cooldrawer™ multi-temperature drawer · drawer panel benchtop drawer panel false panel a d e c b...

8
WARNING! Electrical shock hazard Disconnect product from main power supply before installing appliance. Failure to do so may result in electrical shock or death Important safety precautions! Installation of the CoolDrawer™ requires competent mechanical and electrical skills. Be sure to leave these Instructions with the Customer. Installation must comply with your local building and electricity regulations. At the completion of the CoolDrawer™ installation, the Installer must perform the Final Checklist. Remove all packaging materials supplied with the CoolDrawer™. The CoolDrawer™ is manufactured for indoor use only. Important! SAVE THESE INSTRUCTIONS The models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our website fisherpaykel.com or contact your local Fisher & Paykel dealer. SAFETY AND WARNINGS WARNING! Cut hazard Take care - panel edges are sharp. Failure to use caution could result in injury or cuts. 1 The CoolDrawer™ MUST be installed to allow for future removal from the enclosure if service is required. Do not seal the CoolDrawer™ into the cabinetry with silicone or glue. Doing so will make future servicing difficult. Fisher & Paykel will not be liable for any costs associated with removing or replacing a sealed-in product, nor for repairing any damage that may be incurred by doing this. Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the power supply cord. Failure to install the CoolDrawer™ correctly will invalidate any warranty or liability claims. If the power supply cord is damaged, it must be replaced. Parts are available from your Authorised Fisher & Paykel dealer. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capacities, or lack of experience and knowledge unless they are supervised or given instruction concerning use of the appliance. Cabinetry must be sufficiently robust to support a combined product and food load of 220 lb (100 kg). Bearers may be required to support the internal shelf. Before you install the CoolDrawer™, please ensure that The switched power outlet must be outside the refrigerator drawer cavity so that it is accessible after installation. The switched power outlet must be located outside the cavity, within 55” (1400 mm) from the CoolDrawer™ cavity if situated on the left-hand side of the cavity and within 33 ” (850 mm) if situated on the right-hand side of the cavity. The services hole in the refrigerator cavity needs to be large enough for the power supply plug to fit through. WARNING! Tipping hazard Do not operate this apppliance until it has been securely anchored inside the cabinetry. The cabinet must be securely anchored to the floor. Failure to use caution could result in injury or cuts. COOLDRAWER™ MULTI-TEMPERATURE DRAWER INSTALLATION INSTRUCTIONS RB36S & RB90S models FRAMELESS CABINETRY

Upload: others

Post on 13-Jul-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: COOLDRAWER™ MULTI-TEMPERATURE DRAWER · Drawer Panel Benchtop Drawer panel False panel A D E C B Integrated Panel material 5 /8 - 13 16” (16 - 20 mm) panel thickness (3/4” [18

Important!Disconnect power to surrounding appliances before preparing cavity.

Recommended to allow the vertical removal of the refrigerator bins.

WARNING! Electrical shock hazard

Disconnect product from main power supply before installing appliance.

Failure to do so may result in electrical shock or death

Important safety precautions! Installation of the CoolDrawer™ requires competent mechanical and electrical skills. Be sure to leave these Instructions with the Customer. Installation must comply with your local building and electricity regulations. At the completion of the CoolDrawer™ installation, the Installer must perform the Final Checklist. Remove all packaging materials supplied with the CoolDrawer™. The CoolDrawer™ is manufactured for indoor use only.

Important! SAVE THESE INSTRUCTIONSThe models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our website fisherpaykel.com or contact your local Fisher & Paykel dealer.

SAFETY AND WARNINGS

WARNING! Cut hazard

Take care - panel edges are sharp.

Failure to use caution could result in injury or cuts.

1 The CoolDrawer™ MUST be installed to allow for future removal from the enclosure if service is required.

Do not seal the CoolDrawer™ into the cabinetry with silicone or glue. Doing so will make future servicing difficult. Fisher & Paykel will not be liable for any costs associated with removing or replacing a sealed-in product, nor for repairing any damage that may be incurred by doing this.

Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the power supply cord.

Failure to install the CoolDrawer™ correctly will invalidate any warranty or liability claims. If the power supply cord is damaged, it must be replaced. Parts are available from your Authorised

Fisher & Paykel dealer. This appliance is not intended for use by persons (including children) with reduced physical, sensory or

mental capacities, or lack of experience and knowledge unless they are supervised or given instruction concerning use of the appliance.

Cabinetry must be sufficiently robust to support a combined product and food load of 220 lb (100 kg). Bearers may be required to support the internal shelf.

Before you install the CoolDrawer™, please ensure that The switched power outlet must be outside the refrigerator drawer cavity so that it is accessible after

installation. The switched power outlet must be located outside the cavity, within 55” (1400 mm) from the

CoolDrawer™ cavity if situated on the left-hand side of the cavity and within 33 1/2” (850 mm) if situated on the right-hand side of the cavity.

The services hole in the refrigerator cavity needs to be large enough for the power supply plug to fit through.

PARTS SUPPLIED4

5 CAVITY PREPARATION

WARNING! Tipping hazard

Do not operate this apppliance until it has been securely anchored inside the

cabinetry. The cabinet must be securely anchored to the floor.

Failure to use caution could result in injury or cuts.

Installation trims (2)

Installation brackets (left-hand and right-hand side) (2)

Outlet duct (1)Trim brackets (4) Drawer Panel attachment hooks (3)

Power cord (1)

Note: Services can be located

either side of CoolDrawer™.

Benchtop

Pane

l

Phillips 5/8” (16 mm) wood screw (6)

Pan Head5/8” (16 mm)screw (12)

Pan Head5/8” (16 mm) screw (2)

Phillips 5/8” (16 mm ) wood screws (6)

2 PRODUCT DIMENSIONS

Product dimensions (inches [mm])

CoolD

rawer™

RB36S RB90S

A overall height of product (inc. installation brackets) 25 3/16” (640)

B overall width of product 33 11/16” (855)

C overall depth of product (excl. drawer panel; inc. power cord) 21 15/16” (557)

D depth of drawer (open) (excl. handle) 20 1/2” (520)

Installation diagrams for illustration purposes only

A

DH

Cabinetry dimensions (inches [mm])

CoolD

rawer™

RB36S RB90S

A overall width of cabinetry frame 35 1/2” (900)

B minimum inside width of cabinetry frame 34” (864)

C internal height of cabinetry to top of spacer block 25 3/8” (644)

D internal height of cabinetry*(to allow for product and outlet duct height)

min. 26 1/4” (665)max. 30 1/16” (764)

E minimum height of toe kick 3” (75)

F minimum depth** of toe kick 1 5/8” (40)

G minimum distance from front of cabinetry to rear wall 22 1/16” (560)

H width of spacer blocks 1 15/16” (50)*Minimum internal height of cabinetry can be 25 3/8” (644 mm) if outlet duct is not used.

**All depth measurements are taken from the front face of the cabinetry frame (not drawer panel)

Minimum clearances (inches [mm])

1/2” (13 mm)

1/16” (2 mm)

E

BC

D

G

F

F

C

G

6 INTEGRATED PANEL PREPARATION

AB

3 CABINETRY DIMENSIONS

An internal shelf can be used as an alternative to spacer blocks to position the product at the correct height. In this case additional cutouts will be required. Refer to Step 7.

Installation diagrams for illustration purposes only

Drawer Panel

5/8 - 3/16” (16-20 mm)

False Panel35 1/4” (896 mm)

height of False Panel

3/16” (4 mm)

D height of Drawer

Panel

Benchtop

Dra

wer

pan

elFa

lse

pan

el

A

D

E

C

B

Integrated Panel material

5/8 - 13/16” (16 - 20 mm) panel thickness (3/4” [18 mm] recommended). Maximum weight of 15.5 lb (7 kg). Adequately sealed to withstand moisture (122OF/50OC @ 80% RH).

Height of Drawer Panel

The following information is required to correctly define your drawer panel height:

Dimension Data SourceA Clearance between top of Drawer panel and underside Your kitchen designer of benchtop B Height between underside of cabinetry ceiling Your kitchen designer and underside of benchtop C Internal height of cabinetry to top of spacer block 25 3/8” (644 mm)D Drawer panel height Calculated from A, B, C & EE Bottom face of Drawer panel to top of spacer block Your kitchen designer (to ensure that bottom cover of product is not exposed) (Min. 6 1/16” [154 mm])

(Max. 7 1/4” [184 mm])

To calculate D complete the following equation:

D = C + B - A - E

i.e. For the F&P prefinished panel:18 3/4” (476 mm) = 25 3/8” (644 mm) + 11/16” (18 mm) - 1/16” (2 mm) - 7 1/4” (184 mm)

Height of the False Panel

Determine the height of the false panel according to your individual kitchen cabinetry requirements maintaining a 3/16” (4 mm) gap between panels.

F&P prefinish panel width is 35 1/4” (896 mm) assuming a 1/16” (2 mm) clearance either side of panel height (D) is 18 3/4” (476 mm). Note B must be min. 5/8” (16 mm) to ensure adequate clearance to benchtop.

SIDE VIEW

max. 33 1/2” (850 mm)

min. 21” (535 mm)

min. 5” (130 mm)

min. 21” (535 mm)

min. 5” (130 mm)

min. ø 1 15/16” (50 mm)

max. 3/4” 20 mm

Shows cutout if cabinetry depth at minimum 21 5/8” (550 mm)

Installation diagrams for illustration purposes only

COOLDRAWER™ MULTI-TEMPERATURE DRAWER

INSTALLATION INSTRUCTIONS

RB36S & RB90S models FRAMELESS CABINETRY

Page 2: COOLDRAWER™ MULTI-TEMPERATURE DRAWER · Drawer Panel Benchtop Drawer panel False panel A D E C B Integrated Panel material 5 /8 - 13 16” (16 - 20 mm) panel thickness (3/4” [18

Important!Disconnect power to surrounding appliances before preparing cavity.

Recommended to allow the vertical removal of the refrigerator bins.

WARNING! Electrical shock hazard

Disconnect product from main power supply before installing appliance.

Failure to do so may result in electrical shock or death

Important safety precautions! Installation of the CoolDrawer™ requires competent mechanical and electrical skills. Be sure to leave these Instructions with the Customer. Installation must comply with your local building and electricity regulations. At the completion of the CoolDrawer™ installation, the Installer must perform the Final Checklist. Remove all packaging materials supplied with the CoolDrawer™. The CoolDrawer™ is manufactured for indoor use only.

Important! SAVE THESE INSTRUCTIONSThe models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our website fisherpaykel.com or contact your local Fisher & Paykel dealer.

SAFETY AND WARNINGS

WARNING! Cut hazard

Take care - panel edges are sharp.

Failure to use caution could result in injury or cuts.

1 The CoolDrawer™ MUST be installed to allow for future removal from the enclosure if service is required.

Do not seal the CoolDrawer™ into the cabinetry with silicone or glue. Doing so will make future servicing difficult. Fisher & Paykel will not be liable for any costs associated with removing or replacing a sealed-in product, nor for repairing any damage that may be incurred by doing this.

Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the power supply cord.

Failure to install the CoolDrawer™ correctly will invalidate any warranty or liability claims. If the power supply cord is damaged, it must be replaced. Parts are available from your Authorised

Fisher & Paykel dealer. This appliance is not intended for use by persons (including children) with reduced physical, sensory or

mental capacities, or lack of experience and knowledge unless they are supervised or given instruction concerning use of the appliance.

Cabinetry must be sufficiently robust to support a combined product and food load of 220 lb (100 kg). Bearers may be required to support the internal shelf.

Before you install the CoolDrawer™, please ensure that The switched power outlet must be outside the refrigerator drawer cavity so that it is accessible after

installation. The switched power outlet must be located outside the cavity, within 55” (1400 mm) from the

CoolDrawer™ cavity if situated on the left-hand side of the cavity and within 33 1/2” (850 mm) if situated on the right-hand side of the cavity.

The services hole in the refrigerator cavity needs to be large enough for the power supply plug to fit through.

PARTS SUPPLIED4

5 CAVITY PREPARATION

WARNING! Tipping hazard

Do not operate this apppliance until it has been securely anchored inside the

cabinetry. The cabinet must be securely anchored to the floor.

Failure to use caution could result in injury or cuts.

Installation trims (2)

Installation brackets (left-hand and right-hand side) (2)

Outlet duct (1)Trim brackets (4) Drawer Panel attachment hooks (3)

Power cord (1)

Note: Services can be located

either side of CoolDrawer™.

Benchtop

Pane

l

Phillips 5/8” (16 mm) wood screw (6)

Pan Head5/8” (16 mm)screw (12)

Pan Head5/8” (16 mm) screw (2)

Phillips 5/8” (16 mm ) wood screws (6)

2 PRODUCT DIMENSIONS

Product dimensions (inches [mm])

CoolD

rawer™

RB36S RB90S

A overall height of product (inc. installation brackets) 25 3/16” (640)

B overall width of product 33 11/16” (855)

C overall depth of product (excl. drawer panel; inc. power cord) 21 15/16” (557)

D depth of drawer (open) (excl. handle) 20 1/2” (520)

Installation diagrams for illustration purposes only

A

DH

Cabinetry dimensions (inches [mm])

CoolD

rawer™

RB36S RB90S

A overall width of cabinetry frame 35 1/2” (900)

B minimum inside width of cabinetry frame 34” (864)

C internal height of cabinetry to top of spacer block 25 3/8” (644)

D internal height of cabinetry*(to allow for product and outlet duct height)

min. 26 1/4” (665)max. 30 1/16” (764)

E minimum height of toe kick 3” (75)

F minimum depth** of toe kick 1 5/8” (40)

G minimum distance from front of cabinetry to rear wall 22 1/16” (560)

H width of spacer blocks 1 15/16” (50)*Minimum internal height of cabinetry can be 25 3/8” (644 mm) if outlet duct is not used.

**All depth measurements are taken from the front face of the cabinetry frame (not drawer panel)

Minimum clearances (inches [mm])

1/2” (13 mm)

1/16” (2 mm)

E

BC

D

G

F

F

C

G

6 INTEGRATED PANEL PREPARATION

AB

3 CABINETRY DIMENSIONS

An internal shelf can be used as an alternative to spacer blocks to position the product at the correct height. In this case additional cutouts will be required. Refer to Step 7.

Installation diagrams for illustration purposes only

Drawer Panel

5/8 - 3/16” (16-20 mm)

False Panel35 1/4” (896 mm)

height of False Panel

3/16” (4 mm)

D height of Drawer

Panel

Benchtop

Dra

wer

pan

elFa

lse

pan

el

A

D

E

C

B

Integrated Panel material

5/8 - 13/16” (16 - 20 mm) panel thickness (3/4” [18 mm] recommended). Maximum weight of 15.5 lb (7 kg). Adequately sealed to withstand moisture (122OF/50OC @ 80% RH).

Height of Drawer Panel

The following information is required to correctly define your drawer panel height:

Dimension Data SourceA Clearance between top of Drawer panel and underside Your kitchen designer of benchtop B Height between underside of cabinetry ceiling Your kitchen designer and underside of benchtop C Internal height of cabinetry to top of spacer block 25 3/8” (644 mm)D Drawer panel height Calculated from A, B, C & EE Bottom face of Drawer panel to top of spacer block Your kitchen designer (to ensure that bottom cover of product is not exposed) (Min. 6 1/16” [154 mm])

(Max. 7 1/4” [184 mm])

To calculate D complete the following equation:

D = C + B - A - E

i.e. For the F&P prefinished panel:18 3/4” (476 mm) = 25 3/8” (644 mm) + 11/16” (18 mm) - 1/16” (2 mm) - 7 1/4” (184 mm)

Height of the False Panel

Determine the height of the false panel according to your individual kitchen cabinetry requirements maintaining a 3/16” (4 mm) gap between panels.

F&P prefinish panel width is 35 1/4” (896 mm) assuming a 1/16” (2 mm) clearance either side of panel height (D) is 18 3/4” (476 mm). Note B must be min. 5/8” (16 mm) to ensure adequate clearance to benchtop.

SIDE VIEW

max. 33 1/2” (850 mm)

min. 21” (535 mm)

min. 5” (130 mm)

min. 21” (535 mm)

min. 5” (130 mm)

min. ø 1 15/16” (50 mm)

max. 3/4” 20 mm

Shows cutout if cabinetry depth at minimum 21 5/8” (550 mm)

Installation diagrams for illustration purposes only

COOLDRAWER™ MULTI-TEMPERATURE DRAWER

INSTALLATION INSTRUCTIONS

RB36S & RB90S models FRAMELESS CABINETRY

Page 3: COOLDRAWER™ MULTI-TEMPERATURE DRAWER · Drawer Panel Benchtop Drawer panel False panel A D E C B Integrated Panel material 5 /8 - 13 16” (16 - 20 mm) panel thickness (3/4” [18

Important!Disconnect power to surrounding appliances before preparing cavity.

Recommended to allow the vertical removal of the refrigerator bins.

WARNING!Electrical shock hazard

Disconnect product from main power supply before installing appliance.

Failure to do so may result in electrical shock or death

Important safety precautions! Installation of the CoolDrawer™ requires competent mechanical and electrical skills.Be sure to leave these Instructions with the Customer.Installation must comply with your local building and electricity regulations.At the completion of the CoolDrawer™ installation, the Installer must perform the Final Checklist.Remove all packaging materials supplied with the CoolDrawer™.The CoolDrawer™ is manufactured for indoor use only.

Important! SAVE THESE INSTRUCTIONSThe models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our website fisherpaykel.com or contact your local Fisher & Paykel dealer.

SAFETY AND WARNINGS

WARNING!Cut hazard

Take care - panel edges are sharp.

Failure to use caution could result in injury or cuts.

1

The CoolDrawer™ MUST be installed to allow for future removal from the enclosure if service is required. Do not seal the CoolDrawer™ into the cabinetry with silicone or glue. Doing so will make future servicing difficult. Fisher & Paykel will not be liable for any costs associated with removing or replacing a sealed-in product, nor for repairing any damage that may be incurred by doing this. Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to thepower supply cord.Failure to install the CoolDrawer™ correctly will invalidate any warranty or liability claims.If the power supply cord is damaged, it must be replaced. Parts are available from your AuthorisedFisher & Paykel dealer.This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capacities, or lack of experience and knowledge unless they are supervised or given instruction concerning use of the appliance. Cabinetry must be sufficiently robust to support a combined product and food load of 220 lb (100 kg).Bearers may be required to support the internal shelf.

Before you install the CoolDrawer™, please ensure thatThe switched power outlet must be outside the refrigerator drawer cavity so that it is accessible afterinstallation.The switched power outlet must be located outside the cavity, within 55” (1400 mm) from theCoolDrawer™ cavity if situated on the left-hand side of the cavity and within 33 1/2” (850 mm) if situated on the right-hand side of the cavity. The services hole in the refrigerator cavity needs to be large enough for the power supply plug to fit through.

PARTS SUPPLIED4

5 CAVITY PREPARATION

WARNING!Tipping hazard

Do not operate this apppliance until it has been securely anchored inside thecabinetry. The cabinet must be securely anchored to the floor.

Failure to use caution could result in injury or cuts.

Installation trims (2)

Installation brackets (left-hand and right-hand side) (2)

Outlet duct (1)Trim brackets (4) Drawer Panel attachment hooks (3)

Power cord (1)

Note: Services can be located

either side of CoolDrawer™.

Benchtop

Pane

l

Phillips 5/8” (16 mm) wood screw (6)

Pan Head5/8” (16 mm)screw (12)

Pan Head5/8” (16 mm) screw (2)

Phillips 5/8” (16 mm ) wood screws (6)

2 PRODUCT DIMENSIONS

Product dimensions (inches [mm])

CoolD

rawer™

RB36S RB90S

A overall height of product (inc. installation brackets) 25 3/16” (640)

B overall width of product 33 11/16” (855)

C overall depth of product (excl. drawer panel; inc. power cord) 21 15/16” (557)

D depth of drawer (open) (excl. handle) 20 1/2” (520)

Installation diagrams for illustration purposes only

A

DH

Cabinetry dimensions (inches [mm]) C

oolDraw

er™RB36S RB90S

A overall width of cabinetry frame 35 1/2” (900)

B minimum inside width of cabinetry frame 34” (864)

C internal height of cabinetry to top of spacer block 25 3/8” (644)

D internal height of cabinetry*(to allow for product and outlet duct height)

min. 26 1/4” (665)max. 30 1/16” (764)

E minimum height of toe kick 3” (75)

F minimum depth** of toe kick 1 5/8” (40)

G minimum distance from front of cabinetry to rear wall 22 1/16” (560)

H width of spacer blocks 1 15/16” (50)*Minimum internal height of cabinetry can be 25 3/8” (644 mm) if outlet duct is not used.

**All depth measurements are taken from the front face of the cabinetry frame (not drawer panel)

Minimum clearances (inches [mm])

1/2” (13 mm)

1/16” (2 mm)

E

BC

D

G

F

F

C

G

6 INTEGRATED PANEL PREPARATION

AB

3 CABINETRY DIMENSIONS

An internal shelf can be used as an alternative to spacer blocks toposition the product at the correct height. In this case additional cutouts will be required. Refer to Step 7.

Installation diagrams for illustration purposes only

Drawer Panel

5/8 - 3/16” (16-20 mm)

False Panel35 1/4” (896 mm)

height of False Panel

3/16” (4 mm)

D height of Drawer

Panel

Benchtop

Dra

wer

pan

elFa

lse

pan

el

A

D

E

C

B

Integrated Panel material

5/8 - 13/16” (16 - 20 mm) panel thickness (3/4” [18 mm] recommended). Maximum weight of 15.5 lb (7 kg).Adequately sealed to withstand moisture (122OF/50OC @ 80% RH).

Height of Drawer Panel

The following information is required to correctly define your drawer panel height:

Dimension Data SourceA Clearance between top of Drawer panel and underside Your kitchen designer

of benchtopB Height between underside of cabinetry ceiling Your kitchen designer

and underside of benchtop C Internal height of cabinetry to top of spacer block 25 3/8” (644 mm)D Drawer panel height Calculated from A, B, C & EE Bottom face of Drawer panel to top of spacer block Your kitchen designer

(to ensure that bottom cover of product is not exposed) (Min. 6 1/16” [154 mm])(Max. 7 1/4” [184 mm])

To calculate D complete the following equation:

D = C + B - A - E

i.e. For the F&P prefinished panel:18 3/4” (476 mm) = 25 3/8” (644 mm) + 11/16” (18 mm) - 1/16” (2 mm) - 7 1/4” (184 mm)

Height of the False Panel

Determine the height of the false panel according to your individual kitchen cabinetry requirements maintaining a 3/16” (4 mm) gap between panels.

F&P prefinish panel width is 35 1/4” (896 mm) assuming a 1/16” (2 mm) clearance either side of panelheight (D) is 18 3/4” (476 mm).Note B must be min. 5/8” (16 mm) to ensure adequate clearance to benchtop.

SIDE VIEW

max. 33 1/2” (850 mm)

min. 21” (535 mm)

min. 5” (130 mm)

min. 21” (535 mm)

min. 5” (130 mm)

min. ø 1 15/16” (50 mm)

max. 3/4” 20 mm

Shows cutout if cabinetry depth at minimum 21 5/8” (550 mm)

Installation diagrams for illustration purposes only

COOLDRAWER™ MULTI-TEMPERATURE DRAWER

INSTALLATION INSTRUCTIONS

RB36S & RB90S models FRAMELESS CABINETRY

Page 4: COOLDRAWER™ MULTI-TEMPERATURE DRAWER · Drawer Panel Benchtop Drawer panel False panel A D E C B Integrated Panel material 5 /8 - 13 16” (16 - 20 mm) panel thickness (3/4” [18

Important!Disconnect power to surrounding appliances before preparing cavity.

Recommended to allow the vertical removal of the refrigerator bins.

WARNING!Electrical shock hazard

Disconnect product from main power supply before installing appliance.

Failure to do so may result in electrical shock or death

Important safety precautions! Installation of the CoolDrawer™ requires competent mechanical and electrical skills.Be sure to leave these Instructions with the Customer.Installation must comply with your local building and electricity regulations.At the completion of the CoolDrawer™ installation, the Installer must perform the Final Checklist.Remove all packaging materials supplied with the CoolDrawer™.The CoolDrawer™ is manufactured for indoor use only.

Important! SAVE THESE INSTRUCTIONSThe models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our website fisherpaykel.com or contact your local Fisher & Paykel dealer.

SAFETY AND WARNINGS

WARNING!Cut hazard

Take care - panel edges are sharp.

Failure to use caution could result in injury or cuts.

1

The CoolDrawer™ MUST be installed to allow for future removal from the enclosure if service is required. Do not seal the CoolDrawer™ into the cabinetry with silicone or glue. Doing so will make future servicing difficult. Fisher & Paykel will not be liable for any costs associated with removing or replacing a sealed-in product, nor for repairing any damage that may be incurred by doing this. Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to thepower supply cord.Failure to install the CoolDrawer™ correctly will invalidate any warranty or liability claims.If the power supply cord is damaged, it must be replaced. Parts are available from your AuthorisedFisher & Paykel dealer.This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capacities, or lack of experience and knowledge unless they are supervised or given instruction concerning use of the appliance. Cabinetry must be sufficiently robust to support a combined product and food load of 220 lb (100 kg).Bearers may be required to support the internal shelf.

Before you install the CoolDrawer™, please ensure thatThe switched power outlet must be outside the refrigerator drawer cavity so that it is accessible afterinstallation.The switched power outlet must be located outside the cavity, within 55” (1400 mm) from theCoolDrawer™ cavity if situated on the left-hand side of the cavity and within 33 1/2” (850 mm) if situated on the right-hand side of the cavity. The services hole in the refrigerator cavity needs to be large enough for the power supply plug to fit through.

PARTS SUPPLIED4

5 CAVITY PREPARATION

WARNING!Tipping hazard

Do not operate this apppliance until it has been securely anchored inside thecabinetry. The cabinet must be securely anchored to the floor.

Failure to use caution could result in injury or cuts.

Installationtrims (2)

Installation brackets (left-hand and right-hand side) (2)

Outlet duct (1)Trim brackets (4) Drawer Panel attachment hooks (3)

Power cord (1)

Note: Services can be located

either side of CoolDrawer™.

Benchtop

Pane

l

Phillips5/8” (16 mm) wood screw (6)

Pan Head5/8” (16 mm)screw (12)

Pan Head5/8” (16 mm) screw (2)

Phillips 5/8”(16 mm ) wood screws (6)

2 PRODUCT DIMENSIONS

Product dimensions (inches [mm])

CoolD

rawer™

RB36S RB90S

A overall height of product (inc. installation brackets) 25 3/16” (640)

B overall width of product 33 11/16” (855)

C overall depth of product (excl. drawer panel; inc. power cord) 21 15/16” (557)

D depth of drawer (open) (excl. handle) 20 1/2” (520)

Installation diagrams for illustration purposes only

A

DH

Cabinetry dimensions (inches [mm])

CoolD

rawer™

RB36S RB90S

A overall width of cabinetry frame 35 1/2” (900)

B minimum inside width of cabinetry frame 34” (864)

C internal height of cabinetry to top of spacer block 25 3/8” (644)

D internal height of cabinetry*(to allow for product and outlet duct height)

min. 26 1/4” (665)max. 30 1/16” (764)

E minimum height of toe kick 3” (75)

F minimum depth** of toe kick 1 5/8” (40)

G minimum distance from front of cabinetry to rear wall 22 1/16” (560)

H width of spacer blocks 1 15/16” (50)*Minimum internal height of cabinetry can be 25 3/8” (644 mm) if outlet duct is not used.

**All depth measurements are taken from the front face of the cabinetry frame (not drawer panel)

Minimum clearances (inches [mm])

1/2” (13 mm)

1/16” (2 mm)

E

BC

D

G

F

F

C

G

6 INTEGRATED PANEL PREPARATION

AB

3 CABINETRY DIMENSIONS

An internal shelf can be used as an alternative to spacer blocks toposition the product at the correct height. In this case additional cutouts will be required. Refer to Step 7.

Installation diagrams for illustration purposes only

Drawer Panel

5/8 - 3/16” (16-20 mm)

False Panel35 1/4” (896 mm)

height of False Panel

3/16” (4 mm)

D height of Drawer

Panel

Benchtop

Dra

wer

pan

elFa

lse

pan

el

A

D

E

C

B

Integrated Panel material

5/8 - 13/16” (16 - 20 mm) panel thickness (3/4” [18 mm] recommended). Maximum weight of 15.5 lb (7 kg).Adequately sealed to withstand moisture (122OF/50OC @ 80% RH).

Height of Drawer Panel

The following information is required to correctly define your drawer panel height:

Dimension Data SourceA Clearance between top of Drawer panel and underside Your kitchen designer of benchtopB Height between underside of cabinetry ceiling Your kitchen designer and underside of benchtop C Internal height of cabinetry to top of spacer block 25 3/8” (644 mm)D Drawer panel height Calculated from A, B, C & EE Bottom face of Drawer panel to top of spacer block Your kitchen designer

(to ensure that bottom cover of product is not exposed) (Min. 6 1/16” [154 mm]) (Max. 7 1/4” [184 mm])

To calculate D complete the following equation:

D = C + B - A - E

i.e. For the F&P prefinished panel:18 3/4” (476 mm) = 25 3/8” (644 mm) + 11/16” (18 mm) - 1/16” (2 mm) - 7 1/4” (184 mm)

Height of the False Panel

Determine the height of the false panel according to your individual kitchen cabinetry requirements maintaining a 3/16” (4 mm) gap between panels.

F&P prefinish panel width is 35 1/4” (896 mm) assuming a 1/16” (2 mm) clearance either side of panelheight (D) is 18 3/4” (476 mm). Note B must be min. 5/8” (16 mm) to ensure adequate clearance to benchtop.

SIDE VIEW

max. 33 1/2” (850 mm)

min. 21” (535 mm)

min. 5” (130 mm)

min. 21” (535 mm)

min. 5” (130 mm)

min. ø 1 15/16” (50 mm)

max. 3/4” 20 mm

Shows cutout if cabinetry depth atminimum 21 5/8” (550 mm)

Installation diagrams for illustration purposes only

COOLDRAWER™ MULTI-TEMPERATURE DRAWER

INSTALLATION INSTRUCTIONS

RB36S & RB90S models FRAMELESS CABINETRY

Page 5: COOLDRAWER™ MULTI-TEMPERATURE DRAWER · Drawer Panel Benchtop Drawer panel False panel A D E C B Integrated Panel material 5 /8 - 13 16” (16 - 20 mm) panel thickness (3/4” [18

3

1

2

1⁄16” (2 mm)

1

2

1

2

2

3

3 4 521

6 7

2

11

2 2

1

3

3 3

30 /” (764 mm)*

1 /” (50 mm)

11 /” (281 mm)

3” (76 mm)

2

3 4

1

/” (2 mm) /” (2 mm)

21

/” (9 mm)

x 3

35 ¼” (896 mm)

X

8

max. ø /” (16 mm)

4” (102 mm)

8 ½” (215 mm)

8 ½” (215 mm)

1 /” (40 mm)

1” (25 mm)

max. 33 /” (862 mm)min. 33 /” (860 mm)

1 /” (46 mm) 12 ¼” (311 mm) 12 ¼” (311 mm)

16 /” (414 mm

)

/” (18 mm)

/“ (2.5 mm)

/” (5 mm)

/ - /”

(16 - 20 mm)

/” (1 mm)

fisherpaykel.com 840510C FRAMELESS CABINETRY 07.18

Important!Ensure a minimum of 3 screws per side are used. The rear screws must always be used. Horizontal fixing is also optional.

If the cabinetry does not already have cutouts, ensure the modifications below are made.

Important!Ensure the power cord is clipped in place.

Important!Ensure you check basic operation and perform the final checklist.

Attach the false panel securely as recommended by the cabinetmaker.

Important!The false panel needs to be removable forservicing.

Secure using vertical or horizontal fixing

CREATE CUTOUTS IN FRAME7 LOCATE & SECURE INSTALL BRACKETS8

Important!Cut outlet duct to be flush with top of spacer blocks.

9 ATTACH OUTLET VENT DUCT 10 ATTACH POWER CORD & TRIM BRACKETS

Important!Note correct orientation of bracket.

14 SECURE PRODUCT TO CABINETRY 15 ATTACH TRIMS TO SIDES OF CABINETRY

16 ATTACH FALSE PANEL 17 CHECK OPERATION

Open drawer and secure product to cabinetry using four Trim brackets and screws.

18 FINAL CHECKLISTTO BE COMPLETED BY THE INSTALLER

Has all packaging been removed from the appliance?

Is the appliance securely fastened to the cabinetry?

Does the drawer slide freely and close properly?

Has the outlet duct been installed correctly?

Is the appliance level?

Are the panels securely attached?

Have the panels been properly aligned for correct operation and appearance? Are all clearances even?

Is there clearance between drawer and cabinetry frame?

Has the power cord been plugged into a properly earthed 3-prong outlet,which has been installed in accordance with all applicable electrical codes?

OPERATION:

Is the control panel lit?

Can you hear the compressor motor running?

When a hand is placed near the toe kick, can airflow be felt under front right-hand side of appliance?

Have you demonstrated the basic operation to the customer?

Installer’s name:

Installer’s signature:

Installation company:

Date of installation:

LEAVE THESE INSTRUCTIONS WITH THE CUSTOMER

*Only with cabinetry with internal shelf

13 ATTACH DRAWER PANEL TO FRONT OF DRAWER

Important!Do not screw in trimbrackets at this stage.

Hook drawer panel ontodrawer front channel

Close the drawer andcheck vertical clearances

Remove the panel and adjust the TOPattachment hooks as necesary

Replace panel ondrawer and confirm vertical clearances

Slide panel to achieve horizontal clearances

Open drawer and clamppanel onto drawer by tightening the BOTTOMattachment hook

Close the drawer and ensure it is flush with adjacent cabinetry. If not, the product may have to be pulled back or forward.

Important!Be careful not to damage power supply cord when pushing product into cavity.

Attach handle as necessary. Ensure all screws are flush with panel surface.

X = 7 5/8” (194 mm) – E, where E is Bottom face of Drawer Panel to top of spacer block, see . 6

Ensure there is clearancebetween panel and cabinetrywhen drawer is fully closed

Page 6: COOLDRAWER™ MULTI-TEMPERATURE DRAWER · Drawer Panel Benchtop Drawer panel False panel A D E C B Integrated Panel material 5 /8 - 13 16” (16 - 20 mm) panel thickness (3/4” [18

3

1

2

1⁄16” (2 mm)

1

2

1

2

2

3

3 4 521

6 7

2

11

2 2

1

3

3 3

30 /” (764 mm)*

1 /” (50 mm)

11 /” (281 mm)

3” (76 mm)

2

3 4

1

/” (2 mm) /” (2 mm)

21

/” (9 mm)

x 3

35 ¼” (896 mm)

X

8

max. ø /” (16 mm)

4” (102 mm)

8 ½” (215 mm)

8 ½” (215 mm)

1 /” (40 mm)

1” (25 mm)

max. 33 /” (862 mm)min. 33 /” (860 mm)

1 /” (46 mm) 12 ¼” (311 mm) 12 ¼” (311 mm)

16 /” (414 mm

)

/” (18 mm)

/“ (2.5 mm)

/” (5 mm)

/ - /”

(16 - 20 mm)

/” (1 mm)

fisherpaykel.com 840510C FRAMELESS CABINETRY 07.18

Important!Ensure a minimum of 3 screwsper side are used. The rear screws must always be used. Horizontal fixing is also optional.

If the cabinetry does not already have cutouts, ensure the modifications below are made.

Important!Ensure the power cord is clipped in place.

Important!Ensure you check basic operation and perform the final checklist.

Attach the false panel securely as recommended by the cabinetmaker.

Important!The false panel needs to be removable forservicing.

Secure using vertical or horizontal fixing

CREATE CUTOUTS IN FRAME7 LOCATE & SECURE INSTALL BRACKETS8

Important!Cut outlet duct to be flush with top of spacer blocks.

9 ATTACH OUTLET VENT DUCT 10 ATTACH POWER CORD & TRIM BRACKETS

Important!Note correct orientation of bracket.

14 SECURE PRODUCT TO CABINETRY 15 ATTACH TRIMS TO SIDES OF CABINETRY

16 ATTACH FALSE PANEL 17 CHECK OPERATION

Open drawer and secure product to cabinetry using four Trim brackets and screws.

18 FINAL CHECKLISTTO BE COMPLETED BY THE INSTALLER

Has all packaging been removed from the appliance?

Is the appliance securely fastened to the cabinetry?

Does the drawer slide freely and close properly?

Has the outlet duct been installed correctly?

Is the appliance level?

Are the panels securely attached?

Have the panels been properly aligned for correct operation and appearance? Are all clearances even?

Is there clearance between drawer and cabinetry frame?

Has the power cord been plugged into a properly earthed 3-prong outlet,which has been installed in accordance with all applicable electrical codes?

OPERATION:

Is the control panel lit?

Can you hear the compressor motor running?

When a hand is placed near the toe kick, can airflow be felt under front right-hand side of appliance?

Have you demonstrated the basic operation to the customer?

Installer’s name:

Installer’s signature:

Installation company:

Date of installation:

LEAVE THESE INSTRUCTIONS WITH THE CUSTOMER

*Only with cabinetry with internal shelf

13 ATTACH DRAWER PANEL TO FRONT OF DRAWER

Important!Do not screw in trim brackets at this stage.

Hook drawer panel onto drawer front channel

Close the drawer and check vertical clearances

Remove the panel and adjust the TOP attachment hooks as necesary

Replace panel on drawer and confirm vertical clearances

Slide panel to achieve horizontal clearances

Open drawer and clamp panel onto drawer by tightening the BOTTOM attachment hook

Close the drawer and ensure it is flush with adjacent cabinetry. If not, the product may have to be pulled back or forward.

Important!Be careful not to damage power supply cord when pushing product into cavity.

11 MOVE PRODUCT INTO CAVITY 12 FIT DRAWER PANEL ATTACHMENT HOOKS

Attach handle as necessary. Ensure all screws are flush with panel surface.

X = 7 5/8” (194 mm) – E, where E is Bottom face of Drawer Panel to top of spacer block, see . 6

Ensure there is clearancebetween panel and cabinetrywhen drawer is fully closed

Page 7: COOLDRAWER™ MULTI-TEMPERATURE DRAWER · Drawer Panel Benchtop Drawer panel False panel A D E C B Integrated Panel material 5 /8 - 13 16” (16 - 20 mm) panel thickness (3/4” [18

3

1

2

1⁄16” (2 mm)

1

2

1

2

2

3

3 4 521

6 7

2

11

2 2

1

3

3 3

30 /” (764 mm)*

1 /” (50 mm)

11 /” (281 mm)

3” (76 mm)

2

3 4

1

/” (2 mm) /” (2 mm)

21

/” (9 mm)

x 3

35 ¼” (896 mm)

X

8

max. ø /” (16 mm)

4” (102 mm)

8 ½” (215 mm)

8 ½” (215 mm)

1 /” (40 mm)

1” (25 mm)

max. 33 /” (862 mm)min. 33 /” (860 mm)

1 /” (46 mm) 12 ¼” (311 mm) 12 ¼” (311 mm)

16 /” (414 mm

)

/” (18 mm)

/“ (2.5 mm)

/” (5 mm)

/ - /”

(16 - 20 mm)

/” (1 mm)

fisherpaykel.com 840510C FRAMELESS CABINETRY 07.18

Important!Ensure a minimum of 3 screwsper side are used. The rear screws must always be used. Horizontal fixing is also optional.

If the cabinetry does not already have cutouts, ensure the modifications below are made.

Important!Ensure the power cord is clipped in place.

Important!Ensure you check basic operation and perform the final checklist.

Attach the false panel securely as recommended by the cabinet maker.

Important!The false panel needs to be removable for servicing.

Secure using vertical or horizontal fixing

CREATE CUTOUTS IN FRAME7 LOCATE & SECURE INSTALL BRACKETS8

Important!Cut outlet duct to be flush with top of spacer blocks.

9 ATTACH OUTLET VENT DUCT 10 ATTACH POWER CORD & TRIM BRACKETS

Important!Note correct orientation of bracket.

14 SECURE PRODUCT TO CABINETRY 15 ATTACH TRIMS TO SIDES OF CABINETRY

16 ATTACH FALSE PANEL 17 CHECK OPERATION

Open drawer and secure product to cabinetry using four Trim brackets and screws.

18 FINAL CHECKLISTTO BE COMPLETED BY THE INSTALLER

Has all packaging been removed from the appliance?

Is the appliance securely fastened to the cabinetry?

Does the drawer slide freely and close properly?

Has the outlet duct been installed correctly?

Is the appliance level?

Are the panels securely attached?

Have the panels been properly aligned for correct operation and appearance? Are all clearances even?

Is there clearance between drawer and cabinetry frame?

Has the power cord been plugged into a properly earthed 3-prong outlet,which has been installed in accordance with all applicable electrical codes?

OPERATION:

Is the control panel lit?

Can you hear the compressor motor running?

When a hand is placed near the toe kick, can airflow be felt under front right-hand side of appliance?

Have you demonstrated the basic operation to the customer?

Installer’s name:

Installer’s signature:

Installation company:

Date of installation:

LEAVE THESE INSTRUCTIONS WITH THE CUSTOMER

*Only with cabinetry with internal shelf

13 ATTACH DRAWER PANEL TO FRONT OF DRAWER

Important!Do not screw in trimbrackets at this stage.

Hook drawer panel ontodrawer front channel

Close the drawer andcheck vertical clearances

Remove the panel and adjust the TOPattachment hooks as necesary

Replace panel ondrawer and confirm vertical clearances

Slide panel to achieve horizontal clearances

Open drawer and clamppanel onto drawer by tightening the BOTTOMattachment hook

Close the drawer and ensure it is flush with adjacent cabinetry. If not, the product may have to be pulled back or forward.

Important!Be careful not to damage power supply cord when pushing product into cavity.

11 MOVE PRODUCT INTO CAVITY 12 FIT DRAWER PANEL ATTACHMENT HOOKS

Attach handle as necessary. Ensure all screws are flush with panel surface.

X = 7 5/8” (194 mm) – E, where E is Bottom face of Drawer Panel to top of spacer block, see . 6

Ensure there is clearancebetween panel and cabinetrywhen drawer is fully closed

Page 8: COOLDRAWER™ MULTI-TEMPERATURE DRAWER · Drawer Panel Benchtop Drawer panel False panel A D E C B Integrated Panel material 5 /8 - 13 16” (16 - 20 mm) panel thickness (3/4” [18

3

1

2

1⁄16” (2 mm)

1

2

1

2

2

3

3 4 521

6 7

2

11

2 2

1

3

3 3

30 /” (764 mm)*

1 /” (50 mm)

11 /” (281 mm)

3” (76 mm)

2

3 4

1

/” (2 mm) /” (2 mm)

21

/” (9 mm)

x 3

35 ¼” (896 mm)

X

8

max. ø /” (16 mm)

4” (102 mm)

8 ½” (215 mm)

8 ½” (215 mm)

1 /” (40 mm)

1” (25 mm)

max. 33 /” (862 mm)min. 33 /” (860 mm)

1 /” (46 mm) 12 ¼” (311 mm) 12 ¼” (311 mm)

16 /” (414 mm

)

/” (18 mm)

/“ (2.5 mm)

/” (5 mm)

/ - /”

(16 - 20 mm)

/” (1 mm)

fisherpaykel.com 840510C FRAMELESS CABINETRY 07.18

Important!Ensure a minimum of 3 screws per side are used. The rear screws must always be used. Horizontal fixing is also optional.

If the cabinetry does not already have cutouts, ensure the modifications below are made.

Important!Ensure the power cord is clipped in place.

Important!Ensure you check basic operation and perform the final checklist.

Attach the false panel securely as recommended by the cabinet maker.

Important!The false panel needs to be removable for servicing.

Secure using vertical or horizontal fixing

CREATE CUTOUTS IN FRAME7 LOCATE & SECURE INSTALL BRACKETS8

Important!Cut outlet duct to be flush with top of spacer blocks.

9 ATTACH OUTLET VENT DUCT 10 ATTACH POWER CORD & TRIM BRACKETS

Important!Note correct orientation of bracket.

14 SECURE PRODUCT TO CABINETRY 15 ATTACH TRIMS TO SIDES OF CABINETRY

16 ATTACH FALSE PANEL 17 CHECK OPERATION

Open drawer and secure product to cabinetry using four Trim brackets and screws.

18 FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER

Has all packaging been removed from the appliance?

Is the appliance securely fastened to the cabinetry? Does the drawer slide freely and close properly?

Has the outlet duct been installed correctly?

Is the appliance level?

Are the panels securely attached?

Have the panels been properly aligned for correct operation and appearance? Are all clearances even?

Is there clearance between drawer and cabinetry frame?

Has the power cord been plugged into a properly earthed 3-prong outlet, which has been installed in accordance with all applicable electrical codes? OPERATION:

Is the control panel lit? Can you hear the compressor motor running? When a hand is placed near the toe kick, can airflow be felt under front right-hand side of appliance?

Have you demonstrated the basic operation to the customer?

Installer’s name:

Installer’s signature:

Installation company:

Date of installation:

LEAVE THESE INSTRUCTIONS WITH THE CUSTOMER

*Only with cabinetry with internal shelf

13 ATTACH DRAWER PANEL TO FRONT OF DRAWER

Important!Do not screw in trim brackets at this stage.

Hook drawer panel onto drawer front channel

Close the drawer and check vertical clearances

Remove the panel and adjust the TOP attachment hooks as necesary

Replace panel on drawer and confirm vertical clearances

Slide panel to achieve horizontal clearances

Open drawer and clamp panel onto drawer by tightening the BOTTOM attachment hook

Close the drawer and ensure it is flush with adjacent cabinetry. If not, the product may have to be pulled back or forward.

Important!Be careful not to damage power supply cord when pushing product into cavity.

11 MOVE PRODUCT INTO CAVITY 12 FIT DRAWER PANEL ATTACHMENT HOOKS

Attach handle as necessary. Ensure all screws are flush with panel surface.

X = 7 5/8” (194 mm) – E, where E is Bottom face of Drawer Panel to top of spacer block, see . 6

Ensure there is clearancebetween panel and cabinetrywhen drawer is fully closed