePlasterboard(ThicknessrefertableAPage41)6. TRKFrictionTrack(DimensionrefertableAPage41)7. FinesseHinge8. TimberPacker(55mmx24mm)9. Fixing
15 4 Way Box Post Showing Clip on Door Stop\Glazing\Angle Infill and Board Detail 1. 4WayBoxedPostDie539742. CentreGlazingChairDie1841(FA600)3. CentreGlazingBeadDie1842(FA620)4. MXGBubbleSealGasket5. 4-6mmGlass6. DoorStopDie6325(FA531)7. 40mmDoor8. LafargePlasterboard(ThicknessrefertableAPage41)9. TRKFrictionTrack(DimensionrefertableAPage41)10. AngledInfillDie1824(FA544)
8
9
9
42
3
65
1
8
3
5 4
2
64
1
7
7
4
5
2
43
8
1
6
7
8
96
5
42
3
1
8
7
106
4
42
5 3
1
9
LAFARGEPARTITIONSOLUTIONS 45
SPECIFICATIONS
All aluminium and steel components for the Lafarge Finesse®RemountablePartitionSystemtobeinaccordancewithcomponentslistedindiagrams1-6underPrimaryAluminiumSectionsonPage39,7-11underAluminiumAbutmentsonPage40andA-DunderComponentsandDiagramsonPage41andshallbeinstalledinstrictaccordancewiththedesignspecificationandmanufacturersinstructions.
Installation Guide Solid Partition • SecureMainPosttoceiling,eitherbypositivefixorusing
CeilingGridclips.• SecureMainPosttoverticalabutments,oralternativepage
26Fig10a.• AtjunctionofhorizontalandverticalMainPostsposition,
internalfixingbracketbetweennibsprovided,alignsections,andfixbrackettobothsectionsthroughpredrilledholesprovidedreferpage24Fig.D, InternalFixingBrackets.Wafertextor3210poprivetscanbeused.
• CentrallybetweennibsprovidedinMainPostsfixthegalvanisedfrictiontrack.
• PlumbdownpositionofgalvanisedFrictionTrack.• SecuregalvanisedFrictionTracktoflooreitherbypositivefix
orusevelcrooncarpet/doublesidedtapeontiledfloor.• Position DSTE Stud vertically in the track at ceiling and floor,
spacedat600mmfor12mmboard/400mmfor9,5mm LafargePlasterboard.• Measureheightfromfloortoceiling,deduct10mm,andcut
partitionboardtosize.• WheninstallingLafargePlasterboards: 1.LocatepartitionboardbetweenFrictionTrackandMain
Postslideupintoposition,or 2.PositionboardagainstFrictionTrack,bowoutwards,and
locatebetweenFrictionTrackandMainPostathead. Slideboardintopositionatverticalaluminiumsections.
• Ensurethatastudisalwayspositionedcentrallyatverticalboardjoints.
• SecureClampingStripoverboardjoint.(ClampingStripsmustbesaw cut to hold shape). Friction fixAluminiumCoverTrimontoClampingStrip.
• To fix Clamping Strip for horizontal details, peel pop rivets arerecommended.FrictionfixAluminiumskirting/covertrim
ontoclampingstrip.
• 100mmskirtingtobefixedbydrywallscrewandPVCinfillinsert.• ItisrecommendedthatLafargePlasterboardsbecoveredpriorto
installation.Thisminimisesonsiteworkandmess,althoughplainLafargePlasterboardscanbefittedfordecorationinsitu.RefertoHeadandFloorDetailsFig.1.2page24/Boardjointdetailspage25DetailB.
Door Frames PositionStrongPostsvertically fromfloortoundersideofMainPost,secure Main Post to floor with Internal Fixing Brackets, short leg ofInternal Fixing Bracket to face door opening. Cut door Transom tosize,positionbetweenverticalStrongPostsandsecure intopositionwith Internal Fixing Brackets. Internal Fixing Brackets to be locatedbetween nibs provided inAluminium extrusions. It is recommendedthat factory machine finished Door Stop header sections are used,oralternativelymeasureopeningandcutDoorStopsectionstosize,check door hand and mitre accordingly (clip Door Stop onto loosepieceofStrongPost,holdingintopositionforanaccuratemitrebeforecutting).BubbleSealGaskettobelocatedintopositiononDoorStopsectionsbeforeinstallation.ClipDoorStopsectionsintoStrongPosts/MainPosts.PositionFinesseHingeandscrew/poprivetintoposition,screw/poprivettobelongenoughtoreachcentralwebofStrongPost.ForfullheightdoorsitisrecommendedthataTimberPackerbeusedbehindHinges.CutholeforLockBoxandfixLockBoxintoposition.Forstandarddoorwithpanelabove,itisrecommendedthatpanelabovedoorbeglazed.RefertoDoorFramedetailsonpage25.
Glazing A: Preparation PositionMainPostverticallyfromfloortoundersideoftopMainPost,secure to floor and to top Main Post with Internal Fixing Brackets.Forfullheightglazing,secureMainPostonfloorwithInternalFixingBrackets,betweenverticalMainPosts,opensectiontofacedown.
For half glazed panels secure Main Post at level required, betweenvertical Main Posts. Internal Fixing Brackets to be used to securesectionstogether.
B: Finishing RefertoStep1andStep2below(horizontalglazingsectionstobeinstalledfirst.)
laFa
rg
E FinESSE®
r
Emo
un
taBlE Pa
rtitio
n SyStEm
Showing measuring position for verticleglazing chair and glazing bead
Step 2Step 1
Showing measuring position for horizontalglazing chair and glazing bead
Refer to Glazing details page
LAFARGEPARTITIONSOLUTIONS 46
SPECIfICaTIONS
C: Glass The Lafarge Finesse® Remountable Partition System clip in glazing sections, includingtheBubbleSealGasket,havebeendesignedtoacceptglassfrom4mmto6mmnominalthickness.Wherethickerglassisinstalled,theBubbleSealGaskettotheGlazingChaircanbeomitted.Alternatively,WoodpilecanbeinstalledinsteadoftheBubbleSealGasket.
Complementary Accessories AfullrangeofcomplementaryaccessoriesareavailableintheformofRounded90°CornerPost,135°/45°CornerPost,3WayBoxPost,3Way“Y”Post,4WayBoxPost,includinga full range of moulded Capping Pieces to close open ends ofAluminium sections inlowlevelapplications.Variousconfigurationsusingthefull rangeofadd-onfittingsareavailable.Whenusedinapartitionwallapplication,thesesectionstorunfullheightfloortoceiling.RefertoJunctionAccessories.
Aluminium AllAluminiumsectionsareextrudedfromgrade6063ArchitecturalAluminiumavailableinMill,AnodizedorPowdercoatedfinishes.
Power Skirting Power Skirting Sections are available in Aluminium which complement the Lafarge Finesse®RemountablePartitionSystem. 1: FloororTransomfixedwithinpartitionthickness. Refertopage41. 2: Wallmounted60mmdeepPowerSkirting.Die6420. WallFinishesArangeofVinylsareavailable,pleasecontactourbranchesfordetails.
Low Level Movable Office Partition Due to the flexibility and range of accessories available in the Lafarge Finesse® RemountablePartitionSystem,lowlevelmovableofficepartitionscaneasilybeassembled.
Lafarge Finesse® Remountable Partition System.SupplyandinstallLafargeFinesse®RemountablePartitionSystemfromLafargeGypsumwithoverallthicknessof88mmcomprisingofinternalframingformedof48mmFinesse®galvanisedsteel studsclipped intopositionat600mmcentres intoFinesse®galvanisesteelfrictiontracktopandbottom,includingwherenecessary,anyadditionalFinesse®steel friction track to be secured to aluminiumdoor openings, glazing, angles corners,head,terminationandfloor.
The internal steelframing is tobedressedbothsideswith12mmthick1195mmwidepre-laminatedsquareedgeLafargeplasterboard(specificfinish)insinglelengthstosuiteheightandsecuredtotheFinesse®steelstuddingwithgalvanisedsteelclampingstripsfinishedwithaluminiumclip-oncover trim.All exposedaluminium,head sections,wallsections,glazingsections,doorframes,cornersections,covertrims,clip-inglazing,clip-indoorandskirtingaretobeformedof(naturalanodized/colouranodized/powercoatedtospecificcolour,aluminiumsections.Maximumheightof3600mm.
LAFARGEPARTITIONSOLUTIONS 47
laFa
rg
E Co
mPo
un
DS
Lafarge Jointing PlasterdescriptionLafarge JointingPlaster isa jointingcompoundused togetherwithfibatapeatthetaperededgejointsofLafargeplasterboards.
features• Itprovideseaseofapplication• Specialadditiveswithinitsbodydelaystheabsorptionofjointwater
bytheplasterboardsurface• Ithasafillerfunctionwhichcreatesasmoothsurfacefinishdueto
specialgraindistribution• Ithashighbindingfeatures• Ithasaflexiblefeaturewhicheliminatesthechanceofcrackingonthe
jointsandthereforeenablestheapplicationsurfacetoworkuniformly• Since it isabreathingmaterial, itcreatesahealthyatmosphereby
balancingthemoisturerate
SpecificationsWater/PlasterMixingRatio: 6-6.5Lwaterto10kgWorkingTime: 60minutesSettingTime: 115–145minutesShelfLife: 1yearCoverageRatio: 40lmper20kgbag (basedon2coats)PackagingColour: DarkOrangeUse: Internalonly
Mixing Instructions1. Usecleanwaterinacleancontainer2. SlowlypourLafargeJointingPlasterPremiumintocleanwater3. AllowLafargeJointingPlasterPremiumtostand/soakfor2minutes
beforemixing4. Mixthemortartoobtainlumpfreesmoothpaste5. Donotoverstir6. Donotmixwithyourhands7. Cleantoolsandmixingcontaineraftereachmix8. DonotmixmoreLafargeJointingPlasterPremiumthenyoucanuse
in60minutes
application Instructions• ApplyLafargeJointingPlasterPremiumtoacleandustfreesurface• Applyproducttoplasterboardjointstospecification
recommendations- Uselow-speedmechanicalmixerormixmanually- Donotaddanywaterorplastertothemortaraftermixing- Donotapplywhentemperatureisbelow5°Candabove40°C- NevermixLafargeJointingPlasterPremiumwithanyotherproduct ormaterial- LafargeJointingPlasterPremium–Pre-fillingshouldbedonetothe
jointsthatarewider3mm
LAFARGEPARTITIONSOLUTIONS 48
Lafarge Jointing Plaster StandarddescriptionLafargeJointingPlasterStandardisajointingcompoundusedtogetherwithfibatapeatthetaperededgejointsofallLafargeplasterboards.
features• Itprovideseaseofapplication• Specialadditiveswithinitsbodydelaystheabsorptionofjointwaterby
theplasterboardsurface• Ithasafillerfunctionwhichcreatesasmoothsurfacefinishduetospecial
graindistribution• Ithashighbindingfeatures• Since it is a breathing material, it creates a healthy atmosphere by
balancingthemoisturerate.
SpecificationsWater/PlasterMixingRatio 2partspowderto1partwaterbyweightWorkingTime 70–130minutesSettingTime 115–145minutesShelfLife 6monthsPackaging 20kgCoverageRatio 40lmper20kg(basedon2coats)PackagingColour OrangeUse Internalonly
Mixing Instructions1. Usecleanwaterinacleancontainer2. SlowlypourLafargeJointingPlasterStandardtowaterinamixingratioof
2partspowderto1partwaterbyweight3. Allow Lafarge Jointing Plaster Standard to stand/soak for 2 minutes
beforemixing4. LafargeJointingPlasterStandardcanbemixedbyhandorbyanelectric
whisk5. Mixfor2-3minutesuntilacreamypasteisachieved6. Donotoverstir7. Donotmixwithyourhands8. Cleantoolsandmixingcontaineraftereachmix9. DonotmixmoreLafargeJointingPlasterStandardthenyoucanusein 50minutes
application Instructions• ApplyLafargeJointingPlasterStandardtoacleandustfreesurface• Applyoverfibatape
recommendations- Uselow-speedmechanicalmixerormixmanually- Donotaddanywaterorplastertothemortaraftermixing- Donotapplywhentemperatureisbelow5°Candabove40°C- NevermixLafargeJointingPlasterStandardwithanyotherproductormaterial- LafargeJointingPlasterStandard–Pre-fillingshouldbedonetothejoints
thatarewider3mm
Lafarge finishing PlasterdescriptionTheLafargeFinishingPlasterisanunder-paintfinallayerfinishingplasterwithhighadhesivecharacteristicsonLafargeplasterboardapplyfibatapetojoints
features• TheLafargeFinishingPlaster isusedtomakeanytypeofwalland
Lafargeplasterboardsurfacereadytopaint• Thelongusageperiodallowseasyandfaultlessapplication• SpecialadditivesusedinitsbodydelaystheLafargeFinishingPlaster mortarswatertobeabsorbedfromtheexistingground• Ithasapuffyformwhichmakesforeaseofapplication• It provides a hard and smooth surface due to its special grain
distribution• Since it isabreathingmaterial, itcreatesahealthyatmosphereby
balancingthemoisturerate• Itmakesforeasyuseinhumidenvironments
SpecificationsWater/PlasterMixingRatio: 6,5–7lwaterto10kgWorkingTime: 60minutesSettingTime: Startswithin20minutesShelfLife: 1yearPackaging: 25kgApplicationThickness: 1to3mmCoverageRatio: 1kgfor1mmofapplicationperm²PackagingColour: PurpleUse: Internalonly
Mixing Instructions1. Usecleanwaterinacleancontainer2. SlowlypourLafargeFinishingPlasterintocoldcleanwater3. Ifusingadeepmixingcontainersaturatethewaterwith LafargeFinishingPlaster4. Allow Lafarge Finishing Plaster to stand/soak for 2 minutes beforemixing5. Mixtoobtainhomogenousmixwithnolumpsandasmoothpaste6. Donotoverstir7. Donotmixwithyourhands8. Cleantoolsandmixingcontaineraftereachmix9. DonotmixmoreLafargeFinishingplasterthenyoucanuse in60minutes
application Instructions• ApplyLafargeFinishingPlastertoacleandustfreesurface• Applypastetoareawithtroweltospecifiedthickness• Polish• For1mmofapplicationper1m²approximately1kgof LafargeFinishingPlasterisconsumed
recommendations- Uselow-speedmechanicalmixerormixmanually- Donotaddwaterorplastertothemortaraftermixing- Donotapplywhentemperatureisbelow5°Canabove40°C- NevermixLafargeFinishingPlasterwithanyotherproduct
LAFARGEPARTITIONSOLUTIONS 49
Mixing Instructions
1. Usecleanwaterinacleancontainer2. SlowlypourLafargeSkimStone/LafargeSkimLitePlasterinto cleanwaterandsaturatethewater3. Allow Lafarge Skim Stone/Lafarge Skim Lite Plaster to stand/soak
beforemixing4. Mixtoobtainhomogenousmixwithnolumpsandasmoothpaste5. Donotoverstir6. Donotmixwithyourhands7. Cleantoolsandmixingcontaineraftereachmix8. DonotmixmoreLafargeSkimStone/LafargeSkimLiteplasterthen
youcanusein90minutes
application Instructions
• ApplyLafargeSkimStone/LafargeSkimLitePlaster toacleandustfreesurface
• Applypastetoareawithtroweltospecifiedthickness (recommended1-3mm)• Polish• Forbestresultsonconcrete/cementplasteredwall -Cleanofloosedustparticlesandmoisture -Applywaterbasesealertosurface -Allowtodry -ApplyLafargeSkimStone/LafargeSkimLite -Allowtodry -CoatwithSealer“impregnatedwhite”asbasecoat -Paintwithwaterbasedpaint
recommendations
- Lafarge Skim Stone – utilising 15/17 litres of water in a cleancontainer,add33kgofLafargeSkimStone
- LafargeSkimLite–utilising20/22 litresof cleanwater ina cleancontainer,add40kgofLafargeSkimLite
- Donotapplywhentemperatureisbelow5°Canabove40°C
Lafarge Skim StoneSpecifications
Lafarge Skim LiteSpecifications:
Water/PlasterMixingRatio AddinLafargeSkimStoneto cleanwater.Allowtosoak
StirslowlytoalumpfreemixtureWorkingTime 60to90minutesSettingTime 90to120minutesShelfLife 6monthsPackaging 33kgCoverageRatio 1-3mm–18m²,5-6mm–10m² 12-13mm–3m²(per33kbag)ApplicationThickness 1to13mmPackagingColour YellowUse Internalonly
Water/PlasterMixingRatio AddinLafargeSkimStoneto cleanwater.Allowtosoak StirslowlytoalumpfreemixtureWorkingTime 45to60minutesSettingTime 90to120minutesShelfLife 6monthsPackaging 40kgCoverageRatio 1-3mm–22m²,5-6mm–12m² 12-13mm–4m²(per40kgbag)ApplicationThickness 1to13mmPackagingColour BlueUse Internalonly
Lafarge Skimming Compounds
fields of UseInterior areas
• PlasterboardCeilings• PlasterboardWalls• CementRenderedWalls• Brickwalls
description:
TheLafargeSkimmingCompoundsareusedasfinishingcompoundsinskimfinishandcanbeappliedforinternaluseonly.
LAFARGEPARTITIONSOLUTIONS 50
Application Plasterboard Fiba Full Plaster Cement Bonding Brick Bonding Paited Bonding Paint Paint
Joints Tape Skim Board Surface Agent Surface Agent Surface Primer Application Primer
PVASolvent
PremiumJointingPlaster √ √ √ √ √
StandardJointingPlaster √ √ √ √ √
FinishingPlaster √ √ √ √ √ √ √ √ √ √ √ √
SkimStonePlaster √ √ √ √ √ √ √ √ √ √ √
SkimLitePlaster √ √ √ √ √ √ √ √ √ √ √
LafargeGypsumSA(Compounds)
all lafarge gypsum CompounDs are eCospeCifier listeD.
LAFARGEPARTITIONSOLUTIONS 51
laFa
rg
E g
yPSu
m Bu
ilDin
g
Solu
tion
S For
liFE
LAFARGEPARTITIONSOLUTIONS 52
braNCHESGAUTENG BRANCHESHead Office18BariumStreet,AlrodeExt7,1450POBox167025,Brackendowns,1454Tel:(+2711)3894500Fax:(+2711)8646816
Roodekop4BerryRoad,RoodekopPOBox167025Brackendowns,1454Tel:(+2711)8652390Fax:(+2711)8652398BranchManager:CheryllvanOnselen
East RandJamelaPark,No.60DenneRoadHughesExt21,BoksburgTel:(+2711)8261707Fax:(+2711)8261708BranchManager:RianavanStaden
Pretoria12AChurchStreet,PretoriaCentral,0001POBox48159,Hercules,0030Tel:(+2712)3252408Fax:(+2712)3252409BranchManager:SonjaFrancis
Pretoria East219BBatteryStreet,WillowsBusinessPark,Silverton,Pretoria,0127Tel:(+2712)8031772Fax:(+2712)8031779BranchManager:PatrysJoerning
TroyevilleNo.24thStreet,Doornfontein,JohannesburgTel:(+2711)4024747Fax:(+2711)4024749BranchManager:PotipharEsau
WynbergCnrAndriesNorth&ChadwickStreetWynberg,SandtonTel:(+2711)4448020Fax:(+2711)4448077BranchManager:RonaldMoffatt
COASTAL BRANCHESCape Town34BCochraneAvenue,LovemoreComplexGunnersCircle,Epping1CapeTown,7405POBox68,Epping,7405Tel:(+2721)5342039Fax:(+2721)5341803BranchManager:TerenceDomingo
DurbanUnit4&5GridHeightOfficePark,No.11RiverHorseClose,RiverHorseValleyBranchManager:AlanRayneCell:0827732115SalesRepresentative:GerhardMeyCell:0827835058
GeorgePWBothaBoulevard,Erf24964SteinhoffIndustrialPark,GeorgeTel:(+2744)8781578/1461Fax:(+2744)8781583BranchManager:JeanneCahill
Port ElizabethCnrFettesRoad&HarrowerRoadNorthEnd,POBox2788NorthEnd,PortElizabeth,6056Tel:(+2741)3732295Fax:(+2741)3730075BranchManager:WayneMulder
INLAND BRANCHESBloemfontein9PineStreet,OldIndustrialAreaBloemfontein,9300,POBox692Bloemfontein,9300Tel:(+2751)4471024Fax:(+2751)4471074BranchManager:MarioLategan
Nelspruit8SilvaStreet,WestAcres,Ext11Nelspruit,POBox706,Nelspruit,1200Tel:(+2713)7522129Fax:(+2713)7522160BranchManager:HaleyLewis
Polokwane86SiliconStreetLadina,Polokwane,0742Tel:(+2715)2932985/83/26Fax:(+2715)2932928BranchManager:CoenieEngelbrecht
EXPORT BRANCHESBotswanaPlot22016UnitB&C,Gaberone,WestIndustrial,PrivateBag003,Suite466Mogoditshane,BotswanaTel:(00267)3167732/34Fax:(00267)3167753AdminBranchManager:ReginahKapembwa
MaputoRuaDasEstancias344,Warehouse3&4Maputo,MoçambiqueTel:00258(1)310063Fax:00258(1)310068BranchManager:EllahJeyacheya
LAFARGEPARTITIONSOLUTIONS 53
LAFARGEPARTITIONSOLUTIONS 54
NOTES
LAFARGEPARTITIONSOLUTIONS 54
LAFARGEPARTITIONSOLUTIONS 55
LAFARGEPARTITIONSOLUTIONS 55
LAFARGE GYPSUM HEAD OFFICE18BariumStreet,AlrodeExt7,1449,POBox167025,Brackendowns,1454Tel:(+2711)3894500,Fax:(+2711)8646816,Web:www.lafarge.co.za
0861 gYPSUM (497786)