condensing boiler technology
TRANSCRIPT
Issue 2015-01
Condensing boiler technology
2 3
About ebm-papst 4
Laboratory equipment 8
Systems for condensing boiler technology 10
Radial blowers 16
Gas valves 34
Burner controls 42
ebm-papst representatives & subsidiaries 48
Content
4 5
ebm-papst Landshut is the ideal partner for developing heating units.
ebm�papst Landshut is THE ideal partner for developing heating
systems.
Condensing boiler technology has been advancing steadily since the
1990s. ebm-papst Landshut has been the top supplier for premix
blowers for just as long. We were there from the start. We developed
and supplied the world’s first blower for condensing boiler technology.
However, we also developed ourselves, evolving from the largest
supplier of premix blowers to a developer of complete systems for
condensing boiler technology consisting of a blower, venturi, valve and
burner control. That, too, remains unmatched anywhere in the world.
6 7
Sustainability is at the centre of ourthoughts and actions. Out of conviction!
Eco-friendliness and sustainability have always been at the core of our thoughts and actions. For decades, we have worked according to the
simple but strict creed of our co-founder Gerhard Sturm: “Each new product we develop has to be better than the last one in terms of economy
and ecology.” GreenTech is the ultimate expression of our corporate philosophy.
GreenTech is pro-active development.
Even in the design phase, the materials and processes we use are
optimised for the greatest possible eco-friendliness, energy balance
and – wherever possible – recyclability. We continually improve the
material and performance of our products, as well as the flow and
noise characteristics. At the same time, we significantly reduce ener-
gy conumption. Close co-operation with universities and scientific
institutes and the professorship we endow in the area of power engi-
neering and regenerative energies allows us to profit from the latest
research findings in these fields – and at the same time ensures
highly qualified young academics.
GreenTech is eco-friendly production.
GreenTech also stands for maximum energy efficiency in our produc-
tion processes. There, the intelligent use of industrial waste heat and
groundwater cooling, photovoltaics and, of course, our own cooling
and ventilation technology are of the utmost importance. Our most
modern plant, for instance, consumes 91% less energy than currently
specified and required. In this way, our products contribute to protect-
ing the environment, from their origin to their recyclable packaging.
GreenTech is acknowledged and certified.
Every step in our chain of production meets the stringent standards
of environmental specialists and the public.
This supports our position as Germany’s most sustainable company
2013, as does the DEKRA Award 2012 we received in the category
“Umwelt – Herausforderung Energiewende / Environment – Chal-
lenge: Transition to more sustainable energy systems”, to name only
a few of a large number of examples. The environmental advantage
gained in the performance of the products developed from our
GreenTech philosophy can also be measured in the fulfillment of the
most stringent energy and environmental standards. In many instanc-
es, our products are already well below the thresholds energy legisla-
tion will impose a few years from now – several times over.
Our customers profit from this every day.
The heart of GreenTech is future-oriented EC technology from ebm-
papst. The EC technology at the core of our most efficient motors and
fans allows efficiency of up to 90%, saves energy at a very high level,
significantly extends service life and makes our products mainte-
nance-free. These values pay off not only for the environment, but
every cent also pays off for the user! All ebm-papst products – even
those for which GreenTech EC technology does not (yet) make sense
from an application viewpoint – feature the greatest possible connec-
tion of economy and ecology.
GreenTech isacknowledgedand certified.
GreenTech ispro-active
development.
GreenTech iseco-friendlyproduction.
GreenTechfollows a firmphilosophy.
GreenTechpays offfor our
customers.
8 9
Air performance test rig
Multiple air performance test rigs are available. They test the operat-
ing performance of the blowers and plot the air performance curves.
Spectrum analyser
The spectrum analyser can be used to measure line-bound interfer-
ence. Since our devices are used for further processing in expert
industrial companies, we are not actually required to test their elec-
tromagnetic compatibility (EMC measurement). Nevertheless, we
would like to offer this service to our customers. This tests whether
the motors fulfill the requirements of EN-55014-1, thus ensuring that
there is no interference with devices in the environment.
Climate chamber
Multiple climate chambers are available in various sizes. They enable
endurance tests to be carried out in a variety of ambient conditions
(temperature, humidity, air pressure). This also makes it possible to
determine the service life of the devices.
We have the research and development expertise needed for
continuous improvement in today’s world: Dedicated, intelligent engi-
neers and technicians who work to further develop products, co-op-
erating with our customers’ development teams. The range of analy-
ses is not limited to harmful emissions. We also analyse and optimise
EMC and noise emissions.
We support our customers in the development of applications from
the very beginning. Only when all of the necessary characteristics are
present does the product go into production. The tests required for
this purpose include both inspections for complying with legal man-
dates and specific customer requirements. Numerous measuring de-
vices are available directly at the Landshut location for this purpose.
For example, we also test for design effects, such as changes to the
gas-air manifold, check valves or the venturi. All of these factors can
influence the efficiency – as well as the noise level and function –
of a condensing boiler and must be taken into account when match-
ing the individual components to each other.
Gas laboratory
ebm-papst Landshut has a gas laboratory with state-of-the art
measuring devices. The laboratory can also take into account coun-
try-specific differences, as each country has its own legislation for
the composition of the gases and the minimum and maximum supply
pressure. The inlet pressure in the supply line can be varied to show
the effects of various supply networks. In addition, all testing and limit
gases commonly used in Europe, America and Asia are available.
We carry out exhaust gas measurements (CO2, CO, lambda) and
measurements with variable aerodynamic parameters (venturi pres-
sure, modulation range, mass flow). The climate chamber also allows
both short-term and endurance testing of external variables such
as temperature and humidity. Wind and turbulence at the air-intake
area can also be simulated. The volume of condensate produced by
the condensing effect can be determined to measure the efficiency of
the system.
Noise measurement laboratory
The noise behaviour of our blowers and systems is tested in our
soundproof noise measurement laboratory featuring state-of-the-art,
high-precision sound measuring systems. By the way, these are the
same real-world conditions in which they are built into our custom-
ers’ products.
Additional equipment
Our equipment also includes a high-resolution 3D microscope and
a 3D plotter for rapid prototyping, which can be used to fabricate
plastic parts for tests on short notice.
We can also carry out vibration tests to simulate mechanical loads,
such as those that occur during transport of the blowers. Equipment
for testing the type of protection is also available. They allow ambient
influences to be tested based on DIN EN 60529.
Laboratory equipment
10 11
Systems for condensing boiler technology
12 13
Gas blowerState-of-the-art blower technology for modulating operation with low noise and a long service life.
Condensing boiler versus conventional heating.
The difference is that in condensing boiler systems, the water vapour
present in the exhaust is condensed before exiting the fl ue and is used
to extract additional heat. Relative to conventional heating systems,
which do not use this effect, this allows a signifi cantly higher effi cien-
cy of up to 111% to be attained relative to the lower heating value.
Burner control with displayIn co-operation with ebm-papst Heating Systems, the electronic control is matched precisely to the system. Signals from the burner con-trols can be read out in the lab using LabVision software.
VenturiThe pressure generated by the venturi effect provides an optimum mixture of gas and air in the pneumatic gas-air ratio control.
Gas valveThe part required for the correct gas quan-tity has a particularly compact design.
Systems for condensing boiler technology
In times of increasingly scarce raw materials, existing energy sources
have to be used as effi ciently as possible. Therefore, it is important
to replace the old conventional heating units with high-effi ciency con-
densing boiler systems.
Design of a condensing boiler heating unit.
What can we supply you with? And what do you get out of it?
System gas-air assembly
Air Gas
GasVenturi
Blower
Burner Control with display
Burner
Gas-
air m
ixtu
reGa
s-ai
r mix
ture
on/o
ff
Valve
Perfectly matched components of a condensing boiler.
The mixture ratio of gas to air is critical for the energy yield during
combustion. If the gas content is too high, we refer to the mixture as
being too rich. Since there is not enough oxygen available, the gas is
not completely burned off and it is dissipated with the exhaust gas.
This not only wastes a lot of energy, the exhaust gases also contain
undesirable products such as carbon monoxide (CO) and carbon par-
ticulate matter. The opposite situation – when the gas content is too
low – can, in extreme cases, cause the fl ame in the burner to go out.
Therefore, having the correct mixture is of critical importance. This
is attained only if the system is optimally matched for premixing gas
and air or oxygen. This is not so easy in practice. Just one example
of a problem is the different gas qualities. Natural gas has a high
methane content and thus a lower gross calorifi c value than liquid
gas, which consists primarily of propane and butane mixtures. Bio-
gas is also being used more and more frequently. The mixture ratio
must be adjusted exactly to the gross calorifi c value of the different
gas families – as must the air pressure and the temperature of the
intake air and the supply pressure in the gas line.
Another challenge is the fl exibility of the heat output. The greater
the modulation range of a heating system, the better the heat output
can be adjusted to the current demand. The limits of the modulation
degree are determined by the minimum and maximum output of the
premix blower. Even at a low heat output, the system has to have the
ability to set the optimum mixture ratio. For this purpose, the compo-
nents – blower, venturi, valve and burner control – have to be ideally
matched to each other.
If these components are purchased from different manufacturers,
confi guring the interfaces and the operating performance optimally
is an arduous task. Therefore, it is only logical for us to supply all
four components as a fi nished system for premixing from a single
source. This enables our customers to focus entirely on their core
skills.
The following illustration shows the function of these
components.
Figure 1: Schematic design of a system
on/offSpeed control
14 15
Heating range [kW] Part number
Venturi 1 2 – 15 55734.33000
Venturi 2 5 – 28 55734.33010
Venturi 3 7 – 35 55734.33020
204 mm
178 mm
157 mm
253 mm
213 mm
234 mm
224 mm
175 mm
163 mm
Heating range [kW] Part number
Venturi 1 3 – 23 55734.32010
Venturi 2 5 – 28 55734.32020
Venturi 3 7 – 42 55734.32030
Heating range [kW] Part number
Venturi 1 15 – 90 55724.10000
Venturi 2 24 – 145 55724.10010
Our system solutions at a glance
In heating engineering, it is essential that all components are perfect-
ly co-ordinated in order to attain optimum output and efficiency.
Therefore, we offer you complete heating systems from a single
source, including gas blower, venturi and gas valve.
A substantial advantage of our venturi tubes is their optimum mixture
ratio with simultaneously high modulation ranges. To achieve this
high efficiency, we offer a variety of venturi inserts for the multi-
venturi tubes tailored to specific heating capacity ranges. In addition,
solutions with a multi-venturi offer a wide variety of options for ar-
ranging our systems in your devices. This gives you the advantage of
having the most flexible and space-saving integration possible.
For potential mounting positions, please refer to page 18. For addi-
tional potential attachment positions for a valve or specific attach-
ments for air conduction, please contact us.
A burner control perfectly matched to the system is also possible
thanks to our system partnership with ebm-papst Heating Systems,
the Netherlands-based specialist for intelligent control technology.
This can be mounted directly on the system or remotely.
We supply our systems as completely tested and fine-tuned units
with optimised interfaces to save you time and money.
Systems at a glance
NRV 77 The system for heat outputs from 2 to 35 kW
NRV 118 The system for heat outputs from 3 to 42 kW
NRV 137 The system for heat outputs from 15 to 145 kW
Consisting of:
– Gas blower NRG 77 with multi-venturi
– Gas valve GB-ND 055 E01
Sample on request.
Consisting of:
– Gas blower NRG 118 with multi-venturi
– Gas valve GB-ND 055 E01
Consisting of:
– Gas blower NRG 137 with multi-venturi
– Gas valve GB-ND 057 D01
Sample on request.Sample on request.
16 17
Radial blowers
18 19
Mounting positions
Mounting positions 1 to 5 are possible in general. For vibration-
cushioned motor installation, the motor weight is also supported by
an elastic element. Therefore, the mounting position must be speci-
fi ed. Consultation is required in conjunction with our systems and for
mounting position 6.
Venturi tubes
Venturi tubes provide for the correct ratio of air fl ow to gas fl ow.
In addition to this, the venturi’s effi ciency determines the maximum
possible modulation degree of the heating system.
Here you see the possible rotation between venturi and blower –
the gas valve is also pictured for clarifi cation:
Potential mounting positions for the multi-venturi
You can obtain further details on the available venturi variants from
your contact person on-site.
Commutation electronics
The motor electronics are integrated into the blower unit. This en-
sures that the commutation electronics are optimally tuned to the
motor. Shutoff of rotor locking and overload protection are options
that can be integrated. In individual cases, adaptation to the burner
control is required.
Speed output
The blowers with the designation HRG, NRG and RG have a Hall IC
signal output with two pulses per revolution. The G3G 250 MW has
fi ve pulses per revolution, while the G1G and G3G each have three
pulses per revolution. In the case of motors for mains voltage opera-
tion, the speed signal output is galvanically isolated.
Speed control
The speed is controlled by a pulse-width modulated signal (PWM).
You can obtain more information from your contact person on-site.
ErP 2015
ebm-papst fans with GreenTech EC technology meet the legal
requirements for ErP directive Step 2 (by 2015). This directive applies
to devices with an output greater than 125W. This catalogue provides
information on blowers NRG 137, RG 148, RG 175, G1G and G3G.
1 2 3 4 5 6
Modern gas-fi red or oil-fi red modulating condensing boilers have
to be supplied with the ideal volume and composition of air and fuel,
whatever the operating state and external conditions. Controllable
blowers with a steep pressure-fl ow rate curve and a high pressure
maximum are required for this purpose. ebm-papst played a critical
role in the development of suitable EC blowers for this and now offers
the most extensive product line for this application area. The special
properties of these blowers can, however, be used for many other
applications as well. Some examples of this include gas-powered
cookers in the food service industry and gas-powered deep fryers for
commercial use.
Basic structure
Housing
The housing of NRG, RG and G1G/G3G blower types are made of
die-cast aluminium, the housing of the HRG 134 is made of PA6 GF
plastic. The tight sealing required for gas-premix technology is
achieved by a special seal for the housing halves and the drive shaft
entry point. The special requirements, inspections and approval
criteria are co-ordinated for each individual case. The required safety
inspections for the complete functional unit have to be carried out
by the manufacturer of the terminal device.
Impellers
The impellers of HRG, NRG and RG blower types consist of pentane-
resistant plastic. They are dynamically fi ne-balanced. Models G1G 170,
G3G 200 and G3G 250 have impellers made of aluminium sheet.
Drive
The drive consists of brushless direct current (EC) motors with
integrated electronics. The motor has a vibration-free mounting to
minimise structure-borne noise.
Type of protection
The blowers fulfi ll the IP20 type of protection with cover, depending
on the mounting position.
Protection class
The motors fulfi ll the requirements for protection class I.
Bearings
Maintenance-free ball bearings covered on both sides provide for
durability and running smoothness.
Overview of blowers
Our comprehensive product portfolio offers blowers for heat output
values from 2kW to 1MW. The overview shows the available blower
types and the application area that we recommend. Please note that
the heat output actually attained in the end device depends on vari-
ous factors.
The gas type, burner and heat exchanger are just a few of the com-
ponents responsible for achieving a certain output.
0.5
Heat load in kW
1000750250 500
G3G 250 MW
G3G 250
G3G 200
G1G 170
RG 175
NRG 137
RG 148
RG 128
NRG 118
NRG 77
Radial blowers
20 21
Nominal data Rate
d vo
ltage
Freq
uenc
y
Max
. air
flow
Max
. pr
essu
re in
crea
se
Max
. inp
ut p
ower
Max
. spe
ed
Perm
. am
b. m
otor
tem
p.
Perm
. te
mp.
of m
ediu
m
Part
num
ber
Type V Hz m³/h Pa W min-1 °C °C
NRG 77 230 50/60 78 1650 50 12500 60 80 55667.70030
Subject to alterations.
Nominal data Rate
d vo
ltage
Freq
uenc
y
Max
. air
flow
Max
. pr
essu
re in
crea
se
Max
. inp
ut p
ower
Max
. spe
ed
Perm
. am
b. m
otor
tem
p.
Perm
. te
mp.
of m
ediu
m
Part
num
ber
Type V Hz m³/h Pa W min-1 °C °C
NRG 118 230 50/60 95 2500 75 8500 60 80 55667.31160
Subject to alterations.
12000
10000
8000
6000
4000
2000
10 20 30 40 50 60 70 80
12000
10000
8000
6000
4000
2000
10 20 30 40 50 60 70 80
2400
2000
1600
1200
800
400
10 20 30 40 50 60 70 80
2400
2000
1600
1200
800
400
10 20 30 40 50 60 70 80
Curves Curves
– Material: Housing: Aluminium
Impeller: Plastic
Motor protection cap: Plastic
– For potential mounting positions, page 18
– Multi-venturi available
– Mains connector X, interface connector W and interface see page 31 ff.
Dimensions in mm. Dimensions in mm.
NRG 77 NRG 118
– Material: Housing: Aluminium
Impeller: Plastic
Motor protection cap: Plastic
– For potential mounting positions, page 18
– Multi-venturi available
– Mains connector X, interface connector W and interface see page 31 ff.
22 23
Nominal data Rate
d vo
ltage
Freq
uenc
y
Max
. air
flow
Max
. pr
essu
re in
crea
se
Max
. inp
ut p
ower
Max
. spe
ed
Perm
. am
b. m
otor
tem
p.
Perm
. te
mp.
of m
ediu
m
Part
num
ber
Type V Hz m³/h Pa W min-1 °C °C
RG 128 230 50/60 150 2500 110 8400 60 80 55667.22510
Subject to alterations.
Curves
2400
2000
1600
1200
800
400
12000
10000
8000
6000
4000
2000
20 40 60 80 100 120 140 160 20 40 60 80 100 120 140 160
Nominal data Rate
d vo
ltage
Freq
uenc
y
Max
. air
flow
Max
. pr
essu
re in
crea
se
Max
. inp
ut p
ower
Max
. spe
ed
Perm
. am
b. m
otor
tem
p.
Perm
. te
mp.
of m
ediu
m
Part
num
ber
Type V Hz m³/h Pa W min-1 °C °C
RG 148 230 50/60 230 4300 200 9500 60 80 55667.25230
Subject to alterations.
Curves
3750
3000
2250
1500
750
9000
7500
6000
4500
3000
1500
30 60 90 120 150 180 210 240 30 60 90 120 150 180 210 240
Dimensions in mm. Dimensions in mm.
RG 128 RG 148
– Material: Housing: Aluminium
Impeller: Plastic
Motor protection cap: Plastic
– For potential mounting positions, page 18
– Mains connector X, interface connector W and interface see page 31 ff.
– Material: Housing: Aluminium
Impeller: Plastic
Motor protection cap: Plastic
– For potential mounting positions, page 18
– Mains connector X, interface connector W and interface see page 31 ff.
24 25
Nominal data Rate
d vo
ltage
Freq
uenc
y
Max
. air
flow
Max
. pr
essu
re in
crea
se
Max
. inp
ut p
ower
Max
. spe
ed
Perm
. am
b. m
otor
tem
p.
Perm
. te
mp.
of m
ediu
m
Part
num
ber
Type V Hz m³/h Pa W min-1 °C °C
NRG 137 230 50/60 235 3500 190 9000 60 80 55667.33110
Subject to alterations.
Curves
3000
2500
2000
1500
1000
500
9000
7500
6000
4500
3000
1500
30 60 90 120 150 180 210 240 30 60 90 120 150 180 210 240
3750
3000
2250
1500
750
50 100 150 200 250 300 350
Nominal data Rate
d vo
ltage
Freq
uenc
y
Max
. air
flow
Max
. pr
essu
re in
crea
se
Max
. inp
ut p
ower
Max
. spe
ed
Perm
. am
b. m
otor
tem
p.
Perm
. te
mp.
of m
ediu
m
Part
num
ber
Type V Hz m³/h Pa W min-1 °C °C
RG 175 230 50/60 390 3700 275 7800 60 80 55667.14090
Subject to alterations.
Curves
9000
7500
6000
4500
3000
1500
50 100 150 200 250 300 350
Dimensions in mm. Dimensions in mm.
NRG 137 RG 175
– Material: Housing: Aluminium
Impeller: Plastic
Motor protection cap: Plastic
– For potential mounting positions, page 18
– Multi-venturi available
– Mains connector X, interface connector W and interface see page 31 ff.
– Material: Housing: Aluminium
Impeller: Plastic
Motor protection cap: Plastic
– For potential mounting positions, page 18
– Mains connector X, interface connector W and interface see page 31 ff.
26 27
Nominal data Rate
d vo
ltage
Freq
uenc
y
Max
. air
flow
Max
. pr
essu
re in
crea
se
Max
. inp
ut p
ower
Max
. spe
ed
Perm
. am
b. m
otor
tem
p.
Perm
. te
mp.
of m
ediu
m
Part
num
ber
Type V Hz m³/h Pa W min-1 °C °C
G1G 170 -AB53-01 230 50/60 620 3000 360 5830 55 80 55600.01270
G1G 170 -AB53-801 230 50/60 620 3000 360 5830 55 80 55600.01350
Subject to alterations. 1) With linear input (0-10 VDC).
Nominal data Rate
d vo
ltage
Freq
uenc
y
Max
. air
flow
Max
. pr
essu
re in
crea
se
Max
. inp
ut p
ower
Max
. spe
ed
Perm
. am
b. m
otor
tem
p.
Perm
. te
mp.
of m
ediu
m
Part
num
ber
Type V Hz m³/h Pa W min-1 °C °C
G3G 200 -GN20-01 230 50/60 1150 2900 890 6100 60 60 55600.03030
Subject to alterations.
G1G 170 G3G 200
– Material: Housing: Aluminium
Impeller: Plastic
Motor protection cap: Plastic
– For potential mounting positions, page 18
– Mains connector X, interface connector W and interface see page 31 ff.
– Material: Housing: Aluminium
Impeller: Plastic
Motor protection cap: Plastic
– For potential mounting positions, page 18
– Mains connector X, interface connector W and interface see page 31 ff.
3000
2400
1800
1200
600
100 200 300 400 500 600 700
Curves
detail V
enlarged
slot for O-ring fixing
Ø110
9,5
3
6xM
8 3,5
Ø140
±0,
3
Ø 78
176 +3
257±2
273
±2
101 15
8
76,5V
view Z
cover for motorand electronics
3-pole header
5-pole header
pressure tappingconnection possible
60
120
140
97+
1
93,5
+1
Z
9
43,5X/W
5
123
135
2500
2000
1500
1000
500
200 400 600 800 1000
Curves
detail V
323,2
168 6x60°
90 ±0,1
235,5 =1,5
57
109,5
124
±0,
1
Ø9
Ø96
112,
8
117,
5
355,
5
pressure tappingconnection possible
X/W
V
140
180
Dimensions in mm.Dimensions in mm.
28 29
Nominal data Rate
d vo
ltage
Freq
uenc
y
Max
. air
flow
Max
. pr
essu
re in
crea
se
Max
. inp
ut p
ower
Max
. spe
ed
Perm
. am
b. m
otor
tem
p.
Perm
. te
mp.
of m
ediu
m
Part
num
ber
Type V Hz m³/h Pa W min-1 °C °C
G3G 250 -GN17-01 230 50/60 1650 3250 1150 4800 60 60 55600.05021
Subject to alterations.
Nominal data Rate
d vo
ltage
Freq
uenc
y
Max
. air
flow
Max
. pr
essu
re in
crea
se
Max
. inp
ut p
ower
Max
. spe
ed
Perm
. am
b. m
otor
tem
p.
Perm
. te
mp.
of m
ediu
m
Part
num
ber
Type V Hz m³/h Pa W min-1 °C °C
G3G 250 -MW50-01 380 - 480 50/60 2200 5400 2500 6400 50 50 G3G 250 -MW50-01
Subject to alterations.
G3G 250 G3G 250 MW
– Material: Housing: Aluminium
Impeller: Plastic
Motor protection cap: Plastic
– For potential mounting positions, page 18
– Mains connector X, interface connector W and interface see page 31 ff.
– Material: Housing: Die-cast aluminium
Impeller: Sheet aluminium
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium
– For mains connector see operating instructions
3000
2500
2000
1500
1000
500
400 800 1200 1400
Curves
249 ±1,5
120,5
92
180
Ø120
66,3
169,
8
9
171
6x60°
60°
view Z
2,9
10 +1
M8
3,4 Ø1
85
Ø220
detail V enlarged
sideplates of housingsealed with rubber loop(NBR pentane-resistant)
V
Z
434 ±1
459
±1
265
pressure tapping is possible
8
204,5
X/W
220
Ø220
178,
6+0,
3
5
2,9-0,3
10+1
M8
459±
1
265
434±1
204,5
66,3
6x60°
220
180
92
Ø9
Ø120
395±2
120,5
171
169,
8
5000
4000
3000
2000
1000
400 800 1200 1600 2000
Curves
cable gland
view Z
detail V
Ø120
Z
V
sideplates of housingsealed with rubber loop(NBR pentane-resistant)
Dimensions in mm.Dimensions in mm.
30 31
Power supply ACPower supply ACProtective earth
Part number for mating connector:Connector shell 24309.45012; Crimp socket 24307.45002/3
1 = Power supply +2 = Hall Sensor OUT3 = NC4 = PWM Input5 = Power supply - (GND)
1 = Power supply +2 = Hall Sensor OUT3 = PWM Input4 = GND
1 3 5
2 4 6
Part number for mating connector: 24310.45025 Part number for mating connector:Connector shell 24310.45133;Crimp socket 24300.45128
Part number for mating connector:Connector shell 24309.45035;Crimp socket 24308.45065
1 = Power supply +2 = Hall Sensor OUT3 = NC4 = PWM Input5 = Power supply - (GND)
Part number for mating connector:Connector shell 24309.45035;Crimp socket 24308.45065
1 = Power supply +2 = Hall Sensor OUT3 = Input 0-10V DC Control4 = PWM Input5 = Power supply - (GND)
Part number for mating connector:Connector shell 24309.45035;Crimp socket 24308.45065
3-pin pin-connector with coding type 0A according to RAST 5in 90° angled / horizontal designwith locking feature on top or down for locking devicesuitable for mating connector according to RAST 5with coding type 0A as e. g.CoHaMo YY-A5002-H03-K01 or Lumberg 3623 03 K01
Power supply AC
Protective earth
Power supply AC
3-pin pin-connector according RAST 6.35in 90° angled / horizontal designsuitable for mating connector according to RAST 6.35e. g. Tyco Universal MATE-N-LOKorder number: 1586847-1 and 3 x socket 926882-1
4-pin pin-connector according RAST 3.0in 90° angled / horizontal designsuitable for mating connector according to RAST 3.0e. g. Molex Micro-Fit 3.0order number: 43645-0408and 4 x socket 43030-0001
5-pin pin-connector according RAST 4.2in 90° angled / horizontal designsuitable for mating connector according to RAST 4.2e. g. Stocko STO-FIT, CoHaMoorder number: Stocko EH 705-005-004-960and 5 x socket RBB 8230.120order number: CoHaMo YY-5700-H05AS-GW
5-pin pin-connector according RAST 4.2in 90° angled / horizontal designsuitable for mating connector according to RAST 4.2e. g. Stocko STO-FIT, CoHaMoorder number: Stocko EH 705-005-004-960and 5 x socket RBB 8230.120order number: CoHaMo YY-5700-H05AS-GW
5-pin pin-connector according RAST 4.2in 90° angled / horizontal design suitable for mating connector according to RAST 4.2e. g. Stocko STO-FIT, CoHaMoorder number: Stocko EH 705-005-004-960and 5 x socket RBB 8230.120order number: CoHaMo YY-5700-H05AS-GW
Power supply ACPower supply ACProtective earth
Part number for mating connector:Connector shell 24309.45012; Crimp socket 24307.45002/3
1 = Power supply +2 = Hall Sensor OUT3 = NC4 = PWM Input5 = Power supply - (GND)
1 = Power supply +2 = Hall Sensor OUT3 = PWM Input4 = GND
1 3 5
2 4 6
Part number for mating connector: 24310.45025 Part number for mating connector:Connector shell 24310.45133;Crimp socket 24300.45128
Part number for mating connector:Connector shell 24309.45035;Crimp socket 24308.45065
1 = Power supply +2 = Hall Sensor OUT3 = NC4 = PWM Input5 = Power supply - (GND)
Part number for mating connector:Connector shell 24309.45035;Crimp socket 24308.45065
1 = Power supply +2 = Hall Sensor OUT3 = Input 0-10V DC Control4 = PWM Input5 = Power supply - (GND)
Part number for mating connector:Connector shell 24309.45035;Crimp socket 24308.45065
3-pin pin-connector with coding type 0A according to RAST 5in 90° angled / horizontal designwith locking feature on top or down for locking devicesuitable for mating connector according to RAST 5with coding type 0A as e. g.CoHaMo YY-A5002-H03-K01 or Lumberg 3623 03 K01
Power supply AC
Protective earth
Power supply AC
3-pin pin-connector according RAST 6.35in 90° angled / horizontal designsuitable for mating connector according to RAST 6.35e. g. Tyco Universal MATE-N-LOKorder number: 1586847-1 and 3 x socket 926882-1
4-pin pin-connector according RAST 3.0in 90° angled / horizontal designsuitable for mating connector according to RAST 3.0e. g. Molex Micro-Fit 3.0order number: 43645-0408and 4 x socket 43030-0001
5-pin pin-connector according RAST 4.2in 90° angled / horizontal designsuitable for mating connector according to RAST 4.2e. g. Stocko STO-FIT, CoHaMoorder number: Stocko EH 705-005-004-960and 5 x socket RBB 8230.120order number: CoHaMo YY-5700-H05AS-GW
5-pin pin-connector according RAST 4.2in 90° angled / horizontal designsuitable for mating connector according to RAST 4.2e. g. Stocko STO-FIT, CoHaMoorder number: Stocko EH 705-005-004-960and 5 x socket RBB 8230.120order number: CoHaMo YY-5700-H05AS-GW
5-pin pin-connector according RAST 4.2in 90° angled / horizontal design suitable for mating connector according to RAST 4.2e. g. Stocko STO-FIT, CoHaMoorder number: Stocko EH 705-005-004-960and 5 x socket RBB 8230.120order number: CoHaMo YY-5700-H05AS-GW
Mains connector X
Mains connector X
1 3
4
5
62
Interface connector W
Interface connector W
Interface connector W
Interface connector W
Power supply ACPower supply ACProtective earth
Part number for mating connector:Connector shell 24309.45012; Crimp socket 24307.45002/3
1 = Power supply +2 = Hall Sensor OUT3 = NC4 = PWM Input5 = Power supply - (GND)
1 = Power supply +2 = Hall Sensor OUT3 = PWM Input4 = GND
1 3 5
2 4 6
Part number for mating connector: 24310.45025 Part number for mating connector:Connector shell 24310.45133;Crimp socket 24300.45128
Part number for mating connector:Connector shell 24309.45035;Crimp socket 24308.45065
1 = Power supply +2 = Hall Sensor OUT3 = NC4 = PWM Input5 = Power supply - (GND)
Part number for mating connector:Connector shell 24309.45035;Crimp socket 24308.45065
1 = Power supply +2 = Hall Sensor OUT3 = Input 0-10V DC Control4 = PWM Input5 = Power supply - (GND)
Part number for mating connector:Connector shell 24309.45035;Crimp socket 24308.45065
3-pin pin-connector with coding type 0A according to RAST 5in 90° angled / horizontal designwith locking feature on top or down for locking devicesuitable for mating connector according to RAST 5with coding type 0A as e. g.CoHaMo YY-A5002-H03-K01 or Lumberg 3623 03 K01
Power supply AC
Protective earth
Power supply AC
3-pin pin-connector according RAST 6.35in 90° angled / horizontal designsuitable for mating connector according to RAST 6.35e. g. Tyco Universal MATE-N-LOKorder number: 1586847-1 and 3 x socket 926882-1
4-pin pin-connector according RAST 3.0in 90° angled / horizontal designsuitable for mating connector according to RAST 3.0e. g. Molex Micro-Fit 3.0order number: 43645-0408and 4 x socket 43030-0001
5-pin pin-connector according RAST 4.2in 90° angled / horizontal designsuitable for mating connector according to RAST 4.2e. g. Stocko STO-FIT, CoHaMoorder number: Stocko EH 705-005-004-960and 5 x socket RBB 8230.120order number: CoHaMo YY-5700-H05AS-GW
5-pin pin-connector according RAST 4.2in 90° angled / horizontal designsuitable for mating connector according to RAST 4.2e. g. Stocko STO-FIT, CoHaMoorder number: Stocko EH 705-005-004-960and 5 x socket RBB 8230.120order number: CoHaMo YY-5700-H05AS-GW
5-pin pin-connector according RAST 4.2in 90° angled / horizontal design suitable for mating connector according to RAST 4.2e. g. Stocko STO-FIT, CoHaMoorder number: Stocko EH 705-005-004-960and 5 x socket RBB 8230.120order number: CoHaMo YY-5700-H05AS-GW
Power supply ACPower supply ACProtective earth
Part number for mating connector:Connector shell 24309.45012; Crimp socket 24307.45002/3
1 = Power supply +2 = Hall Sensor OUT3 = NC4 = PWM Input5 = Power supply - (GND)
1 = Power supply +2 = Hall Sensor OUT3 = PWM Input4 = GND
1 3 5
2 4 6
Part number for mating connector: 24310.45025 Part number for mating connector:Connector shell 24310.45133;Crimp socket 24300.45128
Part number for mating connector:Connector shell 24309.45035;Crimp socket 24308.45065
1 = Power supply +2 = Hall Sensor OUT3 = NC4 = PWM Input5 = Power supply - (GND)
Part number for mating connector:Connector shell 24309.45035;Crimp socket 24308.45065
1 = Power supply +2 = Hall Sensor OUT3 = Input 0-10V DC Control4 = PWM Input5 = Power supply - (GND)
Part number for mating connector:Connector shell 24309.45035;Crimp socket 24308.45065
3-pin pin-connector with coding type 0A according to RAST 5in 90° angled / horizontal designwith locking feature on top or down for locking devicesuitable for mating connector according to RAST 5with coding type 0A as e. g.CoHaMo YY-A5002-H03-K01 or Lumberg 3623 03 K01
Power supply AC
Protective earth
Power supply AC
3-pin pin-connector according RAST 6.35in 90° angled / horizontal designsuitable for mating connector according to RAST 6.35e. g. Tyco Universal MATE-N-LOKorder number: 1586847-1 and 3 x socket 926882-1
4-pin pin-connector according RAST 3.0in 90° angled / horizontal designsuitable for mating connector according to RAST 3.0e. g. Molex Micro-Fit 3.0order number: 43645-0408and 4 x socket 43030-0001
5-pin pin-connector according RAST 4.2in 90° angled / horizontal designsuitable for mating connector according to RAST 4.2e. g. Stocko STO-FIT, CoHaMoorder number: Stocko EH 705-005-004-960and 5 x socket RBB 8230.120order number: CoHaMo YY-5700-H05AS-GW
5-pin pin-connector according RAST 4.2in 90° angled / horizontal designsuitable for mating connector according to RAST 4.2e. g. Stocko STO-FIT, CoHaMoorder number: Stocko EH 705-005-004-960and 5 x socket RBB 8230.120order number: CoHaMo YY-5700-H05AS-GW
5-pin pin-connector according RAST 4.2in 90° angled / horizontal design suitable for mating connector according to RAST 4.2e. g. Stocko STO-FIT, CoHaMoorder number: Stocko EH 705-005-004-960and 5 x socket RBB 8230.120order number: CoHaMo YY-5700-H05AS-GW
Power supply ACPower supply ACProtective earth
Part number for mating connector:Connector shell 24309.45012; Crimp socket 24307.45002/3
1 = Power supply +2 = Hall Sensor OUT3 = NC4 = PWM Input5 = Power supply - (GND)
1 = Power supply +2 = Hall Sensor OUT3 = PWM Input4 = GND
1 3 5
2 4 6
Part number for mating connector: 24310.45025 Part number for mating connector:Connector shell 24310.45133;Crimp socket 24300.45128
Part number for mating connector:Connector shell 24309.45035;Crimp socket 24308.45065
1 = Power supply +2 = Hall Sensor OUT3 = NC4 = PWM Input5 = Power supply - (GND)
Part number for mating connector:Connector shell 24309.45035;Crimp socket 24308.45065
1 = Power supply +2 = Hall Sensor OUT3 = Input 0-10V DC Control4 = PWM Input5 = Power supply - (GND)
Part number for mating connector:Connector shell 24309.45035;Crimp socket 24308.45065
3-pin pin-connector with coding type 0A according to RAST 5in 90° angled / horizontal designwith locking feature on top or down for locking devicesuitable for mating connector according to RAST 5with coding type 0A as e. g.CoHaMo YY-A5002-H03-K01 or Lumberg 3623 03 K01
Power supply AC
Protective earth
Power supply AC
3-pin pin-connector according RAST 6.35in 90° angled / horizontal designsuitable for mating connector according to RAST 6.35e. g. Tyco Universal MATE-N-LOKorder number: 1586847-1 and 3 x socket 926882-1
4-pin pin-connector according RAST 3.0in 90° angled / horizontal designsuitable for mating connector according to RAST 3.0e. g. Molex Micro-Fit 3.0order number: 43645-0408and 4 x socket 43030-0001
5-pin pin-connector according RAST 4.2in 90° angled / horizontal designsuitable for mating connector according to RAST 4.2e. g. Stocko STO-FIT, CoHaMoorder number: Stocko EH 705-005-004-960and 5 x socket RBB 8230.120order number: CoHaMo YY-5700-H05AS-GW
5-pin pin-connector according RAST 4.2in 90° angled / horizontal designsuitable for mating connector according to RAST 4.2e. g. Stocko STO-FIT, CoHaMoorder number: Stocko EH 705-005-004-960and 5 x socket RBB 8230.120order number: CoHaMo YY-5700-H05AS-GW
5-pin pin-connector according RAST 4.2in 90° angled / horizontal design suitable for mating connector according to RAST 4.2e. g. Stocko STO-FIT, CoHaMoorder number: Stocko EH 705-005-004-960and 5 x socket RBB 8230.120order number: CoHaMo YY-5700-H05AS-GW
Power supply ACPower supply ACProtective earth
Part number for mating connector:Connector shell 24309.45012; Crimp socket 24307.45002/3
1 = Power supply +2 = Hall Sensor OUT3 = NC4 = PWM Input5 = Power supply - (GND)
1 = Power supply +2 = Hall Sensor OUT3 = PWM Input4 = GND
1 3 5
2 4 6
Part number for mating connector: 24310.45025 Part number for mating connector:Connector shell 24310.45133;Crimp socket 24300.45128
Part number for mating connector:Connector shell 24309.45035;Crimp socket 24308.45065
1 = Power supply +2 = Hall Sensor OUT3 = NC4 = PWM Input5 = Power supply - (GND)
Part number for mating connector:Connector shell 24309.45035;Crimp socket 24308.45065
1 = Power supply +2 = Hall Sensor OUT3 = Input 0-10V DC Control4 = PWM Input5 = Power supply - (GND)
Part number for mating connector:Connector shell 24309.45035;Crimp socket 24308.45065
3-pin pin-connector with coding type 0A according to RAST 5in 90° angled / horizontal designwith locking feature on top or down for locking devicesuitable for mating connector according to RAST 5with coding type 0A as e. g.CoHaMo YY-A5002-H03-K01 or Lumberg 3623 03 K01
Power supply AC
Protective earth
Power supply AC
3-pin pin-connector according RAST 6.35in 90° angled / horizontal designsuitable for mating connector according to RAST 6.35e. g. Tyco Universal MATE-N-LOKorder number: 1586847-1 and 3 x socket 926882-1
4-pin pin-connector according RAST 3.0in 90° angled / horizontal designsuitable for mating connector according to RAST 3.0e. g. Molex Micro-Fit 3.0order number: 43645-0408and 4 x socket 43030-0001
5-pin pin-connector according RAST 4.2in 90° angled / horizontal designsuitable for mating connector according to RAST 4.2e. g. Stocko STO-FIT, CoHaMoorder number: Stocko EH 705-005-004-960and 5 x socket RBB 8230.120order number: CoHaMo YY-5700-H05AS-GW
5-pin pin-connector according RAST 4.2in 90° angled / horizontal designsuitable for mating connector according to RAST 4.2e. g. Stocko STO-FIT, CoHaMoorder number: Stocko EH 705-005-004-960and 5 x socket RBB 8230.120order number: CoHaMo YY-5700-H05AS-GW
5-pin pin-connector according RAST 4.2in 90° angled / horizontal design suitable for mating connector according to RAST 4.2e. g. Stocko STO-FIT, CoHaMoorder number: Stocko EH 705-005-004-960and 5 x socket RBB 8230.120order number: CoHaMo YY-5700-H05AS-GW
Nominal data Rate
d vo
ltage
Freq
uenc
y
Max
. air
flow
Max
. pr
essu
re in
crea
se
Max
. inp
ut p
ower
Max
. spe
ed
Perm
. am
b. m
otor
tem
p.
Perm
. te
mp.
of m
ediu
m
Part
num
ber
Type V Hz m³/h Pa W min-1 °C °C
HRG 134 230 50/60 78 3000 70 8500 60 80 55667.40160
Subject to alterations.
9000
7500
6000
4500
3000
1500
10 20 30 40 50 60 70
Curves
3000
2500
2000
1500
1000
500
10 20 30 40 50 60 70
Dimensions in mm.
HRG 134for oil condensing boilers
– Material: Housing: Plastic
Impeller: Plastic
Motor protection cap: Plastic
– For potential mounting positions, page 18
– Mains connector X, interface connector W and interface see page 31 ff.
Connectors
Connectors NRG
77
NRG
118
RG 1
28
RG 1
48
NRG
137
RG 1
75
G1G
170
-AB5
3-01
G1G
170
-AB5
3-80
G3G
200
G3G
250
HRG
134
G3G
250
MW
Inte
rface
04
600.
451…
1 Mains connector X × × × × × × ×
see
oper
atin
g in
stru
ctio
ns2 Mains connector X × × × ×
3 Interface connector W × 31
4 Interface connector W × × × × × × 04
5 Interface connector W × 38
6 Interface connector W × × × 39
Further connector types on request.
32 33
Electrical interfaces Electrical interfaces
Interface 31
Interface 04
115 / 230 VACInterface 38
230 VAC, 50/60 Hz 120 VAC, 50/60 Hz control Interface 39 115 / 230 VAC
04600.45131 04600.45138
04600.45104
Further types on request. Further types on request.
04600.45139
counter
controller
alarm
speed display
maximum ripple ±3,5% UB +24 - 45VDC / 15mA
nominal voltage
tach output 3 pulses / revolution
open PWM andcontrol input-> max. speed
Fuse
Fuse
min.operation->Ucontrol>2V
voltage output+10V max 10mA
tach output3 pulses per revolution
lin. control input
VACground
main voltage
counter
speed setting speed settingspeed
setting with alterable
resistance
controller
alarm
speed display
safe start up at 25% PWMcontrol signal - square pulsePWM-Low -> blower off PWM-High -> blower on
starting -> PWM > 25%min. operation -> PWM 18%control input signal - rectangle impulsPWM-Low - fan offPWM-High - fan on
Customer circuit example Interface ebm-papst circuit
HS out
GND
VCC
PW Min
GND
18-43VDC1
HS2
PW M
GND
3
12K
1K
22K
10nF
4K7
4
12K22
K
7.5V
15K
12V1K
Customer circuit example Customer circuit exampleInterface Interfaceebm-papst circuit ebm-papst circuit
Customer circuit example Interface ebm-papst circuit
Standardschnittstelle 1 24 VDC Steuerung
Standardschnittstelle 2 230 VAC, 50/60 Hz 120 VAC, 50/60 Hz Steuerung
Schnittstellen für Gebläse mit EC-Innenläufermotor BG3612/3633
Drehzahl-auswertung
PWM:Start: >20% PWMRechtecksignalPWM-low = Gebläse ausPWM-high = Gebläse ein
12K
1K8)*
1K2)*
10K10K
10K
10K
10K
15K
+12 VDC
+12 VDC+12 VDC
+12 VDC
12KPC817
BC546B
12K
12K
EMV-Filter
Vcc
Hall Signal
PWM-SignalGND
1K
15K
1K
PC817
BC846B
1K
6K8
ZMM
5,1
ZMM
12
1K
L (187 V ... 253 V 50/60 Hz)(91V ... 126 V 50/60 Hz)
+18..43 VDC
Hallsignal2 Pulse pro Umdrehung
3 N.C.
5 GND
PWM 1-6 kHz
Imax = 3,3mA
Imax, „High“: 1,6mAImax, „Low“: -2,0mA
PE
1
2
4
PWM:Start: >20% PWMRechtecksignalPWM-low = Gebläse ausPWM-high = Gebläse ein
+18..43 VDC
Hallsignal2 Pulse pro Umdrehung
3 N.C.
5 GND
PWM 1-6 kHz
Imax, „High“: 5mAImax, „Low“: -2,0mA
1
2
4
I
N
Kundenseite Schnittstelle ebm-papst Seite
Kundenseite Schnittstelle
8 mm Isolation (Kriechstecke)
Hallsensor mitOpen KollektorAusgang
ebm-papst Seite
85
Allg
emei
nes
Quer
stro
mve
ntila
tore
nRa
dial
gebl
äse
ACRa
dial
gebl
äse
ECUm
wäl
zgeb
läse
für H
eißl
uft
Axia
lven
tilat
oren
Pum
pen
Adre
ssen
tach output2 pulses per revolution
Digital PWMPWM-low = Blower offPWM-high = Blower on
34 35
Gas valves
36 37
Our zero-pressure gas valves for gas-condensing systems are primarily
used for domestic applications in the lower and medium power range.
These gas valves compensate for pressure fl uctuations occurring in
the public gas grid as well as regulate the offset pressure to zero re-
gardless of the suction pressure being generated by a premix blower.
The offset (zero point shift) can be confi gured at the servo regulator.
At the same time the desired gas quantity can be adjusted by using
an integrated throttle element. Both together ensure an accurate air-
gas ratio setting.
Depending on the design a reference pressure can be connected to
the servo regulator if required.
Technical information
Length 105mm
Permitted gas families II + III (in accordance with EN 437)
Maximum inlet pressure 65mbar (CE), 0,5psi (CSA)
Permitted ambient temperature 0°C to 60°C
(-15°C to 70°C on request)
Permitted storage temperature -25°C to 70°C
Type of protection IP40 in combination with
a suitable plug
Offset correction +/- 20Pa
Minimum signal pressure -30Pa
Permitted mounting position Solenoid at any position between
vertical and horizontal –
but not upside down.
Type�examination certifi cate in accordance with EC Gas
Appliances Directive: CE�0085CM0036 (product ID number)
Applicable standards
– EN126:2012�06: Multifunctional controls for gas burning appliances
– EN13611:2007 + A2:2011: Safety and control devices for gas
burners and gas burning appliances – General requirements
– EN161:2012�08: Automatic shut-off valves for gas burners and gas
appliances
– EN88-1:2011: Pressure regulators and associated safety devices
for gas appliances – Part 1: Pressure regulators for inlet pressures
up to and including 50kPa
Type�examination certifi cate for North America (USA and Canada):
Master Contract No. 172723
Applicable standards
– ANSI Z21.78�2010 / CSA 6.20�2010:
Combination Gas Controls for Gas Appliances
Approvals exist for the chief gas�consuming countries.
Additional notes
– Work on the gas valve may be performed by authorised
specialists only.
– Please be sure to observe the corresponding installation instructions.
– Corresponding documents with safety instructions are available
upon request or on the Internet.
Approvals and applicable standardsGas valves
38 39
– Housing: Aluminium
– Electrical connection: Connector shell with 4.20mm grid
– Inlet (gas connection): External thread G3/4 or G1/2 (DIN EN ISO 228)
or 4 x M4 mounting holes (optional)
– Outlet: ebm-papst specific quick-connector
– Safety valves: Coaxial design: valve class B/C in accordance with EN161
Vn [m3/h] Erdgas / Natural gas (dv = 0,65) °
∆p [m
bar]
2
3
4
5
6
1
8
10
20
30
40
60
80
100
50
2 3 4 5 6 71 8 9 10 20
Bedingungen: + 15° C / 59 °F, p = 1013 mbar
0,1 0,2 0,3 0,4 0,5 0,6 0,8
2 3 4 5 6 71 8 9 10 20 300,2 0,3 0,4 0,5 0,6 0,8
Vn [m3/h] Luft / Air (dv = 1,00) °
Capacity curve – GB055
electrical connectionsolenoid coil
main flow throttlepressure test nipple P1
pressure test nipple P2
servo regulator
– Housing: Aluminium
– Electrical connection: Connector shell with 5.08mm grid
– Inlet (gas connection): 4 x M5 mounting holes (36mm hole spacing)
– Outlet: 4 x M5 mounting holes (36mm hole spacing)
– Safety valves: Valve class B/B in accordance with EN161
Nominal data Rate
d vo
ltage
Max
. inp
ut p
ower
Nom
inal
dia
met
er
Max
imum
inle
t pr
essu
re
Flow
rate
(a
t Δp
= 5
mba
r)
Auto
mat
ic
shut
off v
alve
s (E
N161
)
Min
imum
si
gnal
pre
ssur
e
Open
ing
and
cl
osin
g tim
e
Type V VA mbar m³/h Pa s
GB-ND 057 D01 230 RAC 2 x 12.5 DN20 65 5.3 Class B/B -30 < 1
120 RAC 2 x 12.5 DN20 65 5.3 Class B/B -30 < 1
24 RAC 2 x 12.5 DN20 65 5.3 Class B/B -30 < 1
24 DC 2 x 12.5 DN20 65 5.3 Class B/B -30 < 1
Bedingungen + 15°C, 1013 mbar, trocken
V°n [m3/h] Erdgas / Natural gas (dv = 0,65)
V°n [m3/h] Luft / Air (dv = 1,00)
empfohlener Arbeitsbereich
∆p [m
bar]
2 3 4 5 6 71
2 3 4 5 6 71
8 9 10
71 8 9 10
20
20 30
0,1 0,2 0,3 0,4 0,5 0,6
0,2 0,3 0,4 0,5 0,6
0,8
0,8
∆
2
3
4
5
6
1
8
10
20
30
40
60
80
100
50
Capacity curve – GB057
electrical connection
solenoid coilmain flow throttle
pressure test nipple P1
pressure test nipple P2
servo regulator
pressure regulatoroffset adjustment
recommended work range
recommended work range
E01Size GB055
D01Size GB057
Nominal data Rate
d vo
ltage
Max
. inp
ut p
ower
Nom
inal
dia
met
er
Max
imum
in
let p
ress
ure
Flow
rate
(a
t Δp
= 5
mba
r)
Auto
mat
ic
shut
off v
alve
s (E
N161
)
Min
imum
si
gnal
pre
ssur
e
Open
ing
and
cl
osin
g tim
e
Type V VA mbar m³/h Pa s
GB-ND 055 E01 230 RAC 9.8 DN15/20 65 3.4 Class B/C -30 < 1
120 RAC 9.8 DN15/20 65 3.4 Class B/C -30 < 1
24 RAC 9.8 DN15/20 65 3.4 Class B/C -30 < 1
24 DC 9.8 DN15/20 65 3.4 Class B/C -30 < 1
22 DC 9.8 DN15/20 65 3.4 Class B/C -30 < 1
40 41
F01
– Housing: Aluminium
– Electrical connection: Connector shell with 4.20mm grid
– Inlet (gas connection): External thread G3/4 or G1/2 (DIN EN ISO 228)
– Outlet: ebm-papst specific quick-connector
– Safety valves: Coaxial design: valve class B/C in accordance with EN161
Nominal data Rate
d vo
ltage
Max
. inp
ut p
ower
Nom
inal
dia
met
er
Max
imum
in
let p
ress
ure
Flow
rate
(a
t Δp
= 5
mba
r)St
eppe
r mot
or m
odul
e w
ith n
omin
al
diam
eter
8m
m
Flow
rate
(a
t Δp
= 5
mba
r)St
eppe
r mot
or m
odul
e w
ith n
omin
al
diam
eter
12m
m
Auto
mat
ic
shut
off v
alve
s (E
N161
)
Open
ing
and
cl
osin
g tim
e
Type V VA mbar m³/h m³/h s
GB-SXX 06X F01 230 RAC 9.8 DN15/20 60 2.1 2.9 Class B/C < 1
120 RAC 9.8 DN15/20 60 2.1 2.9 Class B/C < 1
24 RAC 9.8 DN15/20 60 2.1 2.9 Class B/C < 1
24 DC 9.8 DN15/20 60 2.1 2.9 Class B/C < 1
22 DC 9.8 DN15/20 60 2.1 2.9 Class B/C < 1
Capacity curve – F01
electrical connection stepper motor module
electrical connection safety valve
solenoid coilG 3/4" or G1/2" ISO 228-1
pressure test nipple
∆p
[mba
r]∆
1
10
100
V°n [m3/h] Erdgas / Natural gas
V°n [m3/h] Luft / Air
0,01 0,1 1 10
°
0,0135 0,135 1,35 13,5
F01 - 12 mm
F01 - 8 mm
Bedingungen: 15° C, p=1013 mbar
empfohlener Arbeitsbereichrecommended work range
42 43
Burner Controls
44 45
In co-operation with the Dutch electronic control unit specialist ebm-
papst Heating Systems B.V. (formerly Argus Vision B.V.), we also offer
our customers a control element for their gas heaters from a single
source. ebm-papst Heating Systems already has 20 years of experi-
ence in developing burner controls to look back on and also has the
required expertise for mastering the current challenges in condensing
boiler technology. In modulating condensing boilers, the link between
mechanical components and the electronic drive has to be co-ordi-
nated with a high-degree of precision in order to achieve optimum
combustion beha viour. ebm-papst Heating Systems earned a reputa-
tion for the highest innovative strength and quality in electronic moni-
toring for gas-fi res heating systems.
ebm-papst Heating Systems supplies the electronics for controlling
ignition, performance regulation and monitoring the function of
the condensing boiler as well as a user input interface with various
displays for conveniently controlling central heating and DHW. The
burner control can also be used in combination with other modules
and provide control with a system regulation, for example a cascade
operation.
The standard platform, consisting of tried-and-tested hardware and
software, enables reliable operating performance and short develop-
ment cycles. The versatile software architecture enables customer-
specifi c interfaces to be integrated with ease. In addition, as with our
blowers, we value having the lowest possible energy consumption.
Markets and application areas
Gas fi red combi-boilers, commercial gas boilers, air heaters, direct
fi red water heaters, indirect fi red water heaters, gas stoves, catering
equipment such as fryers and mCHP.
Service tools
LabVision computer software for communication between computer
and burner control.
System in operation
Trio / Multiple Trio Application
– Function: To control central heating, DHW, cascade operation, multiple burners
(trio and multiple trio). No additional controller needed.
– Application: Domestic (combi) boilers, commercial boilers, water heaters
– Connections: Supports a wide range of in- and outputs for sensors, valves,
ignition, pumps, etc.
– Support: LabVision PC Software, to confi gure hard- and software functions,
remote diagnostics, logging and graphs
Nominal data Pow
er s
uppl
y
Freq
uenc
y
Dim
ensi
ons
hous
ing
l x w
x h
Safe
ty ti
me
Igni
tion
atte
mpt
s
Wei
ght
On B
oard
Us
er In
terfa
ce
Even
t his
tory
(e
rror
& lo
ckou
t)
Argu
s Li
nk
LabV
isio
n Di
agno
stic
s So
ftwar
e
Type VAC Hz mm Sec. gram
850MN 230 40-70 212 x 152 x 46 6 3 530 No 15 + 15 x x
850MN 120 40-70 212 x 152 x 46 6 3 530 No 15 + 15 x x
900MN 230 40-70 212 x 152 x 49 6 3 512 Yes 15 + 15 x x
Features
– Low standby power consumption and class A modulating
pump control
– Insensitivity of mains supply for a reliable operation
– Thermostat options: Switched Live, OT-interface or 24V
– Connect controls with each other via Argus Link
(2-wire communication interface)
– Wide choice of control modules for hybrid heating applications
and systems within a building or house
– Easy interfacing with Building Management Systems,
for example via ModBUS
900MN Burner Control
230V
GASAC or DC
230VNTC 7X ARGUS LINK
or 24VACIGNITIONINT or EXT
230VON 2X / 1X PWMOFF
230V PWM or DIGIT AL
IN SWITCH2X
5V SENSOR 2X
3X
850MN Burner Control
230V
GASAC or DC
230VNTC 6X SWITCH ARGUS LINK
or 24VACIGNITIONINT or EXT
230V230V PWM or DIGIT AL
5V SENSOR
900MN Burner Control
230V
GASAC or DC
230VNTC 7X ARGUS LINK
or 24VACIGNITIONINT or EXT
230VON 2X / 1X PWMOFF
230V PWM or DIGIT AL
IN SWITCH2X
5V SENSOR 2X
3X
850MN Burner Control
230V
GASAC or DC
230VNTC 6X SWITCH ARGUS LINK
or 24VACIGNITIONINT or EXT
230V230V PWM or DIGIT AL
5V SENSOR
Burner Control UnitsBurner Controls
46 47
– Function: External display modules to be used as an user interface for burner
controls or optional modules
– Integrated features: User and installer menu, multiple languages and graphics
– Optional features: Specifi c application menus, for example solar control and
catering equipment
– 2�Wire Argus Link: One connection for power and communication
Nominal data Di
men
sion
s (l
x w
x h
)
LCD
type
Disp
lay
Colo
r
Back
light
LCD
disp
lay
Area
(l
x h)
No. o
f Pus
h Bu
ttons
Avai
labl
e w
ith
hous
ing
Conn
ectio
n
Mul
tiple
lang
uage
s
Tem
p. S
enso
r
Real
Tim
e Cl
ock
Type mm mm
900PB 178 x 85 x 13 Pixel 255 x 80 blue/white x 106.4 x 39 8 2-wire x x
900DI 142 x 63.5 x 29 Icons & segment green/black x 37 x 22 5 2-, 3- or 4-wire
900LB 119 x 115 x 20 Icons & segment blue/white x 93 x 31 5 2- or 4-wire optional
850HC 129 x 129 x 24 Pixel 255 x 80 blue/white x 106.4 x 39 11 x 2-wire x x x
– Function optional modules: Add-on modules to extend your system
– Argus Link Interface: To connect easily to other controls
– Support: RemoteVision PC Software, for monitoring, controlling and
data-logging of fi eld appliances via a permanent TCP/IP internet connection
(also available as SiteVision for installers)
Nominal data Pow
er S
uppl
y
Dim
ensi
ons
(l x
w x
h)
Wei
ght
Argu
s Li
nk
Type VAC mm gram
850DS 87 x 50 x 27 45 x
850IF 110V/230 155 x 110 x 51 439 x
850SC 110V/230 150 x 105 x 14 525 x
850GP 110V/230 150 x 105 x 14 254 x
850USB 78 x 54 x 28 116 x
850GP GPRS Communication Module Wireless communication module using GPRS technology
850USB PC Communication Interface For communication between the PC/LabVision and the control
850SC Solar ControlControl for thermal solar heat systems with or without drainback tank
850DS Digital SensorRobust outdoor or room temperature sensor
850SC Solar ControlControl for thermal solar heat systems with or without drain-back tank
850IF Interface ModuleInterface Module to extend several heat generation control modules
T RETURN NTC 3X
850SC Solar Control
230V
ARGUS LINK
5V FLOW24V STEPPER 230V MODQ-SOLAR + T SYSTEM
T COLLECT OR T STORE
850IF Interface Module
ARGUS LINK
EXT RESET INALARM OUT
STATUS OUT
T RETURN NTC 3X
850SC Solar Control
230V
ARGUS LINK
5V FLOW24V STEPPER 230V MODQ-SOLAR + T SYSTEM
T COLLECT OR T STORE
850IF Interface Module
ARGUS LINK
EXT RESET INALARM OUT
STATUS OUT
Displays Optional Modules
900DI LCD Display
900LB LCD Display900PB Pixel Display
48 49
ebm-papst in Germany ebm-papst in Europe
ebm-papst Mulfi ngen GmbH & Co. KGBachmühle 274673 Mulfi ngenGERMANYPhone +49 7938 81-0Fax +49 7938 [email protected]
ebm-papst St. Georgen GmbH & Co. KGHermann-Papst-Straße 178112 St. GeorgenGERMANYPhone +49 7724 81-0Fax +49 7724 [email protected]
ebm-papst Landshut GmbHHofmark-Aich-Straße 2584030 LandshutGERMANYPhone +49 871 707-0Fax +49 871 [email protected]
BerlinDipl.-Ing. (TH) Jens DuchowHändelstraße 716341 PanketalGERMANYPhone +49 30 944149-62Fax +49 30 [email protected]
BielefeldDipl.-Ing. (FH) Wolf-Jürgen WeberNiehausweg 1333739 BielefeldGERMANYPhone +49 5206 91732-31Fax +49 5206 [email protected]
DortmundDipl.-Ing. (FH) Hans-Joachim PundtAuf den Steinern 359519 Möhnesee-VöllinghausenGERMANYPhone +49 2925 800-407Fax +49 2925 [email protected]
FrankfurtDipl.-Ing. Christian KleffmannDr.-Hermann-Krause-Straße 2363452 HanauGERMANYPhone +49 6181 1898-12Fax +49 6181 [email protected]
HalleDipl.-Ing. (TU) Michael HanningLercheneck 406198 Salzatal / OT LieskauGERMANYPhone +49 345 55124-56Fax +49 345 [email protected]
HamburgIngenieurbüro Breuell GmbHIng. Dirk KahlElektroingenieurGrützmühlenweg 4822339 HamburgGERMANYPhone +49 40 538092-19Fax +49 40 [email protected]
Heilbronn / HeidelbergDipl.-Ing. Mark GartnerGehrweg 1274199 UnterheinrietGERMANYPhone +49 7130 404569-1Fax +49 7130 [email protected]
KasselDipl.-Ing. (FH) Ralph BrückHoherainstraße 3 b35075 GladenbachGERMANYPhone +49 6462 4071-10Fax +49 6462 [email protected]
KoblenzWinfried SchaeferHinter der Kirch 1056767 UersfeldGERMANYPhone +49 2657 16-96Fax +49 2657 [email protected]
MunichDipl.-Wirt.-Ing. (FH) Jens PeterLandsbergerstraße 1486932 PürgenGERMANYPhone +49 8196 99877-54Fax +49 8196 [email protected]
NurembergDipl.-Wirt.-Ing. (FH) Axel ReschDr.-August-Koch-Str. 191639 Wolframs-EschenbachGERMANYPhone +49 9875 9783-170Fax +49 9875 [email protected]
OffenburgDipl.-Ing. (FH) Ralf BraunHubeneck 2177704 OberkirchGERMANYPhone +49 7802 9822-52Fax +49 7802 [email protected]
StuttgartDipl.-Ing. (FH) Rudi WeinmannHindenburgstraße 100/173207 PlochingenGERMANYPhone +49 7153 9289-80Fax +49 7153 [email protected]
UlmM.Sc. Reinhard SommerreißerAm Germanenring 1386674 Baar / SchwabenGERMANYPhone +49 8276 5899-775Fax +49 8276 [email protected]
Distributors
FrankfurtR.E.D. Handelsgesellschaft mbHGutenbergstraße 363110 Rodgau - JügesheimGERMANYPhone +49 6106 841-0Fax +49 6106 [email protected]
HamburgBreuell + Hilgenfeldt GmbHGrützmühlenweg 4822339 HamburgGERMANYPhone +49 40 538092-20Fax +49 40 [email protected]
MunichA. Schweiger GmbHOhmstraße 182054 SauerlachGERMANYPhone +49 8104 897-0Fax +49 8104 [email protected]
(1 to 5 pieces)
NorthBreuell + Hilgenfeldt GmbHGrützmühlenweg 4822339 HamburgGERMANYPhone +49 40 538092-20Fax +49 40 [email protected]
SouthHDS Ventilatoren Vertriebs GmbHGlaswiesenstraße 174677 DörzbachGERMANYPhone +49 7937 80355-20Fax +49 7937 [email protected]
Europe
Austriaebm-papst Motoren & Ventilatoren GmbHStraubingstraße 174030 LinzAUSTRIAPhone +43 732 321150-0Fax +43 732 [email protected]
Belarusebm-papst Bel AgmbHLipkovskaya Gasse 34Offi ce No.6, Room 106,107223010 MinskBELARUSPhone +375 17 3851556Fax +375 17 [email protected]
Belgiumebm-papst Benelux B.V.Sales offi ce Belgium-LuxemburgRomeinsestraat 6/0101Research Park Haasrode3001 Heverlee-LeuvenBELGIUMPhone +32 16 396-200Fax +32 16 [email protected]
Bulgariaebm-papst Romania S.R.L.Str. Tarnavei No. 20500327 BrasovROMANIAPhone +40 268 331859Fax +40 268 [email protected]
Croatiaebm-papst Industries Kft.Ezred u. 2.1044 BudapestHUNGARYPhone +36 1 8722-190Fax +36 1 8722-194offi [email protected]
Czech Republic / Slovakiaebm-papst CZ s.r.o.Kaštanová 34a620 00 BrnoCZECH REPUBLICPhone +420 544 502-411Fax +420 547 [email protected]
Denmarkebm-papst Denmark ApSVallensbækvej 212605 BrøndbyDENMARKPhone +45 43 631111Fax +45 43 [email protected]
Estoniaebm-papst Oy, Eesti FiliaalKesk tee 13Aaviku küla, Jüri Tehnopark75301 Rae Vald, HarjumaaESTONIAPhone +372 65569-78Fax +372 65569-79www.ebmpapst.ee
Finlandebm-papst OyPuistotie 102760 EspooFINLANDPhone +358 9 887022-0Fax +358 9 [email protected] www.ebmpapst.fi
Franceebm-papst sarlZI Nord - rue A. MohlerBP 6267212 Obernai CedexFRANCEPhone +33 820 326266Fax +33 3 [email protected]
GreeceHelcomaTh. Rotas & Co OEDavaki 6517672 Kallithea-AttikiGREECEPhone +30 210 9513-705Fax +30 210 [email protected]
Hungaryebm-papst Industries Kft.Ezred u. 2.1044 BudapestHUNGARYPhone +36 1 8722-190Fax +36 1 8722-194offi [email protected]
IcelandRJ EngineersStangarhyl 1a110 ReykjavikICELANDPhone +354 567 8030Fax +354 567 [email protected]
Irelandebm-papst UK Ltd.Chelmsford Business ParkChelmsford Essex CM2 5EZUNITED KINGDOMPhone +44 1245 468555Fax +44 1245 [email protected]
AuBren LimitedPortlaoise Business & Technology ParkMountrath RoadPortlaoise, Co. LaoisIRELANDPhone +353 57 8664343Fax +353 57 [email protected]
Italyebm-papst SrlVia Cornaggia 10822076 Mozzate (Co)ITALYPhone +39 0331 836201Fax +39 0331 [email protected]
Macedoniaebm-papst Industries Kft.Ezred u. 2.1044 BudapestHUNGARYPhone +36 1 8722-190Fax +36 1 8722-194offi [email protected]
fan agent compact fan agent motor specialist motor agent
50 51
ebm-papst in America and Africaebm-papst in Europe
Netherlandsebm-papst Benelux B.V.Polbeemd 75741 TP Beek en DonkTHE NETHERLANDSPhone: +31 49250 2900Fax: +31 49250 [email protected]
ebm-papst Heating Systems B.V.Van Veldekekade 3605216 KT’s-HertogenboschTHE NETHERLANDSPhone +31 73 64889-00Fax +31 73 [email protected]
Norwayebm-papst ASP.B. 173 Holmlia1203 OsloNORWAYPhone +47 22 763340Fax +47 22 [email protected]
Polandebm-papst Polska Sp. z o.o.ul. Annopol 4A03236 WarszawaPOLANDPhone +48 22 6757819Fax +48 22 6769587offi [email protected]
Portugalebm-papst (Portugal), Lda.Centro Empresarial de AlvercaRua de Adarse, Vale D’ErvasCorpo D / Fracção 32615-178 Alverca do RibatejoPORTUGALPhone +351 218 394 880Fax +351 218 394 [email protected]
Romaniaebm-papst Romania S.R.L.Str. Tarnavei Nr. 20500327 BrasovROMANIAPhone +40 268 331859Fax +40 268 [email protected]
Russiaebm-papst Ural GmbHPosadskaja-Strasse, 23(E), 3620102 EkaterinburgRUSSIAPhone +7 343 2338000Fax +7 343 [email protected]
ebm-papst Rus GmbHproezd 4529, vladenie 5, stroenie 1141000 Mytistschi, Oblast MoskauRUSSIAPhone +7 495 9807524Fax +7 495 [email protected]
Serbia & Montenegroebm-papst Industries Kft.Ezred u. 2.1044 BudapestHUNGARYPhone +36 1 8722-190Fax +36 1 8722-194offi [email protected]
Spainebm-papst Ibérica S.L.Avda. del Sistema Solar, 2928830 San Fernando de Henares (Madrid)SPAINPhone +34 91 6780894Fax +34 91 [email protected]
Swedenebm-papst ABÄggelundavägen 217562 JärfällaSWEDENPhone +46 10 4544400Fax +46 8 [email protected]
Switzerlandebm-papst AGRütisbergstrasse 18156 OberhasliSWITZERLANDPhone +41 44 73220-70Fax +41 44 [email protected]
TurkeyAkantel Elektronik San. Tic. LTD. Sti.Atatürk Organize SanayiBölgesi 10007 SK. No.:635620 Cigli-IzmirTURKEYPhone +90 232 3282090Fax +90 232 [email protected]
Ukraineebm-papst Ukraine LLCLepse Boulevard, 4, Building 2103067 KievUKRAINEPhone +38 044 2063091Fax +38 044 2063091 [email protected]
United Kingdomebm-papst UK Ltd.Chelmsford Business ParkChelmsford Essex CM2 5EZUNITED KINGDOMPhone +44 1245 468555Fax +44 1245 [email protected]
ebm-papst Automotive & Drives (UK) Ltd.The SmithyFidlers LaneEast Ilsley, Berkshire RG20 7LGUNITED KINGDOMPhone +44 1635 2811-11Fax +44 1635 2811-61A&[email protected]
America
Argentinaebm-papst de Argentina S.A.Hernandarias 148 Lomas del MiradorPcia. de Buenos Aires (1752)ARGENTINAPhone +54 11 46576135Fax +54 11 [email protected]
Brasilebm-papst Motores Ventiladores Ltda.Av. José Giorgi, 301 Galpões B6+B7Condominio Logical Center06707-100 Cotia - São PauloBRAZILPhone +55 11 4613-8700Fax +55 11 [email protected]
Canadaebm-papst Canada Inc.1800 Ironstone Manor, Unit 2Pickering, Ontario, L1W3J9CANADAPhone +1 905 420-3533Fax +1 905 [email protected]
Mexicoebm Industrial S. de R.L. de C.V.Paseo de Tamarindos 400-A-5to PisoCol. Bosques de las LomasMexico 05120, D.F.MEXICOPhone +52 55 3300-5144Fax +52 55 [email protected]
USAebm-papst Inc.P.O. Box 4009100 Hyde RoadFarmington, CT 06034UNITED STATESPhone +1 860 674-1515Fax +1 860 [email protected]
ebm-papst Automotive & Drives, Inc.3200 Greenfi eld, Suite 255Dearborn, MI 48120UNITED STATESPhone +1 313 406-8080Fax +1 313 [email protected]
Africa
South Africaebm-papst South Africa (Pty) Ltd.P.O. Box 31241119 Yacht Avenue2040 HoneydewSOUTH AFRICAPhone +27 11 794-3434Fax +27 11 [email protected]
fan agent compact fan agent motor specialist motor agent
52 53
ebm-papst in Asia and Australia
fan agent compact fan agent motor specialist motor agent
Asia
Chinaebm-papst Ventilator (Shanghai) Co., Ltd.No. 418, Huajing RoadWaiGaoQiao Free Trade ZoneNo. 2001, Yang Gao (N) Road200131 ShanghaiP.R. of CHINAPhone +86 21 5046-0183Fax +86 21 [email protected]
Hong Kongebm-papst Hong Kong Ltd.Room 17E, MG Tower133 Hoi Bun Road, Kwun TongHong KongP.R. of CHINAPhone +852 2145-8678Fax +852 [email protected]
Indiaebm-papst India Pvt. Ltd.26/3, G.N.T. Road, ErukkencherryChennai-600118INDIAPhone +91 44 25372556Fax +91 44 [email protected]
Indonesiaebm-papst IndonesiaRepresentative Offi ceGerman Centre, 4th Floor, Suite 4470Jl. Kapt. Subijono Dj. Bumi Serpong Damai15321 TangerangINDONESIAPhone +62 21 5376250Fax +62 21 [email protected]
IsraelPolak Bros. Import Agencies Ltd.9 Hamefalsim StreetKiryat Arie, Petach-Tikva 49514ISRAELPhone +972 3 9100300Fax +972 3 [email protected]
Japanebm-papst Japan K.K.Attend on Tower 13FShinyokohama 2-8-12, Kohoku-ku222-0033 Yokohama-City, KanagawaJAPANPhone +81 45 47057-51Fax +81 45 [email protected]
Koreaebm-papst Korea Co. Ltd.6F, Trutec Bldg.12, WorldCupbuk-ro 56-gilMapo-Gu Seoul 121-835KOREAPhone +82 2 366213-24Fax +82 2 [email protected] www.ebmpapst.co.kr
Malaysiaebm-papst MalaysiaRepresentative Offi ceUnit 12-2, Jalan USJ Sentral 3Persiaran Subang, Selangor Darul Ehsan47600 Subang JayaMALAYSIAPhone +60 3 8024-1680Fax +60 3 [email protected]
Singaporeebm-papst SEA Pte. Ltd.No. 23 Ubi Road 4#06-00 Olympia Industrial BuildingSingapore 408620SINGAPOREPhone +65 65513789Fax +65 [email protected]
TaiwanETECO Engineering & Trading Corp.10F-I, No. 92, Teh-Wei Str.Tsow-Inn District, KaohsiungTAIWANPhone +886 7 557-4268Fax +886 7 [email protected]
Thailandebm-papst Thailand Co., Ltd.99/9 Moo 2, Central Chaengwattana Tower14th Floor, Room 1402Chaengwattana Road Bangtarad, Pakkret11120 NonthaburiTHAILANDPhone +66 2 8353785-7Fax +66 2 [email protected]
United Arab Emiratesebm-papst Middle East FZEPO Box 17755Jebel Ali Free Zone / FZS1 / AP05DubaiUNITED ARAB EMIRATESPhone +971 4 88608-26Fax +971 4 [email protected]
Vietnamebm-papst VietnamRepresentative Offi ceRoom #102, 25 Nguyen Van Thu StreetDistrict 1Ho Chi Minh CityVIETNAMPhone +84 8 39104099Fax +84 8 [email protected]
Oceania
Australiaebm-papst A&NZ Pty Ltd.10 Oxford RoadLaverton North, Victoria, 3026AUSTRALIAPhone +61 3 9360-6400Fax +61 3 [email protected]
New Zealandebm-papst A&NZ Pty Ltd.61 Hugo Johnston Drive, Unit HPenrose 1061, AucklandNEW ZEALANDPO Box 112278,Penrose 1642, AucklandPhone +64 9 525-0245Fax +64 9 [email protected]
54 55
Notes
ebm-papst
Heating Systems B.V.
Van Veldekekade 360
5216 KT’s-Hertogenbosch
The Netherlands
Phone +31 73 64889-00
Fax +31 73 64889-11
www.ebmpapst.comwww.ebmpapst-hs.nl
ebm-papst
Landshut GmbH
Hofmark-Aich-Straße 25
84030 Landshut
Germany
Phone +49 871 707-0
Fax +49 871 707-465
Raw materials are becoming increasingly more valuable. Therefore
heaters have to become increasingly more efficient. Condensing boil-
er technology has long since replaced outdated conventional heating
systems. System solutions from ebm-papst incorporate the next im-
portant step towards greater efficiency: Instead of expending signifi-
cant effort co-ordinating individual components from various suppli-
ers, our customers receive complete condensing heating systems
from a single source, including blower, venturi, valve and burner con-
trol. This ensures optimal combustion under all conditions while re-
ducing installation effort to a minimum.
Simply contact us for more information or a specific quote. We are al-
ways there for you.
The engineer’s choice
37895-7-8811 · 2015-01 · OD-1,0'
Printed in Germany