Clarity Chromatography Software

Clarity 3.0 – New features

Page 2: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

2

More than 100 new features in version 3.0

Calibration Import/ExportChromatogramEvent table

User Interface ReportsSequence

Page 3: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

3

Opening the Clarity Instrument

Select your Project during

the logon

Option to select project in Login DialogAuto Lock - option to lock Instrument after

predefined period

Page 4: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

4

Improvements in user interface

User Options - new tab Directories to set paths for PDF reports, exports and imports

Tables - function Fill series (Sequence, Calibration, Gradient)

Page 5: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

5

CalibrationBracketing, Standard Addition, Normalization Improved Identification Windows Forced Compound IdentificationNew Calibration curves, Linearization of

Calibration Graph AxesCalculation by Response of Another CompoundResponse factor as Amount/Response or

Response/AmountResponse Correction Factor

Page 6: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

6

Calibration Options

Calibration curve check

Failure displayed in the Peak Type

column in Result Table New Calculation

types

NORMSTDADD

Page 7: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

7

Linearization of axes in Calibration

Select appropriate function to

linearize the values on X, Y

axes

Show linearized values in

Graph Properties

Page 8: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

8

New Curve Fit Types in Calibration

Select a new curve:• ln• log10• exp• pow10• Hyperbola• Half Sigmoid

Page 9: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

9

ChromatogramUser columns – compound name in special values Mathematical operations – invert function to

reverse polarityAdvanced peak tags File open dialog – option to change overlay modeResult table – peak type indicates more infoSupport for electronic signatures in PDF reports

Page 10: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

10

Enhanced Peak Type info

Peak Type in Result Table indicates used calibration options

Ordnr/Ref/ISTD/RISTD/GRP peak typeError value could not be calculatedError (Curve Check) calibration curve does not met preset criteria<LOD and<LOQ value lower then set limits(Forced) identification forced by integration table(by name) another compound calibration data used(CF) correction factor in calibration applied

Page 11: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

11

Overlay mode

Change to Overlay mode in

Open Chromatogram

dialog

Page 12: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

12

Electronic signatures in PDF reports

Page 13: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

13

Force Peak Identification

Force Peak Identificati

onSelect Peak

to Force

Select new Peak

Identification

Name peaks without calibration file

Override identification by calibration

Page 14: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

14

Relative Retention Times

Force Peak Identificati

on

Calculated RRT

Setup User Column using

the Special Values,

Compound option

Page 15: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

15

Customizable order of Report Sections

Right click the tab and adjust its

position

Page 16: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

16

Export of graphsExport of graphs from PDA viewExport Calibration curve as picture

[g/kg]Amount0,0 0,5 1,0 1,5 2,0 2,5 3,0

[mV.s]

Resp

onse

0

50

100

150

Page 17: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

17

Export of data in Excel (.xls) format

Page 18: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

18

Import Chromatogram Data

Store your preferences

for future use(user specific)

Import of multiple signal

chromatogram data

aranged in columns

Preview the imported data

file

Preview the imported data

file

Apply same settings to

multiple files opened

simultaneously

Page 19: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

19

Event tableEvents could be performed outside runNew input conditionsNew output actionsResizable dialog and columns width

New set of event for

running/idle state of

Instrument

New set of commands in

Output

Page 20: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

20

Valve control Set custom

position for Valve at Close Instrument

Input/Output names instead of

numbers

Set custom position for Valve

at Close Instrument

Page 21: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

21

SequenceBypass to perform run without injection for

startup and shutdown methods

New file name variables

%P – Project%s – Sequence%J – Method

New columns:• Include in SST – perform SST

test when injection is finished

• Stored Calib. – chromatogram will be opened with stored calibration

• Close All – close all currently opened chromatograms in overlay to prepare for next summary report

Page 22: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

22

Bracketing and Standard Addition

Calibration and Sequence Usage

Clone calibration at each Sequence start

Standard AdditionBracketing

This calibration will be used with Calibration used as

specified by user

Copy of the Example Calibration will be created according to Sequence options,

Calibration and Sequence Usage

Page 23: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

23

Extension and Control ModulesPDA – option Add All Identified Peaks to

Spectrum library FC GP – new option Collect all Flow rate units options extended to L/min,

mL/min, µL/min

Page 24: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

24

Control Modules in development

Agilent 7890 GC Agilent 1200 HPLC DAD (G1315D)Sedere ELSD detector 80LT and

85LTPG Instruments LC-200 HPLC

Page 25: Clarity Chromatography Software

page: Date: 26.2.2010Code: P021/30A

25

For more information please visit our website:

What‘s new ( menu: Products – Clarity – Next steps – What is new)

Preliminary Demo version ( menu: Downloads – Preliminary versions)

Preliminary version ( menu: Downloads – Preliminary versions)