METHOD SUMMARY Client: Waste Management Job Number: 280-52652-1 Preparation Method Method Lab Location Description Matrix: Water Metals (ICP) TAL DEN EPA 200.7 Rev 4.4 Preparation, Total Recoverable Metals TAL DEN EPA 200.7 HEM and SGT-HEM TAL DEN 1664A 1664A HEM and SGT-HEM (SPE) TAL DEN 1664A 1664A Specific Conductance TAL DEN SW846 9050A Solids, Total Suspended (TSS) TAL DEN SM SM 2540D pH TAL DEN SM SM 4500 H+ B Organic Carbon, Total (TOC) TAL DEN SM SM 5310B Lab References: TAL DEN = TestAmerica Denver Method References: 1664A = EPA-821-98-002 EPA = US Environmental Protection Agency SM = "Standard Methods For The Examination Of Water And Wastewater" SW846 = "Test Methods For Evaluating Solid Waste, Physical/Chemical Methods", Third Edition, November 1986 And Its Updates. TestAmerica Denver Page 9 of 34

Upload: others

Post on 15-Jan-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

METHOD SUMMARY

Client: Waste Management Job Number: 280-52652-1

Preparation MethodMethodLab LocationDescription

Matrix: Water

Metals (ICP) TAL DEN EPA 200.7 Rev 4.4

Preparation, Total Recoverable Metals TAL DEN EPA 200.7

HEM and SGT-HEM TAL DEN 1664A 1664A

HEM and SGT-HEM (SPE) TAL DEN 1664A 1664A

Specific Conductance TAL DEN SW846 9050A

Solids, Total Suspended (TSS) TAL DEN SM SM 2540D

pH TAL DEN SM SM 4500 H+ B

Organic Carbon, Total (TOC) TAL DEN SM SM 5310B

Lab References:

TAL DEN = TestAmerica Denver

Method References:

1664A = EPA-821-98-002

EPA = US Environmental Protection Agency

SM = "Standard Methods For The Examination Of Water And Wastewater"

SW846 = "Test Methods For Evaluating Solid Waste, Physical/Chemical Methods", Third Edition, November 1986 And Its

Updates.

TestAmerica Denver Page 9 of 34

METHOD / ANALYST SUMMARY

Client: Waste Management Job Number: 280-52652-1

Method Analyst Analyst ID

Harre, John K JKHEPA 200.7 Rev 4.4

Scott, Samantha J SJSEPA 200.7 Rev 4.4

Benson, Alex F AFB1664A 1664A

Bland, Morgan R MRBSW846 9050A

Woolley, Mark - MW1SM SM 2540D

Bland, Morgan R MRBSM SM 4500 H+ B

Jewell, Connie C CCJSM SM 5310B

TestAmerica Denver

Page 10 of 34

SAMPLE SUMMARY

Client: Waste Management Job Number: 280-52652-1

Client Sample IDLab Sample ID Client Matrix Sampled Received

Date/Time Date/Time

280-52652-1 OUTFALL001_D-1 Water 02/28/2014 1410 03/03/2014 0830

280-52652-2 OUTFALL B Water 02/28/2014 1300 03/03/2014 0830

280-52652-3 OUTFALL NORTH Water 02/28/2014 1340 03/03/2014 0830

TestAmerica Denver Page 11 of 34

SAMPLE RESULTS

TestAmerica Denver

Page 12 of 34

Analytical Data

Client: Waste Management Job Number: 280-52652-1

Client Sample ID:

Lab Sample ID:

OUTFALL001_D-1

Client Matrix:

280-52652-1

Water

Date Sampled: 02/28/2014 1410

Date Received: 03/03/2014 0830

200.7 Rev 4.4 Metals (ICP)-Total Recoverable

200.7 Rev 4.4 Instrument ID:

Lab File ID: 26a030514a.asc

Dilution: 5.0 Initial Weight/Volume: 50 mL

03/05/2014 1450 Final Weight/Volume: 50 mL

03/04/2014 0730

200.7

MT_026

Analysis Date:

Prep Date:

Analysis Batch: 280-215710

280-215248Prep Batch:

Analysis Method:

Prep Method:

Analyte Result (mg/L) Qualifier MDL RL

790 0.110.11Iron

TestAmerica Denver Page 13 of 34

Analytical Data

Client: Waste Management Job Number: 280-52652-1

Client Sample ID:

Lab Sample ID:

OUTFALL B

Client Matrix:

280-52652-2

Water

Date Sampled: 02/28/2014 1300

Date Received: 03/03/2014 0830

200.7 Rev 4.4 Metals (ICP)-Total Recoverable

200.7 Rev 4.4 Instrument ID:

Lab File ID: 26a030414c.asc

Dilution: 1.0 Initial Weight/Volume: 50 mL

03/04/2014 2211 Final Weight/Volume: 50 mL

03/04/2014 0730

200.7

MT_026

Analysis Date:

Prep Date:

Analysis Batch: 280-215498

280-215248Prep Batch:

Analysis Method:

Prep Method:

Analyte Result (mg/L) Qualifier MDL RL

65 0.100.022Iron

TestAmerica Denver Page 14 of 34

Analytical Data

Client: Waste Management Job Number: 280-52652-1

Client Sample ID:

Lab Sample ID:

OUTFALL NORTH

Client Matrix:

280-52652-3

Water

Date Sampled: 02/28/2014 1340

Date Received: 03/03/2014 0830

200.7 Rev 4.4 Metals (ICP)-Total Recoverable

200.7 Rev 4.4 Instrument ID:

Lab File ID: 25A2030614.asc

Dilution: 1.0 Initial Weight/Volume: 50 mL

03/06/2014 1739 Final Weight/Volume: 50 mL

03/06/2014 0800

200.7

MT_025

Analysis Date:

Prep Date:

Analysis Batch: 280-215883

280-215415Prep Batch:

Analysis Method:

Prep Method:

Analyte Result (mg/L) Qualifier MDL RL

12 0.100.022Iron

TestAmerica Denver Page 15 of 34

Analytical Data

Client: Waste Management Job Number: 280-52652-1

General Chemistry

Client Sample ID:

Lab Sample ID:

OUTFALL001_D-1

Client Matrix:

280-52652-1

Water

Date Sampled: 02/28/2014 1410

Date Received: 03/03/2014 0830

Analyte Result Qual Units MDL RL Dil Method

HEM ND mg/L 4.0 5.0 1.0 1664A

Analysis Date: 03/10/2014 1251Analysis Batch: 280-216199

Prep Batch: 280-216121 Prep Date: 03/10/2014 0918

Total Suspended Solids 26000 mg/L 55 55 1.0 SM 2540D

Analysis Date: 03/04/2014 1515Analysis Batch: 280-215401

TOC Result 1 17 B mg/L 0.16 1.0 1.0 SM 5310B

Analysis Date: 03/07/2014 1829Analysis Batch: 280-216059

TOC Result 2 17 B mg/L 0.16 1.0 1.0 SM 5310B

Analysis Date: 03/07/2014 1829Analysis Batch: 280-216059

Analyte Result Qual Units RL RL Dil Method

Specific Conductance 540 umhos/cm 2.0 2.0 1.0 9050A

Analysis Date: 03/07/2014 1944Analysis Batch: 280-216025

pH 8.37 HF SU 0.100 0.100 1.0 SM 4500 H+ B

Analysis Date: 03/03/2014 1955Analysis Batch: 280-215217

TestAmerica Denver Page 16 of 34

Analytical Data

Client: Waste Management Job Number: 280-52652-1

General Chemistry

Client Sample ID:

Lab Sample ID:

OUTFALL B

Client Matrix:

280-52652-2

Water

Date Sampled: 02/28/2014 1300

Date Received: 03/03/2014 0830

Analyte Result Qual Units MDL RL Dil Method

HEM 3.2 J mg/L 3.2 5.0 1.0 1664A

Analysis Date: 03/10/2014 1251Analysis Batch: 280-216199

Prep Batch: 280-216121 Prep Date: 03/10/2014 0918

Total Suspended Solids 1800 mg/L 18 18 1.0 SM 2540D

Analysis Date: 03/04/2014 1515Analysis Batch: 280-215401

TOC Result 1 4.2 B mg/L 0.16 1.0 1.0 SM 5310B

Analysis Date: 03/07/2014 1922Analysis Batch: 280-216059

TOC Result 2 4.1 B mg/L 0.16 1.0 1.0 SM 5310B

Analysis Date: 03/07/2014 1922Analysis Batch: 280-216059

Analyte Result Qual Units RL RL Dil Method

Specific Conductance 190 umhos/cm 2.0 2.0 1.0 9050A

Analysis Date: 03/07/2014 1944Analysis Batch: 280-216025

pH 8.60 HF SU 0.100 0.100 1.0 SM 4500 H+ B

Analysis Date: 03/03/2014 1955Analysis Batch: 280-215217

TestAmerica Denver Page 17 of 34

Analytical Data

Client: Waste Management Job Number: 280-52652-1

General Chemistry

Client Sample ID:

Lab Sample ID:

OUTFALL NORTH

Client Matrix:

280-52652-3

Water

Date Sampled: 02/28/2014 1340

Date Received: 03/03/2014 0830

Analyte Result Qual Units MDL RL Dil Method

HEM ND mg/L 1.6 5.0 1.0 1664A

Analysis Date: 03/10/2014 1251Analysis Batch: 280-216199

Prep Batch: 280-216121 Prep Date: 03/10/2014 0918

Total Suspended Solids 240 mg/L 3.7 4.0 1.0 SM 2540D

Analysis Date: 03/04/2014 1515Analysis Batch: 280-215401

TOC Result 1 8.0 B mg/L 0.16 1.0 1.0 SM 5310B

Analysis Date: 03/07/2014 1938Analysis Batch: 280-216059

TOC Result 2 8.3 B mg/L 0.16 1.0 1.0 SM 5310B

Analysis Date: 03/07/2014 1938Analysis Batch: 280-216059

Analyte Result Qual Units RL RL Dil Method

Specific Conductance 500 umhos/cm 2.0 2.0 1.0 9050A

Analysis Date: 03/07/2014 1944Analysis Batch: 280-216025

pH 7.64 HF SU 0.100 0.100 1.0 SM 4500 H+ B

Analysis Date: 03/04/2014 1734Analysis Batch: 280-215418

TestAmerica Denver Page 18 of 34

DATA REPORTING QUALIFIERS

Client: Waste Management Job Number: 280-52652-1

Lab Section Qualifier Description

Metals

MS, MSD: The analyte present in the original sample is greater than 4

times the matrix spike concentration; therefore, control limits are not

applicable.

4

General Chemistry

Compound was found in the blank and sample.B

Field parameter with a holding time of 15 minutesHF

Result is less than the RL but greater than or equal to the MDL and the

concentration is an approximate value.

J

TestAmerica Denver Page 19 of 34

QUALITY CONTROL RESULTS

TestAmerica Denver

Page 20 of 34

Quality Control Results

Client: Waste Management Job Number: 280-52652-1

QC Association Summary

Lab Sample ID Client Sample ID Client Matrix Method Prep Batch

Report

Basis

Metals

Prep Batch: 280-215248

Lab Control Sample Water 200.7LCS 280-215248/2-A R

Method Blank Water 200.7MB 280-215248/1-A R

WaterOUTFALL001_D-1 200.7280-52652-1 R

WaterOUTFALL B 200.7280-52652-2 R

Matrix Spike Water 200.7280-52652-2MS R

Matrix Spike Duplicate Water 200.7280-52652-2MSD R

Prep Batch: 280-215415

Lab Control Sample Water 200.7LCS 280-215415/2-A R

Method Blank Water 200.7MB 280-215415/1-A R

WaterOUTFALL NORTH 200.7280-52652-3 R

Matrix Spike Water 200.7280-52663-F-4-B MS R

Matrix Spike Duplicate Water 200.7280-52663-F-4-C MSD R

Analysis Batch:280-215498

Lab Control Sample Water 280-215248200.7 Rev 4.4LCS 280-215248/2-A R

Method Blank Water 280-215248200.7 Rev 4.4MB 280-215248/1-A R

Water 280-215248OUTFALL B 200.7 Rev 4.4280-52652-2 R

Matrix Spike Water 280-215248200.7 Rev 4.4280-52652-2MS R

Matrix Spike Duplicate Water 280-215248200.7 Rev 4.4280-52652-2MSD R

Analysis Batch:280-215710

Water 280-215248OUTFALL001_D-1 200.7 Rev 4.4280-52652-1 R

Analysis Batch:280-215883

Lab Control Sample Water 280-215415200.7 Rev 4.4LCS 280-215415/2-A R

Method Blank Water 280-215415200.7 Rev 4.4MB 280-215415/1-A R

Water 280-215415OUTFALL NORTH 200.7 Rev 4.4280-52652-3 R

Matrix Spike Water 280-215415200.7 Rev 4.4280-52663-F-4-B MS R

Matrix Spike Duplicate Water 280-215415200.7 Rev 4.4280-52663-F-4-C MSD R

Report Basis

R = Total Recoverable

TestAmerica Denver

Page 21 of 34

Quality Control Results

Client: Waste Management Job Number: 280-52652-1

QC Association Summary

Lab Sample ID Client Sample ID Client Matrix Method Prep Batch

Report

Basis

General Chemistry

Analysis Batch:280-215217

Lab Control Sample Water SM 4500 H+ BLCS 280-215217/4 T

Lab Control Sample Duplicate Water SM 4500 H+ BLCSD 280-215217/5 T

Duplicate Water SM 4500 H+ B280-52534-A-25 DU T

WaterOUTFALL001_D-1 SM 4500 H+ B280-52652-1 T

WaterOUTFALL B SM 4500 H+ B280-52652-2 T

Analysis Batch:280-215401

Lab Control Sample Water SM 2540DLCS 280-215401/1 T

Lab Control Sample Duplicate Water SM 2540DLCSD 280-215401/2 T

Method Blank Water SM 2540DMB 280-215401/3 T

Duplicate Water SM 2540D280-52594-A-1 DU T

WaterOUTFALL001_D-1 SM 2540D280-52652-1 T

WaterOUTFALL B SM 2540D280-52652-2 T

WaterOUTFALL NORTH SM 2540D280-52652-3 T

Analysis Batch:280-215418

Lab Control Sample Water SM 4500 H+ BLCS 280-215418/4 T

Lab Control Sample Duplicate Water SM 4500 H+ BLCSD 280-215418/5 T

Duplicate Water SM 4500 H+ B280-52576-E-3 DU T

WaterOUTFALL NORTH SM 4500 H+ B280-52652-3 T

Analysis Batch:280-216025

Lab Control Sample Water 9050ALCS 280-216025/3 T

Lab Control Sample Duplicate Water 9050ALCSD 280-216025/4 T

Method Blank Water 9050AMB 280-216025/5 T

WaterOUTFALL001_D-1 9050A280-52652-1 T

Duplicate Water 9050A280-52652-1DU T

WaterOUTFALL B 9050A280-52652-2 T

WaterOUTFALL NORTH 9050A280-52652-3 T

Analysis Batch:280-216059

Lab Control Sample Water SM 5310BLCS 280-216059/3 T

Lab Control Sample Duplicate Water SM 5310BLCSD 280-216059/4 T

Method Blank Water SM 5310BMB 280-216059/5 T

WaterOUTFALL001_D-1 SM 5310B280-52652-1 T

Matrix Spike Water SM 5310B280-52652-1MS T

Matrix Spike Duplicate Water SM 5310B280-52652-1MSD T

WaterOUTFALL B SM 5310B280-52652-2 T

WaterOUTFALL NORTH SM 5310B280-52652-3 T

TestAmerica Denver

Page 22 of 34

Quality Control Results

Client: Waste Management Job Number: 280-52652-1

QC Association Summary

Lab Sample ID Client Sample ID Client Matrix Method Prep Batch

Report

Basis

General Chemistry

Prep Batch: 280-216121

Lab Control Sample Water 1664ALCS 280-216121/2-A T

Lab Control Sample Duplicate Water 1664ALCSD 280-216121/3-A T

Method Blank Water 1664AMB 280-216121/1-A T

WaterOUTFALL001_D-1 1664A280-52652-1 T

WaterOUTFALL B 1664A280-52652-2 T

WaterOUTFALL NORTH 1664A280-52652-3 T

Analysis Batch:280-216199

Lab Control Sample Water 280-2161211664ALCS 280-216121/2-A T

Lab Control Sample Duplicate Water 280-2161211664ALCSD 280-216121/3-A T

Method Blank Water 280-2161211664AMB 280-216121/1-A T

Water 280-216121OUTFALL001_D-1 1664A280-52652-1 T

Water 280-216121OUTFALL B 1664A280-52652-2 T

Water 280-216121OUTFALL NORTH 1664A280-52652-3 T

Report Basis

T = Total

TestAmerica Denver

Page 23 of 34

Quality Control Results

Job Number: 280-52652-1Client: Waste Management

WaterClient Matrix:

1.0Dilution:

Lab Sample ID:

03/04/2014 2200

Method Blank - Batch: 280-215248

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

26a030414c.asc

50 mL

50 mLUnits: mg/L

Method: 200.7 Rev 4.4

Preparation: 200.7

Total Recoverable

MT_026MB 280-215248/1-A

Analysis Date:

Analysis Batch:

Prep Batch:

Leach Batch:

280-215498

280-215248

N/A

Prep Date: 03/04/2014 0730

Leach Date: N/A

Analyte Result Qual MDL RL

ND 0.100.022Iron

Water

1.0

Lab Control Sample - Batch: 280-215248

Client Matrix:

Lab Sample ID:

Dilution:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

26a030414c.asc

50 mL

50 mLUnits: mg/L

Method: 200.7 Rev 4.4

Preparation: 200.7

Total Recoverable

MT_026LCS 280-215248/2-A

Analysis Date: 03/04/2014 2202

Analysis Batch:

Prep Batch:

Leach Batch:

280-215498

280-215248

N/A

Prep Date:

Leach Date:

03/04/2014 0730

N/A

Analyte QualLimit% Rec.ResultSpike Amount

1.00 1.00 100 89 - 115Iron

Dilution:

Dilution:

03/04/2014 2215

03/04/2014 2217

Water

Matrix Spike/

Matrix Spike Duplicate Recovery Report - Batch: 280-215248

1.0

1.0

Client Matrix:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

Client Matrix: Water

03/04/2014 0730

03/04/2014 0730

26a030414c.asc

50 mL

50 mL

26a030414c.asc

50 mL

50 mL

Method: 200.7 Rev 4.4

Preparation: 200.7

Total Recoverable

MT_026

MT_026

280-52652-2

280-52652-2

MS Lab Sample ID:

MSD Lab Sample ID:

Analysis Date:

Prep Date:

Leach Date: N/A

Analysis Date:

Prep Date:

Leach Date: N/A

Analysis Batch:

Prep Batch:

Leach Batch:

280-215498

280-215248

Analysis Batch:

Prep Batch:

Leach Batch:

280-215498

280-215248

N/A

N/A

Analyte RPD LimitRPDLimit

% Rec.

MS MSD MS Qual MSD Qual

718 1581 89 - 115 11 20 4 4Iron

TestAmerica Denver Page 24 of 34

Quality Control Results

Job Number: 280-52652-1Client: Waste Management

WaterClient Matrix:

1.0Dilution:

Lab Sample ID:

03/06/2014 1732

Method Blank - Batch: 280-215415

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

25A2030614.asc

50 mL

50 mLUnits: mg/L

Method: 200.7 Rev 4.4

Preparation: 200.7

Total Recoverable

MT_025MB 280-215415/1-A

Analysis Date:

Analysis Batch:

Prep Batch:

Leach Batch:

280-215883

280-215415

N/A

Prep Date: 03/06/2014 0800

Leach Date: N/A

Analyte Result Qual MDL RL

ND 0.100.022Iron

Water

1.0

Lab Control Sample - Batch: 280-215415

Client Matrix:

Lab Sample ID:

Dilution:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

25A2030614.asc

50 mL

50 mLUnits: mg/L

Method: 200.7 Rev 4.4

Preparation: 200.7

Total Recoverable

MT_025LCS 280-215415/2-A

Analysis Date: 03/06/2014 1734

Analysis Batch:

Prep Batch:

Leach Batch:

280-215883

280-215415

N/A

Prep Date:

Leach Date:

03/06/2014 0800

N/A

Analyte QualLimit% Rec.ResultSpike Amount

1.00 1.05 105 89 - 115Iron

Dilution:

Dilution:

03/06/2014 1803

03/06/2014 1805

Water

Matrix Spike/

Matrix Spike Duplicate Recovery Report - Batch: 280-215415

1.0

1.0

Client Matrix:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

Client Matrix: Water

03/06/2014 0800

03/06/2014 0800

25A2030614.asc

50 mL

50 mL

25A2030614.asc

50 mL

50 mL

Method: 200.7 Rev 4.4

Preparation: 200.7

Total Recoverable

MT_025

MT_025

280-52663-F-4-B MS

280-52663-F-4-C MSD

MS Lab Sample ID:

MSD Lab Sample ID:

Analysis Date:

Prep Date:

Leach Date: N/A

Analysis Date:

Prep Date:

Leach Date: N/A

Analysis Batch:

Prep Batch:

Leach Batch:

280-215883

280-215415

Analysis Batch:

Prep Batch:

Leach Batch:

280-215883

280-215415

N/A

N/A

Analyte RPD LimitRPDLimit

% Rec.

MS MSD MS Qual MSD Qual

107 105 89 - 115 1 20Iron

TestAmerica Denver Page 25 of 34

Quality Control Results

Job Number: 280-52652-1Client: Waste Management

WaterClient Matrix:

1.0Dilution:

Lab Sample ID:

03/10/2014 1251

Method Blank - Batch: 280-216121

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

1000 mL

1000 mLUnits: mg/L

Method: 1664A

Preparation: 1664A

No Equipment AssignedMB 280-216121/1-A

Analysis Date:

Analysis Batch:

Prep Batch:

Leach Batch:

280-216199

280-216121 N/A

N/A

Prep Date: 03/10/2014 0918

Leach Date: N/A

Analyte Result Qual MDL RL

ND 5.01.6HEM

Dilution:

Dilution:

03/10/2014 1251

Lab Control Sample/

Lab Control Sample Duplicate Recovery Report - Batch: 280-216121

1.0

1.0

Water

LCS Lab Sample ID:

LCSD Lab Sample ID:

Client Matrix:

Units:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

Client Matrix: Water

Units:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

mg/L

1000 mL

1000 mL

1000 mL

1000 mLmg/L

03/10/2014 0918

Method: 1664A

Preparation: 1664A

N/A

N/A

No Equipment Assigned

No Equipment Assigned

LCS 280-216121/2-A

LCSD 280-216121/3-A

Analysis Date:

Prep Date:

Leach Date:

03/10/2014 1251

03/10/2014 0918

Analysis Batch:

Prep Batch:

Leach Batch:

280-216199

280-216121

Analysis Date:

Prep Date:

Leach Date:

Analysis Batch:

Prep Batch:

Leach Batch:

280-216199

280-216121

N/A

N/A

N/A

N/A

Analyte LCSD QualLCS QualRPD LimitRPDLimitLCSDLCS

% Rec.

8384 78 - 114 1 18HEM

TestAmerica Denver Page 26 of 34

Quality Control Results

Job Number: 280-52652-1Client: Waste Management

WaterClient Matrix:

1.0Dilution:

Lab Sample ID:

03/07/2014 1944

Method Blank - Batch: 280-216025

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume: 25 mLUnits: umhos/cm

Method: 9050A

Preparation: N/A

No Equipment AssignedMB 280-216025/5

Analysis Date:

Analysis Batch:

Prep Batch:

Leach Batch:

280-216025

N/AN/A

N/A

Prep Date:

Leach Date:

N/A

N/A

Analyte Result Qual RL RL

ND 2.02.0Specific Conductance

Dilution:

Dilution:

03/07/2014 1944

Lab Control Sample/

Lab Control Sample Duplicate Recovery Report - Batch: 280-216025

1.0

1.0

Water

LCS Lab Sample ID:

LCSD Lab Sample ID:

Client Matrix:

Units:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

Client Matrix: Water

Units:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

umhos/cm

N/A

25 mL

25 mLumhos/cm

Method: 9050A

Preparation: N/A

N/A

N/A

N/A

No Equipment Assigned

No Equipment Assigned

LCS 280-216025/3

LCSD 280-216025/4

Analysis Date:

Prep Date:

Leach Date:

03/07/2014 1944

Analysis Batch:

Prep Batch:

Leach Batch:

280-216025

Analysis Date:

Prep Date:

Leach Date:

Analysis Batch:

Prep Batch:

Leach Batch:

280-216025

N/A

N/A

N/A

N/A

N/A

N/A

Analyte LCSD QualLCS QualRPD LimitRPDLimitLCSDLCS

% Rec.

96100 90 - 110 4 10Specific Conductance

umhos/cmUnits:

Water

Dilution: 1.0

Duplicate - Batch: 280-216025

Lab Sample ID:

Client Matrix:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume: 25 mL

Method: 9050A

Preparation: N/A

No Equipment Assigned280-52652-1

Analysis Date:

Analysis Batch:

03/07/2014 1944

Prep Batch:

Leach Batch:

N/AN/A

N/A

280-216025

Prep Date:

Leach Date:

N/A

N/A

Analyte QualLimitRPDResultSample Result/Qual

541540 0.6 10Specific Conductance

TestAmerica Denver Page 27 of 34

Quality Control Results

Job Number: 280-52652-1Client: Waste Management

WaterClient Matrix:

1.0Dilution:

Lab Sample ID:

03/04/2014 1515

Method Blank - Batch: 280-215401

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

250 mL

250 mLUnits: mg/L

Method: SM 2540D

Preparation: N/A

No Equipment AssignedMB 280-215401/3

Analysis Date:

Analysis Batch:

Prep Batch:

Leach Batch:

280-215401

N/AN/A

N/A

Prep Date:

Leach Date:

N/A

N/A

Analyte Result Qual MDL RL

ND 4.01.1Total Suspended Solids

Dilution:

Dilution:

03/04/2014 1515

Lab Control Sample/

Lab Control Sample Duplicate Recovery Report - Batch: 280-215401

1.0

1.0

Water

LCS Lab Sample ID:

LCSD Lab Sample ID:

Client Matrix:

Units:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

Client Matrix: Water

Units:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

mg/L

N/A

100 mL

250 mL

100 mL

250 mLmg/L

Method: SM 2540D

Preparation: N/A

N/A

N/A

N/A

No Equipment Assigned

No Equipment Assigned

LCS 280-215401/1

LCSD 280-215401/2

Analysis Date:

Prep Date:

Leach Date:

03/04/2014 1515

Analysis Batch:

Prep Batch:

Leach Batch:

280-215401

Analysis Date:

Prep Date:

Leach Date:

Analysis Batch:

Prep Batch:

Leach Batch:

280-215401

N/A

N/A

N/A

N/A

N/A

N/A

Analyte LCSD QualLCS QualRPD LimitRPDLimitLCSDLCS

% Rec.

8991 86 - 114 2 20Total Suspended Solids

mg/LUnits:

Water

Dilution: 1.0

Duplicate - Batch: 280-215401

Lab Sample ID:

Client Matrix:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

250 mL

250 mL

Method: SM 2540D

Preparation: N/A

No Equipment Assigned280-52594-A-1 DU

Analysis Date:

Analysis Batch:

03/04/2014 1515

Prep Batch:

Leach Batch:

N/AN/A

N/A

280-215401

Prep Date:

Leach Date:

N/A

N/A

Analyte QualLimitRPDResultSample Result/Qual

5.204.4 17 10Total Suspended Solids

TestAmerica Denver Page 28 of 34

Quality Control Results

Job Number: 280-52652-1Client: Waste Management

Dilution:

Dilution:

03/03/2014 1605

Lab Control Sample/

Lab Control Sample Duplicate Recovery Report - Batch: 280-215217

1.0

1.0

Water

LCS Lab Sample ID:

LCSD Lab Sample ID:

Client Matrix:

Units:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

Client Matrix: Water

Units:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

SU

N/A

1 mL

1 mLSU

Method: SM 4500 H+ B

Preparation: N/A

N/A

N/A

N/A

No Equipment Assigned

No Equipment Assigned

LCS 280-215217/4

LCSD 280-215217/5

Analysis Date:

Prep Date:

Leach Date:

03/03/2014 1605

Analysis Batch:

Prep Batch:

Leach Batch:

280-215217

Analysis Date:

Prep Date:

Leach Date:

Analysis Batch:

Prep Batch:

Leach Batch:

280-215217

N/A

N/A

N/A

N/A

N/A

N/A

Analyte LCSD QualLCS QualRPD LimitRPDLimitLCSDLCS

% Rec.

100100 99 - 101 0 5pH

SUUnits:

Water

Dilution: 1.0

Duplicate - Batch: 280-215217

Lab Sample ID:

Client Matrix:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume: 1 mL

Method: SM 4500 H+ B

Preparation: N/A

No Equipment Assigned280-52534-A-25 DU

Analysis Date:

Analysis Batch:

03/03/2014 1606

Prep Batch:

Leach Batch:

N/AN/A

N/A

280-215217

Prep Date:

Leach Date:

N/A

N/A

Analyte QualLimitRPDResultSample Result/Qual

5.6405.61 0.5 5pH

TestAmerica Denver Page 29 of 34

Quality Control Results

Job Number: 280-52652-1Client: Waste Management

Dilution:

Dilution:

03/04/2014 1733

Lab Control Sample/

Lab Control Sample Duplicate Recovery Report - Batch: 280-215418

1.0

1.0

Water

LCS Lab Sample ID:

LCSD Lab Sample ID:

Client Matrix:

Units:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

Client Matrix: Water

Units:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

SU

N/A

1 mL

1 mLSU

Method: SM 4500 H+ B

Preparation: N/A

N/A

N/A

N/A

No Equipment Assigned

No Equipment Assigned

LCS 280-215418/4

LCSD 280-215418/5

Analysis Date:

Prep Date:

Leach Date:

03/04/2014 1733

Analysis Batch:

Prep Batch:

Leach Batch:

280-215418

Analysis Date:

Prep Date:

Leach Date:

Analysis Batch:

Prep Batch:

Leach Batch:

280-215418

N/A

N/A

N/A

N/A

N/A

N/A

Analyte LCSD QualLCS QualRPD LimitRPDLimitLCSDLCS

% Rec.

100100 99 - 101 0 5pH

SUUnits:

Water

Dilution: 1.0

Duplicate - Batch: 280-215418

Lab Sample ID:

Client Matrix:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume: 1 mL

Method: SM 4500 H+ B

Preparation: N/A

No Equipment Assigned280-52576-E-3 DU

Analysis Date:

Analysis Batch:

03/04/2014 1734

Prep Batch:

Leach Batch:

N/AN/A

N/A

280-215418

Prep Date:

Leach Date:

N/A

N/A

Analyte QualLimitRPDResultSample Result/Qual

7.1807.16 0.3 5pH

TestAmerica Denver Page 30 of 34

Quality Control Results

Job Number: 280-52652-1Client: Waste Management

WaterClient Matrix:

1.0Dilution:

Lab Sample ID:

03/07/2014 1325

Method Blank - Batch: 280-216059

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

030714.txt

Units: mg/L

Method: SM 5310B

Preparation: N/A

WC_SHI2MB 280-216059/5

Analysis Date:

Analysis Batch:

Prep Batch:

Leach Batch:

280-216059

N/A

N/A

Prep Date:

Leach Date:

N/A

N/A

Analyte Result Qual MDL RL

0.288 J 1.00.16TOC Result 1

0.236 J 1.00.16TOC Result 2

Dilution:

Dilution:

03/07/2014 1308

Lab Control Sample/

Lab Control Sample Duplicate Recovery Report - Batch: 280-216059

1.0

1.0

Water

LCS Lab Sample ID:

LCSD Lab Sample ID:

Client Matrix:

Units:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

Client Matrix: Water

Units:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

mg/L

N/A

030714.txt

200 mL

030714.txt

200 mLmg/L

Method: SM 5310B

Preparation: N/A

N/A

WC_SHI2

WC_SHI2

LCS 280-216059/3

LCSD 280-216059/4

Analysis Date:

Prep Date:

Leach Date:

03/07/2014 1250

Analysis Batch:

Prep Batch:

Leach Batch:

280-216059

Analysis Date:

Prep Date:

Leach Date:

Analysis Batch:

Prep Batch:

Leach Batch:

280-216059

N/A

N/A

N/A

N/A

N/A

N/A

Analyte LCSD QualLCS QualRPD LimitRPDLimitLCSDLCS

% Rec.

107107 88 - 112 1 15TOC Result 1

106106 88 - 112 0 15TOC Result 2

TestAmerica Denver Page 31 of 34

Quality Control Results

Job Number: 280-52652-1Client: Waste Management

Dilution:

Dilution:

03/07/2014 1847

03/07/2014 1905

Water

Matrix Spike/

Matrix Spike Duplicate Recovery Report - Batch: 280-216059

1.0

1.0

Client Matrix:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

Instrument ID:

Lab File ID:

Initial Weight/Volume:

Final Weight/Volume:

Client Matrix: Water

030714.txt

50 mL

030714.txt

50 mL

Method: SM 5310B

Preparation: N/A

WC_SHI2

WC_SHI2

280-52652-1

280-52652-1

MS Lab Sample ID:

MSD Lab Sample ID:

Analysis Date:

Prep Date:

Leach Date:

N/A

N/A

Analysis Date:

Prep Date:

Leach Date:

N/A

N/A

Analysis Batch:

Prep Batch:

Leach Batch:

280-216059

Analysis Batch:

Prep Batch:

Leach Batch:

280-216059

N/A

N/A

N/A

N/A

Analyte RPD LimitRPDLimit

% Rec.

MS MSD MS Qual MSD Qual

105 104 88 - 112 1 15TOC Result 1

102 102 88 - 112 0 15TOC Result 2

TestAmerica Denver Page 32 of 34

Page 33 of 34

Login Sample Receipt Checklist

Client: Waste Management Job Number: 280-52652-1

Login Number: 52652

Question Answer Comment

Creator: Dedio, Michael T

List Source: TestAmerica Denver

List Number: 1

TrueRadioactivity either was not measured or, if measured, is at or below

background

TrueThe cooler's custody seal, if present, is intact.

TrueThe cooler or samples do not appear to have been compromised or

tampered with.

TrueSamples were received on ice.

TrueCooler Temperature is acceptable.

TrueCooler Temperature is recorded.

TrueCOC is present.

TrueCOC is filled out in ink and legible.

TrueCOC is filled out with all pertinent information.

TrueIs the Field Sampler's name present on COC?

TrueThere are no discrepancies between the sample IDs on the containers and

the COC.

TrueSamples are received within Holding Time.

TrueSample containers have legible labels.

TrueContainers are not broken or leaking.

TrueSample collection date/times are provided.

TrueAppropriate sample containers are used.

TrueSample bottles are completely filled.

N/ASample Preservation Verified

TrueThere is sufficient vol. for all requested analyses, incl. any requested

MS/MSDs

N/AVOA sample vials do not have headspace or bubble is <6mm (1/4") in

diameter.

TrueIf necessary, staff have been informed of any short hold time or quick TAT

needs

TrueMultiphasic samples are not present.

TrueSamples do not require splitting or compositing.

TrueSampling Company provided.

FalseSamples received within 48 hours of sampling.

TrueSamples requiring field filtration have been filtered in the field.

N/AChlorine Residual checked.

TestAmerica Denver Page 34 of 34

State of California STATE WATER RESOURCES CONTROL BOARD

ANNUAL REPORT FOR

STORM WATER DISCHARGES ASSOCIATED WITH INDUSTRIAL ACTIVITIES

Reporting Period July 1, through June 30, An annual report is required to be submitted to your local Regional Water Quality Control Board (Regional Board) by July 1 of each year. This document must be certified and signed, under penalty of perjury, by the appropriate official of your company. Many of the Annual Report questions require an explanation. Please provide explanations on a separate sheet as an attachment. Retain a copy of the completed Annual Report for your records. Please circle or highlight any information contained in Items A, B, and C below that is new or revised so we can update our records. Please remember that a Notice of Termination and new Notice of Intent are required whenever a facility operation is relocated or changes ownership. If you have any questions, please contact your Regional Board Industrial Storm Water Permit Contact. The names, telephone numbers and e-mail addresses of the Regional Board contacts, as well as the Regional Board office addresses can be found at http://www.swrcb.ca.gov/stormwtr/contact.html. To find your Regional Board information, match the first digit of your WDID number with the corresponding number that appears in parenthesis on the first line of each Regional Board office. GENERAL INFORMATION:

A. Facility Information: Facility WDID No:

Facility Business Name: Contact Person:

Physical Address: e-mail:

City: CA Zip: Phone:

SIC Code(s):

B. Facility Operator Information: Operator Name: Contact Person:

Mailing Address: e-mail:

City: State: Zip: Phone:

C. Facility Billing Information: Operator Name: Contact Person:

Mailing Address: e-mail:

City: State: Zip: Phone: ______________

4953-Refuse Systems

Corona 951-277-5106

[email protected]

Corona

Waste Management Inc

10910 Dawson Canyon Rd

Cody Gowgill

8 33I000559

951-277-5106

Cody Gowgill

91719

2013

2013

2014

2014

Waste Mgt Inc El Sobrante Land

10910 Dawson Canyon Rd

CA

[email protected]

92883

ANNUAL REPORT

-2-

SPECIFIC INFORMATION

MONITORING AND REPORTING PROGRAM

D. SAMPLING AND ANALYSIS EXEMPTIONS AND REDUCTIONS

1. For the reporting period, was your facility exempt from collecting and analyzing samples from two storm events inaccordance with sections B.12 or 15 of the General Permit?

YES Go to Item D.2 NO Go to Section E

2. Indicate the reason your facility is exempt from collecting and analyzing samples from two storm events. Attach a copy of the first page of the appropriate certification if you check boxes ii, iii, iv, or v.

i. Participating in an Approved Group Monitoring Plan Group Name:

ii. Submitted No Exposure Certification (NEC) Date Submitted:

Re-evaluation Date: _

Does facility continue to satisfy NEC conditions? YES NO

iii. Submitted Sampling Reduction Certification (SRC) Date Submitted:

Re-evaluation Date: _

Does facility continue to satisfy SRC conditions? YES NO

iv. Received Regional Board Certification Certification Date:

v. Received Local Agency Certification Cetification Date:

3. If you checked boxes i or iii above, were you scheduled to sample one storm event during the reporting year?

YES Go to Section E NO Go to Section F

4. If you checked boxes ii, iv, or v, go to Section F.

E. SAMPLING AND ANALYSIS RESULTS

1. How many storm events did you sample? If less than 2, attach explanation (if you checked item D.2.i or iii. above, only attach explanation if youanswer “0”).

2. Did you collect storm water samples from the first storm of the wet season that produced a discharge duringscheduled facility operating hours? (Section B.5 of the General Permit)

YES NO, attach explanation (Please note that ifyou do not sample the first storm event, you arestill required to sample 2 storm events)

3. How many storm water discharge locations are at your facility?

1

7

2013 2014

-3-

4. For each storm event sampled, did you collect and analyze asample from each of the facilitys’ storm water discharge locations? YES, go to Item E.6 NO

5. Was sample collection or analysis reduced in accordancewith Section B.7.d of the General Permit? NO YES, attach explanation

If “YES”, attach documentation supporting your determinationthat two or more drainage areas are substantially identical.

Date facility’s drainage areas were last evaluated _

6. Were all samples collected during the first hour of discharge? YES NO, attach explanation

7. Was all storm water sampling preceded by three (3)working days without a storm water discharge? YES NO, attach explanation

8. Were there any discharges of stormwater that had beentemporarily stored or contained? (such as from a pond) YES NO, go to Item E.10

9. Did you collect and analyze samples of temporarily stored orcontained storm water discharges from two storm events?(or one storm event if you checked item D.2.i or iii. above) YES NO, attach explanation

10. Section B.5. of the General Permit requires you to analyze storm water samples for pH, Total Suspended Solids (TSS),Specific Conductance (SC), Total Organic Carbon (TOC) or Oil and Grease (O&G), other pollutants likely to be presentin storm water discharges in significant quantities, and analytical parameters listed in Table D of the General Permit.

a. Does Table D contain any additional parametersrelated to your facility's SIC code(s)? YES NO, Go to Item E.11

b. Did you analyze all storm water samples for theapplicable parameters listed in Table D? YES NO

c. If you did not analyze all storm water samples for theapplicable Table D parameters, check one of thefollowing reasons:

In prior sampling years, the parameter(s) have not been detected in significant quantities from twoconsecutive sampling events. Attach explanation

The parameter(s) is not likely to be present in storm water discharges and authorized non-storm water discharges in significant quantities based upon the facility operator’s evaluation. Attach explanation

Other. Attach explanation

11. For each storm event sampled, attach a copy of the laboratory analytical reports and report the sampling and analysisresults using Form 1 or its equivalent. The following must be provided for each sample collected:

• Date and time of sample collection • Testing results.• Name and title of sampler. • Test methods used.• Parameters tested. • Test detection limits.• Name of analytical testing laboratory. • Date of testing.• Discharge location identification. • Copies of the laboratory analytical results.

03/24/2014

-4-

F. QUARTERLY VISUAL OBSERVATIONS

1. Authorized Non-Storm Water DischargesSection B.3.b of the General Permit requires quarterly visual observations of all authorized non-storm water discharges and their sources.

a. Do authorized non-storm water discharges occur at your facility?

YES NO Go to Item F.2

b. Indicate whether you visually observed all authorized non-storm water discharges and their sources during the quarters when they were discharged. Attach an explanation for any “NO” answers. Indicate “N/A” for quarters without any authorized non-storm water discharges.

July -September YES NO N/A October-December YES NO N/A

January-March YES NO N/A April-June YES NO N/A

c. Use Form 2 to report quarterly visual observations of authorized non-storm water discharges orprovide the following information.

i. name of each authorized non-storm water dischargeii. date and time of observationiii. source and location of each authorized non-storm water dischargeiv. characteristics of the discharge at its source and impacted drainage area/discharge locationv. name, title, and signature of observervi. any new or revised BMPs necessary to reduce or prevent pollutants in authorized non-storm water discharges. Provide new or revised BMP implementation date.

2. Unauthorized Non-Storm Water DischargesSection B.3.a of the General Permit requires quarterly visual observations of all drainage areas to detect the presence of unauthorized non-storm water discharges and their sources.

a. Indicate whether you visually observed all drainage areas to detect the presence of unauthorized non-storm water discharges and their sources. Attach an explanation for any “NO” answers.

July -September YES N/ANO October-December YES NO N/A

January-March YES N/A NO April-June YES NO N/A

b. Based upon the quarterly visual observations, were any unauthorized non-storm water discharges detected?

YES NO Go to item F.2.d

c. Have each of the unauthorized non-storm water discharges been eliminated or permitted?

YES NO Attach explanation

d. Use Form 3 to report quarterly unauthorized non-storm water discharge visual observations or provide the following information.

i. name of each unauthorized non-storm water discharge.ii. date and time of observation.iii. source and location of each unauthorized non-storm water discharge.iv. characteristics of the discharge at its source and impacted drainage area/discharge location.v. name, title, and signature of observer.vi. any corrective actions necessary to eliminate the source of each unauthorized non-storm water

discharge and to clean impacted drainage areas. Provide date unauthorized non-storm water discharge(s) was eliminated or scheduled to be eliminated.

✘ ✘

-5-

G. MONTHLY WET SEASON VISUAL OBSERVATIONS

Section B.4.a of the General Permit requires you to conduct monthly visual observations of storm waterdischarges at all storm water discharge locations during the wet season. These observations shall occur during the first hour of discharge or, in the case of temporarily stored or contained storm water, at the time of discharge.

1. Indicate below whether monthly visual observations of storm water discharges occurred at all discharge locations. Attach an explanation for any “NO” answers. Include in this explanation whether any eligiblestorm events occurred during scheduled facility operating hours that did not result in a storm waterdischarge, and provide the date, time, name and title of the person who observed that there was no stormwater discharge.

YES NO YES NOOctober February

November March

December April

January May

2. Report monthly wet season visual observations using Form 4 or provide the following information.

a. date, time, and location of observationb. name and title of observerc. characteristics of the discharge (i.e., odor, color, etc.) and source of any pollutants observed.d. any new or revised BMPs necessary to reduce or prevent pollutants in storm water discharges.

Provide new or revised BMP implementation date.

ANNUAL COMPREHENSIVE SITE COMPLIANCE EVALUATION (ACSCE)

H. ACSCE CHECKLIST

Section A.9 of the General Permit requires the facility operator to conduct one ACSCE in each reporting period (July 1-June 30). Evaluations must be conducted within 8-16 months of each other. The SWPPP and monitoring programshall be revised and implemented, as necessary, within 90 days of the evaluation. The checklist below includes theminimum steps necessary to complete a ACSCE. Indicate whether you have performed each step below. Attach anexplanation for any “NO” answers.

1. Have you inspected all potential pollutant sources and industrial activities areas? YES NOThe following areas should be inspected:

• areas where spills and leaks have occured during the last year.• outdoor wash and rinse areas.• process/manufacturing areas.• loading, unloading, and transfer areas.• waste storage/disposal areas.• dust/particulate generating areas.• erosion areas.

2. Have you reviewed your SWPPP to assure that its BMPs address existingpotential pollutant sources and industrial activities areas? YES NO

3. Have you inspected the entire facility to verify that the SWPPP’s site map,is up-to-date? The following site map items should be verified: YES NO

• facility boundaries• outline of all storm water drainage areas• areas impacted by run-on

• building repair, remodeling, and construction• material storage areas• vehicle/equipment storage areas• truck parking and access areas• rooftop equipment areas• vehicle fueling/maintenance areas• non-storm water discharge generating areas

• storm water discharges locations• storm water collection and conveyance system• structural control measures such as catch basins,

berms, containment areas, oil/water separators, etc.

-6-

4. Have you reviewed all General Permit compliance records generatedsince the last annual evaluation? YES NO

The following records should be reviewed:

• quarterly authorized non-storm water discharge visual observations• monthly storm water discharge visual observation• records of spills/leaks and associated clean-up/response activities

5. Have you reviewed the major elements of the SWPPP to assurecompliance with the General Permit? YES NO

The following SWPPP items should be reviewed:

• pollution prevention team• list of significant materials• description of potential pollutant sources

6. Have you reviewed your SWPPP to assure that a) the BMPs are adequatein reducing or preventing pollutants in storm water discharges and authorizednon-storm water discharges, and b) the BMPs are being implemented? YES NO

The following BMP categories should be reviewed:

• good housekeeping practices• spill response• employee training• erosion control• quality assurance

7. Has all material handling equipment and equipment needed toimplement the SWPPP been inspected? YES NO

I. ACSCE EVALUATION REPORT

The facility operator is required to provide an evaluation report that includes:

• identification of personnel performing the evaluation• the date(s) of the evaluation• necessary SWPPP revisions

Use Form 5 to report the results of your evaluation or develop an equivalent form.

J. ACSCE CERTIFICATION

The facility operator is required to certify compliance with the Industrial Activities Storm Water General Permit. To certify compliance, both the SWPPP and Monitoring Program must be up to date and be fully implemented.

Based upon your ACSCE, do you certify compliance with the IndustrialActivities Storm Water General Permit? YES NO

If you answered “NO” attach an explanation to the ACSCE Evaluation Report why you are not in compliance with the Industrial Activities Storm Water General Permit.

• quarterly unauthorized non-stormwater discharge visual observations

• Sampling and Analysis records• preventative maintenance inspection

and maintenance records

• preventative maintenance• material handling and storage practices• waste handling/storage• structural BMPs

• assessment of potential pollutant sources• identification and description of the BMPs to be

implemented for each potential pollutant source

• schedule for implementing SWPPP revisions• any incidents of non-compliance and the corrective

actions taken.

-7-

ANNUAL REPORT CERTIFICATION

I am duly authorized to sign reports required by the INDUSTRIAL ACTIVITIES STORM WATER GENERALPERMIT (see Standard Provision C.9) and I certify under penalty of law that this document and all attachmentswere prepared under my direction or supervision in accordance with a system designed to ensure that qualifiedpersonnel properly gather and evaluate the information submitted. Based on my inquiry of the person or personswho manage the system, or those person directly responsible for gathering the information, the informationsubmitted is, to the best of my knowledge and belief, true, accurate and complete. I am aware that there aresignificant penalties for submitting false information, including the possibility of fine and imprisonment forknowing violations.

Printed Name:

Signature: Date:

Title:

Cody Cowgill

Site Engineer

06/30/2014

ANNUAL REPORT

-8-

DESCRIPTION OF BASIC ANALYTICAL PARAMETERS The Industrial Activities Storm Water General Permit (General Permit) requires you to analyze storm water samples for at least four parameters. These are pH, Total Suspended Solids (TSS), Specific Conductance (SC),and Total Organic Carbon (TOC). Oil and Grease (O&G) may be substituted for TOC. In addition, you must monitor for any other pollutants which you believe to be present in your storm water discharge as a result of industrial activity and analytical parameters listed in Table D of the General Permit. There are no numeric limitations for the parameters you test for. The four parameters which the General Permit requires to be tested are considered indicator parameters. In other words, regardless of what type of facility you operate, these parameters are nonspecific and general enough to usually provide some indication whether pollutants are present in your storm water discharge. The following briefly explains what each of these parameters mean: pH is a numeric measure of the hydrogen-ion concentration. The neutral, or acceptable, range is within 6.5 to 8.5. At values less than 6.5, the water is considered acidic; above 8.5 it is considered alkaline or basic. An example of an acidic substance is vinegar, and a alkaline or basic substance is liquid antacid. Pure rainfall tends to have a pH of a little less than 7. There may be sources of materials or industrial activities which could increase or decrease the pH of your storm water discharge. If the pH levels of your storm water discharge are high or low, you should conduct a thorough evaluation of all potential pollutant sources at your site. Total Suspended Solids (TSS) is a measure of the undissolved solids that are present in your storm water discharge. Sources of TSS include sediment from erosion of exposed land, and dirt from impervious (i.e. paved) areas. Sediment by itself can be very toxic to aquatic life because it covers feeding and breeding grounds, and can smother organisms living on the bottom of a water body. Toxic chemicals and other pollutants also adhere to sediment particles. This provides a medium by which toxic or other pollutants end up in our water ways and ultimately in human and aquatic life. TSS levels vary in runoff from undisturbed land. It has been shown that TSS levels increase significantly due to land development. Specific Conductance (SC) is a numerical expression of the ability of the water to carry an electric current. SC can be used to assess the degree of mineralization, salinity, or estimate the total dissolved solids concentration of a water sample. Because of air pollution, most rain water has a SC a little above zero. A high SC could affect the usability of waters for drinking, irrigation, and other commercial or industrial use. Total Organic Carbon (TOC) is a measure of the total organic matter present in water. (All organic matter contains carbon) This test is sensitive and able to detect small concentrations of organic matter. Organic matter is naturally occurring in animals, plants, and man. Organic matter may also be man made (so called synthetic organics). Synthetic organics include pesticides, fuels, solvents, and paints. Natural organic matter utilizes the oxygen in a receiving water to biodegrade. Too much organic matter could place a significant oxygen demand on the water, and possibly impact its quality. Synthetic organics either do not biodegrade or biodegrade very slowly. Synthetic organics are a source of toxic chemicals that can have adverse affects at very low concentrations. Some of these chemicals bioaccumulate in aquatic life. If your levels of TOC are high, you should evaluate all sources of natural or synthetic organics you may use at your site. Oil and Grease (O&G) is a measure of the amount of oil and grease present in your storm water discharge. At very low concentrations, O&G can cause a sheen (that floating "rainbow") on the surface of water (1 qt. of oil can pollute 250,000 gallons of water). O&G can adversely affect aquatic life and create unsightly floating material and film on water, thus making it undrinkable. Sources of O&G include maintenance shops, vehicles, machines and roadways. If you have any questions regarding whether or not your constituent concentrations are too high, please contact your local Regional Board office. The United States Environmental Protection Agency (USEPA) has published stormwater discharge benchmarks for a number of parameters. These benchmarks may be helpful when evaluating whether additional BMPs are appropriate. These benchmarks can be accessed at our website at http://www.swrcb.ca.gov. It is contained in the Sampling and Analysis Reduction Certification.

See Storm Water Contacts at http://www.waterboards.ca.gov/water_issues/programs/stormwater/contact.shtml

2013 2014

2013-2014

ANNUAL REPORTFORM 1 - SAMPLING & ANALYSIS RESULTS

MonitoringLocation

Sample Date/ Time

DischargeTime

SampleCollector

Name, Title

Parameter Result Units AnalyticalMethod

MethodDetection

Limit

Analyzed By

Outfall001 02/28/201414:10

14:10 MosesRomero, GasTechnician

Total OrganicCarbon(TOC)

=17 mg/L A5310B 110 LAB

Outfall001 02/28/201414:10

14:10 MosesRomero, GasTechnician

Total OrganicCarbon(TOC)

=17 mg/L A5310B 110 LAB

Outfall001 02/28/201414:10

14:10 MosesRomero, GasTechnician

Iron, Total =790 mg/L E200.7 1 LAB

Outfall001 02/28/201414:10

14:10 MosesRomero, GasTechnician

ElectricalConductivity@ 25 Deg. C

=540 umhos/cm A2510B 200 LAB

Outfall001 02/28/201414:10

14:10 MosesRomero, GasTechnician

Oil andGrease

=0 mg/L E1664A 15 LAB

Outfall001 02/28/201414:10

14:10 MosesRomero, GasTechnician

pH =8.37 SU A4500H 9 LAB

Outfall001 02/28/201414:10

14:10 MosesRomero, GasTechnician

TotalSuspendedSolids (TSS)

=26000 mg/L A2540D 100 LAB

Outfall B 02/28/201413:00

13:00 MosesRomero, GasTechnician

Total OrganicCarbon(TOC)

=4.2 mg/L A5310B 110 LAB

Outfall B 02/28/201413:00

13:00 MosesRomero, GasTechnician

Total OrganicCarbon(TOC)

=4.1 mg/L A5310B 110 LAB

Outfall B 02/28/201413:00

13:00 MosesRomero, GasTechnician

Iron, Total =65 mg/L E200.7 1 LAB

Outfall B 02/28/201413:00

13:00 MosesRomero, GasTechnician

ElectricalConductivity@ 25 Deg. C

=190 umhos/cm A2510B 200 LAB

Outfall B 02/28/201413:00

13:00 MosesRomero, GasTechnician

Oil andGrease

=3.2 mg/L E1664A 15 LAB

Outfall B 02/28/201413:00

13:00 MosesRomero, GasTechnician

pH =8.6 SU A4500H 9 LAB

Outfall B 02/28/201413:00

13:00 MosesRomero, GasTechnician

TotalSuspendedSolids (TSS)

=1800 mg/L A2540D 100 LAB

Outfall North 02/28/201413:40

13:40 MosesRomero, GasTechnician

Total OrganicCarbon(TOC)

=8 mg/L A5310B 110 LAB

Outfall North 02/28/201413:40

13:40 MosesRomero, GasTechnician

Total OrganicCarbon(TOC)

=8.3 mg/L A5310B 110 LAB

Outfall North 02/28/201413:40

13:40 MosesRomero, GasTechnician

Iron, Total =12 mg/L E200.7 1 LAB

Outfall North 02/28/201413:40

13:40 MosesRomero, GasTechnician

ElectricalConductivity@ 25 Deg. C

=500 umhos/cm A2510B 200 LAB

Outfall North 02/28/201413:40

13:40 MosesRomero, GasTechnician

Oil andGrease

=0 mg/L E1664A 15 LAB

Outfall North 02/28/201413:40

13:40 MosesRomero, GasTechnician

pH =7.64 SU A4500H 9 LAB

Outfall North 02/28/201413:40

13:40 MosesRomero, GasTechnician

TotalSuspendedSolids (TSS)

=240 mg/L A2540D 100 LAB

2013-2014

ANNUAL REPORTFORM 2 - QUARTERLY VISUAL OBSERVATIONS OF AUTHORIZED

NON-STORM WATER DISCHARGES (NSWDs)

Quarter Date/Time(HH:MM) Observer Name Observer Title Any Authorized NSWDsThis Quarter?

July - Sept 09/25/2013 Moses Romero Gas Technician No

Source and Location ofAuthorized NSWD

Name of AuthorizedNSWD

Authorized NSWDCharacteristics at Source

Authorized NSWDCharacteristics atDrainage Area andDischarge Location

Revised or New BMPsDescription and

Implementation Date

Quarter Date/Time(HH:MM) Observer Name Observer Title Any Authorized NSWDsThis Quarter?

Oct - Dec 11/21/2013 Moses Romero Gas Technician No

Source and Location ofAuthorized NSWD

Name of AuthorizedNSWD

Authorized NSWDCharacteristics at Source

Authorized NSWDCharacteristics atDrainage Area andDischarge Location

Revised or New BMPsDescription and

Implementation Date

Quarter Date/Time(HH:MM) Observer Name Observer Title Any Authorized NSWDsThis Quarter?

Jan - Mar 02/26/2014 Moses Romero Gas Technician No

Source and Location ofAuthorized NSWD

Name of AuthorizedNSWD

Authorized NSWDCharacteristics at Source

Authorized NSWDCharacteristics atDrainage Area andDischarge Location

Revised or New BMPsDescription and

Implementation Date

Quarter Date/Time(HH:MM) Observer Name Observer Title Any Authorized NSWDsThis Quarter?

Apr - Jun 05/21/2014 Moses Romero Gas Technician No

Source and Location ofAuthorized NSWD

Name of AuthorizedNSWD

Authorized NSWDCharacteristics at Source

Authorized NSWDCharacteristics atDrainage Area andDischarge Location

Revised or New BMPsDescription and

Implementation Date

2013-2014

ANNUAL REPORTFORM 3 - QUARTERLY VISUAL OBSERVATIONS OF UNAUTHORIZED

NON-STORM WATER DISCHARGES (NSWDs)

Quarter Date/Time(HH:MM) Observer Name Observer Title Unauthorized NSWDsObserved?

Indications of PriorUnauthorized

NSWDs?

July - Sept 09/25/2013 00:00 Moses Romero Gas Technician No No

Source and Location ofUnauthorized NSWD

Name of UnauthorizedNSWD

Unauthorized NSWDCharacteristics at Source

Unauthorized NSWDCharacteristics atDrainage Area andDischarge Location

Corrective Actions toEliminate UnauthorizedNSWD and Elimination

Date

Quarter Date/Time(HH:MM) Observer Name Observer Title Unauthorized NSWDsObserved?

Indications of PriorUnauthorized

NSWDs?

Oct - Dec 11/21/2013 00:00 Moses Romero Gas Technician No No

Source and Location ofUnauthorized NSWD

Name of UnauthorizedNSWD

Unauthorized NSWDCharacteristics at Source

Unauthorized NSWDCharacteristics atDrainage Area andDischarge Location

Corrective Actions toEliminate UnauthorizedNSWD and Elimination

Date

Quarter Date/Time(HH:MM) Observer Name Observer Title Unauthorized NSWDsObserved?

Indications of PriorUnauthorized

NSWDs?

Jan - Mar 02/26/2014 00:00 Moses Romero Gas Technician No No

Source and Location ofUnauthorized NSWD

Name of UnauthorizedNSWD

Unauthorized NSWDCharacteristics at Source

Unauthorized NSWDCharacteristics atDrainage Area andDischarge Location

Corrective Actions toEliminate UnauthorizedNSWD and Elimination

Date

Quarter Date/Time(HH:MM) Observer Name Observer Title Unauthorized NSWDsObserved?

Indications of PriorUnauthorized

NSWDs?

Apr - Jun 05/21/2014 00:00 Moses Romero Gas Technician No No

Source and Location ofUnauthorized NSWD

Name of UnauthorizedNSWD

Unauthorized NSWDCharacteristics at Source

Unauthorized NSWDCharacteristics atDrainage Area andDischarge Location

Corrective Actions toEliminate UnauthorizedNSWD and Elimination

Date

2013-2014

ANNUAL REPORTFORM 4 - MONTHLY VISUAL OBSERVATIONS OF

STORM WATER DISCHARGES

ObservationDate:

ObserverName:

ObserverTitle:

LocationDescription

ObservationTime

TimeDischarge

Began

WerePollutantsObserved?

DrainageArea

Description

DescribeStorm WaterDischarge

Characteristics

Identify andDescribe

Source(s) ofPollutants

Describe anyRevised orNew BMPsand Their

Date ofImplementati

on

ObservationDate:

ObserverName:

ObserverTitle:

LocationDescription

ObservationTime

TimeDischarge

Began

WerePollutantsObserved?

DrainageArea

Description

DescribeStorm WaterDischarge

Characteristics

Identify andDescribe

Source(s) ofPollutants

Describe anyRevised orNew BMPsand Their

Date ofImplementati

on

ObservationDate:

ObserverName:

ObserverTitle:

LocationDescription

ObservationTime

TimeDischarge

Began

WerePollutantsObserved?

DrainageArea

Description

DescribeStorm WaterDischarge

Characteristics

Identify andDescribe

Source(s) ofPollutants

Describe anyRevised orNew BMPsand Their

Date ofImplementati

on

ObservationDate:

ObserverName:

ObserverTitle:

LocationDescription

ObservationTime

TimeDischarge

Began

WerePollutantsObserved?

DrainageArea

Description

DescribeStorm WaterDischarge

Characteristics

Identify andDescribe

Source(s) ofPollutants

Describe anyRevised orNew BMPsand Their

Date ofImplementati

on

ObservationDate:

02/28/201400:00

ObserverName:

MosesRomero

ObserverTitle:

GasTechnician

LocationDescription

ObservationTime

TimeDischarge

Began

WerePollutantsObserved?

DrainageArea

Description

DescribeStorm WaterDischarge

Characteristics

Identify andDescribe

Source(s) ofPollutants

Describe anyRevised orNew BMPsand Their

Date ofImplementati

on

DrainageLocation1

Outfall001 14:00 14:10 Yes Dischargefrom sediment

basin.

Cloudydiscolored

liquids.

Can not beidentified.

UpstreamBMPs of strawwattles around

all surfacewater inlets willbe installed by

October 1,2014.

Structuralimprovementsand cleanoutof stormwater

basin toincreasepollutantremoval

effectivenesswill be done as

soon aspermits allow.

DrainageLocation2

Outfall North 13:30 13:10 Yes Dischargefrom sediment

basin.

Cloudydiscolored

liquids.

Can not beidentified.

UpstreamBMPs of strawwattles around

all surfacewater inlets willbe installed by

October 1,2014.

Cleanout ofstormwater

basin toincreasepollutantremoval

effectivenesswill be done as

soon aspermits allow.

DrainageLocation3

Outfall B 12:50 12:50 Yes Dischargefrom side

slope of opendirt lot.

Cloudydiscolored

liquids.

Can not beidentified.

UpstreamBMPs of strawwattles around

all surfacewater inlets willbe installed by

October 1,2014.

ObservationDate:

ObserverName:

ObserverTitle:

LocationDescription

ObservationTime

TimeDischarge

Began

WerePollutantsObserved?

DrainageArea

Description

DescribeStorm WaterDischarge

Characteristics

Identify andDescribe

Source(s) ofPollutants

Describe anyRevised orNew BMPsand Their

Date ofImplementati

on

ObservationDate:

ObserverName:

ObserverTitle:

LocationDescription

ObservationTime

TimeDischarge

Began

WerePollutantsObserved?

DrainageArea

Description

DescribeStorm WaterDischarge

Characteristics

Identify andDescribe

Source(s) ofPollutants

Describe anyRevised orNew BMPsand Their

Date ofImplementati

on

ObservationDate:

ObserverName:

ObserverTitle:

LocationDescription

ObservationTime

TimeDischarge

Began

WerePollutantsObserved?

DrainageArea

Description

DescribeStorm WaterDischarge

Characteristics

Identify andDescribe

Source(s) ofPollutants

Describe anyRevised orNew BMPsand Their

Date ofImplementati

on

2013-2014

ANNUAL REPORTFORM 5 - ANNUAL COMPREHENSIVE SITE COMPLIANCE EVALUATION

POTENTIAL POLLUTANT SOURCE/INDUSTRIAL ACTIVITY BMP STATUS

Evaluation Date: 06/19/2014 Inspector Name: Cody Cowgill Title: Site Engineer

Potential PollutantSource/Industrial Activity

Area

Are any BMPs Not FullyImplemented?

Are Additional/RevisedBMPs Necessary?

Deficiencies in BMPs orBMP implementation

Additional/Revised BMPsor Corrective Actions and

their date(s) ofImplementation

Landfilling Operations Yes Yes Sediment control fromlandfill outside slopes may

not be adequate and basinsmay need structural

improvements and/ormaintenance to be more

effective.

Upstream BMPs of strawwattles around all surface

water inlets will be installedby October 1, 2014.

Structural improvementsand/or cleanout of

stormwater basins toincrease pollutant removaleffectiveness will be doneas soon as permits allow.

Fueling Area No No

Other Areas (AccessRoads)

No No

Maintenance Shop No No

New Construction Yes No Sediment control fromoutside slopes may not be

adequate.

Upstream BMPs of strawwattles around all surface

water inlets will be installedby October 1, 2014.

Flare Station and Gas Plant No No

Liquid Handling No No

Recycle Reload No No

2013-2014

ANNUAL REPORTEXPLANATIONS SPECIFIED FOR VARIOUS YES/NO QUESTIONS IN THE REPORT

Attachments:

Explanation Question Explanation Text

E1 Only one rain event resulted in enough rainfall to cause a discharge.

E5 Stormwater discharge points that are not monitored are considered to be equivalent to dischargepoints that are monitored. The description of the discharge points include areas adjacent toOutfall A and Outfall B, which are open dirt lots. These drainage areas are identical in land useand characteristics and support the use of representative outfalls as substantially identical tothose that are not sampled. The description of the discharge points also include areasrepresented by Outfall003, which is the main access road. These drainage areas are identical inland use and characteristics and support the use of representative outfalls as substantiallyidentical to those that are not sampled.

G .October No rain event resulted in enough rainfall to cause a discharge. Each discharge point wasobserved by Moses Romero, Gas Technician, during each rain event and the observation wasrecorded. 10/22/13 rainfall did not result in a discharge.

G .November No rain event resulted in enough rainfall to cause a discharge. Each discharge point wasobserved by Moses Romero, Gas Technician, during each rain event and the observation wasrecorded. 11/20/13 rainfall did not result in a discharge.

G .December No rain event resulted in enough rainfall to cause a discharge. Each discharge point wasobserved by Moses Romero, Gas Technician, during each rain event and the observation wasrecorded. 12/18/13 rainfall did not result in a discharge.

G .January No rain event resulted in enough rainfall to cause a discharge. Each discharge point wasobserved by Moses Romero, Gas Technician, during each rain event and the observation wasrecorded. 1/29/14 rainfall did not result in a discharge.

G .March No rain event resulted in enough rainfall to cause a discharge. Each discharge point wasobserved by Moses Romero, Gas Technician, during each rain event and the observation wasrecorded. 3/26/14 rainfall did not result in a discharge.

G .April No rain event resulted in enough rainfall to cause a discharge. Each discharge point wasobserved by Moses Romero, Gas Technician, during each rain event and the observation wasrecorded. 4/23/14 rainfall did not result in a discharge.

G .May No rain event resulted in enough rainfall to cause a discharge. Each discharge point wasobserved by Moses Romero, Gas Technician, during each rain event and the observation wasrecorded. 5/20/14 rainfall did not result in a discharge.

Attachment Title Description Date Uploaded Attachment Type Attachment Hash Doc Part No/TotalParts

Laboratory Results 06/20/2014 Laboratory Results 4dee616f96853eea55186bcc6d58a868b79791a2f6923f54349a0de2b2af

1/1

W-3 Storm Water Pollution Prevention Plan (SWPPP)

STORMWATER POLLUTION PREVENTION PLAN

Waste Management El Sobrante Landfill Facility Prepared For: El Sobrante Landfill 10910 Dawson Canyon Road Corona, California 92883 Prepared By: Golder Associates Inc. 1000 Enterprise Drive, Suite 100 Roseville, CA 95678

December 2014

SWPP

P

Golder, Golder Associates and the GA globe design are trademarks of Golder Associates Corporation

A world ofcapabilities

delivered locally

December 2014 i Project No. 14-05406-20

Stormwater Pollution Prevention Plan (SWPPP)

Project Information and Certification

September 2014 State Water Resources Control Board Water Quality Order No. 2014-0057-DWQ

NPDES General Permit No. CAS000001 (Waste Discharge Requirements for Discharges of Stormwater Associated with Industrial Activities)

Project Information Prepared for: Waste Management - El Sobrante Landfill 10910 Dawson Canyon Road Corona, CA 92883 Contact: David Harich, District Manager (951) 277-5103

WDID: 8 33I000559 SIC Code: 4953 Refuse Systems Site Area Approximately 1,407 acres Impervious Area (%) Impervious (99%) with the exception of paved access roads. Receiving Water Dawson Creek, Temescal Wash

Reviewing Agency Jurisdiction: Regional Water Quality Control Board, Santa Ana Region

3737 Main Street, Suite 500

Riverside, CA 92501-3348 Phone: (951) 782-4130 Fax: (951) 781-6288

Contacts: Cody Cowgill (951) 415-4194

Project Engineer Prepared by: Golder Associates, Inc. 1000 Enterprise Way, Suite 100 Roseville, CA 95678 (916) 786-2424 (916) 786-2434 (fax) Contact: Ed Childers, P.E. Project Number: 14-05406-20

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 ii Project No. 14-05406-20

Plan Certification

I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to ensure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, to the best of my knowledge and belief, the information submitted is, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.

_________________________________ ________________________________ David Harich, District Manager Date Waste Management. El Sobrante Landfill Facility

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 iii Project No. 14-05406-20

Record of Revisions

Revision Number Prepared by Description of Revision Date of Revision

Rev 0 Original Issue Golder All December 2014

Future SWPPP addenda with Additional/Revised BMPs are included in Appendix A

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 iv Project No. 14-05406-20

Acronyms

ACSCE Annual Comprehensive Facility Compliance Evaluation

ASTM American Society for Testing and Materials

AST Aboveground Storage Tank

BMP Best Management Practice

CASQA California Stormwater Quality Association

CFR Code of Federal Regulations

DI Drain Inlet

ERA Exceedance Response Actions

HMBP Hazardous Material Business Plan

LRP Legally Responsible Person

NOI Notice of Intent

NPDES National Pollutant Discharge Elimination System

NSWD Non-Stormwater Discharge

O&G Total Oil and Grease

PPT Pollution Prevention Team

QA/QC Quality Assurance and Quality Control

QISP Qualified Industrial Stormwater Practitioner

QSE Qualifying Storm Event

RP Responsible Person

SARA Superfund Amendments and Reauthorization Act

SARWQCB Santa Ana Regional Water Quality Control Board

SIC Standard Industrial Classification

SM Standard Methods for the Examination of Water and Wastewater

SMARTs Stormwater Multiple Application and Report Tracking System

SPCC Spill Prevention Control and Countermeasures

SWPPP Stormwater Pollution Prevention Plan

SWRCB California State Water Resources Control Board

TSS Total Suspended Solids

USEPA United States Environmental Protection Agency

WDR Waste Discharge Requirements

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 v Project No. 14-05406-20

Table of Contents 1.0 INTRODUCTION ............................................................................................................................... 1 2.0 STORMWATER PLANNING AND ORGANIZATION ........................................................................ 2

2.1.1 Responsible Person and Alternate .......................................................................................... 2 2.1.2 PPT Composition and Responsibilities .................................................................................... 2

3.0 FACILITY DESCRIPTION ................................................................................................................. 4 3.1 Facility General Characteristics ................................................................................................... 4 3.2 Site Layout ................................................................................................................................... 4 3.3 Site Drainage Areas, Flow, and Drain Inlet Locations ................................................................. 5 3.4 Receiving Waters ......................................................................................................................... 6

4.0 POTENTIAL POLLUTANT SOURCES and POLLUTANTS ............................................................. 7 4.1 Material Handling and Storage Areas .......................................................................................... 7

4.1.1 Materials Inventory ................................................................................................................... 8 4.1.2 Material Receiving ................................................................................................................... 8 4.1.3 Material Storage & Handling .................................................................................................... 8 4.1.4 Material Shipping ..................................................................................................................... 9

4.2 Industrial Processes ..................................................................................................................... 9 4.2.1 Equipment Maintenance and Fueling ...................................................................................... 9 4.2.2 Gas Collection System ............................................................................................................. 9

4.3 Dust and Particulate Generating Activities ................................................................................. 10 4.4 Significant Spills and Leaks ....................................................................................................... 10 4.5 Non-Stormwater Discharges ...................................................................................................... 10 4.6 Erodible Surfaces ....................................................................................................................... 11 4.7 Pollutant Source Assessment .................................................................................................... 11

5.0 MINIMUM BMPS ............................................................................................................................. 12 5.1 Good Housekeeping .................................................................................................................. 12 5.2 Preventative Maintenance .......................................................................................................... 13 5.3 Spill and Leak, Prevention and Response ................................................................................. 13 5.4 Material Handling and Waste Management ............................................................................... 14 5.5 Erosion and Sediment Control ................................................................................................... 15 5.6 Employee Training Program ...................................................................................................... 15 5.7 Quality Assurance and Record Keeping .................................................................................... 16 5.8 Minimum BMP Exceptions ......................................................................................................... 16

6.0 ADVANCED BMPS ......................................................................................................................... 17 6.1 Exposure Minimization ............................................................................................................... 17 6.2 Stormwater Containment and Discharge Reduction BMPs ....................................................... 17

6.2.1 Contaminated Soil Acceptance BMPs ................................................................................... 17 6.2.2 Sedimentation Basins ............................................................................................................ 17

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 vi Project No. 14-05406-20

6.2.3 Down Drain Maintenance ....................................................................................................... 18

6.3 Treatment Control BMPs ............................................................................................................ 18 6.4 Other Advanced BMPs ............................................................................................................... 18

6.4.1 Secondary Containment ........................................................................................................ 18 6.4.2 Hydrojetting ............................................................................................................................ 18 6.4.3 Track-out Prevention .............................................................................................................. 19 6.4.4 Erosion Control ...................................................................................................................... 19

6.4.4.1 Scheduling ......................................................................................................................... 19 6.4.4.2 Preservation of Existing Vegetation ................................................................................... 20 6.4.4.3 Seeding .............................................................................................................................. 20 6.4.4.4 Geotextile and Mats ........................................................................................................... 20 6.4.4.5 Slope Protection ................................................................................................................. 20 6.4.4.6 Non-vegetative stabilization ............................................................................................... 20 6.4.4.7 Soil Binders ........................................................................................................................ 20

6.4.5 Sediment Control ................................................................................................................... 20 6.4.5.1 Fiber Rolls (straw wattles or Filtrexx Soxx®) ...................................................................... 21 6.4.5.2 Sweeping ........................................................................................................................... 21 6.4.5.3 Storm Drain Inlet Protection (within hardscape areas) ...................................................... 21

7.0 TEMPORARY SUSPENSION OF INDUSTRIAL ACTIVITIES ....................................................... 22 8.0 MONITORING IMPLEMENTATION PLAN (MIP) ........................................................................... 23

8.1 Discharge Locations ................................................................................................................... 23 8.2 Visual Observations ................................................................................................................... 23

8.2.1 Monthly Visual Observations ................................................................................................. 24 8.2.2 Sampling Event Visual Observations ..................................................................................... 24 8.2.3 Visual Observation Records and Response Procedures ...................................................... 25

8.3 Sampling and Analysis ............................................................................................................... 26 8.4 Parameters for Analysis, Methods, Detection Limits, and USEPA Benchmark values ............. 27

8.4.1 Sector Required Analysis ....................................................................................................... 27 8.4.1.1 SIC Code 4953 ................................................................................................................... 27

8.5 Sample Collection and Handling Procedure .............................................................................. 27 8.5.1 Field Calibration Procedures .................................................................................................. 28

8.6 Monitoring Methods and Exceptions .......................................................................................... 28 8.7 NALs and NAL Exceedances ..................................................................................................... 28

8.7.1 Annual NAL exceedance ....................................................................................................... 28 8.7.2 Instantaneous maximum NAL exceedance ........................................................................... 29

8.8 Exceedance Response Actions ................................................................................................. 29 8.8.1 Baseline Status ...................................................................................................................... 29 8.8.2 Level 1 Status ........................................................................................................................ 29

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 vii Project No. 14-05406-20

8.8.2.1 Level 1 ERA Evaluation ..................................................................................................... 29 8.8.2.2 Level 1 ERA Report ........................................................................................................... 29 8.8.2.3 NAL Exceedances Prior to Implementation of Level 1 Status BMPs. ............................... 30

8.8.3 Level 2 Status ........................................................................................................................ 30 8.8.3.1 Level 2 ERA Action Plan .................................................................................................... 30 8.8.3.2 Level 2 ERA Technical Report ........................................................................................... 31 8.8.3.3 Level 2 ERA Technical Report Submittal ........................................................................... 32 8.8.3.4 Eligibility for Returning to Baseline Status ......................................................................... 33 8.8.3.5 Level 2 ERA Implementation Extension ............................................................................. 33

8.9 Annual Comprehensive Facility Compliance Evaluation (Annual Evaluation) ........................... 34 8.10 PPT Member Assignments ........................................................................................................ 34

9.0 MONITORING RECORDS AND REPORTING REQUIREMENTS ................................................ 35 9.1 Record Keeping ......................................................................................................................... 35 9.2 Reporting Requirements ............................................................................................................ 35

10.0 References ...................................................................................................................................... 36 List of Tables Table 1 Facility Pollution Prevention Team (PPT) Table 2 List of Industrial Materials Table 3 BMP Summary Table 4 Test Parameters, Methods, Detection Limits, and Industrial Benchmarks for SW-1, SW-2,

and SW-3

List of Figures Figure 1 Regional Setting Figure 2 Site Vicinity Figure 3 Site Map Figure 4 Maintenance area Figure 5 Site Entrance area List of Appendices Appendix A Future SWPPP addenda with Additional/Revised BMPs Appendix B SWRCB WQO No. 2014-0057-DWQ, NPDES General Permit No. CAS000001, WDRs for

Discharges of Stormwater Associated with Industrial Activities (Inclusive of submitted NOI)

Appendix C California 2010 Integrated Report (303(d) List/305(b) Report for Loma Alta Creek Appendix D Employee Training Records and Training Documentation Appendix E Spill Response Procedures, Spill Guide, List of Significant Spills and Leaks Appendix F Example Stormwater Monitoring and Reporting Forms Appendix G California Stormwater Quality Association (CASQA) BMP Handbook Fact Sheets Appendix H Industrial Stormwater Monitoring and Sampling Guide (EPA 832-B-09-003) Appendix I Program Compliance Documentation (Bound Separately)

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 1 Project No. 14-05406-20

1.0 INTRODUCTION Golder Associates, Inc. (Golder) has prepared this Stormwater Pollution Prevention Plan (SWPPP) for the

El Sobrante Landfill Facility (the Facility). The Facility is located at 10910 Dawson Canyon Road, Corona,

California 92883. The Facility is categorized under Standard Industrial Classification (SIC) code 4953,

Refuse Systems. This SWPPP provides site information and Best Management Practices (BMPs) to meet

the requirements of the State Water Resources Control Board (SWRCB) General Permit for Industrial

Stormwater Discharges; SWRCB WQO No. 2014-0057-DWQ, NPDES General Permit No. CAS000001,

WDRs for Discharges of Stormwater Associated with Industrial Activities (General Permit, Appendix A).

This SWPPP provides information regarding the pollution prevention team for the Facility and Facility

details in Sections 2 and 3; provides a pollutant source assessment in Sections 4 and associated Best

Management Practices (BMPs) in Sections 5 and 6; a discussion of Temporary Suspension of Industrial

Activities in Section 7; and a Monitoring Implementation Plan (MIP) in Section 8. The content is consistent

with the requirements of the General Permit. The purpose of the SWPPP is to protect surface water

quality by reducing the amount of pollutants in stormwater runoff.

The SWPPP has two major objectives:

To identify and evaluate sources of pollutants associated with industrial activities that may affect the quality of stormwater discharges and authorized non-stormwater discharges from the facility; and

To identify and describe minimum and site-specific advanced BMPs implemented to reduce or prevent pollutants associated with industrial activities in stormwater discharges and authorized non-stormwater discharges in a manner that reflects best industry practice considering technological availability and economic practicability and achievability.

This SWPPP is a public domain document and is required to be certified and submitted to the SWRCB

Storm Water Multiple Application and Report Tracking System (SMARTS).

Preparation of this SWPPP does not guarantee compliance with the General Permit. It is the responsibility

of El Sobrante Landfill to implement the BMPs, MIP, and recommendations set forth in this document and

revise the SWPPP when conditions warrant. When the SWPPP contains significant revisions (i.e. new

industrial activity or pollutant source), the General Permit requires that it be certified and re-submitted to

SMARTS within 30 days. Less than significant revisions are required to be certified and submitted to

SMARTS at least every three (3) months.

This SWPPP has been prepared by Golder for the exclusive use of Waste Management and El Sobrante

Landfill. Golder prepared this SWPPP based upon information provided by Waste Management and El

Sobrante Landfill and the site visit conducted by Golder on August 4, 2014.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 2 Project No. 14-05406-20

2.0 STORMWATER PLANNING AND ORGANIZATION This section of the SWPPP identifies specific positions or individuals that comprise the El Sobrante

Landfill Pollution Prevention Team (PPT) that are responsible for implementing the SWPPP and General

Permit requirements.

The Facility’s District Manager and Site Engineer oversee the implementation of this SWPPP and

coordinate the activities of the PPT. The PPT assists the District Manager and Site Engineer implement

the SWPPP, identify necessary SWPPP revisions, and conduct required monitoring activities. The El

Sobrante Landfill PPT is further described in the following sections.

2.1.1 Responsible Person and Alternate The District Manager is the Responsible Person (RP) for stormwater pollution prevention at his facility and

is responsible for:

Oversight of SWPPP development

Oversight of implementation and revision of the SWPPP

Oversight of implementation of the monitoring program activities required in the General Permit, Section B, and described in the MIP in this SWPPP

Reviewing the Annual Comprehensive Facility Compliance Evaluation

Reviewing and certifying submittals and Annual Reports

Allocating adequate resources to SWPPP implementation

Seeking adequate capital investment budget for BMP implementation consistent with technological availability and economic practicability and achievability as necessary

The Site Engineer will be the alternate RP in the absence of the District Manager.

2.1.2 PPT Composition and Responsibilities The PPT is comprised of several key individuals as shown in Table 1. Each member is listed in the table

as his/her job title and responsibilities. The PPT is responsible for:

Implementing the SWPPP.

Implementation of monitoring program activities described in the MIP in this SWPPP

Conducting sampling, monthly and sample event visual observations, operations and maintenance, and responding to emergency situations

Arranging for training of all team members and other personnel as necessary in General Permit requirements, operation, maintenance and inspections of BMPs, BMP effectiveness evaluations, and monitoring activities

Conducting good housekeeping and preventative maintenance observations of the facility.

Identifying and directing corrective action for any spills, leaks or other potential sources of pollutants

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 3 Project No. 14-05406-20

Completing the Annual Comprehensive Facility Compliance Evaluation

Completing submittals and Annual Reports

Reviewing the SWPPP annually and revising the SWPPP as necessary

The RP will assign an alternate team member based on training, qualifications, and availability in the

event of a temporary absence of a member of the PPT. A Qualified Industrial Storm Water Practitioner

(QISP) is not currently required for this Facility. However, in the event that the Facility enters a Level 1

Exceedance Response Actions (ERA) status, the RP will engage a QISP who has completed a SWRCB-

sponsored or approved training course or a self-guided course for licensed professionals.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 4 Project No. 14-05406-20

3.0 FACILITY DESCRIPTION

3.1 Facility General Characteristics The El Sobrante Landfill facility is located at 10910 Dawson Canyon Road in the City of Corona, Riverside

County, California 92883. The Facility is a Class III landfill comprising approximately 1,407 acres of land.

The receiving water for the Facility is Dawson Creek and Temescal Wash.

3.2 Site Layout The figures in this SWPPP include information describing the relevant physical features, structures and

impervious areas, stormwater collection and conveyance systems, and locations of structural control

measures that affect industrial stormwater discharges. The figures also include information for identifying

potential threats to stormwater quality. Figure 1 shows the regional setting of the Facility. Figure 2 shows

the site vicinity and nearby water bodies. Figure 3 shows the facility boundaries, drainage areas, points of

stormwater discharge, structural control measures, impervious areas, and areas of industrial activities.

The facility includes several trailers used for administrative activities and a maintenance building. The

administrative trailers are located near the Facility entrance on the southern portion of the site. A guard

building is located at the Facility entrance. The maintenance building is located on the northern portion of

the Facility and is approximately 5,000 square feet. The northeastern portion of the Facility is permitted

for future expansion phases, but is currently undeveloped with the exception of a limited area of new cell

construction.

There is a closed mining area (USA Waste of CA Tile No. 6) pending agency response on reclamation of

the southern portion of the property. Industrial activities do not occur in this area and therefore the area is

not required to be covered in this SWPPP.

An area leased to Rentrac is located on the southwestern portion of the property. Rentrac is the operator

of this area and is responsible for implementation of the BMPs included in this SWPPP. Additionally,

Rentrac is the operator (various stockpiled materials) of the clay mine area on the west.

Properties to the north and east are undeveloped. Properties to the southeast are undeveloped followed

by residences and Dawson Creek. Properties to the south and west are undeveloped followed by

industrially developed properties. Dawson Creek is located approximately 400 feet south of the Facility

and was dry at the time of the site visit.

Dawson Canyon Road located to the southwest of the site provides access to the Facility.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 5 Project No. 14-05406-20

3.3 Site Drainage Areas, Flow, and Drain Inlet Locations In general, storm water run-off is collected and conveyed in control ditches, sideslope benches, and

down-drain pipes. Additionally, several sedimentation basins or traps are located at the Facility to reduce

sediment-laden run-off.

Surface water flow patterns, drain inlet locations, site drainage areas, and the site stormwater discharge

points are shown on Figure 3. Stormwater discharges off-site from seven outfall locations at the Facility.

The outfall locations are designated as Outfall 001, 002, 003, North, South, Outfall A, and Outfall B.

Drainage and erosion are controlled at the El Sobrante Landfill by using an engineered and designed

series of ditches, benches, down-drain pipes, and sediment basins. The ditches and benches generally

collect runoff and convey it to down-drain pipes or chutes. These pipes convey the storm water off the

landfill surface. Most of the Facility drains to the south, into the South Runoff Control Channel and flows

to a sediment basin and ultimately to Outfall 001.

Outfall North is located on the northern side of the facility and discharges water from Sediment Basin 1.

Stormwater from the bone yard and unpaved road on the northern portion of the Facility flows to

Sediment Basin 1.

Outfall 002 is located on the northwestern portion of the Facility and collects the stormwater discharge

from Sediment Basin 2. Sediment Basin 2 collects stormwater from the access road, maintenance shop

and undeveloped slopes and landfill slopes. Stormwater from the maintenance area flows to Outfall 002

via an earthen and concrete berm.

Stormwater from the active landfill on the southeastern portion of the Facility discharges to Outfall South

located to the southeast of the Facility. The stormwater flows to a detention basin which is connected to a

culvert. If there is a significant amount of stormwater, the stormwater discharges to Dawson Creek

located south of the culvert.

Outfall 001 is located on the southern portion of the facility. Stormwater from Sediment Basin 3

discharges to Outfall 1. Stormwater from the curbside recycling and landfill areas flows to Sediment

Basin 3.

Outfall 003 is located on the southern portion of the Facility and collects stormwater from the main access

road.

Stormwater from the Rentrac and clay mine deck area on the western portion of the facility flow to a

sediment basin on the eastern portion of the Rentrac lease area and is the conveyed to a discharge point

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 6 Project No. 14-05406-20

located West of the main access road, which is Outfall A. Stormwater from the slopes adjacent to and the

access road associated with the Rentrac lease area discharge to Outfall B.

3.4 Receiving Waters The Facility discharges to unnamed tributaries and Dawson Creek which flow to Temscal Wash.

Temescal Wash is located approximately 0.25 miles to the southwest of the Facility and discharges to the

Santa Ana River.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 7 Project No. 14-05406-20

4.0 POTENTIAL POLLUTANT SOURCES AND POLLUTANTS The Facility is a Class III Landfill facility operated by Waste Management and accepts solid wastes,

source-separated recyclable materials (SSRM), and approved special wastes. The eastern portion of the

Facility is the landfill area where waste is disposed and recyclables are stored. A portion of the western

side of the Facility is a clay mine which is leased to an equipment rental business (Rentrac) who stores

equipment and vehicles in the area and operates stockpiles of mining materials.

The operating hours of the facility are Monday to Saturday 6 AM to 6 PM, excluding holidays.

The primary potential sources of pollutants at the Facility include industrial processes and industrial

materials. Additional potential sources include:

Dust and Particulate Generating Activities;

Significant Spills and Leaks; and

Non-Stormwater Discharges.

Maintenance Activities

Fueling Activities

Gas Plant

Flare Station

Liquids Handling Tank Farm

Table 2 lists industrial materials used on-site that could be potential stormwater pollutants. The table

provides a description of quantities, characteristics, receiving, shipping, storage and handling areas,

storage methods, and containment measures, and likelihood of contact with stormwater.

Table 3 describes industrial activities, potential pollutant sources, and potential pollutants. In addition,

Table 3 describes the BMPs that are implemented to address the activities, sources, and pollutants. The

locations of industrial materials that could potentially be exposed to stormwater at the Facility are shown

on Figure 3.

Facility specific industrial processes and industrial materials are further described in the subsections

below.

4.1 Material Handling and Storage Areas The industrial materials stored, handled, or processed at the Facility consist of municipal solid waste,

SSRM, construction and demolition debris, household hazardous waste, and petroleum products.

Potential sources of pollutants also include leaks or drips from trucks/ equipment operating on-site, and

petroleum products and other materials handled or stored on-site. A Hazardous Material Business Plan

(HMBP) and a Spill Prevention, control, and Countermeasure Plan (SPCC Plan) exists for this facility.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 8 Project No. 14-05406-20

4.1.1 Materials Inventory A list of industrial materials that the El Sobrante Landfill handles and stores at the facility is included in

Table 2. Table 2 includes the location where the industrial material is being received, stored, shipped, and

handles, as well as the storage method, typical handling frequency, and the likelihood of exposure to

stormwater.

4.1.2 Material Receiving Public vehicles and trucks enter the facility on a paved access road from the southwestern portion of the

El Sobrante Landfill. Municipal solid waste is accepted at the El Sobrante Landfill at approximately 7,000

tons per day. The following materials are received at El Sobrante Landfill.

Municipal solid waste and construction and demolition debris at the active face.

Contaminated soils for beneficial use throughout the landfill that are subject to Order No. R8-2014-0006 Amending WDRs for Active Landfills in Santa Ana Region.

SSRMs in the bays north of the administrative office area

Oils, lubricants, and other maintenance related materials in the maintenance area

Received materials can potentially migrate from the trucks while loading/unloading due to wind or track-

out. Paper, cardboard, aluminum, plastic and glass debris stored outside may expose these materials to

stormwater. Leaks of residual liquids from recyclable containers may be exposed to stormwater. In

addition, oil and fluid leaks from collection trucks during unloading operations could allow exposure of

these materials to stormwater. The potential sources of stormwater pollutants related to material receiving

in these areas include:

Solid waste, SSRMs, and contaminated soils during unloading operations.

Leaks of residual liquids from recyclable containers

Leaking of oil and fluids from collection trucks during unloading operations.

4.1.3 Material Storage & Handling El Sobrante Landfill stores SSRMs, recycled construction and demolition material, universal waste, used

oil, , oils, lubricants, and other maintenance related materials, and household hazardous materials / waste

in designated area of the facility.

With regards to hazardous materials, El Sobrante Landfill conducts waste load checks to remove any

hazardous materials found during waste disposal activities. Hazardous materials discovered during waste

load checks are stored temporarily in a secure facility before being transported off-site to a licensed

hazardous waste facility. The approximate rate of hazardous materials found in load varies each day but

is generally several batteries, gallons cans of paint, and quarts of oil on a monthly basis.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 9 Project No. 14-05406-20

Electronic wastes are stored in totes or gondolas and shipped to a licensed electronic waste recycler on a

bi-weekly basis.

4.1.4 Material Shipping El Sobrante Landfill uses wheel loaders to load SSRM materials onto truck trailers in the locations where

the materials are stored. Hazardous wastes are off-hauled off-site within 90 days. E-wastes are

segregated and off-hauled when holding containers reach capacity. Typically forklift trucks are used to

load aggregated household hazardous wastes and E-wastes into trucks. Typically, the loading/unloading

activities of household hazardous wastes and e-wastes are not conducted under cover and are potentially

exposed to stormwater.

4.2 Industrial Processes Industrial activities at the site include municipal waste disposal, on-site equipment fueling and repair, and

activities relating to maintenance of certified closed portion of the landfill. The most likely sources of

stormwater pollutants are industrial processes that result in the release of dust and particles, oil and

grease, metals, and organics.

These industrial processes and potential pollutant sources are discussed further by area and process in

the following subsections.

4.2.1 Equipment Maintenance and Fueling Maintenance of equipment is conducted on the northwestern portion of the Facility. The repairing

activities are conducted under a canopied building. Several drums and aboveground storage tank (ASTs)

are located in the maintenance area. Portions of the ground under the maintenance building is paved;

however, the area around the building is unpaved.

Fueling activities are conducted near the Site entrance and guard building and administrative trailers.

Oil and grease are the primary potential pollutants anticipated from these activities.

4.2.2 Gas Collection System Gas condensate is generated by the landfill gas collection system. The gas condensate is stored in a

12,000-gallon AST surrounded by a concrete secondary containment structure. Leachate generated from

the landfill is collected and stored in two 12,000-gallon ASTs surrounded by a concrete containment

structure. Leachate and condensate are commingled and utilized for dust control over lined areas of the

landfill.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 10 Project No. 14-05406-20

4.3 Dust and Particulate Generating Activities Operating vehicles and machinery on the aggregate base access roads and pads associated with the

Facility generate dust or particulates In the event that dust or particulate pollutants are be picked up by

stormwater, they would follow drainage patterns as shown in Figure 2. The Facility has a set protocol for

dust mitigation during dry weather periods, including visual inspections for the condition of the roads and

spraying the roads and nearby vegetation with water. The facility uses a formulated dust suppressant

containing magnesium chloride.

4.4 Significant Spills and Leaks According to facility records and personnel, no significant spills or leaks that discharged or had the

potential to discharge from the Facility’s stormwater conveyance system have occurred at this facility in

the past five (5) years, including industrial materials handled or stored at the Facility, toxic chemicals

listed in the Code of Federal Regulations, Title 40 (40 CFR), Part 302 or oil and hazardous substances in

excess of reportable quantities under 40 CFR Parts 110, 117, and 302.

Spills and leaks could potentially occur at the locations within the Facility where industrial materials are

handled or stored. These locations are shown on Figure 3.

Spills or leaks are to be addressed immediately in the manner discussed in the BMPs section. A

description of spills and the response are to be documented in the Annual Report. The PPT routinely

inspects the facility and records of these inspections are maintained. Appendix E includes a form for

describing significant spills and leaks and recording response procedures. Reporting is required for spills

of oil or hazardous substances greater than the reportable quantities described in 40 CFR Parts 302.4

and 117 and as described in the Spill Prevention Control and Countermeasures (SPCC) for the facility.

4.5 Non-Stormwater Discharges The facility has the following authorized non-stormwater discharges:

A water truck is operated daily during dry weather at the Facility to reduce dust and particulate

generation; the applied water typically evaporates or infiltrates into the aggregate base of the unpaved

roads.

Early morning dew and condensate does create run-off from the building roofs, the small quantity of clear

run-off typically evaporates.

Air conditioning units are located on the administrative trailer and discharge condensate to the

surrounding paved and unpaved parking areas. The small quantity of condensate continuously

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 11 Project No. 14-05406-20

evaporates or infiltrates and is generally not present during the wet season since the air conditioning units

are not operational.

Irrigation sprinklers are located in the planters near the office to water the landscaped areas. The

moderate quantity of irrigation water continuously infiltrates and is generally not present during rainy days.

4.6 Erodible Surfaces The unpaved areas (i.e., sideslopes, undeveloped areas, closed landfill areas, sedimentation basins, etc.)

and unpaved access roads and associated v-ditches have the potential to be eroded. However, BMPs

have been implemented at the site to reduce and eliminate erosion during wet weather periods. The

majority of the closed portions of the landfill have well established vegetation that lessens the erodible

potential.

4.7 Pollutant Source Assessment A potential pollutant source assessment was performed to identify those industrial activities potentially

contributing pollutants to stormwater discharge and the BMPs implemented, or to be implemented, to

reduce the potential for those pollutants into stormwater discharges. This assessment included review of

sampling, visual observation, and inspection records as part of the assessment; however, historic records

are not included as part of this SWPPP.

Industrial activities are identified in Sections 4.1 through 4.7 and BMPs are included in Sections 5 and 6.

The following information is summarized in Tables 2 and 3 and relevant elements of this information are

also shown on Figure 3, 4, and 5.

Areas of the Facility with likely sources of pollutants

Pollutants likely to be present in industrial stormwater discharges and authorized NSWDs

Approximate quantity, physical characteristics, and locations of each industrial material handled, produced, stored, recycled, or disposed

Degree to which the pollutants associated with those materials may be exposed to and mobilized by contact with stormwater.

Direct and indirect pathways by which pollutants may be exposed to stormwater or authorized NSWDs

There are no known industrial pollutants related to the receiving waters with 303(d) listed impairments.

Based on this initial desktop assessment, there are no additional parameters required to be included in

the MIP (Section 8) at this time to indicate the presence of listed impairments in industrial stormwater

discharges from the Facility.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 12 Project No. 14-05406-20

5.0 MINIMUM BMPS Minimum Best Management Practices (BMPs) generally consist of processes, prohibitions, procedures,

schedule of activities, etc., that reduce potential for exposure of stormwater and authorized non-

stormwater discharges. The minimum BMPs described in this section are required by the General Permit.

5.1 Good Housekeeping The Facility implements the good housekeeping BMPs describe below in order to reduce the impact of

potential pollutants. The Minimum BMPs described in the General Permit are italicized, with Facility-

specific implementation following.

i. Observe all outdoor areas associated with industrial activities including stormwater discharge locations, drainage areas, conveyance systems, waste handling/disposal areas, and perimeter areas impacted by off-facility materials or stormwater run-on to determine housekeeping needs. Any identified debris, waste, spills, tracked materials, or leaked materials shall be cleaned and disposed of properly.

El Sobrante Landfill observes parking lots, driveways, and storage areas and removes trash

and debris on a regular basis.

ii. Minimize or prevent material tracking

Facility personnel keep litter and debris picked up so that it is not tracked off-site. El Sobrante

Landfill sweeps the paved access road for the facility two times a week.

iii. Minimize dust generated from industrial materials or activities

The facility utilizes a water spray truck to minimize dust generation.

iv. Ensure that all facility areas impacted by rinse/wash waters are cleaned as soon as possible

Vehicles and equipment are cleaned in a wash bay connected to a clarifier at the

maintenance area.

v. Cover all stored industrial materials that can be readily mobilized by contact with stormwater

Petroleum products and aqueous landfill liquids are stored in ASTs with secondary

containment. Exposed metal equipment and supplies stored near the maintenance area are

removed/ recycled in a timely manner or are covered and stored on pallets.

vi. Contain all stored non-solid industrial materials (e.g., particulates, powders, shredded paper, etc.) that can be transported or dispersed via wind or contact with stormwater

El Sobrante Landfill stores waste oils/liquids in the waste oil AST located on the northwestern

portion of the site near the maintenance area. El Sobrante Landfill maintains suitable spill kits

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 13 Project No. 14-05406-20

near the hazardous material storage area and promptly implements established spill cleanup

procedures for leaks and spills.

vii. Prevent disposal of any rinse/wash waters or industrial materials into the stormwater system

Vehicles and equipment are cleaned in a wash bay connected to a clarifier at the

maintenance area. Industrial materials are not disposed of in the stormwater conveyance

system. Dry cleanup methods are utilized in the event of spills or leaks

viii. Minimize stormwater discharges from non-industrial areas (e.g., stormwater flows from employee parking area) that contact industrial areas of the facility

Where practicable, the site drainage pattern is such that stormwater discharges from non-

industrial areas such as the landscaped area do not contact the industrial areas of the facility.

ix. Minimize authorized NSWDs from non-industrials areas (e.g., potable water, irrigation water, fire hydrant testing, etc.) that contact industrial areas of the facility

Where practicable, the site drainage pattern is such authorized NSWDs from non-industrial

areas such as the landscaped area do not contact the industrial areas of the facility.

5.2 Preventative Maintenance The Facility implements the preventative maintenance procedures described below.

Identify equipment and systems used outdoors that may spill or leak potential stormwater pollutants

Observe the identified equipment and systems to detect leaks, or identify conditions that may result in the development of leaks

Establish an appropriate schedule for maintenance of identified equipment and systems

Establish procedure for prompt maintenance and repair of equipment, and maintenance of systems when conditions exist that may result in the development of spills or leaks

A member of the PPT performs weekly visual inspections using an established checklist that includes

checking for signs of deterioration of equipment, containers, and metal accessories that are stored

outside. The inspection identifies corrosion, structural failure, spills, leaks, etc. and equipment is repaired/

replaced as needed.

5.3 Spill and Leak, Prevention and Response The Facility implements the spill prevention procedures described below, and in accordance with the

Facility’s SPCC Plan.

Establish procedure and/or controls to minimize spills and leaks

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 14 Project No. 14-05406-20

Develop and implement spill and leak response procedures to prevent industrial materials

from discharging through the stormwater conveyance system. Spilled or leaked industrial material shall be cleaned and disposed of properly.

Identify and describe all necessary and appropriate spill and leak response equipment, location(s) of spill and leak response equipment, and spill or leak response equipment maintenance procedures

Identify and train appropriate spill and leak response personnel

El Sobrante Landfill properly labels and uses lids to seal cans and drums storing liquids and uses spigots,

pumps, and funnels to dispense and transfer liquids to reduce the possibility of spills. El Sobrante Landfill

uses drip pans or other protective devices for liquid transfer operations to catch incidental spillage and

drips from dispensing products from tanks, drums, barrels, or dispenser pumps. El Sobrante Landfill

stores used waste oil/liquids in an AST under cover and with secondary containment pending removal by

a hazardous waste disposal contractor. El Sobrante Landfill maintains spill cleanup kits near the material

storage areas.

Significant spills must be immediately reported to proper authorities. Reporting is required for spills of oil

or hazardous substances greater than the reportable quantities described in CFR Title 40, Parts 302.4

and 117. A form for describing significant spills and leaks and recording response procedures is included

in Appendix E. The Facility also follows response procedures as outlined in its SPCC.

5.4 Material Handling and Waste Management The Facility implements the material handling and site-generated waste management procedures

described below.

Prevent or minimize handling of industrial materials or wastes that can be readily mobilized by contact with stormwater during a storm event

Contain all stored non-solid industrial materials or wastes that can be transported or dispersed via wind erosion or contact with stormwater during handling

Cover industrial waste disposal containers and industrial materials storage containers that contain industrial materials when not in use

Divert run-on and stormwater generated from within the facility away from all stockpiled materials

Clean all spills of industrial materials/wastes that occur during handling in accordance with the spill response procedures

Observe and clean as appropriate, any other material/waste handling equipment or containers that can be contaminated by contact with industrial materials or wastes.

Equipment leak prevention and spill cleanup procedures are discussed in Sections 5.2 and 5.3.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 15 Project No. 14-05406-20

5.5 Erosion and Sediment Control Erosion of non-vegetated areas can cause sediment mobilization and increase sediment loading in

stormwater discharges. The following BMPs for erosion control will be implemented, if industrial activities

spread to erodible surfaces.

Implement effective wind erosion controls

Provide effective stabilization for erodible areas prior to a forecasted storm events

Maintain effective perimeter controls and stabilize all site entrances and exits to sufficiently control discharges of erodible materials from discharging or being tracked off the site

Divert run-on and stormwater generated from within the facility away from all erodible materials

Maintain drainage and erosion control systems and all-weather working surfaces at the site

Maintain vegetation on inactive earth surfaces prior to October 1 of each year. Advanced erosion and sediment control, structural controls, and specific implementation details are also discussed in Section 6.

Sediment basins are implemented. Design storm standards described in Section X.H.6 of the General Permit will be implemented for sediment basins that are consructed or upgraded after July 1, 2015.

5.6 Employee Training Program The Facility implements the employee training program procedures described below.

Team members implementing the various compliance activities in the SWPPP are properly trained to implement the requirements of the General Permit, including but not limited to: BMP implementation, BMP effectiveness evaluations, visual observations, and monitoring activities. If this facility enters Level 1 status, appropriate team members shall be trained by a QISP.

Appropriate training manuals or training materials are prepared or acquired.

Personnel need to be trained, their responsibilities, and the type of training they shall receive have been identified.

A training schedule has been developed and is described below.

Documentation of all completed training classes and the personnel that received training is maintained in the SWPPP

The Facility has established a training program. The PPT trains annually or provides annual training for

current and future employees. The Facility provides training for new employees within 30 days of

involvement with the SWPPP program. This training includes BMP implementation, BMP effectiveness

evaluations, visual observations, and monitoring activities. Two employees are trained on sampling

procedures and methodologies.

The Facility employees that have direct responsibilities in areas of the facility that have the potential to

impact stormwater receive SWPPP training annually. More frequent training will be conducted as

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 16 Project No. 14-05406-20

necessary to address employee turnover. All PPT and employee training is documented and the records

are stored with the SWPPP. Records of employee training are kept for at least 5 years. Employee training

records may be kept on the form provided in Appendix D.

5.7 Quality Assurance and Record Keeping The Facility implements the quality assurance and record keeping procedures described below.

Develop and implement management procedures to ensure that appropriate staff implements all elements of the SWPPP, including the Monitoring Implementation Plan (MIP).

Develop a method of tracking and recording the implementation of BMPs identified in the SWPPP

Maintain the BMP implementation records, training records, and records related to any spills and clean-up related response activities for a minimum of five (5) years

The PPT or facility manager is responsible for ensuring that all elements of the SWPPP, including the MIP

and BMPs, are implemented, that BMP implementation is tracked and recorded, and that all records

required by the General Permit and SWPPP are maintained for a minimum of 5 years. Requirements are

tracked through the facility’s CYCLE database. Quality assurance activities undertaken are documented

and entered into the SWPPP records.

5.8 Minimum BMP Exceptions The facility implements all minimum BMPs in the General Permit as described above. If the described

minimum BMPS are not fully implemented because they have been determined to either not reflect a best

industry practice, are not economically practicable, or are not economically achievable; those exceptions

are described in future revisions in the SWPPP and are included in Appendix A.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 17 Project No. 14-05406-20

6.0 ADVANCED BMPS Advanced BMPs reduce or prevent discharges of pollutants in stormwater discharge in a manner that

reflects best industry practice considering technological availability and economic practicability and

availability. Examples include:

Overhead coverage

Retention ponds, basins or surface impoundments

Berms or other run-on/run-off channeling devices

Secondary containment structures

Treatment through inlet controls, filtration, or vegetative swales that reduce the pollutants in surface waters discharged from the site.

The Facility implements advanced BMPs as necessary, described below.

6.1 Exposure Minimization El Sobrante Landfill stores petroleum products, oil filters, batteries, and other hazardous waste materials

in covered locations. This overhead coverage reduces or prevents the potential for stormwater pollutants

associated with these activities from contacting or entering stormwater. These potential targeted

pollutants include TSS and O&G.

6.2 Stormwater Containment and Discharge Reduction BMPs

6.2.1 Contaminated Soil Acceptance BMPs ESL accepts contaminated soils for beneficial use that are subject to Order No. R8-2014-0006 Amending WDRs for Active Landfills in Santa Ana Region. ESL ensures that waste constituents are not mobilized in a way that would adversely affect beneficial uses of waters of the State through implementation of the following BMPs.

The use of contaminated soils is limited by administrative procedures, but contaminated soils may be accepted at any time, but will not be deployed for beneficial use during wet weather events.

Drainage diversion structures to control surface water run-on and run-off to limit interaction with the wastes exposed in the landfill working area are implemented

Drainage retention facilities to capture or control surface waters to minimize stormwater run-off from the site

6.2.2 Sedimentation Basins The Facility maintains four (4) sedimentation basins to detain stormwater at the facility. The locations of

the sedimentation basins are:

Sedimentation Basin 1 is located on the northern portion of the Facility near Outfall North

Sedimentation Basin 2 is located on the northwestern portion of the Facility near Outfall 002

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 18 Project No. 14-05406-20

Sedimentation Basin 3 is located on the southern portion of the Facility near Outfall 001

Sedimentation Basin 4 is located on the southern portion of the Facility near Outfall South

Temporary sedimentation basins may be used to contain and hold stormwater runoff during construction

of expansion areas, placement of landfill cap/cover, and backfilling/grading projects. The Facility

maintains one large retention basin to retain stormwater from the central portion of the facility. Water from

the basins do not flow directly to stormwater discharge locations but if needed, may be pumped to

existing discharge locations after sediment has settled out.

6.2.3 Down Drain Maintenance Down drain inlets are cleaned prior to the wet season and before major storm events, if partially full with

sediments.

6.3 Treatment Control BMPs There is an oil/water separator (clarifier) located at the maintenance shop area. Generalized operation

and preventative maintenance procedures are as follows.

Depending on site usage of wash bay, content of oil/water separator is pumped dry using WM approved third party transporter and hauled to and disposed at permitted Class II landfill facility.

Content is removed at a minimum of once per quarter

Content is tested and analyzed annually to assure chemical composition of waste remains the same

Any needed repairs of separator are done on an as needed basis

Additional advanced treatment control BMPs may be considered consistent with the exceedance

Response Action (ERA) process if stormwater Numeric Action Levels (NALs) are not met.

6.4 Other Advanced BMPs

6.4.1 Secondary Containment All fuel and waste oil storage tanks and containers at the Facility have secondary containment equipment

to prevent or reduce the potential for stored liquids to contact stormwater. The secondary containment

reduces or prevents the potential for O&G impact to stormwater.

6.4.2 Hydrojetting Stormdrain pipes are inspected prior to the start of the wet season; if sediment buildup is observed those

pipes are hydro jetted so as to remove sediment buildup.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 19 Project No. 14-05406-20

6.4.3 Track-out Prevention Stabilized entrances/exits or rumble strips are placed at the defined access points to selected industrial

activities.

6.4.4 Erosion Control Naturally occurring vegetation at the Facility filters sediment from stormwater before discharge.

Vegetation can also provide a slight pH buffering effect. The stormwater drainage systems in place have

been designed to divert stormwater away from operational areas and toward the sedimentation basin and

vegetated areas where practicable.

The facility will implement selected sediment control measures that may include silt fence,

geocomposites, or 18 inch Filtrexx Soxx.

Specific narrative descriptions of BMPs that are implemented, to the extent practicable, at the Facility are

listed by category in each of the following sections. Additionally, copies of California Stormwater Quality

Association (CASQA) BMP Handbook fact sheets for erosion and sediment control BMPs are included for

implementation guidance and reference in Appendix G.

More generally, erosion control, also referred to as soil stabilization, consists of source control measures

that are designed to prevent soil particles from detaching and becoming transported in storm water runoff.

Erosion control BMPs protects the soil surface by covering and/or binding soil particles. The Facility will

incorporate erosion control measures that are effective and result in the reduction of sediment related

pollutants in stormwater discharges and authorized non-stormwater discharges. The Facility will

implement the following practices as-needed for effective temporary and longer-term erosion control:

Preserve existing vegetation where practicable and when feasible.

Implement focused erosion control measures prior to the wet season.

Apply hydroseed for vegetation development on sparse vegetated areas.

Focus on controlling erosion in concentrated flow paths.

Sufficient erosion control materials will be maintained on-site to allow implementation in conformance with the SWPPP.

The BMPs that are considered, and where appropriate implemented at the Facility to prevent erosion

following soil disturbing areas include:

6.4.4.1 Scheduling Operating activities are scheduled with the incorporation of both soil stabilization and

sediment control measure BMPs to reduce the discharge of pollutants. The schedule limits exposure of disturbed soil to wind, rain, and stormwater run-on and run-off where practicable.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 20 Project No. 14-05406-20

6.4.4.2 Preservation of Existing Vegetation

Existing vegetation is maintained to the extent practicable.

6.4.4.3 Seeding

Seeding or other erosion control BMPs are applied in areas to protect disturbed soil areas from soil erosion. The seed or other erosion control BMPs are applied after any grading operations.

6.4.4.4 Geotextile and Mats

Geotextile or erosion control matting will be installed in v-ditches where the erosive potential exceeds the resistance of the native compacted soil; the application of erosion control matting is performed in accordance with manufacturer’s specifications. Erosion Control Mats (ECMs) should not include any synthetic netting component because of this material's potential adverse impact to Wildlife.

6.4.4.5 Slope Protection Slope drains consist of a pipe used to intercept and direct surface runoff into a stabilized

watercourse, trapping device, or stabilized area. Slope drains are used with earth dikes and drainage ditches to intercept and direct surface flow away from slope areas to protect recently cut or fill slopes.

6.4.4.6 Non-vegetative stabilization Non-vegetative stabilization methods may be used for permanent stabilization of areas

prone to erosion. These methods will be used only where vegetative options are not feasible such as areas of vehicular traffic (access roads) or areas with rocky substrate, infertile or droughty soils where vegetation would be difficult to establish.

6.4.4.7 Soil Binders Soil binding consists of application and maintenance of a soil stabilizer to exposed soil

surfaces and may be used in select areas of the Facility. Soil binders are materials applied to the soil surface to temporarily prevent water and wind induced erosion of exposed soils. Example of soil binders that are recommended are:

Earthguard is a useful soil stabilizing emulsion specifically formulated to reduce erosion and sediment runoff. Earthguard can be applied by water truck or by spray application.

Gorilla-Snot is useful as a biodegradable liquid copolymer to stabilize and solidify any soil or aggregate as well as provide erosion control and dust suppression.

6.4.5 Sediment Control Sediment controls are structural measures that are intended to complement and enhance the selected

erosion control measures and reduce sediment discharges. Sediment controls are designed to intercept

and remove or settle out or filter soil particles that have been detached and transported by the force of

water. The Facility implements sediment control measures that are effective and result in the reduction of

sediment related pollutants in stormwater discharges and authorized non-stormwater discharges.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 21 Project No. 14-05406-20

Sufficient quantities of temporary sediment control materials will be maintained on-site to allow

implementation of temporary sediment controls in the event of predicted rain and for rapid response. This

includes implementation requirements of BMPs in active areas and non-active areas that require

deployment before the onset of rain. The BMPs considered for implementation to prevent sediment

migration from disturbed soil areas include:

6.4.5.1 Fiber Rolls (straw wattles or Filtrexx Soxx®) Fiber rolls or Filtrexx Soxx® are installed at strategic locations at the facility. Fiber rolls are

typically placed along the perimeter of the facility. Fiber Rolls should not include any synthetic component. Heavy sediment laden run-on that flows onto the access road should be controlled.

6.4.5.2 Sweeping Paved areas are swept with a regenerative sweeper daily, prior to an anticipated storm

event, or as needed to control of excessive dirt and dust. Sweeping focuses in areas where noticeable tracking of materials occurs.

6.4.5.3 Storm Drain Inlet Protection (within hardscape areas) Drain inlets (DIs) within the hardscaped areas of the facility have drain inlet protection.

The Drain inlet protection is intended to filter out any sediment and pollutants. DI protection is installed in a manner that will not cause ponding or pose a threat to traffic safety. If ponding does cause an issue the source of the ponding will be identified and corrective actions taken if necessary. During critical operations where potential exists of non-stormwater entering the storm drain inlet, the inlet should be sealed off with urethane sheets, plastic covers, or an equivalent product. Once the critical operation is completed the DIs should be opened up again.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 22 Project No. 14-05406-20

7.0 TEMPORARY SUSPENSION OF INDUSTRIAL ACTIVITIES If the facility plans to temporarily suspend industrial activities for ten or more consecutive calendar days

during a reporting year, the facility may also suspend monitoring if it is infeasible to conduct monitoring

while industrial activities are suspended (e.g., the facility is not staffed, or the facility is remote or

inaccessible) and the facility has been stabilized.

The facility will implement appropriate stabilization BMPs (such as complete coverage) to achieve

compliance with this General Permit during the temporary suspension of the industrial activity by avoiding

any exposure of industrial materials and industrial activities to stormwater.

Once all necessary BMPs have been implemented to stabilize, the facility is not required to:

Perform monthly visual observations; or,

Perform sampling and analysis; if it is infeasible to do so (e.g. facility is remotely located).

The facility shall upload via SMARTS seven calendar days prior to the planned temporary suspension of

industrial activities:

Revised and updated SWPPP (if above listed stabilization BMPs are not deemed adequate at the time) specifically addressing the facility stabilization BMPs;

The justification for why monitoring is infeasible at the facility during the period of temporary suspension of industrial activities;

The date the facility is fully stabilized for temporary suspension of industrial activities; and,

The projected date that industrial activities will resume at the facility.

Upon resumption of industrial activities the facility shall, via SMARTS, confirm and/or update the date the

facility’s industrial activities have resumed. At this time, the Discharger is required to resume all

compliance activities.

The Regional Water Board may review the submitted information pertaining to the temporary suspension

of industrial activities. Upon review, the Regional Water Board may request revisions or reject the the

facility’s request to temporarily suspend monitoring.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 23 Project No. 14-05406-20

8.0 MONITORING IMPLEMENTATION PLAN (MIP) The MIP in this section describes a facility-specific monitoring program to provide indicator monitoring

information for assessing the levels of pollutants in stormwater discharges, the effectiveness of BMPs to

prevent or reduce pollutants, and the need for corrective action. The objectives of the MIP are to:

Assess whether BMPs addressing pollutants in industrial stormwater discharges and authorized NSWDs are effective for compliance with the effluent and receiving water limitations of the General Permit.

Measure the presence of pollutants in industrial stormwater discharges and authorized NSWDs relative to their respective Numeric Action Levels (NALs), and determine whether an Exceedance Response Action process is required.

Assess whether the suite of BMPs implemented at the facility are effective in reducing or preventing pollutants in industrial stormwater discharges and authorized NSWDs.

The MIP includes a description of the following:

Discharge locations

Visual monitoring procedures

Sampling requirements and sample handling procedures

A list of analytical methods and related detection limits

Justifications for alternative discharge locations, representative sampling reduction and/or qualified combined samples (if needed)

Visual and sample event observation response procedures

PPT member assignments

8.1 Discharge Locations There are a total of seven (7) industrial stormwater discharge locations. The stormwater discharge

locations at the Facility are described as follows and are shown on Figure 3:

Outfall 001 (Sediment Basin 3 located on the southern portion of the facility)

Outfall 002 (Sediment Basin 2 located on the northwester portion of the facility)

Outfall 003 (along the Facility access road located on the southern portion of the facility)

Outfall North (Sediment Basin 1 located on the northern portion of the facility)

Outfall South (Sediment Basin 4 located on the southeastern portion of the facility)

Outfall A (near the former clay mine located on the northwestern portion of the facility)

Outfall B (located along the access road on the southwestern portion of the facility)

8.2 Visual Observations The General Permit requires two basic types of visual observations designed to identify sources of

pollutants.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 24 Project No. 14-05406-20

Monthly Visual Observations- conducted on a day with no precipitation during daylight hours to observe

authorized and unauthorized NSWDs and potential pollutant sources.

Sampling Event Visual Observations- conducted at the same time that sampling occurs to observe the

quality of discharges and sources of observed pollutants.

8.2.1 Monthly Visual Observations A member of the PPT visually observes at least monthly at each drainage area. The scope of the visual

observation includes the following elements:

The presence or indications of prior, current, or potential unauthorized NSWDs and their sources

Authorized NSWDs and associated BMPs

Implemented BMPs

Potential pollutant sources including industrial activity areas, outdoor equipment, and other potential industrial pollutant sources

Each area of industrial activity

The inspections are to be conducted during daylight hours, during scheduled facility operating hours, and

on days without precipitation. Inspectors are to document the presence or indication of any non-

stormwater discharge, pollutant characteristic (i.e., floating and suspended material, oil and grease,

discoloration, turbidity, odor, etc.), and the source. The facility’s authorized non-stormwater discharges (if

any) and associated BMPs are also observed.

Visual observations are to be documented on the applicable form located in Appendix F.

8.2.2 Sampling Event Visual Observations A member of the PPT visually observes stormwater discharge at the time of sampling. Sampling is

required four times per year, twice during the first half of the year (July 1 through December 31) and twice

during the second half of the year (January 1 through June 30). Sampling and corresponding visual

observations are only required of stormwater discharges that meet the sampling criteria in Section 8.3.

Observations are not required when dangerous weather conditions exist, discharge occurs outside

scheduled facility operating hours, and events not sampled are explained in the Annual Report.

Observations are also not required for drainage areas that have no exposure to industrial activities and

materials.

The inspections include visual observations of stormwater runoff to evaluate the presence of floating or

suspended materials, oil and grease, discoloration, turbidity, or other signs of pollutant impact to

stormwater runoff. Observations are made to assess the proper performance of stormwater collection and

diversion structures, e.g., surface drains. The SWPPP shall be revised, as necessary, if visual

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 25 Project No. 14-05406-20

observations indicate that the document is inaccurate or additional BMPs are needed to control or prevent

pollutants in stormwater discharges.

A member of the PPT is assigned to perform visual stormwater observations during the sample collection.

A back-up member of the team shall be assigned when the primary PPT member is absent or

unavailable. Visual observations are to be documented on the applicable form located in Appendix F.

8.2.3 Visual Observation Records and Response Procedures Appendix F includes templates for the required visual observations.

Records of the observations include the name of the observer, date, time, locations observed,

observations, and response action(s) taken.

In the event that a visual observation indicates a condition that may inadequately reduce or prevent

pollutants in industrial stormwater, corrective action will be taken. Examples of observations that may

require a corrective action include but are not limited to the following.

Unauthorized NSWD

Presence of floating or suspended materials, oil and grease, discoloration, turbidity, or other signs of pollutants in a discharge

Inadequately implemented BMP

Inadequate BMP maintenance

New pollutant source or a change in character of an existing pollutant source

Examples of corrective action that may be appropriate to an observation may include the following.

Eliminate unauthorized non-stormwater discharges and/or to improve BMP implementation

Investigate the source of observed pollutants

Direct Facility personnel to implement a housekeeping task

Eliminate or implement new BMP(s) or improve existing BMP(s) to address the source of pollutants;

Maintain BMP(s)

Develop New BMP(s)

The SWPPP shall be revised, as necessary, if visual observations indicate that the document is

inaccurate or additional or revised BMPs are needed address the observations or to reduce or prevent

pollutants in industrial stormwater discharges.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 26 Project No. 14-05406-20

8.3 Sampling and Analysis The General Permit requires collection of stormwater discharges for laboratory analysis from a Qualifying

Storm Event (QSE). The General Permit describes a QSE as when stormwater discharge occurs from at

least one drainage area when the discharge is preceded by at least 48 hours with no discharges from any

of the drainage areas. Samples are to be collected from two QSEs occurring within the first half of the

year (January 1 through June 30) and two QSEs occurring within the second half of the year (July 1

through December 31).

Samples are to be collected from each drainage area at all discharge locations with two exceptions: (1)

when the facility qualifies for Representative Sampling Reduction, and (2) when stormwater is stored or

contained. Following the criteria for Representative Sample Reduction, the facility’s number of sampling

locations may be reduced if discharge locations are substantially similar, the reduction is justified in the

MIP, and the Discharger certifies it in the Stormwater Multiple Application and Report Tracking System

(SMARTS). When stormwater is stored or contained, sampling occurs at the time the stored water is

released. A PPT member or designee is to collect stormwater samples under the following conditions:

Within 4 hours of the start of discharge or at the start of facility operations if the QSE occurs within the previous 12-hour period.

During regularly scheduled facility operating hours.

During daylight hours.

When weather and site conditions are safe.

Surface water (stormwater runoff) monitoring is performed as part of the NPDES program. There are a

total of seven (7) stormwater runoff monitoring locations. The stormwater discharge monitoring locations

at the Facility are as follows and as shown on Figure 3:

Outfall 001

Outfall 002

Outfall 003

Outfall North

Outfall South

Outfall A

Outfall B

The General Permit requires justifications for any of the following monitoring options that could be

applicable to the facility:

Alternative discharge locations

Representative Sampling Reduction

Qualified Combined Samples

Since the facility is not using any of the above monitoring options, no justifications are required.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 27 Project No. 14-05406-20

8.4 Parameters for Analysis, Methods, Detection Limits, and USEPA

Benchmark values The minimum parameters for sampling and analysis include pH, TSS, and O&G.

Pursuant to requirements of the General Permit, individual samples of stormwater from this site are to be

field tested with a calibrated portable instrument for pH. Collected samples are analyzed at the laboratory

or in the field for the parameters listed in Table 5 using the associated method, holding time, and USEPA

Benchmark values for the discharge locations as shown in Table 4.

8.4.1 Sector Required Analysis Based on the standard industrial classification (SIC) codes for specific industrial activities conducted at

the Facility, the following sector- required analyses are specified in the General Permit monitoring

program.

8.4.1.1 SIC Code 4953 Total Iron by USEPA 200.7/200.8.

Table 4 displays an overview of the sampling procedures.

8.5 Sample Collection and Handling Procedure Samples are to be collected in bottles that are either unpreserved (pH and TSS) or preserved (O&G and

iron). If the sample analytical method requires an unpreserved bottle, the bottle may be placed directly in

the flow of water to collect the sample. If a preserved bottle is required, the sample must be collected in

an unpreserved bottle then transferred to the bottle containing preservative in order to avoid washing the

preservative out of the bottle. Obtain guidance on sample collection, analytical methods, sample

preservation, and sample handling from the Stormwater Sample Collection and Handling Instructions

attached to the General Permit and from the analytical laboratory. An example of the chain of custody is

included in Appendix F.

The following procedure is to be followed to, first, determine when to sample and, second, ensure sample

integrity:

Obtain appropriate sample bottles from the laboratory to have on hand prior to the wet season.

Track weather forecasts to determine the expected arrival date and time of the storm event and quantity of rainfall.

Review weather data to determine if the requisite 48 hours of dry weather has elapsed prior to the anticipated storm event.

After rain has begun falling, check if the storm event is creating discharge and it is safe to collect stormwater.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 28 Project No. 14-05406-20

If stormwater is discharging from the site into the drains, collect samples within the first

four hours and label for submittal to the analytical laboratory.

Store the samples in a cooler with ice or frozen ice packs, complete the chain of custody form, and submit the samples to the lab or have them picked up by a courier prior to the close of business on the same day that they are collected.

8.5.1 Field Calibration Procedures pH will be monitored using:

wide range litmus pH paper or other equivalent pH test kits, or

a calibrated portable instrument for pH, or

methods in accordance with 40 Code of Federal Regulations 136 for testing storm water.

If a calibrated portable instrument for pH is used, the PPT member shall ensure that all field

measurements are conducted in accordance with the portable instrument accompanying manufacturer’s

instructions. It is recommended that an equipment calibration is performed 24 hours prior an announced

rain event with a 50% greater probability of precipitation on the NOAA website.

8.6 Monitoring Methods and Exceptions The stormwater discharges observed and collected are representative of the stormwater discharge in

each drainage area of the facility. If discharges are impacted by run-on from an adjacent facility, an

alternate visual monitoring and sample collection location shall be identified. If visual observation and

sample collection locations are difficult to inspect and sample, an alternate location representative of the

facility’s stormwater discharges may be identified.

Sample collection or inspections are not required during dangerous weather conditions (i.e., flooding, high

winds, or electrical storms) or outside scheduled operating hours. Documentation of dangerous conditions

preventing sampling or inspections shall be entered into the site record.

8.7 NALs and NAL Exceedances The Facility compares the results to the two types of NAL values in Table 4 to determine whether either

type of NAL has been exceeded for each applicable parameter. The two types of potential NAL

exceedances are:

8.7.1 Annual NAL exceedance The Facility determines the average concentration for each parameter using the results of all the sampling

and analytical results for the entire Facility for the reporting year (i.e., all "effluent" data). The Facility

compares the average concentration for each parameter to the corresponding annual NAL values in

Table 4. An annual NAL exceedance occurs when the average of all the analytical results for a parameter

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 29 Project No. 14-05406-20

from samples taken within a reporting year exceeds the annual NAL value for that parameter listed in

Table 4.

8.7.2 Instantaneous maximum NAL exceedance The Facility compares all sampling and analytical results from each distinct sample (individual or

combined) to the corresponding instantaneous maximum NAL values in Table 4. An instantaneous

maximum NAL exceedance occurs when two (2) or more analytical results from samples taken for any

single parameter within a reporting year exceed the instantaneous maximum NAL value (for TSS and

O&G) or are outside of the instantaneous maximum NAL range for pH.

8.8 Exceedance Response Actions

8.8.1 Baseline Status At the beginning of NOI Coverage, the Facility has baseline status for all parameters.

8.8.2 Level 1 Status Baseline status changes for any given parameter to Level 1 status if sampling results indicate an NAL

exceedance for that same parameter. Level 1 status commences on July 1 following the reporting year

during which the exceedance(s) occurred.

8.8.2.1 Level 1 ERA Evaluation By October 1 following commencement of Level 1 status for any parameter with sampling results

indicating an NAL exceedance, the facility shall:

1. Complete an evaluation, with the assistance of a QISP, of the industrial pollutant sources at the Facility that are or may be related to the NAL exceedance(s); and,

2. Identify in the evaluation the corresponding BMPs in the SWPPP and any additional BMPs and SWPPP revisions necessary to prevent future NAL exceedances and to comply with the requirements of this General Permit. Although the evaluation may focus on the drainage areas where the NAL exceedance(s) occurred, all drainage areas shall be evaluated.

8.8.2.2 Level 1 ERA Report Based upon the above evaluation, the Facility shall, as soon as practicable but no later than January 1

following commencement of Level 1 status:

3. Revise the SWPPP as necessary and implement any additional BMPs identified in the evaluation;

4. Certify and submit via SMARTS a Level 1 ERA Report prepared by a QISP that includes the following:

A summary of the Level 1 ERA Evaluation required in Section 8.8.2.1 above; and,

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 30 Project No. 14-05406-20

A detailed description of the SWPPP revisions and any additional BMPs for each

parameter that exceeded a NAL.

5. Certify and submit via SMARTS the QISP’s identification number, name, and contact information (telephone number, e-mail address).

The Facility Level 1 status for a parameter will return to Baseline status once a Level 1 ERA report has

been completed, all identified additional BMPs have been implemented, and results from four (4)

consecutive QSEs that were sampled subsequent to BMP implementation indicate no additional NAL

exceedances for that parameter.

8.8.2.3 NAL Exceedances Prior to Implementation of Level 1 Status BMPs. Prior to the implementation of an additional BMP identified in the Level 1 ERA Evaluation or October 1,

whichever comes first, sampling results for any parameter(s) being addressed by that additional BMP will

not be included in the calculations of annual average or instantaneous NAL exceedances in SMARTS.

8.8.3 Level 2 Status Level 1 status for any given parameter changes to Level 2 status if sampling results indicate an NAL

exceedance for that same parameter while the facility is in Level 1. Level 2 statuses will commence on

July 1 following the reporting year during which the NAL exceedance(s) occurred.

8.8.3.1 Level 2 ERA Action Plan Level 2 ERA Action Plan prepared by a QISP that addresses each new Level 2 NAL exceedance by

January 1 following the reporting year during which the NAL exceedance(s) occurred. For each new Level

2 NAL exceedance, the Level 2 Action Plan will identify which of the demonstrations in Section 8.8.3.2 the

Facility has selected to perform. A new Level 2 NAL exceedance is any Level 2 NAL exceedance for 1) a

new parameter in any drainage area, or 2) the same parameter that is being addressed in an existing

Level 2 ERA Action Plan in a different drainage area.

The Facility shall certify and submit via SMARTS the QISP’s identification number, name, and contact

information (telephone number, e-mail address) if this information has changed since previous

certifications.

The Level 2 ERA Action Plan shall at a minimum address the drainage areas with corresponding Level 2

NAL exceedances.

All elements of the Level 2 ERA Action Plan shall be implemented as soon as practicable and completed

no later than 1 year after submitting the Level 2 ERA Action Plan.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 31 Project No. 14-05406-20

The Level 2 ERA Action Plan shall include a schedule and a detailed description of the tasks required to

complete the Discharger’s selected demonstration(s) as described below in Section 8.8.3.2.

8.8.3.2 Level 2 ERA Technical Report On January 1 of the reporting year following the submittal of the Level 2 ERA Action Plan, the Facility with

Level 2 status certifies and submits a Level 2 ERA Technical Report prepared by a QISP that includes

one or more of the following demonstrations:

8.8.3.2.1 Industrial Activity BMPs Demonstration This includes the following requirements, as applicable:

6. Includes a description of the industrial pollutant sources and corresponding industrial pollutants that are or may be related to the NAL exceedance(s);

7. Includes an evaluation of all pollutant sources associated with industrial activity that are or may be related to the NAL exceedance(s);

8. Where all of the Facility’s’ implemented BMPs, including additional BMPs identified in the Level 2 ERA Action Plan, achieve compliance with the effluent limitations of this General Permit and are expected to eliminate future NAL exceedance(s), the Facility shall provide a description and analysis of all implemented BMPs;

9. In cases where all of the Facility’s implemented BMPs, including additional BMPs identified in the Level 2 ERA Action Plan, achieve compliance with the effluent limitations of this General Permit but are not expected to eliminate future NAL exceedance(s), the Discharger shall provide, in addition to a description and analysis of all implemented BMPs:

An evaluation of any additional BMPs that would reduce or prevent NAL exceedances;

Estimated costs of the additional BMPs evaluated; and,

An analysis describing the basis for the selection of BMPs implemented in lieu of the additional BMPs evaluated but not implemented.

10. The description and analysis of BMPs required above shall specifically address the drainage areas where the NAL exceedance(s) responsible for the Discharger’s Level 2 status occurred, although any additional Level 2 ERA Action Plan BMPs may be implemented for all drainage areas; and,

11. If an alternative design storm standard for treatment control BMPs (in lieu of the design storm standard for treatment control BMPs Described in Section X.H.6 in this General Permit) will achieve compliance with the effluent limitations of this General Permit, the Discharger shall provide an analysis describing the basis for the selection of the alternative design storm standard.

8.8.3.2.2 Non-Industrial Pollutant Source Demonstration 12. A statement that the Facility has determined that the exceedance of the NAL is

attributable solely to the presence of non-industrial pollutant sources. (The pollutant may also be present due to industrial activities, in which case the Facility must demonstrate that the pollutant contribution from the industrial activities by itself does not result in an NAL exceedance.) The sources shall be identified as either run-on from adjacent

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 32 Project No. 14-05406-20

properties, aerial deposition from man-made sources, or as generated by on-site non-industrial sources;

13. A statement that the Facility has identified and evaluated all potential pollutant sources that may have commingled with stormwater associated with the Facility’s industrial activity and may be contributing to the NAL exceedance;

14. A description of any on-site industrial pollutant sources and corresponding industrial pollutants that are contributing to the NAL exceedance;

15. An assessment of the relative contributions of the pollutant from (1) stormwater run-on to the Facility from adjacent properties or non-industrial portions of the Discharger’s property or from aerial deposition and (2) the stormwater associated with the Discharger’s industrial activity;

16. A summary of all existing BMPs for that parameter; and,

17. An evaluation of all on-site/off-site analytical monitoring data demonstrating that the NAL exceedances are caused by pollutants in stormwater run-on to the facility from adjacent properties or non-industrial portions of the Facility property or from aerial deposition.

8.8.3.2.3 Natural Background Pollutant Source Demonstration 18. A statement that the Facility has determined that the NAL exceedance is attributable

solely to the presence of the pollutant in the natural background that has not been disturbed by industrial activities. (The pollutant may also be present due to industrial activities, in which case the Facility must demonstrate that the pollutant contribution from the industrial activities by itself does not result in an NAL exceedance);

19. A summary of all data previously collected by the Facility, or other identified data collectors, that describes the levels of natural background pollutants in the stormwater discharge;

20. A summary of any research and published literature that relates the pollutants evaluated at the facility as part of the Natural Background Source Demonstration;

21. Map showing the reference site location in relation to the Facility along with available land cover information;

22. Reference site and test site elevation;

23. Available geology and soil information for reference and test sites;

24. Photographs showing site vegetation;

25. Site reconnaissance survey data regarding presence of roads, outfalls, or other human-made structures; and,

26. Records from relevant state or federal agencies indicating no known mining, forestry, or other human activities upstream of the proposed reference site.

8.8.3.3 Level 2 ERA Technical Report Submittal 27. The Facility shall certify and submit via SMARTS the Level 2 ERA Technical Report

described in Section 8.8.3.2 above.

28. The State Water Board and Regional Boards (Water Boards) may review the submitted Level 2 ERA Technical Reports. Upon review of a Level 2 ERA Technical Report, the Water Boards may reject the Level 2 ERA Technical Report and direct the Facility to take further action(s) to comply with the General Permit.

29. The Facility with Level 2 status who have submitted the Level 2 ERA Technical Report are only required to annually update the Level 2 ERA Technical Report based upon

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 33 Project No. 14-05406-20

additional NAL exceedances of the same parameter and same drainage area (if the original Level 2 ERA Technical Report contained an Industrial Activity BMP Demonstration and the implemented BMPs were expected to eliminate future NAL exceedances in accordance with Section XII.D.2.a.ii), Facility operational changes, pollutant source(s) changes, and/or information that becomes available via compliance activities (monthly visual observations, sampling results, annual evaluation, etc.). The Level 2 ERA Technical Report shall be prepared by a QISP and be certified and submitted via SMARTS by the Facility with each Annual Report. If there are no changes prompting an update of the Level 2 ERA Technical Report, as specified above, the Facility will provide this certification in the Annual Report that there have been no changes warranting re-submittal of the Level 2 ERA Technical Report.

30. Facilities are not precluded from submitting a Level 2 ERA Action Plan or ERA Technical Report prior to entering Level 2 status if information is available to adequately prepare the report and perform the demonstrations described above. A facility who chooses to submit a Level 2 ERA Action Plan or ERA Technical Report prior to entering Level 2 status will automatically be placed in Level 2 in accordance to the Level 2 ERA schedule.

8.8.3.4 Eligibility for Returning to Baseline Status Facilities with Level 2 status who submit an Industrial Activity BMPs Demonstration in accordance with

Section 8.8.3.2.1 above and have implemented BMPs to prevent future NAL exceedance(s) for the Level

2 parameter(s) shall return to baseline status for that parameter, if results from four (4) subsequent

consecutive QSEs sampled indicate no additional NAL exceedance(s) for that parameter(s). If future NAL

exceedances occur for the same parameter(s), the Facility’s Baseline status will return to Level 2 status

on July 1 in the subsequent reporting year during which the NAL exceedance(s) occurred. The Facility

shall update the Level 2 ERA Technical Report as required above in Section 8.8.3.2.

The Facility is ineligible to return to baseline status if they submit any of the following:

A industrial activity BMP demonstration in accordance with Section 8.8.3.2.1 above;

An non-industrial pollutant source demonstration; or,

A natural background pollutant source demonstration.

8.8.3.5 Level 2 ERA Implementation Extension 31. If additional time is required to submit the Level 2 ERA Technical Report, the Facility shall

be automatically granted a single time extension for up to six (6) months upon submitting the following items into SMARTS, as applicable:

Reasons for the time extension;

A revised Level 2 ERA Action Plan including a schedule and a detailed description of the necessary tasks still to be performed to complete the Level 2 ERA Technical Report; and

A description of any additional temporary BMPs that will be implemented while permanent BMPs are being constructed.

32. The Regional Water Board will review Level 2 ERA Implementation Extensions for completeness and adequacy. Requests for extensions that total more than six (6) months are not granted unless approved in writing by the Water Boards. The Water Boards may:

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 34 Project No. 14-05406-20

1. Reject or revise the time allowed to complete Level 2 ERA Implementation

Extensions,

2. Identify additional tasks necessary to complete the Level 2 ERA Technical Report, and/or

3. Require the Discharger to implement additional temporary BMPs.

8.9 Annual Comprehensive Facility Compliance Evaluation (Annual Evaluation) The RP for the site performs one comprehensive site evaluation or ACSCE during each report period

(July 1 – June 30). The evaluation is conducted a minimum of eight months and a maximum of sixteen

months from the previous Annual Evaluation. At a minimum, the Annual Evaluation consists of:

A review of all sampling, visual observations, and inspection records conducted during the previous reporting year

An inspection of all areas of industrial activity and associated potential pollutant sources for evidence of, or the potential for, pollutants entering the storm water conveyance system

An inspection of all drainage areas previously identified as having no exposure to industrial activities and materials in accordance with the definitions ins Section XVII of the General Permit

An inspection of equipment needed to implement the BMPs

An inspection of any BMPs

A review and effectiveness assessment of all BMPs for each area of industrial activity and associated potential pollutant sources to determine if the BMPs are properly designed, implemented, and are effective in reducing and preventing pollutants in industrial storm water discharges and authorized NSWDs

An assessment of any other factors needed to comply with the requirements in Section XVI.B of the General Permit

The Facility implements SWPPP revisions resulting from the ACSCE within 90 days of the evaluation.

8.10 PPT Member Assignments Monthly visual observations are carried out by the Site Engineer. Sampling and related visual

observations are also performed by the Site Engineer.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 35 Project No. 14-05406-20

9.0 MONITORING RECORDS AND REPORTING REQUIREMENTS Records of all monitoring and training are to be kept with this SWPPP and reports are submitted as

required in the General Permit.

9.1 Record Keeping All monitoring are properly documented on the appropriate example forms in this SWPPP (Appendix F

provides example templates of the below records) and maintained in Appendix H for a minimum of five (5)

years. Minimum records to be maintained are as follows:

SWPPP

Monthly Visual Observations – Non-Stormwater Discharge

Sampling Event Visual Observations – Stormwater Discharges

Annual Visual Observations – ACSCE

ACSCE Summary Report

Personnel Training

Significant Spills and Leaks

Documentation of Dangerous Weather Preventing Inspection or Sampling

9.2 Reporting Requirements The General Permit requires an annual report to be certified and submitted to the Regional Water Quality

Control Board (RWQCB) on the SMARTs website no later than July 15th following each reporting year

using the standardized format and checklists in SMARTS. The Annual Report, to be completed on

SMARTs website, includes:

A Compliance Checklist that indicates whether a Discharger complies with, and has addressed all applicable requirements of the General Permit;

An explanation for any non-compliance of requirements within the reporting year, as indicated in the Compliance Checklist;

An identification, including page numbers and/or sections, of all revisions made to the SWPPP within the reporting year; and,

The date(s) of the Annual Evaluation.

SWPPP No 20 El Sobrante Facility _audit update.docx

December 2014 36 Project No. 14-05406-20

10.0 REFERENCES Spill Prevention Control and Countermeasure Plan, prepared by WM (current version).

Hazardous Material Business Plan, prepared by WM (current version)

SWPPP No 20 El Sobrante Facility _audit update.docx

TABLES

FIGURES

APPENDIX A FUTURE SWPPP ADDENDA WITH ADDITIONAL/REVISED BMPS

APPENDIX B SWRCB WQO NO. 2014-0057-DWQ, NPDES GENERAL PERMIT NO. CAS000001, WDRS FOR DISCHARGES OF STORMWATER ASSOCIATED WITH INDUSTRIAL ACTIVITIES

(INCLUSIVE OF SUBMITTED PRD/NOI)

APPENDIX C CALIFORNIA 2010 INTEGRATED REPORT( 303(D) LIST/305(B) REPORT FOR LOMA ALTA

CREEK

APPENDIX D EMPLOYEE TRAINING RECORDS AND TRAINING DOCUMENTS

APPENDIX E SPILL RESPONSE PROCEDURES, SPILL GUIDE, LIST OF SIGNIFICANT SPILLS AND LEAKS

APPENDIX F EXAMPLE STORMWATER MONITORING AND REPORTING FORMS

APPENDIX G CALIFORNIA STORMWATER QUALITY ASSOCIATION (CASQA) BMP HANDBOOK FACT SHEETS

APPENDIX H INDUSTRIAL STORMWATER MONITORING AND SAMPLING GUIDE (EPA 832-B-09-003)

APPENDIX I PROGRAM COMPLIANCE DOCUMENTATION

(BOUND SEPARATELY)

Golder Associates Inc. 1000 Enterprise Way

Roseville, CA 95679 USA Tel: (916) 786-2424 Fax: (916) 786-2434

Golder, Golder Associates and the GA globe design are trademarks of Golder Associates Corporation

W-9 LFG Collection and Control System (GCCS) Exhibit

1460

1440

12501450

1460

1470

1460

1440

1340

1270

1290

1310

1330

1420

1150

1180

1200

1350

1450

1370

1290

1230

1250

1380

1380

1400

1420

1440

1390

1360

13501340

1080

1330

1380

1210

1410

1470

1480

1480

1300

1450

1460

1430

1440

1250

1450

1460

1390

1380

1340

1320

1320

1340

1330

1360

1360

1320

1290

1340

1400

1450

14

6014

80

1520

1500

1500

1460

14501440

1370

1330

1230

1210

1200

1400

1420

1410

1320

1330

134

0

1350

134

0

1370

1370

1360

1320 13

30

1310

1310

1290

1270

1310

1430

1400

1380

1300

1240

1260

1300

1280

1270

1210

1170

1330

1370

1370

1290 12

90

1340

1320

1310

13901

200

1070

1150

1120

1080

1260

1130

1170

1220

1390

1270

1300

1280

1130

1150

1110

1190

1230

1250

1350

1270

1120

1320

1170

1450

1470

1450

1430

1380

1360 134

0

1320

137014

10

1400

1380

1360

1390

1370

1360

1350

1340

1320

1100

1080

1090

121012

30

1310

1330

1300

1300

1310

1280

1330

1160

1220

1230

1210

1130

1190

1190

1190

1190

1190

1180

117

0

1170

1170

1170

1150

1150

1090

1090

1460

1360

1390

1430

1330

1440

1400

1380

1370

1370

1370

1370

1290

1310

1320

1350

1350

1350

1290

1290

128012

70

1260

1250

1250

1140

1240

1150

1150

1110

1110

1200

1300

1300

1300

1310

1320

1330

1330

1330

1270

1180

1310

1310

1310

1310

1320

1320

1360

1360

1360

1360

1360

1360

1360

1360

1360

1340

1340

1340

1340

1290

1290

1290

1330

1330

1330

1350

1350

1350

1350

1350

1350

1350

1350

1300

1140

1280

1270

1270

1270

1250

1250

1230

1160

11801160

1310

1310

1310

1450

1450

1430

1430

14

30

1430

1430

1430

1320

1320

1320

1320

1320

1320

1360

1360

1360

1360

1360

1320

1340

1340

1340

1340

1290

1330

1330

1330

1330

1330

1330

1330

1480

1520

1510

1510

1510

1490

1490

1490

1490

1490

1500

1500

1480

1480

1480

1480

1470

1470

1470

1470

1470

1460

14

60 1

460

1460

1460

1440

1440

1450

14

50

1450

14

40

1440

1440

1440

1440

1440

1420

1420

1420

1420

1420

1420

14

20

1420

1420

1410

1410

1410

1410

1410

1410

14

10

1420

1420

1420

1400

1400

1400

1400

1400

1400

1400

1400

1400

1400

1390

1390

1390

1390

1390

1390

1390

1390

1390

1380

1380

1380

1380

1380

1380

1380

1380

1370

1370

1370

1370

1370

1370

1370

1370

1370

1370

1350

1350

1350

1350

1350

1350

1350

1350

1350

1330

1310

1310

1310

1310

1310

1310

1310

1310

1300

1300

1300

1300

1300

1280

1280

1280

1260

1270

1270

1270

1270

1250

1250

1240

1240

1230

1230

1220

1220

1220

1200

1200

Pipe

Pipe

Pipe

Pipes

Pipes

Pipes

Pipe

Pipes

Pipes

Pipes Pipes

Pipe

Pipe

Pipe

Pipe

Pipes

Pipe

PipesPipes

Pipe

Conc

Parking

UnpavedPipes

Conc

1468.34

500R

W.L.

1079.0

Tanks

Rip Rap

W.L=

W.L=

W.L=

1292.1

1287.7

1297.8

Tank

Sign

Rocks

Rocks

Unpaved Parking

Pipes

Scale

Sign

Sign

Unpaved Parking

Paved

Parkin

g

ConcT

T

Scale

Scale

Conc

Conc

Conc

Conc

Sign

Pipe

Pipe

Conc

Pipes

Sign

Tanks

Pipe

PipePipe

Pipe

Pipe

Pipe

Sign

Sign

Sign

Sign

Sign

Sign

Sign

Sign

Sign

Pipes

Pipe

Pipe

Pipes

Pipes

Pipes

Pipes

Pipe

Pipe

Pipe

Pipe

Pipe

Pipe

Pipes

Pipes

Pipe

Pipe

Rocks

Pipe

Pipe

Pipe

Pipe

Pipe

Pipe

Pipe

Pipe

Rocks

Rocks

Tank

Rocks

Tarp

Pipe

Pipe

Rocks

Rocks

Rocks

Rocks

Rocks

Open Storage

Rocks

Rocks

Rocks

Rocks

Rocks

Rocks

Rocks

Rocks

Rocks

Rocks

Conc

Unpaved Parking

Pipe

Pipe

Pipe

Pipe

Pipe

Pipes

Pipe

Pipe

Pipe

Pipe

Pipes

Pipes

Pipes

Pipes

Pipes

Pipes

Pipes

Pipes

Pipes

Pipe

Pipe

Pipe

Pipes

Pipe

Pipes

Pipes

Rocks

Rocks

Pipe

Pipe

Pipes

Rocks

Rocks

Tank

Tarp

PHASE 10

PHASE 9B

PHASE 9A

7B

PHASE

PHASE 8

PHASE 2

STAGE 3A

PHASE 3

PHASE 1

PHASE 6

PHASE 11A

STAGE 2A

PHASE 4

STAGE 1

PHASE 4,

STAGE 3B &

PHASE 3

STAGE 1

PHASE 3

STAGE 2B

PHASE 4

7A

PHASE

STAGE 2A

PHASE 3

STAGE 2B

PHASE 3

STAGE 2

PHASE 3

12" HEADER AG

12" HEADER BG

10" HEADER AG

10" HEADER BG

8" LATERAL AG

8" LATERAL BG

6" LATERAL AG

6" LATERAL BG

3 OR 4" LATERAL AG

3 OR 4" LATERAL BG

18" HEADER AG

18" HEADER BG

24" HEADER AG

24" HEADER BG

HORIZONTAL COLLECTOR - SOLID

SITE SHALLOW WELL

HORIZONTAL COLLECTOR WELLHEAD

H2S TREATMENT VESSEL

WELL OFFLINE

ACTIVE WELLS

REMOTE WELLHEAD

SYMBOL LEGEND

VALVE

REMOTE WELLHEAD MANIFOLD

124

ROAD CROSSING

CONDENSATE SUMP

30" HEADER AG

30" HEADER BG

HORIZONTAL COLLECTOR - PERFORATED

REDUCER

COMPRESSED AIR

CONDENSATE FORCE MAIN

HORIZONTAL COLLECTOR - SOLID (EXISTING)

HORIZONTAL COLLECTOR - PERFORATED (EXISTING)

PP GAS COLLECTION FOR POWER PLANT

86

WELL WITH TEMP VARIANCE

MONITORING PROBE

GRAPHIC SCALE

SCALE IN FEET

CONSULTANT

DESIGN

PREPARED

REVIEW

APPROVED

YYYY-MM-DD TITLE

PROJECT No. Rev.

PROJECTCLIENT

IF T

HIS M

EA

SU

RE

ME

NT D

OE

S N

OT M

AT

CH W

HA

T IS S

HO

WN, T

HE S

HE

ET SIZ

E H

AS B

EE

N M

ODIFIE

D F

RO

M:

AN

SI

B

A

NSI_

B_

BA

SIC

_L

AN

DS

CA

PE_IM

P.d

wg

| File N

am

e:

----

Path:

01 in

1401287

FIGURE

1

2015-02-13

KJK

AW

WASTE MANAGEMENT INC.

EL SOBRANTE LANDFILL

5-YEAR CONCEPTUAL GCCS PLANS

(YEAR 2015)

EXISTING GCCS LAYOUT

0 400 800

RH

AW 0

JANUARY 15, 2015 AERIAL PHOTOGRAPHY.

MANAGEMENT. THE TOPOGRAPHY DATA IS BASED ON

EXISTING TOPOGRAPHIC PLAN IS FURNISHED BY WASTE

EW24S

EW18

EW27D/S

EW26D/S

CL- III/2-B2/3-

C1

CL- III/2-B1

6"

CL- I -A4

CL- I -V6

CL-I-V12

CL-I-V13

CL-I-V10

CL-I-V11

4"

GP-12R

EW25D/S

GP-1R

GP-10RR

GP-13

EW47D/S

EW46D/S

EW1

EW2

EW3

EW4

EW5

EW22S

EW21S

EW17D/SEW10

EW23D/S

EW9

EW8

EW16D/SEW7

EW6

EW14D/S

EW15D/S

EW19

EW20

EW30D/S

EW31S/D

EW35S/D

EW36S/D

GP-9R

GP-3R

CL-VII-B

3

GP-4T

CL-VIII-A5

CL-VIII-A4

24" F

L

18" P

P

24" F

L18"

24" F

L

18"

24" F

L

18" P

P

24" F

L

18" P

P

24" FL

18" PP

24" FL

18" PP

24"18"

24" F

L18" P

P 24"

18"

24" FL

18" PP

24"

18"

24" FL

18" PP

24"12"

24" FL12" PP 24"

24" FL

EW41S/D

EW42D/S

EW43D/S

EW49D

EW50D

GP-2A-R

SVE-1

6"

4"

6"

EW60

ELSW0234

ELSW0233

ELSW0231

ELSW0230

ELSW0232

30" FL

30" FL

30" FL

8"

8"

30" FL 30" FL

30" FL12" VERTICAL TEE

2:1

DRAINAGE V-DITCH

CROSSOVER

TRANSITION POINT-

8"F

L

12" PP

T-101 TANK

EW211D/S

EW210

EW209S/D

EW224D/S

EW223D/S

EW207

EW222D/S

EW218D/S

EW220D/S

EW243D/S

EW240D/S

EW244

195

187

195

187

238

82

83

84

88

87

86

178

910

8174

7

5

8"

8"

12"

T186

EW245

EW246

EW247

EW248

EW249

12

EW213D/S

EW215D/S

EW214

EW82

EW216D/S

EW217D/S

EW221D/S

EW212D/S

EW13S

EW1002

EW1001

EW1003

EW1106

EW1101

EW1103

EW1105

EW1102

EW1107

EW1108

12"

CS-4

CS-2

CS-3TANK FARM

POWER PLANT

FLARE 3

ELEV. 1304.9

BOTTOM OF FLANGE

PHASE 3 LEACHATE RISER EW1110 S/D

EW1111

EW1114

EW1113

8"

12"

18"

18"

8"

6"

EW1115

8"

6"FL

4"P

P

4"P

P

4"F

L

4"F

L

4"P

P

12"P

P

8"P

P

8"F

L

6"FL

6"FL

6"F

L

GP-8RR

GP-25

GP-24

GP-23

GP-6TP

GP-5TP

GP-4TP

GP-11R

EW1232 S/D

EW1233

EW1234

EW1235

EW1236

EW1227

EW1225

EW1223

EW1221S/D

EW1222S/D

EW1220

EW1224

EW1229

EW1228

EW1231

EW1226

8"

12"

8"

6"

12"

6"

6"

6"

6"

6"

EW1230

ELSWO237

P9A

P8A P8B

GP-10R3

EW1104

12"

18" PVC CAP

EW1241

H1351

EW1240

EW1242

H1350

H1352

H1353

H1354 H1355

6"

235

H09-1

400-0

0 E

L.1

404

H09-1

350-0

1 E

L. 1348

H09-1

350-0

2 E

L. 1343

H09-1

350-0

3 E

L. 1340

H09-1

350-0

4 E

L. 1345

H09-1

350-0

5 E

L. 1343

EL. 1340

H09-1

350-0

6

H09-1

400-0

1 E

L. 1408

H09-1

400-0

2 E

L. 1410

H09-1

400-0

3 E

L. 1413

H09-1

400-0

4 E

L. 1417

1392.44

T.O.P ELEV.

FLANGE

30" BLIND

SUMP CS-5

CONDENSATE

ELEV. 1322.0

TOP OF LID

SUMP CS-1

CONDENSATE

ELEV. 1261.0

BOTTOM OF FLANGE

LEACHATE RISER

PHASE 8

T.O.P ELEV 1304.35

30" FLANGE CONN.

LEACHATE SUMP

PHASE 7 NORTH

LEACHATE SUMP

PHASE 7 CENTER

CROSSOVER

TRANSITION POINT-

ELEV. 1378.7

BOTTOM OF FLANGE

PHASE 9 LEACHATE RISER

H09-1

400-0

5 E

L. 14xx

EW1430

EW1431

EW1432

EW1433

EW1434

EW1435

EW1436

EW1437

EW1438

6"

6"

6"

SVE-2SVE-3

SVE-4 SVE-5

SVE-6

8"

8"

6"

6"

8"