case narrative - ida ore
TRANSCRIPT
Client: Ida Ore Zeolite, LLC Lab Order: 17061608Project: Zeolite Mix Samples Report Date: 6/30/2017
This data package consists of the following:
Case Narrative - 1 Page
Sample Analysis Reports - 5 Pages
Chain of Custody and Sample Log-in Report - 2 Pages
CASE NARRATIVE
Some parameters were sub-contracted to Pace Analytical for analysis.
Page 1 of 8
Lab ID: 17061608-01
Customer Sample ID: Horizontal Brine-Zeo Mix
Matrix: Soil
Notes:
Customer Name: Ida-Ore Zeolite, LLC
Project ID: Zeolite Mix
Order ID: 17061608
Report Date: 6/30/2017
LABORATORY ANALYTICAL REPORT
Analyses Method Analysis Date/Time AnalystResult Units RL Qual.
Collection 6/13/2017
Received: 6/16/2017 2:05 PM
Date Time
Organic Compounds
Benzene 290 ug/Kg 200 EPA 8021 B 6/22/2017 TMC1:59
4-Bromofluorobenzene (PID)Surr: 99.4 % 70-130 EPA 8021 B
Toluene 530 ug/Kg 200 EPA 8021 B 6/22/2017 TMC1:59
4-Bromofluorobenzene (PID)Surr: 99.4 % 70-130 EPA 8021 B
Ethyl Benzene 540 ug/Kg 200 EPA 8021 B 6/22/2017 TMC1:59
4-Bromofluorobenzene (PID)Surr: 99.4 % 70-130 EPA 8021 B
m,p-Xylene 18000 ug/Kg 400 EPA 8021 B 6/22/2017 TMC1:59
4-Bromofluorobenzene (PID)Surr: 99.4 % 70-130 EPA 8021 B
o Xylene 7400 ug/Kg 200 EPA 8021 B 6/22/2017 TMC1:59
4-Bromofluorobenzene (PID)Surr: 99.4 % 70-130 EPA 8021 B
Gasoline Range Organics (GRO) 555900 ug/Kg 22000 EPA 8015 D 6/22/2017 TMC1:59
4-Bromofluorobenzene (FID)Surr: 99.2 % 70-130 EPA 8015 D
Diesel Range Organics (DRO) 2494 mg/kg 500 EPA 8015 D 6/22/2017 TMC0:40
o-TerphenylSurr: 93.8 % 70-130 EPA 8015 D
Total Petroleum Hydrocarbons 3050 mg/kg 5.5 EPA 8015 D 6/28/2017 JS16:14
Definitions:
ND-Not Detected at the reporting limit
RL-Analyte Reporting Limit
H-Holding times for preparation or analysis exceeded
S-Spike Recovery outside accepted recovery limits
M-Matrix Effect
J-Analyte detected below quantitation limits
D-Diluted out of recovery limits
L-Analyzed by a contract laboratory
Documentation will be kept for five (5) years.
Page 2 of 8
Laboratory Analytical ReportCustomer Name: Ida-Ore Zeolite, LLC
Project ID: Zeolite Mix
Order ID: 17061608
Report Date: 6/30/2017
Analyses Method AnalystResult Units RL
Lab Sample ID: 17061608-01
Collection: 6/13/2017
Received: 6/16/2017
Customer Sample ID: Horizontal Brine-Zeo Mix
Matrix: Soil
Qual.
2:05 PM
Date Time
Notes:
Arsenic EPA 6010 C MMCND mg/kg 0.05
Barium EPA 6010 C MMC1080 mg/kg 5
Cadmium EPA 6010 C MMCND mg/kg 0.05
Chloride EPA 300.0 TMC681.4 mg/kg 1
Chromium MMCND mg/kg 0.05
Conductivity measured JS2400 uS/cm 1
Lead MMCND mg/kg 0.05
Mercury CL0.042 mg/kg 0.029 L
Selenium MMCND mg/kg 0.05
Silver
EPA 6010 C
WREP-125: S-1.20
EPA 6010 C
EPA 7471
EPA 6010 C
EPA 6010 C MMCND mg/kg 0.05
Analysis Date/Time
6/26/2017 5:04:15 PM
6/26/2017 5:04:15 PM
6/26/2017 5:04:15 PM
6/19/2017 8:32:00 PM
6/26/2017 5:04:15 PM
6/20/2017 1:30:00 PM
6/26/2017 5:04:15 PM
6/25/2017 4:24:00 PM
6/26/2017 5:04:15 PM
6/26/2017 5:04:15 PM
Definitions:
ND-Not Detected at the reporting limit
RL-Analyte Reporting Limit
H-Holding times for preparation or analysis exceeded
S-Spike Recovery outside accepted recovery limits
M-Matrix Effect
J-Analyte detected below quantitation limits
D-Diluted out of recovery limits
L-Analyzed by a contract laboratory
Documentation will be kept for five (5) years.
29 Country Acres Rd., Riverton, WY 82501 • E-mail: [email protected] • www.Precision-Labs.com
Page 3 of 8
Lab ID: 17061608-02
Customer Sample ID: Horizontal Brine-Zeo Mix
Matrix: Leachate
Notes:
Customer Name: Ida-Ore Zeolite, LLC
Project ID: Zeolite Mix
Order ID: 17061608
Report Date: 6/30/2017
LABORATORY ANALYTICAL REPORT
Analyses Method Analysis Date/Time AnalystResult Units RL Qual.
Collection 6/13/2017
Received: 6/16/2017 2:05 PM
Date Time
Organic Compounds
Oil & Grease (HEM) by WY Leachate 12.8 mg/L 1 EPA 1664 A 6/26/2017 TMC12:30
Definitions:
ND-Not Detected at the reporting limit
RL-Analyte Reporting Limit
H-Holding times for preparation or analysis exceeded
S-Spike Recovery outside accepted recovery limits
M-Matrix Effect
J-Analyte detected below quantitation limits
D-Diluted out of recovery limits
L-Analyzed by a contract laboratory
Documentation will be kept for five (5) years.
Page 4 of 8
Lab ID: 17061608-03
Customer Sample ID: Horizontal Brine
Matrix: Aqueous
Notes:
Customer Name: Ida-Ore Zeolite, LLC
Project ID: Zeolite Mix
Order ID: 17061608
Report Date: 6/30/2017
LABORATORY ANALYTICAL REPORT
Analyses Method Analysis Date/Time AnalystResult Units RL Qual.
Collection 6/13/2017
Received: 6/16/2017 2:05 PM
Date Time
Organic Compounds
Benzene 664.0 ug/L 100 EPA 8021 B 6/22/2017 TMC2:28
4-BromofluorobenzeneSurr: 91.5 % 70-130 EPA 8021 B
Toluene 1260 ug/L 100 EPA 8021 B 6/22/2017 TMC2:28
4-BromofluorobenzeneSurr: 91.5 % 70-130 EPA 8021 B
Ethyl Benzene 1043 ug/L 100 EPA 8021 B 6/22/2017 TMC2:28
4-BromofluorobenzeneSurr: 91.5 % 70-130 EPA 8021 B
m,p-Xylene 6278 ug/L 200 EPA 8021 B 6/22/2017 TMC2:28
4-BromofluorobenzeneSurr: 91.5 % 70-130 EPA 8021 B
o Xylene 1728 ug/L 100 EPA 8021 B 6/22/2017 TMC2:28
4-BromofluorobenzeneSurr: 91.5 % 70-130 EPA 8021 B
Gasoline Range Organics (GRO) 86130 ug/L 11000 EPA 8015 D 6/22/2017 TMC2:28
4-Bromofluorobenzene (FID)Surr: 99.7 % 70-130 EPA 8015 D
Diesel Range Organics (DRO) 26640 mg/L 4100 EPA 8015 D 6/22/2017 TMC3:38
o-TerphenylSurr: 0.0 % 70-130 EPA 8015 D
Oil & Grease (HEM) 13700 mg/L 1 EPA 1664 A 6/26/2017 TMC12:30
TPH as DRO + GRO 26730 mg/L 0.1 Calculation 6/28/2017 JS16:14
Definitions:
ND-Not Detected at the reporting limit
RL-Analyte Reporting Limit
H-Holding times for preparation or analysis exceeded
S-Spike Recovery outside accepted recovery limits
M-Matrix Effect
J-Analyte detected below quantitation limits
D-Diluted out of recovery limits
L-Analyzed by a contract laboratory
Documentation will be kept for five (5) years.
Page 5 of 8
Laboratory Analytical ReportCustomer Name: Ida-Ore Zeolite, LLC
Project ID: Zeolite Mix
Order ID: 17061608
Report Date: 6/30/2017
Analyses Method Analysis Date/Time AnalystResult Units RL
Lab Sample ID: 17061608-03
Collection: 6/13/2017
Received: 6/16/2017
Customer Sample ID: Horizontal Brine
Matrix: Aqueous
Qual.
2:05 PM
Date Time
Notes:
Arsenic EPA 200.7 MMCND mg/L 0.05 6/28/2017 12:07:40 PM
Barium EPA 200.7 MMC8.99 mg/L 0.05 6/28/2017 12:07:40 PM
Cadmium EPA 200.7 MMCND mg/L 0.05 6/28/2017 12:07:40 PM
Chloride EPA 300.0 TMC2235 mg/L 100 6/19/2017 7:57:00 PM
Chromium EPA 200.7 MMCND mg/L 0.05 6/28/2017 12:07:40 PM
Conductivity SM 2510 B JS13900 µS/cm 5 6/20/2017 1:30:00 PM
Lead EPA 200.7 MMCND mg/L 0.05
Mercury CLND ug/L 0.20 L
Selenium MMCND mg/L 0.05
Silver MMC0.57 mg/L 0.05
TPH as DRO + GRO
EPA 245.1
EPA 200.7
EPA 200.7
Calculation JS26730 mg/L 0.1
6/28/2017 12:07:40 PM
6/26/2017 7:20:00 PM
6/28/2017 12:07:40 PM
6/28/2017 12:07:40 PM
6/28/2017 4:14:12 PM
Definitions:
ND-Not Detected at the reporting limit
RL-Analyte Reporting Limit
H-Holding times for preparation or analysis exceeded
S-Spike Recovery outside accepted recovery limits
M-Matrix Effect
J-Analyte detected below quantitation limits
D-Diluted out of recovery limits
L-Analyzed by a contract laboratory
Documentation will be kept for five (5) years.
29 Country Acres Rd., Riverton, WY 82501 • E-mail: [email protected] • www.Precision-Labs.com
Page 6 of 8
Login Report
Order ID: 17061608Customer Name: Ida-Ore Zeolite, LLC
Project ID: Zeolite Mix
Comment:
Order Date: 6/16/2017
SAMPLE CONDITION RECORD
Number of cooler/packages received: 1
Number of bottles received: 16
Were the samples received intact? (no broken bottles, leaks, etc.) Yes
Were the samples received with custody seals? No
Were custody seals intact? N/A
Did signature match? N/A
Is the COC properly completed, legible, and signed? Yes
Were all samples received accounted for on the COC? Yes
Were all requested analyses understood and appropriate? Yes
Did the bottle labels correspond with the COC information? Yes
Were Samples collected in proper containers? Yes
Were the Temp and Pressure recorded for cylinders? N/A
Were all containers properly preserved, and pH checked - should be <=2? Yes
Do VOA vials have <6mm headspace? No
Was a trip blank present? No
Were all analyses within holding time at time of receipt? Yes
Have rush or project due dates been checked and accepted? Yes
Login verification: Client Name: Yes
Login verification: Project Name: Yes
Login Verification: Matrix: Yes
Sample/Cooler Temperature(s): 21.3
Were cylinder valves leaking? N/A
Were pressurized liquid samples collected at a rate of <50 ml/min? N/A
Page 7 of 8
Page 8 of 8