caution — read carefully · 2016. 6. 30. · • the style drawer series has been listed by etl...
TRANSCRIPT
![Page 1: CAUTION — READ CAREFULLY · 2016. 6. 30. · • The Style Drawer Series has been listed by ETL and complies with UL 962a. when installed in accordance with these instructions](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145ba0907bb162e665fdf26/html5/thumbnails/1.jpg)
Docking DrawerInstall Manual for Style Drawer Series
Applicable Models: 0290-00013(W) / 24 0290-00011(W) / 21 0290-00049(W) / 18
CAUTION — READ CAREFULLY
• Failure to follow these instructions can cause death or permanent injury. Do not work on live electrical circuits! Make absolutely certain power is off before connecting the device!
• Thereareinstructionsprovidedwiththeelectricaloutlet–readthose instructionsinadditiontothese.
• Thisproductisfordry,indoorandpermanentinstallationsonly.
• Installthedeviceinaccordancewithallnationalandlocalelectricalcodes.
General Information–
• TheStyleDrawerSerieshasbeenlistedbyETLandcomplieswithUL962a when installed in accordance with these instructions. Do not install this product in a manner contrary to these instructions.
• Itistheinstaller’sresponsibilitytomakesurethatpowersuppliedtothejunction boxconformstoallapplicablebuildingcodesandstandards.
• TheStyleDrawerProductsmustbeconnectedtoa20Acircuitusing12AWGwire.
Pleasevisitwww.dockingdrawer.comandclickontheSpecificationbutton.
Structure–
Junction Box
Receptacle Box
Thermostat Reset
GFCI Outlet
Arm Mechanism
0230-00002.r7
2/22/2016
1
![Page 2: CAUTION — READ CAREFULLY · 2016. 6. 30. · • The Style Drawer Series has been listed by ETL and complies with UL 962a. when installed in accordance with these instructions](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145ba0907bb162e665fdf26/html5/thumbnails/2.jpg)
Top View of Style Drawer, Mounted
Side View of Style Drawer, Mounted
MINIMUMWIDTHBEHINDDRAWERBOX
StyleDrawer24 / 0290-00013(W)= ≥ 13 1/2"
StyleDrawer21 / 0290-00011(W)= ≥ 12"
StyleDrawer18 / 0290-00049(W)= ≥ 10 1/2"
2
Preparing for a Style Drawer Installation–To prepare for a successful Style Drawer installation please ensure that the cable management arms are free and unobstructed by confirming following the specifications:
• Theminimumwidthbehinddrawerboxmust beatleast: 131/2"forStyleDrawer24 12"fortheStyleDrawer21 10 1/2"forStyleDrawer18
• Thedistancefromthebackofthedrawertothewallwherethejunctionboxmountsmustbeatleast4"asshown.
• Lineupthejunctionboxandreceptacleboxasshown.
• Thecutoutforthereceptacleboxshouldbe5.95"widex2.8"high.Enlargingthecutoutby1/16"ineachdimensionisacceptableforeaseofmounting.Theinstallermustprovide(4)mountingscrewsforthereceptaclebox.
• Theminimuminteriordrawerboxheightmustbe atleast4"
• Thereceptacleboxacceptsdrawerwallthicknessesofeither1/2"or5/8".
• Thedrawerslidesmustbepositionedinsuchas waythatthedrawerextendsnomorethan:
20"fortheStyleDrawer24 17"fortheStyleDrawer21 14"fortheStyleDrawer18.
Furtherextensionwillplacealoadonthearm mechanism.
• Ensure that the arm mechanism is free and unobstructed.
![Page 3: CAUTION — READ CAREFULLY · 2016. 6. 30. · • The Style Drawer Series has been listed by ETL and complies with UL 962a. when installed in accordance with these instructions](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145ba0907bb162e665fdf26/html5/thumbnails/3.jpg)
3
Installing the Style Drawer Outlet–
1. Withthedrawerclosedandthereceptacleboxinposition,markthelocationoftherearmountingbracketsothatthearmsarecentered.
2.InsertStyleDraweroutletthroughthereceptacle boxcutoutinthebackofthedrawer.
4.Installtherightrearmountingscrew (notsupplied).
5.Mountthereceptaclebox.
6.Testmovement.Aligncablemanagementarmssotheyarecenteredbetweenthedrawerboxandthebackofthecabinetifnecessary.
7. ConnectelectricalsupplytotheStyleDraweroutletaccordingtothewiringdiagramon page5.
3.ExtendtheStyleDraweroutletandinstallthe leftrearmountingscrew(notsupplied).
![Page 4: CAUTION — READ CAREFULLY · 2016. 6. 30. · • The Style Drawer Series has been listed by ETL and complies with UL 962a. when installed in accordance with these instructions](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145ba0907bb162e665fdf26/html5/thumbnails/4.jpg)
4
Removing the Receptacle Box–ForasuccessfulStyleDraweroutletinstallation,itisNOTnecessarytoremovethereceptacleboxfromthecablemanagementarms.However,ifthereceptacleboxneedstoberemoved,pleasefollowthesestepstodisconnect/reconnectthereceptacleboxfromthecablemanagementarms.
1.Removethearmmechanismground connectioninsidethereceptacleboxby removingthegreengroundscrewandring terminalasshown.
4.Mountthejunctionboxinthecorrectlocationonthebackwallbehindthedrawerasshown inthedrawing.
5. Installthedrawerinthecabinet,andholdontotheendofthearmmechanism.
6.Passthewiresfromthearmmechanismintothereceptacleboxandreattachthebracketusingthe(3)#10Philipsheadscrews.
7.Securethereceptacleboxtothebackofthedrawerusingtheinstallersuppliedhardware.
8. Reconnecttheblackwirefromthethermostattotheblackwirefromthearmmechanismusingthewirenut.Make sure the thermostat is connected in series with the line (black) wire.
9. DO NOT FORGET TO REATTACH THE GROUND WIRE INSIDE THE RECEPTACLE BOX. TORQUE SCREW TO 16-18 IN-LBS. ENSURE THAT THE THERMOSTAT IS WIRED IN SERIES WITH THE LINE (BLACK) WIRE. SEE WIRE DIAGRAM.
2.Removetheyellowwirenutconnecting theblackwirefromthearmmechanismto theblackwiregoingtothethermostat.
3.Removethe(3)#10Phillipsheadscrews frominsidethereceptaclebox.Thiswill allowthearmmechanismbrackettobe disconnectedfromthereceptaclebox.
MAKE SURE BOTH GROUND SCREWS ARE SECURELY CONNECTED!
TORQUE TO 28-32 IN-LBS
DO NOT REMOVE THIS WIRE
![Page 5: CAUTION — READ CAREFULLY · 2016. 6. 30. · • The Style Drawer Series has been listed by ETL and complies with UL 962a. when installed in accordance with these instructions](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145ba0907bb162e665fdf26/html5/thumbnails/5.jpg)
Junction Box Wiring
Reset Button
5
Reinstalling the Outlet– Install the GFCI outlet in the receptacle box before
connecting the junction box to electrical power.
•Afterthereceptacleboxhasbeencorrectlyinstalled inthebackofthedrawerand(ifapplicable)allwires correctlyreattached,theGFCIoutletcanbeinstalled.
REMINDER: IF THE ARM MECHANISM TO RECEPTACLE BOX GROUND WIRE WAS REMOVED DURING INSTALLATION, MAKE SURE IT HAS BEEN REATTACHED AND TORQUED PROPERLY. MAKE SURE THE THERMOSTAT IS WIRED IN SERIES WITH THE LINE (BLACK) WIRE. SEE WIRING DIAGRAM.
• FollowtheGFCIoutletinstructions(includedinoutletpackaging)andconnecttheblack,white,andgreenwiresinaccordancewiththoseinstructions.
Specifications– StyleDrawerTechnicalSpecifications:
• ACPower:20A125V,tamperresistantGFCIwithLEDindicator
• Thermostattriprange:100˚–120˚ F
• Maxratedcurrent@125VAC:20A.Circuitisprotectedby manuallyresettablethermostataccessiblefromtheuserside.
Operation– InstructionsspecifictotheGFCIoutlet areincludedwiththeoutletitself.
• TheStyleDrawerincludesa100˚–120˚Fresettablethermostatto protectagainstoverheatinginsidethedrawer.Toreset,correctthesource ofovertemperatureandpushtheredthermostatbutton.Noteyoumayneedtowaitafewminutesfortheunittocoolbeforethethermostatcanbereset.
• TheGFCIoutlethasagreenLEDwhichwilllightifthereispowertothe outlet.IftheLEDisnotlit,checktheGFCIresetbuttonandthethermostat.
Wiring Diagrams–
Receptacle Box Wiring
Green Wire (ground): green screw
White Wire (neutral): silver screw
Black Wire (line): brass screw
![Page 6: CAUTION — READ CAREFULLY · 2016. 6. 30. · • The Style Drawer Series has been listed by ETL and complies with UL 962a. when installed in accordance with these instructions](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145ba0907bb162e665fdf26/html5/thumbnails/6.jpg)
Specificationssubjecttochange.Pleasevisitwww.dockingdrawer.comforthemostcurrentinformation.
121615
12893 Alcosta Blvd., Suite M, San Ramon, CA 94583
p 530.205.3625 | f 925.886.3824 | e [email protected]
www.dockingdrawer.com Member
6
Docking Drawer™
Application: CHARGING POWERING
Outlet Type Docking Drawer Slim (2-AC, 2-USB) Docking Drawer Slim USB (4-USB) Style Drawer (2-AC/GFCI) Style Drawer Flush (2-AC/GFCI)
Cabinet Depth ≤ 24" ≤ 21" ≤ 18" ≤ 24" ≤ 21" ≤ 18" ≤ 24" ≤ 21" ≤ 18" ≤ 24" ≤ 21" ≤ 18"
Outlet NameDocking Drawer 24 Slim
Docking Drawer 21 Slim
Docking Drawer 18 Slim
Docking Drawer 24 Slim USB
Docking Drawer 21 Slim USB
Docking Drawer 18 Slim USB
Style Drawer
24
Style Drawer
21
Style Drawer
18
Style Drawer
24 Flush
Style Drawer 21 Flush
Style Drawer 18 Flush
Part Number (White)0290-
00031 (W)0290-
00030 (W)0290-
00047 (W)0290-
00046 (W)0290-
00045 (W)0290-
00048 (W)0290-
00013 (W)0290-
00011 (W)0290-
00049 (W)0290-
00033 (W)0290-
00032 (W)0290-
00050 (W)
Cabinet Specifications:
Maximum drawer extension
21" 18" 15" 21" 18" 15" 20" 17" 14" 20" 17" 14"
Minimum width behind drawer box
≥171/2" ≥16" ≥ 14 1/2" ≥171/2" ≥16" ≥ 14 1/2" ≥ 13 1/2" ≥ 12" ≥ 10 1/2" ≥ 13 1/2" ≥ 12" ≥ 10 1/2"
Minimum space behind drawer box
3" 3" 3" 3" 3" 3" 4" 4" 4" 5" 5" 5"
Minimum interior drawer box height
2 3/4" 2 3/4" 2 3/4" 2 3/4" 2 3/4" 2 3/4" 4" 4" 4" 4" 4" 4"
Charging Receptacle Specifications:
Tamper Resistant Yes NA NA NA
120V AC Outlets 2 0 NA NA
USB Ports 2 4 NA NA
Max CurrentAC:3amps@120VAC USB:3.6amps@5VDC
USB4.2amps@5VDC NA NA
Powering Receptacle Specifications:
Tamper Resistant NA NA Yes Yes
120V AC Outlets NA NA 2 2
GFCI NA NA Yes Yes
LED Indicator NA NA Yes Yes
Max Current NA NA 20amps 20amps
Features:
ETL Listed to UL962a Yes Yes Yes Yes
ETL Listed to CSA-22.2
No Yes No No
Interlocking Safety Feature
CircuitBreaker CircuitBreaker ManualResetThermostat ManualResetThermostat
Electrical Connection
NEMA5-15P NEMA5-15P Hardwired Hardwired
Warranty 1Year 1Year 1Year 1Year
TEST
RESET
TEST
RESET