cme guidance 20140904 v1
TRANSCRIPT
![Page 1: CME Guidance 20140904 v1](https://reader038.vdocuments.net/reader038/viewer/2022102322/5883164f1a28ab31068b6495/html5/thumbnails/1.jpg)
User Guidance HUAWEICME
RAN Consultant:Ray Khastur‐20140904
![Page 2: CME Guidance 20140904 v1](https://reader038.vdocuments.net/reader038/viewer/2022102322/5883164f1a28ab31068b6495/html5/thumbnails/2.jpg)
Brief Information about CME
HUAWEI M2000 OMC Client can support exporting all parameter on MML Backup into EXCELSHEET, and also can be use to change the parameter directly from the EXCELSHEET and upload to M2000 after we change some parameter from consistency check of optimization part.In this occasion the guidance will tell you how to export the parameter.
Note: The excel contain Macro with default value of parameter that match with MML Command require.Only ON AIR Site can be export the data
![Page 3: CME Guidance 20140904 v1](https://reader038.vdocuments.net/reader038/viewer/2022102322/5883164f1a28ab31068b6495/html5/thumbnails/3.jpg)
1.Home Page
![Page 4: CME Guidance 20140904 v1](https://reader038.vdocuments.net/reader038/viewer/2022102322/5883164f1a28ab31068b6495/html5/thumbnails/4.jpg)
2.Create New Project (One Time Execution)
Once time you have already create a project, the value of parameter will always based on that date.For example:When you query all parameter at 4 Sept 2014 09:00, then there are some parameter changing at 10:00. When you query again with the same project, CME will export same result at 09:00 morning.
![Page 5: CME Guidance 20140904 v1](https://reader038.vdocuments.net/reader038/viewer/2022102322/5883164f1a28ab31068b6495/html5/thumbnails/5.jpg)
2. Fill Project Name and Site Selection
Fill Project Name
Set as Admin Set as Private
Select Site and Move to Right Column
![Page 6: CME Guidance 20140904 v1](https://reader038.vdocuments.net/reader038/viewer/2022102322/5883164f1a28ab31068b6495/html5/thumbnails/6.jpg)
2. Fill Project Name and Site Selection (Cont’d)
Fill Project Name
Set as Admin Set as Private
Select Site and Move to Right Column
Click OK
![Page 7: CME Guidance 20140904 v1](https://reader038.vdocuments.net/reader038/viewer/2022102322/5883164f1a28ab31068b6495/html5/thumbnails/7.jpg)
3.Project Page
![Page 8: CME Guidance 20140904 v1](https://reader038.vdocuments.net/reader038/viewer/2022102322/5883164f1a28ab31068b6495/html5/thumbnails/8.jpg)
3.Exporting Hardware & RF Parameter
![Page 9: CME Guidance 20140904 v1](https://reader038.vdocuments.net/reader038/viewer/2022102322/5883164f1a28ab31068b6495/html5/thumbnails/9.jpg)
3.Exporting Hardware & RF Parameter (Cont’d)
Chose BTS Version with properlyWith scenario:eNB Bulk Config
Next if done select the site
![Page 10: CME Guidance 20140904 v1](https://reader038.vdocuments.net/reader038/viewer/2022102322/5883164f1a28ab31068b6495/html5/thumbnails/10.jpg)
3.Exporting Hardware & RF Parameter (Cont’d)
We have to chose “Custom MOC”
Next if done select the site
![Page 11: CME Guidance 20140904 v1](https://reader038.vdocuments.net/reader038/viewer/2022102322/5883164f1a28ab31068b6495/html5/thumbnails/11.jpg)
3.Exporting Hardware & RF Parameter (Cont’d)
We have to chose “Custom MOC”
Select destination of Excelsheet write the file, click Next if Done
Chose which parameter you required to collect
![Page 12: CME Guidance 20140904 v1](https://reader038.vdocuments.net/reader038/viewer/2022102322/5883164f1a28ab31068b6495/html5/thumbnails/12.jpg)
4.Collecting and Exporting Parameter
![Page 13: CME Guidance 20140904 v1](https://reader038.vdocuments.net/reader038/viewer/2022102322/5883164f1a28ab31068b6495/html5/thumbnails/13.jpg)
5.Excelsheet ready to be open (attached)
F:\Work\PIWorks\nesia\Feature Test
Double click to open the file
![Page 14: CME Guidance 20140904 v1](https://reader038.vdocuments.net/reader038/viewer/2022102322/5883164f1a28ab31068b6495/html5/thumbnails/14.jpg)
THANK YOU