  • Chalmit Lighting January 2009 Revision 1

    Contents Chalmlite Version 4.04 - Minimum Requirements ........................................3

    To Install: .........................................................................................................3

    Project Set-Up .................................................................................................5

    Project Set-Up .................................................................................................5

    Snap Values ....................................................................................................7

    Target Grids.....................................................................................................9

    Icon Method - Definition.................................................................................14

    Icon Method - Placement...............................................................................19

    Floodlight Method - Definition ........................................................................23

    Floodlight Method - Placement ......................................................................26

    Luminaire Control & Zoom.............................................................................32

    My First Room ...............................................................................................40

    Lighting the room & Reflections.....................................................................47

    Predefined room shapes ...............................................................................59

    Drawing rooms & Ceilings .............................................................................63

    Emergency Luminaires..................................................................................69

  • Chalmit Lighting March 2010 Revision 2

    3

    Chalmlite Version 4.04 - Minimum Requirements October 2007 Any P.C. presently running Windows 95, 98, 2000, XP or N.T.4 (Chalmlite will not run on Windows 3.1x) H.D. spare capacity: 150 Mb RAM 32 Mb Screen Resolution 1024x768 Screen Colour True Color 32(bit) Fonts Small Printer Any Windows is using (preferably colour)

    To Install: From the START button go to RUN and type D: SETUP.EXE (or whatever your CD drive letter is) Follow the instructions Setup will give the choice of either accepting the default path for Chalmlite location (C:\CHALMLITEV4.04) or choosing a different path location. The final question from Setup allows you to have an Icon shortcut placed on your desktop. If you choose not to do this you can operate Chalmlite from the Start Programs menu bar. The configuration file is CMW.CFG. located in the Chalmlite Directory It contains the Pathnames of the following Folders:- Photo (contains the I.E.S. database photometric files) Projects (contains the project files with *.IN extension) Pictures (contains BMP files of Chalmit products and the Printout.txt file) Note: The last three pathnames require trailing back slashes.

  • Chalmit Lighting March 2010 Revision 2

    4

    If you move any of the above folders after installation the CMW.CFG pathnames should be changed to suit. In addition, Set-up loads two other folders: Help (this contains all of Chalmlite Help files in HTML format) Backup (this holds any files that have been overwritten if you re-install Chalmlite over an existing installation) Two validation documents (Val-ext-v4.pdf and Val-int-v4.pdf) can be found in the Help file folder, simply follow the links on the index page when you launch help. These testify to the accuracy of the Chalmlite program for Exterior and Interior Calculations. Chalmlite Version 4.04 can be installed onto and accessed via a Network server but is not itself a true Net-workable program. Two users cannot access the program at the same time. Alternatively Chalmlite may be installed onto individual PCs and the Project Files saved to a Network location for security purposes.

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting January 2009 Revision 1

    5

    Project Set-Up The first stage of any lighting design is to create a new project. To do this follow the steps outlined below.

    You can create a new project by clicking the Projects button.

    Creating a new project.

    o Select File o Select New

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    6

    New Project Settings

    o Job/Project Save Location - You must choose the file directory to save this project to. o Enter FILENAME o Enter PROJECT NAME (if applicable) o Enter SITENAME (if applicable) o Enter ENGINEER (if applicable)

    Define Limits window - You must now determine the working area

    o Enter Width of area o Enter Length of area

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    7

    Snap Values Snap Values are the term used to determine where the mouse will be operating from on the page.

    The lower right hand corner that is highlighted area shows the use positioning of the mouse on the working area.

    Select Snap menu from the toolbar

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    8

    Snap - the snap value determines the frequency in metres the mouse is snapping in the working area

    o Snap Status remain on o Snap Value measurement in metres

    The lower right hand corner that is highlighted area shows the use positioning of the mouse on the working area.

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    9

    Target Grids The Target Grid enables You to calculate the lighting levels represented on the project being created.

    Select Target Grid menu from toolbar

    o Define new grid o New x-y grid

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    10

    The New x-y grid window opens and enables You to determine the proximity for each point.

    Target Grid

    o Left click on the grid to place the first corner on the Target Grid o Click on the opposite corner to secure the grid area

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    11

    The Target Grid has now been created displayed here with a selection of grid numbers representing the

    light levels at specific

    The above illustration illustrates how You can manipulate the target grid area to be worked on by deletion of points on the grid. Select Target Grid menu from toolbar

    o Delete points from inside a polygon

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    12

    Delete points from inside a polygon

    o Left click on target grid to create the first deletion point o Left click on target grid to create the second deletion point o Left click on target grid to create the third deletion point

    Delete points from inside a polygon

    o Right click on the first deletion point to complete the area to be deleted. o Click Yes to complete the deletion process

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    13

    Shown above is the area deleted from the target area

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    14

    Icon Method - Definition The Icon Method enables You to choose the luminaire type used in the project.

    Select Luminaires menu from the toolbar

    o Icon method o Define luminaire

    Define current luminaire icon window opens

    This enables the use to choose the symbol they would prefer to use for their luminaire

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    15

    Define current luminaire window opens

    You can click the icon to be used to signify the luminaire.

    Select Luminaire window opens

    o You can select the correct category to choose their luminaire o Click OK to continue

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    16

    Select Luminaire window opens

    o You can determine in the illustration above the degree of safety required for the project to be created o Click OK to continue

    Select Luminaire window opens

    o You can determine the luminaire type to be used in the project. o Click OK to continue

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    17

    Select Luminaire window opens

    o You can now choose the product model within the Fluorescent range to be used in the project. o Click OK to continue

    Select Luminaire window opens

    o You can now choose the product specification within the fluorescent range to be used in the project. o Click OK to continue

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    18

    Define current luminaire icon window opens

    o Click Edit current description Define current luminaire icon window

    o Set luminaire parameters window opens Here You can determine the mounting height, tilt, etc

    o Click OK to continue

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    19

    Click OK to complete the process

    Icon Method - Placement The Icon Method of placement enables You to place some luminaire icons onto the predetermined working area

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    20

    The highlighted area on the toolbar indicates how You can locate a luminiare. Click the Locate luminaire button

    The highlighted area on this page is reminding You that they must now specify the (x-y) co-ordinates of the

    luminaire chosen earlier.

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    21

    Specify luminaire location button from the toolbar

    o Left click to specify luminaire location o Move the mouse in the direction you want to aim the luminaire o Right click to complete the process

    > The illustration above highlights the position chosen by You for the luminaire

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    22

    > Select the Copy luminaire button from the toolbar to proceed with copying existing luminaire

    Copying a luminaire on Target Grid Left click the existing luminaire on the target grid Left click each of the locations where You would want copy the existing luminaire Right click the Target Grid to finish copying the luminaire Right click to complete the process

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    23

    Floodlight Method - Definition The Floodlight Method by definition enables You to define the characteristics of the floodlight luminare.

    Select Luminaires menu from the toolbar

    o Select Floodlight method o Left click to select Define floodlight menu item

    Pick current beam pattern window opens

    o Select colour to represent different luminaires o Click Choose floodlight button

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    24

    Select Luminaire window opens

    o You can select the correct category to choose their luminaire o Click OK to continue

    Select Luminaire window opens

    o You can determine in the illustration above the degree of safety required for the project to be created o Click OK to continue

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    25

    Select Luminaire window opens o You can determine the luminaire type to be used in the project. o Click OK to continue

    Select Luminaire window opens

    o You can now choose the product specification within the Fluorescent range to be used in the project. o Click OK to continue

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    26

    Pick current beam pattern window opens

    o Click OK to continue and complete this process

    Floodlight Method - Placement The Floodlight Method by placement enables You to define the position of the floodlight luminaire within a project.

    Select Locate floodlight button from the menu

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    27

    Click on the Target Grid where the use would like to place the mounting location

    The highlighted area on this page is reminding You that they must now specify the mounting height of the

    luminaire

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    28

    Right click on the Target Grid to complete placing the mounting location

    Shown above in this illustration indicates to You where the mounting point is situated on the target grid.

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    29

    Select Aim current floodlight button from the toolbar to stipulate where the luminaire is to direct the light

    output

    Left click on the mounting point to begin the process in aiming the luminaire light output

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    30

    The Z coordinate refers to the aiming point to which the floodlight will be aiming at. In this case the aiming point was left at zero as the floodlight is to be mounted at 10 metres above the ground aiming down at the ground, for example to light a walkway. Chalmlite for Windows Z coordinate window opens

    o Enter the aiming point

    You can now determine to which angle the aim of the floodlight, by clicking on the target grid. Left click on the Target Grid to determine the aiming angle of the luminaire

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    31

    Left click to confirm all the aiming points on the target grid for the luminaire Right click to complete positioning the aiming points Right click once more to complete this process

    Shown above as are the two aiming angles created in an earlier procedure

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    32

    Luminaire Control & Zoom

    The Target Grid above shows lux levels in this project lux is the term used for the level of light distributed The minimum lux value are shown in cyan The maximum lux value are shown in red

    Selecting the Turn luminaire range off button, You will notice the values change automatically as the

    luminaires are turned off

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    33

    As shown above by You selecting the Turn luminaire range off button, the lux values have reduced greatly

    as shown by the increase of cyan points on the target grid

    Selecting the Turn luminaire range on button, You will be able to alter the lux levels once again by

    individually selecting a luminaire.

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    34

    Left click the appropriate luminaire you wish to turn back on

    By individually selecting one of the luminaires to be turned back on again You has altered the lux levels

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    35

    Selecting the Turn one floodlight off button, You will be able to alter the lux levels automatically

    Left click one of the aiming points from the floodlight to reduce the lux levels

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    36

    You can easily zoom in and out of any particular area on the grid by using the mouse wheel, alternatively You

    can use the view menu from the toolbar Select View menu from the toolbar

    o Zoom Window

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    37

    Define the screen Left click on the lower left hand corner of the screen

    Define the screen Left click again on the upper right hand corner to define the screen

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    38

    The screen definition is shown here in a green outline

    Shown here is the area defined in the previous step

    o The 10 signifies the mounting height of the luminaire, this is not part of the Target Grid

  • Chalmlite V4.04 : Getting Started Exterior Tutorial

    Chalmit Lighting March 2010 Revision 2

    39

    Select the View menu from the toolbar

    o Select Zoom Previous to return to the original screen view , with the complete target grid visible

    You has now completed the Exterior lighting design scheme section of this tutorial.

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting January 2009 Revision 1

    40

    My First Room

    You can create a new project by clicking the Projects button.

    Opening an existing project.

    o File o Open

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    41

    Load Data window opens

    o Select your chosen project

    Select Setup menu from the toolbar to modify your project settings

    o Setup o Project Settings

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    42

    New Project Settings - You must rename the project and choose the file directory to save this project to.

    o Enter new FILENAME o Enter new PROJECT NAME (if applicable) o Enter new SITENAME (if applicable) o Enter new ENGINEER (if applicable)

    The program offers two methods for defining rooms. This tutorial will demonstrate both.

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    43

    Select Interior menu from the toolbar to define the Interior Parameters

    o Interior o Define Room

    Define/edit room window opens

    o Simple, rectangular rooms can be quickly defined using the Rectangular room option o Edit the default lengths 1,3 and 2,4 as necessary o Edit room name to suit o The program automatically created a horizontal Target Grid in the room. The grid spacing (x and y)

    and grid height can be edited to suit o Edit the ceiling height as necessary

    3.0

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    44

    Define/edit room window

    Its important to click on the other length field after editing a length, otherwise the change will not hold. o Edit length, o Left-click on the other length field, otherwise the change will not hold.

    Define/edit room window

    o Edit the default reflectance value of the ceiling, wall and floor to suit. If desired, a vertical grid can be placed on the wall by checking the appropriate Grid box.

    o When all necessary edits are complete, click OK

    3.0

    Office

    3.0

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    45

    Position Room

    o Click Yes, the program will position the bottom-left corner of the room at (0,0) o Click No, the use can manually position the program of the bottom left corner of the room to suit.

    Position Room

    o Click Yes, the program will position the bottom-left corner of the room at (0,0) o Click No, the use can manually position the program of the bottom left corner of the room to suit. o Left-click where you wish to position the bottom-left corner of the room o The program will prompt you to Specify (x, y) location for luminaire(s) o If you do not wish to proceed to locate luminaires in the room at this point, simply right-click to finish

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    46

    After the room is positioned, the lux levels on the exterior Target Grid (Grid 1) are recalculated.

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    47

    Lighting the room & Reflections

    Define a luminaire using the programs Icon method

    Select Luminaires menu from the toolbar

    o Icon method o Define luminaire

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    48

    Define current luminaire icon window opens

    o You can click the icon to be used to signify the luminaire.

    Define current luminaire icon window

    o Click on preferred icon o Click Choose luminaire button

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    49

    Select Luminaire window opens

    o You can select the correct category to choose their luminaire o Click OK to continue

    Select Luminaire window

    o You can determine in the illustration above the degree of safety required for the project to be created o Click OK to continue

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    50

    Select Luminaire window

    o You can determine the luminaire type to be used in the project. o Click OK to continue

    Select Luminaire window

    o You can now choose the product model within the Fluorescent range to be used in the project. o Click OK to continue

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    51

    Select Luminaire window

    o You can now choose the product specification within the Fluorescent range to be used in the project. o Click OK to continue

    Define current luminaire icon window opens

    o Click Edit current description

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    52

    Define current luminaire icon window

    o Set luminaire parameters window opens Here You can determine the mounting height, tilt, etc

    o Click OK to continue

    Define current luminaire icon window

    o Edit the Icon scale factor to illustrate a more accurate scale on screen o Click OK to save and close this window

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    53

    Sometimes it is a good idea to zoom in closer in the room before beginning to locate the current luminare.

    Select View menu from the toolbar

    o Zoom Window Follow the program prompts in the lower-left bar of the screen to click the first, then second corners of the zoom

    window.

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    54

    Use the shortcut button on the toolbar to Locate luminare(s)

    Right click to complete locating luminaires Before turning on the room reflectance calculations, it is sometimes best to disable any external Target Grids in

    order to speed up the calculation process

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    55

    Click the Show/hide grid statistics window to open

    o This displays Target Grids in the project and their lux level statistics

    Uncheck the Vis (visible) box to disable a Target Grid

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    56

    Before turning on the room reflectance calculations, note the statistics of the grid in the room (Grid 2)

    o Click the Show/hide grid statistics window button to hide the window

    Select Room calcs menu from the toolbar

    o Select Medium

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    57

    Select Show/hide grid statistics window button to view how the lux level statistics in the room have changed

    o Click the button again to hide the Grid Details window

    With every change made, such a moving a luminaire to another location, the program will automatically

    recalculate the lux levels. Therefore, it is good practice to turn the room reflectance calculations off until needed.

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    58

    Select Room calcs menu from the toolbar

    o Select Off

    For basic rectangular rooms, the Interior Estimator feature can be used to quickly determine luminaire quantities

    for a given average lux level. To access this feature when in a Project, click on the Launch Interior Estimator shortcut button. Alternatively,

    select the Help menu and click Show front screen.

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    59

    Predefined room shapes

    Standard room shapes can be also be defined, i.e. L-shaped, C-shaped and T-shaped. The default length of

    each side of the shape can be edited.

    Select View menu from the toolbar

    o Zoom All

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    60

    Select Interior menu from the toolbar

    o Define room

    Select Standard shaped room button Choose a pre-defined room shape

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    61

    Choose C-shaped (missing on E side) and edit the lengths of sides 4 and 6

    You should change the Room name to suit If no edits have been made and the default settings are suitable, click OK to exit the Define/edit room window

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    62

    Position room

    o To join the bottom-left corner of the new room on to a corner of the existing room, click Yes.

    Left click near to the appropriate corner of the existing room.

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    63

    Right-click to complete positioning the room.

    Drawing rooms & Ceilings

    There is a second method to define a room. The Draw room method allows you to manually draw basic room shapes by left clicking on the screen to locate the corners of the room. Select Interior menu from the toolbar

    o Draw room.

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    64

    Left click to locate the first corner of your room

    Define/edit room window opens

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    65

    Define/edit room window

    o Select the Ceiling is non-flat radio button o Click the Edit ceiling profile button to edit

    Edit Ceiling window opens

    o The profile of a roof/ceiling can be adjusted. A single apex, three points are required o The direction of the apex can be set parallel to the x-axis (east-west) or the y-axis (north south)

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    66

    Edit Ceiling window

    o The height (Z value) of the three points can be adjusted to suit o Click OK when satisfied with the settings.

    Click OK to leave the Define/edit room window

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    67

    The direction of the apex is shown parallel to the x-axis as desired.

    Select Interior menu from the toolbar

    o Edit room o Move room

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    68

    Select room to edit window opens Select the room you wish to move and click OK

    Left click to position the bottom-left corner of the room

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    69

    Emergency Luminaires

    Emergency luminaires, i.e. with internal battery back-up, can be defined and quickly switched between emergency and mains mode operation by using shortcut buttons. Select Luminaires menu from the toolbar

    o Icon method o Define luminaire

    Select a different icon from that used for the normal (non-emergency) luminaire

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    70

    Define current luminaire window opens

    o You can click the icon to be used to signify the luminaire.

    Select Luminaire window opens

    o You can select the correct category to choose their luminaire o Click OK to continue

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    71

    Select Luminaire window

    o You can determine in the illustration above the degree of safety required for the project to be created o Click OK to continue

    Select Luminaire window

    o You can determine the luminaire type to be used in the project. All Emergency luminaires are stored within the Emergency category.

    o Click OK to continue

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    72

    Select Luminaire window opens

    o You can now choose the product model within the Fluorescent range to be used in the project. o Click OK to continue

    Select Luminaire window opens

    o You can now choose the product specification within the Fluorescent range to be used in the project. o Click OK to continue

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    73

    Define current luminaire icon window opens

    o Click Edit current description if the default height, maintenance factor, etc need to be changed. o Click OK to leave the Define current luminaire icon window.

    Important note when an emergency luminaire is defined, it is operating in emergency mode.

    Now that an emergency luminaire is defined, some of the previously located normal (non-emergency)

    luminaires can be changed to emergency versions.

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    74

    Select Luminaires menu from the toolbar

    o Select Icon method o Select Change one luminaire menu item

    Define current luminaire icon window opens

    o Ensure that the icon defined as emergency luminiare is highlighted o Click OK to continue

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    75

    Any number of luminaire icons can be changed by left clicking on each.

    Right-click to finish changing luminaire icons

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    76

    To view the lux levels achieved from the emergency luminaires only, the normal luminaire can be turned off.

    Click the Turn luminaire range off button.

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    77

    Click on any one of the normal (non-emergency) luminaire icons to turn off the range.

    To view a summary of the emergency lux levels

    o Click the Show/hide grid statistics window button.

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    78

    The Grid Details window displays a summary of the lux levels for each Target Grid i.e. minimum, average,

    uniformity (min/ave) and maximum. o Click the button again to close the window.

    To view the lux levels achieved with the normal luminaires turned on and the emergency luminaires turned to

    mains mode operation, the buttons on the right side of the screen are used.

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    79

    Click the Turn luminaire range on button and left-click on any one of the normal (non-emergency luminaire

    icons.

    Click the Turn luminaire range on to mains mode button.

  • Chalmlite V4.04 : Getting Started Interior Tutorial

    Chalmit Lighting March 2010 Revision 2

    80

    Left-click on any one of the emergency luminaire icons to turn the range to mains mode operation. The colour

    of the icons will change.

    You has now completed the Interior lighting design scheme section of this tutorial.