cm2355 skf condition monitoring essentials
DESCRIPTION
skf cmTRANSCRIPT
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
1/40
SKF Junction Boxesand Enclosures
SKF MicroTempThermometer
CMSS 2020-SL
SKF Vibration Penplus
CMVP 40/CMVP 50
SKF Inspector 400Ultrasonic Probe
CMIN 400-K
SKF InfraredThermometer
CMSS 3000-SL
SKF Machine ConditionDetector Pro ISCMVL 3600-IS
SKF MicroVibe PCMVL 3850-ML
SKF CMSS 2100 GeneralPurpose Industrial
Accelerometer
SKF CMSS 2200/CMSS 2200-M8
General Purpose LowProfile IndustrialAccelerometer
SKF Cable Assemblies
SKF Loop-powerdVibration
Transmitters seriesCMSS 420VT
SKF Temperature ProbeCMSS 2000-SL
SKF Machine ConditionAdvisor CMAS 100-SL
SKF Basic ConditionMonitoring KitCMPK 200plus/CMPK 210plus
SKF Bearing Analysis KitCMPK 60plus/CMPK 70plus
SKF Reliability Systems standard product offering:
SKF Reliability Systems
condition monitoringessentials
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
2/40
Description Page
Introduction 3
SKF Machine Condition Advisor CMAS 100-SL 4
SKF Infrared Thermometer CMSS 3000-SL 8
SKF Inspector 400 Ultrasonic Probe CMIN 400-K 10
SKF Machine Condition Detector Pro IS CMVL 3600-IS Machine Reliability Inspection System Intrinsically Safety (IS) rated
13
SKF MicroVibe P CMVL 3850-ML 16
SKF Loop-powered Vibration Transmitters series CMSS 420VT 20
SKF CMSS 2100 General Purpose Industrial Accelerometer 22
SKF CMSS 2200/CMSS 2208-M8 General Purpose Low Profile Industrial Accelerometer 23
SKF Single/Double Shield Twisted Pair Cables CMSS 9100/CMSS 9200 24
SKF Cable Assembly IP 68 CMSS R6Q(I)-9100-XX 25
SKF Cable Assembly IP 66 CMSS R6SL(I)-9100-XX 25
SKF Junction Boxes and Enclosures 26
CMSS 260 NEMA 4 and NEMA 4X Enclosures 27
CMSS 265 series Termination Junction Boxes 28
CMSS 300 series BNC Junction Boxes 29
CMSS 310 series Switchable BNC Junction Boxes 31
SKF Vibration PenplusCMVP 40 english system (in/s; equivalent Peak)/CMVP 50 metric system (mm/s; RMS) 33
SKF Temperature Probe CMSS 2000-SL 35
SKF MicroTemp Non-contact Thermometer CMSS 2020-SL 37
SKF Basic Condition Monitoring Kit CMPK 200plusmetric system/CMPK 210plusenglish system 38
SKF Bearing Analysis Kit CMPK 60plusmetric system/CMPK 70plusenglish system 39
Product Support Plans (PSP)Backcover
Table of contents
2
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
3/40
Introduction
Global presence localsolutions
With over 100 years of experience, SKF stands
alone as a total solution provider for maximizingmachine and plant productivity. With a
reputation for quality, technological innovation
and service that spans the globe, SKF brings
what no other vendor can to the maintenance
arena.
Local SKF sales and service representatives
and worldwide distributors provide access to
the range of SKF bearings, maintenance
products, lubricants and condition monitoring
instrumentation and software, independent of
your location.
In any kind of rotating machinery, from hugerolling machines to the smallest of motors, the
bearing knows if there is a potential problem.
As the primary interface between moving parts,
the bearing is literally the diagnostic heart of
the machine.
Misalignment, unbalance, looseness and
friction, are all telegraphed through the
bearing. Understanding the information
coming from this diagnostic pulse and then
applying the latest and best technology to the
problem is the key to raising machine
productivity and lowering operating costs.
This SKF Reliability Systems conditionmonitoring essentials product catalogue
features a convenient collection of monitoring
tools that no industrial manufacturing plant
should be without.
3
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
4/40
SKF Machine Condition AdvisorCMAS 100-SL
Machine monitoring, made simple
Introduction
Now both novice users and experts can
easily, quickly and accurately check the
condition of rotating equipment throughout
your facility. Equipping your maintenance
and operations personnel with this rugged,
ergonomic and easy-to-use instrument can
provide early warning of potential machine
problems before a costly failure occurs.
Multiple measurements with a single
device
The SKF Machine Condition Advisor provides
an overall Velocity vibration reading that
measures vibration signals from the
machine and automatically compares them
to pre-programmed International
Organization for Standardization (ISO)
guidelines. An Alert or Danger alarm
displays when measurements exceed those
guidelines. Simultaneously an Enveloped
Acceleration measurement is taken and
compared to established bearing vibration
guidelines to verify conformity or indicate
potential bearing damage.The SKF Machine Condition Advisor also
measures temperature using an infrared
sensor to indicate uncharacteristic heat.
Features
Quick and easy to set up and use,
measurements are shown on a bright
display viewable in low light to direct
sunlight. Free on-line training is also
available at SKF @ptitude Exchange.
Lightweight, compact and ergonomically
designed, the SKF Machine Condition
Advisor fits neatly at the belt line, in a
pocket or a tool kit. Exceptionally durable,
the unit is rated IP 54 for use in adverse
industrial environments.Alert and Danger prompts provide
increased diagnostic confidence.
SKF Machine Condition Advisor simultaneouslymeasures vibration signals and temperature toindicate machine health or bearing damage.
Measuring Velocity, Enveloped
Acceleration and temperature
simultaneously saves time.
Efficient, economical and environmentally
friendly, the rechargeable SKF Machine
Condition Advisor operates 10 hours on a
single charge.
Flexible enough to work with standard
100 mV/g ICP accelerometers, an optional
external sensor can be used for hard-to-
reach locations.Features English, French, German,
Portuguese, Spanish and Swedish for
user convenience.
4
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
5/40
Accuracy, flexibility and confidence
When performing measurements, the SKF
Machine Condition Advisors acceleration
sensor input signal is processed to produce
two different measurements for each POINT
on the machinery overall velocity andenveloped acceleration. At the same time,
the SKF Machine Condition Advisors non-
contact infrared sensor measures the
surface temperature of the measurement
location and simultaneously displays all
three measurement values.
LCD display in measurement mode
ISO machinegroup
EnvelopedAcceleration
class
Batteryindicator(60% full)
Measurementstatus
Temperature
EnvelopedAcceleration Velocity
Alarm display:(A) Alert or(D) Danger
Selectbutton
Browsebutton
Specifications
Vibration pickup:
Internal: Integrated piezoelectric
acceleration
External: Accepts ICP type 100 mV/g
accelerometer
Temperature sensor: Internal IR
temperature sensor
Measurements:
Velocity:
Range: 0.765 mm/s (RMS),
0.043.60 in/s (equivalent Peak),
meets ISO 10816
Frequency: 101 000 Hz, meets
ISO 2954
Enveloped acceleration:
Range: 0.250.0 gE
Frequency: Band 3 (50010 000 Hz)
Weight: 125 g (4.4 oz)
Dimensions:
Length: 200 mm (7.90 in)
Width: 47 mm (1.85 in)
Height: 25.4 mm (1.00 in)
Battery capacity: 550 mA hours
Battery life: 10 hours before charging
again (1 000 measurements)With external sensor: Up to 55 % less
battery life
Supported external sensor: Any standard
accelerometer with 100 mV/g sensitivity
that needs ICP (Integrated circuit-
piezoelectric)
External sensor power: 24 V DC at 3.5 mA
Charger specifications:
Universal AC/DC wall plug-in
Input: 90264 VAC, 4760 Hz
Output: 5 V DC regulated
3 to 4 hours for a full charge
Temperature:
Range: 20 to +200 C (4 to
+392 F)
IR temperature accuracy: 2 C
(3.6 F)
Distance: Short range, maximum
10 cm (4 in) from target
Operating temperature range:
In use: 10 to +60 C (+14 to +140 F)
While charging: 0 to +40 C (+32 to
+104 F)
Storage temperature:
Less than one month: 20 to +45 C
(4 to +113 F)
More than one month but less than six
months: 20 to +35 C (4 to +95 F)
Humidity: 95 % relative humidity,
non-condensing
Enclosure: IP 54
Approvals: CE
Drop test: 2 m (6.6 ft)
SKF Machine Condition Advisor CMAS 100-SL
Depending on the SKF Machine Condition
Advisors System setting, the front-panel
LCD simultaneously displays:
Units in Metric or EnglishVelocity in mm/s RMS or IPS derived Peak
Temperature in Celsius or Fahrenheit
Acceleration enveloping readings in gE
Quick and easy first time and every time
Press Select or Browse button to turn1
the SKF Machine Condition Advisor On
Press the sensor tip against the point to2
be measured
When the readings stabilize, press the3Select button to hold the reading
Read and record the measurement values4
5
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
6/40
Understanding and using guidelines for
vibration
The SKF Machine Condition Advisor provides
a means to evaluate machine health based
on ISO 10816-3 and to evaluate the
bearings according to general guidelinesdeveloped from a statistical analysis of
existing databases.
How to choose the correct Alarm Velocity
Group for your machinery
The Alarm Velocity Group (G2&4or G1&3)
determines the instruments overall
vibration alarm limits. Therefore, select the
Group that best describes the general size,
type, and speed of the machinery being
measured. Note that these machine group
classifications are set forth in ISO 10816-3,which rates overall velocity vibration levels
for standardized machinery classifications.
Groups 2&4 (default)
ISO Group 2 and 4 classifications define the
following type of machinery:
Medium-sized machines and electrical
machines with a shaft height between
160 and 315 mm.
These machines are normally equipped
with rolling element bearings, but may
use sleeve bearings, and operate atspeeds above 600 RPM.
These machines include pumps with
multi-vane impellers and integrated
drivers.
Groups 1&3
ISO Group 1 and 3 classifications define the
following type of machinery:
Large machinery and electrical machines
with a shaft height greater than 315 mm.
These machines are generally equipped
with sleeve bearings, but may use rolling
element bearings.
These machines include pumps with multi-
vane impellers and integrated drivers.
Rigid or Flexible foundation?
An additional setting allows the specification
(when defining the overall alarm levels) of
measurements taken from machinery with
Rigid(default) or Flexiblefoundations.
Options are:
G2&4R (default)
Alert: 2.8 mm/s (0.16 ips)
Danger: 4.5 mm/s (0.25 ips)
G2&4F
Alert: 4.5 mm/s (0.25 ips)
Danger: 7.1 mm/s (0.39 ips)
G1&3R
Alert: 4.5 mm/s (0.25 ips)Danger: 7.1 mm/s (0.39 ips)
G1&3F
Alert: 7.1 mm/s (0.39 ips)
Danger: 11.0 mm/s (0.61 ips)
SKF Machine Condition Advisor CMAS 100-SL
How to choose the correct Enveloped
Acceleration Classification for your
machinery
The Enveloped Acceleration Classification
(CL1, CL2,or CL3) you specify determines
the instruments bearing vibration alarmlevels. Therefore, the Enveloped Acceleration
Class that best describes the general size
and speed of the bearings being measured
should be selected.
Options are:
CL1
Bearings with a bearing bore diameter
between 200 and 500 mm and a shaft
speed below 500 RPM.
Alert: 1 gEDanger: 2 gE
CL2 (default)
Bearings with a bearing bore diameter
between 200 and 300 mm and a shaft
speed between 500 and 1 800 RPM.
Alert: 2 gE
Danger: 4 gE
CL3
Bearings with a bearing bore diameter
between 20 and 150 mm and a shaft speed
from 1 800 to 3 600 RPM.Alert: 4 gE
Danger: 10 gE
6
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
7/40
Specifications (Accelerometer)
Dynamic performanceSensitivity (10 %): 10.2 mV/(m/s 2)
(100 mV/g)
Measurement range: 490 m/s 2(50 g)
Frequency range (3 dB): 0.3210 kHz
Mounted resonant frequency: 22 kHz
Amptitude linearity: 1 %
Transverse sensitivity: 7 %
Electrical
Settling time: 2 sec
Excitation voltage: 1830 VDC
Excitation constant current: 220 mA Output impedance: 10 8
Electrical protection: RFI/ESD
Integral cable: 22 AWG, +105 C
(22 AWG, +221 F)
Environmental
Shock limit: 49 km/s 2pk (5 000 g pk)
Temperature range: 54 to +85 C
(65 to +185 F)
Spectral Noise
10 Hz: 78.5 (mm/s 2)/Hz (8 g/Hz)
100 Hz: 49.1 (mm/s 2)/Hz (5 g/Hz)
1 kHz: 39.2 (mm/s 2
)/Hz (4 g/Hz)
Mechanical
Size: 12.70 x 26.67 mm (0.50 x 1.05 in.)
Weight (including 1.5 meter cable): 70.7 g
(2.5 oz)
Mounting thread: 1/4-28 UNF-2B
Mounting torque: 2.7 to 6.8 N-m (2 to 5
ft-lb)
Sensing element: Ceramic/shear
Case material: Stainless steel
Sealing: Potted
Wrench flats: 7/16"
Ordering information
SKF Machine Condition Advisor
CMAS 100-SL includes:
SKF Machine Condition Advisor unit
Belt holster [CMAC 102]Charger, international DC power supply
[CMAC 8002]
Charger adapter, cable [CMAC 101]
User manual, English hard copy
[32131800-EN]
CD containing:
User manual available in PDF files in
English, French, German, Portuguese,
Spanish, and Swedish
Link to training on SKF @ptitude
Exchange
SKF Machine Condition Advisor trend
worksheet (Excel .xls file)
SKF Reliability Systems Condition
Monitoring Essentials catalog available
in PDF file in English [CM2355]
CD, Integrating Condition Monitoring
Products and Asset Management
Services, product catalog [CM5057]
Accessories
Extension kit, 100 mV/g accelerometer
with 1.5 m integral cable and magnet
[CMAC 105]
Connection cable, 1.5 m with M8 sockettype connector for standard ICP 100 mV/g
accelerometer (ICP: integrated circuit
piezoelectric) [CMAC 107]
Replacement
Charger adapter, cable 4 inches,
connector to 5.5 mm power [CMAC 101]
Charger, international DC power supply,
+5 V, 1 600 mA, 90264 VAC, 4763 Hz
[CMAC 8002]
Magnet, magnet base, 0,75 diameter, 10
lbs pull-strength [CMAC 106]Belt holster [CMAC 102]
Optional kits that includes the SKF
Machine Condition Advisor, CMAS 100-SL
SKF Basic Condition Monitoring kit
[CMAK 400]
SKF Bearing Analysis kit [CMAK 300]
Typical sensitivity deviation vs. temperature
Sensitivity
Deviation
(%)
Temperature, C (F)
73 18 +38 +93 +149(100) (0) (+100) (+200) (+300)
+20
+10
0
10
20
SKF Machine Condition Advisor CMAS 100-SL
Expanding your capabilities with SKF Machine Condition Advisor compatible
accessories
External sensor kit Model CMAC 105
The Extension sensor kit CMAC 105
contains an accelerometer with integralcable and everything needed to take
measurements from hard-to-reach places.
Accelerometer
100 mV/g sensitivity
Small size case, 0.5 x 1.05
Small footprint, 0.5
0.32 Hz to 10 kHz frequency range
(3 dB)
Waterproof
Integral cable (1.5 meters)
Connector to SKF Machine Condition
Advisor CMAS 100-SL
Magnet, Model CMAC 106
10 lbs pull-strength, 0.75" diameter
Each accelerometer is fully enclosed in a
potted and waterproof stainless steel case.
Connection cable (1.5 meters) Model
CMAC 107
Optional Connection cable for standard ICP
accelerometers with 100 mV/g, mil-spec
connector.
7
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
8/40
LCD display
Dual laser sighting and distance to spot
ratio
Dual Lasers provides easy aiming and
defines the target area. The target area ishighlighted at all distances with two laser
dot markers. Laser 1 indicates one point of
the measurement spot on one side of the
target area to be measured and Laser 2
indicates the location of the diametrically
opposed point on the other side of the
measurement spot. At the focal point, where
the spot size is the smallest, the dots line up
vertically, rotating as the SKF Infrared
Thermometer is moved closer or further
from the target.
Distance to spot ratio 50:1.
SKF Infrared ThermometerCMSS 3000-SL
Heavy duty, long range, dual laser sighted non-contact infrared thermometer
Features
Dual point laser sighting
Adjustable emissivity
50:1 Distance to spot size ratio
Temperature range: 60 to +1 000 C
(76 to +1 832 F)
Exceptional battery life
High and low alarm
MAX, MIN, DIF, AVG temperature displays
Amber back-light LCD display
High intensity white LED flashlight
Heavy duty magnet in base of handle Hard case
Introduction
There are many uses for this hand-held
non-contact, infrared thermometer. Rugged
and easy to use just aim, pull the trigger,
and read the temperature in less than a
second. Measures surface temperatures of
hot, hazardous, moving, or hard-to-reach
objects safely without contact.
The non-contact thermometer senses the
thermal energy radiated from an object with
an infrared detector. When pointed at anobject, the infrared detector collects energy
producing a signal that the microprocessor
translates as a reading on the backlit display.
As the trigger is squeezed, the object
temperature is continuously measured by
the infrared detector. This allows for fast and
accurate real-time readings.
This instrument features an extended
temperature range 60 to +1 000 C (76
to +1 832 F); dual laser sighting; bright
large amber back-light LCD display;
Maximum, Minimum, Difference (MAX-MIN)and Lock function for continuous
temperature scanning; programmable High
and Low audible alarms; selectable
temperature units (C or F); low battery
indicator and adjustable emissivity for more
accurate temperature measurements.
Emissivity
Lock functionfor continuous
temperaturescanning
Laser functionON/OFF
Surfacetemperature
Set valueof emissivity
Selectedtemperature unit(degrees Celsius/Fahrenheit)
Battery lowindicator
Scanningin progress
EmissivityEmissivity is a term used to describe the
energy-emitting characteristics of materials.
Most organic materials and painted or
oxidized surfaces have an emissivity of 0.95.
Inaccurate readings can result from
measuring shiny or polished metal surfaces.
To compensate for this, adjust the units
emissivity reading, or cover the surface to be
measured with masking tape or flat black
paint (< +148 C /+300 F). Allow time for
the tape or paint to reach the same
temperature as the material underneath it.Measure the temperature of the tape or
painted surface.
Hard case
A water resistant, dust-proof case which
holds the unit (and magnetic stand) and
measures 330 x 197 x 66 mm (13.00 x
7.75 x 2.60 in.) is included.
2.4 in. at120 in.
Target area
Laser 2Laser 1
Focal point
1.6 in. at80 in.
0.04 mat 2 m0.06 m
at 3 m
8
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
9/40
Specification
Measurement range: 60 to +1 000 C
(76 to +1 832F)
Operating range: 0 to +50 C (+32 to
+122 F)
Accuracy (T object= 15-35 C, Tambient=25 C): 1.0 C (1.8 F)
Accuracy (T object=33-1,000 C; Tambient=
23 3 C): 2 % of reading or +2 C
(+4F) whichever is greater
Update frequency: 1.4 Hz
Wave length response: 8-14 m
Emissivity range: 0.95 default
adjustable 0.1 to 1 step .01
Relative humidity: 5 to 95 %
non-condensing
Resolution (from -9.9 to +199.9 C):
0.1 C /0.1 FResponse time (90 %):
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
10/40
Features
Detect pressure and vacuum leaks
including compressed air
Check steam traps and valves quickly and
accurately
Detect arcing, tracking and corona in
electric apparatus
Test bearings, pumps, motors,
compressors, etc.
Introduction
The SKF Inspector 400 Ultrasonic Probesenses high frequency sounds produced by
operating equipment, leaks and electrical
discharges. It electronically translates these
signals by a heterodyning process, making
them audible, so that a user can hear these
sounds through a headset and see them as
intensity increments on a meter.
The SKF Inspector 400 Ultrasonic Probe
can complement your condition
monitoring program by providing you with
the following capabilities:
Pressure/vacuum leaks
As any gas (air, oxygen, nitrogen, etc.)
passes through a leak orifice, it generates a
turbulent flow with detectable high
frequency components. By scanning the
test area with the SKF Inspector 400
Ultrasonic Probe, a leak can be heard
through the headset as a rushing sound or
noted on the meter bar graph indicator. The
closer the instrument is to the leak, the
louder the rushing sound and the higher
the meter reading. Should ambient noise be
a problem, a rubber focusing probe may beused to narrow the instruments reception
field and to shield it from conflicting ultra
sounds.
Valve
Valve activity such as leakage or blockage
can be accurately checked while the valve is
on line. Properly seated valves are relatively
quiet while leaking valves produce a
turbulent flow as the fluid moves from the
high pressure side through the leak to the
low pressure side. Due to a wide sensitivity
SKF Inspector 400 Ultrasonic ProbeCMIN 400-K
and ultrasonic frequency, all
types of valves even in noisy
environments can be accurately tested.
Valve stems
Valve stems may be quickly tested for leaks
to atmosphere.
Steam trap inspection
Major steam trap manufacturers have
recommended ultra sound inspection of
steam traps as one of the most reliablemethods available. By converting theultrasonic elements of a working steam trap
into the audible range, the SKF Inspector
400 Ultrasonic Probe allows users to hear
through headphones and see on a meter
the exact condition of a steam trap while it
is on line. Blowby, machine gunning,
oversized traps or line blockage are all
easily detected.
The SKF Inspector 400 Ultrasonic Probe
markedly reduces confusion from
extraneous sounds or from heat transfer,
even when traps are extremely closetogether.
Electrical inspection
Arcing and corona discharge emit ultra
sounds at the site of emission. This
electrical discharge can be located quickly
by scanning the area with the SKF Inspector
400 Ultrasonic Probe. The signal is heard as
a frying or buzzing sound in the headset. As
Valve leakage. Pressure/vacuum leaks.
with pressure or vacuum leak detection, the
closer the instrument is to the discharge,
the more intense the signal.
Test switch gear, transformers, circuitbreakers, buss bars, relays, junction boxes,
insulators, and other electrical gear.
General mechanical inspection
The SKF Inspector 400 Ultrasonic Probe
can detect the early stage of a machines
mechanical malfunction. NASA research
has demonstrated that ultrasound
monitoring will locate potential bearing
10
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
11/40
Mechanical inspection.
Heat exchangers, boilers and condensers
In-leakage or pressure leakage can be
readily located with the SKF Inspector 400
Ultrasonic Probe. Fittings, valves, flanges
are all easily scanned for leakage. The high
frequency, short wave nature of ultrasoundallows operators to pinpoint the location of
a leak in high noise environments.
Condenser tubes and heat exchanger
tubes may be tested for leakage through
two (2) methods: Vacuum and Pressure.
Vacuum
The tube sheet is scanned for the telltale
rushing sound produced as the leak draws
air into the tube.
Pressure
Additional testing may be performed when
the system is off-line utilizing air pressure
around the tube bundle and scanning for
the rushing sound produced from the
leaking tube.
Applications
Pressure and vacuum leak detection
Valve seat leak detection
Exhaust system leaks
Heat exchangers, boilers, condensers
Steam trap inspection
Bearing testingGear/gear box inspection
General mechanical inspection and
troubleshooting
Tanks, pipes, etc., leak testing
SKF Inspector 400 Ultrasonic Probe CMIN 400-K
deficiencies before they are detected by the
traditional heat and vibration methods.
With the SKF Inspector 400 Ultrasonic
Probe, users hear the sound quality of a
bearing as well as monitor amplitude
changes on the meter. This complementsother monitoring instruments and adds to
the ability to trend, troubleshoot and
confirm potential bearing problems.
General mechanical inspection is easy with
the SKF Inspector 400 Ultrasonic Probe and
with very little training, users can learn to
test bearings within minutes. Current
vibration programs can achieve enhanced
diagnostic ability with the SKF Inspector
400 Ultrasonic Probe.
Prevent over-lubrication with the SKF
Inspector 400 Ultrasonic Probe by simplylubricating only until the meter reaches a
specified level. Over lubrication is one of the
more common causes of bearing failure.
General mechanical inspection of pumps,
motors, compressors, gears and gear
boxes: All types of operating equipment
may be inspected with the SKF Inspector
400 Ultrasonic Probe. Since the SKF
Inspector 400 Ultrasonic Probe works in a
high frequency, short wave environment,
problems such as cavitation in pumps,
compressor valve leakage or missing gear
teeth may be heard and isolated.Reciprocating compressor valve analysis
has also become successful with the SKF
Inspector 400 Ultrasonic Probe and
therefore many engine analyzer companies
now offer instruments with an ultrasonic
input port.
Tank leakage.
Available SKF Inspector 400 Ultrasonic
Probe Stethoscope/Scanner kit includes:
SKF Inspector 400 Ultrasonic Probe
pistol housing with LED bar graph meter,
8-position sensitivity selection, low
battery indicator
Scanning module
Rubber focusing probe
Stethoscope module
Lightweight foam lined headset
9 volt alkaline battery (replaceable)
Cordura/nylon soft pack carrying case
Comprehensive instruction manual
(English language)
11
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
12/40
Ordering information
SKF Inspector 400 Ultrasonic Probe
Stethoscope/Scanner Kit [CMIN 400-K]
Accessories and replacement parts
Lightweight foam lined headset[CMAC 8600-1]
Deluxe noise isolating headphones
[CMAC 8600-2]
Deluxe noise isolating headphones to be
worn with hard hat [CMAC 8600-3]
Utility belt with holster [CMAC 8600-4]
Patented liquid leak amplifier, case of 12 x
8 oz bottles, (used for extremely low level
leaks 1 x 10-6mil/sec) [CMAC 8600-5]
Stainless steel unisonic scanning module
[CMAC 8600-6]
Stainless steel stethoscope/contact module [CMAC 8600-7]
Stethoscope extension rods
[CMAC 8600-8]
Rubber focusing probe [CMAC 8600-9]
SKF Inspector 400 Ultrasonic Probe CMIN 400-K
Specifications
Construction: Hand-held ABS pistol type
ultrasonic processor, stainless steel
sensor enclosures
Circuitry: SMD/solid state hybrid
heterodyne receiverFrequency response: 20-100 kHz
(centered at 38-42 kHz)
Indicator: 10 segment LED bar graph
(red)
Sensitivity selection: 8-position precision
attenuation
Power: 9 volt alkaline battery
Low battery voltage indicator: LED
Headset: Lightweight foam lined double
headset wired monophonic impedance;
16 ohms
Probes: Scanning module stainless steel unisonic (single transducer) piezoelectric
crystal type; stethoscope/contact module
stainless steel plug-in type with 5.5 inch
stainless steel waveguide
Rubber focusing probe: Shields stray
ultrasonic signals and focuses detected
signals
Response time: 300 millisec
Ambient operating temperature range:
0 to +50 C (+32 to +120 F)
Relative humidity: 10 to 95 %
noncondensing at up to +30 C (+86 F)
Storage temperature: 18 to +54 C(0 to +130 F)
Dimensions:
Height: 133 mm (5.25 in.)
Width: 50 mm (2.00 in.)
Length: 203 mm (8.00 in.)
Weight: 320 g (11 oz)
Carrying case: Cordura/nylon soft pack
with die cut foam
Optional kits that includes the SKF
Inspector 400 Ultrasonic Probe
CMIN 400-K
SKF Basic Condition Monitoring kit
[CMAK 400]SKF Machine Condition Advisor
[CMAS 100-SL]
SKF Infrared Thermometer
[CMSS 3000-SL]
SKF Inspector Ultrasonic Probe
[CMIN 400]
SKF Basic Condition Monitoring Kit
(metric system) [CMPK 200plus]
SKF Vibration Pen plus[CMVP 50-EN]
SKF Infrared MicroTemp Non-contact
Thermometer [CMSS 2020-SL]
SKF Inspector Ultrasonic Probe
[CMIN 400-K]
Basic Condition Monitoring Kit (english
system) [CMPK 210plus]
SKF Vibration Pen plus[CMVP 40-EN]
SKF Infrared MicroTemp Non-contact
Thermometer [CMSS 2020-SL]
SKF Inspector Ultrasonic Probe
[CMIN 400-K]
12
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
13/40
ATEX APPROVEDThe SKF Machine Condition Detector Pro IS provides for velocity, enveloped acceleration, andtemperature monitoring with general alarm capabilities and has ATEX Certifications.
identifies phenomena which are observable
in the low to mid frequency range, and
indicates such structural problems asmisalignment, unbalance, mechanical
looseness and more. However, events
which occur in the higher frequency ranges
such as bearing and gear problems, can
also be detected by the SKF Machine
Condition Detector Pro IS with its
Acceleration Enveloping capability, a signal
processing technique which focuses on
enhancing the repetitious vibration signals
that characterize such problems.
Temperature
Temperature measurements enhance the
early warning benefit of the instrument by
offering a useful indication of mechanical
condition or the load applied to a specific
component, since, as a bearing or its
lubrication fails, friction causes its
temperature to rise.
The SKF Machine Condition Detector Pro IS
is certified Intrinsically Safe (IS) for Europe
and North America. The ruggedized SKF
Machine Condition Detector Pro IS is ideal
for use in the hazardous environments
typically found in the petrochemical
Industrial marketplace.
Go / No Go machine monitoring
The SKF Machine Condition Detector Pro IS
is designed to provide a straightforward
approach to machinery monitoring. Theinstruments sensor affixes to a machine
point via a SKF MARLIN QuickConnect Stud
or magnetic bases for automatic collection
of vibration and temperature data. Green,
yellow and red LEDs provide easy-to-
interpret indications of machine status, so
operations or maintenance personnel can
quickly identify the need for more in-depth
analysis on a particular machine.
Multi-parameter monitoring capabilities
The SKF Machine Condition Detector Pro IS
operates as a stand-alone device, or as anaccessory to the SKF MARLIN hand-held
mobile computers for Operator Driven
Reliability (ODR). When used with SKF
@ptitude Inspector companion software
and the SKF MARLIN QuickConnect line of
mechanical and computerized studs, the
complete system offers customers in non-
hazardous conditions the added power and
functionality of immediate in-the-field
feedback on alarm conditions, as well as
data storage, trending and analysis. Data is
logged for trending, Statistical ProcessControl (SPC) rule violation, and percent
change from last measurement and
baseline data.
SKF Operator Driven Reliability
(ODR) process ensures that operator
observations are accurately, thoroughly, andconsistently recorded and communicated.
Utilizing automated technology that is
linked to your maintenance strategy,
operators immediately respond to abnormal
process conditions, proactively, with in-the-
field corrective actions that help increase
production output. In the event of
degrading asset health, operators can
initiate work notifications to your
computerized maintenance management
system (CMMS), providing enhanced
awareness to maintenance management.
Vibration monitoring
When performing measurements, the SKF
Machine Condition Detector Pro ISs sensor
input signal is processed to produce two
vibration measurements for each
measurement POINT. Velocity vibration
ATEX
SKF MARLIN Condition Detector Pro ISCMVL 3600-IS
Machine Reliability Inspection System, Intrinsically Safety (IS) rated
13
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
14/40
SKF MARLIN Condition Detector Pro IS CMVL 3600-IS
General alarm capabilities
When used as a stand-alone tool, the SKF
Machine Condition Detector Pro IS may be
easily programmed for six alarm settings,
which include the alert and danger levels
for each of the three measurements. Whenmeasurements are taken, current
measured values are automatically
compared to six user-defined settings, and
the SKF Machine Condition Detector Pro ISs
alarm indicator and LED react appropriately.
An alert condition provides a user with an
early warning of impending problems for
which immediate in depth analysis should
be performed. A danger alarm indicates
that a problem has escalated to a point
where actions must be made quickly to
avoid a serious failure.
SKF MARLIN QuickConnect studs for
quality, repeatable data collection
Specially designed mechanical and
computerized studs enable one or several
users to collect consistent, accurate, and
repeatable data from each measurement
point. Engineered to work exclusively with
the SKF Machine Condition Detector Pro IS,
the SKF MARLIN QuickConnect mechanical/
computerized studs provide for a fast,
quarter turn connection which temporarily
fastens the probe to a measurement point.This reduces the possibility of errors and
inconsistencies often resulting from data
collected by a variety of individuals using
varying methodologies.
Specifications
Measurements
Vibration pickup: Integrated piezoelectric
acceleration (ceramic, shear type)
Measurement range:Velocity: 0.355 mm/s (RMS), 0.02
3.00 in/s (equivalent Peak). Meets
ISO Standard 10816-1.
Enveloped acceleration: 0.320.0 gE
Temperature: 0 to +100 C (+32 to
+212 F)
Frequency range:
Overall velocity: 10 Hz1 kHz
(Tolerances measured within the
frequency range are in accordance
with ISO 3945)
Enveloped acceleration band 3:
500 Hz10 kHz
Display
Viewing area: 54.99 x 17.78 mm
(2.165 x 0.700 in.)
Power
Main power: Two (2) 1.5 V alkaline AA
batteries
Battery lifetime: 30 hours
Backup battery: One (1) 3 V BR1225
Lithium ion battery
Auto off: Two (2) minute countdown onlast operation
Hazardous area ratings
Intrinsic Safety (IS):
ATEX: II1G EEx ia IIC T4
(Ta = 20 to +40 C)
Class I, Division 1, Groups A, B, C, D
T3A (USA, Canada)
Physical characteristics
Case: Water and dust resistant (IP 65)
Drop test: Six (6) feet on multiple axes
Dimensions:Length: 190.5 mm (7.50 in.)
Width: 43.2 mm (1.70 in.)
Height: 41.4 mm (1.63 in.)
Weight: 431 gms (0.95 lb) with battery,
635 gms (1.4 lb) with temperature
magnet probe tip
User environment
Operating temperature:
20 to +60 C (4 to +140 F) ordinary
locations
20 to +40 C (4 to +104 F)
hazardous locations
Storage temperature: 37 to +70 C (34
to +158 F)
Humidity: 5 to 95 % noncondensing
Communications port
Type: Micro D RS-232
QuickConnect interface
Receptacle: 1/4 turn 5/8-24 two (2) lead
thread with contact
Accessories to fit:
SKF MARLIN QuickConnect:
QuickConnect Stud series
CMSS 26xx Temperature Magnet
10 cm (4) Stinger: CMSS 60139-04
14
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
15/40
SKF MARLIN Condition Detector Pro IS CMVL 3600-IS
Ordering information
SKF Machine Condition Detector MCD
Pro IS
SKF Machine Condition DetectorCMVL 3600-IS-K-01-C Kit
Each CMVL 3600-IS-K-01-C Kit consists of
the following items:
SKF Machine Condition Detector Pro IS
probe [CMVL 3600-IS]
SKF MARLIN QuickConnect 1/4-28 stud,
one (1) [31706301]
Temperature magnet for SKF Machine
Condition Detector Pro IS probe
[CMAC 3610]
Stinger probe 4 (10 cm) [CMSS 60139-04]
AA Alkaline batteries, two (2)
SKF Machine Condition Detector Pro IS
setup key [CMAC 3620]
SKF Machine Condition Detector Pro IS
padded carrying Case [31736700]
SKF Machine Condition Detector Pro IS
user manual [CMVL 3600M-SL]
SKF Machine Condition Detector Pro IS
quick start card [CMVL 3600-QS]
Optional accessories
Cable, SKF MARLIN I-Pro to SKF Machine
Condition Detector Pro IS [CMAC 6107]
SKF Machine Condition Detector Pro ISsetup key [CMAC 3620]
Temperature magnet for SKF Machine
Condition Detector Pro IS probe
[CMAC 3610]
Probe tip replacement kit for temperature
magnet for SKF Machine Condition
Detector Pro IS [CMAC 3630]
Magnetic probe tip for SKF Machine
Condition Detector Pro IS [CMAC 3611]
Stinger probe 10 cm (4)
[CMSS 60139-04]
1/4-28 MQC (MARLIN QuickConnect) for stinger interface [CMSS 2610-1]
SKF Machine Condition Detector Pro IS
quick start card [CMVL 3600-QS]
SKF Machine Condition Detector Pro IS
user manual [CMVL 3600M-SL]
SKF MARLIN data manager
The SKF Machine Condition Detector Pro
IS can be used in non-hazardous
conditions with the following SKF
MARLIN data managers as well as all
international language translation kits:
SKF MARLIN I-Pro CS, Bar Code Scanner
[CMDM 6210]SKF MARLIN I-Pro NI2, Bar Code Imager,
NI (Non-incendive) Class I Division 2
[CMDM 6220]
SKF MARLIN I-Pro NIA, Bar Code Imager,
NI (Non-incendive) ATEX Zone 2
[CMDM 6230]
SKF MARLIN S-Pro IS data manager,
ATEX Zone 1 [CMDM 5360]
SKF MARLIN QuickConnect and mounting
accessories
SKF MARLIN QuickConnect mechanical
M8 x 1.25 mounting thread three (3)studs per package [CMSS 2600-3]
SKF MARLIN QuickConnect mechanical
1/4-28 mounting thread three (3)
studs per package [CMSS 2610-3]
SKF MARLIN QuickConnect computerized
(patent pending) M8 x 1.25 mounting
thread three (3) studs per package
[CMSS 2601-3]SKF MARLIN QuickConnect computerized
(patent pending) 1/4 x 28 mounting
thread three (3) studs per package
[CMSS 2611-3]Tool kit for spot face 1/4-28
[CMAC 9600-01]
Tool kit for spot face M8 x 1.25
[CMAC 9600-02]
Drill bit for 1/4-28 kit [CMAC 9600-03]
Tap for 1/4-28 kit [CMAC 9600-04]
Pilot for 1/4-28 kit [CMAC 9600-05]
Drill bit for M8 x 1.25 kit
[CMAC 9600-06]
Tap for M8 x 1.25 kit [CMAC 9600-07]
Pilot for M8 x 1.25 kit [CMAC 9600-08]
End mill or counter bore for either kit
[CMAC 9600-09]
15
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
16/40
Now available in multiple languages (ML):
English, Chinese, German and Spanish.
With the SKF MicroVibe P, vibration
assessment is as close and convenient as
your PDA! This economical vibration meter
expansion module fits in a PocketPCs
compact flash card slot (CF Type II) and
features the user-friendly WindowsMobile
Operating System. Identify problems and
assess machine condition quickly and easily
with this versatile and easy-to-use pockettool.
Power without complexity
A handy quick-check solution, based on
the universal PDA platform, SKF MicroVibe
P is simple to use. Built-in automatic
functions virtually eliminate setup, while the
analytical displays and automatic judgment
of machine vibration readings help users
identify machine problems on the spot!
Features
Exceptional valueLow cost, compact, lightweight, works
with many Pocket PC PDAs by Hewlett-
Packard, Dell, Toshiba, etc.
Quickly identify problems
Expert judgment criteria based on ISO
vibration severity standard and SKF
bearing evaluation
The SKF MicroVibe P system.
SKF MicroVibe PCMVL 3850-ML
Power without complexity, an advanced instrument forsimplified vibration assessment that fits in your pocket.
FFT Spectrum analysis enables
user to pinpoint problems likeunbalance, misalignment, bearing,
rubs, etc.
Multi-point automation
Standard vibration measurements
Envelope acceleration,
acceleration, velocity,displacement, time waveform, and
FFT spectrum analysis
Store and recall measurements
For trending and analysis, store
up to 2,000 overall vibration
signals, 1,000 FFT spectrum, and
200 time waveforms
Data management software
Enables users to transfer
machinery vibration data to a computer
for trending and further analysis
SKF MicroVibe P kit includes:
SKF MicroVibe P module, data
management software, accelerometer
and cable, magnetic base, earphones,
user manual, and carrying case
(everything but the PDA).
An advanced instrument for simplified
vibration assessment
The SKF MicroVibe P collects and displays
overall vibration readings and automatically
provides expert judgment of the measured
velocity and overall enveloped acceleration
levels, enabling immediate, accurate and
reliable assessment of machine or bearing
condition.
Multi-point automation saves time and
improves reliability
Automatically collect the most useful
measurements for vibration analysis
acceleration, velocity, displacement, and
enveloped acceleration simultaneously.SKFs multi-point automationsaves time
and enhances the power, accuracy and
overall reliability of your decision making
giving you the information needed to make
the best possible judgment call.
16
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
17/40
FFT spectrum analysis capabilities
With pre-set measurements and user
selectable FFT resolution at 400, 800 or
1600-lines, selectable Fmax and a 90 db
dynamic range, the SKF MicroVibe P has
what it takes to help you easily pinpointimpending machine problems. Cursor
position readout with display zoom
optimizes your analysis power. In addition, it
automatically tabulates and displays the
highest vibration peaks from a spectrum,
making it easy to quickly identify signals
indicative of specific machine problems, like
misalignment, imbalance or bearing faults.
Automatic setup and onboard expertise
The MicroVibe P provides extensive
automatic setup and evaluation of vibration
results. Simply collect the data and the SKF
MicroVibe P does the rest comparing
readings to pre-programmed velocity andenveloped acceleration severity criteria for a
reliable and accurate evaluation of vibration
severity. This allows even novice users to
easily determine abnormal conditions and
take appropriate action.
Time-waveform displays
Measure and store time data, with the
capability to select acquisition type and time
measurement. Time displays in acceleration,
velocity, displacement or enveloped
acceleration. A unique automatic transientcapture function starts taking
measurements when the signal exceeds a
user-specified trigger level, enabling more
detailed analysis of the pre- and post-
trigger events surrounding a change in
machine condition.
Versatile measurement capability
The SKF MicroVibe P works with the two
most commonly used vibration sensors
accelerometers and dynamic velocity
transducers. Both enable you to take a
multi-parameter approach to your analysis
and to optimize vibration data gathering.
Audio analysis
Now you can actually listen to machine
problems using the SKF MicroVibe Psacoustic capability. Simply connect the
earphones and listen to the operation of
your machine. When abnormal noise is
detected, use the vibration analysis
capabilities of the SKF MicroVibe P to zero in
on the problem.
SKF MicroVibe P CMVL 3850-ML
17
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
18/40
_
1.5 m(5 ft)
40 mm(1.57 in)
20 mm(0.79 in)
Store and recall measurements for
trending and analysis
The SKF MicroVibe Ps data storage capacity
is also extraordinarily impressive. It can
store up to 2 000 overall vibration signals,
1 000 FFT spectrums or 200 records oftime waveform data for later recall. A search
function retrieves specific measurement
points and a repeat measurement lets you
recall and repeat any measurement for
more focused analysis or trending of a
potential problem. Finally, a recall data
storage list helps you keep track of and
reference all collected data.
Data management and software for your
desktop computer
The SKF MicroVibe P offers addedfunctionality, including a software program
to extract, save, edit and display collected
data. Its ideal for small route data collection.
For further analysis and trending, data
may be uploaded to your desktop computer
using the Data Management software. Once
uploaded, vibration data, overall trends and
spectra can be stored, trended, graphically
displayed and even exported to Excel.
Utilities add value
Several exciting utilities help make the SKF
MicroVibe P an universal tool for machine
vibration analysis, for any level of expertise.
Collect data in english or metric units or
reference a dictionary of vibrationterminology.
The SKF MicroVibe P truly brings you
vibration monitoring and analysis power
without complexity. Its tomorrows big
solution for vibration analysis in a small,
smart package and its available today! Get
more information at www.skf.com/cm.
Specifications
SKF MicroVibe P CMVL 3850-ML
Minimum PDA requirements(*): Conforms to the Pocket PC specifications
Operating system: Microsoft Windows
Mobile 3.0/5.0
Processor: ARM processor
Interface: Compact Flash TYPE II Slot 3.3
V only
Recommended specifications:
Processor: PXA255 400 MHz or higher
Memory (RAM): 64 MB or higher
Interface with Pocket PC: Compact Flash
TYPE II, slot 3.3 V only
Power supply: +3.3 V (supplied by Pocket
PC)Current:
Standby: 44 A
Under measurement: 48 mA
Pickup input (PU IN):
AC voltage signal: Maximum 2.5 V
Input terminal: 8-pin modular jack
(RJ-45), ICP type pre-amp built-in
accelerometer is not connected.
Raw waveform output (PU OUT):
AC voltage signal: Maximum 2.5 V
Output terminal: Mini-jack (2.5 mm F)
Sampling frequency: Maximum 76.8 kHz
(changes according to mode) 76.8 kHz/
38.4 kHz
Aliasing filter: 20 kHz/2 kHz (changes
according to mode and sampling
frequency)
A/D: 16-Bit
Temperature range: 0 to +45 C (+32 to
+113 F)
Humidity range:
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
19/40
Ordering Information
SKF MicroVibe P Kit CMVL 3850-ML
includes:
SKF MicroVibe P Module
Accelerometer, 1.5 meters (5 feet) integral
cable, with plug, and stinger one (1) each
[CMSS 3811]
Two-Bar Magnetic Base, high strength
35 lb. pull, one (1) each [CMAC 3825]
Earphones, one (1) each [CMAC 3830]
Data Management software CD-ROM,
one (1) each
SKF MicroVibe P documentation (English
and German)
User manual (PDF)
Data management software manual
(PDF)
Quick start guide (PDF)
CE declaration of confirmation
Carrying case
Note: Pocket PC (PDA) NOT INCLUDED.
Frequency specifications FFT specifications
Measurement Specifications
(For measurement with CMSS 3811 Accelerometer)
Overall and judgment specifications
Display specifications
Item Specifications
Frequencyrange
AVDE1E2E3E4
Acceleration: 10~15 kHz (*1)Velocity: 10~1000 HzDisplacement: 10~150 HzEnvelope Detection: 5~100 HzEnvelope Detection: 50~1 kHzEnvelope Detection: 500~10 kHzEnvelope Detection: 5 k~20 kHz
Samplingfrequency
A, E3, E4: 76.8 kHzE1, E2, V, D: 38.4 kHz
Aliasingfilter
A, E3, E4: 20 kHzE1, E2, V, D: 2 kHz
RangeA, E1, E2,
E3, E40~1 g: (100x range)0~5 g: (20x range)0~20 g: (5x range)0~100 g: (1x range)
V 0~10 mm/s: ( 100x range)0~50 mm/s: (20x range)0~200 mm/s: (5x range)0~1000 mm/s: (1x range)
D 0~50 m: (100x range)0~250 m: (20x range)0~1000 m: (5x range)0~5000 m: (1x range)
Item Specifications
Overall valuesimultaneousmeasurement
Simultaneous measurement ofoverall vibration level, multi-mode(A, V, D, E1~E4)
Range = AutoMeasuring Time = 0.1 s; 0.5 s;
1.0sMeasurement data = RMS value,
PEAK value, C. F. valueMeasured value display digits:
Significant figure 4 digitsExample: .9999/ 999.9/ 99.99/
9.999Status Display (Under
measurement, measurement end)
Judgment Abnormal judgment by vibrationseverity standard (ISO 10816
[JIS-B-0906] Standard)Abnormal bearing judgment by
enveloped acceleration E3 mode
Item Specification
Graphdisplay
FFT graph: Dominant frequency component
(highest 5 frequencies) Cursor indication value display Zoom scroll value displayWaveform graph: Cursor indication display Zoom scroll display
Item Specifications
FFT,waveformanalysis
Mode = A/ V/ D/ E1/ E2/ E3/ E4Range = Fixed/autoFFT measurement condition:
Analysis frequencies: Selection list A: 250/ 500/ 1k/ 2k/ 5k/ 10k/ 15k/30k Hz V: 250/ 500/ 1k Hz D: 250 Hz/(500 Hz for CMSS 3812Velocity Sensor only) E1: 50 Hz E2: 250/ 500 Hz E3: 250/ 500/ 1k/ 2k/ 5k Hz E4: 250/ 500/ 1k/ 2k/ 5k/ 10k HzLines of resolution: 1600/ 800/ 400Averaging: Stable/exponential/peakhold 1/ 2/ 4/ 8 timesWindow: Hanning
Measurement mode:Normal/ recorder/ post process
Normal: Recording time ofwaveform data is determined by FFTmeasurement condition (analysisfrequency, line number). Executesthe measurement for average cyclein FFT and records the waveform forframe time (final frame time). Recorder: Records the waveform ofspecified time by Rec. time. Averagecycle of FFT is one time. Rec. Time: 1/ 2/ 5/ 10 sec Post-process: Calculates from rawwaveform data (temporary saveddata). Average cycle of FFT is onetime.
SKF MicroVibe P CMVL 3850-ML
Additional Accessories
Accelerometer, 1.5 meters (5 feet) integral
cable (replacement), with plug, and
stinger, one (1) each [CMSS 3811]
Velocity Pickup Sensor, 1.5 meters (5 feet)
integral cable, with plug, one (1) each
[CMSS 3812]
Two-Bar Magnetic Base, high strength 40
lb pull, one (1) each [CMAC 3825]Earphones, one (1) each [CMAC 3830]
Certified Pocket PC PDAs with Windows
Mobile2003/2005
Certified Pocket PC PDAs with Windows
Mobile2003
Hewlett Packard
iPAQ hx2400
iPAQ hx2700
iPAQ hx2750
iPAQ hx4700
Toshiba
e830
ASUS MyPal A730
Dell AXIM X50 (NOT 51)
Compatible Pocket PC PDAs with Windows
Mobile2003
Hewlett Packard
iPAQ h2210
iPAQ h2215
Toshiba
e800
Certified Pocket PC PDAs with Windows
Mobile2005
Hewlett Packard
iPAQ hx2490
iPAQ hx2790
(*1) The upper bound frequency can be changedby Utili ty Menus A Filter.
19
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
20/40
Features
Solid-state reliability
Integral sensor
4-20 mA output
Dynamic signal output or temperature
4-20 mA output
Description
The CMSS 420 Series are solid state, loop-
powered vibration transmitters. They
provide a 4-20 mA output that is
proportional to overall vibration in terms ofvelocity. The series of CMSS 420
continuously monitor machinery health and
transmit directly into a PLC or DCS for
trending, alarm and machine shutdown. In
addition, the CMSS 420VT provides access
to the dynamic transducer output. The
buffered output is available for temporary
connection of portable analyzers for
detailed machine fault analysis.
Simple installation
Simply mount the CMSS 420VT into a
1/4-28 or M8 tapped hole in the bearinghousing or machine case (NPT Mounting
Adapters are available, part number CMSS
203), connect two wires into a 4-20 mA
loop, and you are ready to interface with a
PLC or DCS. Electrical conduit may be
connected directly to the top 3/4 NPT
fitting, (NPT Mounting Adapters are
available, part number CMSS 203).
Specifications
Dynamic
Output: 4-20 mA proportional to full
scale Velocity
Accuracy: 5 % of full-scale
Frequency response: 2-2 000 Hz
Frequency response accuracy:
3 db: 2 Hz to 2 kHz
10 %: 10 Hz to 1 kHz
5 %: 15 Hz to 750 Hz
Buffered output: Acceleration, 100 mV/g
Electrical
Power (Two wire loop power):
+22 to +36 Vdc
Maximum load (see note maximum
load resistance calculations for specific
requirements): Up to 600 Ohms resistive
Grounding: Case isolated
Environmental
Operating temperature: 20 to +80 C
(-4 to +176 F)
Sealed: Epoxy encapsulated
Enclosure: SS, NEMA 4, 4X, 12
Mounting: Stud mounted
Weight (without display): 227 g (8 oz.)
Regulatory approval
CE Mark: SKF Loop-powered Vibration
Transmitter CMSS 420VT and displays
CMSS 420LCD and CMSS 420LED
SKF Loop-powered VibrationTransmitters seriesCMSS 420VT
20
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
21/40
CMSS 420EL 90 Degree 3/4 by 3/4
NPT Elbow
Useful for connecting CMSS 420VT to
hard or flexible conduit. When used
with the CMSS 420WF, provides asimple weatherproof exit for the
instrument wire.
CMSS 203 Pipe Thread Accelerometer
Mounting Adapter
They are provided in several NPT sizes
to accommodate the most common
plugs found on most machinery. The
adapters have a 1/4-28 threaded
hole to mate with the CMSS 420VT
and most common accelerometers
and vibration transmitters.
Part numberPipe thread mountingadapter
CMSS 203-011/2 (NPT) National pipetapered thread
CMSS 203-023/4 (NPT) National pipetapered thread
CMSS 203-033/8 (NPT) National pipetapered thread
CMSS 203-041/4 (NPT) National pipetapered thread
Accessories
CMSS 420LCD/CMSS 420LED Display
Retrofit (requires transmitter).
LCD displays actual vibration levels in
velocity on a Liquid Crystal display.
LED displays actual vibration levels invelocity on a Light Emitting Diode
display. The displays are shipped loose,
and it is a simple installation. Includes
a BNC connector that provides access
to the raw acceleration signal for the
CMSS 420VT.
CMSS 420BNC BNC Adapter Retrofit
90 Degree 3/4 NPT conduit elbow
with a BNC connector to access the raw
acceleration signal. This is useful for
connecting the CMSS 420VT to the
portable data collectors.
CMSS 420WF 3/4 NPT Weatherproof
Cable Fitting
When used with the CMSS 420EL,
provides a simple weatherproof exit for
the instrument wire.
Ordering information
CMSS 420VT-1, 25.4 mm/sec. (0-1 in/
sec.) RMS, includes 1/4-28 and M8
Mounting Studs
CMSS 420VT-2, 50.8 mm/sec. (0-2 in/
sec.) RMS, includes 1/4-28 and M8Mounting Studs
Optional display
Light Emitting Diode
Display (LED)
Liquid Crystal Display
(LCD)
CMSS 420LED-010-1 in/sec.
CMSS 420LCD-010-1 in/sec.
CMSS 420LED-020-2 in/sec.
CMSS 420LCD-020-2 in/sec.
CMSS 420LED-5125.4 mm/sec.
CMSS 420LCD-5125.4 mm/sec.
CMSS 420LED-5250.8 mm/sec.
CMSS 420LCD-5250.8 mm/sec.
NOTE: Maximum load resistance calculations: RLoad = (Vs - 13.5 - Vd) / 0.032
Where: RLoad = Load Resistance Vs = DC Supply Voltage Vd = Display Voltage (5.0 Vdc for LED, 2.0 Vdcfor LCD, 0 Vdc if not using a display unit)
For Example:Using a LED Display and a Supply Voltage of 24 VdcSupply Voltage Vs = 24 V; Display Voltage Vd = 5.0Vdc for LED RLoad = (Vs - 13.5 V - Vd) / 0.032 = (24 V - 13.5 V - 5 Vdc) / 0.032 = 172 Ohm
SKF Loop-powered Vibration Transmitters series CMSS 420VT
21
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
22/40
Specifications
Specifications conform to ISA-
RP- 37.2 (1-64) and are typical
values referenced at +24 C
(+75 F), 24 Vdc supply, 4 mA
constant current and 100 Hz.
Dynamic
Sensitivity: 100 mV/g
Sensitivity precision: 5 % at
+25 C (+77 F)
Acceleration range: 80 g peak Amplitude linearity: 1 %, up
to full scale
Frequency range:
5 %; 3.0 to 5 000 Hz
10 %; 1.0 to 9 000 Hz
3 dB; 0.5 to 14 000 Hz
Resonance frequency:
Mounted, nominal 30 kHz
Transverse sensitivity: 5 % of
axial
Electrical
Power requirements:Voltage source: +24 Vdc
nominal, +18 to +30 Vdc
Constant current diode:
2 to 10 mA dc,
recommended 4 mA
Electrical noise: 2.0 Hz;
20 g/Hz
Output impedance: < 100
Bias output voltage: 12 Vdc
Grounding: Case isolated,
internal shielding
Environmental
Temperature range: 50 to
+120 C (58 to +248 F),
operating temperature
Vibration limits: 500 g peak
Shock limit: 5 000 g peak
Electromagnetic sensitivity,
equivalent g, maximum:
70 g/gauss
Sealing: Hermetic
Using detailed knowledge
acquired from many years of
supplying high quality sensors to
a broad spectrum of industry
users, SKF offers rugged
accelerometers designed for the
pulp and paper, petrochemical,
steel, mining and construction,
metal working, and machine
tool industries.
Features
For use with the SKF Junction
Boxes, On-line Systems,
Protection Systems and the
Portable Data Collection
Instruments
Rugged, economical, and all
around general purpose
sensor
Sensitivity, 100 mV/g to
optimize use in multiple
applications
Exceptional bias voltage (BV)
stability at elevatedtemperatures
Designed for exceptional low
noise level for low elevated
temperatures
Meets stringent CE, EMC
requirements
Smaller profile industrial
accelerometers
Two (2) mounting studs
(1/4-28 and M8 x 1.25)
provided
Corrosion resistant and hermetically sealed for
humidity areas
Reverse polarity wiring
protection
Base strain sensitivity:
200 g/microstrain
CE: According to the generic
immunity standard for
Industrial Environment
EN50082-2.
Acceptance Criteria: The
generated false equivalent g
level under the above test
conditions should be less than
2 milli g peak to peak.
Physical
Dimensions: See drawing
Weight: 90 grams
Case material: 316L stainless
steel
Mounting: Internal 1/4-28
thread. Mounting studs
provided. One (1) 1/4-28 to
1/4-28 english thread and
one (1) M8 x 1.25 metric
thread.
Mounting torque: 2,9 N-m(24 in-lbs)
Connector:
Pin A: Signal/Power
Pin B: Common
Mating connector:
CMSS 3106F-10SL-4S or
equivalent
Recommended cable: Two
conductor shielded, teflon
jacket, 100 pF/m (30 pF/ft)
Ordering information
CMSS 2100 General purpose
industrial accelerometer with
top exit MIL-C-5015 two (2)
pin connector.
1/4-28 and M8 mounting
studs provided. Calibration
sensitivity and nominal
sensitivity is provided for
each accelerometer
package.
Diagrams
MODEL CMSS2100
S/N S00000
A B
53.0 mm(2.10)
1/4-28MountingHole19.0 mm
(0.75)
Diameter
22.3 mm(0.87)
20.3 mm(0.80)
7/8 Hex
2-Pin ConnectorMIL-C-5015
-20 0 +25 +50 +80 +120 (-4) (+32) (+77) (+122) (+176) (+248)
Temperature C (F)
Typical Temperature Response20
10
0
-10
-20
De
viation,
%
Sensitivity
0.5 10 100 1 k 20 K
Frequency, Hz
Typical Frequency Response3
2
1
0
-1
-2
-3
eviation,
d
CMSS 2100General purpose industrial accelerometer
Incorporating the latest in technology to meet the demandingCE, EMC, and low noise level requirements.
22
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
23/40
Specifications
Specifications conform to
ISA-RP-37.2 (1-64) and are
typical values referenced at
+24 C (+75 F), 24 Vdc
supply, 4 mA constant current
and 100 Hz.
Dynamic
Sensitivity: 100 mV/g Sensitivity precision: 10 % at
+25 C (+77 F)
Acceleration range: 80 g peak
Amplitude linearity: 1 %
Frequency range:
10 %; 1.0 to 5 000 Hz
3 dB; 0.7 to 10 000 Hz
Resonance frequency:
Mounted, minimum 22 kHz
Transverse sensitivity: 5 % of
axial
ElectricalPower requirements:
Voltage source: +18 to
+30 Vdc
Constant current diode:
2 to 10 mA dc,
recommended 4 mA
Electrical noise: 2.0 Hz;
20 g/Hz
Output impedance:
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
24/40
Description
CMSS 9100 is a single shielded, single
twisted pair cable with the conductors
individually insulated with Dupont FEP
Teflon, a braided shield with drain wire and
an outer insulated jacket also made of clear
Dupont FEP Teflon. The cable is wrapped
with a color tape under the outer insulated
jacket and also has superimposed on the
color tape a white marker tape with cable
designation and SKF logo.
CMSS 9200 is a double shielded, singletwisted pair cable with the conductors
individually insulated with Dupont FEP
Teflon, an inner shield of aluminum
polyester foil with drain wire, an inner
insulated jacket of Dupont FEP Teflon, a
braided outer shield and the outer insulated
jacket of clear Dupont FEP Teflon. The cable
is wrapped with a color tape under the outer
insulated jacket and also has superimposed
on the color tape a white marker tape with
cable designation and SKF logo.
Recommended usesThe single shield cable is recommended for
use with sensors in normal industrial
applications where historically these type
cables have been previously used and
installed.
The double shield cable is highly
recommended for use with sensors in
industrial installations where there is a high
noise field with one such example being
machine tools and another being power
generating facilities.
Specifications
(applicable to both models)
Conductors: Tin plated copper, 19 x 32
strands, size 20 AWG (American Wire
Gauge).
Color code: Black and White pair, Cable
color is yellow with white SKF label.
Outer jacket diameter: 0.190 in.
(0.005 in.), includes glass fillers for
roundness.
Wire materials: All conductors, drain wires
and braided shields are of tin platedcopper.
Capacitance: Approximately 89 pF/m
(27 pF/ ft).
Voltage rating: 600 V RMS.
Working temperature range:
80 to +200 C (112 to +392 F).
Heat and flame resistance: Meets
requirements of UL 910 Stiner Tunnel
test.
Single/Double Shield Twisted Pair CablesCMSS 9100/CMSS 9200
SKFs CMSS 9100 and CMSS 9200 premium sensor cables provide superior performance indemanding environments.
Ordering information
CMSS 9100-500 500 foot spool (150
meters) single shield with continuous
cable length.
CMSS 9100-1000 1,000 foot spool (300
meters) single shield with continuous
cable length.
CMSS 9200-500 500 foot spool (150
meters) double shield with continuous
cable length.
24
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
25/40
Features
Q-type connector
IP 68 (submersible, one meter of water)High temperature +200 C (+392 F)
Standard recommendation for harsh
environments
Features
SL-type connector
IP 66 (withstands direct water jet)
Elevated temperature +150 C (+302 F)
Premium connector
SKF Cable Assembly IP 68CMSS R6Q(I)*-9100-XX
Ordering information
Available in two versions:
I = Isolated type, for grounding on
instrument side, or leave blank for
grounding on machine side.
-XX = 16, 32 or 64 for equivalent
length in feet
SKF Cable Assembly IP 66CMSS R6SL(I)*-9100-XXOrdering information
Available in two versions:
I = Isolated type, for grounding on
instrument side, or leave blank for
grounding on machine side.
-XX = 16, 32 or 64 for equivalent
length in feet
25
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
26/40
CMSS 260 series NEMA 4 and NEMA 4X Enclosures
CMSS 265 series Termination Junction Boxes
CMSS 300 series BNC Junction Boxes
CMSS 310 series Switchable BNC Junction Boxes
Industry standards
(For all junction boxes and enclosures) and according to version (material).
Rating Painted Steel Fiberglass Stainless Steel
UL 50 Type 4, 12 and 13 N/AType 3R, 4, 4X
and 12
UL 508A, UL 508 Type 4, 12 and 13Type 3R, 4, 4X
and 12Type 3R, 4, 4X
and 12
NEMA/EEMAC Type 4, 12 and 13Type 3R, 4, 4X
and 12Type 3R, 4, 4X
and 12
JIC EGP-1-1967 EGP-1-1967 EGP-1-1967
CSA Type 4 and 12 Type 4, 4X and 12 Type 4, 4X and 12
IEC 60529 IP66 IP66 IP66
CMSS 310 series Switchable BNC Junction Boxes
CMSS 260 series NEMA 4 and NEMA 4X enclosures
CMSS 265 series Termination Junction Boxes
CMSS 300 series BNC Junction Boxes
Junction Boxes and EnclosuresCMSS 260, CMSS 265, CMSS 300 and CMSS 310
26
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
27/40
CMSS 260PS NEMA 4 PaintedSteel Enclosures
These enclosures are designed for use inareas that may be regularly hosed downor are very wet, and they are suitablefor indoor or outdoor installations.Wherever protection from dust, dirt, oil,
or hose-directed water is essential.
ANSI 61 powder coated on the interiorand exterior surfaces, constructed from14 gauge mild steel.
Ordering information
CMSS 260PS -XX
NEMA 4 PaintedSteel Enclosures
(dimensions -height x width x depth)
-0115.2 cm x 15.2 cm x10.2 cm(6.0 x 6.0 x 4.0)
-0220.3 cm x 15.2 cm x8.9 cm(8.0 x 6.0 x 3.5)
-0325.4 cm x 20.3 cm x15.2 cm(10.0 x 8.0 x 6.0)
CMSS 260FG NEMA 4XFiberglass Enclosures
NEMA 4X Fiberglass Enclosures aredesigned for use in areas that may beregularly hosed down or are very wet,and they are suitable for indoor oroutdoor installations.
The enclosure is used in highlycorrosive environments typically foundin oil refineries, chemical processingplants, waste-water treatment, marineinstallations, pulp and paper processing,and electroplating plants.
Ordering information
CMSS 260FG -XX
NEMA 4X FiberglassEnclosures(dimensions -
height x width x depth)
-01 15.2 cm x 15.2 cm x10.2 cm(6.0 x 6.0 x 4.0)
-0220.3 cm x 15.2 cm x8.9 cm(8.0 x 6.0 x 3.5)
-0325.4 cm x 20.3 cm x15.2 cm(10.0 x 8.0 x 6.0)
The enclosures covers have a continuous hinge on the long side of the unit for convenience, and are secured to the enclosure with clamps.The enclosures are available in NEMA 4 or NEMA 4X to cover most applications. All enclosures are provided with an oil resistant gasket and
clamps for easy screwdriver access.
CMSS 260SS NEMA 4XStainless Steel Enclosures
Constructed from 14 gauge 304 stainlesssteel rather than a mild steel. They aredesigned for the same use as the NEMA4 enclosures with the ability to resistcorrosive environments.
Ordering information
CMSS 260SS -XX
NEMA 4X StainlessSteel Enclosures
(dimensions -height x width x depth)
-0115.2 cm x 15.2 cm x10.2 cm(6.0 x 6.0 x 4.0)
-0220.3 cm x 15.2 cm x8.9 cm(8.0 x 6.0 x 3.5)
-0325.4 cm x 20.3 cm x15.2 cm
(10.0 x 8.0 x 6.0)
NEMA 4 and NEMA 4X EnclosuresCMSS 260 series
NEMA 4 and NEMA 4X enclosures are provided by SKF for housing of any instrument.
27
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
28/40
The CMSS 265 series Termination Junction Boxes are multiple channel connectingcenters for terminating the outputs of accelerometers or other transducer field wiring.
Crew clamp, DIN-rail mounted terminals (3 inputs per channel, usually signal, commonand shield) are provided for the intermediate termination of accelerometers, proximityprobes, speed sensors, RTDs, and other transducers.
The CMSS 265 seriesJunction Boxes areavailable in three (3)versions:
NEMA 4X Fiberglass(FG)
NEMA 4 PowderCoated Steel (PS)
NEMA 4X StainlessSteel (SS)
CMSS 265FG NEMA 4XFiberglass Junction Boxes
The CMSS 265FG NEMA 4X enclosuresare made of molded fiberglass polyesterand is easily punched or drilled. It hasoutstanding chemical and temperatureresistance and physical properties. A
seamless foam in-place gasket assuresa watertight and dust tight seal. Screwcovers are secured with captivated monelcover screws.
Ordering information
CMSS 265FG -XXNEMA 4X Fiberglass
Junction Box
-022 channels,6 terminals
-044 channels,12 terminals
-08 8 channels,24 terminals
-1212 channels,36 terminals
-1616 channels,48 terminals
CMSS 265SS NEMA 4XStainless Steel Junction Boxes
The CMSS 265SS NEMA 4X enclosureis constructed from 14 gauge 304Stainless Steel. This enclosure will betterresist corrosive environments than theCMSS 265PS steel boxes. CMSS 265SS
junction boxes feature continuouslywelded seems, ground smooth with noholes or knockouts. An oil-resistant,in-place gasket assures a watertight anddust tight seal. Stainless Steel screwsand clamps are provided.
Ordering information
CMSS 265SS -XXNEMA 4X 304Stainless SteelJunction Box
-022 channels,6 terminals
-044 channels,12 terminals
-088 channels,24 terminals
-1212 channels,36 terminals
-1616 channels,48 terminals
Dimensional information
Description Dimensions(height x width x depth)
2 channels,6 terminals
15.2 cm x 15.2 cm x 10.2 cm(6.0 x 6.0 x 4.0)
4 channels,12 terminals
15.2 cm x 15.2 cm x 10.2 cm(6.0 x 6.0 x 4.0)
8 channels,24 terminals
20.3 cm x 15.2 cm x 10.2 cm(8.0 x 6.0 x 4.0)
12 channels,36 terminals
25.4 cm x 20.3 cm x 15.2 cm(10.0 x 8.0 x 6.0)
16 channels,48 terminals
35.6 cm x 30.5 cm x 20.3 cm(14.0 x 12.0 x 8.0)
CMSS 265PS NEMA 4 PowderCoated Steel Junction Boxes
The CMSS 265PS NEMA 4 enclosure isconstructed of 14 gauge mild steel andis ANSI 61 gray polyester powder coatedon the all surfaces. A seamless foamin-place gasket assures a watertight and
dust tight seal.
Ordering information
CMSS 265PS -XXNEMA 4 Powder
Coated SteelJunction Box
-022 channels,6 terminals
-044 channels,12 terminals
-088 channels,24 terminals
-12
12 channels,
36 terminals
-1616 channels,48 terminals
Termination Junction BoxesCMSS 265 series
28
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
29/40
Features
Quick and convenient access to remotely installedaccelerometers with Portable Data Collector/Analyzer
Withstands harsh factory and outdoorenvironments
The CMSS 300 series BNC Junction Boxes aremultiple channel connecting centers for terminatingthe outputs of accelerometers or other transducerfield wiring. They are normally located in closeproximity to the machine to reduce wiring cost andprovide convenient access to the vibration signal bya portable data collector/analyzer.
The CMSS 300 series Junction Boxes are availablein three (3) versions:
NEMA 4X Fiberglass (FG)
NEMA 4 Powder Coated Steel (PS)
NEMA 4X Stainless Steel (SS)
Both internal and external switch/BNC models areavailable. Internal models are provided with quickaccess latches and external models with screwcovers and protective caps for the BNC fitting. Inharsh environments internal models should bespecified. Black and white bezel tagging is providedfor channel and switch identification.
CMSS 300FG NEMA 4X Fiberglass Junction Boxes
The CMSS 300FG NEMA 4X Fiberglass enclosure is made of moldedfiberglass polyester and is easily punched or drilled. It has outstandingchemical and temperature resistance and physical properties.
A seamless foam in-place gasket assures a watertight and dust tight seal.
Screw covers are secured with captivated Monel cover screws.
Ordering information
CMSS 300FG -XX -XXNEMA 4X FiberglassBNC Junction Box
Dimensions(height x width x depth)
-01 1 Channel16.5 cm x 16.5 cm x 10.8 cm(6.50 x 6.50 x 4.25)
-02 2 Channels16.5 cm x 16.5 cm x 10.8 cm(6.50 x 6.50 x 4.25)
-04 4 Channels21.6 cm x 16.5 cm x 10.8 cm(8.50 x 6.50 x 4.25)
-06 6 Channels21.6 cm x 16.5 cm x 10.8 cm(8.50 x 6.50 x 4.25)
-01 Internal BNC
-02 External BNC
BNC Junction BoxesCMSS 300 series
29
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
30/40
CMSS 300PS NEMA 4 Powder Coated Steel Junction Boxes
The CMSS 300PS Powder Coated Steel NEMA 4 enclosure is constructed of 14 gauge mild steel and is ANSI 61 gray polyesterpowder coated on the all surfaces.
Ordering information
CMSS 300PS -XX -XXNEMA 4 Powder CoatedSteel BNC Junction Box
Dimensions(height x width x depth)
-01 1 Channel 19.1 cm x 17.8 cm x 10.2 cm (7.50 x 7.00 x 4.00)
-02 2 Channels 19.1 cm x 17.8 cm x 10.2 cm (7.50 x 7.00 x 4.00)
-04 4 Channels 24.1 cm x 17.8 cm x 8.9 cm (9.50 x 7.00 x 3.50)
-06 6 Channels 24.1 cm x 17.8 cm x 8.9 cm (9.50 x 7.00 x 3.50)
-01 Internal BNC
-02 External BNC
CMSS 300SS NEMA 4X Stainless Steel Junction BoxesThe CMSS 300SS NEMA 4X Stainless Steel enclosure is constructed from 14 gauge 304 Stainless Steel.
Ordering information
CMSS 300SS -XX -XXNEMA 4X Stainless Steel
BNC Junction BoxDimensions
(height x width x depth)
-01 1 Channel 19.1 cm x 12.7 cm x 10.2 cm (7.50 x 5.00 x 4.00)
-02 2 Channels 19.1 cm x 12.7 cm x 10.2 cm (7.50 x 5.00 x 4.00)
-04 4 Channels 24.1 cm x 17.8 cm x 10.2 cm (9.50 x 7.00 x 4.00)
-06 6 Channels 24.1 cm x 17.8 cm x 10.2 cm (9.50 x 7.00 x 4.00)
-01 Internal BNC
-02 External BNC
CMSS 300 series BNC Junction Boxes
30
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
31/40
Features
The CMSS 310 series Switchable BNC JunctionBoxes are designed for terminating and switchingthe outputs of up to 48 accelerometers. Theyare installed in a location as close to the machineas practical to reduce wiring cost and yet provideconvenient safe access to the vibration signalby an operator with a portable data collector oranalyzer.
The CMSS 310 series Switchable BNC JunctionBoxes are available in three (3) versions:
NEMA 4X Fiberglass (FG)
NEMA 4 Powder Coated Steel (PS)
NEMA 4X Stainless Steel (SS)
Both internal and external switch/BNC models areavailable. Internal models are provided with quickaccess latches and external models with screwcovers and protective caps for the BNC fitting.In harsh environments internal models shouldbe specified. Black and white bezel tagging isprovided for channel and switch identification.
CMSS 310FG NEMA 4X Fiberglass Junction Boxes
The CMSS 310FG NEMA 4X Fiberglass enclosure is made of molded fiberglasspolyester and is easily punched or drilled. It has outstanding chemical andtemperature resistance and physical properties.
A seamless foam in-place gasket assures a watertight and dust tight seal.Screw covers are secured with captivated Monel cover screws.
Ordering information
CMSS 310FG -XX -XXNEMA 4X Fiberglass
Switchable BNCJunction Box
Dimensions(height x width x depth)
-06 6 Channels24.1 cm x 17.8 cm x 8.9 cm(9.50 x 7.00 x 3.50)
-12 12 Channels24.1 cm x 17.8 cm x 8.9 cm(9.50 x 7.00 x 3.50)
-24 24 Channels39.4 cm x 33.0 cm x 15.2 cm(15.50 x 13.00 x 6.00)
-32 32 Channels44.5 cm x 38.1 cm x 15.2 cm(17.50 x 15.00 x 6.00)
-48 48 Channels44.5 cm x 38.1 cm x 15.2 cm(17.50 x 15.00 x 6.00)
-01 Internal BNC
-02 External BNC
Switchable BNC Junction BoxesCMSS 310 series
31
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
32/40
CMSS 310PS NEMA 4 Powder Coated Steel Junction Boxes
The CMSS 310PS NEMA 4 Powder Coated Steel enclosure is constructed of 14 gauge mild steel and is ANSI 61 gray polyesterpowder coated on the all surfaces.
Ordering information
CMSS 310PS -XX -XXNEMA 4 Powder CoatedSteel BNC Junction Box
Dimensions(height x width x depth)
-06 6 Channels 24.1 cm x 17.8 cm x 8.9 cm (9.50 x 7.00 x 3.50)
-12 12 Channels 24.1 cm x 17.8 cm x 8.9 cm (9.50 x 7.00 x 3.50)
-24 24 Channels 39.4 cm x 33.0 cm x 15.2 cm (15.50 x 13.00 x 6.00)
-32 32 Channels 44.5 cm x 38.1 cm x 15.2 cm (17.50 x 15.00 x 6.00)
-48 48 Channels 44.5 cm x 38.1 cm x 15.2 cm (17.50 x 15.00 x 6.00)
-01 Internal BNC
-02 External BNC
CMSS 310SS NEMA 4X Stainless Steel Junction Boxes
The CMSS 310SS NEMA 4X Stainless Steel enclosure is constructed from 14 gauge 304 Stainless Steel.
Ordering information
CMSS 310SS -XX -XXStainless Steel NEMA 4X
BNC Junction BoxDimensions
(height x width x depth)
-06 6 Channels 24.1 cm x 17.8 cm x 10.2 cm (9.50 x 7.00 x 4.00)
-12 12 Channels 24.1 cm x 17.8 cm x 10.2 cm (9.50 x 7.00 x 4.00)
-24 24 Channels 39.4 cm x 33.0 cm x 15.2 cm (15.50 x 13.00 x 6.00)
-32 32 Channels 44.5 cm x 38.1 cm x 15.2 cm (17.50 x 15.00 x 6.00)
-48 48 Channels 44.5 cm x 38.1 cm x 15.2 cm (17.50 x 15.00 x 6.00)
-01 Internal BNC
-02 External BNC
CMSS 261 Liquid Tight Strain Relief Connectors
The CMSS 261 Liquid Tight Strain Relief Connectors are usedfor either extension cable or multi-conductor wire entriesinto the CMSS 310 BNC Junction boxes. Connectors areconstructed of Polyamide and provide both environmentalsealing and strain relief. The connectors are temperature ratedto -60 C to +100 C (-40 F to +212 F) and have a pressurerating of up to 150 PSIG. Check the cable data sheet for thediameter of your extension cable.
Ordering information
CMSS 261 -XXMinimum OuterCable Diameter
Maximum OuterCable Diameter
-01 2 mm (0.08) 5 mm (0.20)
-02 4 mm (0.16) 8 mm (0.31)
-03 5 mm (0.20) 9 mm (0.35)
-04 7 mm (0.28) 12 mm (0.47)
-05 9 mm (0.35) 18 mm (0.70)
-06 13 mm (0.51) 20 mm (0.78)
CMSS 310 series Switchable BNC Junction Boxes
32
-
7/21/2019 CM2355 SKF Condition Monitoring Essentials
33/40
parameter for judging rotational andstructural problems like imbalance,resonance, misalignment, looseness,and stress applied to components.
Many machinery problems may causeexcessive overall vibration. Mechanicallooseness, imbalance, soft foundation,misalignment, rotor bow, resonance,eccentricity, bad belts, or lost rotorvanes can all be measured with overallISO (International Organization for
Standardization) vibration measurements.
Measuring the overall vibration of amachine or component, or the structure ofa machine, and comparing the measuredvalue to the machines normal value (or toISO 10816 standards) indicates machineryhealth and condition changes.
NOTE: Overall vibration is not an indicator ofbearing or gear mesh problems thattypically occur in higher frequencyranges.
Enveloped acceleration
Bearing/gear mesh frequency vibration(10 kHz to 30 kHz)
Enveloped acceleration measurementsmeasure the high frequency repetitivevibration signals typically caused bybearing and gear mesh problems.
Envelope detection is very useful in rollingelement bearing and gear mesh analysiswhere a low amplitude, repetitive vibrationsignal may be hidden by the machinesrotational and structural vibration noise.
For example, suppose a rolling elementbearing has a defect on its outer raceway.Each rolling element strikes the defectas it passes the defect, causing a small,repetitive vibration signal. This vibrationsignal is of such low amplitude that, undernormal ISO vibration monitoring, it islost in the machines other rotational andstructural noise.
Envelope detection filters out lowfrequency rotational signals, then enhancesthe high frequency defect signals to focus
Overview
A multi-parameter approach to conditionmonitoring provides two different methodsfor monitoring machinery condition.This allows for early detection of specificmachinery problems and provides moreways to measure changes in machinerycondition.
The SKF Vibration Penplusis a multi-parameter vibration monitoring tool
capable of measuring vibration (causedby rotational and structural problemslike imbalance, misalignment, looseness,etc.), and capable of measuring vibrationin higher frequencies (caused by rollingelement bearing or gear mesh problems).
Multi-parameter monitoring is themost thorough and effective methodfor monitoring bearing and machinerycondition. The Vibration Penplustoolsmulti-parameter approach providesaccurate and reliable data upon which tobase maintenance decisions and promotesearly detection, confirmation, and accurate
trending of bearing and machineryproblems.
Functional description
When performing measurements, theVibration Penplustools sensor input signalis processed to produce two differentmeasurements for each machineryPOINT, Overall Vibration and envelopedacceleration.
The Vibration Penplustools LCDsimultaneously displays both measurement
values. Depending on the type andlocation of the machinery componentbeing measured, either or both readingsmay be of interest.
Overall vibration
(ISO* 10816, Part 1-6) Low frequencyvibration (10 Hz to 1 kHz)
Overall velocity vibration occurring inthe 10 Hz to 1 kHz frequency band isconsidered the best operating
on repetitive events in the 10 kHz to30 kHz frequency range, and provides an
averaged peak value for early detection ofbearing and gear mesh problems.NOTE: Enveloped acceleration measurements
do not detect rotational or structuralvibration caused by imbalance,misalignment, looseness, etc.
Easy operation
Vibration Penplusreadings are easilyperformed, simply:
Turn the Vibration Pen pluson.Press the Vibration Pen plustoolssensor tip against your machinery
measurement POINT.Wait for the readings to stabilize, andrecord the measurement values.
Easy evaluation
The Vibration Penplustools front-panelLCD simultaneously shows overall velocityvibration readings in mm/s RMS (CMVP50) or in in/s equivalent Peak (CMVP 40),and acceleration enveloping readings in gE(E indicating enveloped acceleration).
The SKF Vibration Penplusseveritycard provides quick reference for