Page 1: Chromeleon 6.80 SR7 - Release Notes

. . . . . .. . .

Dionex Corporation

Dionex Corporation 2009-04 Page 1 of 17

1228 Titan Way

P.O. Box 3603

Sunnyvale, CA 94088-3603

. . . . . . . . . .

Product Release Notes for CHROMELEON

® Release 6.80 SR7

April 2009

Page 2: Chromeleon 6.80 SR7 - Release Notes

Release Notes Chromeleon 6.80 SR7

Dionex Corporation 2009-04 Page 2 of 17

Table of Contents

1 OVERVIEW AND SCOPE .........................................................................................................3 1.1 OVERVIEW .........................................................................................................................3 1.2 SCOPE ...............................................................................................................................3

2 WHAT'S NEW IN CHROMELEON 6.80 SR7............................................................................4 2.1 DIONEX INSTRUMENTS ........................................................................................................4

2.1.1 UltiMate 3000 SD/RS Pumps – New Drivers ......................................................4 2.1.2 Diagnostics Test for Dionex UltiMate 3000 RS/SD Pumps.................................4 2.1.3 AS-DV – New Driver............................................................................................4 2.1.4 ICS-1100, ICS-1600 and ICS-2100 - New Drivers..............................................4 2.1.5 RFIC-ER Concentrator Volume accommodation ................................................5 2.1.6 UltiMate 3000 Series DAD/MWD-3000(RS) – DAC Support ..............................5 2.1.7 WPS-3000TFC – Changed License Requirements ............................................5

2.2 THIRD-PARTY INSTRUMENTS ...............................................................................................5 2.2.1 Agilent HPLC 1200 System – Updated Driver ....................................................5 2.2.2 Agilent 7890A GC – Updated driver....................................................................5 2.2.3 Isco Foxy Fraction Collectors – Updated driver ..................................................6 2.2.4 Shimadzu LC-20A (Prominence) HPLC System – Updated driver .....................6 2.2.5 Waters Acquity UPLC – Updated Driver .............................................................6

2.3 IQ / OQ / PQ......................................................................................................................6 2.3.1 HPLC OQ/PQ – Version 6.9................................................................................6 2.3.2 HPLC Instruments IQ Version 2.1.......................................................................6

2.4 RESOLVED ISSUES..............................................................................................................7 2.5 DOCUMENTATION/ONLINE HELP ..........................................................................................8 2.6 CONTENT OF THE DVD .......................................................................................................8

3 INSTALLATION.........................................................................................................................9 3.1 COMPATIBILITY / REQUIREMENTS.........................................................................................9

3.1.1 Backward and Forward Compatibility..................................................................9 3.1.2 PC Requirements ............................................................................................. 10 3.1.3 Operating System Requirements ..................................................................... 10 3.1.4 Database Support ............................................................................................ 11 3.1.5 Required Third Party Software......................................................................... 12 3.1.6 Firmware Requirements ................................................................................... 13

3.2 GENERAL INSTRUCTIONS ................................................................................................. 13 3.3 “DIONEX TEMPLATES” DIRECTORY .................................................................................... 15 3.4 FIREWALL EXEMPTIONS NEEDED IN WINDOWS XP SP2 AND SP3 ...................................... 15 3.5 TROUBLESHOOTING ......................................................................................................... 15

4 APPENDIX.............................................................................................................................. 16 4.1 GENERAL INFORMATION ABOUT SERVICE RELEASES, RELEASE NOTES, AND ONLINE HELP . 16

4.1.1 Service Releases ............................................................................................. 16 4.1.2 Release Notes.................................................................................................. 16 4.1.3 Online Help....................................................................................................... 16

4.2 ABBREVIATIONS............................................................................................................... 16

Page 3: Chromeleon 6.80 SR7 - Release Notes

Release Notes Chromeleon 6.80 SR7

Dionex Corporation 2009-04 Page 3 of 17

1 Overview and Scope

1.1 Overview

CHROMELEON® Release 6.80 is a full-featured chromatography management system. Chromeleon can be ordered with full control of Dionex ICS and DX series ICs, INTEGRAL™ process analyzer, BioLC instruments, UltiMate™ and Summit™ HPLCs, and UltiMate™ Capillary and Nano LC systems.

Many third-party instruments and devices can be bi-directionally controlled through Chromeleon. This includes the Agilent 5890, 6850/6890, and 7890 GCs, 1100 and 1200 HPLCs; Perkin Elmer and Varian GCs, Waters Acquity UPLC, Alliance, 996 PDA, and 2487 detector, Shimadzu LC2010, GC-2010/2014, Merck Hitachi LaChrom, and the Surveyor Plus and TSP series LC equipment from Thermo.

Chromeleon features include processing and reporting of results from chromatograms, UV and MS spectra. Users who require operation under GLP and GMP rules will find comprehensive IQ/OQ/PQ procedures including System Suitability Testing, fully featured audit trails, detailed user management including electronic signature handling based on the provisions of 21 CFR Part 11.

Please refer to the Chromeleon User’s Guide and Online Help for specific operation and theory on the Chromeleon Chromatography Management System.

Tip The latest version of the English Chromeleon Online Help is available on the Service Release DVD (file “Additional Documents\Chromeleon 6.80 SR7 - Online Help.CHM”). Thus, the latest Help can be studied without first installing the Service Release.

1.2 Scope

The 6.80 SR7 Service Release DVD contains a full installation of the Chromeleon software, therefore, no previous Chromeleon installation is required. Also, refer to section 4.1.

Tip For information on installing Chromeleon on computers with Windows Vista, refer to “Additional Documents\Chromeleon and Windows Vista - 2008-12.pdf”.

The Service Release is cumulative. It contains all the new or enhanced features and the resolved issues of every previous CM 6.80 Service Pack and Driver Update (SP0a, SP1, SP1a, SP1b, SP2, SP2a, SP2b, SP2c, SP3, SP4, SR5, and SR6).

The Release Notes describe only the differences compared to the previous service release, i.e., compared to CM 6.80 SR6

For more information about the features introduced and issues fixed by previous Service Packs/Service Releases, please refer to the respective Release Notes.

For more information about Service Releases, please refer to section 4.1.

Page 4: Chromeleon 6.80 SR7 - Release Notes

Release Notes Chromeleon 6.80 SR7

Dionex Corporation 2009-04 Page 4 of 17

2 What's New in Chromeleon 6.80 SR7

2.1 Dionex Instruments

2.1.1 UltiMate 3000 SD/RS Pumps – New Drivers

This Service Release introduces support for the new UltiMate 3000 pumps for high-performance liquid chromatography (HPLC) and ultra-high performance chromatography (U-HPLC).

The following pump drivers are available:

Pump Type Pressure

ISO-3100SD analytical up to 50 MPa

LPG-3400SD analytical up to 50 MPa

DGP-3600SD analytical, two pumps in one enclosure; supports timebase sharing

up to 50 MPa

HPG-3200SD analytical up to 50 MPa

HPG-3400SD analytical up to 50 MPa

LPG-3400RS analytical up to 80 MPa

DGP-3600RS analytical, two pumps in one enclosure; supports timebase sharing

up to 80 MPa

The UltiMate 3000RS pumps also provide an additional input port for support of a manual injection valve.

2.1.2 Diagnostics Test for Dionex UltiMate 3000 RS/SD Pumps

Chromeleon supports the following Diagnostic tests for the pumps.

General Leak Test

Detailed Leak Test

Performance Test

Mixer Frit Test

Degasser Vacuum Test

2.1.3 AS-DV – New Driver

This Service Release provides support for the new autosampler, the AS-DV.

2.1.4 ICS-1100, ICS-1600 and ICS-2100 - New Drivers

This Service Release provides support for the new integrated systems, the ICS-1100, ICS-1600, and the ICS-2100. These instruments include standard and optional enhancements such as Reagent-Free operation, electrolytic sample preparation, and additional valve control.

Page 5: Chromeleon 6.80 SR7 - Release Notes

Release Notes Chromeleon 6.80 SR7

Dionex Corporation 2009-04 Page 5 of 17

2.1.5 RFIC-ER Concentrator Volume accommodation

This Service Release provides support to adjust for concentrator volumes in RFIC-ER operation for the following:

ICS-1000, ICS-1100, ICS-1500, ICS-1600, ICS-2000, ICS-2100, and the ICS-3000 DC.

2.1.6 UltiMate 3000 Series DAD/MWD-3000(RS) – DAC Support

The MWD/DAD-3000(RS) drivers now support the DAC plug-in module. The module provides two analog outputs for connection of additional evaluation devices.

2.1.7 WPS-3000TFC – Changed License Requirements

A standard Fraction Collection license is now sufficient for controlling the WPS-3000TFC.

2.2 Third-Party Instruments

2.2.1 Agilent HPLC 1200 System – Updated Driver

Chromeleon now supports the following modules of the Agilent HPLC 1200 system:

- Variable Wavelength Detector 1314D/1314E

2.2.2 Agilent 7890A GC – Updated driver

The updated Agilent 7890A driver adds support for:

Timebase Sharing – Dual Operation Mode

The 7890A GC can be shared on two timebases allowing simultaneous injections from different sample positions (dual operation mode).

Flexible use of one injector on front and back inlet:

The 7683B injector can be used to perform batch runs alternately on the front and back inlet.

Programmable Temperature Vaporizer inlet (PTV)

Using the PTV inlet, multiple injections can be performed with the 7683B injector.

Valves

Chromeleon provides support for up to 8 valves. Supported valve types are:

Gas sampling valves (GSV), multi-position valves, switching valves, remote start valves, other valves.

NOTE: Currently, only generic support is provided for the gas sampling valve, and multi-position valve.

Timed Events

Programming of up to 500 timed events for performing valve switching (GSV, switching valve, or other valve) and controlling detectors, such as, changing the polarity of a Thermal Conductivity Detector (TCD).

Manual injections

Page 6: Chromeleon 6.80 SR7 - Release Notes

Release Notes Chromeleon 6.80 SR7

Dionex Corporation 2009-04 Page 6 of 17

2.2.3 Isco Foxy Fraction Collectors – Updated driver

Chromeleon now supports the Isco Foxy R1 Fraction Collector.

To control the Foxy R1, use the "Foxy Jr/Foxy R1 Fraction Collector" driver. For connection to the Chromeleon PC, a 9-pin modem cable (Dionex P/N 8914.0143) is required.

2.2.4 Shimadzu LC-20A (Prominence) HPLC System – Updated driver

Chromeleon now provides full support of the LC-20A Prominence HPLC System that is controlled by a CBM-20A or CBM-20Alite system controller.

To control the LC-20A, use the "LC-10A/LC-20A HPLC System" driver. The system can be connected via either LAN or RS-232.

2.2.5 Waters Acquity UPLC – Updated Driver

The updated Waters Acquity driver adds support for:

Tunable UV detector

Selection of the pressure unit for the pump pressure signal (bar, psi, kPa)

NOTE: The Waters Acquity UPLC System Instrument Driver Software version 1.40 must be installed on the PC before you can install the Waters Acquity UPLC System driver. The software is shipped with the instrument.

2.3 IQ / OQ / PQ

2.3.1 HPLC OQ/PQ – Version 6.9

HPLC OQ/PQ version 6.9 adds support for the new UltiMate 3000 SD/RS pumps.

For details please refer to the “HPLC OQ PQ v.6.9 - Release Notes” document in the “Additional Documents” folder of the Service Release DVD.

2.3.2 HPLC Instruments IQ Version 2.1

HPLC Instruments IQ version 2.1 adds support for the new UltiMate 3000 SD/RS pumps.

For details please refer to the “HPLC Instruments IQ V.2.1 - Release Notes.pdf” document in the “Additional Documents” folder of the Service Release DVD.

Page 7: Chromeleon 6.80 SR7 - Release Notes

Release Notes Chromeleon 6.80 SR7

Dionex Corporation 2009-04 Page 7 of 17

2.4 Resolved Issues

This chapter describes the issues that have been resolved with the release of Chromeleon 6.80 SR7.

The numbers in the first column refer to the Dionex tracking IDs.

ID Description / Resolution

10237 Suggested step setting incorrect in ECD_Total PGM wizard. The suggested settings are now correct.

17615 CM Client – AIA Export: When performing an AIA export, the autosampler position was located in the ordinate values set. It is now located in the global attributes section of the AIA file.

17353 Possible complications in switching ICS-2000 from dual EGC mode to single EGC mode. Configurations can now be changed without issues.

17863 PDA-3000 – Time scale of extracted signal from 3D data collected by the PDA-3000 does not match 2D UV channels. The time scales now match.

18345 AS Sampler preparation and sampler Initialization sections reversed in PGM wizard. These are now in the appropriate order.

18466 Peak Detection – Small peaks are not detected. Peak detection now also recognizes smaller peaks.

18475 Shimadzu GC 2010 – The current for the ECD could not be sent to the GC. This has been corrected.

18569 QNT Editor – MS Enable/Disable Background subtraction cannot be saved. The MS spectra settings on the MS dialog page of the QNT Editor are not saved.

18597 Suppressor over voltage error on DC not logged. The errors are now logged if they occur.

18605 Incorrect access violation with DC thermal control. This has been corrected.

18625 Varian 3800 GC – Incorrect values used for the ConstantFlow property. When the ConstantFlowMode property was set to ON and ConstantFlow was set to 0.7, for example, the set value was changed to a different value on the GC.

18630 Agilent HPLC 1100/1200 – Running the System Diagnostics Pressure test caused the driver to hang up. The System Diagnostics Pressure Test can now be completed.

18634 CM Client – Silent mode for PDF export does not work. The silent mode now works correctly.

18635 Calibration – Calibration type "Cubic". Calibration type Cubic in conjunction with disabled Auto Recalibrate function occasionally returned "result = n.a" instead of an amount. This has been corrected.

Page 8: Chromeleon 6.80 SR7 - Release Notes

Release Notes Chromeleon 6.80 SR7

Dionex Corporation 2009-04 Page 8 of 17

ID Description / Resolution

18649 Agilent 7890A – Data acquisition is behind system retention time. The error occurred when the DataCollectionRate was manually deleted from the method and then not set manually. Now the DataCollectionRate is set to a default value on CM Server start time.

18650 Agilent 1x00 – DAD Intensity and Dark CurrentTest. Due to numerical problems, the DAD Intensity and Dark CurrentTest did not work correctly over the entire wavelength range. The numerical ranges have now been adapted to the correct values.

18651 RI-101 – The RT reproducibility has been improved.

18660 CTC PAL – The numerical precision of nominal values has been increased.

18676 TCC-3x00RS – The firmware download of an incorrect firmware was not rejected by the driver. The driver now checks for the correct firmware version.

18687 Single temperature zone DC configuration not compatible with DC firmware upgrade, 2.1.0. This has been corrected.

2.5 Documentation/Online Help

The Online Help has been updated; it describes the new features in this Service Release.

2.6 Content of the DVD

The content of the DVD (files and folders) are briefly described in the “Readme.html” file on the DVD itself.

Page 9: Chromeleon 6.80 SR7 - Release Notes

Release Notes Chromeleon 6.80 SR7

Dionex Corporation 2009-04 Page 9 of 17

3 Installation

3.1 Compatibility / Requirements

Attention Systems with Mass Spectrometry support have special requirements. For a compatibility matrix of supported hardware, Xcalibur, Chromeleon, and Windows versions, please refer to the “MS Software Configurations…” document provided in the “Additional Documents” folder on the Service Release DVD.

3.1.1 Backward and Forward Compatibility

When developing new versions of Chromeleon, Dionex attempt to always maintain “backward compatibility”, i.e., any data created with previous Chromeleon versions are readable with the new version and all calculations provide identical results. However, in rare cases, software issues may be discovered, which, if fixed, affect backward compatibility.

Introduction of new features sometimes require that the data formats are changed. In these cases, data created with Chromeleon 6.80 might not be readable with previous versions. In other words, “forward compatibility” cannot be guaranteed – this is quite natural in software development.

Backward and forward compatibility issues known in this Service Release are summarized in the following sections.

3.1.1.1 Backward Compatibility Issues

There are no changes in this Service Release that affect backward compatibility.

3.1.1.2 Forward Compatibility Issues

Dionex RS detectors (supported since 6.80 SR6) use a new data format that can be read only by Chromeleon versions 6.80 SR6 or later.

The Agilent 7890A GC driver uses a new Server Configuration format that can be read only by Chromeleon versions 6.80 SR7 or later.

Page 10: Chromeleon 6.80 SR7 - Release Notes

Release Notes Chromeleon 6.80 SR7

Dionex Corporation 2009-04 Page 10 of 17

3.1.2 PC Requirements

The table below shows the minimum and the recommended PC configuration for Chromeleon 6.80 SR7. The table is updated compared to the 6.80 Main Release to reflect increased requirements by Windows Vista and the new UltiMate 3000 Rapid Separation (RS) modules.

System Windows 2000 or XP

with NO UltiMate 3000 RSLC modules

Windows Vista SP1

with NO DAD-3000RS

Windows 2000 or XP

with ONE DAD-3000RS

Any supported OS

with TWO DAD-3000RS

Processor Pentium III class,

800 MHz minimum, 2 GHz recommended

Pentium 4 class,

2 GHz minimum

Pentium 4 class

2.4 GHz minimum

Dual Core processor

2 GHz minimum

RAM 256 MB minimum, 512 MB recommended

512 MB is the minimum requirement for systems with mass spectrometer, diode array or 3D amperometry detectors

1 GB minimum 512 MB minimum 1 GB minimum

Hard Disk 20 GB minimum

40 GB is the minimum requirement for systems with mass spectrometer, diode array or 3D amperometry detectors

60 GB minimum 100 GB minimum

Optical Drive DVD-ROM drive

Video Display 1024 x 768 resolution with 256 colors minimum, 16-bit color or more recommended

Ports At least one available USB port for license device (unless a License Server is used)

Further USB ports are necessary for connecting UltiMate 3000, Summit, and ICS devices

The following UltiMate 3000 detectors require USB 2.0 speed: MWD-3000(RS), DAD-3000(RS)

Expansion Slots

One PCI* slot for each DX-LAN™, RS-232 or GPIB card**

* Or one PCMCIA slot for notebook or Tablet PCs

** Please check with your Dionex representative to determine which expansion cards you require.

3.1.3 Operating System Requirements

Chromeleon is not compatible with 64-bit versions of Windows.

About virtualization (running Chromeleon on virtual machines):

o Virtualization techniques are usually not fully compatible with real-time operations and usage of multiple communication ports, which are essential for instrument control. For this reason, the Chromeleon Server cannot (reliably) run on virtual machines. Communication with the instruments may not be established at all, or communication problems are likely to occur.

o The Chromeleon Client usually works in virtual machines; however, this is not validated by Dionex.

3.1.3.1 Microsoft® Windows® 2000™

CM 6.80 SR7 will NOT install on SP2 of Windows 2000.

Windows 2000 SP3 is still accepted, but the Chromeleon Setup and IQ will issue a Warning.

Page 11: Chromeleon 6.80 SR7 - Release Notes

Release Notes Chromeleon 6.80 SR7

Dionex Corporation 2009-04 Page 11 of 17

As with the main Chromeleon 6.80 release, Dionex recommends SP4 for customers who must still use Windows 2000. NOTE: When the Chromeleon Transaction Agent is activated, special privilege settings must be applied under Windows 2000 SP4 (see section 4.4 in the Release Notes for the Chromeleon 6.80 main release).

3.1.3.2 Microsoft® Windows® XP

For the main Chromeleon 6.80 release, SP2 of Windows XP was recommended.

Since SP4, Chromeleon 6.80 also supports Windows XP SP3. NOTE: Some functions of Chromeleon may require changes in the firewall settings of Windows XP SP2 / SP3. For details, see section 3.4.

Windows XP (no SP) and SP1 are still accepted, but the Chromeleon Setup and IQ will issue a Warning.

3.1.3.3 Microsoft® Windows Vista®

With some limitations, starting with version 6.80 SP3, Chromeleon is compatible with Windows Vista. Dionex recommends using SP1 of Windows Vista. SP1 is required for controlling more than one system via USB. For more information, please refer to the “Chromeleon and Windows Vista” document in the “Additional Documents” folder on the SR DVD.

3.1.3.4 Microsoft® Windows® 2003 Server

For the main Chromeleon 6.80 release, SP1 of Windows 2003 Server was recommended.

Since CM 6.80 SP2, Chromeleon also supports Windows 2003 Server SP2.

3.1.4 Database Support

3.1.4.1 Required MDAC Versions

Chromeleon requires specific database interfaces that are provided with the Microsoft Data Access Components (MDAC). The validated versions are:

Operating System MDAC Version

Windows 2000 SP4 2.5 SP3

Windows XP SP2 2.8 SP1

Windows Server 2003 SP1 2.8 SP2*

Windows Vista MDAC is part of the Operating System

* Special version included with Windows Server 2003 SP1

Note The MDAC check for CM 6.80 includes all MDAC versions from 2.5 (RTM - SP3), 2.6 (RTM - SP2), 2.7 (RTM - SP1) and MDAC 2.8 (RTM and SP1). Future MDAC versions may not be recognized correctly. If in doubt, check for the newest version of Microsoft's 'Component Checker' tool on the Microsoft homepage. A version of this tool is also available on the DVD: Other Tools\ODBC\Component_Check.exe.

Page 12: Chromeleon 6.80 SR7 - Release Notes

Release Notes Chromeleon 6.80 SR7

Dionex Corporation 2009-04 Page 12 of 17

3.1.4.2 Supported Oracle Versions

Chromeleon has been validated to work with Oracle 8i, version 8.1.7, Oracle 9i, version 9.0.1.1.1, and Oracle 10g Release 2.

The connection to an Oracle database server requires the “Microsoft ODBC driver for Oracle”, which is part of the MDAC package. This is the only validated ODBC driver for the connection to Oracle databases.

Caution The Oracle-provided driver for ODBC will not work with Chromeleon.

3.1.4.3 Supported Microsoft SQL Server Versions

Chromeleon has been validated to work with Microsoft SQL Server 2000, version 8.00.382 and 2005, version 9.00.1399.00.

The connection to Microsoft SQL Server 2000 requires the Microsoft SQL Server driver. The connection between Chromeleon and the database was validated with this driver.

Caution Do not use any other driver to connect to a Microsoft SQL Server database.

3.1.5 Required Third Party Software

3.1.5.1 Microsoft .NET Framework

Chromeleon 6.80 requires the Microsoft .NET Framework, Version 2.0 SP2 (applies to all supported Windows operating systems except Windows Vista).

If not already present on the target computer, the necessary files are installed automatically during the installation of Chromeleon. In this case, the installation events are logged in a file called DotNetInstall20.log in the \Chromel\IQ folder.

Note: To enable automatic installation, Windows Installer 3.1 must be installed first (contained on the Service Release DVD in folder "Other Tools / WindowsInstaller").

CM IQ has been updated and checks whether .NET is properly installed. If it is not, an Error is issued.

On computers with Windows Vista, Microsoft.NET Framework, Version 3.5 SP1 is required. For details, please refer to the "Readme.html” file on the DVD itself.

3.1.5.2 Microsoft MSXML

Chromeleon 6.80 requires the Microsoft MSXML Version 4 SP2.

The necessary files are automatically installed during the installation if they are not already present on the target computer. In this case, the installation events are logged in a file called msxmlsetup.log in the \Chromel\IQ folder.

CM IQ has been updated and checks whether MSXML is properly installed. If it is not, an Error is issued.

Page 13: Chromeleon 6.80 SR7 - Release Notes

Release Notes Chromeleon 6.80 SR7

Dionex Corporation 2009-04 Page 13 of 17

3.1.6 Firmware Requirements

3.1.6.1 Dionex IC instruments

To ensure proper operation, Dionex IC instruments should be equipped with the most recent firmware. A table of validated firmware versions is provided in the “IC Firmware Validation Matrix…” document in the “Additional Documents” folder on the SR DVD. If you have instruments with firmware versions older than those listed, please contact your local Dionex office for assistance.

3.1.6.2 Other Dionex instruments

For other Dionex instruments, such as the UltiMate 3000 and Summit modules, the recommended firmware versions are included in Chromeleon. You can check the version and update the firmware from within the CM Server Configuration. Whenever a new firmware version is released for these modules, this is described in the corresponding Chromeleon Release Notes. For information about new firmware versions provided with this Service Release, please refer to section 4.1.

3.1.6.3 Third-party instruments

For third-party instruments, the Online Help describes the tested / minimum required firmware versions. Using an older firmware may cause communication problems. Dionex does not expect any problems to occur with using newer firmware versions. For systems like the Agilent 1100 and 1200, all modules must have the same/compatible firmware version.

3.2 General Instructions

Attention Make sure that the installation operator has full local Windows administrator privileges. During the installation, the PC must be restarted. After this, the same operator must log in again, so that the remaining steps of the installation process can be performed correctly. Otherwise, the installation will fail or will be incomplete!

Attention For installation on terminal servers, remember to activate "Install mode”!

Tip The Service Release is cumulative, i.e., it contains all the previous Service Release, Service Packs, and Driver Updates of Chromeleon 6.80. Therefore, it is not necessary to install any Service Release/Pack or Driver Update prior to installing this Service Release. For more information about Service Packs, Service Releases and Driver Updates, see section 4.1.

To install this Service Release, exit all Chromeleon programs (including the CM Server and CM Server Monitor) and run either one of the following programs:

Chromeleon_Service_Packs_April_2009.exe

Chromeleon Service Pack Master Setup, which detects your Chromeleon version and launches the appropriate setup program for releases 6.60, 6.70, or 6.80.

Page 14: Chromeleon 6.80 SR7 - Release Notes

Release Notes Chromeleon 6.80 SR7

Dionex Corporation 2009-04 Page 14 of 17

Setup.exe Chromeleon 6.80 Service Release 7 (in subfolder CM680SR7)

If the master setup does not recognize your installed version or refuses to install, use the individual setup package that is labeled with your Chromeleon release, i.e., Setup.exe.

The 6.80 SR7 Service Release DVD contains a full installation of the Chromeleon software, therefore, no previous Chromeleon installation is required.

Tip For information on installing Chromeleon on computers with Windows Vista, refer to “Additional Documents\ Chromeleon and Windows Vista - 2008-12.pdf”.

Updated versions of various administrative programs are available in separate directories on the Service Release DVD:

CMSSR Chromeleon System Status Report (SSR) Utility

This troubleshooting tool was introduced with Chromeleon 6.80, and is now available also for Chromeleon 6.70 and 6.60.

If an error occurs during operation of Chromeleon, you can use the SSR to create an error report that includes detailed information about Timebases, Datasources, installations, and the system.

All users of Chromeleon 6.60 and 6.70 should install this tool. Chromeleon 6.80 users need not (and should not) install it, because Chromeleon 6.80 already includes the System Status Report utility.

CmUser680SR5 Chromeleon User Manager 6.80 SR5

This version is compatible with all current and previous releases of Chromeleon.

CMLS680SP0 License Server 6.80 SP0

This tool is only used in (larger) installations where the Chromeleon licenses are provided from a license server to the PCs with Chromeleon (i.e., it is used instead of dongles).

Note The Chromeleon IP Utility is no longer included on the Service Release DVD. This tool was used for a few modules (UI20, UVD, P680, early TCC) by users who wished to use Ethernet connections instead of USB. The utility is still available on the Chromeleon 6.80 (Main Release) CD, or by request from Dionex Technical Support.

Page 15: Chromeleon 6.80 SR7 - Release Notes

Release Notes Chromeleon 6.80 SR7

Dionex Corporation 2009-04 Page 15 of 17

3.3 “Dionex Templates” directory

The setup will create a locked folder named “Dionex Templates” on the home Datasource of the system. Typically, this Datasource is named <PC_name>_local. The template folder contains directories for Chromeleon IC Application Templates, Panels, and Reports. The Panels directory is grouped according to the target devices, such as, Dionex_IC, Dionex_LC, GC, LC_MS, etc. These panels serve as masters to adapt and create new panels for the installation.

Attention To avoid problems, keep the “Dionex Templates” folder locked. - Do not delete or move any items from the “Dionex Templates” directory. - Do not modify files in the “Dionex Templates” directory. Instead, copy the desired items to other directories and modify the copies. - Do not store any personal data (including panels or reports) in this directory, because they may be deleted without warning during future upgrades.

Note Previously, a copy of the “Dionex Templates” folder was available in the Datasource on the SP CD. This is not the case anymore. However, installing the Service Release will still update the content of the Dionex Templates folder on your local Datasource.

3.4 Firewall Exemptions Needed in Windows XP SP2 and SP3

With Service Pack 2, Microsoft introduced a firewall in Windows XP. To operate Chromeleon with this firewall, a few exceptions must be defined in certain scenarios.

For details, please refer to topic "Chromeleon and Windows Firewall" in the Chromeleon Online Help.

3.5 Troubleshooting

The “Readme.html” file on the DVD contains a troubleshooting section describing a few known but rare installation issues.

Page 16: Chromeleon 6.80 SR7 - Release Notes

Release Notes Chromeleon 6.80 SR7

Dionex Corporation 2009-04 Page 16 of 17

4 Appendix

4.1 General Information about Service Releases, Release Notes, and Online Help

4.1.1 Service Releases

Service Releases (SR) contain the setup package with all the files of the Main Release plus the changed files of all previous service packs, service releases, and driver updates. Thus, with a Service Release, it is no longer necessary to install the Main Release first.

4.1.2 Release Notes

The Release Notes describe the new features and improvements of the latest Service Release only. For information on extensions and enhancements in previous Chromeleon releases, please refer to the Release Notes of the respective Chromeleon release.

4.1.3 Online Help

Note The Release Notes may contain last minute information that could not be captured in the Online Help or takes priority over the Online Help.

In general, new features and drivers that are introduced in Service Packs / Service Releases are described in the updated Online Help that is distributed with the Service Pack / Service Release. However, the Online Help is only updated for the latest Chromeleon version. Users of previous versions can find the latest version of the English Chromeleon Online Help on the Service Pack / Service Release DVD (file “Additional Documents\Chromeleon 6.80 SR7 - Online Help.CHM”).

4.2 Abbreviations

The following abbreviations are used throughout this document. Further explanations can be found in the chapters of use.

2D, 3D 2 dimension(al), 3 dimension(al)

CM (6.80) CHROMELEON® (Release 6.80)

CRD Carbonate Removal Device

DU Driver Update

DVD Digital Versatile Disc

DX Dionex

GC Gas Chromatograph(y)

HPLC High Performance Liquid Chromatograph(y); also synonymous with High Pressure Liquid Chromatograph(y)

IC Ion Chromatograph(y)

IQ Installation Qualification

LAN Local Area Network

LC Liquid Chromatograph(y)

Page 17: Chromeleon 6.80 SR7 - Release Notes

Release Notes Chromeleon 6.80 SR7

Dionex Corporation 2009-04 Page 17 of 17

MS Mass Spectrometry

n.a. Not Applicable

OQ Operational Qualification

OS Operating System

OTA Online Transfer Agent

PAN CHROMELEON Control Panel object

PDA Photo Diode Array

PDF Portable Document Format

PGM CHROMELEON Control Program object – instructions to a chromatographic system for an analytical run

PQ Performance Qualification

QNT CHROMELEON Quantitation method object

QRY CHROMELEON Query definition object

RDF CHROMELEON Report Definition File object – defines screen layout in integration view, defines report layout

RSLC Rapid Separation LC

SDK Software Development Kit

SEQ CHROMELEON Sequence object – defines a collection of samples

SOR CHROMELEON Signed Off Results object, or Solvent Organizer Rack (SOR-100)

SP Service Pack

SR Service Release

SQL Structured Query Language

SR Service Release

SST System Suitability Test

TCD Thermal Conductivity Detector

TSP Thermo Separation Products (Now Thermo)

UCI Universal Chromatography Interface – a Dionex product that allows virtually any chromatography device to be connected with CHROMELEON through different ports

USB Universal Serial Bus

[USER] Within a heading denotes a feature that was added based on users requirement / wish

WSP CHROMELEON Workspace object [#xxxxx] Specifies a Dionex Tracking ID