Tape to protect while handling. HDX Splice Module Cat. Nos. SPLCH, SPMPH INSTALLATION INSTRUCTIONS ENGLISH PK-A3258-10-00-0A PK-A3258-10-00-0A WARNINGS READ AND UNDERSTAND ALL INSTRUCTIONS. Follow all warnings and instructions marked on the product. DISCONNECTED OPTICAL COMPONENTS MAY EMIT INVISIBLE OPTICAL RADIATION THAT CAN DAMAGE YOUR EYES. TO AVOID SERIOUS INJURY, never look directly into an optical component that may have a laser coupled to it. If accidental exposure to laser radiation is suspected, consult a physician for an eye examination. CAUTIONS TO AVOID INJURY, wearing safety glasses during installation of this device is recommended. Although standard safety glasses provide no protection from potential optical radiation, they offer protection from accidental airborne hardware and cleaning solvents. Isopropyl alcohol is flammable and can cause eye irritation on contact. If eye contact occurs, flush with water for at least 15 minutes. In case of ingestion, consult a physician. Use only in well ventilated areas. Fiber optic cable is sensitive to excessive pulling, bending and crushing forces. Do not bend the cable less than recommended bend radius. Do not use more pulling force than specified. Do not kink or crush the cable. Includes: 1. Splice Module Base (LC or MTP) 2. Splice Module Cover 3. Convertible splice sleeve holder 4. Splice Sleeve Holder retention tabs 5. Single and Ribbon splice sleeves 6. Cable Management tab 7. Cover tab 8. Module Release button 9. Fiber Optic Pigtail 10. Nylon Tie Wraps 11. Mesh Tubing Installation 1. Open module. Optional Accessories: • HDXAD-ACC - HDX to SDX Adapter Bracket • 5FUHD-BLK - HDX Adapter Plate Blank FSSSD-040 - Single Fiber Splice Sleeves, 40mm (50 pack) FSSRB-040 - Ribbon Fiber Splice Sleeves, 40 mm (25 pack) You Will Need: Single and/or mass fusion splicer with compatible fiber holders • Precision cleaver • When working with outside plant or armored cables: - safety blade/utility knife - armor jacket removing tool - gel remover • Fiber termination kit: - aramid yarn scissors - lint free wipes - fiber cleaning solution or 95% or better isopropyl alcohol - jacket removing tool - fiber stripping tool - fiber waste container push and lift Mounts in these devices: • UHDX Rack Mount Enclosures • UHDX Rack Mount Panels • HDX Frame • SDX Enclosures with HDX to SDX Adapter Brackets 2. Prepare fiber. Determine termination location. Depending on cable construction, breakout and/or furcation may be required. NOTE: Incoming cable opening is 7.6 mm. Evaluate incoming fiber to verify correct sizing. High count cable: overall fiber cabling larger than the following requires breakout prior to install: >36 fiber for MTP splice modules >12 fiber for LC splice modules Tight buffered cable: 12 fiber cable can be routed directly to the splice module. Overall fiber cabling larger than 7.6 mm, secure the cable to the enclosure cable management tie down points according to the device instructions, remove the outer jacket after the tie down point and utilize the mesh sleeve provided in this accessory kit to protect and route the individual fibers to the module. Loose tube cable: if overall fiber cabling larger than 7.6 mm and correctly sub-unitized under cable jacket, secure cable to tie down points, remove jacket after tie down points and route sub-unit tubes to each module. 3. Route fiber. a. Remove at least 35 mm of outer cable jacket. NOTE: Do not store excessive fiber slack within the module housing. Achieve minimal slack by routing fiber(s) in the widest path available under the wire management tabs as shown in the routing diagrams. All other required slack storage should be performed in the fiber enclosure and/or available pathway outside the enclosure. b. Feed incoming cable(s) through the rear opening and secure through the tie wrap slots and over the cable jacket with nylon tie. NOTE: Tie wrap will be removed prior to termination. 4. Prepare pigtail assembly (single fiber [Option A] or mass fusion [Option B]) NOTE: Cut pigtail after making Zero Mark. Option B 250 μm loose tube fiber Tape to protect while handling. 250 μm ribbonized fiber 1 12 1 12 LEG 1 Option A LEG 12 900 μm buffered tubing (VIOLET is shortest) 250 μm loose tube fiber Mark all fiber strands at the ZERO MARK indicator in the module base after routing. Cut before ribbon for loose tube splicing. ZERO MARK WHEN TERMINATING LOOSE TUBE FIBER ZERO MARK WHEN TERMINATING RIBBON FIBER ZERO MARK WHEN TERMINATING RIBBON FIBER 250 μm ribbonized fiber 1 12 5. Route pigtail fibers. a. Route pigtail fibers counter clockwise. • When splicing single fiber, route the fibers one full loop and mark at Zero Mark. • When performing mass fusion splices, route the fiber two full loops and mark at Zero Mark. b. Remove pigtail fibers from module, leaving connectors mated into adapters. 6. Route trunk fibers. a. Route trunk fibers clockwise. b. Mark all fibers at Zero Mark. c. Remove all fibers from module. MARK FIBER FOR SPLICING MARK FIBER FOR SPLICING PIGTAIL FIBER TRUNK FIBER Incoming Trunk cable OR Single Splice sleeves x 13 in LC kits Ribbon Splice sleeves x 1 in LC kits x 3 in MTP kits x 3 x 3 11 10 3 2 1 1 7 5 8 8 6 6 4 4 9 9 LC MTP Fiber Pigtail (Leg 1 of 12) Approx. 16” (Full loop 25”) (Leg 1- BLUE of 12 shown) YELLOW 9 VIOLET 10 ROSE 11 AQUA 12 SLATE 5 WHITE 6 RED 7 BLACK 8 BLUE 1 ORANGE 2 GREEN 3 BROWN 4 A B A B A B A B A B A B WEB VERSION

Upload: others

Post on 20-Mar-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Cat. Nos. SPLCH, SPMPH · Tape to protect while handling. HDX Splice Module Cat. Nos. SPLCH, SPMPH INSTALLATION INSTRUCTIONS ENGLISH PK-A3258-10-00-0A PK-A3258-10-00-0A WARNINGS

Tape to protect while

handling.

HDX Splice ModuleCat. Nos. SPLCH, SPMPH

INSTALLATION INSTRUCTIONS ENGLISH

PK-A3258-10-00-0A

PK-A3258-10-00-0A

WARNINGS

• READ AND UNDERSTAND ALL INSTRUCTIONS. Follow all warnings and instructions marked on the product.

• DISCONNECTED OPTICAL COMPONENTS MAY EMIT INVISIBLE OPTICAL RADIATION THAT CAN DAMAGE YOUR EYES. TO AVOID SERIOUS INJURY, never look directly into an optical component that may have a laser coupled to it. If accidental exposure to laser radiation is suspected, consult a physician for an eye examination.

CAUTIONS

• TO AVOID INJURY, wearing safety glasses during installation of this device is recommended. Although standard safety glasses provide no protection from potential optical radiation, they offer protection from accidental airborne hardware and cleaning solvents.

• Isopropyl alcohol is flammable and can cause eye irritation on contact. If eye contact occurs, flush with water for at least 15 minutes. In case of ingestion, consult a physician. Use only in well ventilated areas.

• Fiber optic cable is sensitive to excessive pulling, bending and crushing forces. Do not bend the cable less than recommended bend radius. Do not use more pulling force than specified. Do not kink or crush the cable.

Includes: 1. Splice Module Base (LC or MTP) 2. Splice Module Cover 3. Convertible splice sleeve holder 4. Splice Sleeve Holder retention tabs 5. Single and Ribbon splice sleeves 6. Cable Management tab 7. Cover tab 8. Module Release button 9. Fiber Optic Pigtail 10. Nylon Tie Wraps 11. Mesh Tubing

Installation 1. Open module.

Optional Accessories:• HDXAD-ACC - HDX to SDX Adapter Bracket• 5FUHD-BLK - HDX Adapter Plate Blank• FSSSD-040 - Single Fiber Splice Sleeves,

40mm (50 pack)• FSSRB-040 - Ribbon Fiber Splice Sleeves,

40 mm (25 pack)

You Will Need:• Single and/or mass fusion splicer with compatible

fiber holders• Precision cleaver• When working with outside plant or armored cables: - safety blade/utility knife - armor jacket removing tool - gel remover

• Fiber termination kit: - aramid yarn scissors - lint free wipes - fiber cleaning solution or 95%

or better isopropyl alcohol - jacket removing tool - fiber stripping tool - fiber waste container

push and lift

Mounts in these devices:• UHDX Rack Mount Enclosures• UHDX Rack Mount Panels• HDX Frame• SDX Enclosures with HDX to SDX Adapter Brackets

2. Prepare fiber.

Determine termination location. Depending on cable construction, breakout and/or furcation may be required.

NOTE: Incoming cable opening is 7.6 mm. Evaluate incoming fiber to verify correct sizing.

• High count cable: overall fiber cabling larger than the following requires breakout prior to install:

>36 fiber for MTP splice modules

>12 fiber for LC splice modules

• Tight buffered cable: 12 fiber cable can be routed directly to the splice module. Overall fiber cabling larger than 7.6 mm, secure the cable to the enclosure cable management tie down points according to the device instructions, remove the outer jacket after the tie down point and utilize the mesh sleeve provided in this accessory kit to protect and route the individual fibers to the module.

• Loose tube cable: if overall fiber cabling larger than 7.6 mm and correctly sub-unitized under cable jacket, secure cable to tie down points, remove jacket after tie down points and route sub-unit tubes to each module.

3. Route fiber.

a. Remove at least 35 mm of outer cable jacket.

NOTE: Do not store excessive fiber slack within the module housing. Achieve minimal slack by routing fiber(s) in the widest path available under the wire management tabs as shown in the routing diagrams. All other required slack storage should be performed in the fiber enclosure and/or available pathway outside the enclosure.

b. Feed incoming cable(s) through the rear opening and secure through the tie wrap slots and over the cable jacket with nylon tie.

NOTE: Tie wrap will be removed prior to termination.

4. Prepare pigtail assembly (single fiber [Option A] or mass fusion [Option B])

NOTE: Cut pigtail after making Zero Mark.

Option B

250 μm loose tube fiber

Tape to protect while

handling.

250 μm ribbonized fiber

1

12

1

12

LEG 1

Option A

LEG 12 900 μm buffered tubing (VIOLET is shortest)

250 μm loose tube fiber

Mark all fiber strands at the ZERO MARK indicator in the

module base after routing.

Cut before ribbon for loose tube splicing.

ZERO MARKWHEN TERMINATING LOOSE TUBE FIBER

ZERO MARKWHEN TERMINATING

RIBBON FIBER

ZERO MARKWHEN TERMINATING

RIBBON FIBER

250 μm ribbonized fiber1

12

5. Route pigtail fibers.

a. Route pigtail fibers counter clockwise.

• When splicing single fiber, route the fibers one full loop and mark at Zero Mark.

• When performing mass fusion splices, route the fiber two full loops and mark at Zero Mark.

b. Remove pigtail fibers from module, leaving connectors mated into adapters.

6. Route trunk fibers.

a. Route trunk fibers clockwise.

b. Mark all fibers at Zero Mark.

c. Remove all fibers from module.

MARK FIBER FOR SPLICING

MARK FIBER FOR SPLICING

PIGTAIL FIBER TRUNK FIBER

Incoming Trunk cable

OR

Single Splice sleevesx 13 in LC kits

Ribbon Splice sleevesx 1 in LC kitsx 3 in MTP kits

x 3

x 3

11

103

2

11

7

5

88

66

44

9

9

LC MTP

Fiber Pigtail(Leg 1 of 12)

Approx. 16” (Full loop 25”) (Leg 1- BLUE of 12 shown)

YELLOW 9VIOLET 10

ROSE 11AQUA 12

SLATE 5WHITE 6

RED 7BLACK 8

BLUE 1ORANGE 2

GREEN 3BROWN 4

ABABABABABAB

WE

B V

ER

SIO

N

Page 2: Cat. Nos. SPLCH, SPMPH · Tape to protect while handling. HDX Splice Module Cat. Nos. SPLCH, SPMPH INSTALLATION INSTRUCTIONS ENGLISH PK-A3258-10-00-0A PK-A3258-10-00-0A WARNINGS

PK-A3258-10-00-0A© 2018 Leviton Mfg. Co., Inc. For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.leviton.com

LIMITED 1 YEAR WARRANTY AND EXCLUSIONSLeviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for one year from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option. For details visit www.leviton.com or call 1-800-824-3005. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to one year. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

FOR CANADA ONLYFor warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada Ltd to the attention of the Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.

INDUSTRY CANADA COMPLIANCE STATEMENT:

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. IMPORTANT! Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This Class A digital apparatus complies with Canadian CAN ICES-3(A)/NMB-3(A).

TRADEMARK DISCLAIMER: Use herein of third party trademarks, service marks, trade names, brand names and/or product names are for informational purposes only, are/may be the trademarks of their respective owners; such use is

7. Terminate.

NOTE: Cleave lengths and termination steps can vary. Consult your splicer instructions.

a. Install splice sleeves

b. Shorten each fiber to 35 mm past Zero Mark using guide.

c. Strip.

d. Perform fusion splicing per manufacturer's instructions

e. Place fibers in splice sleeve holder after termination as shown by termination type.

8. Route assembly into module (single fiber or mass fusion).

a. Feed fibers through channel shown.

b. Rotate module base clockwise as you place fibers under tabs.

c. Position sleeve holder and snap into place, positioning the last 250 um of fiber under the LC connectors

d. Continue rotating module clockwise, routing trunk fibers under tabs as you go, with final length of fiber in outermost channel.

e. Secure trunk jacket at entrance, tie with wraps.

11. Mount module in enclosure.

All modules install through front of enclosure. If using an enclosure or HDX patch deck with sliding trays, individual trays can be removed for ease of use.

a. Place module in guide rails of enclosure.

b. Slide module toward back of enclosure until latch engages.

12. To remove module.

a. Gently press button.

b. Remove module.

Label Printing Organization by Fiber Adapter Type

HDXSplice Module

Per ColumnNumber Scheme

Port Spacing No. of Ports

Quad LC (duplexed) 0.6 6 1 2 3 4 5 6

Quad LC (by fiber) 0.6 12 1-2/3-4 5-6/7-8 9-10/11-12

MTP (3 port) 1.20 3 1 Space 2 Space 3

9. Replace lid.

NOTE: To avoid damaging fibers, verify all fiber optic cabling is correctly routed within the module base under the cable management tabs prior to installing and securing the lid.

2

1

10. Label module.

Affix labels as shown.

NOTE: Make sure the label surface area is free of dirt, oil and debris. When wiping down surface area, use isopropyl alcohol or a simple soap and water solution.

a.

b.

PLACE FIBER HERE TO MARK

end of strippedfiber 35mm

end of buffered fiber (zero mark)

REMOVE ACRYLATE

TRUNK LEGS

PIGTAILS

1 2 3 4 5 6 7 8 9 10 11 12

TRUNK LEGS

PIGTAILS

1 2 3

SINGLE SPLICEHOLDERS NOT USED

RIBBON SPLICING

TRUNK LEGS

PIGTAILS

1 2 3 4 5 6 7 8 9 10 11 12

TOP ROW – EVEN FIBERSBOTTOM ROW – ODD FIBERS

RIBBONHOLDERS

NOT USED 1

2 4

3 5

6 8

7

10

9

12

11

SINGLE SPLICING

SIDE VIEW

Splice Sleeve Holder with Spliced Fiber (in 40 mm sleeve)

SIDE VIEW

Splice Sleeve Holder with Ribbon Splicing

Single Fusion Splicing for LC pigtails Mass Fusion Splicing for LC pigtails Mass Fusion Splicing for MTP pigtails

PIG

TA

ILS

12

34

56

78

910

1112

12

34

56

78

910

1112

WE

B V

ER

SIO

N