The Cutting Extinguisher
MASTConfex Sept 11, 2012, Anders Trewe
![Page 2: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/2.jpg)
More bang for buck!
Pooling and SharingSmart defenceSocietal changes in terms of Safety & SecurityUnorthodox situations and missionsLess fundsImplies longer life spans of vessels, less crew, more capabilities
Mitigation of austerity = mitigation of backdraft?
![Page 3: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/3.jpg)
1 liter of water
Traditional firefighting
![Page 4: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/4.jpg)
1 liter of water
Ultra high pressure water firefighting
![Page 5: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/5.jpg)
coldcut™ cobra concept
Safer FirefightingEfficient & Effective Shipboard FirefightingSaving Environment & Minimizing Collateral Damages
![Page 6: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/6.jpg)
Unique concept
Cuts through virtually any material Suppresses, cools and extinguishes fires from safe position outside of fire roomMobile, high pressure water mist with minimal use of waterThe only method with combined capabilities (penetrating, extinguishing, mobile, minimum of water)
![Page 7: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/7.jpg)
Tech specs - Five main parts
1. High pressure water pump
2. Abrasive vessel3. Hose reel with
high pressure hose
4. Hand lance5. Control system
31
4 2
![Page 8: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/8.jpg)
Key performance - Technology
![Page 9: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/9.jpg)
Typical Cobra Performance
0
100
200
300
400
500
600
700
800
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Tem
pera
ture
CUsing ultra high pressure on
4 MW fire in 20 foot container, penetration at t=12 min
Temperature
Time (min)
![Page 10: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/10.jpg)
Typical Cobra Performance
Penetration3 mm mild steel, 3-4 sec10mm mild steel, 30-40 sec8 mm LWC, <10 sec
CuttingMan hole in 60 mm LWC (400mm x 600m), < 6 min (with cutting frame)
![Page 11: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/11.jpg)
Cutting extinguisher features –in summary
Very efficient and effective on contained as well as ventilated firesFaster start of interventionSafe interventionMinimal water usage – no stability issuesSupports safe reclaim of compartmentNo toxic extinguishing mediaUnlimited extinguishing mediaRedundancy, complement and fall-backEasy to practice on board
![Page 12: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/12.jpg)
Shipboard Fires
![Page 13: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/13.jpg)
Shipboard Fires
hrs
![Page 14: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/14.jpg)
Shipboard Fires
(Örlogsboken, Försvarsmakten, 2003)
![Page 15: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/15.jpg)
Light Weight Composite StructuresVisby Class Stealth Corvettes
Photo: Kockums
![Page 16: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/16.jpg)
The Thermos Effect
![Page 17: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/17.jpg)
Light Weight Composite Structures
Problems “Thermos effect” - Containing fire not an option
Boundary cooling not feasible - Must fight fire in the compartment
How to handle breeched fixed installed fifi systems?
Low classified fire zones? Concealed areas?
BA-attacks adding oxygen, high risk procedure for crew and ship
Solution Cutting extinguisher as standard procedure and for redundancy
Safe position – outside of the fire zone
Fast deployment and boundary cooling from inside of thermos
Mitigates back draught
Buys time for BA to muster
In addition; less water = less stability issues, clearing tool for evac
![Page 18: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/18.jpg)
C330H Naval Kit
Photo: SAAB/Cold Cut Systems
![Page 19: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/19.jpg)
Emerging Arenas – Atalanta Operation
Photo: Lt Anna Norén/Försvarsmakten/Combat Camera.
![Page 20: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/20.jpg)
Emerging Arenas - Atalanta OperationCostal Corvettes HMS Malmö and HMS Stockholm
2008Oct, Formal RequestDec, Gov. decision2009Feb – Seaworthiness InspectionApr– Sea Lift Ships, SEMay 5th 2009, Arrival DjiboutiMay 9th 2009, On Patrol
![Page 21: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/21.jpg)
Emerging Arenas – Atalanta Operation
Problem Swedish Costal Corvettes on open sea mission
Low or none fire zone classification
Neither time, nor funds for retrofitting standard solutions
Solution Cutting extinguisher deemed as equivalent to A-60 fire
zone
Naval adapted specs of the cutting extinguisher
CCS developped the C330D Marine Unit in close cooperation with Royal Swedish Navy in 4 months
![Page 22: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/22.jpg)
C330D Marine Unit
![Page 23: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/23.jpg)
Enhanced Swedish Navy FiFi Tactics - SOP
Step Measure Tactic Time Personnel required
0. Preventive Fixed systems, insulation,training, awareness, etc.
1. Early detection
Assessment of situation, fire alarm
Immediate 1
2. First Attack,Containment
Portable extinguisher, seal fire zone, I report to XO
Immediate after 1. 1
3. Second Attack,Cobra attack
Break fire development.Boundary cooling from inside at CAPs (S) and fixed systems. Creating time for BA-attack
Immediate after 2. 2
4. BA-attack Safe re-entry procedure, extinguish fire. Cobra attack crew supports BA crew
Effect of 3 in fire zone, & BA crew mustered
2+3
![Page 24: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/24.jpg)
Solution to many issues – Swedish Navy
Efficient intervention from a safe position
1-2 min. Cobra attack makes dramatic effect on the fire development
Intervention without ventilating or entering into the fire zone
Boundary cooling from inside the “thermos”
Requires 2-3 crew and can be introduced prior BA attack muster
Safer environment for the BA-attack and re-entry procedures
Mitigates back draught / flash over
Less water used; less stability issues, less collateral damage
Excellent system for redundancy for breached fixed installed systems
Excellent for out of reach areas; voids, cofferdams and containers
Easy to introduce to present fifi procedures, easy to learn and practice
Less impact on the mission as a whole
Cost efficient solution for retrofitting enhanced fire protection
Can be used as a clearing tool, especially on composite vessels
![Page 25: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/25.jpg)
Cobra Navy Specs - C330D, C330H
High IP classification, mostly IP65Stainless brass and/or anti corrosion treatedHigh impact shock tested (+70 g, z-axis)Wire commanded hand lance (no radio)Hydraulic or Diesel poweredSwedish Navy and Nato NSN classification (C330D)Foam pump for Class A foamCBRN nozzleActive and passive freeze protectionAuxiliary submersible feed pump EMP, EMC, non-magnetic available on request
![Page 26: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/26.jpg)
Working standards
ISO 9001 certified since 2006ISO 14001 certified since 2006Referring standards: Machine Directive, EN 2006/42 EC
Machine safety; risk reduction, EN 12100:2010
Hydraulics fluid power, EN 4413:2010
EN 1846-3 “Permanently installed equipment for fire fighting and rescue service vehicles”
NSC and RMS 2010 (Reglemente för Militär Sjöfart)
and others
![Page 27: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/27.jpg)
Documentation – ILS, LCA
Instruction manualsQuick guidesRepair manualsSpare part cataloguesSystems safetyRecycle manualsMaintenance programsInstallation manualsE-learning programsTrainingCold Cut Systems holds ISO 9001 & 14001 certifications
![Page 28: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/28.jpg)
coldcutTM cutting frame
The coldcut™ cutting frame cuts open cargo bodies on ships, airplanes etc. in emergency situations
![Page 29: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/29.jpg)
coldcutTM pipe cutter
The coldcut™ pipe cutter can be used in areas where there is a risk for explosion, such as gas and fuel pipes
Driven by hydraulics and the head nozzle runs along two chains mounted to the pipe
![Page 30: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/30.jpg)
coldcutTM cold tap
The coldcut™ cold tap is used in both emergency situations and in preventive operations
Opens a hole in cisterns or tanks and offers a safe drainage solution of its contents (gas or fluid)
![Page 31: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/31.jpg)
Royal Swedish NavyCooperation in tactics and training
Shipboard FiFistrategy in combination with BATactics for Composite
Steel
Navy Sea Safety School, KarlskronaAdvanced Distributed Learning – E-learning
![Page 32: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/32.jpg)
Cold Cut Systems’ owners
SAAB Group
Metallica (Trade Union’s Venture Capital Firm)
Private Venture Capital Firm (Risk management)
Employees
Founder
![Page 33: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/33.jpg)
COLD CUT SYSTEMS
Peter Oom CEO, Sales Manager
David Nielsen Sales
Jimmy Otter Sales
Johan Biörsmark Cold Cut Academy Manager
Torwald Snickars Business Development
Mark Smitherman Sales & Business developer, UK
Patrik Söderberg Operations & R&D Manager
Tina Tandrup Controller
Anders Trewe Navy Sales & Business Projects Manager
![Page 34: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/34.jpg)
Some 500 units world wide
Navy -Shipping
Swedish Navy
Havariekommando
Salvage
Rescue
Scandinavia
Sweden
Norway
Denmark
Finland
Europe
U.K.
Germany
Netherlands
France
Asia
Malaysia
China
Taiwan
India
and more…
![Page 35: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/35.jpg)
Live Fire Demonstation at MAST
Tue. 11/9 17.00Wed 12/9 17.00150 m from Venue Entrance
![Page 36: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/36.jpg)
www.coldcutsystems.com
Thank you for your time!Anders Trewe, Cold Cut Systems
![Page 37: Cobra Cutting Extinguisher at MAST Confex 2012](https://reader034.vdocuments.net/reader034/viewer/2022042602/558c1ea6d8b42ac7528b4787/html5/thumbnails/37.jpg)
Cobra on other markets