Page 1: Column Design - As Per BS Code

Column design as Per BS 8110-1:1997

PHK/JSN

Page 2: Column Design - As Per BS Code

Contents :-

General Recommendations of the code Classification of columns Effective Length of columns & Minimum

eccentricity Design Moments in Columns Design

Page 3: Column Design - As Per BS Code

General Reco’s of the code

m for concrete 1.5, for steel 1.05 Concrete strength – CUBE STRENGTH Grades of steel Fe250 & Fe460 Primary Load combination 1.4DL+1.6LL E of concrete Ec = 5.5√fcu/ m 10% less than IS

Ultimate stress in concrete 0.67fcu/ m

Steel Stress-strain curve – Bilinear E of steel 200 kN/mm2

Page 4: Column Design - As Per BS Code

Classification of columns

SHORT – both lex/h and ley/b < 15 for braced columns

< 10 for unbraced columns

BRACED - If lateral stability to structure as a whole is provided by walls or bracing designed to resist all lateral forces in that plane.

else – SLENDER

Cl.3.8.1.5else – UNBRACED

Page 5: Column Design - As Per BS Code

Effective length &minimum eccentricityEffective length le = ßlo ß – depends on end condition at top and bottom of column.

emin = 0.05 x dimension of column in the plane of bending ≤ 20 mm

Page 6: Column Design - As Per BS Code

Deflection induced moments in Slender columns

Madd = N au where au = ßaKh

ßa = (1/2000)(le/b’)2

K = (Nuz – N)/(Nuz – Nbal) ≤ 1

Nuz = 0.45fcuAc+0.95fyAsc

Nbal = 0.25fcubd

Value of K found iteratively

Contd..

Page 7: Column Design - As Per BS Code

Contd..

Design Moments in Braced columns :-

Maximum Design Column Moment Greatest of

a) M2

b) Mi+Madd Mi = 0.4M1+0.6M2

c)M1+Madd/2

d) eminN

Columns where le/h exceeds 20 and only Uniaxially bent Shall be designed as biaxially bent with zero initial moment along other axis.

Page 8: Column Design - As Per BS Code

Braced and unbraced columns

Page 9: Column Design - As Per BS Code
Page 10: Column Design - As Per BS Code

Design Moments in UnBraced columns :-

The additional Moment may be assumed to occur at whichever

end of column has stiffer joint. This stiffer joint may be the

critical section for that column.

Deflection of all UnBraced columns in a storey

auav for all stories = Σ au/n

Page 11: Column Design - As Per BS Code
Page 12: Column Design - As Per BS Code

Design Moments in Columns

Axial Strength of column N = 0.4fcuAc + 0.8 Ascfy

Biaxial Bending Increased uniaxial moment about one axis

Mx/h’≥ My/b’ Mx’ = Mx + ß1 h’/b’My

Mx/h’≤ My/b’ My’ = My + ß1 b’/h’Mx

Where ß1 = 1- N/6bhfcu (Check explanatory hand book)

Minimum Pt =0.4% Max Pt = 6%

Page 13: Column Design - As Per BS Code

Shear in Columns

Shear strength vc’ = vc+0.6NVh/AcM

To avoid shear cracks, vc’ = vc√(1+N/(Acvc)

If v > vc’, Provide shear reinforcement

If v ≤ 0.8√fcu or 5 N/mm²

Page 14: Column Design - As Per BS Code

Design – Construction of Interaction Curve

A1

A2

Section Stress Strain

Distribution of stress and strain on a Column-Section

d1

d h0.5h

f1

f2

MN x

0.9x

1

2

0.67fcu/m 0.0035

Page 15: Column Design - As Per BS Code

Equilibrium equation from above stress block

N = 0.402fcubx + f1A1 +f2A2

M =0.402fcubx(0.5h-0.45x)+f1A1(0.5h-d1)+f2A2(0.5h-d)

f1 and f2 in terms of E and f1 = 700(x-d+h)/x

f2 = 700(x-d)/x

The solution of above equation requires trial and error method

Page 16: Column Design - As Per BS Code

THANK YOU