catalogue - ЭМИСemis-vekta vt200 insert pipes for installation use emis-vihr 200.kip cable kit...

52
CATALOGUE 2014 Group of industrial companies «EMIS» Flowmeters Measurement systems Metering skids Filters Associated equipment g skid skids d ed d k kids nt nt t nt n t e oc s o i at c t e oc c As s o ed e ed men m n equi pm eq pm i p t o o i at c t e oc c ed e e me n equi pm e pm i

Upload: others

Post on 02-Jan-2021

14 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

CATALOGUE

2014Group of industrial companies «EMIS»

www.emis-kip.ru

Flowmeters

Measurement systems

Metering skids

Filters

Associated equipment

454007, RUSS IA,

Che lyab insk , U l . Kommuny, 35 , off ice 13

Telephone: +7 (351) 729-99-12 (mul t ichanne l )

Fax : +7 (351) 729-99-13

E-mai l : sa les@emis -k ip . ru

EMIS Group Techn ica l Support Serv iceTe lephone: +7 (351) 729-99-12 (741)E-mai l : support@emis -k ip . ru

g skidskids

dedd

kkids

ntnttntnteocso iatc teoccAsso edeed menm nequipmeq pmiptoo iatc teocc ed ee menequipme pmi

Page 2: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,
Page 3: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 3Flow measurement and automatization

table of contents

floWSMART VORTEX FLOWMETER EMIS-VIHR 200 4

VORTEX FLOWMETER (FOR FORMATIOn pRESSuRE MAInTEnAnCE) EMIS-VIHR 200 ppD 6

InSERTIOn VORTEX FLOWMETER EMIS-VIHR 205 8

VORTEX BOREHOLE FLOWMETER EMIS-VIHR 200-SKV 10

pLASTIC ROTAMETER EMIS-META 210 11

METAL ROTAMETER EMIS-META 215 12

ELECTROnIC FLOWMETER FOR LIQuIDS EMIS-pLAST 220 14

ELECTROnIC FLOWMETER FOR LIQuIDS WITH InTEGRATED FLOW COnTROLLER EMIS-pLAST 220R 16

HIGH ACCuRACY ROTOR FLOWMETER FOR LIQuIDS EMIS-DIO 230 18

OVAL GEAR METER EMIS-DIO 230L 20

MASS FLOWMETER EMIS-MASS 260 22

MAGnETIC FLOWMETER EMIS-MAG 270 24

pADDLE TYpE FLOW SWITCH EMIS-pOTOK 236 27

THERMAL DISpERSIOn FLOW SWITCH EMIS-pOTOK 285 27

EMIS DEEp-WELL RESEARCH COMpLEX 29

EnERGY CARRIER METERInG SKID EMIS-ESKO 2210 30

METERInG SKID WITH SELF-COnTAInED pOWER SuppLY unIT EMIS-ESKO 2210-AIp 33

FLOW COnDITIOnERS / STRAIGHTEnERS EMIS-VEKTA 1200 34

LIQuID FILTERS EMIS-VEKTA 1210 35

GAS FILTERS EMIS-VEKTA 1215 37

FILTER-SEpARATOR EMIS-VEKTA 1212 38

InSERT pIpES EMIS-VEKTA VT 40

ORIFICE pLATES FOR FLOWMETERS DKS, DBS, DFK 41

LEVELInG VESSELS, SEpARATIOn VESSELS AnD COnDEnSInG VESSELS 42

PRessUReVALVE BLOCKS FOR pRESSuRE SEnSORS EMIS-VEKTA 1100 43

pRESSuRE REDuCInG VALVE EMIS-VEKTA 44

sYsteM coMPonentspuLSE pOWER SuppLY unIT EMIS-BRIZ 60 45

TRAnSFORMER pOWER SuppLY unIT EMIS-BRIZ 90 48

RS-485 InTERFACE COnVERTER EMIS-SYSTEMA 750 47

InTRInSIC SAFETY BARRIERS BIS-A-111-EX 47

seRVIcesSELECTIOn, EnGInEERInG, SupERVISInG InSTALLATIOn, InSTALLATIOn OF EMIS InSTRuMEnTS 48

VERIFICATIOn OF LIQuID FLOWMETERS 49

Page 4: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 4 http://www.emis-kip.ru/prod/ev200

sMaRt VoRteX floWMeteReMIs-VIHR 200

aPPlIcatIonsSuitable for commercial and industrial metering of associated petroleum gas, saturated and overheated steam, natural gas, compressed air, oxygen, hydrogen and other industrial gases. It is also used to measure the volume flow, water solutions and other liquids, including polluted liquids and different liquid compositions. Certificate of approval for almost all industries.

sPecIfIcatIonsprocess fluids ............................................... gas, steam, liquidsprocess fluid temperature ................................. -200°C to 460°Cprocess pressure ........................................................to 25Mpapipeline Dn .....................................................15mm to 300mmDynamic range...........................................................up to 1:46Accuracy (liquids) ........................................................... ±0,5%Accuracy (gas/steam) ..................................................... ±1,0%Output signals ............................1000Hz / 4-20mA /RS485/uSBExplosion proof .................. 1ExibIIB(T1-T5)X / 1ExibIIC(T1-T5)X/

1ExdIIC(T1-T5)X / РВ ExdIpower supply ................................................. 10V DC to 30V DCAmbient temperature ............................................. -50°C to 70°CWater and dust ignition-proof .............................................. Ip65Verification interval ......................................................... 4 years

featURes & adVantages• Wide dynamic range• High metrological stability of measurement• Stable work under high temperature • Low pressure loss• With no moving parts • Durable and reliable in service• Hydroblow resistant• Large amount of maintenance works are not required• permits remote data communication, configuration, testing

through RS-485 Modbus RTu • Flow-calibrated on liquid flow test stand• Explosion proof pB ExdI• «Simulation» diagnostics are available

oPtIonal sPecIfIcatIonsItem description

EMIS-VIHR 200.CK Connection kit (cast steel flanges, gaskets, bolts, stud bolts, screw nuts, washers)

EMIS-VIHR 200.CK-n Connection kit (stainless steel flanges, gaskets, bolts, stud bolts, screw nuts, washers)

EMIS-VEKTA VT200 Insert pipes for installation use

EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs

EMIS-BRIZ power supply unit

floW Ranges*dn, mm liquids, m3/h gas/steam, m3/h

15 0,2–5 3,2–32

25 0,4–16 3,5–120

32 0,6–26 6–200

40 1–41 9–310

50 1,4–64 14–480

65 2,6–107 24–810

80 4–160 36–1230

100 6–250 60–1920

125 10–400 90–3000

150 14–575 130–4325

200 26–1060 235–8000

250 42–1700 380–12900

300 60–2460 550–18600

* – the lower limit of gas and steam flow depends on operating conditions. Flow ranges are specified for maximum process temperature 100°С.

eMIs-VIHR 200

To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please.!Attention!

Page 5: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 5 http://www.emis-kip.ru/prod/ev200

eMIs-VIHR 200

oRdeRIng InfoRMatIon

code 0 1 2 3 4 5 6 7 8 9 10 11 12 13

order eMIs-VIHR 200 - Vn - 050 - a - - - Zh - H - fR - - - 2,5 - 250 - - - a - gP

tHe eXaMPle of tHe oRdeR:eMIs-VIHR 200-Vn-050-a-ZH-Н-fR-2,5-250-a-gP (eMIs-VIHR 200. cK)Integral type (sensor and electronic converter are mounted together)Vortex flow converter EMIS-VIHR 200, flameproof enclosure 1ExdIIC(T1-T5)X, reducer type Dn =50 mm, measurement accuracy 0,5%, process fluid - liquids, process-wetted material is stainless steel, maximum process pressure up to 2,5Mpa, process fluid temperature from -40 to +250 °С, with optional analog output signal, verified, connection kit made of cast steel.

1 type of explosion protection standard*- Without explosion protection (standard)

ExB Explosion-proof class 1ExibIIB (T1-T5)X ExC Explosion-proof class 1ExibIIC (T1-T5)X (special order)Vn Flameproof enclosure 1ExdIIC(T1-T5)X pB Explosion proof pB ExdI

X Special order2 nominal diameter

015 Dn = 15 mm (only for 100 °С) 100 Dn=100mm

025 Dn=25mm 125 Dn=125mm

032 Dn=32mm 150 Dn=150mm

040 Dn=40mm 200 Dn=200mm

050 Dn=50mm 250 Dn=250mm

065 Dn=65mm 300 Dn=300mm

080 Dn=80mm X Special order 3 accuracyA Class A(nominal accuracy for liquids ± 0,5%, for gas and steam ± 1,0%)B Class B(nominal accuracy for liquids ± 1,0%, for gas and steam ± 1,5%)

4 flow range- Standard, according to user Manual

X Specail order5 Process fluid

Zh Liquid

G Gas, saturated steam, overheated steam

K OxygenX Special order6 Process-Wetted Materials H Stainless steel

Xc Hastelloy analogueX Special order7 Pipeline connectionsS Wafer type (Dn from 15 to 100 mm)

F Flange type

FR Flanged Reducer type (Dn from 25 to 100 mm)X Special order8 electronic transmitter type - Integral type (sensor and electronic transmitter are mounted together)

D Remote type electronic transmitter (cable length 3 m) DXX Remote type electronic transmitter (with customer-specified cable length, for example, R08)

X Special order9 Process fluid pressure

1,6 Maximum pressure – up to 1,6 Mpa

2,5 Maximum pressure – up to 2,5 Mpa

4,0 Maximum pressure – up to 4,0 Mpa6,3 Maximum pressure – up to 6,3 Mpa20 Maximum pressure – up to 20 Mpa25 Maximum pressure – up to 25 Mpa

X Special order (up to 25 Mpa)

10 Process fluid temperature50 -200 to+50 °С (special order) 320 -40 to +320 °С

100 -40 to +100 °С 460 -40 to +460 °С250 -40 to +250 °С X Special order11 digital display - Without display

CI Digital display with basic optionsX Special order

12 output signals- pulse output signal 0…1000 Hz and digital output signal RS-485

A Optional analog output signal 4–20 mA

X Special order13 calibration, verification- 5 points factory calibration, pressure test (for technological needs)

Gp Verification (for fiscal metering)

* «» - positions represents the most common options with the best delivery time.

Page 6: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 6

oPtIonal sPecIfIcatIons

Item description

EMIS-VIHR 200-ppD.CKConnection kit (cast steel flanges, stud bolts, screw nuts)

EMIS-VIHR 200-ppD.CK-nConnection kit (stainless steel flanges, stud bolts, screw nuts)

EMIS-VEKTA VT200 Insert pipes for installation use

EMIS-VIHR 200.KIp Cable kit for simulation diagnostic use

EMIS-BRIZ power supply unit

http://www.emis-kip.ru/prod/ev200

floW Ranges

dn/ maximum flow

Water flow, m3/h

operation range full range

Qmin’ Qmax’ Qmin Qmax

50/10 0,3 8 0,2 1050/20 0,7 20 0,5 2550/35 1 35 0,7 4050/60 1,5 60 1 6580/20 0,6 20 0,4 2580/35 1 35 0,7 4080/50 1,6 50 1 60

80/150 4 150 2,5 160100/25 1 25 0,8 32100/50 2 50 1,25 55

100/200 8 200 6 220100/300 12 300 10 330

ppD transmitter process pressure value should not be less than:0,3Mpa – for Q≤Qmin’;0,4Mpa – for Qmin’<Q≤0,5•Qmax’;0,8Mpa – for Q>0,5•Qmax’.

To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please.!Attention!

VoRteX floWMeteR (foR foRMatIon PRessURe MaIntenance) eMIs-VIHR 200 PPd

aPPlIcatIonsppD flowmeters are used to measure the volume flow of water injected into the reservoir during oil production to support pressure of the reservoir, to measure the flow of Cenomanian water and other liquids transmitted under high pressure. EMIS-VIHR ppD observes maximum process pressure requirements, requirements for gas, mechanical and other kinds of fluid pollution.

featURes & adVantages• Wide dynamic range• Standard mounting dimensions and flow rate allow to replace any

other flowmeter used in water injection systems • Measures polluted and gaseous liquids• Durable and reliable in service• Wide range of nominal sizes• Regular maintenance is not required• permits remote data communication, configuration, testing

through RS-485 Modbus RTu • «Simulation» diagnostics are available

sPecIfIcatIonsprocess fluids ............................................................... liquidsMechanical impurity ................................................ up to 20g/lGaseous impurities ...................................................up to 15%process temperature limits ................................. -40°C to 100°Cpressure limits ......................................................up to 25MpaDynamic range.........................................................up to 1: 64Accuracy ......................................................................±1,0%Output signals ...................................1000Hz / 4-20mA /RS485Explosion proof .............................................. 1ExibIIC(T1-T5)XAmbient temperature ............................................ -50°C to 70°CWater and dust ignition-proof .............................................Ip65Verification interval ........................................................4 years

eMIs-VIHR 200 PPd

Page 7: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 7http://www.emis-kip.ru/prod/ev200

High pressure vortex flowmeter EMIS-VIHR 200 PPD on the test stand

High pressure vortex fliowmeter EMIS-VIHR 200 PPD on-the-spot

oRdeRIng InfoRMatIon

1 dn / flow range code

50/10 Dn=50mm, flow range code 10

50/20 Dn=50mm, flow range code 20

50/35 Dn=50mm, flow range code 35

50/60 Dn=50mm, flow range code 60

80/20 Dn=80mm, flow range code 20

80/35 Dn=80mm, flow range code 35

80/50 Dn=80mm, flow range code 50

80/150 Dn=80mm, flow range code 150

100/25 Dn=100mm, flow range code 25

100/50 Dn=100mm, flow range code 50

100/200 Dn=100mm, flow range code 200

100/30 Dn=100mm, flow range code 300

X Special order

2 accuracy (see table 1.6)

- Class B (nominal accuracy ± 1,5% is allowed)

A Class A (nominal accuracy ± 1% is allowed)

3 Maximum process pressure

- up to 25Mpa (standard)

20 up to 20Mpa

4 calibration, verification

- 5 points factory calibration, pressure test

Gp Verification

tHe eXaMPle of tHe oRdeR:eMIs-VIHR 200-PPd-100/50-gP (eMIs-VIHR 200-PPd.cK)Integral type (sensor and electronic transmitter are mounted together) Vortex flowmeter EMIS-VIHR 200-ppD, flameproof enclosure 1ExdIIC(T1-T5)X, Dn=100, flow range code 50, measurement accuracy is 1,5%, maximum process pressure up to 25Mpa, process fluid temperature from -40 to +100 °С, with pulse, digital and current output signal, verified, connection kit made of cast steel.

eMIs-VIHR 200 PPd

Page 8: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 8

eMIs-VIHR 205

http://www.emis-kip.ru/prod/ev205

InseRtIon VoRteX floWMeteR

eMIs-VIHR 205

aPPlIcatIonsSuitable for commercial and industrial metering of liquids, gas and steam. pipeline Dn 200 mm to 2000 mm. Certificate of approval for almost all industries.

featURes & adVantages• Easy installation • no need to stop flow*• no moving parts • Durable and reliable in service• Maintenance works are not required• Only flow sensor requires water testing• Accuracy is not related to process parameter changes

* For process pressure 1,6 MPa.

floW Ranges*dn, mm liquids, m3/h gas/steam, m3/h

200 29–570 320–4410

250 45–880 500–7070

300 66–1270 710–10180

350 90–1730 970–13850

400 120–2260 1260–18100

450 150–2860 1600–22900

500 185–3540 1980–28260

600 265–5090 2850–40700

700 360–6920 3880–55400

800 470–9040 5060–72350

900 595–11450 6400–91560

1000 735–14140 7900–113040

1100 890–17110 9580–136780

1200 1060–20360 11400–162780

1300 1240–23900 13370–191040

1400 1440–27700 15500–221560

1500 1650–31800 17800–254340

1600 1880–36200 20260–289380

1800 2380–45800 25640–366250

2000 2940–56550 31650–452160

oPtIonal sPecIfIcatIons

Item description

BV Ball valve

EMIS-BRIZ power supply unit

Insertion equipment Equipment for “non-stop flow” insertion*

* For process pressure 1,6MPa.

DN – pipeline nominal diamete.

sPecIfIcatIonsprocess fluids ....................................................gas, steam, liquidsprocess temperature limits .......................................-40°C to 250°Cpressure limits .......................................................... up to 4,0Mpapipeline Dn ..................................................... 200mm to 2000mmDynamic range....................................................................... 1:27Accuracy (liquids................................................................. ±1,5%Accuracy (gas/steam .......................................................... ±2,5%Output signals ........................................ 1000Hz / 4-20mA /RS485Explosion proof .......................1ExibIIB(T1-T5)X / 1ExibIIC(T1-T5)X/

1ExdIIC(T1-T5)Xpower supply ......................................................10V DC to 30V DCAmbient temperature ................................................. -40°C to 70°CWater and dust ignition-proof .................................................. Ip65Verification interval ............................................................. 4 years

Page 9: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 9http://www.emis-kip.ru/prod/ev205

eMIs-VIHR 205

oRdeRIng InfoRMatIon

code 0 1 2 3 4 5 6 7 8 9 10 11 12

order eMIs-VIHR 205 - Vn - 400 - a - - - Zh - n - - - 1,6 - 250 - - - - - gP

tHe eXaMPle of tHe oRdeR:eMIs-VIHR 205-Vn-400-a-ZH-n-1.6-250-gPIntegral type (sensor and electronic transmitter are mounted together) submersible Vortex flowmeter EMIS-VIHR 205, explosion proof 1ExdIIC(T1-T5)X, pipeline Dn Dn =400 mm, measurement accuracy 1,5%, process fluid - liquids, maximum process pressure up to 1.6Mpa, process fluid temperature from -40 to +250 °С, verified.

1 type of explosion protection standard*

- Without explosion protection (standard)

ExB Explosion-proof class 1ExibIIB (T1-T5)X

ExC Explosion-proof class 1ExibIIC (T1-T5)X

Vn Explosion-proof enclosure 1ExdIIC(T1-T5)X

X Special order

2 nominal diameter

200 - 2000 Dn=200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300, 1400, 1500, 1600, 1800, 2000 mm

X Special order

3 accuracy

A Class A(nominal accuracy for liquids ± 1,5%, for gas and steam ± 2,5% is allowed)

B Class B(nominal accuracy for liquids ± 2,0%, for gas and steam ± 3,0% is allowed)

4 flow range

- Standard

X Special order

5 Process fluid

Zh Liquid

G Gas/ saturated steam/ overheated steam

X Special order

6 Process-Wetted Materials

n Stainless steel (standard)

X Special order

7 electronic transmitter type

- Integral type (sensor and electronic transmitter are mounted together)

D Remote type electronic transmitter (cable length 3 m)

DXX Remote type electronic transmitter (with customer-specified cable length, for example, R08)

X Special order

8 Maximum fluid pressure

1,6 Maximum pressure – to 1,6 Mpa (standard)

2,5 Maximum pressure – 2,5 Mpa

4,0 Maximum pressure – to 4,0 Mpa

X Special order

9 Process fluid temperature

100 -40 to +100 °С

250 -40 to +250 °С

X Special order

10 digital display

- Without display

SI Digital display with basic options

X Special order

11 output signals

- pulse output signal 0…1000 Hz and digital output signal RS-485

A Optional analog output signal 4–20 mA

X Special order

12 calibration, verification

- 5 points factory calibration, pressure test (for technological needs)

Gp Verification (for fiscal metering)

* «» - positions represents the most common options with the best delivery time.

Page 10: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 10

eMIs-VIHR 200-sKV

http://www.emis-kip.ru/prod/skv

VoRteX boReHole floWMeteR

eMIs-VIHR 200-sKVaPPlIcatIonsEMIS-VIHR 200-SKV is up-to-date solution for permanent monitoring of oil and water-injection wells. Flowmeter should be installed on production string. This equipment provides high accuracy of current flow and well discharge. High reliability, thermal and pressure resistance and protection from measuring fluids influences allow to use this flowmeter in the most difficult conditions.

featURes & adVantages• unique Well parameter Control System, no analogues on the

market • Vortex type• permanent monitoring of well parameters• With no moving parts• Corrosion-resistant, material – stainless steel• Durable and reliable in service• High thermal and pressure resistance• Data transmission to high level of process Control System

(pCS)

eMIs deep-well research complex based on vortex borehole flowmeter eMIs-VIHR 200-sKV – see page 29.

oRdeRIng InfoRMatIon

flowmeter versionflow range, m3/day

Qmin

Qmax

EMIS-VIHR 200-SKV-020 4,7 190

EMIS-VIHR 200-SKV-036 12,5 500

To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please.Flowmeters can be delivered separately or in oil well systems. For more details, please contact our sales department.

sPecIfIcatIonsprocess fluids ..................................................... oil, layer, wateprocess temperature and ambient temperature limits ....-20°C to 110°Cpressure limits ....................................................... up to 50MpaDynamic range.................................................................. 1: 17Accuracy ....................................................................... ±1,5%Output signals .............pulse signal/Modbus/Manchester code-IIExplosion proof ........................................................ 1ExdIIAT4Xpower supply ................................................. 12V DC to 30V DCWater and dust ignition-proof .............................................. Ip68Verification interval ......................................................... 4 years

!Attention!

Page 11: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 11http://www.emis-kip.ru/prod/em210

eMIs-Meta 210

PlastIc RotaMeteR

eMIs-Meta 210aPPlIcatIonsSuitable to measure the low volume flow of liquids and gases. Their main application field is water purging and water treatment, moreover it is used in chemical, oil, food, pulp and paper industries and medicine. EMIS-META 210R has integrated flow regulator that is why it can be used to control the flow.

featURes & adVantages• Directly read flow value• Minimum work during installation• Doesn’t require any settings before installation• Flow regulator• Durable and reliable in service• Stable work

VeRsIons

Indexdn, mm

type*flow rate, m3/h

min maxflow rate of liquidsЕМ 210-008А-Zh 8

0,002 0,02ЕМ 210-008B-Zh 8 0,004 0,04ЕМ 210-008V-Zh 8 0,006 0,06ЕМ 210-008G-Zh 8 0,01 0,1ЕМ 210-010А-Zh 10

pR10,03 0,24

ЕМ 210-010B-Zh 10 0,06 0,42ЕМ 210-010V-Zh 10 0,12 1,08ЕМ 210-010G-Zh 10

pА0,03 0,24

ЕМ 210-010D-Zh 10 0,06 0,42ЕМ 210-010Е-Zh 10 0,12 1,08ЕМ 210-015А-Zh 15

pR2

0,016 0,16ЕМ 210-015B-Zh 15 0,025 0,25ЕМ 210-015V-Zh 15 0,04 0,4ЕМ 210-015G-Zh 15 0,06 0,6ЕМ 210-025А-Zh 25

pR20,16 1,6

ЕМ 210-025B-Zh 25 0,25 2,5ЕМ 210-025V-Zh 25

pR10,3 2,1

ЕМ 210-025G-Zh 25 0,24 3,6ЕМ 210-025D-Zh 25 0,6 4,2ЕМ 210-025Е-Zh 25

pА0,3 2,1

ЕМ 210-025Zh-Zh 25 0,24 3,6ЕМ 210-025Z-Zh 25 0,6 4,2ЕМ 210-032А-Zh 32

pR20,4 4

ЕМ 210-032B-Zh 32 0,6 6ЕМ 210-040А-Zh 40

pR1

0,9 9ЕМ 210-040B-Zh 40 1,5 15ЕМ 210-040V-Zh 40 1,8 18ЕМ 210-040G-Zh 40 3 21ЕМ 210-050А-Zh 50

pR21 10

ЕМ 210-050B-Zh 50 1,6 16ЕМ 210-065А-Zh 65

pR25 25

ЕМ 210-065B-Zh 65 8 40ЕМ 210-065V-Zh 65 12 60ЕМ 210-100А-Zh 100

pR216 90

ЕМ 210-100B-Zh 100 18 120ЕМ 210-100V-Zh 100 25 200ЕМ 210-125А-Zh 125

pR216 90

ЕМ 210-125B-Zh 125 18 120ЕМ 210-125V-Zh 125 25 200ЕМ 210-150А-Zh 150

pR216 90

ЕМ 210-150B-Zh 150 18 120ЕМ 210-150V-Zh 150 25 200

Indexdn, mm

type*flow rate, m3/h

min maxadjustable flow rate of liquidsЕМ 210-Р-008А-Zh 8

0,002 0,02ЕМ 210-Р-008B-Zh 8 0,004 0,04ЕМ 210-Р-008V-Zh 8 0,006 0,06ЕМ 210-Р-008G-Zh 8 0,01 0,1ЕМ 210-Р-010А-Zh 10

pА0,03 0,24

ЕМ 210-Р-010B-Zh 10 0,06 0,42ЕМ 210-Р-010V-Zh 10 0,24 1,08ЕМ 210-Р-025А-Zh 25

pА0,3 2,1

ЕМ 210-Р-025B-Zh 25 0,24 3,6ЕМ 210-Р-025V-Zh 25 0,6 4,2flow rate of gasЕМ 210-010V-G 10

pА2,88 28,8

ЕМ 210-010G-G 10 4,32 43,2ЕМ 210-025А-G 25

pА7 70

ЕМ 210-025B-G 25 10 100adjustable flow rate of gasЕМ 210-R-008А-G 8

0,03 0,3ЕМ 210-R-008B-G 8 0,06 0,6ЕМ 210-R-008V-G 8 0,12 1,2ЕМ 210-R-008G-G 8 0,24 2,4ЕМ 210-R-008D-G 8 0,3 3ЕМ 210-R-008Е-G 8 0,6 6ЕМ 210-R-010А-G 10

0,72 7,2ЕМ 210-R-010B-G 10 1,44 14,4ЕМ 210-R-010V-G 10 2,88 28,8ЕМ 210-R-010G-G 10 4,32 43,2ЕМ 210-R-025B-G 25 pА 10 100

*PR1, PR2 – straight through type, PA – panel type

sPecIfIcatIonsLiquid flow rate ............................................... 0,002 – 200 m3/hGas flow rate ..................................................... 0,03 – 100 m3/hAccuracy ...........................................................................±4%Repeatability ................................................................ ±0,25%process pressure limits ....................................... 100pa to 1MpaViscosity ....................................................................... 5mpa*sprocess temperature ................................................ -20 to 80°CConnection thread material .............................. plastic ABS, pVCMeasuring mechanism material ............................ stainless steelRotameter material .........................................................pMMAAmbient temperature ................................................ -40 to 70°C

Page 12: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 12

http://www.emis-kip.ru/prod/em215

eMIs-Meta 215

Metal RotaMeteR

eMIs-Meta 215

aPPlIcatIonThe main difference between metal rotameter and plastic or glass is that metal one can be used for high pressure and high temperature applications. EMIS-META 215 rotameter measurement accuracy is high, it is easy to install, provides flow conversion to standard current signal 4 – 20 mA or to HART digital signal. It is not only measures volume flow, but also can totalize and display accumulated flow value.

featURes & adVantages• Simple design• High accuracy• Durable and reliable in service• Measures aggressive(corrosive) fluids• Integrated digital display• Stable under high pressure and temperature conditions• Integrated alarm system• Easy to check and calibrate

sPecIfIcatIonsFlow rate of liquids ............................................2,5 – 100000 l/hFlow rate of gas ............................................... 0,07 – 3000 m3/hnominal diameter .................................................15 to 150 mmOutput signals and indication .... LCD display / analog current signal

4-20mA / HART / one or two limit switchesAccuracy .................................................................1,5%, 2,5%process pressure .................................................. up to 10 Mpaprocess temperature ........................................... -80°C to 250°CAmbient temperature ............................................. -25°C to 55°CWater and dust ignition-proof .............................................. Ip65Explosion proof ........................... 1ExibIIBT2/T4, 1ExdibIIBT2/T4power supply .................................................................24V DCConnection type ...................................flange / coupling /fixtureVerification interval ......................................................... 5 years

oPtIonal sPecIfIcatIonsItem description

EMIS-META 215. CK Connection kit (flange, gaskets, metalware)

Magnetic filter Cleans mechanical contamination from fluid

HART modem provides data communication through HART protocol

EMIS-BRIZ power supply unit

EMIS-VEKTA VT.215 Insert pipes for installation use

dn, mm

flow rangersWater, l/h

gas, m3/hstainless steel (n)

teflon (ft)

015А 2,5–25 – 0,07–0,7015B 4–40 2,5–25 0,11–1,1015V 6,3–63 4–40 0,18–1,8015G 10–100 6,3–63 0,28–2,8015D 16–160 10–100 0,48–4,8015E 25–250 16–160 0,7–7,0

015Zh 40–400 25–250 1,0–10015I 63–630 40–400 1,6–16025А 100–1000 63–630 3–30025B 160–1600 100–1000 4,5–45025V 250–2500 160–1600 7–70025G 400–4000 250–2500 11–110040А 500–5000 400–4000 12–120040B 600–6000 500–5000 16–160050А 630–6300 600–6000 18–180050B 1000–10 000 630–6300 25–250050V 1600–16 000 1000–10 000 40–400080А 2500–25 000 1600–16 000 60–600080B 4000–40 000 2500–25 000 80–800100 6300–63 000 4000–40 000 100–1000150 20 000–100 000 – 600–3000

delIVeRY KIt

№ Item amount, pcs

1 Metal rotameter 1

2 Certificate 1

3 user manual 1

To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please.

floW Ranges

http://www.emis-kip.ru/prod/em215

!Attention!

Page 13: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 13http://www.emis-kip.ru/prod/em215

eMIs-Meta 215

oRdeRIng InfoRMatIoncode 0 1 2 3 4 5 6 7 8 9 10 11 12 13

order eMIs-Meta 215 - - - 050 - b - Zh - n - - - 1,6 - 100 - 1,5 - t - a - - gP

tHe eXaMPle of tHe oRdeR:eMIs-Meta 215-050-400-b-Zh-n-1,6-100-1,5-t-a (eMIs-Meta 215.cK)Rotameter EMIS-META 215 with intrinsically-safe circuit, pipeline Dn Dn =50 mm, process fluid - liquids, maximum process pressure up to 1.6Mpa, process-wetted material – stainless steel, process fluid temperature from -40 to +100 °С, with heating module, accuracy 1,5%, analog output signal, without LCD-display, with connection kit, verified.

1 type of explosion protection- Without explosion protection

Ex 1ExibIIBT2/T4 – intrinsically-safe circuit Vn 1ExdIIC(T1-T5)X – explosion-proof enclosure and intrinsically-safe circuitX Special order2 nominal diameter

015 Dn=15mm 080 Dn=80mm025 Dn=25mm 100 Dn=100mm040 Dn=40mm 150 Dn=150mm050 Dn=50mm X Special order

3 flow range*A Flow range A E Flow range EB Flow range B Zh Flow range ZhV Flow range V I Flow range IG Flow range G X Special orderD Flow range D

* According to the special order we can produce rotameters with individual flow ranges. In this case, please tell us your requirements for flow range and put «X» after diameter code (see the example of the order).

4 Process fluid*Zh LiquidG GasX Special order

* Generally our rotameters are calibrated to be used under normal conditions (hereinafter referred as to NC). Normal conditions are:• Liquid – water at 20°C;• Gas – air at 20°C and 0,1013MPaIf you need to change the process fluid that is different to NC, please indicate it in your order.

5 Process-Wetted Materials n Stainless steel (SS304)Ft Teflon (pTFE)X Special order6 Pipeline connections*- Flange

M Coupling, screw thread SMS1146Z Fixture X Special order

* M and Z type is not available in Teflon (Ft process-wetted material)7 Process pressure

1,6 Maximum pressure – 1,6 Mpa2,5 Maximum pressure –2,5 Mpa4,0 Maximum pressure – 4,0 Mpa10 Maximum pressure – 10,0 MpaX Special order8 Process fluid temperature

100 -40°C to 100 °С250* -80°C to 250 °С

X Special order* Is not available in Teflon (Ft process-wetted material) and with M and Z pipeline connections.

9 accuracy 2,5 Accuracy class 2,51,5 Accuracy class 1,5X Special order

10 thermal jacket - Without thermal jacketT Thermal jacket for heating rotameter body by steam or oil

11 output interface- Without interface A Analog output interface 4 – 20 mA

H* HART™+analog output interface 4 – 20 mApV1 One limit switchpV2 Two limit switchers

X Special order12 optional lcd-display - Without display

Zh* LCD-display* LCD-display is available only for rotameters with output signal type A and H. H-type output signal rotameters are always equipped with LCD-display.

13 calibration, verification- Factory calibration, pressure test (for technological needs)

Gp Verification

Page 14: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 14 http://www.emis-kip.ru/prod/ep220

eMIs-Plast 220

electRonIc floWMeteR foR lIQUIds

eMIs-Plast 220aPPlIcatIonsFor high pressure line applications to measure the volume and volume flow of liquids, for process data communications and accountings. Electronic flowmeters EMIS-pLAST 220 are used in numerous branches of industry such as petroleum, chemical, petrochemical, metal industry and in public facilities.

sPecIfIcatIonsnominal diameter ..............................................8mm to 300mmVibration limits ........................................... frequency 10-55Hz /

maximum acceleration amplitude: 19,6m/s2

Output signals ............................ pulse / 4-20 mA / Modbus RTuMaximum process pressure ................................... up to 42 Mpaprocess temperature limits ..................................... 0°C to 150°CAmbient temperature ............................................. -40°C to 50°CExplosion proof ..........................................1ExdIIBT4X / pB ExdlWater and dust ignition-proof .............................................. Ip65power supply ...............................24V DC or 3,6V integral battaryVerification interval ......................................................... 4 yearsViscosity .................................................................... up to 5 cpConnection type ............................................................. flange

oPtIonal sPecIfIcatIons

VeRsIons

Item description

EMIS-pLAST 220.CK Connection kit (flange, gaskets, bolts, screw nuts, washers)

EMIS-VEKTA VT220 Insert pipes for installation use

EMIS-BRIZ power supply unit

dn, mmflow range, m3/h, depending on accuracy

0,5% 1% 1,5% 2,5%008 0,1–0,5 0,15–0,7 0,1–0,8 0,08–0,8015 0,15–0,75 0,2–1 0,15–1,5 0,12–1,5020 0,3–0,5 0,3–1,5 0,3–3 0,2–4025 1–5 1–5 0,6–6 0,5–7040 3–15 3–15 2–15 1,5–15050 4–20 4–20 2,5–25 2–25065 – 6–50 5–50 4–50080 – 10–80 10–100 6–100100 – 30–200 20–200 18–250150 – 50–300 40–400 30–400200 – 100–500 60–600 70–700250 – 200–1000 150–1500 120–1500300 – 300–1500 250–2000 150–2000

MateRIals• Generally we recommend to choice meter body and flanges made of cast steel.• For corrosive fluid applications or in case of special requirements for hygiene, you should choice meter body and flanges made of stainless

steel (n version).

code Process-wetted part Primary transducer applications

Standard Straight Teflon-coated impeller

polluted liquids, water with oil and mechanical pieces est. u Angular

featURes & adVantages• Flow measurement under high pressure• non-clog design• Suitable for corrosive fluids• Stable work under high pressure• Explosion proof 1ExdllBT4X and pB Exdl are available

floW Range

To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please.!Attention!

Page 15: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 15

eMIs-Plast 220

http://www.emis-kip.ru/prod/ep220

oRdeRIng InfoRMatIon

code 0 1 2 3 4 5 6 7 8 9 10 11 12

order eMIs-Plast 220 - Vn - - - 050 - - - n - 6,3 - 80 - - - 1 - - - fR - gP

tHe eXaMPle of tHe oRdeR:eMIs-Plast 220-Vn-050-n-6,3-80-1-fR-gP (eMIs-Plast 220.cK)Electronic flowmeter for liquids EMIS-pLAST 220 STAnDART with explosion proof 1ExdllBT4X, flanged reducer type Dn=50mm, process-wetted material – stainless steel, maximum process pressure up to 6,3Mpa, measurement accuracy 1%, process temperature range 0°C to 80°C, pulse and digital output signals, with connection kit.

1 type of explosion protection

- Without explosion protection

Vn Explosion-proof class 1ExdllBT4X

pB Explosion-proof class pB Exdl

X Special order

2 Version

- Standard version

u Angular version

X Special order

3 nominal diameter

008 Dn = 8 мм 080 Dn = 80 мм

015 Dn = 15 мм 100 Dn = 100 мм

020 Dn = 20 мм 150 Dn = 150 мм

025 Dn = 25 мм 200 Dn = 200 мм

040 Dn = 40 мм 250 Dn = 250 мм

050 Dn = 50 мм 300 Dn = 300 мм

065 Dn = 65 мм Х Special order

4 flow range

- Standard, according to uM

X Specail order

5 Process-Wetted Materials

ST Cast steel

n Stainless steel (standard)

X Special order

6 Process fluid pressure

1,6 Maximum pressure – 1,6 Mpa 16,0 Maximum pressure – 16,0 Mpa

2,5 Maximum pressure – 2,5 Mpa 25,0 Maximum pressure – 25,0 Mpa

4,0 Maximum pressure – 4,0 Mpa 42,0 Maximum pressure – 42,0 Mpa

6,3 Maximum pressure – 6,3Mpa X Special order

7 Process fluid temperature

80 0 to 80 °С

150 0 to 150 °С

X Special order

8 output signals

- pulse output signal and digital output signal Modbus RTu

A Optional current output signal (4–20 mA)

X Special order

9 accuracy

0,5 0,5%

1 1%

1,5 1,5%

2 2%

X Special order

10 digital display

- Digital display with basic options

X Special order

11 Pipeline connection

- Flange

FR Flanged reducer type

X Special order

12 calibration, verification

- Factory calibration, pressure test (for technological needs)

Gp Verification (for fiscal metering)

Page 16: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 16 http://www.emis-kip.ru/prod/ep220

eMIs-Plast 220R

electRonIc floWMeteR foR lIQUIds

WItH IntegRated floW contRolleR eMIs-Plast 220R

aPPlIcatIonsThis is unique solution that includes flowmeter for liquids, valve and controller.Suitable for automatic measurement and control system and dosing system applications. Widely used in reservoir pressure maintenance systems and in oil wells for water and oil water interface measurement.Mechanical pollution protection and oil protection allow to use this flowmeter for waste water applications.

featURes & adVantages• Self-contained power supply• Self-contained and manual flow control valve• Space effective• Wireless digital interface• Cost-effective flow control system• Doesn’t require extra setting

PRIncIPle of oPeRatIonCustomer through push-button operation or remote through the interface set the flow rate. During operation process controller regulate valve position to maintenance the flow level. Manual control is also available, that allows to use flowmeter in dosing systems effectively and provides flow control in case of power failure situations.

sPecIfIcatIonsDn .................................................................. 15 mm to 80 mmAccuracy .....................................................................up to 1%Flow level stability ................................................................1%Output signals ..............................pulse / 4-20mA /Modbus RTuMaximum process pressure ................................... up to 16 Mpaprocess temperature ........................................... -20°C to 150°CAmbient temperature ............................................... -40° to 55°CExplosion proof ........................................................1ExdIIBT4XWater and dust ignition-proof .............................................. Ip65power supply ...............3,6 V integral battery / 24 V DC / 220 V ACConnection type ............................................................flangedVerification interval ......................................................... 4 yearsViscosity .................................................................... up to 5 sp

oPtIonal sPecIfIcatIons

Item description

EMIS-pLAST 220.CK Connection kit (flange, gaskets, bolts, screw nuts, washers)

EMIS-VEKTA VT220R Insert pipes for installation use

EMIS-VIHR 200.KIp Cable kit for simulation diagnostic use

EMIS-SYSTEMA 750 RS-485 converter

EMIS-BRIZ power supply unit

dn, mmfull range, m3/h, depending on accuracy

1% 1,5% 2,5%

015 0,2–1 0,15–1,5 0,12–1,5

020 0,3–1,5 0,3–3 0,2–4

025 1–5 0,6–6 0,5–7

040 3–15 2–15 1,5–15

050 4–20 2,5–25 2–25

DN – pipeline nominal diameter of pipeline, mm.If pipeline DN and meter DN are not match together, conical adapters can be used. Centre angle of adapter can’t be more than 30°.

floW Ranges

To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please.!Attention!

Page 17: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 17http://www.emis-kip.ru/prod/ep220

eMIs-Plast 220R

oRdeRIng InfoRMatIon

code 0 1 2 3 4 5 6 7 8 9 10 11 12

order eMIs-Plast 220 - - - R - 050 - - - n - 6,3 - 80 - - - 1 - - - fR - gP

tHe eXaMPle of tHe oRdeR:eMIs-Plast 220r-Vn-R-050-n-6,3-80-a-1-fR-gP (eMIs-Plast 220.cK)Electronic flowmeter for liquids EMIS-pLAST 220R with controller, flanged reducer type Dn=50mm, process-wetted material – stainless steel, maximum process pressure up to 6,3Mpa,process temperature range -20°C to 80°C, measurement accuracy 1%, pulse and digital output signals, with connection kit.

1 type of explosion protection

- Without explosion protection

Vn Explosion-proof class 1ExdllBT4X

X Special order

2 Version

- Standard version

u Angular version

X Special order

3 nominal diameter

015 Dn = 15 mm

020 Dn = 20 mm

025 Dn = 25 mm

040 Dn = 40 mm

050 Dn = 50 mm

Х Special order

4 flow range

- Standard, according to 1.3.2

X specail order

5 Process-Wetted Materials

ST Cast steel

n Stainless steel

X Special order

6 Process fluid pressure

1,6 Maximum pressure – 1,6 Mpa 6,3 Maximum pressure –6,3Mpa

2,5 Maximum pressure –2,5 Mpa 16 Maximum pressure –16,0 Mpa

4 Maximum pressure –4,0 Mpa X Maximum pressure –42,0 Mpa

7 Process fluid temperature

80 -20°C to 80 °С

150* 0 to 150 °С

X Special order

* Previously contact us

8 output signals

- pulse output signal and digital output signal Modbus RTu

A Optional current output signal (4–20 mA) and digital output signal Modbus RTu

X Special order

9 accuracy

1 1%

1,5 1,5%

2 2%

X Special order

10 digital display

- Digital display with basic options

X Special order

11 Pipeline connection

- Flange

FR Flanged reducer type

X Special order

12 calibration, verification

- 5 points factory calibration, pressure test (for technological needs)

Gp Verification (for fiscal metering)

Page 18: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 18 http://www.emis-kip.ru/prod/ed230

eMIs-dIo 230

HIgH accURacY RotoR floWMeteR foR lIIQUIds

eMIs-dIo 230aPPlIcatIonsSuitablefor commercial and industrial metering of liquids with high accuracy up to 0,15%.For liquefied gas, light oil products, oil, oil water, black oil and other viscous fluids measurement applications. used in fuel and energy industry and others.

featURes & adVantages• High accuracy• no straight pipe length requirements• High reliability, noiseless operation• power supply – built-in lithium battery• Digital display

sPecIfIcatIonsprocess fluids ............................................ liquefied gas, liquidsViscosity ...................................................... up to 20000mpa•sprocess temperature limits .................................. -20°C to 250°Cprocess pressure limits ......................................... up to 6,4 Mpapipeline Dn ..................................................... 8 mm to 400 mmAccuracy ....................................................... 0,15 / 0,25 / 0,5%Output signals ..............................pulse / 4-20mA /Modbus RTuExplosion proof ................................................ 1ExdIIC(T2-T6)Xpower supply ............................................................ 3,6V / 24VAmbient temperature ............................................. -40°C to 70°CWater and dust ignition-proof .............................................. Ip65Verification interval ......................................................... 1 yearsConnection type ............................................................flanged

sPecIfIed UnceRtaIntY floW Range

dn, mmfull flow range,

m3/h

0,32-0,8mPa•s 0,8-2 mPa•s2 – 5 mPa•s,

5 – 400 mPa•s400 – 2000

mPa•s2000 – 20 000

mPa•s

Petrol, liquefied gas

Kerosene, waterdiesel oil, crude

oilbitumen

Ultraviscous liquids

0,5 0,25 0,5 0,25 0,5 0,25 0,5 0,25 0,5 0,25008 0,009–0,35 0,06–0,3 0,10–0,3 0,05–0,3 0,07–0,3 0,03–0,3 0,06–0,3 0,03–0,27 0,06–0,27 0,03–0,24 0,06–0,24

015А 0,025–0,9 0,2–0,8 0,27–0,8 0,1–0,8 0,2–0,8 0,08–0,8 0,16–0,8 0,08–0,7 0,16–0,7 0,08–0,6 0,15–0,6

015Б 0,03–1,1 0,25–1 0,33–1 0,2–1 0,25–1 0,1–1 0,2–1 0,1–0,9 0,2–0,9 0,1–0,8 0,2–0,8

015В 0,15–4,5 0,6–3 – 0,4–4 – 0,4–4 – 0,3–2,4 0,3–2,4

025А 0,2–6,5 1,5–6 1,2–6 1,2–6 1,5–6 0,6–6 1,2–6 0,5–5,4 1,2–5,4 0,6–5 1,2–5

025Б 0,3–11 3–8 – 1,5–10 – 1–10 – 1–8 1–6

040 0,8–28 8–20 8–20 2,7–22 5,5–22 2,5–25 4,4–22 2,1–18 4,2–18 1,5–12 3–12

050 1,2–44 9–36 15–36 4,5–36 9–36 4–40 7,2–36 2,8–24 6–24 2,2–18 4,5–18

080 3–100 20–80 32–80 10–80 20–80 9–90 16–80 6,5–56 14–56 5–40 10–40

100 4–110 25–100 40–100 13–100 25–100 12–100 20–100 8,5–72 18–72 6,5–54 14–54

150 8–280 55–225 88–220 31–250 57–225 25–250 44–220 18–150 38–150 12–100 25–100

200 15–440 90–360 150–360 50–400 90–360 40–400 72–360 28–240 53–210 20–160 40–160

250 20–650 135–540 180–540 68–540 135–540 60–600 108–540 42–360 90–360 30–240 60–240

300 30–1100 220–900 300–900 112–900 225–900 100–1000 180–900 70–600 150–600 54–450 113–450

400 90–1700 400–1600 550–1600 200–1600 400–1600 180–1800 320–1600 130–1100 275–1100 90–750 180–750

Those are actual flow ranges for meters made of cast steel and for process temperature up to 150°C; flow ranges for meters made of stainless steel (H1,H2) or for high temperature applications can be found in user manual.

To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please.!Attention!

Page 19: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 19http://www.emis-kip.ru/prod/ed230

eMIs-dIo 230

oRdeRIng InfoRMatIon

tHe eXaMPle of tHe oRdeR:eMIs-dIo 230-Vn-050-sg-st-f-t-1,6-80-0,5-sI-a-gPRotor flowmeter for liquids EMIS-DIO 230 with explosion proof 1ExdllCT6, Dn=50mm, process fluid viscosity up to 0,8mpa•s, process-wetted material is cast steel, with thermal jacket, maximum process pressure up to 1,6Mpa, process temperature limits -40°C to 80°C, with analog current and digital output signals, with filter and connection kit.

1 type of explosion protection- Without explosion protection

Vn Explosion-proof class 1ExdllC(T2-T6)XX Special order2 nominal diameter

008 Dn = 8 мм 150 Dn = 150 мм015 Dn = 15 мм 200 Dn = 200 мм025 Dn = 25 мм 250 Dn = 250 мм040 Dn = 40 мм 300 Dn = 300 мм050 Dn = 50 мм 400 Dn = 400 мм080 Dn = 80 мм X Special order100 Dn = 100 мм

3 flow range- Standard, according to uM

A…B Standard, according to uMX* Specail order

*According to the special order we can produce meters with individual flow ranges. In this case, please tell us your requirements for flow range and put “X” after diameter code (see the example of the order).

4 Process fluid- Liquids with viscosity 0,8mpa to 20000mpa*s (kerosene, water, diesel oil, crude oil, bitumen, ultraviscous liquids)

SG Liquids with viscosity up to 0,8mpa (liquefied gas, petrol)5 Process-Wetted Materials

ST Meter body and rotor made of cast steeln1 Rotor made of stainless steel, meter body made of cast steeln2 Meter body and rotor made of stainless steelX Special order6 Pipeline connectionF Flange

FR* Flanged reducer typeX Special order

*Previously contact us7 thermal jacket - Without thermal jacket

T* Thermal jacket for external heating meter body by steam or oil*EMIS-DIO 230 DN=8 mm is not available with thermal jacket.

8 electronic transmitter type- Electronic transmitter are mounted on primary transducer body

D* Remote type electronic transmitterX Special order

*Maximum cable length 100 m for meters with accuracy 0,15% or for DN40 and more; for other versions maximum cable length is up to 5m.9 Process fluid pressure

1,6 Maximum pressure – 1,6 Mpa2,5 Maximum pressure – 2,5 Mpa4 Maximum pressure – 4,0 Mpa

6,4 Maximum pressure – 6,4 MpaX Special order

10 Process fluid temperature80 process fluid temperature -20°C to 80°C

150 process fluid temperature 80°C to 150°C250 process fluid temperature 150° to 250°C

X Special order11 accuracy 0,5 0,5%

0,25 0,25%0,15 0,15% (please contact our specialists for confirmation)

X Special order12 Indication - Without indication

SI Volume flow digital display 13 output signal- pulse + digital signal RS-485A Optional analog current signal 4-20mAX Special order

14 calibration, verification- Without calibration

Gp Verification (for fiscal metering)

code 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

order eMIs-dIo 230 - Vn - 050 - - - sg - st - f - t - - - 1,6 - 80 - 0,5 - sI - А - gP

Page 20: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 20

oVal geaR MeteR

eMIs-dIo 230l

aPPlIcatIonsEMIS-DIO 230L is used for volume flow measurement of liquids with viscosity up to 2000mpa*s. is simplified version of rotor meter EMIS-DIO 230. The construction of measuring mechanism is easier.This kind of meters is used in petrochemical industry for commercial and process measurement. It is also used in other industries in case it’s suitable for operating conditions.process liquids include petrol, liquefied gas, kerosene, diesel oil, oil, oil water, fuel oil and other liquids used in fuel and energy industries.

featURes and benefIts• Wide range of measurement. • Measurement can be performed for wide viscosity range (up to

2000mpa*s)• Compact and robust• Simple and durable construction of measuring mechanism• Cost-effective compared with rotor meters• Mechanical version of meter is available, doesn’t require power

supply • Easy installation and service

oPtIonal sPecIfIcatIons

ДиАпАзоН рАсхоДА

Item description

EMIS-DIO 230L-CK Connection kit (flanges, gaskets, screw-bolts, nuts, washers)

EMIS-VEKTA VT230L Insert pipes for installation use

EMIS-VEKTA Filter and / or gas separator

EMIS-BRIZ All-purpose power supply unit (for version with output signal)

http://www.emis-kip.ru/prod/ed230L

eMIs-dIo 230l

dnflow ranges with normalized accuracy 0,5%, m3/h

<0,3 mPa*s 0,3-0,8 mPa*s 0,8-2 mPa*s 2-200 mPa*s200-1000

mPa*s1000-2000

mPa*s

10 – 0,2–0,5 0,08–0,5 0,05–0,5 0,03–0,3 0,03–0,2

15 – 0,75–1 0,3–1,5 0,15–1,5 0,1–1,05 0,07–0,75

20 – 1,5–3 0,4–3 0,3–3 0,2–2,1 0,15–1,5

25 4–6 3–6 0,8–6 0,6–6 0,4–4,2 0,3–3

40 9–15 7,5–15 2–15 1,5–15 1,0–10,5 0,7–7,5

50 10–24 8–24 3–24 2,4–24 1,6–16,8 1,2–12

80 40–60 30–60 8–60 6–60 4,2–42 3–30

100 67–100 50–100 13–100 10–100 6–70 5–50

150 127–340 170–340 43–340 34–340 13,3–133 9,5–95

200 227–340 170–340 43–340 34–340 23,8–238 17–170

sPecIfIcatIonsnominal diameter ...................................................... 10 to 200mmprocess viscosity ................................................ up to 2000 mpa*sFlow range ............................................................ 0,03 to 340 m3/hprocess fluid ........................................................................ liquidsprocess fluid temperature ......................................... -40°C to 200°Cprocess pressure ...................................................... up to 6,3 MpaDynamic range................................................................up to 1:10

Accuracy ..................................................................................0,5Output signal*............................................. analog 4-20 mA / pulseExplosion proof* ...........................................................1ExdllBT4Xpower supply* ................................................................... 24 VDCAmbient temperature ..................................................-40°C to 60°CWater and dust ignition proof ...................................................Ip65Verification interval ............................................................... 1 year*For version with output signal

Page 21: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 21http://www.emis-kip.ru/prod/ed230L

eMIs-dIo 230l

oRdeRIng InfoRMatIon

1 2 3 4 5 6 7 8 9 10 11

eMIs-dIo 230 - - - l - 50 - - - - - - - - - - - - - - - gP

1 type of explosion protection

- Without explosion protection

Vn* Explosion-proof class 1ExdllBT4X

X Special order

* For version with output signal

2 Version

L Oval gears version

X Special order

3 nominal diameter

010 Dn =10 mm

015 Dn = 15 mm

020 Dn = 20 mm

025 Dn = 25 mm

040 Dn = 40 mm

050 Dn = 50 mm

080 Dn = 80 mm

100 Dn = 100 mm

150 Dn = 150 mm

200 Dn = 200 mm

X Special order

4 Process fluid

- Liquids with viscosity from 0 to 200 mpa*s

SV* Liquids with viscosity from 200 to 2000 mpa*s

X Special order

* Please contact our specialists first

5 location of indicator

- Integral type ( primary transducer and indicator are mounted on meter body)

X Special order

6 Process pressure

- process pressure – 1,6 Mpa

2,5 process pressure – 2,5 Mpa

4,0 process pressure – 4,0 Mpa

6,3 process pressure – 6,3 Mpa

X Special order

7 Process-Wetted Materials

- Gears and meter body made of cast iron

St Gears made of cast iron, meter body made of cast steel

A1 Gears made of cast iron, meter body made of aluminum

A2 Gears made of aluminum, meter body made of cast iron

X Special order

8 Process fluid temperature

- Standard version, according to uM (see table 1.8)

80 High temperature version, according to uM(see table 1.8)

Vn High temperature version, according to uM (see table 1.8)

X Special order

9 accuracy

0,5 Accuracy class 0,5

X Special order

10 output signal and indication

- Without output signal, mechanical indicator with scale

A* Analog current signal 4-20mA

I* pulse

X* Special order

*Please contact our specialists first

11 calibration, verification

- Factory calibration, pressure test (for technological needs)

Gp Verification (for fiscal metering)

tHe eXaMPle of tHe oRdeR: eMIs-dIo 230-l-50-gP

Page 22: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 22 http://www.emis-kip.ru/prod/em260

eMIs-Mass 260

Mass floWMeteR eMIs-Mass 260aPPlIcatIon used for volume and mass flow measurement, for density, mass and flow measurement of liquids. The information is used for process data communications and accountings in chemical, petrochemical, oil, food, pharmaceutical, other industries and public facilities applications.

featURes & adVantages• no obstructions inside of the process-wetted part• Direct volume flow measurement with high accuracy • Measures density and temperature of the fluid• Modern digital signal processor • no straight pipe length requirements• Automatic temperature data correction• pressure data correction• no moving parts, high reliability • Can be installed and monitored thought RS-485 using “EMIS-Integrator”

software• Can be used with MicroMotion proLink software• Full Russian display menu, all parameters are available to install through the

display

sPecIfIcatIonsnominal diameter ................................................................. 15 to 200mmuncertainty of flow measurement ................................ 0,15%, 0,25%, 0,5%uncertainty of temperature measurement ............................................±1°Cuncertainty of density measurement ....................................... ±0,001g/cm3

Dynamic range.........................................................................up to 1:100Output signal ...................................................... pulse / 4-20 mA / RS-485 process pressure ................................................................. up to 6,4 Mpaprocess fluid temperature .................................................... -50°C to 300°CAmbient temperature ............................................................. -40°C to 55°CExplosion proof .....................................1Exd[ib]llCT6X for electronic module /

1ExibllC(T1-T4)X for sensorWater and dust ignition proof .............................................................. Ip65power supply ............................................................±24 V DC / ~220 V ACVerification interval .......................................................................... 4 year

oPtIonal sPecIfIcatIons

Item description

EMIS-MASS 260-CK Connection kit (flanges, gaskets, stud bolts, screw- nuts, washers)

EMIS-VEKTA VT260 Insert pipes for installation use

EMIS-BRIZ power supply unit

delIVeRY KIt

№ Item amount,

pcs

1 Flowmeter 1

2 Certificate 1

3Verification certificate (if ordered verified meter)

1

4 user manual 1

5 Calibration instructions 1

floW Range

dn, mmflow range t/h depending on accuracy class* Zero point stability,

kg/hfull range 0,15% 0,25% / 0,5%

15 0,03–3 (0,02–2) 0,15–3 (0,2–2) 0,10–3 (0,15–2) 0,225 0,08–8 (0,06–6) 0,4–8 (0,6–6) 0,3–8 (0,4–6) 0,640 0,32–32 (0,36–36) 2–32 (3,6–36) 1,5–32 (2,4–36) 350 0,5–50 (0,5–50) 3,5–50 (5–50) 2,5–50 (3,5–50) 580 1,4–140 6–140 6–140 12

100 2–200 15–200 10–200 20150 5–500 35–500 25–500 50200 10–1000 70–1000 50–1000 100

We are also developing flowmeters with DN 250 and 300 mm, for process pressure up to 25MPa, automatic process pressure correction version and compact version. Please, ask our specialists first.*Flow ranges of compact version are specified in brackets.

Page 23: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 23http://www.emis-kip.ru/prod/em260

eMIs-Mass 260

oRdeRIng InfoRMatIon

tHe eXaMPle of tHe oRdeR:eMIs-Mass 260-ex-050-I-Zh-1,6-100-220-a-0,15-gP(eMIs-Mass 260.cK)Mass flowmeter EMIS-MASS 260 with explosion proof, Dn 50mm, integral type, process-wetted material – stainless steel, maximum process fluid pressure up to 1,6 Mpa, process fluid temperature limits -50°C to 100°C, with analog current, pulse and digital output signals, accuracy class equaled to 0,15% measurement uncertainty, verified, with connection kit.

1 type of explosion protection

- Without explosion protection (standard version)

Ex 1ExibllC(T1-T4)X for sensor, Exd[ib]llCT6X for electronic transmitter

X Special order

2 nominal diameter

015 15 mm 100 100 mm

025 25 mm 150 150 mm

040 40 mm 200 200 mm

050 50 mm X Special order

080 80 mm

3 Meter body version

- Standard, u-tube version

C Compact version

X Special order

4 electronic transmitter type

I Integral type - sensor and electronic transmitter are mounted as one structural element

D Remote type electronic transmitter with cable length of 3m

DXX Remote type electronic transmitter with cable length of XXm (maximum length – 300m)

X Special order

5 Process fluid

Zh Liquid

X Special order

6 Process-Wetted Materials

- Stainless steel (standard version)

X Special order

7 Process fluid pressure

1,6 Maximum process pressure – 1,6 Mpa

2,5 Maximum process pressure – 2,5 Mpa

4,0 Maximum process pressure – 4,0 Mpa

6,4 Maximum process pressure – 6,4 Mpa (for Dn10 – Dn50)

X Special order

8 Process fluid temperature

100 -50°C to 100°C

200 -50°C to 200°, only for remote type transducer version

300 -50°C to 300°, only for remote type transducer version

X Special order

9 Power supply

24 24 VDC

220 220 VAC

X Special order

10 output signal

- pulse output signal + digital signal RS-485 (standard version)

A Optional current output signal 4-20mA

X Special order

11 accuracy

0,15 Accuracy class 0,15

0,25 Accuracy class 0,25

0,5 Accuracy class 0,5

X Special order

12 digital display

- Digital display with basic options

X Special order

13 Pipeline connection

- Flange (standard version)

X Special order

14 calibration, verification

- 5 points factory calibration, pressure test (for technological needs)

Gp Verification (for fiscal metering)

code 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14order eMIs-Mass 260 - ex - 050 - - - I - Zh - - - 1,6 - 100 - 220 - А - 0,15 - - - - - gP

Page 24: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 24 http://www.emis-kip.ru/prod/em270

eMIs-Mag 270

MagnetIc floWMeteR eMIs-Mag 270aPPlIcatIonEMIS-MAG 270 flowmeters are used for volume flow measurement of conductive liquids with flow velocity from 0,1 to 10 m/s, including corrosive, two-phase and polluted liquids (slurries and fluids with particles) with minimal conductivity 5•10-4 cm/m.EM-270flowmeters can be used in automatic process control systems for technological and fiscal metering in power, chemical, paper and other industries. It can be mounted on metal or plastic pipes. EMIS-MAG 270 is also provides reverse flow detection and it is available in two versions for general purposes and for explosion hazardous applications.

featURes & adVantages• Wide range of lining materials and electrodes allow to use EMIS-

MAG 270 for corrosive fluid applications• process pressure up to 32 Mpa• EMIS-MAG 270 flowmetersare able to measure two-phase

liquids and polluted liquids (slurries and liquids with small pieces) because of magnetic measurement principle

• Accuracy of the flow measurement is not related with fluid viscosity and density

• Wide range of pipeline Dn with maximum Dn 3000mm allows to use this flowmeter for high-flow applications

• Cost-effective (built-in indicator allows to use EMIS-MAG 270 without optional indicating devices)

• Variable installation (can be mounted on horizontal or vertical pipeline sections)

• Verification interval at the market leaders level• no moving parts and parts inserted into pipe• Low pressure loss

floW Range

dn, mmQmin, m3/h

Q1, m3/h

Q2, m3/h

Qmax, m3/h

15 0,06 0,19 0,64 6,4020 0,11 0,34 1,13 11,3025 0,18 0,53 1,77 17,7032 0,30 0,87 2,89 28,9040 0,45 1,34 4,50 45,0050 0,71 2,13 7,10 71,0065 1,20 3,57 11,90 11980 1,80 5,43 18,10 181

100 2,80 8,49 28,30 283125 4,40 13,30 44,20 442150 6,40 19,10 63,60 636200 11,30 33,90 113 1130250 17,70 53,10 177 1770300 25,50 76,20 254 2540350 34,60 104 346 3460400 45,00 136 452 4520450 57,00 172 572 5720500 70,50 212 707 7070600 100 306 1020 10 200700 140 416 1385 13 850800 180 543 1810 18 100900 230 687 2290 22 900

1000 280 849 2830 28 3001200 407 1221 4070 40 7001400 554 1662 5540 55 4001600 724 2172 7240 72 4001800 916 2748 9160 91 6002000 1130 3393 11 310 113 1002200 1368 4100 13 680 136 800

oPtIonal sPecIfIcatIonsItem description

EMIS-MAG 270-CKConnection kit (flanges, gaskets, screw- bolts, screw- nuts, washers)

EMIS-MAG 270 VT Insert pipes

EMIS-MAG 270 ZK Ground ring

EMIS-BRIZ power supply unit

EMIS -SYSTEMA 750 RS-485 converter

HART ModemHART protocol data communication device

Pulse, frequency and digital signal intrinsic error limit is:±0,5% for Qmax≥Q>Q2;±1,0% for Q2≥Q>Q1;±5% for Q1≥Q>Qmin.

sPecIfIcatIonsnominal Diameter .............................................. 15 to 3000mmuncertainty ....................................................................... ±0,5Dynamic range................................................................ 1:100process pressure ................................................. up to 32 Mpaprocess fluid temperature .................................... -40°C to 180°CAmbient temperature ............................................. -40°C to 75°COutput signal ..............................analog current signal 4-20 mA /

frequency or pulse signal / ModBus /HARTExplosion proof .................1Exd[ib]llCT6X for electronic module /

1ExibllC(T1-T4)X for sensorWater and dust ignition proof .............................................. Ip65power supply ............................................±24 V DC / ~220 V ACVerification interval ...........................................................4 year

Page 25: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 25http://www.emis-kip.ru/prod/em270

eMIs-Mag 270

oRdeRIng InfoRMatIon

1 type of explosion protection

- Without explosion protection

Ex1ExiallC(T3-T4)X for sensor, Exd[ib]llCT6X (intrinsically-safe circuit)for primary transducer1Exd[ia]llCT4X (intrinsically-safe circuit, explosion-proof enclosure) for electronic transmitter

X Special order

2 nominal diameter

015 Dn = 15 600 Dn = 600

020 Dn = 20 700 Dn = 700

025 Dn = 25 800 Dn = 800

032 Dn = 32 900 Dn = 900

040 Dn = 40 1000 Dn = 1000

050 Dn = 50 1200 Dn = 1200

065 Dn = 65 1400 Dn = 1400

080 Dn = 80 1600 Dn = 1600

100 Dn = 100 1800 Dn = 1800

125 Dn = 125 2000 Dn = 2000

150 Dn = 150 2200 Дy = 2200

200 Dn = 200 2400* Dn = 2400

250 Dn = 250 2600* Dn = 2600

300 Dn = 300 2800* Dn = 2800

350 Dn = 350 3000* Dn = 3000

400 Dn = 400 Х Special order

450 Dn = 450 * Please contact our specialists for confirmation first.

500 Dn = 500

3 flow range

- Standard, according to the Table 1

X Special order

4 transducer materials

- Cast steel

n1* Stainless steel(SS304)

n2* Stainless steel (SS316L)

X Special order

* Please contact our specialists for confirmation first.

5 lining materials

pTF polytetrafluoroethylene (pTFE-4)

CR Chloroprene rubber (technical rubber)

FEp Fluorinated ethylene propylene

pp polypropylene

pFA* perfluoroalkoxy

pK* polyurethane rubber (technical rubber)

X Special order

* Please contact our specialists for confirmation first.

6 electrode Materials

- Stainless steel (SS316L)

HC Hastelloy C

HB* Hastelloy B

V Tungsten carbide

TI Titanium

TA Tantalum

pT* platinum-iridium composition

X Special order

* Please contact our specialists for confirmation first.

code 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15order eMIs-Mag 270 ex - 080 - - - - - PP - tI - - - - - 6,4 - - - - - - - 24 - М - gP

Page 26: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 26 http://www.emis-kip.ru/prod/em270

7 Pipeline connection

- Flange

X Special order

8 electronic transmitter type

- Integral type - ( primary transducer and transmitter are mounted as one structural element)

D* Remote type electronic transmitter with cable length of 3 m

DXX* Remote type electronic transmitter with cable length of XXm (maximum length – 300 m)

*Explosion proof only for primary transducer.

9 Process pressure

0,6 0,6 Mpa

1,0 1,0 Mpa

1,6 1,6 Mpa

2,5 2,5 Mpa

4,0 4,0 Mpa

6,4 6,4 Mpa

10 10 Mpa

15 15 Mpa

25 25Mpa

32 32 Mpa

X Special order

10 Process temperature

- Standard, according to Table 5

X Special order

11 accuracy

0,5 Standard, according to Table 2

X Special order

12 digital display

- Digital display with basic options

X Special order

13 Power supply

24 24 V DC

220* 220 V AC

X Special order

*only for versions without explosion proof.

14 output signal

- pulse output signal + analog signal 4–20 mA

M Optional digital interface ModBus-RTu

H Optional digital interface HART

X Special order

15 calibration, verification

- Factory calibration, pressure test (for technological needs)

Gp Verification (for fiscal metering)

eMIs-Mag 270

tHe eXaMPle of tHe oRdeR:eMIs-Mag 270-ex-080-PP-tI-6,4-24-M-gP(eMIs-Mass 260.cK)EMIS-MAG 270 flowmeter with explosion proof 0ExiallC(T3-T4)X for primary transducer and 1Exd[ia]llCT4X for electronic transmitter, Dn 80mm,standard flow range, primary transducer body material – cast steel, lining material – polypropylene, electrode material – titanium, flange pipeline connection type, integral type transmitter, process fluid pressure 6,4 Mpa, standard process fluid temperature limits, standard measurement accuracy, digital display with basic options, power supply 24V DC, with pulse and current 4-20 mA output signals and digital interface ModBus-RTu, verified.

Page 27: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 27

floW sWItcH foR lIQUIds eMIs-PotoK

featURes & adVantages• Durable and reliable in service • Suitable for direct and reverse flow • Resistant to high process fluid temperature• Suitable for High north applications• High process pressure limit

sPecIfIcatIonsnominal pipe sizes .........................................................25-100mmExcess pressure ........................................................... up to 5Mpaprocess fluid temperature ...................................... -30°C to +150°C*Explosion proof ...................................................... 1ExdllB(T4-T6)XOutput signal ............................................................ SpDT contact *Process fluid temperature for Vn version: -30°C…+100°C.

oPtIonal sPecIfIcatIons

http://www.emis-kip.ru/prod/ep_236

eMIs-PotoK 236

aPPlIcatIonFlow switches are used to protect pumps, engines and other devices from overheating, caused by low flow or it absence. It is usually used in automatic process control and management systems in power, chemical, petrochemical, food, paper and other industries.Flow switches are dedicated to be mounted on pipeline.Two versions: for general purpose and for explosion hazardous area.

Item description

Connection cables To connect flow switches to control and measuring instruments

featURes & adVantages• no moving part• Body material – aluminum alloy, flow sensor – stainless steel

SS304• Durable and reliable in service • Suitable for direct and reverse flow • Suitable for High north applications• High process pressure limit

sPecIfIcatIonsnominal pipe sizes ................................................... 25-300mmprocess fluid pressure ..............................................up to 5Mpaprocess fluid temperature .................................... -50°C to +65°CFlow velocity range:For water .................................................................. 0,02-5m/sFor crude oil ............................................................. 0,03-3m/sFor gas ...................................................................... 0, 3-5m/sExplosion proof ........................................................1ExdllBT6XOutput signal ...................................................... SpDT contact

eMIs-PotoK 285 – tHeRMal dIsPeRsIon floW sWItcH

eMIs-PotoK 236 – Paddle tYPe floW sWItcH

Page 28: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 28 http://www.emis-kip.ru/prod/ep_236

eMIs-PotoK 236

oRdeRIng InfoRMatIon foR eMIs-PotoK 236

1 2 3 4 5 6

eMIs-PotoK 236 - Vn - - - 5 - х - - - -

1 explosion protection

- Without explosion protection

Vn Explosion proof 1ExdllB(T4-T6)X

2 nominal pipe sizes

- up to 100mm

X Special order

3 Process fluid pressure

2,5 2,5Mpa

5 5Mpa

X Special order

4 Process fluid temperature

-* -30°C…+150°C

X Special order

5 connection type

- R1 GOST 6211-81

X Special order

6 output signal

- SpDT contact

X Special order

tHe eXaMPle of tHe oRdeR: eP 236-Vn-5-X

*- process fluid temperature for Vn version: -30°C…+100°C.Flow switches for pipe sizes more than 100mm and other process fluid parameters are available by special order.Standard flow switches are dedicated for horizontal pipelines.

oRdeRIng InfoRMatIon foR eMIs-PotoK 2851 2 3 4 5

eMIs-PotoK 285 - Vn - 5 - - - х - -

1 explosion protection

- Without explosion protection

Vn Explosion proof 1ExdllBT6X

2 nominal pipe sizes

- up to 300mm

X Special order

3 Process fluid pressure

2,5 2,5Mpa

5 5Mpa

X Special order

4 Process fluid temperature

- -50°C…+65°C

X Special order

5 connection type

- K1/2 GOST 6111-52

X Special order

6 output signal

- SpDT contact

X Special order

tHe eXaMPle of tHe oRdeR: eP 285-Vn-5-X

Page 29: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 29

eMIs deeP-Well ReseaRcH coMPleX

http://www.emis-kip.ru/prod/gik

eMIs deeP-Well ReseaRcH coMPleX

To prevent wrong choice of equipment, EMIS questionnaire for deep-well research complex should be attached to your order, please.!Attention!

aPPlIcatIonsEMIS deep-well research complex is based on vortex flowmeter EMIS-VIHR 200-SKV and ultrasonic flowmeter EMIS-uLTRA 292-SKV. It provides on-line parameters control and optimization of well operation process based on received data.EMIS deep-well research complex is dedicated for permanent liquid parameters control of certain developing wells equipped with independent parallel operation system.

featURes & adVantages• EMIS-VIHR 200-SKV and EMIS-ultra 292-SKV flowmeter provides

permanent control of well operating parameters• Wide flow rang 1:40 and high measurement accuracy• provides data communication to high level of Control System

through radio link or GpRS; access to measurement data store is available anytime and anywhere

• Vortex principle and digital signal processing provide high accuracy 1,5%, warranted with certificate of conformity for measure instruments

• up to 3 flowmeters can be set on one logging cable• Smart signal processing, background noises reduction• Metrological characteristics accuracy control

MeasURIng PaRaMeteRs• Day well rate• Current flow rate• pressure• Temperature

Delivery kit includes component kit for easy installation and reliable service of the whole complex:• Cable outlet sealing device• Cable protectors for installation and protection use• Armored cable with corrosive protection jacket

base case

Item application

Bore-hole vortex flowmeter EMIS-VIHR 200-SKV or ultrasonic flowmeter EMIS-ultra 292-SKV

Day well rate measurement and current flow rate measurement

Temperature sensorTubing outside temperature measurement

pressure sensorOutside and inside pressure measurement

Onshore interface module

Changed parameters data processing, storage and display. Data communication to high level of Control System

sPecIfIcatIonsWell type .............................. oil producing well / water-injection wellDynamic range................................................................ up to 1:40Flow range ................................. 1to 30 m3/day / 4,7 to 190 m3/day /

12,5 to 500 m3/dayFlow measurement accuracy ...........................................up to ±5%Water cut ....................................................................... 0 to 100%pressure measurement accuracy .......................................... 0,16%process fluid pressure ................................................. up to 50Mpapressure change resolution ..............................................0,001Mpaprocess fluid temperature ....................................... -20°C to +105°CTemperature measurement accuracy ....................................... 0,5%Temperature change resolution ............................................ 0,0033

Production tubing

cable output

armored communication cable

eMIs deeP-Well ReseaRcH coMPleX

Packer (sleeve packer)

special structure sucker rod pump

cable protectors with cable coupling boxes

Producing formation

Producing formation

controller (interface block)

Page 30: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 30 http://www.emis-kip.ru/prod/emis-esko

eMIs-esKo 2210

eneRgY caRRIeR MeteRIng sKId

eMIs-esKo 2210

base case

oPtIonal sPecIfIcatIons

Item code

Measuring devices*

Vortex transmitter EMIS-VIHR 200 (205)

pressure transducer AIR-10Н (AIR-10L, AIR-10S, AIR-20)

Resistance temperature sensor TpT-1-3computing device

Metering controller TEKOn 19-05MPower supply unit

power supply unit EMIS-BRIZ 90-4-24-100-DIn

connection kit

Flowmeter CK EV-200.CK

Valve block BKn-1-08

Weldolet for pressure sensor mounting EMIS-VEKTA 1130

pressure reducing valve EMIS-VEKTA 1120

protection sleeve EMIS-VEKTA 1300

Weldolet for temperature sensor mounting EMIS-VEKTA

Item application conditions

code

connection kit

Meter runspipepipeline Dn and flowmeter Dn are not match together

uI-200

Flow straightener Straight pipe length requirements can’t be accomplished

EMIS-VEKTA 1200

Installation closet

KIp installation closetFor controllers, power supply units and other devices

InWBV 40.30.20

Vandal-proof closet To close metering skid and functional inside of the closet.

pipe closet

communication devices

Controller K-104 Ethernet local area network K-104

Controller GpRS/GSM Wireless communication K-105

protocol interface unit uSp 78

RS-485 interface to connect external system

uSp 78

Intrinsic safety barriers

Bypass diode intrinsic safety barrier BIS-A-Ex (100 series)

For Exd hazardous area application BIS-A-108-Ex

BIS-A-Ex (100 series) For Exia hazardous area application

BIS-A-111-Ex

Intrinsic safety barrier with galvanic isolation BIS-A-Ex (300 series)

BIS-A-301-Ex

aPPlIcatIonsEMIS-ESKO 2210 metering skid is dedicated to measure flow, pressure, temperature, mass and the amount of media inside of the pipeline. It is used for commercial and technological metering of saturated and overheated steam, associated petroleum gas, natural gas, mixed gas, liquids and water solutions and also in water injection systems.

featURes & adVantages• Can be used in water injection systems• Measures associated petroleum gas• Serviceability• High reliable construction• Verification interval up to 4 years• Stable metrological characteristics• Flexibility ( suitable for different fluids)• Remote data communications ( including wireless

communication)

sPecIfIcatIonsnominal diameter ...............................................15 to 2000 mmprocess fluids ..................................................steam/gas/liquidprocess fluid temperature .................................. -40°C to +460°Cprocess fluid pressure ............................................ up to 25MpaAccuracy ( for gas under normal conditions ......................... 1,5%Accuracy (for steam under normal conditions ...................... 3,0%Communication interface....... RS-232/485; GSM/GpRS; Ethernetpower supply .........................................................(220+22) V AC

electricity network with frequency (50±1)HzAmbient temperature for transmitters .....................40°C to +70°CVerification interval ......................................................... 4 years

-33

MeasURIng PaRaMeteRsVolume flow, mass flow, quantity of heat energy, process fluid temperature, process fluid pressure.

* - metering skid can be equipped with other measuring devices with the same specifications.

Page 31: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 31http://www.emis-kip.ru/prod/emis-esko

eMIs-esKo 2210

oRdeRIng InfoRMatIon

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

eMIs-esKo 2210 1 - Zh - 1,5 - 1.60 - 100 - 150 / 200 - Ех - st - Msh - - - gP - I - - - - - V

0 Product name

EMIS-ESKO 2210 EMIS-ESKO 2210 metering skid

1 Metering point number

1 One point

2 Two points

3 Three points

4 Four points

X Special order

2 Process fluid

Zh Liquid

G Gas

p Steam (saturated/overheated)

X Other

3 accuracy

1,5 1,5%

2,5 2,5%

3,5 3,5%

5,0 5,0%

X Special order

4 Maximum process fluid pressure (absolute)

0,04 0,04 Mpa 0,40 0,40 Mpa 4,00 4,00 Mpa

0,06 0,06 Mpa 0,60 0,60 Mpa 6,30 6,30 Mpa

0,10 0,10 Mpa 1,00 1,00 Mpa 10,00 10 Mpa

0,16 0,16 Mpa 1,60 1,60 Mpa Х Special order

0,25 0,25 Mpa 2,50 2,50 Mpa

5 Process fluid temperature

100 -40 to +100 °С 460 -40 to +460 °С

250 -40 to +250 °С Х Special order

320 -40 to +320 °С

6 Pipeline connection size

015 15 mm 080 80 mm 300 300 mm

025 25 mm 100 100 mm 350 350 mm

032 32 mm 125 125 mm 400 400 mm

040 40 mm 150 150 mm …. …

050 50 mm 200 200 mm 2000 2000 mm

065 65 mm 250 250 mm Х Special order

7 flowmeter dn

015 15 mm 080 80 mm 300 300 mm

025 25 mm 100 100 mm 350 350 mm (for EV 205)

032 32 mm 125 125 mm 400 400 mm (for EV 205)

040 40 mm 150 150 mm …. … ( for EV 205)

050 50 mm 200 200 mm 2000 2000 mm (for EV 205)

065 65 mm 250 250 mm Х Special order

Page 32: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 32

8 explosion protection

- General purpose industrial version

Exd Explosion proof enclosure for transmitters

Exib Intrinsically safe circuit for transmitters

X Special order

9 Pipeline material

n Stainless steel

St Cast steel

X Special order

10 closet

MSh Closet for controllers and power supply units

ShT Closet for metering skid and functional devices

- Without closet

X Special order

11 communication interface

- RS-232 (uSB) / CAn-BuS

GpRS / GSM GpRS / GSM

RS-485 RS-485

E Ethernet

X Special order

12 testing, calibration

- Factory calibration

Gp Verification

13 Required software

- Software for local data acquisition (Teleport software)

I “ISKRa” software for remote data acquisition

S Data integration to high level of SCADA

14 connecting cable for metering controller

D5/5 Cable 5x0,5 mm2, 5m (standard, marked)

- not required

15 Meter runs

10/5 10Dn upstream, 5Dn downstream (standard version)

- Without meter runs

X Special order

16 Meter runs welding joints control

V Visual and measuring control – 100%

H Chemical control – 100%, visual and measuring control – 100%

uZ1 ultrasonic control – 100% (according to VSn 012-88), visual and measuring control – 100%

http://www.emis-kip.ru/prod/emis-esko

eMIs-esKo 2210

Page 33: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 33http://www.emis-kip.ru/prod/emis-esko

eMIs-esKo 2210

MeteRIng sKId WItH self-contaIned PoWeR sUPPlY UnIt eMIs-esKo 2210-aIP

aPPlIcatIonsMetering skid with self-contained power supply unit is dedicated for remote control of process parameters, to measure flow, pressure, temperature, mass and quantity of fluid inside of the pipeline.It is used for commercial and technological metering of saturated and overheated steam, associated petroleum gas, mixed gas, liquids and water solutions in areas situated far from warranted power supply.Self-contained power supply unit includes thermoelectric generator or solar battery with accumulator box.

featURes & adVantages• Can be used without external electricity source• Vandal-proof closet is available • Easy mounting, reliable construction• Verification interval 4 years• High durability of self-contained power supply unit• Suitable for High north and for hot weather applications• Remote data communications

To prevent wrong choice of equipment, EMIS questionnaire for EMIS-ESKO 2210 metering skid should be attached to your order, please.!Attention!

sPecIfIcatIonsnominal diameter .................................................50 to 300 mmprocess fluids ..................................................steam/gas/liquidprocess fluid temperature .................................. -40°C to +460°Cprocess fluid pressure .......................................... up to 6,3 MpaCommunication interface............................ RS-232; GSM/GpRSAmbient temperature:For transmitters .................................................. -40°C to +70°CFor controllers .................................................... -10°C to +50°CVerification interval ...................................................1 to 4 yearsSelf-contained power supply unit resource:TEG .............................................................................. 8 yearsSolar panel .................................................................. 15 years

base case

№ Item Quantity note

1 EMIS-ESKO 2210 metering skid 1 piece Version according to the order

2 Self-contained power supply unit 1 piece Version according to the order

3 Closet 1 piece

4 Calibration procedure manual 1 copy

5 user manual 1 copy

6 Certificate 1 copy

Page 34: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 34 http://www.emis-kip.ru/prod/ev1200

eMIs-VeKta 1200

floW condItIoneRs / stRaIgHteneRs eMIs-VeKta 1200

aPPlIcatIonDedicated to reduce straight pipe length requirements. It is usually used with vortex flowmeters, ultrasonic flowmeters, differential pressure flowmeters and other types of flowmeters. Suitable for liquids, gases and stem pipelines. According to “Zanker” type flow conditioner GOST p 8.586.1.

featURes & adVantages• Compact design • High-effective for flow stabilisation• Suitable for different types of flowmeters• Easy installation• Long-term service• Standard flanges (facing type 3, GOST 12815-80)

sPecIfIcatIonsprocess pressure .......................................... liquid /gas / steamnominal diameter ........................................ 15 mm to 1200 mmMaterial ................................... cast steel / stainless steel / other

oRdeRIng InfoRMatIonThe example of the order:

1 Pipeline dn015 Dn = 15 mm025 Dn = 25 mm032 Dn = 32 mm040 Dn = 40 mm050 Dn = 50 mm065 Dn = 65 mm080 Dn = 080 mm100 Dn = 100 mm 125 Dn = 125 mm150 Dn = 150 mm200 Dn = 200 mm250 Dn = 250 mm300 Dn = 300 mm350 Dn = 350 mm400 Dn = 400 mm500 Dn = 500 mm600 Dn = 600 mm700 Dn = 700 mm800 Dn = 800 mm900 Dn = 900 mm

1000 Dn = 1000 mm1200 Dn = 1200 mm

XXX

To make hole sizes of flow conditioner in strict accordance with GOST R 8.586.1, please specify actual inner diameter of pipeline XXX in mm

2 Material St Cast steeln Stainless steelX Special order

oPtIonal sPecIfIcatIonsItem description

EMIS-VEKTA 1200.CK-Dn-St-p Connection kit (cast steel flanges, gaskets, stud bolts or bolts, screw- nuts, washers)

EMIS-VEKTA 1200.CK-Dn-n-pConnection kit (stainless steel flanges, gaskets, stud bolts or screw- bolts, screw- nuts, washers)

Here P - is maximum pressure in MPa (1,6; 2,5; 4,0; 6,3; 10; 16; 20), DN – is Nominal diameter , X – is special order.

0 1 2eMIs-VeKta 1200 078 - n

Page 35: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 35

oPtIonal sPecIfIcatIonsItem description

EMIS-VEKTA 1210.CK Connection kit (flange, gaskets, screw-bolts, screw- nuts, washers)

EMIS-VEKTA 1210.VT Insert pipes for installation use

EMIS-VEKTA 1210.SFE Filter cartridge

delIVeRY KIt№ Item amount, pcs

1 Filter 1

2 user manual and certificate 1

3 passport 1

4 package 1

Note: * - for DN≥50mm.

eMIs-VeKta 1210

lIQUId fIlteRs eMIs-VeKta 1210aPPlIcatIonused to filter out particles from fluid. Are mounted upstream of flowmeter or metering system to protect it from breakdown, to improve metrological characteristics and service life. used in oil filling and transfer stations (crude oil, oil products and other liquids).

sPecIfIcatIonsnominal Diameter ...................................................................... 15 mm to 600 mmMaximum process pressure........................................................................ 6,4 MpaRetention rate ................................................................................. 38 to 8000 µm

(standard: 1700, 830, 380 µm, depending on process fluid viscosity) Connection type .......................................................................................... flange

VeRsIons

Item note dn, mm

Maximum process

pressure, MPa

Process temperature, °c ambient temperature, °cMaterial Material

st n1, n2, stn st n1, n2, stn

-(standard version)

«Y»-type 15 – 40 4 -30 to +250

-20 to +80 -40 to +80With round attachments

cower

50 – 300 6,4-20 to +250 -40 to +250

400 – 600 2,5

B With quick-opening clump

cover50 – 300 6,4 -20 to 150

http://www.emis-kip.ru/prod/ev1210

floW Ranges foR eMIs-VeKta 1210 (m3/h)

dn, mmPetrol, liquefied gas, diesel

oil, crude oil, residual oilbitumen liquid viscosity

≥2000 mPa•s0,32 – 400 mPa•s 400 – 2000 mPa•s

015 0–4,5 0–2,6 0–2,4

025 0–11 0,5–8,8 0–6,6

040 0–28 0–19,8 0–13,2

050 0–44 0–26,4 0–19,8

080 0–110 0–66 0–55

100 0–165 0–100 0–77

150 0–280 0–165 0–110

200 0–480 0–264 0–176

250 0–700 0–396 0–264

300 0–1100 0–660 0–495

400 0–1760 0–1210 0–825

Page 36: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 36

oRdeRIng InfoRMatIon

1 2 3 4 5 6 7 8 9 10

eMIs-VeKta 1210 - b - 200 - st - - - Т - 4.0 - - - 830 - -

2 Version

- Standard version

B Quick opening cover

3 nominal diameter

015 Dn = 15 mm 300 Dn = 300 mm

025 Dn = 25 mm 400 Dn = 400 mm

040 Dn = 40 mm 500 Dn = 500 mm

050 Dn = 50 mm 600 Dn = 600 mm

080 Dn = 80 mm Х Special order

100 Dn = 100 mm

150 Dn = 150 mm

200 Dn = 200 mm

250 Dn = 250 mm

4 Housing materials

St Cast steel Ст20

Stn* Low-alloy steel 17Г1С

n1 Stainless steel 08Х18Н10 (SS304 analog)

n2 Stainless steel 03Х17Н14М2 (SS316 analog)

X Special order

* Only for DN≥50mm.

5 filter cartridge materials

- Stainless steel 08Х18Н10 (SS304 analog)

X Special order

6 thermal jacket

- Without thermal jacket

T Thermal jacket for filter housing

7 Process pressure

1,6 1,6 Mpa

2,5 2,5 Mpa

4,0 4,0 Mpa

6,4 6,4 Mpa

X Special order

8 Process temperature

- According to Table 1

X Special order

9 Retention rate

1700 For liquids with viscosity from 400 mpa*s to 3000 mpa*s

830 For liquids with viscosity from 2 mpa*s to 400 mpa*s

380 For liquids with viscosity from 0,32 mpa*s to 2 mpa*s

XXXX Requiring mesh size(µm)

10 differential pressure gauge connection

- no

D Thread holes for differential pressure gauges (standard M20x1,5)

X Special order

eMIs-VeKta 1210

http://www.emis-kip.ru/prod/ev1210

To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please.!Attention!

Page 37: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 37

http://www.emis-kip.ru/prod/ev1210

oPtIonal sPecIfIcatIonsItem description

EMIS-VEKTA 1215.CK Connection kit (flange, gaskets, screw-bolts, screw- nuts, washers)

EMIS-VEKTA 1215.VT Insert pipes for installation use

EMIS-VEKTA 1215.SFE Filter cartridge

delIVeRY KIt№ Item amount, pcs1 Filter 12 user manual and certificate 13 passport 14 package 1

Note: * - for DN≥50mm.

eMIs-VeKta 1215

VeRsIons

Item note dn, mmMaximum process

pressure, MPa

Process temperature,

°c

ambient temperature, °c

Material st, n1, n2, stn

Material st, n1, n2, stn

-(standard version)

“Y”-type2,5 -20 to +80 -20 to +70With round attachments cower 50 – 300

B With quick-opening clump cover 50 – 300

gas fIlteRs eMIs-VeKta 1215aPPlIcatIonused to filter out particles from fluid. Are mounted upstream of pressure regulator, meters or other equipment to protect it from breakdown, to improve metrological characteristics and service life. Dedicated for natural gas and other non-corrosive gases filtration in gas supply systems according to GOST 5542-87.

sPecIfIcatIonsnominal Diameter ................................................................ 15 mm to 300 mmMaximum process pressure .................................................................. 2,5 MpaRetention rate ............................................................................. 38 to 8000 µm

(standard: 180, 150µm, depending on process fluid parameters) Connection type ..................................................................................... flange

oRdeRIng InfoRMatIon1 2 3 4 5 6 7 8 9 10

eMIs-VeKta 1215 - - - 15 - n1 - - - - - 1.6 - - - 180 - -

2 Version- Standard versionB Quick opening cover3 nominal diameter

015 Dn = 15 mm 150 Dn = 150 mm025 Dn = 25 mm 200 Dn = 200 mm040 Dn = 40 mm 250 Dn = 250 mm050 Dn = 50 mm 300 Dn = 300 mm080 Dn = 80 mm Х Special order100 Dn = 100 mm

4 Housing materialsSt Cast steel Ст20

Stn* Low-alloy steel 17Г1Сn1 Stainless steel 08Х18Н10 (SS304 analog)n2 Stainless steel 03Х17Н14М2 (SS316 analog)X Special order

* Only for DN≥50mm.5 filter cartridge materials- Stainless steel 08Х18Н10 (SS304 analog)X Special order6 thermal jacket - Without thermal jacketT Thermal jacket for filter housing7 Process pressure

1,6 1,6 Mpa2,5 2,5 MpaX Special order8 Process temperature- According to Table 1X Special order9 Retention rate

180 For liquids with viscosity 180 mpa*s 150 For liquids with viscosity 150 mpa*s

XXXX Requiring mesh size(µm)10 differential pressure gauge connection - noD Thread holes for differential pressure gauges (standard M20x1,5)X Special order

http://www.emis-kip.ru/prod/ev1210

To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please.!Attention!

Page 38: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 38

eMIs-VeKta 1212

VeRsIons

oPtIonal sPecIfIcatIonsItem description

EMIS-VEKTA 1212.CK Connection kit (flange, gaskets, screw-bolts, screw- nuts, washers)

EMIS-VEKTA 1212.VT Insert pipes for installation use

EMIS-VEKTA 1212.SFE Filter cartridge

delIVeRY KIt

№ Item amount, pcs

1 Filter 1

2 user manual and certificate 1

3 passport 1

4 package 1

Item note dn, mm

Maximum process

pressure, MPa

Process temperature, °c ambient temperature, °cMaterial Material

st n1, stn st n1, stn

- (standard version)

With round attachments cower

40 – 300 6,4-20 to +250 -40 to +250

-20 to +80 -40 to +80350 – 800 2,5

BWith quick-opening

clump cover40 – 300 6,4 -20 to +150

fIlteR-sePaRatoR eMIs-VeKta 1212aPPlIcatIonused to filter out steam, gas and particles from liquid. Are mounted upstream of flowmeter or metering system to protect it from breakdown, to improve metrological characteristics and service life. used in oil filling and transfer stations (crude oil, oil products and other liquids).

sPecIfIcatIonsnominal diameter ................................................................. 40 mm to 800 mmMaximum process pressure .................................................................. 6,4 MpaRetention rate ............................................................................. 38 to 8000 µm

(standard: 1700, 830, 380 µm, depending on process fluid viscosity) Connection type ..................................................................................... flange

http://www.emis-kip.ru/prod/ev1210

floW Ranges foR eMIs-VeKta 1212 (m3/h) WItH dIffeRent lIQUId VIscosItY

dn, mmPetrol, liquefied gas, diesel

oil, crude oil, residual oilbitumen liquid viscosity

≥2000 mPa•s0,32 – 400 mPa•s 400 – 2000 mPa•s

040 0–28 0–19,8 0–13,2

050 0–44 0–26,4 0–19,8

080 0–110 0–66 0–55

100 0–165 0–100 0–77

150 0–280 0–165 0–110

200 0–480 0–264 0–176

250 0–700 0–396 0–264

300 0–1100 0–660 0–495

400 0–1760 0–1210 0–825

300 0–1100 0–660 0–495

400 0–1760 0–1210 0–825

Page 39: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 39

oRdeRIng InfoRMatIon

1 2 3 4 5 6 7 8 9 10

eMIs-VeKta 1212 - - - 800 - st - - - - - 2.5 - - - 830 - -

2 Version

- Standard version

B Quick opening cover

3 nominal diameter

040 Dn = 40 mm 300 Dn = 300 mm

050 Dn = 50 mm 350 Dn = 350 mm

080 Dn = 80 mm 400 Dn = 400 mm

100 Dn = 100 mm 500 Dn = 500 mm

150 Dn = 150 mm 600 Dn = 600 mm

200 Dn = 200 mm 700 Dn = 700 mm

250 Dn = 250 mm 800 Dn = 800 mm

Х Special order

4 Housing materials

St Cast steel Ст20

Stn* Low-alloy steel 17Г1С

n1 Stainless steel 08Х18Н10 (SS304 analog)

n2 Stainless steel 03Х17Н14М2 (SS316 analog)

X Special order

* Only for DN≥50mm.

5 filter cartridge materials

- Stainless steel 08Х18Н10 (SS304 analog)

X Special order

6 thermal jacket

- Without thermal jacket

T Thermal jacket for filter housing

7 Process pressure

1,6 1,6 Mpa

2,5 2,5 Mpa

4,0 4,0 Mpa

6,4 6,4 Mpa

X Special order

8 Process temperature

- According to Table 1

X Special order

9 Retention rate

1700 For liquids with viscosity from 400 mpa*s to 3000 mpa*s

830 For liquids with viscosity from 2 mpa*s to 400 mpa*s

380 For liquids with viscosity from 0,32 mpa*s to 2 mpa*s

XXXX Requiring mesh size (µm)

10 differential pressure gauge connection

- no

D Thread holes for differential pressure gauges (standard M20x1,5)

X Special order

eMIs-VeKta 1212

http://www.emis-kip.ru/prod/ev1210

To prevent wrong choice of equipment, EMIS questionnaire should be attached to your order, please.!Attention!

Page 40: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 40

oRdeRIng InfoRMatIon

0 1 2 3 4 5 6

InseRt PIPes eMIs-VeKta Vt Vt200 - 080 - st - s - 1,6 - V

1 flowmeter type

VT200 EMIS-VIHR 200

VT215 EMIS-META 215

VT220 EMIS-pLAST 220

VT220R EMIS-pLAST 220R

VT230 EMIS-DIO 230

VT240 EMIS-VEnTuRY 240

VT260 EMIS-MASS 260

VT270 EMIS-MAG 270

X Special order

2 nominal diameter

008 Dn=08 mm

… Dn=… mm

400 Dn=400 mm

X Special order

3 Material

St Cast steel

n Stainless steel

09G2S Steel 09G2S

X Special order

4 Pipeline connection

S Sandwich

F Flange

X Special order

5 Process pressure

1,6 up to 1,6 Mpa 6,3 up to 6,3 Mpa 25,0 up to 25,0 Mpa

2,5 up to 2,5 Mpa 10,0 up to 10,0 Mpa 42,0 up to 42,0 Mpa

4,0 up to 4,0 Mpa 16,0 up to 16,0 Mpa X Special order

6 Welding joins control

V Visual and measuring control – 100%

H Chemical control – 100%, visual and measuring control – 100%

uZ ultrasonic control (according to ВСН 012-88), visual and measuring control – 100%

InseRt PIPes eMIs-VeKta Vt

aPPlIcatIon Dedicated to be mounted on pipeline instead of relevant flowmeter. It is used during flowmeter repairs, verification or during welding counter flanges to the pipeline.

eMIs-VeKta Vt

http://www.emis-kip.ru/prod/vt

Page 41: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 41http://www.emis-kip.ru/prod/ed250

dKs, dbs, dfK

oRIfIce Plates foR floWMeteRsdKs, dbs, dfK

aPPlIcatIonOrifice plates for differential pressure transmitters are used for differential pressure measurement of liquids, steam and gases.

featURes and benefIts• Low cost• no moving parts• Dn from 20mm to 400mm, depending on orifice plate type and

version• process pressure up to 10 Mpa• High reliability • Wireless verification in any regional center for standardization

and metrology

dKs oRIfIce PlatesDKS chamber type orifice plate – is a flat disk with a hole in the center, two chambers (positive and negative) with pipe nipples and sealing gasket.Standard orifice plates have one pair pipe nipples for pressure reducing, but it number can be increased up to 4 pairs on request. Standard orifice plate are available for pipeline Dn=50 to Dn=400mm (GOST 8.563.1, MI2638), with conical entrance, wear resistant (RD 50-411).

flange KIt KfFlanges are used to install orifice plates on pipeline. Flanges are produced according to GOST 12820. Flange kit includes flanges, bolts, screw-nuts, washers and sealing gaskets.

flanged joInt fsDKS orifice plates used with flanged joint provide lower measurement error. Flanges are produced according to GOST 12820, pipe nipples - according to GOST 8.563.1. Flanged joint includes flanges with nipples, bolts, screw-nuts, washers and sealing gaskets. Optional insert ring for installation and testing use is available on request.

dbs oRIfIce PlatesDBS chamberless orifice plate – is flat disk with a hole in the center.Standard orifice plate are available for pipeline Dn=300 to Dn=400mm (GOST 8.563.1, MI2638), wear resistant (RD 50-411).

dfK oRIfIce PlatesDFK – is flanged chamber type orifice plate are available for pipeline Dn=20 to Dn=40mm and nominal pressure up to 10 Mpa. Chamber and flange are represented as a one component part. Orifice plate disk are produced according to RD 50-411, chamber disk according to GOST 8.563.1.Except standard DFK orifice plate, conical entrance type and wear resistant type are also available.

delIVeRY KIt№ Item amount, pcs

1 Orifice plate 1

2Certificate (State verified passport)

1

3Orifice plate calculation signed and stamped by State Verification Officer

1

To make an order to produce an orifice plate, please send us following documents: EMIS questionnaire EMIS-DELTA «Base data for orifice plate calculation», available and requiring equipment list, straight pipe runs scheme.!Attention!

Page 42: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 42 http://www.emis-kip.ru/prod/ev1120

Vessels sU, sR, sK

leVelIng Vessels, sePaRatIon Vessels and condensIng Vessels

leVelIng Vessels sUaPPlIcatIonLeveling vessels are dedicated to maintain stable level of liquid in one of two connection lines during measuring level of liquid in tank using differential pressure sensors.

sePaRatIon Vessels sRaPPlIcatIonSeparation vessels are used to protect inner parts of sensors from direct attack of corrosive fluids. It provide pressure impart through separation liquid.

condensIng Vessels sKaPPlIcatIonCondensing vessels are used in steam flow measurements. It provide equal level of condensed steam in connection lines, which impart differential pressure from orifice plate to sensor.

sPecIfIcatIonsMaterials ..................Alloy 20 stainless steel ( Steel 20) / 12X18H10TMaximum pressure for Su .................................... 6,3 / 25 / 40 MpaMaximum pressure for SR .................................... 6,3 / 25 / 40 MpaMaximum pressure for SK ....................................... 4 / 10 / 40 Mpa

oRdeRIng InfoRMatIonThe example of the order:

1 2 3 4

levelling vessel sU - 6,3 - 2 - А

1 Vessel type

Su Levelling vessel

SR Separation vessel

SK Condensing vessel

X Special order

2 Process pressure

4 pmax=4,0 Mpa

6,3 pmax=6,3 Mpa

10 pmax=10 Mpa

25 pmax=25 Mpa

40 pmax=40 Mpa

X Special order

3 Version

1 Version 1 (standard for SK)

2 Version 2 (standard for SR, Su)

4 Version 4

X Special order

4 Material

St Cast steel (steel 20)

n Stainless steel (12Х18Н10Т GOST 5632)

X Special order

delIVeRY KIt№ Item amount, pcs

1 Vessel according to the order 1

2 Certificate 1

3 package 1

Page 43: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 43http://www.emis-kip.ru/prod/ev1100

eMIs-VeKta 1100

ValVe blocKs foR PRessURe sensoRseMIs-VeKta 1100

eMIs-VeKta 1100-1

aPPlIcatIonSingle-valve blocks are dedicated to be connected to control lines of

gauge pressure sensors, absolute pressure sensors, vacuum-gauge

pressure sensors or expansion pressure sensors. It provide sensor

removal without process shutdown.

eMIs-VeKta 1100-2

aPPlIcatIon2-valve blocks except features of single-valve blocks provide extra

features: pulse line drainage or connection to control gauge, pressure

calibrator or other equipment.

eMIs-VeKta 1100-3

aPPlIcatIon3-valve blocks are dedicated to cut the pressure sensor off

process fluid and for pressure leveling over sensor membrane

during zero point adjustment. Special versions of 3-valve block also

provide:

1. Measurement line drainage to protect sensor chambers

from pollution. (pollution-proof)

2. Double pollution-protection during drainage.

3. Line drainage and control or backup sensor connection.

eMIs-VeKta 1100-5

aPPlIcatIon5-valve blocks provide 3-valve blocks features (pressure sensor cut

off, pressure leveling during zero point adjustment, drainage) and

additional control or backup sensor connection without main sensor

shut off.

№ Item amount, pcs

1EMIS-VEKTA 1100 valve assembly according to the order

1

2 Certificate 1

3 package 1

delIVeRY KIt

sPecIfIcatIonsprocess fluid ......................................... Liquid, steam, gas, oxygen process pressure .............................................................. 40 Mpaprocess fluid temperature ......................................-60°C to +150°CMaterial ..................................................................... 12Х18Н10ТSeals material .................................................................. fluorine Warranty service .......................................................... 36 months

Page 44: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 44 http://www.emis-kip.ru/prod/ev1100

eMIs-VeKta

PRessURe RedUcIng ValVe eMIs-VeKta 1120

aPPlIcatIonDedicated for manometers and pressure sensors mounting to pipelines or vessels. Are used to protect sensors from high temperature stress (overheating) and hydraulic impacts.

sPecIfIcatIonsMaximum process pressure ................................... up to 25 MpaMaximum process temperature .................................up to 200°CConnection type .................................... М20х1.5, G1/2, weldedBase ............................................................Steel weldless pipe nominal diameter .......................................................... 14 mmWall thickness .................................................................. 2 mm

Weldolet eMIs-VeKta 1130/1330aPPlIcatIonWeldolet is a part of pipeline dedicated for connection to thermometers, manometers,

leveling or quality gauges, shut-off valves, pulse lines with process pressure up to 40 Mpa.

Weldolets are weld into pipe to be later connected to:

1130 – valve blocks and valve systems, pressure reducing valves and different types of

pressure sensors

1330 – protection sleeves and different types of temperature sensors

Indication sizes

Version Welding point M d d1 d l l1 l2 R

1130 -M20x1,5

2923,5

7 40 167

-

16 10K1/2”

1330-

M20x1,5 29 23,5 18 40 20 7

M33x2 45 40 31 50 40 5

K1/2” 29 23,5 18,6 40 20 7

BR M33x2 45 40 31 55 40 10 29

PRotectIon sleeVe eMIs-VeKta 1300

aPPlIcatIon protection sleeves are dedicated to mount temperature sensors on pipelines, pressure vessels, steam boilers. They are used to protect sensors from process fluid impact and to provide sensors handling without process shutdown.

protection sleeves have two types specified by it structure features and nominal process pressure:

• Turned solid cylinder type protection sleeve;• Conical protection sleeve.

According to it mounting methods protection sleeves are divided into:

• Threaded;• Welded.

Page 45: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 45http://www.emis-kip.ru/prod/eb60_90

eMIs-bRIZ 60

PUlse PoWeR sUPPlY UnIteMIs-bRIZ 60

aPPlIcatIonpulse power supply units EMIS-BRIZ 60 are primary used in fiscal metering systems, automatic process control systems in district heating substations, heat supply stations, power stations, gas-distributing stations and public utilities providing 24 hour service.

featURes and benefIts• Small sizes and mass• Fault and short circuit alarming• LED indication for each channel• High-drain device supply• Galvanic isolation of outputs

oRdeRIng InfoRMatIon

1 2 3 4 5 6

eMIs-bRIZ 60 - 1 - 24 - 0,75 - 0,03 - s

1 изделия

EMIS-BRIZ 60 pulse power supply unit

2 number of output channels

1 1 channel

3 Power supply

24 24V

X Special order

4 Maximum output current

0,75 0,75A

5 current limiting

- Current limiting is not required

6 fault alarming

St Fault and short circuit alarming

The example of the order:

DIN-rail mounted unit.

sPecIfIcatIonsType .................................................................................pulsenumber of channels ................................................................1power supply ............................. 90 to 246 VAC / 110 to 370 VDCOutput voltage .................................................................... 24VMount .......................................................................... DIn-railAmbient temperature .............................................. -20 to +50°CWater and dust ignition proof .............................................. Ip20

Page 46: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 46 http://www.emis-kip.ru/prod/eb60_90

eMIs-bRIZ 90

tRansfoRMeR PoWeR sUPPlY UnIteMIs-bRIZ 90

aPPlIcatIonTransformer power supply units EMIS-BRIZ 90 are primary used in

different industries to supply non-explosion proof on-field sensors

for general purposes in automatic process control systems, fiscal

metering systems, different rigs and stands.

featURes and benefIts• Channels are overcurrent-proofed and short-circuit-proofed

• Small size

• power supply units don’t create industrial noises

• Galvanic isolation of outputs

• LED indication for each channel

• High reliability

oRdeRIng InfoRMatIon

1 2 3 4 5

eMIs-bRIZ 90 - 2 - 24 - 100 - dIn

1 Наименование изделия

EMIS-BRIZ 90 Transformer power supply unit

2 number of output channels

2 2 channels

4 4 channels

3 Power supply

24 24V

X Special order

4 Maximum output current

100 100 mA

X Special order (50, 80, 120 mA)

5 Mount

- DIn

The example of the order:

According to special order DIn nS35/7.5 is available.

sPecIfIcatIonsType ............................................................................ tarnsformernumber of channels ..................................................................2/4power supply ..................................49 to 51Hz AC / 187 to 242 VDCOutput voltage ............................................................... 24V (±2%)Mount .................................................................................DIn-railAmbient temperature ................................................... -10 to +50°CWater and dust ignition proof ................................................... Ip20

DIN-rail mounted unit.

Page 47: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 47http://www.emis-kip.ru/prod/es750

eMIs-sYsteMa 750

Rs-485 InteRface conVeRteReMIs-sYsteMa 750

IntRInsIc safetY baRRIeRs bIs-a-111-eX

aPPlIcatIonEMIS-SYSTEMA 750 is dedicated for data communication between two gadgets, one of which uses RS-485, another one uses RS-232 or uSB.

featURes & adVantages• Automatically calculate data transfer rate, format and direction • Light indication of data transfer• Galvanic isolation of input and output channels• In-built reverse polarity protection and power and surge protection• Gadgets with different data transfer rate and different formats can be

connected to the same bus

sPecIfIcatIonsType of network ...................................... half-duplex , two wire/two wayInterface 1 ...............................................................................RS-485Interface 2 ................................................................................... uSBTransmission distance ...............................................................1,2 kmTransfer rate .................................................................... 115200 Kbpspower supply ...................................................................through uSBChannel isolation .......................................................................1000 VAmbient temperature .........................................................-20 to +70°CWater and dust ignition proof ........................................................ Ip20

aPPlIcatIonprovides intrinsic safe power supply according to “Requirements for intrinsic safe circuit ib”, pursuant to GOST R 51330.10 comply the requirements for IIB equipment.Matches with EMIS-VIHR 200 ExB version and other instruments with intrinsic safe circuit over 20 mA and 24 V.

sPecIfIcatIonsOpen-circuit voltage ...................................................................................................................25,2 VShort circuit current ..................................................................................................................430mACapacity C0 .......................................................................................................... 0,93 µF (microfarad) Inductance L0 .........................................................................................................................0,87 mHAmbient temperature .........................................................................................................-10 to +50°C

oRdeRIng InfoRMatIon

Item description

EMIS-SYSTEMA 750-RS485-uSB Конвертер физического уровня RS-485 и уровень uSB. Питание от шины uSB

delIVeRY KIt№ Item amount, pcs

1 Converter (according to the order) 1

2 Certificate 1

3 Drivers for uSB on CD 1

4 uSB cable or COM cable (according to the order) 1

Page 48: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 48 Flow measurement and automatization

seRVIces

selectIon, engIneeRIng, sUPeRVIsIng InstallatIon, InstallatIon of eMIs InstRUMents

EMIS Group has been providing engineering, installation, repair

and maintenance services of metering skids for several years. All

services are licensed and certificated.

engIneeRIngOur specialists prepare all the documents and provide approval of

metering skids for natural gas and heat carriers, develop complex

projects according to customer requirements and the operating

conditions.

sUPeRVIsIng InstallatIonHighly qualified specialist with long experience in installation

of EMIS equipment will help you to choose an ideal point for

installation, will consult on connection, setting up and operation

of the whole skid.

Supervising installation service will reduce considerably the time

of process shut-down and will secure from wrong operation.

scadaOur specialists can create a data acquisition system based

on Russian-made or foreign controllers with different SCADA-

systems.

engineering and installation service

phone+7 (351) 729-99-12 (multichannel) Cellphone: +7 (919) 303-00-12 [email protected]

Warranty period will be doubled if order supervising installation service!!Attention!

Page 49: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

page 49Flow measurement and automatization

seRVIces

Metrology department

+7 (351) 729-99-12 (multichannel)+7 (351) 729-99-13 (fax)

+7 (912) 899-07-70 [email protected]

VeRIfIcatIon of lIQUId floWMeteRs

descRIPtIonAutomatic calibration rig for liquids provide calibration and verification of flowmeters with counter, electronic transmitter, frequency, pulse or analog output signals, using volumetric or mass measuring principle.

sPecIfIcatIonsFlow range ..................................................................0,01 – 100 m3/hprocess liquid .............................. water according to GOST R51232-98process pressure ...........................................................up to 0,4 MpaFlowmeter Dn ................................................................ 15 to 100 mmVerification methods ..........................................standard meter / massnumber of standard meters ...............................................................3number of testing meters ..........................................................up to 8Metrological characteristics ..............................................see the table

MetRologIcal cHaRacteRIstIcs of VeRIfIcatIon facIlItY

accuracy Pulse metering

channelanalog metering

channel

Accuracy for volume (mass) flow measurements (mass method) ±0,05% ±0,07%

Accuracy for volume (mass) flow measurements (standard meter verification method) ±0,25% ±0,26%

Accuracy for temperature measurements ±0,05 оС

Accuracy of automatic setup ±5%

Root-mean-square deviation not more than ±0,2%

oRdeRIng PRocedUReTo order verification service, please provide following information:

1. Flowmeter type (vortex, magnetic (electromagnetic), chamber type etc.)2. The name of flowmeter manufacturing company3. Model of flowmeter4. Dn5. Flow range6. Accuracy class7. Output signals8. Verification procedure

Verification is proceeding in presence of Chelyabinsk Center for Standardization, Metrology and Certification official representative. !Issuing documents

Page 50: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

catalogUe-2014

page 50

QuESTIOnnAIRE FOR FLOWMETER*

Flow measurement and automatization

To get a quotation, please fill in EMIS questionnaire and send it to dealer office close to your region or directly to our head office.

customer information

Company CityCustomer name and official capacity Datephone / fax: E-mail:Indicate requiring number of instruments

applicationprocess fluid Gas Steam Liquid name of fluid (composition)process descriptionRequiring accuracyType of metering General purposes Fiscal metering

Process parametersMinimum nominal Maximum

Flow range (for gases, please underline as appropriate: process / normal)pressure (please underline as appropriate: absolute / gauge) process fluid temperatureDensity Viscosity

Mounting pointMounting point descriptionpipe inner diameter pipe materialStraight pipe length upstream Downstream Ambient temperatureExplosion-proof requirements (specify marking)

Requiring type of flowmeter

Vortex flowmeter EMIS-VIHR Metal rotameter EMIS-META Electronic flowmeter EMIS-pLAST

Magnetic flowmeter EMIS-MAG plastic rotameter EMIS-METAElectronic flowmeter with integrated flow controller EMIS-pLAST-R

Rotor flowmeter EMIS-DIO Mass EMIS-MASS Ask specialist

How did you hear about eMIs?

Our dealer Our manager Engineering company

Trade show print publication Internet

Process-wetted material

Cast steel Stainless steel Special order Ask specialist

connection type

Frequency signal HARTAnalog signal 4-20 mA, Modbus

Connection to pC or other digital equipment

Positions required

Only flowmeterFlowmeter with optional equipment

Metering skid

services required

Engineering Supervising installation Installation and commissioning

description for optional equipment

Connection kit High level software Testing instruments

Meter runs Insert pipe Ask specialist

description for metering skid

Computing device power supply unit Complete skid

pressure sensor Valve block Vandal-proof closet

Temperature sensor protection sleeve Ask specialist

contact our regional dealers or head office

Head office+7 (351) 729-99-12 (multichannel)+7 (351) 729-99-13 (fax)

[email protected]

*Questionnaires for gas regulating, associated equipment and other see on www.emis-kip.ru

Page 51: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,
Page 52: CATALOGUE - ЭМИСEMIS-VEKTA VT200 Insert pipes for installation use EMIS-VIHR 200.KIp Cable kit for simulation diagnostic needs EMIS-BRIZ power supply unit floW Ranges* dn, mm liquids,

CATALOGUE

2014Group of industrial companies «EMIS»

www.emis-kip.ru

Flowmeters

Measurement systems

Metering skids

Filters

Associated equipment

454007, RUSS IA,

Che lyab insk , U l . Kommuny, 35 , off ice 13

Telephone: +7 (351) 729-99-12 (mul t ichanne l )

Fax : +7 (351) 729-99-13

E-mai l : sa les@emis -k ip . ru

EMIS Group Techn ica l Support Serv iceTe lephone: +7 (351) 729-99-12 (741)E-mai l : support@emis -k ip . ru

g skidskids

dedd

kkids

ntnttntnteocso iatc teoccAsso edeed menm nequipmeq pmiptoo iatc teocc ed ee menequipme pmi