cree racine engineering services testing …...35 4421 4422 4437 4445 4466 4478 4501 4523 4544 4553...

13
NVLAP Lab Code 500089-0 Test Report Number: PL09298-001A RESTL-R010 Rev G This report contains data that are not covered by the NVLAP accreditation. This report also contains integrating sphere data that was produced under subcontract by Cree Engineering Services Testing Laboratory NVLAP Code 500077-0. Cree, Inc | 9201 Washington Avenue | Racine, WI 53406 Page 1 of 13 Report Number: PL09298-001A Model: ARE-EHO-5M-xx-12-E-UL-xx-1000-xxxx-40K Date: 09/15/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Tammy Lehrmann Cree, Inc. 9201 Washington Avenue Racine, WI 53406 Prepared By: Approved By: Linjie Li, LC, Test Engineer Christopher McLaurin, Photometric Specialist

Upload: others

Post on 10-Jul-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Cree Racine Engineering Services Testing …...35 4421 4422 4437 4445 4466 4478 4501 4523 4544 4553 4548 4546 4526 4510 4489 4465 4466 4455 4454 37.5 4465 4470 4491 4515 4552 4580

NVLAP Lab Code 500089-0

Test Report Number: PL09298-001A RESTL-R010 Rev G

This report contains data that are not covered by the NVLAP accreditation. This report also contains integrating sphere data that was produced under subcontract by Cree Engineering Services Testing Laboratory – NVLAP Code 500077-0.

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 1 of 13

Report Number: PL09298-001A

Model: ARE-EHO-5M-xx-12-E-UL-xx-1000-xxxx-40K

Date: 09/15/2016

Cree Racine Engineering Services Testing Laboratory

(RESTL) Photometric Testing and Evaluation

Report

Prepared For:

Tammy Lehrmann

Cree, Inc.

9201 Washington Avenue

Racine, WI 53406

Prepared By: Approved By:

Linjie Li, LC, Test Engineer Christopher McLaurin, Photometric Specialist

Page 2: Cree Racine Engineering Services Testing …...35 4421 4422 4437 4445 4466 4478 4501 4523 4544 4553 4548 4546 4526 4510 4489 4465 4466 4455 4454 37.5 4465 4470 4491 4515 4552 4580

NVLAP Lab Code 500089-0

Test Report Number: PL09298-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 2 of 13

Product Information

Manufacturer Cree, Inc.

Model Number (SKU) ARE-EHO-5M-xx-12-E-UL-xx-1000-xxxx-40K

Serial Number PL09298-001

LED Type XP-G2

Product Description

Brown metal housing with two end caps. Four heat sinks each with one LED board and brown metal trim plate. One clear plastic optical lens below each LED.

Driver Information (Where Applicable)

2x Cree LE098X01

Length Width Height

43.0” 17.0” 5.0”

Sample

The following sample was submitted for evaluation

Page 3: Cree Racine Engineering Services Testing …...35 4421 4422 4437 4445 4466 4478 4501 4523 4544 4553 4548 4546 4526 4510 4489 4465 4466 4455 4454 37.5 4465 4470 4491 4515 4552 4580

NVLAP Lab Code 500089-0

Test Report Number: PL09298-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 3 of 13

Key Photometric Data Sphere Output Goniophotometer

Luminous Flux 36970.0 36005.3 lm

Efficacy 87.17 84.53 lm/W

Correlated Color Temperature (CCT) 3944 K

Color Rendering Index (CRI) 74

R9 -14

Duv -0.000368

S/P Ratio* 1.50

Sphere Goniophotometer

Electrical Measurements 120V 277V 120V 277V

Input Wattage 424.10 411.70 425.95 412.40 W

Input Current 3.55 1.53 3.56 1.53 A

Input Voltage 120.02 276.98 120.09 276.93 V

Power Factor 0.996 0.971 0.997 0.974

Off-State Power 0 0 0 0 W

Total Harmonic Distortion (Voltage) 0.19 0.10 0.11 0.09 %

Total Harmonic Distortion (Amperage) 6.26 10.70 5.82 9.55 %

Note: All photometric measurements taken at 120VAC.

Luminous Intensity Distribution Goniophotometer

Max Candela 12,040.5 Cd

Angle of Max Candela (Horizontal) 0 ˚

Angle of Max Candela (Vertical) 65 ˚

Key Test Parameters Sphere Output Goniophotometer

Stabilization Time 90 57 min

Total Operating Time (Stabilization + Test) 90 77 min

Ambient Temperature 25.8 24.9 ˚C

Page 4: Cree Racine Engineering Services Testing …...35 4421 4422 4437 4445 4466 4478 4501 4523 4544 4553 4548 4546 4526 4510 4489 4465 4466 4455 4454 37.5 4465 4470 4491 4515 4552 4580

NVLAP Lab Code 500089-0

Test Report Number: PL09298-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 4 of 13

Chromaticity Coordinates**

x y u v u’ v’ Duv

0.3826 0.3773 0.2263 0.3348 0.2263 0.5022 -0.000368

Color Rendering Index Details**

Ra R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14

74 72 79 83 75 72 70 81 58 -14 49 72 48 73 90

Chromaticity Diagram**

Page 5: Cree Racine Engineering Services Testing …...35 4421 4422 4437 4445 4466 4478 4501 4523 4544 4553 4548 4546 4526 4510 4489 4465 4466 4455 4454 37.5 4465 4470 4491 4515 4552 4580

NVLAP Lab Code 500089-0

Test Report Number: PL09298-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 5 of 13

Spectral Distribution**

λ(nm) W/nm λ(nm) W/nm λ(nm) W/nm

360 0.001778 530 0.479934 700 0.085585

370 0.001377 540 0.525955 710 0.064478

380 0.000979 550 0.557657 720 0.048907

390 0.001433 560 0.588301 730 0.036437

400 0.003619 570 0.616406 740 0.027318

410 0.020432 580 0.638454 750 0.020609

420 0.105487 590 0.642479 760 0.015536

430 0.328546 600 0.622678 770 0.011890

440 0.603448 610 0.582195 780 0.009118

450 0.568438 620 0.519430 790 0.006976

460 0.244507 630 0.450064 800 0.005608

470 0.123003 640 0.377911 810 0.004297

480 0.084280 650 0.307966 820 0.003382

490 0.104263 660 0.246454 830 0.002637

500 0.187153 670 0.191444

510 0.304242 680 0.147663

520 0.408306 690 0.112718

Dominant Wavelength** 579 nm

Peak Wavelength** 445 nm

Spectral Power Distribution (W/nm) **

Page 6: Cree Racine Engineering Services Testing …...35 4421 4422 4437 4445 4466 4478 4501 4523 4544 4553 4548 4546 4526 4510 4489 4465 4466 4455 4454 37.5 4465 4470 4491 4515 4552 4580

NVLAP Lab Code 500089-0

Test Report Number: PL09298-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 6 of 13

Zonal Lumen Summary

Zone Lumens % of Total Zone Lumens % of Total

0-5 55.1 0.2% 90-95 0.0 0.0%

5-10 166.5 0.5% 95-100 0.0 0.0%

10-15 295.8 0.8% 100-105 0.0 0.0%

15-20 480.1 1.3% 105-110 0.0 0.0%

20-25 729.4 2.0% 110-115 0.0 0.0%

25-30 1011.4 2.8% 115-120 0.0 0.0%

30-35 1284.6 3.6% 120-125 0.0 0.0%

35-40 1530.2 4.2% 125-130 0.0 0.0%

40-45 1874.8 5.2% 130-135 0.0 0.0%

45-50 2572.7 7.1% 135-140 0.0 0.0%

50-55 3548.6 9.9% 140-145 0.0 0.0%

55-60 4232.0 11.8% 145-150 0.0 0.0%

60-65 4892.9 13.6% 150-155 0.0 0.0%

65-70 5298.6 14.7% 155-160 0.0 0.0%

70-75 4370.0 12.1% 160-165 0.0 0.0%

75-80 2589.0 7.2% 165-170 0.0 0.0%

80-85 952.7 2.6% 170-175 0.0 0.0%

85-90 121.1 0.3% 175-180 0.0 0.0%

Total 36005.3 lm 100%

Page 7: Cree Racine Engineering Services Testing …...35 4421 4422 4437 4445 4466 4478 4501 4523 4544 4553 4548 4546 4526 4510 4489 4465 4466 4455 4454 37.5 4465 4470 4491 4515 4552 4580

NVLAP Lab Code 500089-0

Test Report Number: PL09298-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 7 of 13

Candela Plot Illuminance Plot

Roadway Utilization Roadway Summary Lumens % Lamp

Distribution Type VS

Downward Street Side 18,000.6 50.0%

Downward House Side 18,000.6 50.0%

Downward Total 36,001.2 100.0%

Upward Street Side 0.0 0.0%

Upward House Side 0.0 0.0%

Upward Total 0.0 0.0%

Total Lumens 36,001.2 100.0%

Page 8: Cree Racine Engineering Services Testing …...35 4421 4422 4437 4445 4466 4478 4501 4523 4544 4553 4548 4546 4526 4510 4489 4465 4466 4455 4454 37.5 4465 4470 4491 4515 4552 4580

NVLAP Lab Code 500089-0

Test Report Number: PL09298-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 8 of 13

Luminaire Classification System

Page 9: Cree Racine Engineering Services Testing …...35 4421 4422 4437 4445 4466 4478 4501 4523 4544 4553 4548 4546 4526 4510 4489 4465 4466 4455 4454 37.5 4465 4470 4491 4515 4552 4580

NVLAP Lab Code 500089-0

Test Report Number: PL09298-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 9 of 13

Candela Tabulations

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

0 2307 2307 2307 2307 2307 2307 2307 2307 2307 2307 2307 2307 2307 2307 2307 2307 2307 2307 2307

2.5 2306 2302 2302 2306 2306 2306 2307 2310 2305 2305 2305 2308 2304 2307 2305 2302 2303 2303 2298

5 2301 2299 2299 2303 2303 2304 2305 2308 2304 2304 2304 2308 2304 2307 2305 2302 2303 2303 2298

7.5 2307 2307 2308 2312 2313 2314 2316 2320 2317 2318 2318 2323 2319 2321 2319 2317 2318 2318 2313

10 2338 2343 2344 2350 2352 2355 2359 2364 2362 2365 2366 2371 2368 2369 2368 2364 2365 2364 2360

12.5 2422 2432 2436 2443 2447 2452 2459 2467 2466 2473 2474 2482 2479 2484 2483 2478 2481 2481 2475

15 2578 2595 2600 2608 2611 2617 2627 2636 2637 2645 2648 2660 2660 2671 2673 2676 2684 2689 2684

17.5 2823 2845 2846 2849 2848 2851 2857 2864 2865 2874 2880 2896 2904 2920 2935 2948 2962 2965 2967

20 3125 3145 3140 3136 3135 3127 3128 3131 3132 3139 3149 3173 3189 3210 3232 3243 3261 3265 3270

22.5 3435 3457 3452 3445 3437 3425 3415 3413 3410 3419 3431 3462 3484 3511 3531 3539 3554 3561 3558

25 3743 3754 3751 3743 3728 3709 3698 3691 3685 3695 3709 3740 3760 3791 3806 3814 3827 3832 3826

27.5 4003 4002 4002 3994 3980 3964 3955 3949 3947 3956 3968 3994 4009 4031 4040 4044 4058 4057 4057

30 4202 4195 4198 4195 4195 4181 4180 4178 4181 4189 4197 4216 4223 4232 4236 4228 4238 4233 4234

32.5 4338 4334 4341 4342 4353 4351 4359 4368 4378 4386 4388 4399 4394 4391 4382 4366 4371 4364 4363

35 4421 4422 4437 4445 4466 4478 4501 4523 4544 4553 4548 4546 4526 4510 4489 4465 4466 4455 4454

37.5 4465 4470 4491 4515 4552 4580 4613 4642 4668 4677 4667 4657 4632 4609 4579 4542 4533 4516 4513

40 4516 4522 4543 4567 4611 4659 4732 4806 4872 4897 4866 4812 4744 4691 4647 4610 4605 4590 4587

42.5 4562 4585 4636 4722 4857 5009 5177 5323 5436 5475 5423 5321 5174 5019 4884 4765 4714 4676 4670

45 5082 5094 5168 5271 5410 5569 5749 5918 6053 6097 6038 5933 5767 5605 5463 5327 5239 5173 5143

47.5 5646 5705 5782 5916 6088 6313 6554 6777 6947 7011 6926 6787 6564 6362 6168 6012 5917 5857 5839

50 6556 6596 6701 6872 7061 7305 7543 7755 7918 7964 7890 7756 7548 7357 7142 6955 6837 6734 6714

52.5 7795 7805 7887 8005 8139 8277 8404 8518 8622 8639 8588 8530 8412 8311 8183 8047 7977 7900 7883

55 8847 8859 8873 8883 8891 8881 8868 8855 8873 8862 8852 8886 8897 8925 8937 8924 8939 8931 8924

57.5 9377 9395 9339 9253 9141 9032 8935 8882 8886 8879 8888 8953 9019 9130 9235 9323 9429 9484 9506

60 9916 9961 9836 9656 9439 9249 9095 9007 8995 8992 8994 9070 9158 9308 9479 9648 9816 9913 9960

62.5 11355 11197 11014 10721 10326 9954 9627 9404 9314 9279 9292 9412 9573 9798 10030 10217 10409 10508 10556

65 12040 11951 11865 11689 11365 10946 10485 10095 9875 9776 9786 9943 10104 10300 10511 10660 10805 10874 10928

67.5 11142 11195 11234 11265 11261 11172 10966 10703 10494 10343 10275 10285 10291 10312 10381 10335 10350 10314 10338

70 9889 9956 10026 10112 10221 10328 10404 10455 10478 10361 10096 9905 9679 9422 9245 9069 9013 8964 8963

72.5 8480 8552 8636 8734 8848 8954 9035 9184 9262 9067 8794 8478 8163 7924 7783 7656 7573 7512 7505

75 6822 6903 6979 7078 7204 7285 7330 7334 7248 6993 6830 6695 6531 6321 6178 6023 5908 5806 5791

77.5 4933 5028 5097 5206 5351 5436 5370 5222 5101 5043 4904 4766 4611 4449 4303 4164 4071 3983 3960

80 3238 3285 3316 3416 3551 3522 3351 3295 3220 3094 2985 2889 2809 2733 2671 2611 2581 2525 2513

82.5 1880 1921 1932 1972 1959 1898 1835 1642 1541 1535 1605 1591 1544 1506 1482 1456 1436 1427 1428

85 924 944 933 862 852 772 721 564 525 527 631 626 580 538 519 505 488 492 500

87.5 183 194 191 185 182 175 132 74 66 62 84 101 93 86 81 78 77 80 80

90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Page 10: Cree Racine Engineering Services Testing …...35 4421 4422 4437 4445 4466 4478 4501 4523 4544 4553 4548 4546 4526 4510 4489 4465 4466 4455 4454 37.5 4465 4470 4491 4515 4552 4580

NVLAP Lab Code 500089-0

Test Report Number: PL09298-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 10 of 13

Candela Tabulations (Continued)

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

92.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

97.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

100 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

102.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

105 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

107.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

110 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

112.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

115 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

117.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

120 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

122.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

125 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

127.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

130 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

132.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

135 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

137.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

140 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

142.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

145 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

147.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

150 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

152.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

155 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

157.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

160 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

162.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

165 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

167.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

170 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

172.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

175 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

177.5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

180 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Page 11: Cree Racine Engineering Services Testing …...35 4421 4422 4437 4445 4466 4478 4501 4523 4544 4553 4548 4546 4526 4510 4489 4465 4466 4455 4454 37.5 4465 4470 4491 4515 4552 4580

NVLAP Lab Code 500089-0

Test Report Number: PL09298-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 11 of 13

Integrating Sphere Equipment List

Description Manufacturer Model Serial Number

3M Sphere Labsphere CSTM-CSLMS-3M98-HDS 82456

CCD Array Spectrometer Otsuka MC-9801 98010165

Programmable AC Source Chroma 61603 616030000761

Single Channel Power Analyzer Xitron 2801 28011110008

Aux Lamp Power Supply Labsphere LPS-100-0833 1002104538

Goniophotometer Equipment List

Description Manufacturer Model Serial Number

AC Power Source Chroma 61602 616020002300

Type C Goniophotometer LSI / UL 6440T 6440PN2028

Spectroradiometer Gooch & Housego 770VIS/NIR 12415212

Power Meter Yokogawa WT210 91M945458

Test Methods Used:

Title Description

ANSI C82.77:2002 Harmonic Emission Limits- Related Power Quality Reqt’s for Lighting Equipment

CIE Pub. 13.3:1995 Method of Measuring and Specifying Color Rendering of Light Sources

CIE Pub. 15:2004 Colorimetry

IES LM-58:1994 Spectroradiometric Measurements

IES LM-65:2001 Single-Ended Compact Fluorescent Lamps – Life Test Performance

IES LM-79:2008 Electrical and Photometric Measurements of Solid-State Lighting Products

Reference Standard Used:

Equipment Description

3m Sphere Tungsten Halogen Omni-Directional 75W Calibration Lamp, Serial Number G141

Type C Goniophotometer and Spectrometer

Tungsten Halogen Omni-Directional 500W Calibration Lamp, Serial Numbers 13C069. 13C070, 13C071. For color calibration of spectrometer, 13C074.

Page 12: Cree Racine Engineering Services Testing …...35 4421 4422 4437 4445 4466 4478 4501 4523 4544 4553 4548 4546 4526 4510 4489 4465 4466 4455 4454 37.5 4465 4470 4491 4515 4552 4580

NVLAP Lab Code 500089-0

Test Report Number: PL09298-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 12 of 13

Disclaimers:

This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government.

The results contained in this report pertain only to the tested sample.

This report shall not be reproduced, except in full, without written approval of the RESTL.

*Items marked with a single asterisk are not covered by the NVLAP accreditation.

In the event that the recorded temperature is outside of 25 ± 1˚C, this is considered a non-standard condition.

** In the event that testing is subcontracted, test results in this report marked with the symbol **, or noted as

“Sphere” or “Integrating Sphere”, were performed by the subcontracted laboratory identified in the footer on the

first page of this report. Subcontracted testing is strictly integrating sphere based. All other tests are

performed using a Type C goniophotometer.

The integrating sphere information in the equipment list, report items marked with **, or results specifically

identified as “Sphere” or “Integrating Sphere”, are the actual equipment used, and test results produced, by the

subcontracted laboratory when subcontracting is indicated on the cover page.

Additional Comments:

The photos below are intended to show the orientation and fixturing/set-up of the units under test. These

are critical to understanding the results of the test given the sensitivity of many products and

measurement systems to orientation and set-up considerations, and also for reproducing the conditions of

the test.

Goniophotometer Integrating Sphere

Page 13: Cree Racine Engineering Services Testing …...35 4421 4422 4437 4445 4466 4478 4501 4523 4544 4553 4548 4546 4526 4510 4489 4465 4466 4455 4454 37.5 4465 4470 4491 4515 4552 4580

NVLAP Lab Code 500089-0

Test Report Number: PL09298-001A RESTL-R010 Rev G

C r e e , I n c | 9 2 0 1 W a s h i n g t o n A v e n u e | R a c i n e , W I 5 3 4 0 6

Page 13 of 13

Document Revision History:

Each subsequent revision of this report replaces the preceding report.

Date Rev DCN # Change at the time of this test By Approval

09/15/16 A DMS Origination L. Li C. McLaurin