cm2355 skf condition monitoring essentials

Upload: anonymous-7w8eoajcg

Post on 07-Mar-2016

16 views

Category:

Documents


1 download

DESCRIPTION

skf cm

TRANSCRIPT

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    1/40

    SKF Junction Boxesand Enclosures

    SKF MicroTempThermometer

    CMSS 2020-SL

    SKF Vibration Penplus

    CMVP 40/CMVP 50

    SKF Inspector 400Ultrasonic Probe

    CMIN 400-K

    SKF InfraredThermometer

    CMSS 3000-SL

    SKF Machine ConditionDetector Pro ISCMVL 3600-IS

    SKF MicroVibe PCMVL 3850-ML

    SKF CMSS 2100 GeneralPurpose Industrial

    Accelerometer

    SKF CMSS 2200/CMSS 2200-M8

    General Purpose LowProfile IndustrialAccelerometer

    SKF Cable Assemblies

    SKF Loop-powerdVibration

    Transmitters seriesCMSS 420VT

    SKF Temperature ProbeCMSS 2000-SL

    SKF Machine ConditionAdvisor CMAS 100-SL

    SKF Basic ConditionMonitoring KitCMPK 200plus/CMPK 210plus

    SKF Bearing Analysis KitCMPK 60plus/CMPK 70plus

    SKF Reliability Systems standard product offering:

    SKF Reliability Systems

    condition monitoringessentials

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    2/40

    Description Page

    Introduction 3

    SKF Machine Condition Advisor CMAS 100-SL 4

    SKF Infrared Thermometer CMSS 3000-SL 8

    SKF Inspector 400 Ultrasonic Probe CMIN 400-K 10

    SKF Machine Condition Detector Pro IS CMVL 3600-IS Machine Reliability Inspection System Intrinsically Safety (IS) rated

    13

    SKF MicroVibe P CMVL 3850-ML 16

    SKF Loop-powered Vibration Transmitters series CMSS 420VT 20

    SKF CMSS 2100 General Purpose Industrial Accelerometer 22

    SKF CMSS 2200/CMSS 2208-M8 General Purpose Low Profile Industrial Accelerometer 23

    SKF Single/Double Shield Twisted Pair Cables CMSS 9100/CMSS 9200 24

    SKF Cable Assembly IP 68 CMSS R6Q(I)-9100-XX 25

    SKF Cable Assembly IP 66 CMSS R6SL(I)-9100-XX 25

    SKF Junction Boxes and Enclosures 26

    CMSS 260 NEMA 4 and NEMA 4X Enclosures 27

    CMSS 265 series Termination Junction Boxes 28

    CMSS 300 series BNC Junction Boxes 29

    CMSS 310 series Switchable BNC Junction Boxes 31

    SKF Vibration PenplusCMVP 40 english system (in/s; equivalent Peak)/CMVP 50 metric system (mm/s; RMS) 33

    SKF Temperature Probe CMSS 2000-SL 35

    SKF MicroTemp Non-contact Thermometer CMSS 2020-SL 37

    SKF Basic Condition Monitoring Kit CMPK 200plusmetric system/CMPK 210plusenglish system 38

    SKF Bearing Analysis Kit CMPK 60plusmetric system/CMPK 70plusenglish system 39

    Product Support Plans (PSP)Backcover

    Table of contents

    2

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    3/40

    Introduction

    Global presence localsolutions

    With over 100 years of experience, SKF stands

    alone as a total solution provider for maximizingmachine and plant productivity. With a

    reputation for quality, technological innovation

    and service that spans the globe, SKF brings

    what no other vendor can to the maintenance

    arena.

    Local SKF sales and service representatives

    and worldwide distributors provide access to

    the range of SKF bearings, maintenance

    products, lubricants and condition monitoring

    instrumentation and software, independent of

    your location.

    In any kind of rotating machinery, from hugerolling machines to the smallest of motors, the

    bearing knows if there is a potential problem.

    As the primary interface between moving parts,

    the bearing is literally the diagnostic heart of

    the machine.

    Misalignment, unbalance, looseness and

    friction, are all telegraphed through the

    bearing. Understanding the information

    coming from this diagnostic pulse and then

    applying the latest and best technology to the

    problem is the key to raising machine

    productivity and lowering operating costs.

    This SKF Reliability Systems conditionmonitoring essentials product catalogue

    features a convenient collection of monitoring

    tools that no industrial manufacturing plant

    should be without.

    3

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    4/40

    SKF Machine Condition AdvisorCMAS 100-SL

    Machine monitoring, made simple

    Introduction

    Now both novice users and experts can

    easily, quickly and accurately check the

    condition of rotating equipment throughout

    your facility. Equipping your maintenance

    and operations personnel with this rugged,

    ergonomic and easy-to-use instrument can

    provide early warning of potential machine

    problems before a costly failure occurs.

    Multiple measurements with a single

    device

    The SKF Machine Condition Advisor provides

    an overall Velocity vibration reading that

    measures vibration signals from the

    machine and automatically compares them

    to pre-programmed International

    Organization for Standardization (ISO)

    guidelines. An Alert or Danger alarm

    displays when measurements exceed those

    guidelines. Simultaneously an Enveloped

    Acceleration measurement is taken and

    compared to established bearing vibration

    guidelines to verify conformity or indicate

    potential bearing damage.The SKF Machine Condition Advisor also

    measures temperature using an infrared

    sensor to indicate uncharacteristic heat.

    Features

    Quick and easy to set up and use,

    measurements are shown on a bright

    display viewable in low light to direct

    sunlight. Free on-line training is also

    available at SKF @ptitude Exchange.

    Lightweight, compact and ergonomically

    designed, the SKF Machine Condition

    Advisor fits neatly at the belt line, in a

    pocket or a tool kit. Exceptionally durable,

    the unit is rated IP 54 for use in adverse

    industrial environments.Alert and Danger prompts provide

    increased diagnostic confidence.

    SKF Machine Condition Advisor simultaneouslymeasures vibration signals and temperature toindicate machine health or bearing damage.

    Measuring Velocity, Enveloped

    Acceleration and temperature

    simultaneously saves time.

    Efficient, economical and environmentally

    friendly, the rechargeable SKF Machine

    Condition Advisor operates 10 hours on a

    single charge.

    Flexible enough to work with standard

    100 mV/g ICP accelerometers, an optional

    external sensor can be used for hard-to-

    reach locations.Features English, French, German,

    Portuguese, Spanish and Swedish for

    user convenience.

    4

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    5/40

    Accuracy, flexibility and confidence

    When performing measurements, the SKF

    Machine Condition Advisors acceleration

    sensor input signal is processed to produce

    two different measurements for each POINT

    on the machinery overall velocity andenveloped acceleration. At the same time,

    the SKF Machine Condition Advisors non-

    contact infrared sensor measures the

    surface temperature of the measurement

    location and simultaneously displays all

    three measurement values.

    LCD display in measurement mode

    ISO machinegroup

    EnvelopedAcceleration

    class

    Batteryindicator(60% full)

    Measurementstatus

    Temperature

    EnvelopedAcceleration Velocity

    Alarm display:(A) Alert or(D) Danger

    Selectbutton

    Browsebutton

    Specifications

    Vibration pickup:

    Internal: Integrated piezoelectric

    acceleration

    External: Accepts ICP type 100 mV/g

    accelerometer

    Temperature sensor: Internal IR

    temperature sensor

    Measurements:

    Velocity:

    Range: 0.765 mm/s (RMS),

    0.043.60 in/s (equivalent Peak),

    meets ISO 10816

    Frequency: 101 000 Hz, meets

    ISO 2954

    Enveloped acceleration:

    Range: 0.250.0 gE

    Frequency: Band 3 (50010 000 Hz)

    Weight: 125 g (4.4 oz)

    Dimensions:

    Length: 200 mm (7.90 in)

    Width: 47 mm (1.85 in)

    Height: 25.4 mm (1.00 in)

    Battery capacity: 550 mA hours

    Battery life: 10 hours before charging

    again (1 000 measurements)With external sensor: Up to 55 % less

    battery life

    Supported external sensor: Any standard

    accelerometer with 100 mV/g sensitivity

    that needs ICP (Integrated circuit-

    piezoelectric)

    External sensor power: 24 V DC at 3.5 mA

    Charger specifications:

    Universal AC/DC wall plug-in

    Input: 90264 VAC, 4760 Hz

    Output: 5 V DC regulated

    3 to 4 hours for a full charge

    Temperature:

    Range: 20 to +200 C (4 to

    +392 F)

    IR temperature accuracy: 2 C

    (3.6 F)

    Distance: Short range, maximum

    10 cm (4 in) from target

    Operating temperature range:

    In use: 10 to +60 C (+14 to +140 F)

    While charging: 0 to +40 C (+32 to

    +104 F)

    Storage temperature:

    Less than one month: 20 to +45 C

    (4 to +113 F)

    More than one month but less than six

    months: 20 to +35 C (4 to +95 F)

    Humidity: 95 % relative humidity,

    non-condensing

    Enclosure: IP 54

    Approvals: CE

    Drop test: 2 m (6.6 ft)

    SKF Machine Condition Advisor CMAS 100-SL

    Depending on the SKF Machine Condition

    Advisors System setting, the front-panel

    LCD simultaneously displays:

    Units in Metric or EnglishVelocity in mm/s RMS or IPS derived Peak

    Temperature in Celsius or Fahrenheit

    Acceleration enveloping readings in gE

    Quick and easy first time and every time

    Press Select or Browse button to turn1

    the SKF Machine Condition Advisor On

    Press the sensor tip against the point to2

    be measured

    When the readings stabilize, press the3Select button to hold the reading

    Read and record the measurement values4

    5

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    6/40

    Understanding and using guidelines for

    vibration

    The SKF Machine Condition Advisor provides

    a means to evaluate machine health based

    on ISO 10816-3 and to evaluate the

    bearings according to general guidelinesdeveloped from a statistical analysis of

    existing databases.

    How to choose the correct Alarm Velocity

    Group for your machinery

    The Alarm Velocity Group (G2&4or G1&3)

    determines the instruments overall

    vibration alarm limits. Therefore, select the

    Group that best describes the general size,

    type, and speed of the machinery being

    measured. Note that these machine group

    classifications are set forth in ISO 10816-3,which rates overall velocity vibration levels

    for standardized machinery classifications.

    Groups 2&4 (default)

    ISO Group 2 and 4 classifications define the

    following type of machinery:

    Medium-sized machines and electrical

    machines with a shaft height between

    160 and 315 mm.

    These machines are normally equipped

    with rolling element bearings, but may

    use sleeve bearings, and operate atspeeds above 600 RPM.

    These machines include pumps with

    multi-vane impellers and integrated

    drivers.

    Groups 1&3

    ISO Group 1 and 3 classifications define the

    following type of machinery:

    Large machinery and electrical machines

    with a shaft height greater than 315 mm.

    These machines are generally equipped

    with sleeve bearings, but may use rolling

    element bearings.

    These machines include pumps with multi-

    vane impellers and integrated drivers.

    Rigid or Flexible foundation?

    An additional setting allows the specification

    (when defining the overall alarm levels) of

    measurements taken from machinery with

    Rigid(default) or Flexiblefoundations.

    Options are:

    G2&4R (default)

    Alert: 2.8 mm/s (0.16 ips)

    Danger: 4.5 mm/s (0.25 ips)

    G2&4F

    Alert: 4.5 mm/s (0.25 ips)

    Danger: 7.1 mm/s (0.39 ips)

    G1&3R

    Alert: 4.5 mm/s (0.25 ips)Danger: 7.1 mm/s (0.39 ips)

    G1&3F

    Alert: 7.1 mm/s (0.39 ips)

    Danger: 11.0 mm/s (0.61 ips)

    SKF Machine Condition Advisor CMAS 100-SL

    How to choose the correct Enveloped

    Acceleration Classification for your

    machinery

    The Enveloped Acceleration Classification

    (CL1, CL2,or CL3) you specify determines

    the instruments bearing vibration alarmlevels. Therefore, the Enveloped Acceleration

    Class that best describes the general size

    and speed of the bearings being measured

    should be selected.

    Options are:

    CL1

    Bearings with a bearing bore diameter

    between 200 and 500 mm and a shaft

    speed below 500 RPM.

    Alert: 1 gEDanger: 2 gE

    CL2 (default)

    Bearings with a bearing bore diameter

    between 200 and 300 mm and a shaft

    speed between 500 and 1 800 RPM.

    Alert: 2 gE

    Danger: 4 gE

    CL3

    Bearings with a bearing bore diameter

    between 20 and 150 mm and a shaft speed

    from 1 800 to 3 600 RPM.Alert: 4 gE

    Danger: 10 gE

    6

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    7/40

    Specifications (Accelerometer)

    Dynamic performanceSensitivity (10 %): 10.2 mV/(m/s 2)

    (100 mV/g)

    Measurement range: 490 m/s 2(50 g)

    Frequency range (3 dB): 0.3210 kHz

    Mounted resonant frequency: 22 kHz

    Amptitude linearity: 1 %

    Transverse sensitivity: 7 %

    Electrical

    Settling time: 2 sec

    Excitation voltage: 1830 VDC

    Excitation constant current: 220 mA Output impedance: 10 8

    Electrical protection: RFI/ESD

    Integral cable: 22 AWG, +105 C

    (22 AWG, +221 F)

    Environmental

    Shock limit: 49 km/s 2pk (5 000 g pk)

    Temperature range: 54 to +85 C

    (65 to +185 F)

    Spectral Noise

    10 Hz: 78.5 (mm/s 2)/Hz (8 g/Hz)

    100 Hz: 49.1 (mm/s 2)/Hz (5 g/Hz)

    1 kHz: 39.2 (mm/s 2

    )/Hz (4 g/Hz)

    Mechanical

    Size: 12.70 x 26.67 mm (0.50 x 1.05 in.)

    Weight (including 1.5 meter cable): 70.7 g

    (2.5 oz)

    Mounting thread: 1/4-28 UNF-2B

    Mounting torque: 2.7 to 6.8 N-m (2 to 5

    ft-lb)

    Sensing element: Ceramic/shear

    Case material: Stainless steel

    Sealing: Potted

    Wrench flats: 7/16"

    Ordering information

    SKF Machine Condition Advisor

    CMAS 100-SL includes:

    SKF Machine Condition Advisor unit

    Belt holster [CMAC 102]Charger, international DC power supply

    [CMAC 8002]

    Charger adapter, cable [CMAC 101]

    User manual, English hard copy

    [32131800-EN]

    CD containing:

    User manual available in PDF files in

    English, French, German, Portuguese,

    Spanish, and Swedish

    Link to training on SKF @ptitude

    Exchange

    SKF Machine Condition Advisor trend

    worksheet (Excel .xls file)

    SKF Reliability Systems Condition

    Monitoring Essentials catalog available

    in PDF file in English [CM2355]

    CD, Integrating Condition Monitoring

    Products and Asset Management

    Services, product catalog [CM5057]

    Accessories

    Extension kit, 100 mV/g accelerometer

    with 1.5 m integral cable and magnet

    [CMAC 105]

    Connection cable, 1.5 m with M8 sockettype connector for standard ICP 100 mV/g

    accelerometer (ICP: integrated circuit

    piezoelectric) [CMAC 107]

    Replacement

    Charger adapter, cable 4 inches,

    connector to 5.5 mm power [CMAC 101]

    Charger, international DC power supply,

    +5 V, 1 600 mA, 90264 VAC, 4763 Hz

    [CMAC 8002]

    Magnet, magnet base, 0,75 diameter, 10

    lbs pull-strength [CMAC 106]Belt holster [CMAC 102]

    Optional kits that includes the SKF

    Machine Condition Advisor, CMAS 100-SL

    SKF Basic Condition Monitoring kit

    [CMAK 400]

    SKF Bearing Analysis kit [CMAK 300]

    Typical sensitivity deviation vs. temperature

    Sensitivity

    Deviation

    (%)

    Temperature, C (F)

    73 18 +38 +93 +149(100) (0) (+100) (+200) (+300)

    +20

    +10

    0

    10

    20

    SKF Machine Condition Advisor CMAS 100-SL

    Expanding your capabilities with SKF Machine Condition Advisor compatible

    accessories

    External sensor kit Model CMAC 105

    The Extension sensor kit CMAC 105

    contains an accelerometer with integralcable and everything needed to take

    measurements from hard-to-reach places.

    Accelerometer

    100 mV/g sensitivity

    Small size case, 0.5 x 1.05

    Small footprint, 0.5

    0.32 Hz to 10 kHz frequency range

    (3 dB)

    Waterproof

    Integral cable (1.5 meters)

    Connector to SKF Machine Condition

    Advisor CMAS 100-SL

    Magnet, Model CMAC 106

    10 lbs pull-strength, 0.75" diameter

    Each accelerometer is fully enclosed in a

    potted and waterproof stainless steel case.

    Connection cable (1.5 meters) Model

    CMAC 107

    Optional Connection cable for standard ICP

    accelerometers with 100 mV/g, mil-spec

    connector.

    7

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    8/40

    LCD display

    Dual laser sighting and distance to spot

    ratio

    Dual Lasers provides easy aiming and

    defines the target area. The target area ishighlighted at all distances with two laser

    dot markers. Laser 1 indicates one point of

    the measurement spot on one side of the

    target area to be measured and Laser 2

    indicates the location of the diametrically

    opposed point on the other side of the

    measurement spot. At the focal point, where

    the spot size is the smallest, the dots line up

    vertically, rotating as the SKF Infrared

    Thermometer is moved closer or further

    from the target.

    Distance to spot ratio 50:1.

    SKF Infrared ThermometerCMSS 3000-SL

    Heavy duty, long range, dual laser sighted non-contact infrared thermometer

    Features

    Dual point laser sighting

    Adjustable emissivity

    50:1 Distance to spot size ratio

    Temperature range: 60 to +1 000 C

    (76 to +1 832 F)

    Exceptional battery life

    High and low alarm

    MAX, MIN, DIF, AVG temperature displays

    Amber back-light LCD display

    High intensity white LED flashlight

    Heavy duty magnet in base of handle Hard case

    Introduction

    There are many uses for this hand-held

    non-contact, infrared thermometer. Rugged

    and easy to use just aim, pull the trigger,

    and read the temperature in less than a

    second. Measures surface temperatures of

    hot, hazardous, moving, or hard-to-reach

    objects safely without contact.

    The non-contact thermometer senses the

    thermal energy radiated from an object with

    an infrared detector. When pointed at anobject, the infrared detector collects energy

    producing a signal that the microprocessor

    translates as a reading on the backlit display.

    As the trigger is squeezed, the object

    temperature is continuously measured by

    the infrared detector. This allows for fast and

    accurate real-time readings.

    This instrument features an extended

    temperature range 60 to +1 000 C (76

    to +1 832 F); dual laser sighting; bright

    large amber back-light LCD display;

    Maximum, Minimum, Difference (MAX-MIN)and Lock function for continuous

    temperature scanning; programmable High

    and Low audible alarms; selectable

    temperature units (C or F); low battery

    indicator and adjustable emissivity for more

    accurate temperature measurements.

    Emissivity

    Lock functionfor continuous

    temperaturescanning

    Laser functionON/OFF

    Surfacetemperature

    Set valueof emissivity

    Selectedtemperature unit(degrees Celsius/Fahrenheit)

    Battery lowindicator

    Scanningin progress

    EmissivityEmissivity is a term used to describe the

    energy-emitting characteristics of materials.

    Most organic materials and painted or

    oxidized surfaces have an emissivity of 0.95.

    Inaccurate readings can result from

    measuring shiny or polished metal surfaces.

    To compensate for this, adjust the units

    emissivity reading, or cover the surface to be

    measured with masking tape or flat black

    paint (< +148 C /+300 F). Allow time for

    the tape or paint to reach the same

    temperature as the material underneath it.Measure the temperature of the tape or

    painted surface.

    Hard case

    A water resistant, dust-proof case which

    holds the unit (and magnetic stand) and

    measures 330 x 197 x 66 mm (13.00 x

    7.75 x 2.60 in.) is included.

    2.4 in. at120 in.

    Target area

    Laser 2Laser 1

    Focal point

    1.6 in. at80 in.

    0.04 mat 2 m0.06 m

    at 3 m

    8

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    9/40

    Specification

    Measurement range: 60 to +1 000 C

    (76 to +1 832F)

    Operating range: 0 to +50 C (+32 to

    +122 F)

    Accuracy (T object= 15-35 C, Tambient=25 C): 1.0 C (1.8 F)

    Accuracy (T object=33-1,000 C; Tambient=

    23 3 C): 2 % of reading or +2 C

    (+4F) whichever is greater

    Update frequency: 1.4 Hz

    Wave length response: 8-14 m

    Emissivity range: 0.95 default

    adjustable 0.1 to 1 step .01

    Relative humidity: 5 to 95 %

    non-condensing

    Resolution (from -9.9 to +199.9 C):

    0.1 C /0.1 FResponse time (90 %):

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    10/40

    Features

    Detect pressure and vacuum leaks

    including compressed air

    Check steam traps and valves quickly and

    accurately

    Detect arcing, tracking and corona in

    electric apparatus

    Test bearings, pumps, motors,

    compressors, etc.

    Introduction

    The SKF Inspector 400 Ultrasonic Probesenses high frequency sounds produced by

    operating equipment, leaks and electrical

    discharges. It electronically translates these

    signals by a heterodyning process, making

    them audible, so that a user can hear these

    sounds through a headset and see them as

    intensity increments on a meter.

    The SKF Inspector 400 Ultrasonic Probe

    can complement your condition

    monitoring program by providing you with

    the following capabilities:

    Pressure/vacuum leaks

    As any gas (air, oxygen, nitrogen, etc.)

    passes through a leak orifice, it generates a

    turbulent flow with detectable high

    frequency components. By scanning the

    test area with the SKF Inspector 400

    Ultrasonic Probe, a leak can be heard

    through the headset as a rushing sound or

    noted on the meter bar graph indicator. The

    closer the instrument is to the leak, the

    louder the rushing sound and the higher

    the meter reading. Should ambient noise be

    a problem, a rubber focusing probe may beused to narrow the instruments reception

    field and to shield it from conflicting ultra

    sounds.

    Valve

    Valve activity such as leakage or blockage

    can be accurately checked while the valve is

    on line. Properly seated valves are relatively

    quiet while leaking valves produce a

    turbulent flow as the fluid moves from the

    high pressure side through the leak to the

    low pressure side. Due to a wide sensitivity

    SKF Inspector 400 Ultrasonic ProbeCMIN 400-K

    and ultrasonic frequency, all

    types of valves even in noisy

    environments can be accurately tested.

    Valve stems

    Valve stems may be quickly tested for leaks

    to atmosphere.

    Steam trap inspection

    Major steam trap manufacturers have

    recommended ultra sound inspection of

    steam traps as one of the most reliablemethods available. By converting theultrasonic elements of a working steam trap

    into the audible range, the SKF Inspector

    400 Ultrasonic Probe allows users to hear

    through headphones and see on a meter

    the exact condition of a steam trap while it

    is on line. Blowby, machine gunning,

    oversized traps or line blockage are all

    easily detected.

    The SKF Inspector 400 Ultrasonic Probe

    markedly reduces confusion from

    extraneous sounds or from heat transfer,

    even when traps are extremely closetogether.

    Electrical inspection

    Arcing and corona discharge emit ultra

    sounds at the site of emission. This

    electrical discharge can be located quickly

    by scanning the area with the SKF Inspector

    400 Ultrasonic Probe. The signal is heard as

    a frying or buzzing sound in the headset. As

    Valve leakage. Pressure/vacuum leaks.

    with pressure or vacuum leak detection, the

    closer the instrument is to the discharge,

    the more intense the signal.

    Test switch gear, transformers, circuitbreakers, buss bars, relays, junction boxes,

    insulators, and other electrical gear.

    General mechanical inspection

    The SKF Inspector 400 Ultrasonic Probe

    can detect the early stage of a machines

    mechanical malfunction. NASA research

    has demonstrated that ultrasound

    monitoring will locate potential bearing

    10

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    11/40

    Mechanical inspection.

    Heat exchangers, boilers and condensers

    In-leakage or pressure leakage can be

    readily located with the SKF Inspector 400

    Ultrasonic Probe. Fittings, valves, flanges

    are all easily scanned for leakage. The high

    frequency, short wave nature of ultrasoundallows operators to pinpoint the location of

    a leak in high noise environments.

    Condenser tubes and heat exchanger

    tubes may be tested for leakage through

    two (2) methods: Vacuum and Pressure.

    Vacuum

    The tube sheet is scanned for the telltale

    rushing sound produced as the leak draws

    air into the tube.

    Pressure

    Additional testing may be performed when

    the system is off-line utilizing air pressure

    around the tube bundle and scanning for

    the rushing sound produced from the

    leaking tube.

    Applications

    Pressure and vacuum leak detection

    Valve seat leak detection

    Exhaust system leaks

    Heat exchangers, boilers, condensers

    Steam trap inspection

    Bearing testingGear/gear box inspection

    General mechanical inspection and

    troubleshooting

    Tanks, pipes, etc., leak testing

    SKF Inspector 400 Ultrasonic Probe CMIN 400-K

    deficiencies before they are detected by the

    traditional heat and vibration methods.

    With the SKF Inspector 400 Ultrasonic

    Probe, users hear the sound quality of a

    bearing as well as monitor amplitude

    changes on the meter. This complementsother monitoring instruments and adds to

    the ability to trend, troubleshoot and

    confirm potential bearing problems.

    General mechanical inspection is easy with

    the SKF Inspector 400 Ultrasonic Probe and

    with very little training, users can learn to

    test bearings within minutes. Current

    vibration programs can achieve enhanced

    diagnostic ability with the SKF Inspector

    400 Ultrasonic Probe.

    Prevent over-lubrication with the SKF

    Inspector 400 Ultrasonic Probe by simplylubricating only until the meter reaches a

    specified level. Over lubrication is one of the

    more common causes of bearing failure.

    General mechanical inspection of pumps,

    motors, compressors, gears and gear

    boxes: All types of operating equipment

    may be inspected with the SKF Inspector

    400 Ultrasonic Probe. Since the SKF

    Inspector 400 Ultrasonic Probe works in a

    high frequency, short wave environment,

    problems such as cavitation in pumps,

    compressor valve leakage or missing gear

    teeth may be heard and isolated.Reciprocating compressor valve analysis

    has also become successful with the SKF

    Inspector 400 Ultrasonic Probe and

    therefore many engine analyzer companies

    now offer instruments with an ultrasonic

    input port.

    Tank leakage.

    Available SKF Inspector 400 Ultrasonic

    Probe Stethoscope/Scanner kit includes:

    SKF Inspector 400 Ultrasonic Probe

    pistol housing with LED bar graph meter,

    8-position sensitivity selection, low

    battery indicator

    Scanning module

    Rubber focusing probe

    Stethoscope module

    Lightweight foam lined headset

    9 volt alkaline battery (replaceable)

    Cordura/nylon soft pack carrying case

    Comprehensive instruction manual

    (English language)

    11

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    12/40

    Ordering information

    SKF Inspector 400 Ultrasonic Probe

    Stethoscope/Scanner Kit [CMIN 400-K]

    Accessories and replacement parts

    Lightweight foam lined headset[CMAC 8600-1]

    Deluxe noise isolating headphones

    [CMAC 8600-2]

    Deluxe noise isolating headphones to be

    worn with hard hat [CMAC 8600-3]

    Utility belt with holster [CMAC 8600-4]

    Patented liquid leak amplifier, case of 12 x

    8 oz bottles, (used for extremely low level

    leaks 1 x 10-6mil/sec) [CMAC 8600-5]

    Stainless steel unisonic scanning module

    [CMAC 8600-6]

    Stainless steel stethoscope/contact module [CMAC 8600-7]

    Stethoscope extension rods

    [CMAC 8600-8]

    Rubber focusing probe [CMAC 8600-9]

    SKF Inspector 400 Ultrasonic Probe CMIN 400-K

    Specifications

    Construction: Hand-held ABS pistol type

    ultrasonic processor, stainless steel

    sensor enclosures

    Circuitry: SMD/solid state hybrid

    heterodyne receiverFrequency response: 20-100 kHz

    (centered at 38-42 kHz)

    Indicator: 10 segment LED bar graph

    (red)

    Sensitivity selection: 8-position precision

    attenuation

    Power: 9 volt alkaline battery

    Low battery voltage indicator: LED

    Headset: Lightweight foam lined double

    headset wired monophonic impedance;

    16 ohms

    Probes: Scanning module stainless steel unisonic (single transducer) piezoelectric

    crystal type; stethoscope/contact module

    stainless steel plug-in type with 5.5 inch

    stainless steel waveguide

    Rubber focusing probe: Shields stray

    ultrasonic signals and focuses detected

    signals

    Response time: 300 millisec

    Ambient operating temperature range:

    0 to +50 C (+32 to +120 F)

    Relative humidity: 10 to 95 %

    noncondensing at up to +30 C (+86 F)

    Storage temperature: 18 to +54 C(0 to +130 F)

    Dimensions:

    Height: 133 mm (5.25 in.)

    Width: 50 mm (2.00 in.)

    Length: 203 mm (8.00 in.)

    Weight: 320 g (11 oz)

    Carrying case: Cordura/nylon soft pack

    with die cut foam

    Optional kits that includes the SKF

    Inspector 400 Ultrasonic Probe

    CMIN 400-K

    SKF Basic Condition Monitoring kit

    [CMAK 400]SKF Machine Condition Advisor

    [CMAS 100-SL]

    SKF Infrared Thermometer

    [CMSS 3000-SL]

    SKF Inspector Ultrasonic Probe

    [CMIN 400]

    SKF Basic Condition Monitoring Kit

    (metric system) [CMPK 200plus]

    SKF Vibration Pen plus[CMVP 50-EN]

    SKF Infrared MicroTemp Non-contact

    Thermometer [CMSS 2020-SL]

    SKF Inspector Ultrasonic Probe

    [CMIN 400-K]

    Basic Condition Monitoring Kit (english

    system) [CMPK 210plus]

    SKF Vibration Pen plus[CMVP 40-EN]

    SKF Infrared MicroTemp Non-contact

    Thermometer [CMSS 2020-SL]

    SKF Inspector Ultrasonic Probe

    [CMIN 400-K]

    12

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    13/40

    ATEX APPROVEDThe SKF Machine Condition Detector Pro IS provides for velocity, enveloped acceleration, andtemperature monitoring with general alarm capabilities and has ATEX Certifications.

    identifies phenomena which are observable

    in the low to mid frequency range, and

    indicates such structural problems asmisalignment, unbalance, mechanical

    looseness and more. However, events

    which occur in the higher frequency ranges

    such as bearing and gear problems, can

    also be detected by the SKF Machine

    Condition Detector Pro IS with its

    Acceleration Enveloping capability, a signal

    processing technique which focuses on

    enhancing the repetitious vibration signals

    that characterize such problems.

    Temperature

    Temperature measurements enhance the

    early warning benefit of the instrument by

    offering a useful indication of mechanical

    condition or the load applied to a specific

    component, since, as a bearing or its

    lubrication fails, friction causes its

    temperature to rise.

    The SKF Machine Condition Detector Pro IS

    is certified Intrinsically Safe (IS) for Europe

    and North America. The ruggedized SKF

    Machine Condition Detector Pro IS is ideal

    for use in the hazardous environments

    typically found in the petrochemical

    Industrial marketplace.

    Go / No Go machine monitoring

    The SKF Machine Condition Detector Pro IS

    is designed to provide a straightforward

    approach to machinery monitoring. Theinstruments sensor affixes to a machine

    point via a SKF MARLIN QuickConnect Stud

    or magnetic bases for automatic collection

    of vibration and temperature data. Green,

    yellow and red LEDs provide easy-to-

    interpret indications of machine status, so

    operations or maintenance personnel can

    quickly identify the need for more in-depth

    analysis on a particular machine.

    Multi-parameter monitoring capabilities

    The SKF Machine Condition Detector Pro IS

    operates as a stand-alone device, or as anaccessory to the SKF MARLIN hand-held

    mobile computers for Operator Driven

    Reliability (ODR). When used with SKF

    @ptitude Inspector companion software

    and the SKF MARLIN QuickConnect line of

    mechanical and computerized studs, the

    complete system offers customers in non-

    hazardous conditions the added power and

    functionality of immediate in-the-field

    feedback on alarm conditions, as well as

    data storage, trending and analysis. Data is

    logged for trending, Statistical ProcessControl (SPC) rule violation, and percent

    change from last measurement and

    baseline data.

    SKF Operator Driven Reliability

    (ODR) process ensures that operator

    observations are accurately, thoroughly, andconsistently recorded and communicated.

    Utilizing automated technology that is

    linked to your maintenance strategy,

    operators immediately respond to abnormal

    process conditions, proactively, with in-the-

    field corrective actions that help increase

    production output. In the event of

    degrading asset health, operators can

    initiate work notifications to your

    computerized maintenance management

    system (CMMS), providing enhanced

    awareness to maintenance management.

    Vibration monitoring

    When performing measurements, the SKF

    Machine Condition Detector Pro ISs sensor

    input signal is processed to produce two

    vibration measurements for each

    measurement POINT. Velocity vibration

    ATEX

    SKF MARLIN Condition Detector Pro ISCMVL 3600-IS

    Machine Reliability Inspection System, Intrinsically Safety (IS) rated

    13

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    14/40

    SKF MARLIN Condition Detector Pro IS CMVL 3600-IS

    General alarm capabilities

    When used as a stand-alone tool, the SKF

    Machine Condition Detector Pro IS may be

    easily programmed for six alarm settings,

    which include the alert and danger levels

    for each of the three measurements. Whenmeasurements are taken, current

    measured values are automatically

    compared to six user-defined settings, and

    the SKF Machine Condition Detector Pro ISs

    alarm indicator and LED react appropriately.

    An alert condition provides a user with an

    early warning of impending problems for

    which immediate in depth analysis should

    be performed. A danger alarm indicates

    that a problem has escalated to a point

    where actions must be made quickly to

    avoid a serious failure.

    SKF MARLIN QuickConnect studs for

    quality, repeatable data collection

    Specially designed mechanical and

    computerized studs enable one or several

    users to collect consistent, accurate, and

    repeatable data from each measurement

    point. Engineered to work exclusively with

    the SKF Machine Condition Detector Pro IS,

    the SKF MARLIN QuickConnect mechanical/

    computerized studs provide for a fast,

    quarter turn connection which temporarily

    fastens the probe to a measurement point.This reduces the possibility of errors and

    inconsistencies often resulting from data

    collected by a variety of individuals using

    varying methodologies.

    Specifications

    Measurements

    Vibration pickup: Integrated piezoelectric

    acceleration (ceramic, shear type)

    Measurement range:Velocity: 0.355 mm/s (RMS), 0.02

    3.00 in/s (equivalent Peak). Meets

    ISO Standard 10816-1.

    Enveloped acceleration: 0.320.0 gE

    Temperature: 0 to +100 C (+32 to

    +212 F)

    Frequency range:

    Overall velocity: 10 Hz1 kHz

    (Tolerances measured within the

    frequency range are in accordance

    with ISO 3945)

    Enveloped acceleration band 3:

    500 Hz10 kHz

    Display

    Viewing area: 54.99 x 17.78 mm

    (2.165 x 0.700 in.)

    Power

    Main power: Two (2) 1.5 V alkaline AA

    batteries

    Battery lifetime: 30 hours

    Backup battery: One (1) 3 V BR1225

    Lithium ion battery

    Auto off: Two (2) minute countdown onlast operation

    Hazardous area ratings

    Intrinsic Safety (IS):

    ATEX: II1G EEx ia IIC T4

    (Ta = 20 to +40 C)

    Class I, Division 1, Groups A, B, C, D

    T3A (USA, Canada)

    Physical characteristics

    Case: Water and dust resistant (IP 65)

    Drop test: Six (6) feet on multiple axes

    Dimensions:Length: 190.5 mm (7.50 in.)

    Width: 43.2 mm (1.70 in.)

    Height: 41.4 mm (1.63 in.)

    Weight: 431 gms (0.95 lb) with battery,

    635 gms (1.4 lb) with temperature

    magnet probe tip

    User environment

    Operating temperature:

    20 to +60 C (4 to +140 F) ordinary

    locations

    20 to +40 C (4 to +104 F)

    hazardous locations

    Storage temperature: 37 to +70 C (34

    to +158 F)

    Humidity: 5 to 95 % noncondensing

    Communications port

    Type: Micro D RS-232

    QuickConnect interface

    Receptacle: 1/4 turn 5/8-24 two (2) lead

    thread with contact

    Accessories to fit:

    SKF MARLIN QuickConnect:

    QuickConnect Stud series

    CMSS 26xx Temperature Magnet

    10 cm (4) Stinger: CMSS 60139-04

    14

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    15/40

    SKF MARLIN Condition Detector Pro IS CMVL 3600-IS

    Ordering information

    SKF Machine Condition Detector MCD

    Pro IS

    SKF Machine Condition DetectorCMVL 3600-IS-K-01-C Kit

    Each CMVL 3600-IS-K-01-C Kit consists of

    the following items:

    SKF Machine Condition Detector Pro IS

    probe [CMVL 3600-IS]

    SKF MARLIN QuickConnect 1/4-28 stud,

    one (1) [31706301]

    Temperature magnet for SKF Machine

    Condition Detector Pro IS probe

    [CMAC 3610]

    Stinger probe 4 (10 cm) [CMSS 60139-04]

    AA Alkaline batteries, two (2)

    SKF Machine Condition Detector Pro IS

    setup key [CMAC 3620]

    SKF Machine Condition Detector Pro IS

    padded carrying Case [31736700]

    SKF Machine Condition Detector Pro IS

    user manual [CMVL 3600M-SL]

    SKF Machine Condition Detector Pro IS

    quick start card [CMVL 3600-QS]

    Optional accessories

    Cable, SKF MARLIN I-Pro to SKF Machine

    Condition Detector Pro IS [CMAC 6107]

    SKF Machine Condition Detector Pro ISsetup key [CMAC 3620]

    Temperature magnet for SKF Machine

    Condition Detector Pro IS probe

    [CMAC 3610]

    Probe tip replacement kit for temperature

    magnet for SKF Machine Condition

    Detector Pro IS [CMAC 3630]

    Magnetic probe tip for SKF Machine

    Condition Detector Pro IS [CMAC 3611]

    Stinger probe 10 cm (4)

    [CMSS 60139-04]

    1/4-28 MQC (MARLIN QuickConnect) for stinger interface [CMSS 2610-1]

    SKF Machine Condition Detector Pro IS

    quick start card [CMVL 3600-QS]

    SKF Machine Condition Detector Pro IS

    user manual [CMVL 3600M-SL]

    SKF MARLIN data manager

    The SKF Machine Condition Detector Pro

    IS can be used in non-hazardous

    conditions with the following SKF

    MARLIN data managers as well as all

    international language translation kits:

    SKF MARLIN I-Pro CS, Bar Code Scanner

    [CMDM 6210]SKF MARLIN I-Pro NI2, Bar Code Imager,

    NI (Non-incendive) Class I Division 2

    [CMDM 6220]

    SKF MARLIN I-Pro NIA, Bar Code Imager,

    NI (Non-incendive) ATEX Zone 2

    [CMDM 6230]

    SKF MARLIN S-Pro IS data manager,

    ATEX Zone 1 [CMDM 5360]

    SKF MARLIN QuickConnect and mounting

    accessories

    SKF MARLIN QuickConnect mechanical

    M8 x 1.25 mounting thread three (3)studs per package [CMSS 2600-3]

    SKF MARLIN QuickConnect mechanical

    1/4-28 mounting thread three (3)

    studs per package [CMSS 2610-3]

    SKF MARLIN QuickConnect computerized

    (patent pending) M8 x 1.25 mounting

    thread three (3) studs per package

    [CMSS 2601-3]SKF MARLIN QuickConnect computerized

    (patent pending) 1/4 x 28 mounting

    thread three (3) studs per package

    [CMSS 2611-3]Tool kit for spot face 1/4-28

    [CMAC 9600-01]

    Tool kit for spot face M8 x 1.25

    [CMAC 9600-02]

    Drill bit for 1/4-28 kit [CMAC 9600-03]

    Tap for 1/4-28 kit [CMAC 9600-04]

    Pilot for 1/4-28 kit [CMAC 9600-05]

    Drill bit for M8 x 1.25 kit

    [CMAC 9600-06]

    Tap for M8 x 1.25 kit [CMAC 9600-07]

    Pilot for M8 x 1.25 kit [CMAC 9600-08]

    End mill or counter bore for either kit

    [CMAC 9600-09]

    15

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    16/40

    Now available in multiple languages (ML):

    English, Chinese, German and Spanish.

    With the SKF MicroVibe P, vibration

    assessment is as close and convenient as

    your PDA! This economical vibration meter

    expansion module fits in a PocketPCs

    compact flash card slot (CF Type II) and

    features the user-friendly WindowsMobile

    Operating System. Identify problems and

    assess machine condition quickly and easily

    with this versatile and easy-to-use pockettool.

    Power without complexity

    A handy quick-check solution, based on

    the universal PDA platform, SKF MicroVibe

    P is simple to use. Built-in automatic

    functions virtually eliminate setup, while the

    analytical displays and automatic judgment

    of machine vibration readings help users

    identify machine problems on the spot!

    Features

    Exceptional valueLow cost, compact, lightweight, works

    with many Pocket PC PDAs by Hewlett-

    Packard, Dell, Toshiba, etc.

    Quickly identify problems

    Expert judgment criteria based on ISO

    vibration severity standard and SKF

    bearing evaluation

    The SKF MicroVibe P system.

    SKF MicroVibe PCMVL 3850-ML

    Power without complexity, an advanced instrument forsimplified vibration assessment that fits in your pocket.

    FFT Spectrum analysis enables

    user to pinpoint problems likeunbalance, misalignment, bearing,

    rubs, etc.

    Multi-point automation

    Standard vibration measurements

    Envelope acceleration,

    acceleration, velocity,displacement, time waveform, and

    FFT spectrum analysis

    Store and recall measurements

    For trending and analysis, store

    up to 2,000 overall vibration

    signals, 1,000 FFT spectrum, and

    200 time waveforms

    Data management software

    Enables users to transfer

    machinery vibration data to a computer

    for trending and further analysis

    SKF MicroVibe P kit includes:

    SKF MicroVibe P module, data

    management software, accelerometer

    and cable, magnetic base, earphones,

    user manual, and carrying case

    (everything but the PDA).

    An advanced instrument for simplified

    vibration assessment

    The SKF MicroVibe P collects and displays

    overall vibration readings and automatically

    provides expert judgment of the measured

    velocity and overall enveloped acceleration

    levels, enabling immediate, accurate and

    reliable assessment of machine or bearing

    condition.

    Multi-point automation saves time and

    improves reliability

    Automatically collect the most useful

    measurements for vibration analysis

    acceleration, velocity, displacement, and

    enveloped acceleration simultaneously.SKFs multi-point automationsaves time

    and enhances the power, accuracy and

    overall reliability of your decision making

    giving you the information needed to make

    the best possible judgment call.

    16

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    17/40

    FFT spectrum analysis capabilities

    With pre-set measurements and user

    selectable FFT resolution at 400, 800 or

    1600-lines, selectable Fmax and a 90 db

    dynamic range, the SKF MicroVibe P has

    what it takes to help you easily pinpointimpending machine problems. Cursor

    position readout with display zoom

    optimizes your analysis power. In addition, it

    automatically tabulates and displays the

    highest vibration peaks from a spectrum,

    making it easy to quickly identify signals

    indicative of specific machine problems, like

    misalignment, imbalance or bearing faults.

    Automatic setup and onboard expertise

    The MicroVibe P provides extensive

    automatic setup and evaluation of vibration

    results. Simply collect the data and the SKF

    MicroVibe P does the rest comparing

    readings to pre-programmed velocity andenveloped acceleration severity criteria for a

    reliable and accurate evaluation of vibration

    severity. This allows even novice users to

    easily determine abnormal conditions and

    take appropriate action.

    Time-waveform displays

    Measure and store time data, with the

    capability to select acquisition type and time

    measurement. Time displays in acceleration,

    velocity, displacement or enveloped

    acceleration. A unique automatic transientcapture function starts taking

    measurements when the signal exceeds a

    user-specified trigger level, enabling more

    detailed analysis of the pre- and post-

    trigger events surrounding a change in

    machine condition.

    Versatile measurement capability

    The SKF MicroVibe P works with the two

    most commonly used vibration sensors

    accelerometers and dynamic velocity

    transducers. Both enable you to take a

    multi-parameter approach to your analysis

    and to optimize vibration data gathering.

    Audio analysis

    Now you can actually listen to machine

    problems using the SKF MicroVibe Psacoustic capability. Simply connect the

    earphones and listen to the operation of

    your machine. When abnormal noise is

    detected, use the vibration analysis

    capabilities of the SKF MicroVibe P to zero in

    on the problem.

    SKF MicroVibe P CMVL 3850-ML

    17

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    18/40

    _

    1.5 m(5 ft)

    40 mm(1.57 in)

    20 mm(0.79 in)

    Store and recall measurements for

    trending and analysis

    The SKF MicroVibe Ps data storage capacity

    is also extraordinarily impressive. It can

    store up to 2 000 overall vibration signals,

    1 000 FFT spectrums or 200 records oftime waveform data for later recall. A search

    function retrieves specific measurement

    points and a repeat measurement lets you

    recall and repeat any measurement for

    more focused analysis or trending of a

    potential problem. Finally, a recall data

    storage list helps you keep track of and

    reference all collected data.

    Data management and software for your

    desktop computer

    The SKF MicroVibe P offers addedfunctionality, including a software program

    to extract, save, edit and display collected

    data. Its ideal for small route data collection.

    For further analysis and trending, data

    may be uploaded to your desktop computer

    using the Data Management software. Once

    uploaded, vibration data, overall trends and

    spectra can be stored, trended, graphically

    displayed and even exported to Excel.

    Utilities add value

    Several exciting utilities help make the SKF

    MicroVibe P an universal tool for machine

    vibration analysis, for any level of expertise.

    Collect data in english or metric units or

    reference a dictionary of vibrationterminology.

    The SKF MicroVibe P truly brings you

    vibration monitoring and analysis power

    without complexity. Its tomorrows big

    solution for vibration analysis in a small,

    smart package and its available today! Get

    more information at www.skf.com/cm.

    Specifications

    SKF MicroVibe P CMVL 3850-ML

    Minimum PDA requirements(*): Conforms to the Pocket PC specifications

    Operating system: Microsoft Windows

    Mobile 3.0/5.0

    Processor: ARM processor

    Interface: Compact Flash TYPE II Slot 3.3

    V only

    Recommended specifications:

    Processor: PXA255 400 MHz or higher

    Memory (RAM): 64 MB or higher

    Interface with Pocket PC: Compact Flash

    TYPE II, slot 3.3 V only

    Power supply: +3.3 V (supplied by Pocket

    PC)Current:

    Standby: 44 A

    Under measurement: 48 mA

    Pickup input (PU IN):

    AC voltage signal: Maximum 2.5 V

    Input terminal: 8-pin modular jack

    (RJ-45), ICP type pre-amp built-in

    accelerometer is not connected.

    Raw waveform output (PU OUT):

    AC voltage signal: Maximum 2.5 V

    Output terminal: Mini-jack (2.5 mm F)

    Sampling frequency: Maximum 76.8 kHz

    (changes according to mode) 76.8 kHz/

    38.4 kHz

    Aliasing filter: 20 kHz/2 kHz (changes

    according to mode and sampling

    frequency)

    A/D: 16-Bit

    Temperature range: 0 to +45 C (+32 to

    +113 F)

    Humidity range:

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    19/40

    Ordering Information

    SKF MicroVibe P Kit CMVL 3850-ML

    includes:

    SKF MicroVibe P Module

    Accelerometer, 1.5 meters (5 feet) integral

    cable, with plug, and stinger one (1) each

    [CMSS 3811]

    Two-Bar Magnetic Base, high strength

    35 lb. pull, one (1) each [CMAC 3825]

    Earphones, one (1) each [CMAC 3830]

    Data Management software CD-ROM,

    one (1) each

    SKF MicroVibe P documentation (English

    and German)

    User manual (PDF)

    Data management software manual

    (PDF)

    Quick start guide (PDF)

    CE declaration of confirmation

    Carrying case

    Note: Pocket PC (PDA) NOT INCLUDED.

    Frequency specifications FFT specifications

    Measurement Specifications

    (For measurement with CMSS 3811 Accelerometer)

    Overall and judgment specifications

    Display specifications

    Item Specifications

    Frequencyrange

    AVDE1E2E3E4

    Acceleration: 10~15 kHz (*1)Velocity: 10~1000 HzDisplacement: 10~150 HzEnvelope Detection: 5~100 HzEnvelope Detection: 50~1 kHzEnvelope Detection: 500~10 kHzEnvelope Detection: 5 k~20 kHz

    Samplingfrequency

    A, E3, E4: 76.8 kHzE1, E2, V, D: 38.4 kHz

    Aliasingfilter

    A, E3, E4: 20 kHzE1, E2, V, D: 2 kHz

    RangeA, E1, E2,

    E3, E40~1 g: (100x range)0~5 g: (20x range)0~20 g: (5x range)0~100 g: (1x range)

    V 0~10 mm/s: ( 100x range)0~50 mm/s: (20x range)0~200 mm/s: (5x range)0~1000 mm/s: (1x range)

    D 0~50 m: (100x range)0~250 m: (20x range)0~1000 m: (5x range)0~5000 m: (1x range)

    Item Specifications

    Overall valuesimultaneousmeasurement

    Simultaneous measurement ofoverall vibration level, multi-mode(A, V, D, E1~E4)

    Range = AutoMeasuring Time = 0.1 s; 0.5 s;

    1.0sMeasurement data = RMS value,

    PEAK value, C. F. valueMeasured value display digits:

    Significant figure 4 digitsExample: .9999/ 999.9/ 99.99/

    9.999Status Display (Under

    measurement, measurement end)

    Judgment Abnormal judgment by vibrationseverity standard (ISO 10816

    [JIS-B-0906] Standard)Abnormal bearing judgment by

    enveloped acceleration E3 mode

    Item Specification

    Graphdisplay

    FFT graph: Dominant frequency component

    (highest 5 frequencies) Cursor indication value display Zoom scroll value displayWaveform graph: Cursor indication display Zoom scroll display

    Item Specifications

    FFT,waveformanalysis

    Mode = A/ V/ D/ E1/ E2/ E3/ E4Range = Fixed/autoFFT measurement condition:

    Analysis frequencies: Selection list A: 250/ 500/ 1k/ 2k/ 5k/ 10k/ 15k/30k Hz V: 250/ 500/ 1k Hz D: 250 Hz/(500 Hz for CMSS 3812Velocity Sensor only) E1: 50 Hz E2: 250/ 500 Hz E3: 250/ 500/ 1k/ 2k/ 5k Hz E4: 250/ 500/ 1k/ 2k/ 5k/ 10k HzLines of resolution: 1600/ 800/ 400Averaging: Stable/exponential/peakhold 1/ 2/ 4/ 8 timesWindow: Hanning

    Measurement mode:Normal/ recorder/ post process

    Normal: Recording time ofwaveform data is determined by FFTmeasurement condition (analysisfrequency, line number). Executesthe measurement for average cyclein FFT and records the waveform forframe time (final frame time). Recorder: Records the waveform ofspecified time by Rec. time. Averagecycle of FFT is one time. Rec. Time: 1/ 2/ 5/ 10 sec Post-process: Calculates from rawwaveform data (temporary saveddata). Average cycle of FFT is onetime.

    SKF MicroVibe P CMVL 3850-ML

    Additional Accessories

    Accelerometer, 1.5 meters (5 feet) integral

    cable (replacement), with plug, and

    stinger, one (1) each [CMSS 3811]

    Velocity Pickup Sensor, 1.5 meters (5 feet)

    integral cable, with plug, one (1) each

    [CMSS 3812]

    Two-Bar Magnetic Base, high strength 40

    lb pull, one (1) each [CMAC 3825]Earphones, one (1) each [CMAC 3830]

    Certified Pocket PC PDAs with Windows

    Mobile2003/2005

    Certified Pocket PC PDAs with Windows

    Mobile2003

    Hewlett Packard

    iPAQ hx2400

    iPAQ hx2700

    iPAQ hx2750

    iPAQ hx4700

    Toshiba

    e830

    ASUS MyPal A730

    Dell AXIM X50 (NOT 51)

    Compatible Pocket PC PDAs with Windows

    Mobile2003

    Hewlett Packard

    iPAQ h2210

    iPAQ h2215

    Toshiba

    e800

    Certified Pocket PC PDAs with Windows

    Mobile2005

    Hewlett Packard

    iPAQ hx2490

    iPAQ hx2790

    (*1) The upper bound frequency can be changedby Utili ty Menus A Filter.

    19

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    20/40

    Features

    Solid-state reliability

    Integral sensor

    4-20 mA output

    Dynamic signal output or temperature

    4-20 mA output

    Description

    The CMSS 420 Series are solid state, loop-

    powered vibration transmitters. They

    provide a 4-20 mA output that is

    proportional to overall vibration in terms ofvelocity. The series of CMSS 420

    continuously monitor machinery health and

    transmit directly into a PLC or DCS for

    trending, alarm and machine shutdown. In

    addition, the CMSS 420VT provides access

    to the dynamic transducer output. The

    buffered output is available for temporary

    connection of portable analyzers for

    detailed machine fault analysis.

    Simple installation

    Simply mount the CMSS 420VT into a

    1/4-28 or M8 tapped hole in the bearinghousing or machine case (NPT Mounting

    Adapters are available, part number CMSS

    203), connect two wires into a 4-20 mA

    loop, and you are ready to interface with a

    PLC or DCS. Electrical conduit may be

    connected directly to the top 3/4 NPT

    fitting, (NPT Mounting Adapters are

    available, part number CMSS 203).

    Specifications

    Dynamic

    Output: 4-20 mA proportional to full

    scale Velocity

    Accuracy: 5 % of full-scale

    Frequency response: 2-2 000 Hz

    Frequency response accuracy:

    3 db: 2 Hz to 2 kHz

    10 %: 10 Hz to 1 kHz

    5 %: 15 Hz to 750 Hz

    Buffered output: Acceleration, 100 mV/g

    Electrical

    Power (Two wire loop power):

    +22 to +36 Vdc

    Maximum load (see note maximum

    load resistance calculations for specific

    requirements): Up to 600 Ohms resistive

    Grounding: Case isolated

    Environmental

    Operating temperature: 20 to +80 C

    (-4 to +176 F)

    Sealed: Epoxy encapsulated

    Enclosure: SS, NEMA 4, 4X, 12

    Mounting: Stud mounted

    Weight (without display): 227 g (8 oz.)

    Regulatory approval

    CE Mark: SKF Loop-powered Vibration

    Transmitter CMSS 420VT and displays

    CMSS 420LCD and CMSS 420LED

    SKF Loop-powered VibrationTransmitters seriesCMSS 420VT

    20

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    21/40

    CMSS 420EL 90 Degree 3/4 by 3/4

    NPT Elbow

    Useful for connecting CMSS 420VT to

    hard or flexible conduit. When used

    with the CMSS 420WF, provides asimple weatherproof exit for the

    instrument wire.

    CMSS 203 Pipe Thread Accelerometer

    Mounting Adapter

    They are provided in several NPT sizes

    to accommodate the most common

    plugs found on most machinery. The

    adapters have a 1/4-28 threaded

    hole to mate with the CMSS 420VT

    and most common accelerometers

    and vibration transmitters.

    Part numberPipe thread mountingadapter

    CMSS 203-011/2 (NPT) National pipetapered thread

    CMSS 203-023/4 (NPT) National pipetapered thread

    CMSS 203-033/8 (NPT) National pipetapered thread

    CMSS 203-041/4 (NPT) National pipetapered thread

    Accessories

    CMSS 420LCD/CMSS 420LED Display

    Retrofit (requires transmitter).

    LCD displays actual vibration levels in

    velocity on a Liquid Crystal display.

    LED displays actual vibration levels invelocity on a Light Emitting Diode

    display. The displays are shipped loose,

    and it is a simple installation. Includes

    a BNC connector that provides access

    to the raw acceleration signal for the

    CMSS 420VT.

    CMSS 420BNC BNC Adapter Retrofit

    90 Degree 3/4 NPT conduit elbow

    with a BNC connector to access the raw

    acceleration signal. This is useful for

    connecting the CMSS 420VT to the

    portable data collectors.

    CMSS 420WF 3/4 NPT Weatherproof

    Cable Fitting

    When used with the CMSS 420EL,

    provides a simple weatherproof exit for

    the instrument wire.

    Ordering information

    CMSS 420VT-1, 25.4 mm/sec. (0-1 in/

    sec.) RMS, includes 1/4-28 and M8

    Mounting Studs

    CMSS 420VT-2, 50.8 mm/sec. (0-2 in/

    sec.) RMS, includes 1/4-28 and M8Mounting Studs

    Optional display

    Light Emitting Diode

    Display (LED)

    Liquid Crystal Display

    (LCD)

    CMSS 420LED-010-1 in/sec.

    CMSS 420LCD-010-1 in/sec.

    CMSS 420LED-020-2 in/sec.

    CMSS 420LCD-020-2 in/sec.

    CMSS 420LED-5125.4 mm/sec.

    CMSS 420LCD-5125.4 mm/sec.

    CMSS 420LED-5250.8 mm/sec.

    CMSS 420LCD-5250.8 mm/sec.

    NOTE: Maximum load resistance calculations: RLoad = (Vs - 13.5 - Vd) / 0.032

    Where: RLoad = Load Resistance Vs = DC Supply Voltage Vd = Display Voltage (5.0 Vdc for LED, 2.0 Vdcfor LCD, 0 Vdc if not using a display unit)

    For Example:Using a LED Display and a Supply Voltage of 24 VdcSupply Voltage Vs = 24 V; Display Voltage Vd = 5.0Vdc for LED RLoad = (Vs - 13.5 V - Vd) / 0.032 = (24 V - 13.5 V - 5 Vdc) / 0.032 = 172 Ohm

    SKF Loop-powered Vibration Transmitters series CMSS 420VT

    21

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    22/40

    Specifications

    Specifications conform to ISA-

    RP- 37.2 (1-64) and are typical

    values referenced at +24 C

    (+75 F), 24 Vdc supply, 4 mA

    constant current and 100 Hz.

    Dynamic

    Sensitivity: 100 mV/g

    Sensitivity precision: 5 % at

    +25 C (+77 F)

    Acceleration range: 80 g peak Amplitude linearity: 1 %, up

    to full scale

    Frequency range:

    5 %; 3.0 to 5 000 Hz

    10 %; 1.0 to 9 000 Hz

    3 dB; 0.5 to 14 000 Hz

    Resonance frequency:

    Mounted, nominal 30 kHz

    Transverse sensitivity: 5 % of

    axial

    Electrical

    Power requirements:Voltage source: +24 Vdc

    nominal, +18 to +30 Vdc

    Constant current diode:

    2 to 10 mA dc,

    recommended 4 mA

    Electrical noise: 2.0 Hz;

    20 g/Hz

    Output impedance: < 100

    Bias output voltage: 12 Vdc

    Grounding: Case isolated,

    internal shielding

    Environmental

    Temperature range: 50 to

    +120 C (58 to +248 F),

    operating temperature

    Vibration limits: 500 g peak

    Shock limit: 5 000 g peak

    Electromagnetic sensitivity,

    equivalent g, maximum:

    70 g/gauss

    Sealing: Hermetic

    Using detailed knowledge

    acquired from many years of

    supplying high quality sensors to

    a broad spectrum of industry

    users, SKF offers rugged

    accelerometers designed for the

    pulp and paper, petrochemical,

    steel, mining and construction,

    metal working, and machine

    tool industries.

    Features

    For use with the SKF Junction

    Boxes, On-line Systems,

    Protection Systems and the

    Portable Data Collection

    Instruments

    Rugged, economical, and all

    around general purpose

    sensor

    Sensitivity, 100 mV/g to

    optimize use in multiple

    applications

    Exceptional bias voltage (BV)

    stability at elevatedtemperatures

    Designed for exceptional low

    noise level for low elevated

    temperatures

    Meets stringent CE, EMC

    requirements

    Smaller profile industrial

    accelerometers

    Two (2) mounting studs

    (1/4-28 and M8 x 1.25)

    provided

    Corrosion resistant and hermetically sealed for

    humidity areas

    Reverse polarity wiring

    protection

    Base strain sensitivity:

    200 g/microstrain

    CE: According to the generic

    immunity standard for

    Industrial Environment

    EN50082-2.

    Acceptance Criteria: The

    generated false equivalent g

    level under the above test

    conditions should be less than

    2 milli g peak to peak.

    Physical

    Dimensions: See drawing

    Weight: 90 grams

    Case material: 316L stainless

    steel

    Mounting: Internal 1/4-28

    thread. Mounting studs

    provided. One (1) 1/4-28 to

    1/4-28 english thread and

    one (1) M8 x 1.25 metric

    thread.

    Mounting torque: 2,9 N-m(24 in-lbs)

    Connector:

    Pin A: Signal/Power

    Pin B: Common

    Mating connector:

    CMSS 3106F-10SL-4S or

    equivalent

    Recommended cable: Two

    conductor shielded, teflon

    jacket, 100 pF/m (30 pF/ft)

    Ordering information

    CMSS 2100 General purpose

    industrial accelerometer with

    top exit MIL-C-5015 two (2)

    pin connector.

    1/4-28 and M8 mounting

    studs provided. Calibration

    sensitivity and nominal

    sensitivity is provided for

    each accelerometer

    package.

    Diagrams

    MODEL CMSS2100

    S/N S00000

    A B

    53.0 mm(2.10)

    1/4-28MountingHole19.0 mm

    (0.75)

    Diameter

    22.3 mm(0.87)

    20.3 mm(0.80)

    7/8 Hex

    2-Pin ConnectorMIL-C-5015

    -20 0 +25 +50 +80 +120 (-4) (+32) (+77) (+122) (+176) (+248)

    Temperature C (F)

    Typical Temperature Response20

    10

    0

    -10

    -20

    De

    viation,

    %

    Sensitivity

    0.5 10 100 1 k 20 K

    Frequency, Hz

    Typical Frequency Response3

    2

    1

    0

    -1

    -2

    -3

    eviation,

    d

    CMSS 2100General purpose industrial accelerometer

    Incorporating the latest in technology to meet the demandingCE, EMC, and low noise level requirements.

    22

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    23/40

    Specifications

    Specifications conform to

    ISA-RP-37.2 (1-64) and are

    typical values referenced at

    +24 C (+75 F), 24 Vdc

    supply, 4 mA constant current

    and 100 Hz.

    Dynamic

    Sensitivity: 100 mV/g Sensitivity precision: 10 % at

    +25 C (+77 F)

    Acceleration range: 80 g peak

    Amplitude linearity: 1 %

    Frequency range:

    10 %; 1.0 to 5 000 Hz

    3 dB; 0.7 to 10 000 Hz

    Resonance frequency:

    Mounted, minimum 22 kHz

    Transverse sensitivity: 5 % of

    axial

    ElectricalPower requirements:

    Voltage source: +18 to

    +30 Vdc

    Constant current diode:

    2 to 10 mA dc,

    recommended 4 mA

    Electrical noise: 2.0 Hz;

    20 g/Hz

    Output impedance:

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    24/40

    Description

    CMSS 9100 is a single shielded, single

    twisted pair cable with the conductors

    individually insulated with Dupont FEP

    Teflon, a braided shield with drain wire and

    an outer insulated jacket also made of clear

    Dupont FEP Teflon. The cable is wrapped

    with a color tape under the outer insulated

    jacket and also has superimposed on the

    color tape a white marker tape with cable

    designation and SKF logo.

    CMSS 9200 is a double shielded, singletwisted pair cable with the conductors

    individually insulated with Dupont FEP

    Teflon, an inner shield of aluminum

    polyester foil with drain wire, an inner

    insulated jacket of Dupont FEP Teflon, a

    braided outer shield and the outer insulated

    jacket of clear Dupont FEP Teflon. The cable

    is wrapped with a color tape under the outer

    insulated jacket and also has superimposed

    on the color tape a white marker tape with

    cable designation and SKF logo.

    Recommended usesThe single shield cable is recommended for

    use with sensors in normal industrial

    applications where historically these type

    cables have been previously used and

    installed.

    The double shield cable is highly

    recommended for use with sensors in

    industrial installations where there is a high

    noise field with one such example being

    machine tools and another being power

    generating facilities.

    Specifications

    (applicable to both models)

    Conductors: Tin plated copper, 19 x 32

    strands, size 20 AWG (American Wire

    Gauge).

    Color code: Black and White pair, Cable

    color is yellow with white SKF label.

    Outer jacket diameter: 0.190 in.

    (0.005 in.), includes glass fillers for

    roundness.

    Wire materials: All conductors, drain wires

    and braided shields are of tin platedcopper.

    Capacitance: Approximately 89 pF/m

    (27 pF/ ft).

    Voltage rating: 600 V RMS.

    Working temperature range:

    80 to +200 C (112 to +392 F).

    Heat and flame resistance: Meets

    requirements of UL 910 Stiner Tunnel

    test.

    Single/Double Shield Twisted Pair CablesCMSS 9100/CMSS 9200

    SKFs CMSS 9100 and CMSS 9200 premium sensor cables provide superior performance indemanding environments.

    Ordering information

    CMSS 9100-500 500 foot spool (150

    meters) single shield with continuous

    cable length.

    CMSS 9100-1000 1,000 foot spool (300

    meters) single shield with continuous

    cable length.

    CMSS 9200-500 500 foot spool (150

    meters) double shield with continuous

    cable length.

    24

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    25/40

    Features

    Q-type connector

    IP 68 (submersible, one meter of water)High temperature +200 C (+392 F)

    Standard recommendation for harsh

    environments

    Features

    SL-type connector

    IP 66 (withstands direct water jet)

    Elevated temperature +150 C (+302 F)

    Premium connector

    SKF Cable Assembly IP 68CMSS R6Q(I)*-9100-XX

    Ordering information

    Available in two versions:

    I = Isolated type, for grounding on

    instrument side, or leave blank for

    grounding on machine side.

    -XX = 16, 32 or 64 for equivalent

    length in feet

    SKF Cable Assembly IP 66CMSS R6SL(I)*-9100-XXOrdering information

    Available in two versions:

    I = Isolated type, for grounding on

    instrument side, or leave blank for

    grounding on machine side.

    -XX = 16, 32 or 64 for equivalent

    length in feet

    25

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    26/40

    CMSS 260 series NEMA 4 and NEMA 4X Enclosures

    CMSS 265 series Termination Junction Boxes

    CMSS 300 series BNC Junction Boxes

    CMSS 310 series Switchable BNC Junction Boxes

    Industry standards

    (For all junction boxes and enclosures) and according to version (material).

    Rating Painted Steel Fiberglass Stainless Steel

    UL 50 Type 4, 12 and 13 N/AType 3R, 4, 4X

    and 12

    UL 508A, UL 508 Type 4, 12 and 13Type 3R, 4, 4X

    and 12Type 3R, 4, 4X

    and 12

    NEMA/EEMAC Type 4, 12 and 13Type 3R, 4, 4X

    and 12Type 3R, 4, 4X

    and 12

    JIC EGP-1-1967 EGP-1-1967 EGP-1-1967

    CSA Type 4 and 12 Type 4, 4X and 12 Type 4, 4X and 12

    IEC 60529 IP66 IP66 IP66

    CMSS 310 series Switchable BNC Junction Boxes

    CMSS 260 series NEMA 4 and NEMA 4X enclosures

    CMSS 265 series Termination Junction Boxes

    CMSS 300 series BNC Junction Boxes

    Junction Boxes and EnclosuresCMSS 260, CMSS 265, CMSS 300 and CMSS 310

    26

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    27/40

    CMSS 260PS NEMA 4 PaintedSteel Enclosures

    These enclosures are designed for use inareas that may be regularly hosed downor are very wet, and they are suitablefor indoor or outdoor installations.Wherever protection from dust, dirt, oil,

    or hose-directed water is essential.

    ANSI 61 powder coated on the interiorand exterior surfaces, constructed from14 gauge mild steel.

    Ordering information

    CMSS 260PS -XX

    NEMA 4 PaintedSteel Enclosures

    (dimensions -height x width x depth)

    -0115.2 cm x 15.2 cm x10.2 cm(6.0 x 6.0 x 4.0)

    -0220.3 cm x 15.2 cm x8.9 cm(8.0 x 6.0 x 3.5)

    -0325.4 cm x 20.3 cm x15.2 cm(10.0 x 8.0 x 6.0)

    CMSS 260FG NEMA 4XFiberglass Enclosures

    NEMA 4X Fiberglass Enclosures aredesigned for use in areas that may beregularly hosed down or are very wet,and they are suitable for indoor oroutdoor installations.

    The enclosure is used in highlycorrosive environments typically foundin oil refineries, chemical processingplants, waste-water treatment, marineinstallations, pulp and paper processing,and electroplating plants.

    Ordering information

    CMSS 260FG -XX

    NEMA 4X FiberglassEnclosures(dimensions -

    height x width x depth)

    -01 15.2 cm x 15.2 cm x10.2 cm(6.0 x 6.0 x 4.0)

    -0220.3 cm x 15.2 cm x8.9 cm(8.0 x 6.0 x 3.5)

    -0325.4 cm x 20.3 cm x15.2 cm(10.0 x 8.0 x 6.0)

    The enclosures covers have a continuous hinge on the long side of the unit for convenience, and are secured to the enclosure with clamps.The enclosures are available in NEMA 4 or NEMA 4X to cover most applications. All enclosures are provided with an oil resistant gasket and

    clamps for easy screwdriver access.

    CMSS 260SS NEMA 4XStainless Steel Enclosures

    Constructed from 14 gauge 304 stainlesssteel rather than a mild steel. They aredesigned for the same use as the NEMA4 enclosures with the ability to resistcorrosive environments.

    Ordering information

    CMSS 260SS -XX

    NEMA 4X StainlessSteel Enclosures

    (dimensions -height x width x depth)

    -0115.2 cm x 15.2 cm x10.2 cm(6.0 x 6.0 x 4.0)

    -0220.3 cm x 15.2 cm x8.9 cm(8.0 x 6.0 x 3.5)

    -0325.4 cm x 20.3 cm x15.2 cm

    (10.0 x 8.0 x 6.0)

    NEMA 4 and NEMA 4X EnclosuresCMSS 260 series

    NEMA 4 and NEMA 4X enclosures are provided by SKF for housing of any instrument.

    27

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    28/40

    The CMSS 265 series Termination Junction Boxes are multiple channel connectingcenters for terminating the outputs of accelerometers or other transducer field wiring.

    Crew clamp, DIN-rail mounted terminals (3 inputs per channel, usually signal, commonand shield) are provided for the intermediate termination of accelerometers, proximityprobes, speed sensors, RTDs, and other transducers.

    The CMSS 265 seriesJunction Boxes areavailable in three (3)versions:

    NEMA 4X Fiberglass(FG)

    NEMA 4 PowderCoated Steel (PS)

    NEMA 4X StainlessSteel (SS)

    CMSS 265FG NEMA 4XFiberglass Junction Boxes

    The CMSS 265FG NEMA 4X enclosuresare made of molded fiberglass polyesterand is easily punched or drilled. It hasoutstanding chemical and temperatureresistance and physical properties. A

    seamless foam in-place gasket assuresa watertight and dust tight seal. Screwcovers are secured with captivated monelcover screws.

    Ordering information

    CMSS 265FG -XXNEMA 4X Fiberglass

    Junction Box

    -022 channels,6 terminals

    -044 channels,12 terminals

    -08 8 channels,24 terminals

    -1212 channels,36 terminals

    -1616 channels,48 terminals

    CMSS 265SS NEMA 4XStainless Steel Junction Boxes

    The CMSS 265SS NEMA 4X enclosureis constructed from 14 gauge 304Stainless Steel. This enclosure will betterresist corrosive environments than theCMSS 265PS steel boxes. CMSS 265SS

    junction boxes feature continuouslywelded seems, ground smooth with noholes or knockouts. An oil-resistant,in-place gasket assures a watertight anddust tight seal. Stainless Steel screwsand clamps are provided.

    Ordering information

    CMSS 265SS -XXNEMA 4X 304Stainless SteelJunction Box

    -022 channels,6 terminals

    -044 channels,12 terminals

    -088 channels,24 terminals

    -1212 channels,36 terminals

    -1616 channels,48 terminals

    Dimensional information

    Description Dimensions(height x width x depth)

    2 channels,6 terminals

    15.2 cm x 15.2 cm x 10.2 cm(6.0 x 6.0 x 4.0)

    4 channels,12 terminals

    15.2 cm x 15.2 cm x 10.2 cm(6.0 x 6.0 x 4.0)

    8 channels,24 terminals

    20.3 cm x 15.2 cm x 10.2 cm(8.0 x 6.0 x 4.0)

    12 channels,36 terminals

    25.4 cm x 20.3 cm x 15.2 cm(10.0 x 8.0 x 6.0)

    16 channels,48 terminals

    35.6 cm x 30.5 cm x 20.3 cm(14.0 x 12.0 x 8.0)

    CMSS 265PS NEMA 4 PowderCoated Steel Junction Boxes

    The CMSS 265PS NEMA 4 enclosure isconstructed of 14 gauge mild steel andis ANSI 61 gray polyester powder coatedon the all surfaces. A seamless foamin-place gasket assures a watertight and

    dust tight seal.

    Ordering information

    CMSS 265PS -XXNEMA 4 Powder

    Coated SteelJunction Box

    -022 channels,6 terminals

    -044 channels,12 terminals

    -088 channels,24 terminals

    -12

    12 channels,

    36 terminals

    -1616 channels,48 terminals

    Termination Junction BoxesCMSS 265 series

    28

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    29/40

    Features

    Quick and convenient access to remotely installedaccelerometers with Portable Data Collector/Analyzer

    Withstands harsh factory and outdoorenvironments

    The CMSS 300 series BNC Junction Boxes aremultiple channel connecting centers for terminatingthe outputs of accelerometers or other transducerfield wiring. They are normally located in closeproximity to the machine to reduce wiring cost andprovide convenient access to the vibration signal bya portable data collector/analyzer.

    The CMSS 300 series Junction Boxes are availablein three (3) versions:

    NEMA 4X Fiberglass (FG)

    NEMA 4 Powder Coated Steel (PS)

    NEMA 4X Stainless Steel (SS)

    Both internal and external switch/BNC models areavailable. Internal models are provided with quickaccess latches and external models with screwcovers and protective caps for the BNC fitting. Inharsh environments internal models should bespecified. Black and white bezel tagging is providedfor channel and switch identification.

    CMSS 300FG NEMA 4X Fiberglass Junction Boxes

    The CMSS 300FG NEMA 4X Fiberglass enclosure is made of moldedfiberglass polyester and is easily punched or drilled. It has outstandingchemical and temperature resistance and physical properties.

    A seamless foam in-place gasket assures a watertight and dust tight seal.

    Screw covers are secured with captivated Monel cover screws.

    Ordering information

    CMSS 300FG -XX -XXNEMA 4X FiberglassBNC Junction Box

    Dimensions(height x width x depth)

    -01 1 Channel16.5 cm x 16.5 cm x 10.8 cm(6.50 x 6.50 x 4.25)

    -02 2 Channels16.5 cm x 16.5 cm x 10.8 cm(6.50 x 6.50 x 4.25)

    -04 4 Channels21.6 cm x 16.5 cm x 10.8 cm(8.50 x 6.50 x 4.25)

    -06 6 Channels21.6 cm x 16.5 cm x 10.8 cm(8.50 x 6.50 x 4.25)

    -01 Internal BNC

    -02 External BNC

    BNC Junction BoxesCMSS 300 series

    29

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    30/40

    CMSS 300PS NEMA 4 Powder Coated Steel Junction Boxes

    The CMSS 300PS Powder Coated Steel NEMA 4 enclosure is constructed of 14 gauge mild steel and is ANSI 61 gray polyesterpowder coated on the all surfaces.

    Ordering information

    CMSS 300PS -XX -XXNEMA 4 Powder CoatedSteel BNC Junction Box

    Dimensions(height x width x depth)

    -01 1 Channel 19.1 cm x 17.8 cm x 10.2 cm (7.50 x 7.00 x 4.00)

    -02 2 Channels 19.1 cm x 17.8 cm x 10.2 cm (7.50 x 7.00 x 4.00)

    -04 4 Channels 24.1 cm x 17.8 cm x 8.9 cm (9.50 x 7.00 x 3.50)

    -06 6 Channels 24.1 cm x 17.8 cm x 8.9 cm (9.50 x 7.00 x 3.50)

    -01 Internal BNC

    -02 External BNC

    CMSS 300SS NEMA 4X Stainless Steel Junction BoxesThe CMSS 300SS NEMA 4X Stainless Steel enclosure is constructed from 14 gauge 304 Stainless Steel.

    Ordering information

    CMSS 300SS -XX -XXNEMA 4X Stainless Steel

    BNC Junction BoxDimensions

    (height x width x depth)

    -01 1 Channel 19.1 cm x 12.7 cm x 10.2 cm (7.50 x 5.00 x 4.00)

    -02 2 Channels 19.1 cm x 12.7 cm x 10.2 cm (7.50 x 5.00 x 4.00)

    -04 4 Channels 24.1 cm x 17.8 cm x 10.2 cm (9.50 x 7.00 x 4.00)

    -06 6 Channels 24.1 cm x 17.8 cm x 10.2 cm (9.50 x 7.00 x 4.00)

    -01 Internal BNC

    -02 External BNC

    CMSS 300 series BNC Junction Boxes

    30

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    31/40

    Features

    The CMSS 310 series Switchable BNC JunctionBoxes are designed for terminating and switchingthe outputs of up to 48 accelerometers. Theyare installed in a location as close to the machineas practical to reduce wiring cost and yet provideconvenient safe access to the vibration signalby an operator with a portable data collector oranalyzer.

    The CMSS 310 series Switchable BNC JunctionBoxes are available in three (3) versions:

    NEMA 4X Fiberglass (FG)

    NEMA 4 Powder Coated Steel (PS)

    NEMA 4X Stainless Steel (SS)

    Both internal and external switch/BNC models areavailable. Internal models are provided with quickaccess latches and external models with screwcovers and protective caps for the BNC fitting.In harsh environments internal models shouldbe specified. Black and white bezel tagging isprovided for channel and switch identification.

    CMSS 310FG NEMA 4X Fiberglass Junction Boxes

    The CMSS 310FG NEMA 4X Fiberglass enclosure is made of molded fiberglasspolyester and is easily punched or drilled. It has outstanding chemical andtemperature resistance and physical properties.

    A seamless foam in-place gasket assures a watertight and dust tight seal.Screw covers are secured with captivated Monel cover screws.

    Ordering information

    CMSS 310FG -XX -XXNEMA 4X Fiberglass

    Switchable BNCJunction Box

    Dimensions(height x width x depth)

    -06 6 Channels24.1 cm x 17.8 cm x 8.9 cm(9.50 x 7.00 x 3.50)

    -12 12 Channels24.1 cm x 17.8 cm x 8.9 cm(9.50 x 7.00 x 3.50)

    -24 24 Channels39.4 cm x 33.0 cm x 15.2 cm(15.50 x 13.00 x 6.00)

    -32 32 Channels44.5 cm x 38.1 cm x 15.2 cm(17.50 x 15.00 x 6.00)

    -48 48 Channels44.5 cm x 38.1 cm x 15.2 cm(17.50 x 15.00 x 6.00)

    -01 Internal BNC

    -02 External BNC

    Switchable BNC Junction BoxesCMSS 310 series

    31

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    32/40

    CMSS 310PS NEMA 4 Powder Coated Steel Junction Boxes

    The CMSS 310PS NEMA 4 Powder Coated Steel enclosure is constructed of 14 gauge mild steel and is ANSI 61 gray polyesterpowder coated on the all surfaces.

    Ordering information

    CMSS 310PS -XX -XXNEMA 4 Powder CoatedSteel BNC Junction Box

    Dimensions(height x width x depth)

    -06 6 Channels 24.1 cm x 17.8 cm x 8.9 cm (9.50 x 7.00 x 3.50)

    -12 12 Channels 24.1 cm x 17.8 cm x 8.9 cm (9.50 x 7.00 x 3.50)

    -24 24 Channels 39.4 cm x 33.0 cm x 15.2 cm (15.50 x 13.00 x 6.00)

    -32 32 Channels 44.5 cm x 38.1 cm x 15.2 cm (17.50 x 15.00 x 6.00)

    -48 48 Channels 44.5 cm x 38.1 cm x 15.2 cm (17.50 x 15.00 x 6.00)

    -01 Internal BNC

    -02 External BNC

    CMSS 310SS NEMA 4X Stainless Steel Junction Boxes

    The CMSS 310SS NEMA 4X Stainless Steel enclosure is constructed from 14 gauge 304 Stainless Steel.

    Ordering information

    CMSS 310SS -XX -XXStainless Steel NEMA 4X

    BNC Junction BoxDimensions

    (height x width x depth)

    -06 6 Channels 24.1 cm x 17.8 cm x 10.2 cm (9.50 x 7.00 x 4.00)

    -12 12 Channels 24.1 cm x 17.8 cm x 10.2 cm (9.50 x 7.00 x 4.00)

    -24 24 Channels 39.4 cm x 33.0 cm x 15.2 cm (15.50 x 13.00 x 6.00)

    -32 32 Channels 44.5 cm x 38.1 cm x 15.2 cm (17.50 x 15.00 x 6.00)

    -48 48 Channels 44.5 cm x 38.1 cm x 15.2 cm (17.50 x 15.00 x 6.00)

    -01 Internal BNC

    -02 External BNC

    CMSS 261 Liquid Tight Strain Relief Connectors

    The CMSS 261 Liquid Tight Strain Relief Connectors are usedfor either extension cable or multi-conductor wire entriesinto the CMSS 310 BNC Junction boxes. Connectors areconstructed of Polyamide and provide both environmentalsealing and strain relief. The connectors are temperature ratedto -60 C to +100 C (-40 F to +212 F) and have a pressurerating of up to 150 PSIG. Check the cable data sheet for thediameter of your extension cable.

    Ordering information

    CMSS 261 -XXMinimum OuterCable Diameter

    Maximum OuterCable Diameter

    -01 2 mm (0.08) 5 mm (0.20)

    -02 4 mm (0.16) 8 mm (0.31)

    -03 5 mm (0.20) 9 mm (0.35)

    -04 7 mm (0.28) 12 mm (0.47)

    -05 9 mm (0.35) 18 mm (0.70)

    -06 13 mm (0.51) 20 mm (0.78)

    CMSS 310 series Switchable BNC Junction Boxes

    32

  • 7/21/2019 CM2355 SKF Condition Monitoring Essentials

    33/40

    parameter for judging rotational andstructural problems like imbalance,resonance, misalignment, looseness,and stress applied to components.

    Many machinery problems may causeexcessive overall vibration. Mechanicallooseness, imbalance, soft foundation,misalignment, rotor bow, resonance,eccentricity, bad belts, or lost rotorvanes can all be measured with overallISO (International Organization for

    Standardization) vibration measurements.

    Measuring the overall vibration of amachine or component, or the structure ofa machine, and comparing the measuredvalue to the machines normal value (or toISO 10816 standards) indicates machineryhealth and condition changes.

    NOTE: Overall vibration is not an indicator ofbearing or gear mesh problems thattypically occur in higher frequencyranges.

    Enveloped acceleration

    Bearing/gear mesh frequency vibration(10 kHz to 30 kHz)

    Enveloped acceleration measurementsmeasure the high frequency repetitivevibration signals typically caused bybearing and gear mesh problems.

    Envelope detection is very useful in rollingelement bearing and gear mesh analysiswhere a low amplitude, repetitive vibrationsignal may be hidden by the machinesrotational and structural vibration noise.

    For example, suppose a rolling elementbearing has a defect on its outer raceway.Each rolling element strikes the defectas it passes the defect, causing a small,repetitive vibration signal. This vibrationsignal is of such low amplitude that, undernormal ISO vibration monitoring, it islost in the machines other rotational andstructural noise.

    Envelope detection filters out lowfrequency rotational signals, then enhancesthe high frequency defect signals to focus

    Overview

    A multi-parameter approach to conditionmonitoring provides two different methodsfor monitoring machinery condition.This allows for early detection of specificmachinery problems and provides moreways to measure changes in machinerycondition.

    The SKF Vibration Penplusis a multi-parameter vibration monitoring tool

    capable of measuring vibration (causedby rotational and structural problemslike imbalance, misalignment, looseness,etc.), and capable of measuring vibrationin higher frequencies (caused by rollingelement bearing or gear mesh problems).

    Multi-parameter monitoring is themost thorough and effective methodfor monitoring bearing and machinerycondition. The Vibration Penplustoolsmulti-parameter approach providesaccurate and reliable data upon which tobase maintenance decisions and promotesearly detection, confirmation, and accurate

    trending of bearing and machineryproblems.

    Functional description

    When performing measurements, theVibration Penplustools sensor input signalis processed to produce two differentmeasurements for each machineryPOINT, Overall Vibration and envelopedacceleration.

    The Vibration Penplustools LCDsimultaneously displays both measurement

    values. Depending on the type andlocation of the machinery componentbeing measured, either or both readingsmay be of interest.

    Overall vibration

    (ISO* 10816, Part 1-6) Low frequencyvibration (10 Hz to 1 kHz)

    Overall velocity vibration occurring inthe 10 Hz to 1 kHz frequency band isconsidered the best operating

    on repetitive events in the 10 kHz to30 kHz frequency range, and provides an

    averaged peak value for early detection ofbearing and gear mesh problems.NOTE: Enveloped acceleration measurements

    do not detect rotational or structuralvibration caused by imbalance,misalignment, looseness, etc.

    Easy operation

    Vibration Penplusreadings are easilyperformed, simply:

    Turn the Vibration Pen pluson.Press the Vibration Pen plustoolssensor tip against your machinery

    measurement POINT.Wait for the readings to stabilize, andrecord the measurement values.

    Easy evaluation

    The Vibration Penplustools front-panelLCD simultaneously shows overall velocityvibration readings in mm/s RMS (CMVP50) or in in/s equivalent Peak (CMVP 40),and acceleration enveloping readings in gE(E indicating enveloped acceleration).

    The SKF Vibration Penplusseveritycard provides quick reference for