Clarity Chromatography Software

Clarity 3.0 – New features

Page 2: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

2

More than 100 new features in version 3.0

Calibration

Import/Export

Chromatogram

Event table

User Interface

Reports

Sequence

Page 3: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

3

Opening the Clarity Instrument

Select your Project during

the logon

Option to select project in Login Dialog

Auto Lock - option to lock Instrument after predefined period

Page 4: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

4

Improvements in user interface

User Options - new tab Directories to set paths for PDF reports, exports and imports

Tables - function Fill series

(Sequence, Calibration, Gradient)

Page 5: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

5

CalibrationBracketing, Standard Addition, Normalization

Improved Identification Windows

Forced Compound Identification

New Calibration curves, Linearization of Calibration Graph Axes

Calculation by Response of Another Compound

Response factor as Amount/Response or Response/Amount

Response Correction Factor

Page 6: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

6

Calibration Options

Calibration curve check

Failure displayed in the Peak Type

column in Result Table

New Calculation types

NORMSTDADD

Page 7: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

7

Linearization of axes in Calibration

Select appropriate function to

linearize the values on X, Y

axes

Show linearized values in

Graph Properties

Page 8: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

8

New Curve Fit Types in Calibration

Select a new curve:• ln• log10• exp• pow10• Hyperbola• Half Sigmoid

Page 9: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

9

ChromatogramUser columns – compound name in special values

Mathematical operations – invert function to reverse polarity

Advanced peak tags

File open dialog – option to change overlay mode

Result table – peak type indicates more info

Support for electronic signatures in PDF reports

Page 10: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

10

Enhanced Peak Type info

Peak Type in Result Table indicates used calibration options

Ordnr/Ref/ISTD/RISTD/GRP peak typeError value could not be calculatedError (Curve Check) calibration curve does not met preset criteria<LOD and<LOQ value lower then set limits(Forced) identification forced by integration table(by name) another compound calibration data used(CF) correction factor in calibration applied

Ordnr/Ref/ISTD/RISTD/GRP peak typeError value could not be calculatedError (Curve Check) calibration curve does not met preset criteria<LOD and<LOQ value lower then set limits(Forced) identification forced by integration table(by name) another compound calibration data used(CF) correction factor in calibration applied

Page 11: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

11

Overlay mode

Change to Overlay mode in

Open Chromatogram

dialog

Page 12: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

12

Electronic signatures in PDF reports

Page 13: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

13

Force Peak Identification

Force Peak Identificati

onSelect Peak

to Force

Select new Peak

Identification

Name peaks without calibration file

Override identification by calibration

Name peaks without calibration file

Override identification by calibration

Page 14: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

14

Relative Retention Times

Force Peak Identificati

on

Calculated RRT

Setup User Column using

the Special Values,

Compound option

Page 15: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

15

Customizable order of Report Sections

Right click the tab and adjust its

position

Page 16: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

16

Export of graphsExport of graphs from PDA view

Export Calibration curve as picture

[g/kg]Amount

0,0 0,5 1,0 1,5 2,0 2,5 3,0

[mV.s]

Res

pons

e

0

50

100

150

Page 17: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

17

Export of data in Excel (.xls) format

Page 18: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

18

Import Chromatogram Data

Store your preferences

for future use(user specific)

Import of multiple signal

chromatogram data

aranged in columns

Preview the imported data

file

Preview the imported data

file

Apply same settings to

multiple files opened

simultaneously

Page 19: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

19

Event tableEvents could be performed outside run

New input conditions

New output actions

Resizable dialog and columns width

New set of event for

running/idle state of

Instrument

New set of commands in

Output

Page 20: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

20

Valve control Set custom

position for Valve at Close Instrument

Input/Output names instead of

numbers

Set custom position for Valve

at Close Instrument

Page 21: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

21

SequenceBypass to perform run without injection for

startup and shutdown methods

New file name variables

%P – Project%s – Sequence%J – Method

New columns:• Include in SST – perform SST

test when injection is finished

• Stored Calib. – chromatogram will be opened with stored calibration

• Close All – close all currently opened chromatograms in overlay to prepare for next summary report

Page 22: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

22

Bracketing and Standard Addition

Calibration and Sequence Usage

Clone calibration at each Sequence start

Standard AdditionBracketing

This calibration will be used with Calibration used as

specified by user

Copy of the Example Calibration will be created according to Sequence options,

Calibration and Sequence Usage

Page 23: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

23

Extension and Control ModulesPDA – option Add All Identified Peaks to

Spectrum library

FC GP – new option Collect all

Flow rate units options extended to L/min, mL/min, µL/min

Page 24: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

24

Control Modules in development

Agilent 7890 GC

Agilent 1200 HPLC DAD (G1315D)

Sedere ELSD detector 80LT and 85LT

PG Instruments LC-200 HPLC

Page 25: Page:Date: 26.2.2010Code: P021/30A1 Clarity Chromatography Software Clarity 3.0 – New features

page: Date: 26.2.2010Code: P021/30A

25

For more information please visit our website:

What‘s new ( menu: Products – Clarity – Next steps – What is new)

Preliminary Demo version ( menu: Downloads – Preliminary versions)

Preliminary version ( menu: Downloads – Preliminary versions)