caution — read carefully · 2016. 6. 30. · • the style drawer series has been listed by etl...

6
Docking Drawer Install Manual for Style Drawer Series Applicable Models: 0290-00013(W) / 24 0290-00011(W) / 21 0290-00049(W) / 18 CAUTION — READ CAREFULLY Failure to follow these instructions can cause death or permanent injury. Do not work on live electrical circuits! Make absolutely certain power is off before connecting the device! • There are instructions provided with the electrical outlet – read those instructions in addition to these. • This product is for dry, indoor and permanent installations only. • Install the device in accordance with all national and local electrical codes. General Information– • The Style Drawer Series has been listed by ETL and complies with UL 962a when installed in accordance with these instructions. Do not install this product in a manner contrary to these instructions. • It is the installer’s responsibility to make sure that power supplied to the junction box conforms to all applicable building codes and standards. • The Style Drawer Products must be connected to a 20A circuit using 12 AWG wire. Please visit www.dockingdrawer.com and click on the Specification button. Structure– Junction Box Receptacle Box Thermostat Reset GFCI Outlet Arm Mechanism 0230-00002 . r7 2/22/2016 1

Upload: others

Post on 23-Aug-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CAUTION — READ CAREFULLY · 2016. 6. 30. · • The Style Drawer Series has been listed by ETL and complies with UL 962a. when installed in accordance with these instructions

Docking DrawerInstall Manual for Style Drawer Series

Applicable Models: 0290-00013(W) / 24 0290-00011(W) / 21 0290-00049(W) / 18

CAUTION — READ CAREFULLY

• Failure to follow these instructions can cause death or permanent injury. Do not work on live electrical circuits! Make absolutely certain power is off before connecting the device!

• Thereareinstructionsprovidedwiththeelectricaloutlet–readthose instructionsinadditiontothese.

• Thisproductisfordry,indoorandpermanentinstallationsonly.

• Installthedeviceinaccordancewithallnationalandlocalelectricalcodes.

General Information–

• TheStyleDrawerSerieshasbeenlistedbyETLandcomplieswithUL962a when installed in accordance with these instructions. Do not install this product in a manner contrary to these instructions.

• Itistheinstaller’sresponsibilitytomakesurethatpowersuppliedtothejunction boxconformstoallapplicablebuildingcodesandstandards.

• TheStyleDrawerProductsmustbeconnectedtoa20Acircuitusing12AWGwire.

Pleasevisitwww.dockingdrawer.comandclickontheSpecificationbutton.

Structure–

Junction Box

Receptacle Box

Thermostat Reset

GFCI Outlet

Arm Mechanism

0230-00002.r7

2/22/2016

1

Page 2: CAUTION — READ CAREFULLY · 2016. 6. 30. · • The Style Drawer Series has been listed by ETL and complies with UL 962a. when installed in accordance with these instructions

Top View of Style Drawer, Mounted

Side View of Style Drawer, Mounted

MINIMUMWIDTHBEHINDDRAWERBOX

StyleDrawer24 / 0290-00013(W)= ≥ 13 1/2"

StyleDrawer21 / 0290-00011(W)= ≥ 12"

StyleDrawer18 / 0290-00049(W)= ≥ 10 1/2"

2

Preparing for a Style Drawer Installation–To prepare for a successful Style Drawer installation please ensure that the cable management arms are free and unobstructed by confirming following the specifications:

• Theminimumwidthbehinddrawerboxmust beatleast: 131/2"forStyleDrawer24 12"fortheStyleDrawer21 10 1/2"forStyleDrawer18

• Thedistancefromthebackofthedrawertothewallwherethejunctionboxmountsmustbeatleast4"asshown.

• Lineupthejunctionboxandreceptacleboxasshown.

• Thecutoutforthereceptacleboxshouldbe5.95"widex2.8"high.Enlargingthecutoutby1/16"ineachdimensionisacceptableforeaseofmounting.Theinstallermustprovide(4)mountingscrewsforthereceptaclebox.

• Theminimuminteriordrawerboxheightmustbe atleast4"

• Thereceptacleboxacceptsdrawerwallthicknessesofeither1/2"or5/8".

• Thedrawerslidesmustbepositionedinsuchas waythatthedrawerextendsnomorethan:

20"fortheStyleDrawer24 17"fortheStyleDrawer21 14"fortheStyleDrawer18.

Furtherextensionwillplacealoadonthearm mechanism.

• Ensure that the arm mechanism is free and unobstructed.

Page 3: CAUTION — READ CAREFULLY · 2016. 6. 30. · • The Style Drawer Series has been listed by ETL and complies with UL 962a. when installed in accordance with these instructions

3

Installing the Style Drawer Outlet–

1. Withthedrawerclosedandthereceptacleboxinposition,markthelocationoftherearmountingbracketsothatthearmsarecentered.

2.InsertStyleDraweroutletthroughthereceptacle boxcutoutinthebackofthedrawer.

4.Installtherightrearmountingscrew (notsupplied).

5.Mountthereceptaclebox.

6.Testmovement.Aligncablemanagementarmssotheyarecenteredbetweenthedrawerboxandthebackofthecabinetifnecessary.

7. ConnectelectricalsupplytotheStyleDraweroutletaccordingtothewiringdiagramon page5.

3.ExtendtheStyleDraweroutletandinstallthe leftrearmountingscrew(notsupplied).

Page 4: CAUTION — READ CAREFULLY · 2016. 6. 30. · • The Style Drawer Series has been listed by ETL and complies with UL 962a. when installed in accordance with these instructions

 

4

Removing the Receptacle Box–ForasuccessfulStyleDraweroutletinstallation,itisNOTnecessarytoremovethereceptacleboxfromthecablemanagementarms.However,ifthereceptacleboxneedstoberemoved,pleasefollowthesestepstodisconnect/reconnectthereceptacleboxfromthecablemanagementarms.

1.Removethearmmechanismground connectioninsidethereceptacleboxby removingthegreengroundscrewandring terminalasshown.

4.Mountthejunctionboxinthecorrectlocationonthebackwallbehindthedrawerasshown inthedrawing.

5. Installthedrawerinthecabinet,andholdontotheendofthearmmechanism.

6.Passthewiresfromthearmmechanismintothereceptacleboxandreattachthebracketusingthe(3)#10Philipsheadscrews.

7.Securethereceptacleboxtothebackofthedrawerusingtheinstallersuppliedhardware.

8. Reconnecttheblackwirefromthethermostattotheblackwirefromthearmmechanismusingthewirenut.Make sure the thermostat is connected in series with the line (black) wire.

9. DO NOT FORGET TO REATTACH THE GROUND WIRE INSIDE THE RECEPTACLE BOX. TORQUE SCREW TO 16-18 IN-LBS. ENSURE THAT THE THERMOSTAT IS WIRED IN SERIES WITH THE LINE (BLACK) WIRE. SEE WIRE DIAGRAM.

2.Removetheyellowwirenutconnecting theblackwirefromthearmmechanismto theblackwiregoingtothethermostat.

3.Removethe(3)#10Phillipsheadscrews frominsidethereceptaclebox.Thiswill allowthearmmechanismbrackettobe disconnectedfromthereceptaclebox.

MAKE SURE BOTH GROUND SCREWS ARE SECURELY CONNECTED!

TORQUE TO 28-32 IN-LBS

 

 

 

DO NOT REMOVE THIS WIRE

Page 5: CAUTION — READ CAREFULLY · 2016. 6. 30. · • The Style Drawer Series has been listed by ETL and complies with UL 962a. when installed in accordance with these instructions

Junction Box Wiring

Reset Button

5

Reinstalling the Outlet– Install the GFCI outlet in the receptacle box before

connecting the junction box to electrical power.

•Afterthereceptacleboxhasbeencorrectlyinstalled inthebackofthedrawerand(ifapplicable)allwires correctlyreattached,theGFCIoutletcanbeinstalled.

REMINDER: IF THE ARM MECHANISM TO RECEPTACLE BOX GROUND WIRE WAS REMOVED DURING INSTALLATION, MAKE SURE IT HAS BEEN REATTACHED AND TORQUED PROPERLY. MAKE SURE THE THERMOSTAT IS WIRED IN SERIES WITH THE LINE (BLACK) WIRE. SEE WIRING DIAGRAM.

• FollowtheGFCIoutletinstructions(includedinoutletpackaging)andconnecttheblack,white,andgreenwiresinaccordancewiththoseinstructions.

Specifications– StyleDrawerTechnicalSpecifications:

• ACPower:20A125V,tamperresistantGFCIwithLEDindicator

• Thermostattriprange:100˚–120˚ F

• Maxratedcurrent@125VAC:20A.Circuitisprotectedby manuallyresettablethermostataccessiblefromtheuserside.

Operation– InstructionsspecifictotheGFCIoutlet areincludedwiththeoutletitself.

• TheStyleDrawerincludesa100˚–120˚Fresettablethermostatto protectagainstoverheatinginsidethedrawer.Toreset,correctthesource ofovertemperatureandpushtheredthermostatbutton.Noteyoumayneedtowaitafewminutesfortheunittocoolbeforethethermostatcanbereset.

• TheGFCIoutlethasagreenLEDwhichwilllightifthereispowertothe outlet.IftheLEDisnotlit,checktheGFCIresetbuttonandthethermostat.

Wiring Diagrams–

Receptacle Box Wiring

 

 

 

Green Wire (ground): green screw

White Wire (neutral): silver screw

Black Wire (line): brass screw

Page 6: CAUTION — READ CAREFULLY · 2016. 6. 30. · • The Style Drawer Series has been listed by ETL and complies with UL 962a. when installed in accordance with these instructions

Specificationssubjecttochange.Pleasevisitwww.dockingdrawer.comforthemostcurrentinformation.

121615

12893 Alcosta Blvd., Suite M, San Ramon, CA 94583

p 530.205.3625 | f 925.886.3824 | e [email protected]

www.dockingdrawer.com Member

6

Docking Drawer™

Application: CHARGING POWERING

Outlet Type Docking Drawer Slim (2-AC, 2-USB) Docking Drawer Slim USB (4-USB) Style Drawer (2-AC/GFCI) Style Drawer Flush (2-AC/GFCI)

Cabinet Depth ≤ 24" ≤ 21" ≤ 18" ≤ 24" ≤ 21" ≤ 18" ≤ 24" ≤ 21" ≤ 18" ≤ 24" ≤ 21" ≤ 18"

Outlet NameDocking Drawer 24 Slim

Docking Drawer 21 Slim

Docking Drawer 18 Slim

Docking Drawer 24 Slim USB

Docking Drawer 21 Slim USB

Docking Drawer 18 Slim USB

Style Drawer

24

Style Drawer

21

Style Drawer

18

Style Drawer

24 Flush

Style Drawer 21 Flush

Style Drawer 18 Flush

Part Number (White)0290-

00031 (W)0290-

00030 (W)0290-

00047 (W)0290-

00046 (W)0290-

00045 (W)0290-

00048 (W)0290-

00013 (W)0290-

00011 (W)0290-

00049 (W)0290-

00033 (W)0290-

00032 (W)0290-

00050 (W)

Cabinet Specifications:

Maximum drawer extension

21" 18" 15" 21" 18" 15" 20" 17" 14" 20" 17" 14"

Minimum width behind drawer box

≥171/2" ≥16" ≥ 14 1/2" ≥171/2" ≥16" ≥ 14 1/2" ≥ 13 1/2" ≥ 12" ≥ 10 1/2" ≥ 13 1/2" ≥ 12" ≥ 10 1/2"

Minimum space behind drawer box

3" 3" 3" 3" 3" 3" 4" 4" 4" 5" 5" 5"

Minimum interior drawer box height

2 3/4" 2 3/4" 2 3/4" 2 3/4" 2 3/4" 2 3/4" 4" 4" 4" 4" 4" 4"

Charging Receptacle Specifications:

Tamper Resistant Yes NA NA NA

120V AC Outlets 2 0 NA NA

USB Ports 2 4 NA NA

Max CurrentAC:3amps@120VAC USB:3.6amps@5VDC

USB4.2amps@5VDC NA NA

Powering Receptacle Specifications:

Tamper Resistant NA NA Yes Yes

120V AC Outlets NA NA 2 2

GFCI NA NA Yes Yes

LED Indicator NA NA Yes Yes

Max Current NA NA 20amps 20amps

Features:

ETL Listed to UL962a Yes Yes Yes Yes

ETL Listed to CSA-22.2

No Yes No No

Interlocking Safety Feature

CircuitBreaker CircuitBreaker ManualResetThermostat ManualResetThermostat

Electrical Connection

NEMA5-15P NEMA5-15P Hardwired Hardwired

Warranty 1Year 1Year 1Year 1Year

TEST