Come to the experts for your fumigation gas detection needs. Largest manufacturer of gas detection equipment in India An ISO 9001:2008 cer tified company DSIR National Award winner for indigenous technology development Uniphos Fumigation products are used in over 40 countries www.automat.com.ar [email protected] Dr. R. Bielsa 175 (ex Morlote) C1427AZA Buenos Aires, Argentina. Tel.: (54111) 4555-0055 / Fax: (5411) 4555-0044

Upload: others

Post on 15-Jan-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

Come to the experts for your fumigation gas detection needs.

UNIPHOS FUMIGATION EQUIPMENT

� Largest manufacturer of gas detection equipment in India

� An ISO 9001:2008 certi�ed company� DSIR National Award winner for indigenous

technology development� Uniphos Fumigation products are used in over

40 countries

www.automat.com.ar [email protected]. R. Bielsa 175 (ex Morlote) C1427AZA Buenos Aires, Argentina. Tel.: (54111) 4555-0055 / Fax: (5411) 4555-0044

Features

UNIPHOSGas Detector Tubes

PH3

� Ranges: 0.05 - 2.5 ppm0.1 - 10 ppm 50-1000 ppm 150-3000 ppm300-8000 ppm

� Simple to use and accurate

They are paper strips impregnated with sensing chemicals by a special process to detect PH . The strip on exposure to PH gas 3 3

changes its colour. The time it takes to change the colour is related to the PH gas 3

concentration. They are used for checking the fumigated area after aeration and to see if the area is safe for entry. These strips can also be given to the workers as badges when they are working in/near fumigated stacks.

UNIPHOSPH Detector Strips3

� Range: 0.3 – 10 ppm� The simple and cost e�ective method of

detection

Uniphos Dosimeter tubes present a unique method to determine the PH concentration 3

time product (DOSE). It is an ideal method to determine the adequacy of fumigation. The total dose is measured by exposing the dosimeter tube during the entire period of fumigation.

UNIPHOSPH Dosimeter Tubes3

Features3� Ranges : (1-20) X 10 ppm hrs

3: (1-200) X 10 ppm hrs� No sample draw pump required to

determine TWA concentration during fumigation period

Features

UNIPHOSFumisense Pro PH -Hi3

with inbuilt pump

UNIPHOS Fumisense Pro PH -Hi (CO)3

with inbuilt pump

� Range: 0 - 2000 ppm� Resolution: 1 ppm� Backlit LCD display Inbuilt air sampling

pump, with 30m sample draw capacity� Data logging facility with date / time /

gas concentration

� Speci�cally made for Tobacco fumigations� No sensitivity to even high concentrations

of CO (CO is generated by tobacco bales during storage)

Features� Range: 0 - 1000 ppm� Resolution: 1 ppm In-built air sampling

pump with 30m sample draw capacity� Data logging facility

For the detection of PH gas in the low TLV 3

(0.1/0.3 ppm) levels

Features� Range: 0 - 20 ppm� Resolution: 0.01 ppm� Easy to read OLED display

UNIPHOS350M-Phosphine Alert PH Lo Gas Monitor3

Features

PH 3PH 3 PHOSPHINE

Application� for the monitoring of PH concentrations 3

in the range of 200 - 2000 ppm inside the fumigated space

� for assuring that minimum required PH 3

concentration is maintained for entire fumigation period

Application

Application� TLV level monitoring around the

fumigated space� Leak detection from the fumigation

chamber

Application� For the spot checking of in and

around fumigated space� PH detection in safety range of 0.1/0.3 3

ppm and fumigation monitoring range of 200 - 2000 ppm

PH3

www.automat.com.ar [email protected]. R. Bielsa 175 (ex Morlote) C1427AZA Buenos Aires, Argentina. Tel.: (54111) 4555-0055 / Fax: (5411) 4555-0044

� For the detection of MBr gas in the safety level of 5 ppm. Used to protect workers during the fumigation operation, as well as to detect leaks from the fumigated chamber.

Features

UNIPHOS351M MBr-Lo Gas Monitor

� Range: 0 – 200 ppm� Resolution: 1 ppm� Backlit OLED display� Data logging facility

MBrMBr

UNIPHOSFumisense Pro MBr-(Lo/Hi)with inbuilt pump� For the detection/monitoring of Mbr

concentrations within the fumigated chamber. Based on either detection or monitoring, two models are available 'Fumisense Pro MBr-Lo or Fumisense Pro-Hi'

� MBr-Lo (0-200 ppm) for TLV (5 ppm) detection

� MBr-Hi (0-200 g/m3) for fumigation monitoring requirements

� Resolution: 1 ppm/ 1 mg/L� Inbuilt sample-draw pump� Data logging capability with date / time /

gas concentration

Features

� Ranges: 1-18 ppm10-100 ppm 50-1000 ppm

� Simple to use and accurate

Features

UNIPHOSMBr Gas Detector Tubes

KWIK DRAW UNIPHOS

Gas Detector tubes to spot-test the Phosphine concentrations in and around the fumigated area. With the lowest detection limit of 0.05 ppm, it becomes an ideal Phosphine Detection system. To be used along with the Kwik-Draw pumps for reliable sampling.

Features

KwikDrawPH Gas Detection Tubes3

� Ranges: 0.05 - 3 ppm0.1 - 100 ppm 50-2000 ppm

Short term Gas Detector tubes for the measurement of Mbr concentration in the range of 2-100 ppm and 200-8000 ppm.To be used along with the Kwik-Draw pumps for reliable sampling

Features

KwikDrawMBr Gas Detection Tubes

� Ranges: 2 - 100 ppm200-8000 ppm

Methyl Bromide

KwikDraw Gas Detector Tubes

� For spot checking of MBr in and around the fumigated space

� To be used with the ASP-40 Air Sampling Pump

Application

www.automat.com.ar [email protected]. R. Bielsa 175 (ex Morlote) C1427AZA Buenos Aires, Argentina. Tel.: (54111) 4555-0055 / Fax: (5411) 4555-0044

SO F2 2SO F2 2 SULPHURYL FLOURIDE

The Uniphos Fumi Spec-Lo is a battery operated portable instrument which can measure SO F in the range 0-100ppm. It has a specially 2 2

designed long path gas cell meant for the detection of low concentration of SO F in the range of 0-100 ppm. The sample for 2 2

measurement is drawn by the inbuilt sample draw pump. The instrument is suitable for applications related to personal protection and safety and also for leak detection when used with a sampling probe.

UNIPHOSFumispec - Lo

The Uniphos Fumispec-Hi is a fully automatic system specially designed for monitoring gas concentrations in a fumigation enclosure or silo and

3can measure SO F in the range 5-150 g/m . The basic components of 2 2

the instrument are the NDIR cell, a dust filter, dehumidifier, a sample draw pump, a set of solenoid valves and microprocessor based signal conditioning electronics.

UNIPHOSFumispec - Hi

UNIPHOSFumisense Dual Gas Monitor(PH and MBr)3

The UNIPHOS FUMISENSE is a microprocessor based Dual-Gas monitor for �eld determination of fumigation concentrations of “Phosphine and Methyl Bromide”. The FumiSense is an accurate and durable instrument developed speci�cally for fumigation monitoring. No single instrument can measure the fumigants at both parts per million-level and percentage level required for di�erent applications.

DUAL GAS MONITORPH & MBr3PH & MBr3

Features�

Ranges: PH : 0 - 2000 ppm (Electrochemical sensor)33MBr : 0 - 200 g/m (Thermal Conductivity Detector)

Individual pumps and gas paths for PH & MBr3

Advanced Microprocessor based instrument

Portable printer option for on-the-spot report printing

www.automat.com.ar [email protected]. R. Bielsa 175 (ex Morlote) C1427AZA Buenos Aires, Argentina. Tel.: (54111) 4555-0055 / Fax: (5411) 4555-0044

AutomaticFOUR ZONE GAS MONITOR

Features

UNIPHOS FUMITRACKAutomatic 4 Zone Fumigation Gas Monitor

� For high range monitoring of fumigation concentrations of PH / MBr 3

� Ranges: PH :0 - 2000 ppm3

or MBr: 0-200 g/m3

� Advanced micro-processor based technology� Easy to program and use� Suction pump – 100 meter suction capacity� Housed in a tough Pelican Storm Case – weather and water-proof� Inbuilt memory data storage capacity of 1000+ data values� Bluetooth and GSM connectivity options

For automatic periodic monitoring of fumigant gas concentrations from 4 different locations simultaneously

Robust PelicanStorm Case

Features

UNIPHOS FUMITRACKAutomatic Online Fumigation Gas Monitoring System

The System can monitor any of the below described ranges� Ranges: PH3: 0-2000ppm & 0-20 ppm

MBr: 0- 200 mg/L & 0-200 ppm Or combination of any two from the above

A �eld mountable online fumigation gas monitoring system for detection and continuous monitoring of di�erent fumigant gases at mitigation locations. The inbuilt multi-sampling ports having a suction capacity to draw the sample from a distance of 100 meters provides fumigators with an option to cover multiple Silo's from a single point. It gives a digital output signal that can be connected to any suitable control system(Uniphos controllers, DLC, PLCs etc) by RS-485 MODBUS-RTU. It also gives an industry standard 4-20mA analog output signal.It is available for Phosphine and Methyl Bromide