catalogo- ge752 . curvas.pdf
TRANSCRIPT
-
8/10/2019 catalogo- ge752 . curvas.pdf
1/61
TOP DRIVE DRILLING SYSTEM
PRODUCT INFORMATION
COPYRIGHT 2006CANRIG DRILLING TECHNOLOGY LTD.ALL RIGHTS RESERVED
This Top Drive System is protected by one or more of the following US patents and foreign counterparts:
US 4,478,291 * US 4,951,709 * US 5,251,709 * US 6,024,181 and other patents pending.
-
8/10/2019 catalogo- ge752 . curvas.pdf
2/61
Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any formor by any means, electronic or mechanical, for any purpose, without the express written permission of Canrig Drilling Technology Ltd.
Printed in the United States of America.
-
8/10/2019 catalogo- ge752 . curvas.pdf
3/61
PRODUCT INFORMATIONTOP DRIVE DRILLING SYSTEMS
Canrig Drilling Technology Ltd.14703 FM 1488
Magnolia, TX 77354
Main Office: 281-259-8887
Main Fax: 281-259-8158
Email: [email protected]
Web: www.canrig.com
Canrig Drilling Technology Ltd offers a complete range of electric Top Drivemodels with hoisting capacity from 175 to 1250 tons. In our DC units thehorsepower for each model increases as the hoisting capacity is increased. Thegear ratio for each model can be altered to provide varied torque to speed ratios.
Canrigs AC top drives range in hoisting capacity from 175 to 1250 tons. The use ofAC technology produces improved performance resulting in a fatter torque curve.
A brief description of our models is as follows:
Model Motor Hoisting CapacityTons
NominalHP
4017AC AC 175 400
6027E DC - GE761 275 600
6027AC AC - GE B-20 275 600
8035E DC - GE752 350 1130
8050AC AC - GE B-20 500 800
1050E DC - GE752 500 11301175E DC - GE752 750 1130
1250AC AC - GE B-20 500 1150
1275AC AC - GE B-20 750 1150
24125AC AC - GE B-20 1250 2300
1
mailto:[email protected]:[email protected] -
8/10/2019 catalogo- ge752 . curvas.pdf
4/61
PRODUCT INFORMATIONFEATURES AND BENEFITS
Features and Benefits of a Canrig Top Drive Dril ling System
1. Integral Swivel
Eliminates fatigue failures associated with threaded connections.2. Hydraulic Torque Boost
Continuous rotation of up to 5 RPM
Precise directional control3. Industry Exclusive Floating Quill for Soft Stabbing and Thread Advance
Compensation
Prevent thread damage during make-up and break-out.4. Polymer Slide Guide Runners
Fewer components, significantly reducing the risk of falling parts. Improved load distribution
5. Counter Balance Feature
Duplicates the dampening effect of the spring on a conventional hook.6. Dual Lower Well Control Valves, One Manual and One Remote Actuated
Provides optimal well control7. Remote Actuated Upper Well Control Valve
Improves well control options and acts as mud saver valve.8. Local or Remote Blower Option
Operator selected-based on hazardous area requirements.9. Wireline Guide System
Enables efficient wireline entry.10. Direct Connection to Rigs Traveling Block
Reduces system height and weight by eliminating the block hook.11. Disc Brake
Allows infinite positions for directional orientation.
Provides inertia braking.12. AC or DC Electric Drive Motor
Allows operator to select configuration best suited to the application.13. Soft Torque Vibration Control System Available
Reduces slip-stick thus improving drilling efficiency.14. Remote Control of Pipe Handler Orientation and a Lock
Permits driller to maximize efficiency of pipe handling operations.15. By-Directional Link Tilt Function
Permits overdrill thus allowing connection to be made with bit offbottom.
16. Load Path Integrity No Thread Connections in the Load Path
Eliminates fatigue type failures associated with threaded connections.
2
-
8/10/2019 catalogo- ge752 . curvas.pdf
5/61
PRODUCT INFORMATIONFEATURES AND BENEFITS
Motor
Torque Guide
Traveling Block(by customer)
Dependentonlengthof
Air Cooling System Intake
Local Blower
Custom Block Interface
Rotary Hose Connection
Motor Guard
Gear Case
Torque Boost
Link Support
Rotary Manifold
Back-upW
renchTravel
variesbymodel.
Appro
x.
2feet
Bi-directional Link Tilt
Manual Lower Well Control Valve
Elevator Link8 foot length shown
Elevator
Top Drive Motor
3
-
8/10/2019 catalogo- ge752 . curvas.pdf
6/61
PRODUCT INFORMATIONTOP DRIVE UNIT
The Top Drive Unitconsists of the following in either a fixed or portable system:
1. Top drive housing with mounting lugs.2. Upper support links and bail or block adapter for hoisting interface to the
customers travelling block (unspecified) with the hook removed.3. Adjustable top drive guide runners.4. Drive unit including spindle, bearings, and gearing. Standard gear ratios are
as follows:
Model 4017AC 12.262:1
Model 6027E 9.387:1*
Model 6027AC 9.387:1
Model 8035E 5.000:1 Model 8050AC 7.120:1
Model 1050E 5.000:1*
Model 1175E 7.120:1*
Model 12XXAC 6.808:1
Model 24125AC 6.893:1**Other gear ratios are optionally available.
5. DC or AC drive motor (model differences as in the table on page 1)6. Floating quill with 8 inches free float.7. Brake - hydraulic caliper disk type.8. Hydraulic torque boost
9. Remotely rotatable and lockable pipe handling assembly including: Elevator link support
Link support counterbalance system
Bi-directional link tilt assembly
Back-up wrench with one set of die blocks
Link-tilt clamps for the following elevator link sizes:
Model 4017AC 250 tonModel 6027E 250 and 350 tonModel 6027AC 250 and 350 tonModel 8035E 250, 350 and 500 tonModel 8050AC 350 and 500 ton
Model 1050E 350 and 500 tonModel 1175E 350, 500 and 750 tonModel 1250AC 350 and 500 tonModel 1275AC 350, 500 and 750 ton
Pipe stabbing guide bell10. Washpipe assembly11. Mud gooseneck, 4 inch nominal diameter, with a 2 inch NPTF top port for
wireline operations (a 3 inch vertical through-bore with a Bowen union isoptional).
4
-
8/10/2019 catalogo- ge752 . curvas.pdf
7/61
PRODUCT INFORMATIONTOP DRIVE UNIT
12. Upper mud saver valve available with a hydraulic remote actuator.
13. Lubrication circulating system including the following: Suction strainer.
Pump and electric motor.
Filter, 25 micron absolute.
Cooler with and electrically driven fan.14. Hydraulic valves (solenoid operated) for auxiliary functions.15. Hydraulic piping, hose and fittings on the top drive unit. Diagnostic pressure
test points are provided for all functions. Hose and tube fittings are the"ORS" type for premium sealing performance.
16. Instrumentation gauges and sensors including the following:
Hydraulic pressure and return gauges.
Lubrication pressure gauge. Lubrication temperature gauge.
Lubrication alarm pressure switch.
Lubrication alarm temperature switch.
Air cooling alarm pressure switch.
RPM sensor.17. Service connections for the kelly hose, hydraulics, DC power, electrical
controls, and cooling air.18. Lower well control valve (LWCV), manual operation, connections to match
drill pipe, 10 000 psi WP is standard, with extended pin end for recutallowance. Quantity 2 valves furnished to allow for one running and one
being re-cut.19. Crossover sub between the quill and the LWCV20. High-torque tool joint clamp for the LWCV connections.21. Prepared, primed and painted (safety yellow).22. Parts, maintenance and operating manuals.23. Conformance to API Specifications 7, 8C, RP14F, and RP500B.24. Electrical equipment complies with the requirements of CSA and API 500B.25. Adapter for connection of the mast sling line equalizer to the block adapter.26. Drill collar handling subs for drilling and reaming drill collars, quantity 2 for
up to 7 inch collars and quantity 2 for up to 9 inch collars.27. Top drive tool kit.
5
-
8/10/2019 catalogo- ge752 . curvas.pdf
8/61
PRODUCT INFORMATIONDC TOP DRIVE MODEL 6027E
MODEL 6027E TOP DRIVEGENERAL ARRANGEMENT
6
-
8/10/2019 catalogo- ge752 . curvas.pdf
9/61
PRODUCT INFORMATIONDC TOP DRIVE MODEL 6027E
Specifications
Top Drive Model 6027EStatic Hoist Rating
Elevator Load Path 275 Tons 249 Tonnes
Quill Load Path 275 Tons 249 Tonnes
Electric Motor GE 761 Series GE 761 Shunt
Gear Ratio 9.387:1 7.726:1 9.387:1 7.726:1
Continuous Torque Rating 24 000 ft-lb(32 500 Nm)@ 130 RPM
19 700 ft-lb(22 700 Nm)@160 RBM
21 000 ft-lb(28 500 Nm)@ 150 RPM
19 800 ft-lb(26 800 Nm)@ 182 RPM
Intermittent Torque Rating 30 000 ft-lb(40 700 Nm)@ 130 RPM
24 600 l-lb(33 400 Nm)@ 160 RPM
24 200 ft-lb(32 800 Nm)@ 150 RPM
19 900 ft-lb(27 000 Nm)@ 182 RPM
Maximum Speed Rating 15 200 ft-lb(20 600 Nm)@ 205 RPM
13 100 ft-lb(17 800 Nm)@240 RPM
13 300 ft-lb(18 000 Nm)@ 200 RPM
10 900 ft-lb(14 800 Nm)@ 235 RPM
Brake Capacity 20 000ft-lb(27 400 Nm)
16 600 ft-lb(19 000 Nm)
20 000 ft-lb(27 400 Nm)
16 600 ft-lb(22 500 Nm)
Maximum Connection B /O Torque 60 000 ft-lb(81 300 Nm)
60 000 ft-lb(81 300 Nm)
60 000 ft-lb(81 300 Nm)
60 000 ft-lb(81 300 Nm)
(Make-Up Limit i s operator adjustable)
Torque Boost TorqueMake-Up 24 000 ft-lb
(32 500 Nm)
24 000 ft-lb
(32 500 Nm))
24 000 ft-lb
(32 500 Nm)
24 000 ft-lb
(32 500 Nm)Break Out 37 500 ft-lb(50 800 Nm)
37 500 ft-lb(50 800 Nm)
37 500 ft-lb(50 800 Nm)
37 500 ft-lb(50 800 Nm)
Pipe Handler Orientation Unlimited, remote controlled
Pipe Handler Lock 33 positions, remote controlled
Back-up Wrench Gripper 5.75 to 9.0 inches.
Diameter Range 3.75 to 7.0 inches with alternate die blocks
Back-Up Wrench Maximum Travel 26.75 inches 68 cm
Quill Connection NC50
Water Course Diameter 2.6 inches 6.6 cm
Circulating Pressure Rating - Standard 5 000 PSI
Circulating Pressure Rating - Optional 7 500 PSI
Floating Quill Travel 7.9 inches 20 cm
Link Counterbalance Travel 7.0 inches 18 cm
7
-
8/10/2019 catalogo- ge752 . curvas.pdf
10/61
PRODUCT INFORMATIONDC TOP DRIVE MODEL 6027E
Cooling System STANDARD: Local Blower
7.5 HP, 1 680 scfm flow (6 KW, 50 m3/min) flow
Lubrication System 2 HP, 4 GPM flow 1.5 KW, 15 l/min flow
Hydraulic Requirement 12 GPM flow 45 l/min flow
2 350 PSI 16 200 KPa
Pressure compensated control
(see HPU Specifications)
Electrical Power GE 761 Series GE 761 Shunt
Field Supply N/A 39.2, 28.0, 19.3 Amps
Max. continuous armature current 630 Amps 630 Amps
Max. intermittent armature current 750 Amps 750 Amps
Max. armature voltage 750 VDC 750 VDC
Weight (without b locks) 18 000 lb(8 200 Kg)
18 000 lb(8 200 Kg)
8
-
8/10/2019 catalogo- ge752 . curvas.pdf
11/61
PRODUCT INFORMATIONDC TOP DRIVE MODEL 6027E
MODEL 6027E-939 STANDARD GEAR RATIO TORQUE CURVE
SERIES
0
5000
10000
15000
20000
25000
30000
0 50 100 150 200 250
TO
RQ
UE
Continuous
Curves based on GE Model 761, DC Drilling Motor (600 HP) Series 9.387:1 Gear Ratio
RPM
9
-
8/10/2019 catalogo- ge752 . curvas.pdf
12/61
PRODUCT INFORMATIONDC TOP DRIVE MODEL 6027E
MODEL 6027E-939 STANDARD GEAR RATIO TORQUE CURVE
SHUNT
Curves based onGE Model 761, DC Drilling Motor (600 HP) Shunt 9.387:1 Gear Ratio
0
5000
10000
15000
20000
0 50 100 150 200 250 300
TO
RQ
UE
Continuous
RPM
10
-
8/10/2019 catalogo- ge752 . curvas.pdf
13/61
PRODUCT INFORMATIONDC TOP DRIVE MODEL 6027E
MODEL 6027E-773 TORQUE CURVE
SERIES
0
5000
10000
15000
20000
25000
0 50 100 150 200 250 300
RPM
TORQUE
Continuous
Curves based on GE Model 761, DC Drilling Motor (600 HP) Series 7.726:1 Gear Ratio
11
-
8/10/2019 catalogo- ge752 . curvas.pdf
14/61
PRODUCT INFORMATIONDC TOP DRIVE MODEL 6027E
MODEL 6027E-773 TORQUE CURVE
SHUNT
0
5000
10000
15000
20000
0 50 100 150 200 250 300
RPM
TO
RQ
UE
Continuous
Curves based on GE Model 761, DC Drilling Motor (600 HP) Shunt 7.726:1 Gear Ratio
12
-
8/10/2019 catalogo- ge752 . curvas.pdf
15/61
PRODUCT
INFORMATIONDC TOP DRIVE MODEL 8035E
MODEL 8035E TOP DRIVE
GENERAL ARRANGEMENT.
TRAVELING BLOCK)(DEPENDENT ON
BLOCK INTERFACE
DOWN POSITIONQUILL SHOULDER
LINK SUPPORT
240.8
5(20'-0.8
5")REF
8.0
0FLOAT
90.8
8
ELEVATOR (BY CUSTOMER)
13
-
8/10/2019 catalogo- ge752 . curvas.pdf
16/61
PRODUCT
INFORMATIONDC TOP DRIVE MODEL 8035E
SpecificationsTop Drive Model 8035E-500
Static Hoist Rating
Elevator Load Path 350 Tons 318 Tonnes
Quill Load Path 350 Tons 318 Tonnes
Electric Motor GE 752 High Torque Shunt
Output Power
Continuous 1 130 HP 840 KW
Intermittent 1 297 HP 967 KW
Gear Ratio 5.000:1
Continuous Torque Rating 30 000 ft-lb (40 700 Nm) @ 180 RPM
Intermittent Torque Rating 33 300 ft-lb (45 100 Nm) @ 180 RPM
Maximum Speed Rating 20 300 ft-lb (27 500 Nm) @ 265 RPM
Brake Capacity 30 000 ft-lb 40 700 Nm
Maximum Electric Motor Torque 33 300 ft-lb 45 100 Nm
(Make-Up Limit is operator adjustable.)
Torque Boost Torque
Make-Up 24 000 ft-lb 32 500 Nm
Break Out 37 500 ft-lb 50 800 Nm
Maximum Connection B /O Torque 70 800 ft-lb 96 000 Nm
(Make-Up Li mit is operator adjus table.)
Pipe Handler Orientation Unlimited, remote controlled
Pipe Handler Lock 32 positions, remote controlled
Back-up Wrench Gripper 5.75 to 9.0 inches.
Diameter Range 3.75 to 7.0 inches with alternate die blocks
Back-Up Wrench Maximum Travel 43.25 inches 110 cm
Quill Connection 6-5/8 Reg.
Water Course Diameter 3.0 inches 7.6 cm
Circulating Pressure Rating - Standard 5 000 PSI 34 500 KPa
Circulating Pressure Rating - Optional 7 500 PSI 51 700 KPa
Floating Quill Travel 8.0 inches 20 cm
Link Counterbalance Travel 8.0 inches 20 cm
14
-
8/10/2019 catalogo- ge752 . curvas.pdf
17/61
PRODUCT
INFORMATIONDC TOP DRIVE MODEL 8035E
Cooling System STANDARD: Local Blower
15 HP, 2 800 scfm flow(11 KW, 80 m3/min)flow
Lubrication System 2 HP, 4 GPM flow1.5 KW, 15 l/minflow
Hydraulic Requirement 12 GPM flow 45 l/min flow
2 350 PSI 16 200 KPa
Pressure compensated control
(see HPU Specifications)
Electrical Power GE 752 High Torque Shunt Motor
Max. continuous armature current 1 250 Amps
Max. intermittent armature current 1 435 Amps
Max. armature voltage 750 VDC
Field Supply 60, 40, 30 Amps
Weight (without blocks) 27 000 lb 12 200 Kg
15
-
8/10/2019 catalogo- ge752 . curvas.pdf
18/61
PRODUCT
INFORMATIONDC TOP DRIVE MODEL 8035E
MODEL 8035E-500 TORQUE CURVE
0
5000
10000
15000
20000
25000
30000
35000
0 50 100 150 200 250 300
RPM
Torque
Continuous
Curves based on GE Model 752, DC Drilling Motor (1130 HP) 5.00:1 Gear Ratio
16
-
8/10/2019 catalogo- ge752 . curvas.pdf
19/61
PRODUCT
INFORMATIONDC TOP DRIVE MODEL 1050E
MODEL 1050E-500TOP DRIVE
GENERALARRANGEMENT
GRIPPER CYLINDER
EXTENDED
GRIPPER CYLINDERRETRACTED
BACKUPWRENCH
TRAVEL
17
-
8/10/2019 catalogo- ge752 . curvas.pdf
20/61
PRODUCT
INFORMATIONDC TOP DRIVE MODEL 1050E
MODEL 1050E-712 TOP DRIVE
GENERAL ARRANGEMENT
35.25
TO
RQUEGUIDE
FA
CEOF
29.0012.00
8.00
MAX
MIN
24.00
50.00
47.88
38.50
V-DOOR VIEW
DOWN POSITION
TOP OF DRILL PIPE
QUILL SHOULDER
100.82
253.92
8.00FLOAT
All dimensions in inches.
18
-
8/10/2019 catalogo- ge752 . curvas.pdf
21/61
PRODUCT
INFORMATIONDC TOP DRIVE MODEL 1050E
Specifications
Top Drive Model 1050EStatic Hoist Rating
Elevator Load Path 500 Tons 454 Tonnes
Quill Load Path 500 Tons 454 Tonnes
Electric Motor GE 752 High Torque Shunt
Output Power
Continuous 1 130 HP 840 KWIntermittent 1 297 HP 967 KW
Gear Ratio 5.000:1 7.120:1
Continuous Torque Rating 30 000 ft-lb(40 700 Nm)@ 180 RPM
42 700 ft-lb(57 900 Nm)@ 125 RPM
Intermittent Torque Rating 33 300 ft-lb(45 100 Nm)@ 180 RPM
47 400 ft-lb(64 300 Nm)@ 125 RPM
Maximum Speed Rating 20 300 ft-lb(27 500 Nm)@ 265 RPM
28 900 ft-lb(39 200 Nm)@ 185 RPM
Brake Capacity 30 000 ft-lb(40 700 Nm)
42 700 ft-lb(57 900 Nm)
Maximum Electric Motor Torque 47 400 ft-lb(64 300 Nm)
(Make-Up Limit i s operator adjustable)
33 300 ft-lb(45 100 Nm)
Torque Boost TorqueMake-Up
24 000 ft-lb(32 500 Nm)
24 000 ft-lb(32 500 Nm)
Break Out 37 500 ft-lb(50 800 Nm)
37 500 ft-lb(50 800 Nm)
Maximum Connection B /O Torque 70 800 ft-lb(96 000 Nm)
84 900 ft-lb(115 100 Nm)
(Make-Up Limi t is operator adjus table.)
Pipe Handler Orientation Unlimited, remote controlled
Pipe Handler Lock 32 positions, remote controlled
Back-up Wrench Gripper 5.75 to 9.0 inches.
Diameter Range 3.75 to 7.0 inches with alternate die blocks
Back-Up Wrench Maximum Travel 43.25 inches 110 cm
Quill Connection 6-5/8 Reg.
Water Course Diameter 3.0 inches 7.6 cm
Circulating Pressure Rating - Standard 5 000 PSI 34 500 KPa
19
-
8/10/2019 catalogo- ge752 . curvas.pdf
22/61
PRODUCT
INFORMATIONDC TOP DRIVE MODEL 1050E
Circulating Pressure Rating - Optional 7 500 PSI 51 700 KPa
Floating Quill Travel 8.0 inches 20 cm
Link Counterbalance Travel 8.0 inches 20 cm
Cooling System STANDARD: Local Blower
15 HP, 2 800 scfm flow (11 KW, 80m3/min)flow
Lubrication System 2 HP, 4 GPM flow 1.5 KW, 15 l/min flow
Hydraulic Requirement 12 GPM flow 45 I/min flow
2 350 PSI 16 200 Kpa
Pressure compensated control
(see HPU Specifications)
Electrical Power GE 752 High Torque Shunt Motor
Max. continuous armature current 1 250 Amps
Max. intermittent armature current 1 435 Amps
Max. armature voltage 750 VDC
Field Supply 60, 40, 30 Amps
Weight (without b locks) 28 000 lb 12 700 Kg
20
-
8/10/2019 catalogo- ge752 . curvas.pdf
23/61
PRODUCT
INFORMATIONDC TOP DRIVE MODEL 1050E
MODEL 1050E-500TORQUE CURVE
Curves based on GE Model 752, DC Drilling Motor (1130 HP) 5.00:1 Gear Ratio
0
5000
10000
15000
20000
25000
30000
35000
0 50 100 150 200 250 300
RPM
Torque
Continuous.
21
-
8/10/2019 catalogo- ge752 . curvas.pdf
24/61
PRODUCT
INFORMATIONDC TOP DRIVE MODEL 1050E
MODEL 1050E-712 TORQUE CURVE
0
500010000
15000
20000
25000
30000
35000
40000
45000
50000
0 50 100 150 200 250
RPM
Torque
Continuous.
Curves based on GE Model 752, DC Drilling Motor (1130 HP) 7.120:1 Gear Ratio
22
-
8/10/2019 catalogo- ge752 . curvas.pdf
25/61
PRODUCT
INFORMATIONDC TOP DRIVE MODEL 1175E
MODEL 1175E TOP DRIVE
GENERAL ARRANGEMENT.
23
-
8/10/2019 catalogo- ge752 . curvas.pdf
26/61
PRODUCT
INFORMATIONDC TOP DRIVE MODEL 1175E
SpecificationsTop Drive Model 1175E
Static Hoist Rating
Elevator Load Path 750 Tons 680 Tonnes
Quill Load Path*Optional 3 Water Course
600 Tons750 Tons
544 Tonnes680 Tonnes
Electric Motor GE 752 High Torque Shunt
Output Power
Continuous 1 130 HP 840 KWIntermittent 1 297 HP 967 KW
Gear Ratio 7.120:1
Continuous Torque Rating 42 700 ft-lb (57 900 Nm) @125 RPM
Intermittent Torque Rating 47 400 ft-lb (64 300 Nm) @125 RPM
Maximum Speed Rating 28 900 ft-lb (39 200 Nm) @185 RPM
Brake Capacity 42 700 ft-lb (57 900 Nm)
Maximum Electric Motor Torque 47 400 ft-lb (64 300 Nm)
(Make-Up Limit i s operator adjustable)
Torque Boost TorqueMake-Up 24 000 ft-lb (32 500 Nm)
Break Out 37 500 ft-lb (50 800 Nm)
Maximum Connection B/O Torque 84 900 ft-lb (115 100 Nm)
(Make-Up Limi t is operator adjus table.)
Pipe Handler Orientation Unlimited, remote controlled
Pipe Handler Lock 418 positions, remote controlled
Back-up Wrench Gripper 5.75 to 9.0 inches.
Diameter Range 3.75 to 7.0 inches with alternate die blocks
Back-Up Wrench Maximum Travel 43.25 inches 110 cm
Quill Connection NC61
Water Course Diameter 4.0 inches (Optional 3.0) 10.13 cm
Circulating Pressure Rating - Standard 7 500 PSI 51 700 KPa
Circulating Pressure Rating - Optional 7 500 PSI 51 700 KPa
Floating Quill Travel 8.0 inches 20 cm
Link Counterbalance Travel 8.0 inches 20 cm
24
-
8/10/2019 catalogo- ge752 . curvas.pdf
27/61
PRODUCT
INFORMATIONDC TOP DRIVE MODEL 1175E
Cooling System STANDARD: Local Blower
15 HP, 2 800 scfm flow (11 KW, 80m3/min) flow
Lubrication System 2 HP, 4 GPM flow 1.5 KW, 15 l/min flow
Hydraulic Requirement 12 GPM flow 45 I/min flow
2 350 PSI 16 200 Kpa
Pressure compensated control
(see HPU Specifications)
Electrical Power GE 752 High Torque Shunt Motor
Max. continuous armature current 1 250 Amps
Max. intermittent armature current 1 435 Amps
Max. armature voltage 750 VDC
Field Supply 60, 40, 30 Amps
Weight (without b locks) 31 000 lb 14 100 Kg
25
-
8/10/2019 catalogo- ge752 . curvas.pdf
28/61
PRODUCT
INFORMATIONDC TOP DRIVE MODEL 1175E
MODEL 1175E TORQUE CURVE
0
10000
20000
30000
40000
50000
0 50 100 150 200
RPM
Torque
Continuous
Curves based on GE Model 752, DC Drilling Motor (1130 HP) 7.12:1 Gear Ratio
26
-
8/10/2019 catalogo- ge752 . curvas.pdf
29/61
PRODUCT
INFORMATIONAC TECHNOLOGY
AC Technology
Since the advantages of using top drives are well documented, the decision for mostoperators is whether to use DC or AC technology. Both have advantages that warrantconsideration depending on application.
The primary benefit of AC top drives is a significant better power factor. AC motorsalso have a better speed range and can be run at 200% of base speed and above. Thehorsepower characteristics of an AC motor are far superior to the DC equivalent. DC
motors can maintain maximum horsepower at only one speed while AC motorsmaintain fill horsepower from base speed to approximately 150% ofbase speed.
Other advantages to our AC Top Drive Drilling Systems are:
Can stall motor for an indefinite period, with zero to maximum torque applied.
Enclosed, EExeor TEFC motor possible. This would eliminate the blower hose(arather cumbersome, but necessary feature on the DC motor).
Less maintenance due to lack of brushes. With a TEFC motor, this becomesdouble important, considering that no dirt or moisture will be entering the motorand its windings.
By utilizing a 6pulse front-end variable frequency drive, substantial reduction inharmonics to the point where it will meet and exceed requirements of IEEE 581standards, can be achieved. This feature becomes valuable if drilling power isobtained from Hiline Utility distribution.
Our innovative modular design of the drive also allows for plug and play repairand maintenance.
New technology. Utilization of latest components and engineering know-how.
27
-
8/10/2019 catalogo- ge752 . curvas.pdf
30/61
PRODUCT
INFORMATIONAC TOP DRIVE MODEL 4017AC
MODEL 4017AC TOP DRIVE
GENERAL ARRANGEMENT.
V- DOOR VIEW
TOP VIEW
DRILLER SIDE VIEW
43.4
9
18-3.2
1
24.16 30.91
21.5
0
27.8
7
28
-
8/10/2019 catalogo- ge752 . curvas.pdf
31/61
PRODUCT
INFORMATIONAC TOP DRIVE MODEL 4017AC
SpecificationsTop Drive Model 4017AC
Static Hoist Rating
Elevator Load Path 175 Tons
Quill Load Path 175 Tons
API Bear ing Rating
Electric Motor 400 HP AC
Output Power
Continuous 400 HP 300 KW
Intermittent 600 HP 450 KW
Gear Ratio 12.262:1
Continuous Torque Rating 22 800 ft-lb 30 900 Nm
Intermittent Torque Rating 30 000 ft-lb 40 675 Nm
Maximum Speed Rating 225 RPM
Brake Capacity 12 000 ft-lb 16 300 Nm
Maximum Electric Motor Torque 28 400 ft-lb 38 500 Nm
(Make-Up Limit is operator adjustable.)
Maximum Connection B/O Torque 28 400 ft-lb 38 500 Nm(Make-Up Limit is operator adjustable.)
Pipe Handler Orientation Unlimited, remote controlled.
Pipe Handler Lock31 positions, remote controlled.
Back-up Wrench Gripper 0 up to 7.0 inches. 0 up to 18 cm.
Diameter Range
Back-Up Wrench Maximum Travel 26.75 inches 68 cm
Quill Connection NC 46
Water Course Diameter 2-9/16 inches. 6.5 cm
Circulating Pressure Rating - Standard 5 000 PSI 34 500 Kpa
Circulating Pressure Rating - Optional 7 500 PSI 51 700 Kpa
Floating Quill Travel 7.0 inches. 18 cm
29
-
8/10/2019 catalogo- ge752 . curvas.pdf
32/61
PRODUCT
INFORMATIONAC TOP DRIVE MODEL 4017AC
Link Counterbalance Travel 7.0 inches. 18 cm
Cooling System STANDARD: Local Blower
5 HP, 1 380 scfm flow (6 KW, 50 m3/min) flow
Lubrication System 2 HP, 4 GPM flow 1.5 KW, 15 l/min flow
Hydraulic Requirement 12 GPM flow 45 l/min flow
2 350 PSI 16 200 KPa
Pressure compensated control
(see HPU Specifications)
Weight (without b locks) 15 000 lb 6 800 Kg
30
-
8/10/2019 catalogo- ge752 . curvas.pdf
33/61
PRODUCT
INFORMATIONAC TOP DRIVE MODEL 4017AC
MODEL 4017AC TORQUE CURVE
0
5000
10000
15000
20000
25000
30000
0 50 100 150 200
RPM
TORQ
UE(
ft/lbs)
Continuous Torque
Curves based on 400 HP AC Motor, 12.262:1 Gear Ratio
31
-
8/10/2019 catalogo- ge752 . curvas.pdf
34/61
PRODUCT
INFORMATIONAC TOP DRIVE MODEL 6027AC
MODEL 6027ACTOP DRIVE
GENERAL ARRANGEMENT.
32
-
8/10/2019 catalogo- ge752 . curvas.pdf
35/61
PRODUCT
INFORMATIONAC TOP DRIVE MODEL 6027AC
SpecificationsTop Drive Model 6027AC
Static Hoist Rating
Elevator Load Path 275 Tons 249 Tonnes
Quill Load Path 275 Tons 249 Tonnes
Electric Motor WEG 600 HP AC
Gear Ratio 9.387:1
Continuous Torque Rating 30 000 ft-lb
(40 700 Nm)@ 105 RPM
Intermittent Torque Rating 30 000 ft-lb(40 700 Nm)@ 105 RPM
Maximum Speed Rating 15 400 ft-lb(20 880 Nm)@ 205 RPM
Brake Capacity 20 000ft-lb(27 400 Nm)
Maximum Connection B/O Torque 67 500 ft-lb
(90 800 Nm)
(Make-Up Limit is operatoradjustable)
Torque Boost Torque
Make-Up 24 000 ft-lb(32 500 Nm)
Break Out 37 500 ft-lb(50 800 Nm)
Pipe Handler Orientation Unlimited, remote controlled
Pipe Handler Lock 33 positions, remote controlled
Back-up Wrench Gripper 5.75 to 9.0 inches.
Diameter Range 3.75 to 7.0 inches with alternate die blocks
Back-Up Wrench Maximum Travel 26.75 inches 68 cm
Quill Connection NC50
33
-
8/10/2019 catalogo- ge752 . curvas.pdf
36/61
PRODUCT
INFORMATIONAC TOP DRIVE MODEL 6027AC
Water Course Diameter 2.6 inches 6.6 cm
Circulating Pressure Rating - Standard 5 000 PSI
Circulating Pressure Rating - Optional 7 500 PSI
Floating Quill Travel 7.9 inches 20 cm
Link Counterbalance Travel 7.0 inches 18 cm
Cooling System STANDARD:Local Blower
7.5 HP, 1 680scfm flow
(6 KW, 50m3/min) flow
Lubrication System 2 HP, 4 GPMflow
1.5 KW, 15l/min flow
Hydraulic Requirement 12 GPM flow 45 l/min flow
2 350 PSI 16 200 KPa
Pressure compensated control (see HPU Specifications)
Weight (without b locks) 18 000 lb(8 200 Kg)
34
-
8/10/2019 catalogo- ge752 . curvas.pdf
37/61
PRODUCT
INFORMATIONAC TOP DRIVE MODEL 6027AC
MODEL 6027AC TORQUE CURVE
0
5000
10000
15000
20000
25000
30000
35000
40000
0 50 100 150 200 250 300RPM
Torque
Continuous
Curve based on WEG AC Motor 600 HP, 9.387:1 Gear Ratio
35
-
8/10/2019 catalogo- ge752 . curvas.pdf
38/61
PRODUCT
INFORMATIONAC TOP DRIVE MODEL 8050AC
MODEL 8050ACTOP DRIVE
GENERAL ARRANGEMENT.
All dimensions in inches.
35.25
TORQUE BOOST
HANDLER LOCK
TORQUEGUIDE
FACEOF
29.0012.00
8.00
MAX
MIN
24.00
50.00
47.88
38.50
V-DOOR VIEW
DOWN POSITION
TOP OF DRILL PIPE
QUILL SHOULDER
100.82
253.92
8.00FLOAT
36
-
8/10/2019 catalogo- ge752 . curvas.pdf
39/61
PRODUCT
INFORMATIONAC TOP DRIVE MODEL 8050AC
SpecificationsTop Drive Model 8050AC
Static Hoist Rating
Elevator Load Path 500 Tons 454 Tonnes
Quill Load Path 500 Tons 454 Tonnes
Electric Motor GE B20 AC, 600 VAC0-100 HZ
Output Power
Continuous 800 HP
Intermittent 1 100 HP
Gear Ratio 7.120:1
Continuous Torque Rating 39,200 ft-lb(53,148 Nm)@109 RPM
Intermittent Torque Rating 52,000 ft-lb(70,503 Nm)@120 RPM
Maximum Speed Rating 20 000 ft-lb(27,116 Nm)@228 RPM
Brake Capacity 50 000 ft-lb(70 800 Nm)
Torque Boost Torque
Make-Up
24 000 ft-lb(32 500 Nm)
Break Out 37 500 ft-lb(50 800 Nm)
Maximum Connection B/O Torque(Make-Up Limi t is operator adjus table.)
90 000 ft-lb(122 000 Nm)
Pipe Handler Orientation Unlimited, remote controlled
Pipe Handler Lock 418 positions, remote controlled
Back-up Wrench Gripper 5.75 to 9.0 inches.Diameter Range 3.75 to 7.0 inches with alternate die blocks
Back-Up Wrench Maximum Travel 43.25 inches 110 cm
Quill Connection 6-5/8 Reg.
Water Course Diameter 3.0 inches 7.6 cm
Circulating Pressure Rating - Standard 5 000 PSI 34 500 KPa
Circulating Pressure Rating - Optional 7 500 PSI 51 700 KPa
37
-
8/10/2019 catalogo- ge752 . curvas.pdf
40/61
PRODUCT
INFORMATIONAC TOP DRIVE MODEL 8050AC
Floating Quill Travel 8.0 inches 20 cm
Link Counterbalance Travel 8.0 inches 20 cmCooling System STANDARD: Local Blower
15 HP, 2 800 scfm flow (11 KW, 80m3/min) flow
Lubrication System 2 HP, 4 GPM flow 1.5 KW, 15l/min flow
Hydraulic Requirement 12 GPM flow 45 l/min flow
2 350 PSI 16 200 KPa
Pressure compensated control
(see HPU Specifications)
Electrical Power GE B20 AC Motor
Max. continuous current 1 060 Amps
Max. intermittent current 1 470 Amps
Frequency 0 - 90 Hz
Weight (without blocks) 29 000 lb 13 200 Kg
38
-
8/10/2019 catalogo- ge752 . curvas.pdf
41/61
PRODUCT
INFORMATIONAC TOP DRIVE MODEL 8050AC
MODEL 8050ACTORQUE CURVE
0
10000
20000
30000
40000
50000
60000
70000
80000
0 50 100 150 200 250RPM
Torque
Continuous
Curve based on GE B-20 AC Motor (1150 HP), 7.120:1 Gear Ratio
39
-
8/10/2019 catalogo- ge752 . curvas.pdf
42/61
PRODUCT
INFORMATIONAC TOP DRIVE MODEL 1250AC
MODEL 1250AC TOP DRIVE
GENERAL ARRANGEMENT.
All dimensions in inches.
35.25
TORQUE BOOST
HANDLER LOCK
TO
RQUE
GUIDE
FACE
OF
29.0012.00
8.00
MAX
MIN
24.00
50.00
47.88
38.50
V-DOOR VIEW
DOWN POSITION
TOP OF DRILL PIPE
QUILL SHOULDER
100.82
253.92
8.00FLOAT
40
-
8/10/2019 catalogo- ge752 . curvas.pdf
43/61
PRODUCT
INFORMATIONAC TOP DRIVE MODEL 1250AC
SpecificationsTop Drive Model 1250AC
Static Hoist Rating
Elevator Load Path 500 Tons 454 Tonnes
Quill Load Path 500 Tons 454 Tonnes
Electric Motor GE B20 AC
Output Power
Continuous 1 150 HP 860 KW
Intermittent 1 400 HP 1 040 KWGear Ratio 6.808:1
StandardContinuous Torque Rating 51 400 ft-lb
(69 700 Nm)@118 RPM
Intermittent Torque Rating 71 500 ft-lb(96 900 Nm)@103 RPM
Maximum Speed Rating 23 700 ft-lb(32 100 Nm)@ 256 RPM
Brake Capacity 52 300 ft-lb(70 900 Nm)
Maximum Electric Motor Torque(Make-Up Limit is operator adjustable.)
71 500 ft-lb(96 900 Nm)
Torque Boost Torque
Make-Up 24 000 ft-lb(32 500 Nm)
Break Out 37 500 ft-lb(50 800 Nm)
Maximum Connection B/O Torque(Make-Up Limit is operator adjustable.)
90 000 ft-lb(122 000 Nm)
Pipe Handler Orientation Unlimited, remote controlledPipe Handler Lock 418 positions, remote controlled
Back-up Wrench Gripper 5.75 to 9.0 inches.
Diameter Range 3.75 to 7.0 inches with alternate die blocks
Back-Up Wrench Maximum Travel 43.25 inches 110 cm
Quill Connection 6-5/8 Reg.
Water Course Diameter 3.0 inches 7.6 cm
41
-
8/10/2019 catalogo- ge752 . curvas.pdf
44/61
PRODUCT
INFORMATIONAC TOP DRIVE MODEL 1250AC
Circulating Pressure Rating -Standard
5 000 PSI 34 500 KPa
Circulating Pressure Rating - Optional 7 500 PSI 51 700 KPa
Floating Quill Travel 8.0 inches 20 cm
Link Counterbalance Travel 8.0 inches 20 cm
Cooling System STANDARD: Local Blower
15 HP, 2 800 scfm flow (11 KW, 80 m3/min)flow
Lubrication System 2 HP, 4 GPM flow 1.5 KW, 15 l/minflow
Hydraulic Requirement 12 GPM flow 45 l/min flow
2 350 PSI 16 200 KPa
Pressure compensated control
(see HPU Specifications)
Electrical Power GE B20 AC Motor
Max. continuous current 1 060 Amps
Max. intermittent current 1 470 Amps
Max. voltage 600 VAC
Frequency 0 - 90 Hz
Weight (without b locks) 29 000 lb 13 200 Kg
42
-
8/10/2019 catalogo- ge752 . curvas.pdf
45/61
PRODUCT
INFORMATIONAC TOP DRIVE MODEL 1250AC
MODEL 1250AC TORQUE CURVE
0
10000
20000
30000
40000
50000
60000
70000
80000
0 50 100 150 200 250 300
RPM
Torque
Continuous
Curve based on GE B-20 AC Motor (1150 HP), 6.808:1 Gea Ratio
43
-
8/10/2019 catalogo- ge752 . curvas.pdf
46/61
PRODUCTINFORMATION
AC TOP DRIVE MODEL 1275AC
MODEL 1275AC TOP DRIVE
GENERAL ARRANGEMENT.
All dimensions in inches.
88.61
51.15
8.00
283.93
MOTOR
RETRACTED
GRIPPER CYLINDEREXTENDED
GRIPPER CYLINDER
DRILLER SIDE VIEW
ELEVATOR LINK(BY CUSTOMER)
8 FT SHOWN
MANUAL LOWER WELCONTROL VALVE
LINK TILT,
BI-DIRECTIONAL
ROTARY MANIFOLD
LINK SUPPORT
GEAR CASE
43.25
BACKUPWRENCH
TRAVEL
QUILLFLOAT
12.00
8.00
46.62
28.55
ROTARY HOSE CONNECTION
TRAVELING BLOCK(BY CUSTOMER)
24.00
40.66
V-DOOR VIEW
ELEVATOR
(BY CUSTOMER)
44
-
8/10/2019 catalogo- ge752 . curvas.pdf
47/61
PRODUCTINFORMATION
AC TOP DRIVE MODEL 1275AC
SpecificationsTop Drive Model 1275AC
Static Hoist RatingElevator Load Path 750 Tons 680 Tonnes
Quill Load Path* Optional3Water Course
600 Tons750 Tons
544 Tonnes680 Tonnes
Electric Motor GE B20 AC
Output Power
Continuous 1 150 HP 860 KW
Intermittent 1 400 HP 1 040 KW
Gear Ratio 6.808:1
Continuous Torque Rating 51 400 ft-lb(69 700 Nm)@ 118 RPM
Intermittent Torque Rating 71 500 ft-lb(9 690 Nm)@ 103 RPM
Maximum Speed Rating 23 700 ft-lb(32 100 Nm)@ 256 RPM
Brake Capacity 52 300 ft-lb(70 900 Nm)
Maximum Electric Motor Torque 71 500 ft-lb(Make-Up Limi t is operator adjustable.) (96 900 Nm)
Torque Boost Torque
Make-Up 24 000 ft-lb(32 500 Nm)
Break Out 37 500 ft-lb(50 800 Nm)
Maximum Connection B/O Torque(Make-Up Limi t is operator adjustable.)
90 000 ft-lb(122 000 Nm)
Pipe Handler Orientation Unlimited, remote controlled
Pipe Handler Lock 418 positions, remote controlledBack-up Wrench Gripper 5.75 to 9.0 inches.
Diameter Range 3.75 to 7.0 inches with alternate die blocks
Back-Up Wrench Maximum Travel 43.25 inches 110 cm
Quill Connection 7-5/8 Reg.
Water Course Diameter* Optional
4.0 inches3.0 inches
10.2 cm76.5 cm
Circulating Pressure Rating -Standard
7 500 PSI 51 700 KPa
45
-
8/10/2019 catalogo- ge752 . curvas.pdf
48/61
PRODUCTINFORMATION
AC TOP DRIVE MODEL 1275AC
Circulating Pressure Rating -Optional
11 200 PSI 77 600 KPa
Floating Quill Travel 8.0 inches 20 cm
Link Counterbalance Travel 8.0 inches 20 cm
Cooling System STANDARD: Local Blower
15 HP, 2 800 scfm flow (11 KW, 80 m3/min)flow
Lubrication System 2 HP, 4 GPM flow 1.5 KW, 15 l/min flow
Hydraulic Requirement 12 GPM flow 45 l/min flow
2 350 PSI 16 200 KPa
Pressure compensated control
(see HPU Specifications)
Electrical Power GE B20 AC Motor
Max. continuous current 1 060 Amps
Max. intermittent current 1 470 Amps
Max. voltage 600 VAC
Frequency 0-90 Hz
Weight (without b locks) 30 000 lb 13 600 Kg
46
-
8/10/2019 catalogo- ge752 . curvas.pdf
49/61
PRODUCTINFORMATION
AC TOP DRIVE MODEL 1275AC
MODEL 1275AC TORQUE CURVE
0
10000
20000
30000
40000
50000
60000
70000
80000
0 50 100 150 200 250 300
RPM
Torque
Continuous
Curve based on GE B-20 AC Motor (1150 HP), 6.808:1 Gear Ratio
47
-
8/10/2019 catalogo- ge752 . curvas.pdf
50/61
PRODUCTINFORMATION
TORQUE GUIDES
Torque Guides
Canrig Drilling Technology offers a Portableand FixedTorque Guide system.The following information describes each system.
The Portable Torque Guide
Canrig Portable Torque Guide Systems provides lateral guidance and torquereaction for the top drive unit without imparting torsional stresses into themast/derrick. The PortableTorque Guide is designed for ease of installation and
portability between rigs. It is installed vertically, after erection of the mast.1. Five section folding Torque Guide2. Hinged connection hardware between the Torque Guide sections.3. Cable tensioning system including hydraulic cylinders, valves, plumbing cable
and hardware for locking the Torque Guide connections in the workingposition.
4. Hoist rigging for vertical rig-up/down of the system.5. All Torque Guide sections plus the Top Drive Unit plus the Services fold up
onto a common built-in skid for transport.6. No mast erection analysis required.7. Provision for mounting the Services Support Frame (SSF) on Section 3 of the
Torque Guide.
Portable Torque Guide Transport Position
48
-
8/10/2019 catalogo- ge752 . curvas.pdf
51/61
PRODUCTINFORMATION
TORQUE GUIDES
Canrig s Portable Torque GuideErection Sequence
Skid Position atthe V Door
Position TorqueGuide Vertically
Installation Complete
Commence LiftUsing theRig Blocks
49
-
8/10/2019 catalogo- ge752 . curvas.pdf
52/61
PRODUCTINFORMATION
TORQUE GUIDES
Top Drive Services Self Contained (Portable)
Provisions for electric and hydraulic services are built into the Folding TorqueGuide. The system requires little or no interface to the rig and minimal connectionsfor rig-up.
1. Adjustable Services Support Frame (SSF), mounted to Section 3 of the TorqueGuide and positioned at approximately 75 ft. elevation above the floor, forsupport of the service loops and Upper Torque Guide Junction Box.
2. Lower Torque Guide Junction Box for connection of the supply cables to theTorque Guide electrical cables.
3. Torque Guide electrical cables from the Lower Torque Guide Junction Box tothe Upper Torque Guide Junction Box. These cables are fixed to the TorqueGuide sections and fold with the Torque Guide for transport.
4. Upper Torque Guide Junction Box for connection of the Torque Guideelectrical cables to the electrical service loop.
5. Hydraulic supply and return lines from the base of the Torque Guide to theSSF. These lines are fixed to the Torque Guide sections and fold with theTorque Guide for transport.
6. Electric Service Loop including power and control cables from the SSF to the
Top Drive Unit (TDU). The Electric Service Loop is transported on thecollapsed Torque Guide skid.
7. Hydraulic Service Loop, including pressure and return lines, from the SSF tothe TDU. The Hydraulic Service Loop is transported on the collapsed TorqueGuide skid.
50
-
8/10/2019 catalogo- ge752 . curvas.pdf
53/61
PRODUCTINFORMATION
TORQUE GUIDES
The Fixed Torque Guide
Canrig Torque Guide Systems provides lateral guidance and torque reaction for thetop drive unit without imparting torsional stresses into the mast/derrick. The FlangedType Torque Guide is divided into sections corresponding to the mast sections.Each guide section is laterally fixed to its mast section with torque-isolatingconnections. The Torque Guide sections are joined with bolted flanges. Subject tomast erection stress constraints, the Flanged Torque Guide can be installedhorizontally and erected with the mast.1. Four (+/-) section Torque Guide, custom built for the mast/derrick.2. Flange connections between the sections.3. Mast connection brackets (2 per section):
Torque isolating.
Free axial movement of the torque guide relative to the mast/derrick.
Adjustable lateral positioning.
Welded attachment to the mast girts (Standard); clamped-style optional.4. Transport Skid for the Top Drive Unit built into the bottom section of the Torque
Guide.5. Application engineering and installation drawings.
6. Mast erection stress analysis and any associated mast upgrades are excluded.7. Installation, alignment and labor costs are excluded.
Top Drive Services Mast/Derrick Mounted(Fixed)
Provisions for electric and hydraulic services are installed onto the mast/derrick.1. Mast/Derrick Junction Box, shipped loose. Provisions for hard-wired
connections are included for both the feeder and Electric Service Loop sides.2. Electric Service Loop, including power and control cables, from the
Mast/Derrick Junction Box to the Top Drive Unit(TDU). ESL/TDU connectionsare hard wired.
3. Hydraulic Service Loop, including pressure and return lines, from themast/derrick termination to the TDU.
4. OPTION -Feeder Electric Service Loop and Floor Junction Box:
Floor Junction Box for connection of the supply cables to themast/derrick feeder cables.
Electric Service Loop for stationary application between the FloorJunction Box and the Mast/Derrick Junction Box.
51
-
8/10/2019 catalogo- ge752 . curvas.pdf
54/61
PRODUCT
INFORMATIONELECTRICAL AND HYDRAULIC
Electrical and Hydraulic Configurations
The Canrig Top Drive Support Unit is a self-contained power and controlpackage that is an integral element of the Canrig Portable Top Drive System.
The Top Drive Support Unit (TDSU)Requires only 600V power from rig or standalone genset
1. Standard Compact TDSU Micro Building:
Four-point crane-lift style.
Dimensions as per Specifications.
2. DC models c/w a SCR.3. AC models c/w a Flux-Vector Variable Frequency Drive.
Six pulse VFD rectifier with a 810 VDC link for near-unitypower factor load.
Modular drive configuration with three identical inverter modules.
User friendly message display panel, with built-in self-diagnostics.
Internal air cooling system.4. Top Drive Control & Interface Panel (CIP):
CIP cabinet for Safe Area installation; standard dimensions.
On Shunt DC models a Dual (redundant) field supplies for the top drive,c/w static reversing and field weakening (3levels).
HPU motor controls.
Supply breaker for the On-Board MCC.
Control Power Transformer and Regulator.
Top drive control PLC: Chassis.
Processor c/w EEPROM memory module.Proprietary Canrig TD System Control Logic.Input and output devices for local functions.Communications adapter for the TD Control Console, TDU Flex
I/O and Advanced Diagnostic System. Power supplies (dual, redundant) for the Flex I/O on the Top Drive Unit.
Communications interface to the Flex I/O on the Top Drive Unit.
Interface connections to the SCR / VFD, TD Control Console and the TopDrive Unit.
Control cables between the CIP and the TD Control Console.5. Dual (redundant) air conditioners for the SCR / VFD/Control room.
52
-
8/10/2019 catalogo- ge752 . curvas.pdf
55/61
PRODUCT
INFORMATIONELECTRICAL AND HYDRAULIC
6. Twin Hydraulic Power Unit for auxiliary functions:
Twin, fully redundant, electrically driven hydraulic pump assemblies.
Suction, pressure and return filtration.
Air to oil cooling system.
Stainless steel reservoir.
Kidney loop cooling and filtration circulation system.
Temperature and oil level alarm sensors.
Unitized skid package c/w drip tray.7. Electrical Cables/Hydraulic Hoses:
Power Cables - TDSU to Lower Torque Guide Junction Box.
Control Cables:
TDSU to Lower Torque Guide Junction BoxTDSU to the Rig SCR / VFD (for optional power limit and mudpump status signals).
Hydraulic Lines from the TDSU to the Torque Guide base, c/wconnectors.
8. Pre-commissioned.9. Optionally available is a Land-Configuration TDSU Packaging Upgrade:
40 ft Oilfield-style skid.
Mounting provisions for the Sub-Compact TDSU Building
Full-length roof.
Enclosed Parts Storage room(N/A with Genset Upgrade). Grasshopper mounting pedestal.
Articulated grasshopper-type cable tray system for support of theelectrical cables and hydraulic hoses between the TDSU and the rig floor.The grasshopper folds for transport on the TDSU.
Storage provision for the TDSU supply cables.
NOTE: The only required electrical interface to the rig is a 600 VAC supply to theTDSU. Additional control interfaces to the rig's power limit and mud pumpstatus are also recommended.
TDSU Weights and Dimensions
Weight Height Width Depth
Micro Building 13000 99" 120" 84"
with Land Configuration 40000 124" 480" 96"
53
-
8/10/2019 catalogo- ge752 . curvas.pdf
56/61
PRODUCT
INFORMATIONELECTRICAL AND HYDRAULIC
Electrical Interface Materials for TDSU Applications
1. Feeder Breaker Assembly (to supply 600 VAC power to the TDSU):
Feeder Breaker Enclosure, to be mounted at the rig'sSCR building,normally within 10 ft. of the 600 VAC bus.
Feeder Breaker.
Interface Power Cables - Rig Power Bus to Feeder Breaker:
Recommended maximum run length =10 ft.Run length supplied =20 ft.Bolted terminations both ends.
2. TDSU Supply Cables:
Standard run length =100 ft.
Additional run length available and price separately.
TDSU end terminations - Bolted; pre-terminated.
Feeder Breaker end terminations - Finney lugs; pre-terminated.
Typically the TDSU Supply Cables are integrated with the TDSU.
54
-
8/10/2019 catalogo- ge752 . curvas.pdf
57/61
PRODUCT
INFORMATIONELECTRICAL AND HYDRAULIC
Alternative electr ical power provis ionsin a stand alone configuration
Contro l and Interface PanelRequires DC power form dedicated SCR bay
This alternative is possible for new rigs or rigs with an existing SCR assignmentavailable for the top drive. This CIP proposal is conditional on the suitability ofthe existing SCR system.
1. Field Supply for the top drive, c/w static reversing and field weakening (3 levels).Requires a 480 or 600 V supply and 60-amp breaker.
2. Motor Controls for the HPU, blower and lube pump. Requires a 480 V powersupply and a 100-amp breaker.
3. Control Power Regulator4. Top drive control PLC with interface connections to the Transfer Contactors,
Field Supply and Motor Controls and interface terminations for connection to theSCR, the Top Drive Control Console and the Top Drive Unit.
5. Electrical interface engineering including interface documentation.6. Control cable and connectors from the CIP to the Top Drive Control Console.
Transfer Panel Unit (TPU)DC power from SCR bay, provides transfer function to allow same SCR to beswitched to other applications
This alternative is possible only for rigs with independent rotary table drive. ThisTPU proposal is conditional on the suitability of the existing SCR system.
For rigs without independent rotary drive or to minimize installation time andcost, we recommend an independent SCR bay for the top drive; see Item 7.
1. Transfer Contactors for assignment of the rig's existing SCR bridge to either thetop drive or the rotary table. The Transfer Panel will be located in a non-hazardous area.
2. Finney connections for the top drive and rotary table power cables.3. Field Supply for the top drive, c/w static reversing and field weakening (3 levels).
Requires a 480 or 600 V supply and 60-amp breaker.4. Motor Controls for the HPU, blower and lube pump. Requires a 480 V power
supply and a 100-amp breaker.5. Control Power Regulator.
55
-
8/10/2019 catalogo- ge752 . curvas.pdf
58/61
PRODUCT
INFORMATIONELECTRICAL AND HYDRAULIC
6. Top drive control PLC with interface connections to the Transfer Contactors,Field Supply and Motor Controls and interface terminations for connection to theSCR, the Top Drive Control Console and the Top Drive Unit.
7. Electrical interface engineering including interface documentation.8. Control cable and connectors from the Transfer Panel to the Top Drive Control
Console (Item 2).
Twin Hydraulic Power Unit (HPU)For auxiliary hydraulic functions
1. Twin, fully redundant, electrically driven hydraulic pumps, each 20 HP, 12GPM, 2500 PSI
2. Suction, pressure and return filtration3. Air to oil cooling system4. Stainless steel reservoir, 60 gallon5. Kidney loop cooling and filtration circulation system6. Temperature and oil level alarm sensors7. Unitized skid package c/w drip tray
56
-
8/10/2019 catalogo- ge752 . curvas.pdf
59/61
PRODUCT
INFORMATIONTOP DRIVE CONTROL CONSOLE
The Top Drive Control Consoleis the operating controls monitoringand display systems for drillersoperation of the Top Drive system.The console includes the following:
1. All control switches2. Emergency Stop and Lockout
controls.3. Top drive throttle4. RPM meter (digital)5. Torque meter (analog), scaled in
ft-lb or N-m6. Drilling Torque Limit control and meter7. Connection Torque Limit control and meter8. Smart calibration of the torque instrumentation and torque limit settings c/w
field level compensation.9. Status and alarm indicator lights10. Audible alarm11. Control PLC12. Stalled Motor Alarm and Unwind Control13. Connection Spin In/Out Control14. Connection Torque Control15. Drilling recorder signals for Torque and RPM, either 4-20 mA or 0-10 V.16. Connections for interface to the Control & Interface Panel17. Stainless steel purgeable enclosure.
57
-
8/10/2019 catalogo- ge752 . curvas.pdf
60/61
PRODUCT
INFORMATIONADVANCED DIAGNOSTICS SYSTEM
Canrigs Advanced Diagnostics System Screen
Communicates with the operator via a color monitor with touch sensitive screen torespond to messages and announcements. This Operator Interface Terminal alsoallows inputting correction factors and shutdown of non-essential functions tocontinue with strategic operations in case of an equipment failure.1. Messaging includes:
On-line help text, for quick access to operating and trouble shootinginstructions
Cable or connection failure of power or control cables
Presence of defective components identified to the sub assembly orindividual part.
Parameters out of adjustment with anticipated errors or deviations ofexpected results.
Incorrect sequence of operation with suggestion of how to achieveexpected results.
Auxiliary Mode
HelpScreen
RESET
BlownFuse
2H:MN NN/DD/YY
BUWOpen
UWCVOpen
ConsoleNormal
LinkTiltMaintain
HandlerBypassed
MotorStalled
HandlerForward
HPU HiTemp
BrakeON
TrqBoostDiseng.
LWCVOpen
TD LowHyd Pressure
Low Speed
FieldFault
SCRNormal
MCCBlown Fuse
Push to
CleanScreen
AckAll
s
t
58
-
8/10/2019 catalogo- ge752 . curvas.pdf
61/61
PRODUCT
INFORMATIONINSTALLATION AND CREW TRAINING
Installation, Start-up and On-site Crew Training Services
At the time of purchase, Canrig offers Top Drive Technicians at a flat rate for upto 35 man days including travel time for the initial Installation and Start-up.These technicians during the installation will provide crew training for:
Daily maintenanceOperation of equipmentBasic TroubleshootingRig up and rig down proceduresParts book review and parts ordering proceduresSupervise the installation and commissioning of the completesystem.
Training at the Canrig Manufacturing Facility
Canrig offers a variety of detailed training. Technical overview courses coverfunctionality of the Top Drive and its associated systems. Detailed courses areavailable which cover the Top Drives mechanical, hydraulic and electricalsystems as well as maintenance and service. Our classes also include partsbook familiarization and troubleshooting. Quality hands-on experience balancedwith an informal class setting is geared towards Top Drive operating andmaintenance personnel. Classes are usually from 2 to 5 days and safety isemphasized throughout our training programs