comparison between extravascular lung water, b-type natriuretic peptide and blood volume contraction...

16
Comparison between Extravascular lung water, B-type natriuretic peptide and blood volume contraction to detect weaning-induced pulmonary edema M. Dres , J-L. Teboul, N. Anguel, L. Guerin, C. Richard, X. Monnet Service de réanimation médicale, Hôpitaux universitaires Paris-Sud, Hôpital de Bicêtre EA4533, Université Paris-Sud, Le Kremlin-Bicêtre, France

Upload: jaidyn-newlin

Post on 14-Jan-2016

231 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Comparison between Extravascular lung water, B-type natriuretic peptide and blood volume contraction to detect weaning-induced pulmonary edema M. Dres,

Comparison between Extravascular lung water, B-type natriuretic peptide and blood volume

contraction to detect weaning-induced pulmonary edema

M. Dres, J-L. Teboul, N. Anguel, L. Guerin, C. Richard, X. Monnet

Service de réanimation médicale, Hôpitaux universitaires Paris-Sud, Hôpital de BicêtreEA4533, Université Paris-Sud, Le Kremlin-Bicêtre, France

Page 2: Comparison between Extravascular lung water, B-type natriuretic peptide and blood volume contraction to detect weaning-induced pulmonary edema M. Dres,

Prs Xavier Monnet and Jean-Louis Teboul: members of the Medical Advisory Board of Pulsion Medical System

Conflict of interest

Page 3: Comparison between Extravascular lung water, B-type natriuretic peptide and blood volume contraction to detect weaning-induced pulmonary edema M. Dres,

Background Methods Results Discussion

Weaning of mechanical ventilationWeaning induced pulmonary edema : frequent and treatable

Teboul JL et al. Crit Care 2010

• Clinical examination• Echocardiography• Biological : Blood volume contraction

B-type natriuretic peptide• Hemodynamic (right heart

catheter)

IND

IREC

TD

IREC

T

• Measure of extravascular lung water

Page 4: Comparison between Extravascular lung water, B-type natriuretic peptide and blood volume contraction to detect weaning-induced pulmonary edema M. Dres,

DiscussionBackground Methods Results

Transpulmonary Thermodilution

Cold bolus

EVLWGEDVPVPI…

time

ΔTemp

Page 5: Comparison between Extravascular lung water, B-type natriuretic peptide and blood volume contraction to detect weaning-induced pulmonary edema M. Dres,

Background Methods Results Discussion

To detect weaning induced pulmonary edema by showing an increase in extravascular lung water

Hypothesis:

1

To confirm the ability of an increase in BNP and in plasma protein concentration and hemoglobin to diagnose weaning induced pulmonary edema

2

Page 6: Comparison between Extravascular lung water, B-type natriuretic peptide and blood volume contraction to detect weaning-induced pulmonary edema M. Dres,

Background Methods Results Discussion

During a SBT performed

24 hours after the failure of a first SBT

Patients with right heart catheter

1.

2.

3.

Patients ready to be weaned

Measurement of EVLW BNPPlasma protein concentration hemoglobin PAOP

Weaning induced pulmonary edema : clinical intolerance + PAOP ≥18 mmHg

SBT on T-tube during 60 minutes

Baseline End of SBT

Page 7: Comparison between Extravascular lung water, B-type natriuretic peptide and blood volume contraction to detect weaning-induced pulmonary edema M. Dres,

Background Methods Results Discussion

36 SBTs

Primary analysis

Page 8: Comparison between Extravascular lung water, B-type natriuretic peptide and blood volume contraction to detect weaning-induced pulmonary edema M. Dres,

Background Methods Results Discussion

Changes in EVLW during spontaneous breathing trial

Page 9: Comparison between Extravascular lung water, B-type natriuretic peptide and blood volume contraction to detect weaning-induced pulmonary edema M. Dres,

Background Methods Results Discussion

Changes in plasma protein concentration during spontaneous breathing trial

Page 10: Comparison between Extravascular lung water, B-type natriuretic peptide and blood volume contraction to detect weaning-induced pulmonary edema M. Dres,

Background Methods Results Discussion

Changes in hemoglobin during spontaneous breathing trial

Page 11: Comparison between Extravascular lung water, B-type natriuretic peptide and blood volume contraction to detect weaning-induced pulmonary edema M. Dres,

Background Methods Results Discussion

Changes in B-type natriuretic peptide during spontaneous breathing trial

Page 12: Comparison between Extravascular lung water, B-type natriuretic peptide and blood volume contraction to detect weaning-induced pulmonary edema M. Dres,

Background Methods Results Discussion

Diagnostic performance for the detection of weaning induced pulmonary edema

Weaning-induced changes inplasma protein concentration

Weaning-induced changes inhemoglobin concentration

Weaning-induced changes inextravascular lung water

Weaning-induced changes inB-type natriuretic peptide

0 20 40 60 80 1000

20

40

60

80

100

100 - Specificity

Sens

iti vit y

0 20 40 60 80 1000

20

40

60

80

100

100 - Specificity

Sens

iti vit y

0 20 40 60 80 1000

20

40

60

80

100

100 - Specificity

Sens

iti vit y

0 20 40 60 80 1000

20

40

60

80

100

100- Specificity

Sens

iti vit y

AUC 0.96

AUC 0.76

6%

14%

AUC 0.97

AUC 0.89

Page 13: Comparison between Extravascular lung water, B-type natriuretic peptide and blood volume contraction to detect weaning-induced pulmonary edema M. Dres,

Background Methods Results Discussion

Limits of the study

Performance of BNP : pro-BNP?

Strengths of the study

Gold standard method to diagnose weaning induced pulmonary edema

Confirmation of the physiological approach by showing blood volume contraction

SBT on T-tube. Pressure support level?

Page 14: Comparison between Extravascular lung water, B-type natriuretic peptide and blood volume contraction to detect weaning-induced pulmonary edema M. Dres,

Transpulmonary thermodilution enables to detect

increase in extravascular lung water

during weaning induced pulmonary edema

Blood volume contraction confirmed its relevance as an

Non invasive alternative tool in this context

Conclusion

Page 15: Comparison between Extravascular lung water, B-type natriuretic peptide and blood volume contraction to detect weaning-induced pulmonary edema M. Dres,

Background Methods Results Discussion

12%

Page 16: Comparison between Extravascular lung water, B-type natriuretic peptide and blood volume contraction to detect weaning-induced pulmonary edema M. Dres,

Background Methods Results Discussion

Weaning induced PE +

Weaning induced PE -