Cleveland Alliances 01361883418 Software rel. 2.3.x VOLUME COUNTER VERSION

Upload: others

Post on 12-Nov-2021

17 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

Software rel. 2.3.x

VOLUME COUNTER VERSION

Page 2: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

2

CONTENTS

● Legendofsymbols.....................................................................................................3INTRODUCTION ............................................................................................................4

Productdescription....................................................................................................4INTENDED USE .............................................................................................................4CONTENT OF THE PACKAGE .....................................................................................4PRECAUTIONS .............................................................................................................4RISKS AND PROTECTIONS BEFORE ASSEMBLY ....................................................5

Positioning..................................................................................................................5Powersupplyandsensorconnection........................................................................5

ASSEMBLY DIAGRAMS ...............................................................................................6CONTROLS IN THE MENU ...........................................................................................7

Firstswitchingon.......................................................................................................7Controlsinthemenu..................................................................................................8Workparameters........................................................................................................9

MENU STRUCTURE ....................................................................................................10PRELIMINARY SETUP FOR USE ............................................................................... 11

Flowratealarms........................................................................................................ 11Sensors....................................................................................................................12Flowmetercalibration...............................................................................................13Language.................................................................................................................15Unitsofmeasurement..............................................................................................16Displaycontrast........................................................................................................17Alarmtones..............................................................................................................18Keytones..................................................................................................................18Displaysettings........................................................................................................19Operatingmode.......................................................................................................20Setupmanagement..................................................................................................21Testmenu.................................................................................................................23

USE ..............................................................................................................................25Partialtotalizerreset................................................................................................25

MAINTENANCE / DIAGNOSTICS / REPAIRS ............................................................26Troubleshooting........................................................................................................26

END OF LIFE DISPOSAL ............................................................................................26TECHNICAL DATA ......................................................................................................27

Devicetechnicaldata...............................................................................................27Setupmenu..............................................................................................................28

GUARANTEE TERMS .................................................................................................29

Page 3: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

3

● Legendofsymbols

= Genericdanger

= Warning

This manual is an integral part of the equipment to which it refers and must accompany the equipment in case of sale or change of ownership. Keep it for any future reference; ARAG reserves the right to modify product specifications and instructions at any moment and without notice.

Page 4: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

4

INTRODUCTION

Productdescription

VISIOisaverycompactandaccuratetop-notchmultifunctiondisplay,abletodisplayanykindofinformationconcerningagriculturaltreatments.Operatorcanselecttherequiredfunctionviasoftware.Itcandisplayseveraltypesofvalues,whichchangeaccordingtosetoperatingmodeandtypeofconnectedsensors.

INTENDED USE

This device is designed towork onagriculturalmachinery for spraying and cropsprayingapplications.ThemachineisdesignedandbuiltincompliancewithENISO14982standard(Electromagneticcompatibility-Forestryandfarmingmachines),harmonizedwith2014/30/UEDirective.

CONTENT OF THE PACKAGE

ThetablebelowindicatesthecomponentsthatyouwillfindintheVISIOpackage:

Legend:

1 VISIO2 Fixingkit3 Instructionmanual (onCD-ROM)4 Installationsheet

PRECAUTIONS

•Donotaimwaterjetsattheequipment.•Donotusesolventsorfueltocleanthecaseoutersurface.•Donotcleanequipmentwithdirectwaterjets.•Complywiththespecifiedpowervoltage(12VDC).•Incaseofvoltaicarcwelding,removeconnectorsfromVISIOanddisconnectthepowercables.•OnlyuseARAGgenuinesparepartsandaccessories.

P o w e r c a b l e ,s e n s o r s a n dconnection cablesto be connectedto VISIO must beorderedseparately.

Page 5: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

5

RISKS AND PROTECTIONS BEFORE ASSEMBLY

Allinstallationworksmustbedonewithbatterydisconnected,usingsuitabletoolsandanyindividualprotectionequipmentdeemednecessary.

Positioning

1) Set mounting rail in cabin and fasten it with the relevant screws (1), in a position where VISIO can be easily seen and at hands' reach, but away from any moving organs.2) Secure VISIO to rail and push down until locked in place.3) Fasten wiring so that it does not interfere with any moving parts.

Powersupplyandsensorconnection

Sensorsandpowersupplymustbeinstalledandconnectedbyqualifiedpersonnel.VISIOmustbeexclusivelyconnectedtoARAGequipment.WHENARCWELDINGISREQUIRED,MAKESURETHATEQUIPMENTPOWER IS SWITCHED OFF; DISCONNECT POWER CABLES IF NEEDED.ARAGisnotliablefordamagetothesystem,persons,animalsorpropertycausedbyVISIOwrongorunsuitableassembly.Failuretoobservetheaboveinstructionsautomaticallyvoidsthewarranty.

Wirecolor (powercable) Connectionof

red positive

black negative

green countingabort-groundconnection

yellow countingabort-connection+12VDC

power supplysensors

Page 6: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

6

ASSEMBLY DIAGRAMS

Counting abortGround

connection(green wire)

Counting abortConnection

+12VDC

(yellow wire)

3

+12Vdc

GND

Legend:1)Powercable2)Connectioncableforsinglesensor3)Flowmeter

Page 7: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

7

CONTROLS IN THE MENU

Firstswitchingon

Atfirstswitchingon,VISIOwillrunaguidedprocedureallowingusertosetthedevice'sbasicsettings.

Press toscrollthroughitems,OKtosaveandmoveontonextsetting,orESCtogobacktoprevioussetting.

WARNING:Beforechangingoperatingmode,makesurethatallsensors/flowmetersareDISCONNECTEDfromthedevice.

Page 8: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

8

Controlsinthemenu

Inthefollowingpages,accordingtothesetoperatingmode,somemenuitemscouldslightlydifferfromtheshownones.

SWITCHING ONAPressfor1second;BPressthekeytoviewthevariousvaluesinextendedmode,inasequence(ondisplaycentralpart).Everytimethedeviceisswitchedon,itwillshortlyshowapagewiththenameofdeviceandsoftwareversion.

SWITCHING OFFAPressfor2seconds.

ACCESS TO SETUP MENUFromthemainpage,presskeysatthesametimefor2secondstoopentheSetupMenu.

SELECTION AND ACCESS TO MENU ITEMS

APressafewtimestoscrollthroughitems(selecteditemisindicatedbyablackline);BPresstoopentheselectedmenuitem.

Thethreedotsunderanitemindicatepresenceofanothersetupmenu.

Page 9: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

9

EDITING A VALUEAPresstomovethroughdigits;BPressafewtimestoeditthehighlighteddigit;CPresstoconfirm.Thedisplaygoesbacktopreviouspage;DPresstoexitpagewithoutconfirmingmodification.

Editedvaluemustfallwithintherangeshown.

Workparameters

l

2

1

0.0

l0.00

0.00

l/min

Fromthemainpage,presskeyfortwosecondstoopenWorkParametersmenu,andsetvaluesforFlowcorrection.

Page 10: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

10

MENU STRUCTURE

Page 11: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

11

PRELIMINARY SETUP FOR USE

Flowratealarms

Setminimumandmaximumflowratethresholdsforalarmmessage.

1)OpenAlarmmenu(Setupmenu>Alarms).

Minimumandmaximumflowratealarmsaresetinthesameway.

Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toedittheselectedmenuitem.

2)Toactivatethealarm,press and

atthesametimeuntilmessage OFF

goesoffandratealarmvalueisdisplayedinstead.Carryoutthesameproceduretodisablealarmagain.3)Setalarmvalue:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.

Page 12: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

12

Sensors

1)OpenSensorsmenu(Setupmenu>Sensors).

Themenuitemsdisplayedbelowchangeaccordingtothesetoperationmode:whenmoreitemsareavailable,selectthedesiredoneandpressOKtoeditit.

Page 13: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

13

Flowmetercalibration

Duetothedifferentsystemconfigurations(tubes,valves,etc.)ratereadingcouldnotbecorrect.Itisthereforerecommendedtoperformasprayingtest.Ifmeasuredvalueisdifferentfromactualvalue,changetherateconstantthroughanautomaticcalibrationprocedureormanuallycalculatetheconstant.

Automatic calibration

Letapreviouslymeasuredquantityoffluidgothroughthesystemoraquantitythatcouldbemeasuredthroughanothersystem.Thehigherthequantityoffluidusedtoperformthecalibrationprocedure,themoreaccuratethecalibration.

1)Openautomaticcalibrationmenu(Setupmenu>Sensors>Flowmeter>AutoCalibration).Assoonasmenuisopen,theequipmentisreadytostartmeasuringwithnofurthercontrolsbeingrequired.2)Startliquidflowinthesystem.Thedisplaywillstartshowingtheincreasingvalueofthemeasuredfluidquantity.Assoonasfluidflowisover,thedisplayedcounterwillstop.

3)NowpressOK.AtthebottomofthedisplayStabilization,messagewillturnonandequipmentwillthenshowthepageontheside.4)Enterpreviouslymeasuredquantityoffluid:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstocompletethecalibrationprocedure,orD)Pressfor1secondtocancelthecalibrationprocedure.

1 Setting the fluid quantity actually passed through flowmeter during the calibrationprocedure.2 Viewingthefluidquantityreadbyflowmeterduringthecalibrationprocedure.

Page 14: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

14

Ifequipmentdoesnotdetectanyflowaftercalibrationisstarted(anddisplayedvalueremains0),pressOKtoquitthecalibrationprocedurewithoutsaving.IfthedevicecontinuestodetectflowafterOKwaspressed,theerrormessageStop flow!.willbedisplayedafterafewseconds.Assoonasflowisstopped,readingwillstabilize,asperstandardprocedure.IncaseVISIOcalculatesavalueoutoftherangethatcanbesetbymeansofthemanualcalibration,thecalculatedvaluewillnotbeset.

Manual calibration

Inordertomanuallysetrateconstant,calculateandsetsuitableconstantusingthefollowingformula:

1)Openmanualcalibrationmenu(Setupmenu>Sensors>Flowmeter>Man.calibration).UnderCalibrationmenu,selectMan.calibration,toviewcurrentlysetconstantvaluebelowtheitem.PressOKtoeditthevalue.

Forflowmeterconstantvalue,refertothecorrespondingmanual.

2)Setflowmeterconstantvalue:A)Presstomovethroughdigits.B)Pressafewtimestoeditthehighlighteddigit.C)Presstosavechanges,orD)Presstoquitthepagewithoutconfirmingchanges.

[quantity measured by equipment]

[actually sprayed quantity]x [constant indicated on flowmeter body]

Page 15: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

15

Language

Setthedesiredlanguage.

Options

Language

English

Units of measurem.

Display contrast

Openlanguagesettingmenu(Setupmenu>Options>Language).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.

PressOK toeditlanguage.

2 1

2

Language

English

ČeskDeutsch

Español

1)Selectalanguagethrough .

2)PressOK tosave,orESC toquitwithoutsaving.

Page 16: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

16

Unitsofmeasurement

Setunitofmeasurementforthevaluesdetectedbythedevice.

Flowrate units of measurement

1)Openinstantrateunitofmeasurementsettingmenu(Setupmenu>Options>Unitsofmeasurem.>Flowrate).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toselectflowrateunitofmeasurement.

1)Selectaunitthrough .

2)Press OK tosave,orESC toquitwithoutsaving.

Volume units of measurement

1)Openvolumeunitofmeasurementsettingmenu(Setupmenu>Options>Unitsofmeasurem.>Volume).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.Press OK toselectvolumeunitofmeasurement.

1)Selectaunitthrough .

2)Press OK tosave,orESC toquitwithoutsaving.

Page 17: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

17

Displaycontrast

Setdisplaycontrast.

Opendisplaycontrastmenu(Setupmenu>Options>Displaycontrast).

Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK toedittheselectedmenuitem.

1)Setavaluethrough .Everytimeyoupressit,valuewillincreaseby5%up

to100%.Usekey todecreasevalue

by5%.2)PressOK tosave,orESC toquitwithoutsaving.

Page 18: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

18

Alarmtones

Enable/disablethealarmtones.

Openalarmtonesmenu(Setupmenu>Options>Alarmtones).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK toedittheselectedmenuitem.

1)Setstatusthrough .

2)PressOK tosave,orESC toquitwithoutsaving.

Keytones

Enable/disablekeytones.

1)Openkeytonesmenu(Setupmenu>Options>Keytones).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK toedittheselectedmenuitem.

1)Setstatusthrough .

2)PressOK tosave,orESC toquitwithoutsaving.

Page 19: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

19

Displaysettings

Themainpageshowsthedisplaydividedintothreehorizontalparts.

Sectorsidentifiedwithsymbols 1 and 2 arethepartialtotalizers,whichcanbeseparatelyreset.Thethirdvalueisinstantflowrate.Everysectorcanbeassignedthedesiredvalue.

Partialtotalizers

Instantflowrate

OpenDisplaysettingsmenu(Setupmenu>Options>Displaysettings).

PressOKtoedittheselectedmenuitem.

1)Selectvaluethrough key.

2)PressOKtoedit,orESCtoquitwithoutsaving.

1)Settotalizertotherequiredvalue

through key.

2)PressOKtosave,orESCtoquitwithoutsaving.Carryoutthesameprocedurefortheother2values.

Page 20: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

20

Operatingmode

Setrequiredoperatingmode.

Openoperatingmodemenu(Setupmenu>Options>Operatingmode).Thedisplaywillshowthecurrentsettingbelowtheselecteditem.PressOK tochangetheoperatingmode.

1)Selecttherequiredoperatingmode

through .

2)PressOK tosave,orESC toquitwithoutsaving.

WARNING:OnceOKispressed,thepageontwhesidewillbedisplayed.Beforechangingoperatingmode,makesurethatallsensorsareDISCONNECTEDfromthedevice.PressOKtoconfirmchanges.ConnectthesensorsREQUIREDFORTHE SET OPERATING MODE.

Page 21: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

21

Setupmanagement

VISIOsettingscanbeloadedfromorsavedonaUSBpendriveinordertoreconfigureit ifrequired,fixproblemsorsetanotherVISIOwithnoneedtorepeatallmanualoperations.Onceinstallationiscompleted,andVISIOoperationhasbeenchecked,werecommendtosaveallsettingsontoaUSBpendrive.TobeabletousethefollowingfunctionsitisnecessarytoinsertaUSBpendriveintherelevantportatthebottomofVISIO.

1)OpenSetupmanagementmenu(Setupmenu>Setupmanagement).

PressOK toedittheselectedmenuitem.

Load setupAllowstoselectaconfigurationfilesavedintheUSBpendriveandtosetVISIOagain.WARNING:ByloadingtheSETUP.BIN filecontainedintheUSBpendriveontotheVISIO,allcurrentsettingswillbelost.

1)Selectthedesiredcontrolthrough key.2)PressOK toconfirmloading,orESC toquitwithoutsaving.

TheSETUP.BINfilecanbeloadedonlyifitissavedintheUSBpendriverootdirectory.Ifsetupdownloadinvolveschangingoperatingmodeandusingdifferentsensorsthantheonesinuse,makesurethatallsensorsareDISCONNECTEDfromthedevice.PressOKtoconfirmloading.Reconnectsensors.

Page 22: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

22

Save setupAllowssavingVISIOconfigurationfileontheUSBpendrive:itwillbepossibletoloaditagainanytimethesamesettingsneedtoberetrieved.

1)Selectthedesiredcontrolthrough

key.2)PressOK toconfirmsaving,orESC toquitwithoutsaving.

IfaSETUP.BINfileisalreadypresentintheUSBpendriverootdirectory,thefilewillbeoverwritten.

Page 23: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

23

Testmenu

ThismenuallowsusertoviewsomedataandcarryoutanoperationtestofVISIO:-Firmwareversion:thedisplayshowsthefirmwareversioninstalled.-Batteryvoltage:thedisplayshowsthepowervoltageofthedevice.

Display test

Displaytestchecksthedevicedisplaycorrectoperation.

1)Opendisplaytestmenu(Setupmenu>Test>Display).Press OK toperformthetest.

Allpixelsondisplayareturnedon.PressESCtogobacktopreviouspage.

Keys test

Keystestchecksthedevicekeyscorrectoperation.

Openkeystestmenu(Setupmenu>Test>Keys).

Press OK toperformthetest.

1)Pressanykeyandthecorrespondingdisplayareawillturnon.PressESC toquit:assoonasyouacknowledgetheswitch-ononofthecorrespondingareaonthedisplay,devicewillgobacktopreviouspage.

Page 24: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

24

Sensors test

Sensorstestcheckscorrectoperationofthesensorsconnectedtothedevice.

Opensensorstestmenu(Setupmenu>Test>Sensors).

Press OK toperformthetest.

Thedisplaywillshowthecurrentsensorreadingbelowtheselecteditem.1)Severalsensorscouldbedisplayed,dependingonthesetoperatingmode.Inthiscase,selectrequiredsensor

through .

2)PressESCtoquit.

Page 25: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

25

USE

Startliquidflowinthesystem.Thedisplaywillstartshowingtheincreasingvalueofthemeasuredfluidquantityandinstantflowrate.

Press keyseveraltimestoviewavalueinextendedmodeuntilvalueisondisplaycentralpart.

Partialtotalizerreset

Toresetatotalizeryoumustviewitinextendedmode.Presskeyseveraltimesuntilvaluetoberesetisatthecentralareaofthedisplay.

Press keyfortwoseconds.

Totalizerresets.

Symbol------indicatesthatflowrateortotalizerexceedmaximumvaluethatcanbedisplayed.Totalizershaveafloatingpointandshowamaximumof4digits.Twodecimalsareshownupto999.99.Onedecimalisshownafterthatand0decimalsareshownwhenvaluereaches10000.

50.00 l2

1

21.84 l/min

999.991050.0 l

2

1

21.84 l/min

1000.010049 l

2

1

21.84 l/min

9999.910050 l

2

1

21.84 l/min

10000 ...

Page 26: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

26

MAINTENANCE / DIAGNOSTICS / REPAIRS

•Cleanonlywithasoftwetcloth.•Donotuseaggressivedetergentsorproducts.•Donotcleanequipmentwithdirectwaterjets.

Troubleshooting

FAULT CAUSE REMEDY

VISIOisoffordoesnotswitchon

Nopowersupply Checkpowercableconnections

DeviceisOFF PresstheONkey

VISIOshowswrongdata

Wrongsetup Checkdisplayeddatasetup

Sensorfault ContactthenearestAssistanceCenterVISIOfault

Fillingpump(ifany)doesnotstart

PumpStopModulenotpowered

Checkpowersupplyconnection

END OF LIFE DISPOSAL

Disposeofthesystemincompliancewiththeestablishedlegislationinthecountryofuse.

Page 27: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

27

TECHNICAL DATA

Devicetechnicaldata

Description VISIO

Display GraphicLCD,128x64pixels,back-lighting

Powersupplyvoltage 9÷16Vdc

Protectionagainstshort-circuit •

Protectionagainstpolarityinversion •

Max.frequency 1.2KHz

Analoginputs 4÷20mA

Digitaloutput-Maxcurrent 100mA

Maximumpowerinput(withnosensorsconnected) 160mA

Operatingtemperature -20°C÷70°C-4°F÷+158°F

Storagetemperature -30°C÷80°C-22°F÷+176°F

Size 126x79x66mm

Weight 245g

Page 28: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

28

Setupmenu

Data Min. Max. Default UoM Notes

Flowmeter Calibration 1 10000 OFF pls/l --

AlarmsMinflowrate 0.1 1000 OFF l/min. Alarmcanbedisabledbysetting

valueto"OFF"

Maxflowrate 0.1 1000 OFF l/min. Alarmcanbedisabledbysettingvalueto"OFF"

Display Contrast 0 100 50 % --

Options

Language - - English -

Availablelanguages:Italiano,English,Español,Português,Français,Deutsch,Cesky,Polski,Русский,Magyar,ニホン .

Flowrateunitsofmeasurement - - l/min. l/min. Availableunitsofmeasurement:

l/min,GPM,m3/h

Volumeunitsofmeasurement - - l liters Availableunitsofmeasurement:

l,gal,m3

Page 29: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

29

GUARANTEE TERMS

1. ARAGs.r.l.guaranteesthisapparatusforaperiodof360days(1year)fromthedateofsaletotheclientuser(dateofthegoodsdeliverynote).Thecomponentsoftheapparatus,thatintheunappealableopinionofARAGarefaultyduetoanoriginaldefectinthematerialorproductionprocess,willberepairedorreplacedfreeofchargeatthenearestAssistanceCenteroperatingatthemomenttherequestforinterventionismade.Thefollowingcostsareexcluded:

- disassemblyandreassemblyoftheapparatusfromtheoriginalsystem;- transportoftheapparatustotheAssistanceCenter.2. Thefollowingarenotcoveredbytheguarantee:- damagecausedbytransport(scratches,dentsandsimilar);- damageduetoincorrectinstallationortofaultsoriginatingfrominsufficientor

inadequatecharacteristicsoftheelectricalsystem,ortoalterationsresultingfromenvironmental,climaticorotherconditions;

- damageduetotheuseofunsuitablechemicalproducts,forspraying,watering,weedkillingoranyothercroptreatment,thatmaydamagetheapparatus;

- malfunctioningcausedbynegligence,mishandling,lackofknowhow,repairsormodificationscarriedoutbyunauthorizedpersonnel;

- incorrectinstallationandregulation;- damageormalfunctioncausedbythelackofordinarymaintenance,suchascleaning

offilters,nozzles,etc.;- anythingthatcanbeconsideredtobenormalwearandtear.3. Repairingtheapparatuswillbecarriedoutwithintimelimitscompatiblewiththe

organizationalneedsoftheAssistanceCenter.Noguaranteeconditionswillberecognizedforthoseunitsorcomponentsthathavenotbeenpreviouslywashedandcleanedtoremoveresidueoftheproductsused;

4. Repairscarriedoutunderguaranteeareguaranteedforoneyear(360days)fromthereplacementorrepairdate.

5. ARAGwillnotrecognizeanyfurtherexpressedorintendedguarantees,apartfromthoselistedhere.NorepresentativeorretailerisauthorizedtotakeonanyotherresponsibilityrelativetoARAGproducts.Theperiodoftheguaranteesrecognizedbylaw,includingthecommercialguaranteesandallowancesforspecialpurposesarelimited,inlengthoftime,tothevaliditiesgivenhere.InnocasewillARAGrecognizelossofprofits,eitherdirect,indirect,specialorsubsequenttoanydamage.

6. ThepartsreplacedunderguaranteeremainthepropertyofARAG.7. Allsafetyinformationpresentinthesalesdocumentsregardinglimitsinuse,

performanceandproductcharacteristicsmustbetransferredtotheenduserasaresponsibilityofthepurchaser.

8. AnycontroversymustbepresentedtotheReggioEmiliaLawCourt.

Page 30: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418

CONFORMITY DECLARATION

The declaration of conformity is available at www.aragnet.com, in the relevant section.

Page 31: Cleveland VOLUME COUNTER VERSION

Cleveland Alliances

01361883418 42048 RUBIERA (Reggio Emilia) - ITALYVia Palladio, 5/ATel. +39 0522 622011Fax +39 0522 [email protected]

Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained in time. Always refer to the internet address www.aragnet.com

D20

287_

GB

-m04

03/2

017