CMD 800 SeriesMODULAR SYSTEMS

Integral solutions for Clinical Chemistry

Page 2: CMD 800 Series

CMD 800X2 / CMD 800iX2

» Throughput: 1600/2000/2400 test/hour

» 580 samples on-board

» Reagent tray: 240 positions + ISE

» Reaction tray: 330 positions

CMD 800 / CMD 800i

» Throughput: 800/1200 test/hour

» 140 samples on-board

» Reagent tray: 120 positions + ISE

» Reaction tray: 165 positions

CMD 800X1 / CMD 800iX1

» Throughput: 800/1200 test/hour

» 440 samples on-board

» Reagent tray: 120 positions + ISE

» Reaction tray: 165 positions

CMD 800 SeriesMODULAR SYSTEMS

Page 3: CMD 800 Series

Large capacity140 slots on the sam-ple disk with 300 addi-tional sample slots on the “Sample Delivery Module” (SDM). 68 rea-

gents on-board + ISE and 165 glass cuvettes that increase its autonomy and advantages.Routine sample processing, automatic rerun and STAT.

Precise

High precision in aspiration15-300µL reagent aspiration with 0.5µL steps.1.5-35 µL sample aspiration with 0.1µL steps.

Cost-effective

Innovative

Coaxial disk for reagentsIndependent rotatory coaxial disks allow for continuous loading of reagents.

PhotometricsystemSpot light source tech-nology: two diaphragms and two lenses minimize the minimum reaction

volume (100 µL). The detector is formed by a 12-photodiode arrangement.

Water quality monitoringIt analyses and moni-tors deionized water quality via resistance principle reducing to

the minimum the possibility of accidentally using contaminated water.

Safe

A n t i - c o l l i s i o n protectionVertical and horizontal anti-collision protec-tion for sample and re-agent probes.

Clots and bubbles detectionThe clots and bubbles detection allows the identification of any ob-struction ensuring the correct aspiration of the sample.

Covered sam-pling systemDisk sampling allows working with the de-vice closed ensuring biosafety for the op-erator and creating a

silent work environment. Continuous load-ing of sample is allowed by its partial open-ing.

Low reagent con-sumptionThe low volume re-quired for reaction (100µL) reduces the re-agent consumption

costs. The exclusive design of the reagent bot-tles minimizes the residual volume.

Dedicated reagentsWide range of clini-cal chemistry and turbidimetric tests available in dedicat-

ed bottles with bar codes.

ISE: indirect po-tentiometry Lower reagent con-sumption and higher throughput in ISE measuring. Low cost

determinations are backed by the long lifes-pan of the electrodes: 30,000 tests/electrode.

User-friendly and intuitive softwareEasy learning and intui-tive software. Multilin-gual. Profile managing and graphic display of

all reaction points. Bi-directional connection.

Page 4: CMD 800 Series

CMD 800 SeriesMODULAR SYSTEMS

Technical Specifications

Throughput: CMD 800 / CMD 800i: from 800 tests/h to 1200 test/h CMD 800 X1 / CMD 800i X1: from 800 tests/h to 1200 test/h CMD 800 X2 / CMD 800i X2: from 1600 tests/h to 2400 test/h Sample handling Sample tray: 140 positions, including 25 cooled positions for calibrators and controls.SDM: Capacity for 300 samples.Sample volume: 1.5 µL – 35 µL, with 0.1 µL stepsSample probe: Liquid level and clot detection and collision protection. Reagent handling Reagent tray: 120 positions in coaxial disksReagent volume: 15-300 µL, with 0.5 µLReagent probe: Liquid level and clot detection and collision protection Bar code reader Bar code system Codebar, ITF (Interleaved two of five), code 128, code 39, code 93, and UPC/EAN. Bi-directional connection via LIS. Reaction system Reaction volume: 100-360 µLOperating temperature: 37°C with 0.1°C fluctuation Light source: Halogen tungstene lamp, 12V/20WSpot light source technology: Two diaphragms and two lenses minimize the minimum reaction volume (100 µL).Diffraction grating: Light dispersion Detector: 12-photodiode arrangementWavelength: 340nm, 380nm, 412nm, 450nm, 505nm, 546nm, 570nm, 605nm, 660nm, 700nm, 740nm, 800nmAbsorbance range: 0 – 3.4 Abs Electrolytes module Principle: Indirect potentiometry. Minimum sample volume: 22 µLIon Selective Electrode: Na+, K+, Cl-

Sample: Serum, plasma and urine. Calibration and control Calibration mode: Linear (one-point, two-point and multi-point), logit-log 4p, logit-log 5p, spline, exponential, polynomial, parabola.Quality control data management: Westgard rules, Levey – Jenning graphics, Twin plot. Operation unit Operating system: Windows® XP Professional/Home SP2 or Windows® Vista Home/Business Dimensions Analytical unit: 1600 mm (length) x 1015 (width) x 1200 (depth)Sample Delivery Module (SDM): 705 (length) x 1015 (width) x 920 (depth) Weight Analytical unit: 450 KgSample Delivery Module (SDM): 150 Kg