c.r.i. submersible cables · standards conforming to pvc awg - ul 83, iec 60227, bs 6500, isi 694...

8

Upload: dangdiep

Post on 07-Oct-2018

230 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: C.R.I. SUBMERSIBLE CABLES · Standards conforming to PVC AWG - UL 83, IEC 60227, BS 6500, ISI 694 Rubber AWG - UL 83, IEC 60245, DIN VDE 0282, PART 810, BS 6007 & BS 6899 ARMOURED
Page 2: C.R.I. SUBMERSIBLE CABLES · Standards conforming to PVC AWG - UL 83, IEC 60227, BS 6500, ISI 694 Rubber AWG - UL 83, IEC 60245, DIN VDE 0282, PART 810, BS 6007 & BS 6899 ARMOURED

C .R . I . SUB MERS IB LE CA B LES 1

C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N

C . R . I . I S O N E A M O N G the few pioneers in the world to produce 100% stainless steel submersible

pumps. Having achieved a record production capacity of over 2 million

pumps per annum, today C.R.I. is rubbing its shoulders with the best brands

in the world, with advanced technology and safety standards as its hallmarks.

T H E B E G I N N I N G of C.R.I., way back in 1961, was a resolute attempt to produce a few irrigation

equipments using the limited facilities of an in-house foundry. Eventually the

founder's dream was coming true as the small production unit he started kept

growing rapidly. Now, after more than five eventful decades, it is an enormous,

widely reputed organization, which produces more than 2300 varieties of

perfectly engineered pumps and motors and sells its products in numerous

countries spread across 6 continents.

T H E I N F R A S T R U C T U R E of C.R.I. is pretty comprehensive with state-of-the-art machineries and

high potential in-house R&D recognised by the ministry of science and

technology, Govt. of India - all within its own covered area of 300,000 square

metres. The production environment is accredited with ISO 9001, ISO 14001

& OSHAS 18001 certifications and the products are CE, UR/UL, TSE & ISI

certified. The R&D team always stays in tune with the changing scenario and

seldom fails in coming up with outstanding solutions every time.

N E E D L E S S T O S A Y ,behind this legendary growth lies the untiring, innovative, enthusiastic and

dedicated team work. and, of course, a flawlessly maintained value system

too. The name C.R.I. itself encapsulates the company's ethos: ‘‘ Commitment,

Reliability, Innovation’’.

Pumping trust. Worldwide.

C.R.I. submersible cables are produced in a well equipped manufacturing plant using high thermal stability, bright electrolytic

copper of 99.95% purity with low conductor resistance for high current carrying capacity with superior grade rubber & PVC

compounds. Outer sheath is made up of special grade water proof PVC / Rubber compound resistant to moisture, abrasion,

grease, oil and other environment effect. C.R.I. produces different types of submersible cables in a wide range to meet the

different needs of customers across the world. C.R.I. supplies cables in both SWG and AWG dimensions. These cables are

produced keeping vagaries of field conditions voltage fluctuations into account to ensure reliability, safety, longevity and

energy saving.

C.R.I. Submersible cables

Description

99.95% EC Grade Copper High Conductivity Better Thermal Stability Abrasion Resistant PVC Compound High Ageing * * * * *property Impervious to water, oil & Grease*

Features

To supply power to submersible motors, pumping equipments & industrial machineries.

Applications

Specifications

Available sizes in Sq.mm 1.5, 2.5, 4, 6,10, 16, 25, 35, 50, 70, 95, 120 & 150 (3 core and 4 core) - 1100 V

Available sizes in AWG 14, 12, 10, 8, 6, 4, 2, 1, 1/0, 2/0, 3/0, 4/0, & 250 MCM (3 core and 4 core) - 600 V

Armoured cables sizes 1.5, 2.5, 4, 6, 10, 16, 25 & 35 (3 core and 4 core) 1100 V

available in Sq.mmO OTemperature Range -40 C to +90 C

Conductor High conductivity annealed and bunched copper

Conductor material Plain / Tinned

Conductor Resistance PVC / Rubber Std - Class 5 of IEC60228, DIN VDE 0295, IS 8130, BS 6360

is as per : PVC / Rubber AWG - Class 5 of IEC60228, UL 83, DIN VDE 0295, IS 8130, BS 6360

Armoured Cable - IS : 1554 (Part 1) 1988

Insulation material Flexible water proof PVC / Rubber

Sheath material Flexible water proof PVC / Rubber

Sheath colour Black / Blue / Green / Any other color as be specified by the customer

PVC Std - CENELEC HD 21, IEC60227, BS 6500, DIN VDE 0281, IS 694

Rubber Std - CENELEC HD 21.152, DIN VDE 0282, PART 810, IEC 245, CEI 20-19 &

BS 6007, BS 6899

Standards conforming to PVC AWG - UL 83, IEC 60227, BS 6500, ISI 694

Rubber AWG - UL 83, IEC 60245, DIN VDE 0282, PART 810, BS 6007 & BS 6899

ARMOURED POWER CABLE - IEC 60502-1, BS 5467, BS 6724

Colour Coding : PVC / Rubber Insulated & Sheathed 3 & 4 core, flat & Round (Single / Double sheathed)

Country Core colour Codes Outer sheath colour code

USA Standard- AWG

4 core - Yellow, Black, Red, Green3 core - Yellow, Black, Red

South Africa4 core - Red, Yellow, Blue, Green with Yellow stripe3 core - Red, Yellow, Blue

4 core Round / Flat - Green3 core Round / Flat - Blue

EuropeanStandard

4 core - Brown, Blue, Black, Yellow with Green stripe3 core - Brown, Blue, Black Blue

Blue

Australia 4 core - Brown, Blue, Black, Yellow with Green stripe3 core - Brown, Blue, Yellow with Green stripe Blue

Note : Do not use single sheath cables for heavy-duty applications like sewage, slurry and de-watering pumps in which the acidic fluids and chemicals may damage the sheath. Double-sheathed cables can be used for these kind of applications, whiich can be supplied on request.

Pumping trust. Worldwide.

Page 3: C.R.I. SUBMERSIBLE CABLES · Standards conforming to PVC AWG - UL 83, IEC 60227, BS 6500, ISI 694 Rubber AWG - UL 83, IEC 60245, DIN VDE 0282, PART 810, BS 6007 & BS 6899 ARMOURED

C .R . I . SUB MERS IB LE CA B LES C .R . I . SUB MERS IB LE CA B LES 32

C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N Pumping trust. Worldwide.

PVC 3 & 4 CORE FLAT CABLES

CONDUCTOR

Nominal Area inSq.mm.

1.50

2.50

4.00

6.00

10.00

16.00

25.00

35.00

50.00

70.00

95.00

120.00

150.00

22/0.30

36/0.30

56/0.30

84/0.30

140/0.30

224/0.30

350/0.30

490/0.30

703/0.30

988/0.30

1349/0.30

608/0.50

760/0.50

0.80

0.90

1.00

1.00

1.00

1.00

1.20

1.20

1.40

1.40

1.60

1.80

2.20

3.25

3.80

4.50

5.25

6.50

8.00

10.10

11.30

13.30

15.30

18.00

19.80

22.00

1.15

1.15

1.15

1.15

1.40

1.40

2.00

2.00

2.20

2.20

2.40

2.80

4.00

6.20

6.40

7.40

8.00

9.90

11.80

14.70

16.80

18.30

20.00

23.50

25.00

30.70

12.80

14.60

16.80

18.70

23.70

28.00

35.50

39.50

45.50

51.00

60.00

65.00

76.10

12.10

7.41

4.95

3.30

1.91

1.21

0.780

0.554

0.386

0.272

0.206

0.161

0.129

14

18

26

31

42

57

72

90

115

143

165

188

216

Nominal Thickness

(in mm)

Nominal Core Dia(in mm)

Nominal Thickness

(in mm)HW

Approx. OverallDimensions (in mm)

Nos. & Diaof wire

Nos./mm.

PVC INSULATION PVC SHEATH ConductorResistance

at 20°C(max)

ohms/km

CURRENTRating at

40°CAmps.

PVC 3 CORE FLAT CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)

CONDUCTOR

1.50

2.50

4.00

6.00

10.00

16.00

25.00

35.00

50.00

70.00

95.00

120.00

22/0.30

36/0.30

56/0.30

84/0.30

140/0.30

224/0.30

350/0.30

490/0.30

703/0.30

988/0.30

1349/0.30

608/0.50

0.80

0.90

1.00

1.00

1.00

1.00

1.20

1.20

1.40

1.40

1.60

1.80

3.25

3.80

4.50

5.25

6.50

8.00

10.10

11.30

13.30

15.30

18.00

19.80

1.30

1.30

1.45

1.50

1.80

1.95

2.00

2.00

2.20

2.20

2.40

3.50

6.20

6.40

7.40

8.00

9.90

11.80

14.70

16.80

18.30

20.00

23.50

27.40

15.80

18.00

21.00

24.50

29.70

36.00

45.10

50.10

58.10

66.50

77.30

87.00

12.10

7.41

4.95

3.30

1.91

1.21

0.780

0.554

0.386

0.272

0.206

0.161

14

18

26

31

42

57

72

90

115

143

165

188

PVC INSULATION PVC SHEATHConductorResistance

at 20°C(max)

ohms/km

CURRENTRating at

40°CAmps.

PVC 4 CORE FLAT CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)

Nominal Area inSq.mm.

Nominal Thickness

(in mm)

Nominal Core Dia(in mm)

Nominal Thickness

(in mm)HW

Approx. OverallDimensions (in mm)

Nos. & Diaof wire

Nos./mm.

CONDUCTOR

1.50

2.50

4.00

6.00

10.00

16.00

25.00

35.00

50.00

70.00

95.00

120.00

150.00

22/0.30

36/0.30

56/0.30

84/0.30

140/0.30

224/0.30

350/0.30

490/0.30

703/0.30

988/0.30

1349/0.30

608/0.50

760/0.50

0.80

0.90

1.00

1.00

1.00

1.00

1.20

1.20

1.40

1.40

1.60

1.90

2.00

3.25

3.80

4.50

5.25

6.50

8.00

10.10

11.30

13.30

15.30

18.00

19.80

22.00

1.50

1.50

1.60

1.60

2.00

2.00

2.40

2.60

3.10

3.20

3.50

3.80

4.00

10.00

11.00

13.00

14.60

18.00

21.20

26.50

29.50

34.80

39.30

45.70

50.20

55.30

12.10

7.41

4.95

3.30

1.91

1.21

0.780

0.554

0.386

0.272

0.206

0.161

0.129

14

18

26

31

42

57

72

90

115

143

165

188

216

Approx. OverallDimensions

(in mm)

PVC INSULATION PVC SHEATH ConductorResistance

at 20°C(max)

ohms/km

CURRENTRating at

40°CAmps.

PVC 3 CORE ROUND CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)

Nominal Thickness

(in mm)

Nominal Core Dia(in mm)

Nominal Thickness

(in mm)

Nominal Area inSq.mm.

Nos. & Diaof wire

Nos./mm.

PVC 3 & 4 CORE ROUND CABLES

CONDUCTOR

1.50

2.50

4.00

6.00

10.00

16.00

25.00

35.00

50.00

70.00

95.00

120.00

150.00

22/0.30

36/0.30

56/0.30

84/0.30

140/0.30

224/0.30

350/0.30

490/0.30

703/0.30

988/0.30

1349/0.30

608/0.50

760/0.50

0.80

0.90

1.00

1.00

1.00

1.00

1.20

1.20

1.40

1.40

1.60

1.90

2.00

3.25

3.80

4.50

5.25

6.50

8.00

10.10

11.30

13.30

15.30

18.00

19.80

22.00

1.50

1.65

1.65

1.65

2.00

2.00

2.40

2.60

3.10

3.20

3.50

3.80

4.00

10.80

12.50

14.10

16.00

20.35

23.40

29.20

32.40

38.25

43.30

50.40

55.30

61.00

12.10

7.41

4.95

3.30

1.91

1.21

0.780

0.554

0.386

0.272

0.206

0.161

0.129

14

18

26

31

42

57

72

90

115

143

165

188

216

PVC INSULATION PVC SHEATH ConductorResistance

at 20°C(max)

ohms/km

CURRENTRating at

40°CAmps.

PVC 4 CORE ROUND CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)

Approx. OverallDimensions

(in mm)

Nominal Thickness

(in mm)

Nominal Core Dia(in mm)

Nominal Thickness

(in mm)

Nominal Area inSq.mm.

Nos. & Diaof wire

Nos./mm.

Page 4: C.R.I. SUBMERSIBLE CABLES · Standards conforming to PVC AWG - UL 83, IEC 60227, BS 6500, ISI 694 Rubber AWG - UL 83, IEC 60245, DIN VDE 0282, PART 810, BS 6007 & BS 6899 ARMOURED

C .R . I . SUB MERS IB LE CA B LES C .R . I . SUB MERS IB LE CA B LES 54

C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N Pumping trust. Worldwide.

RUBBER 3 & 4 CORE FLAT CABLES

CONDUCTOR

1.50

2.50

4.00

6.00

10.00

16.00

25.00

35.00

50.00

70.00

95.00

120.00

150.00

22/0.30

36/0.30

56/0.30

84/0.30

140/0.30

224/0.30

350/0.30

490/0.30

703/0.30

988/0.30

1349/0.30

608/0.50

760/0.50

0.80

0.90

1.00

1.00

1.00

1.00

1.20

1.20

1.40

1.40

1.60

1.80

2.20

3.25

3.80

4.50

5.25

6.50

8.00

10.10

11.30

13.30

15.30

18.00

19.80

22.00

1.15

1.15

1.15

1.15

1.40

1.40

2.00

2.00

2.20

2.20

2.40

2.80

4.00

6.20

6.40

7.40

8.00

9.90

11.80

14.70

16.80

18.30

20.00

23.50

25.00

30.70

12.80

14.60

16.80

18.70

23.70

28.00

35.50

39.50

45.50

51.00

60.00

65.00

76.10

12.10

7.41

4.95

3.30

1.91

1.21

0.780

0.554

0.386

0.272

0.206

0.161

0.129

RUBBER INSULATION

RUBBER SHEATH ConductorResistance

at 20°C(max)

ohms/km

CURRENTRating at

40°CAmps.

RUBBER 3 CORE FLAT CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)

14

18

26

31

42

57

72

90

115

143

165

188

216

Nominal Area inSq.mm.

Nominal Thickness

(in mm)

Nominal Core Dia(in mm)

Nominal Thickness

(in mm)HW

Approx. OverallDimensions

(in mm)

Nos. & Diaof wire

Nos./mm.

CONDUCTOR

1.50

2.50

4.00

6.00

10.00

16.00

25.00

35.00

50.00

70.00

95.00

120.00

22/0.30

36/0.30

56/0.30

84/0.30

140/0.30

224/0.30

350/0.30

490/0.30

703/0.30

988/0.30

1349/0.30

608/0.50

0.80

0.90

1.00

1.00

1.00

1.00

1.20

1.20

1.40

1.40

1.60

1.80

3.25

3.80

4.50

5.25

6.50

8.00

10.10

11.30

13.30

15.30

18.00

19.80

1.30

1.30

1.45

1.50

1.80

1.95

2.00

2.00

2.20

2.20

2.40

3.50

6.20

6.40

7.40

8.00

9.90

11.80

14.70

16.80

18.30

20.00

23.50

27.40

15.80

18.00

21.00

24.50

29.70

36.00

45.10

50.10

58.10

66.50

77.30

87.00

12.10

7.41

4.95

3.30

1.91

1.21

0.780

0.554

0.386

0.272

0.206

0.161

RUBBER INSULATION RUBBER SHEATHConductorResistance

at 20°C(max)

ohms/km

CURRENTRating at

40°CAmps.

RUBBER 4 CORE FLAT CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)

14

18

26

31

42

57

72

90

115

143

165

188

Nominal Area inSq.mm.

Nominal Thickness

(in mm)

Nominal Core Dia(in mm)

Nominal Thickness

(in mm)HW

Approx. OverallDimensions

(in mm)

Nos. & Diaof wire

Nos./mm.

CONDUCTOR

1.50

2.50

4.00

6.00

10.00

16.00

25.00

35.00

50.00

70.00

95.00

120.00

150.00

22/0.30

36/0.30

56/0.30

84/0.30

140/0.30

224/0.30

350/0.30

490/0.30

703/0.30

988/0.30

1349/0.30

608/0.50

760/0.50

0.80

0.90

1.00

1.00

1.00

1.00

1.20

1.20

1.40

1.40

1.60

1.90

2.00

3.25

3.80

4.50

5.25

6.50

8.00

10.10

11.30

13.30

15.30

18.00

19.80

22.00

1.50

1.50

1.60

1.60

2.00

2.00

2.40

2.60

3.10

3.20

3.50

3.80

4.00

10.00

11.00

13.00

14.60

18.00

21.20

26.50

29.50

34.80

39.30

45.70

50.20

55.30

12.10

7.41

4.95

3.30

1.91

1.21

0.780

0.554

0.386

0.272

0.206

0.161

0.129

RUBBER INSULATION RUBBER SHEATH ConductorResistance

at 20°C(max)

ohms/km

CURRENTRating at

40°CAmps.

RUBBER 3 & 4 CORE ROUND CABLES

RUBBER 3 CORE ROUND CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)

Rubber

Rubber

Rubber

Rubber

Rubber

Rubber

14

18

26

31

42

57

72

90

115

143

165

188

216

Nominal Area inSq.mm.

Nominal Thickness

(in mm)

Nominal Core Dia(in mm)

Nominal Thickness

(in mm)

Approx. OverallDimensions

(in mm)

Nos. & Diaof wire

Nos./mm.

CONDUCTOR

1.50

2.50

4.00

6.00

10.00

16.00

25.00

35.00

50.00

70.00

95.00

120.00

150.00

22/0.30

36/0.30

56/0.30

84/0.30

140/0.30

224/0.30

350/0.30

490/0.30

703/0.30

988/0.30

1349/0.30

608/0.50

760/0.50

0.80

0.90

1.00

1.00

1.00

1.00

1.20

1.20

1.40

1.40

1.60

1.90

2.00

3.25

3.80

4.50

5.25

6.50

8.00

10.10

11.30

13.30

15.30

18.00

19.80

22.00

1.50

1.65

1.65

1.65

2.00

2.00

2.40

2.60

3.10

3.20

3.50

3.80

4.00

10.80

12.50

14.10

16.00

20.35

23.40

29.20

32.40

38.25

43.30

50.40

55.30

61.00

12.10

7.41

4.95

3.30

1.91

1.21

0.780

0.554

0.386

0.272

0.206

0.161

0.129

RUBBER INSULATION RUBBER SHEATH ConductorResistance

at 20°C(max)

ohms/km

CURRENTRating at

40°CAmps.

RUBBER 4 CORE ROUND CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)

14

18

26

31

42

57

72

90

115

143

165

188

216

Nominal Area inSq.mm.

Nominal Thickness

(in mm)

Nominal Core Dia(in mm)

Nominal Thickness

(in mm)

Approx. OverallDimensions

(in mm)

Nos. & Diaof wire

Nos./mm.

Page 5: C.R.I. SUBMERSIBLE CABLES · Standards conforming to PVC AWG - UL 83, IEC 60227, BS 6500, ISI 694 Rubber AWG - UL 83, IEC 60245, DIN VDE 0282, PART 810, BS 6007 & BS 6899 ARMOURED

C .R . I . SUB MERS IB LE CA B LES C .R . I . SUB MERS IB LE CA B LES 76

C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N Pumping trust. Worldwide.

3 CORE

EPDM RUBBER INSULATED & EPDM / NBR RUBBER SHEATHED ROUND CABLES 3 & 4 CORE - DOUBLE SHEATHED

Conductor Area

(in Sq.mm)Nominal)

No. of strands and

Diameter(Nominal)

Thickness ofInsulation (in mm)

(Nominal)

Thickness ofSheath(in mm)

(Nominal)

Maximum Overall

Dimensions(in mm)

Maximum Conductor Resistance

Oat 20 C Ohms/km

Current Carrying Capacity

Oat 40 C in Amps

1.50

2.50

4.00

6.00

10.00

16.00

25.00

35.00

50.00

70.00

95.00

22/0.30

36/0.30

56/0.30

84/0.30

140/0.30

226/0.30

354/0.30

495/0.30

703/0.30

440/0.45

475/0.50

0.80

0.90

1.00

1.00

1.00

1.00

1.20

1.20

1.40

1.40

1.60

1.50

1.50

1.60

1.60

2.00

2.00

2.15

2.15

2.25

2.45

2.40

10.00

11.00

13.00

14.60

18.00

21.20

26.00

28.30

33.50

37.80

43.50

12.10

7.41

4.95

3.30

1.91

1.21

0.780

0.554

0.386

0.272

0.206

14

18

26

31

42

57

72

90

115

143

165

4 CORE

Conductor Area

(in Sq.mm)Nominal)

No. of strands and

Diameter(Nominal)

Thickness ofInsulation (in mm)

(Nominal)

Thickness ofSheath(in mm)

(Nominal)

Maximum Overall

Dimensions(in mm)

Maximum Conductor Resistance

Oat 20 C Ohms/km

Current Carrying Capacity

Oat 40 C in Amps

1.50

2.50

4.00

6.00

10.00

16.00

25.00

35.00

50.00

70.00

95.00

22/0.30

36/0.30

56/0.30

84/0.30

140/0.30

226/0.30

354/0.30

495/0.30

703/0.30

440/0.45

475/0.50

0.80

0.90

1.00

1.00

1.00

1.00

1.20

1.20

1.40

1.40

1.60

1.50

1.65

1.65

1.65

2.00

2.00

2.20

2.20

2.30

2.60

2.65

10.80

12.50

14.10

16.00

20.35

23.40

28.80

31.50

37.30

42.20

48.80

12.10

7.41

4.95

3.30

1.91

1.21

0.780

0.554

0.386

0.272

0.206

14

18

26

31

42

57

72

90

115

143

165

NBR - Nitrile butadiene rubber.Cables with EPDM Insulation & NBR Sheath is equivalent to H07RN-F Standards.Cables on request with lead free NBR Sheath also can be supply on additional cost.

Note : The number of strands are approximate and strands diameter is nominal ; Conductor resistance is as per class 5 of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360 In view of continuous developments, the information / descriptions / specifications / illustrations are subject to change without notice.

ConductorSize

(AWG)

No. ofConductor

Nos. & Dia.of wire

Core Dia.(mm)

Nominal Sheth

Thickness (mm)

MaximumOverall

Dimenssions (in mm)

Current CarryingCapacity

at 40°C in Amps

W H

3

3

3

3

3

3

3

3

3

3

3

3

3

41 x 0.254

65 x 0.254

105 x 0.254

168 x 0.254

226 x 0.254

420 x 0.254

665 x 0.254

817 x 0.254

1045 x 0.254

1330 x 0.254

1672 x 0.254

2116 x 0.254

646 x 0.5

3.60

4.30

5.10

6.30

7.60

9.90

11.10

13.60

13.60

15.60

18.00

19.80

20.60

1.15

1.15

1.15

1.40

1.40

2.00

2.00

2.20

2.20

2.20

2.40

2.65

2.80

13.30

15.60

17.70

22.30

26.30

32.30

35.90

45.50

45.50

51.00

61.00

65.00

68.00

6.20

7.00

7.40

9.30

10.60

13.10

14.30

18.30

18.30

20.00

23.50

25.50

28.00

15

20

30

50

65

85

115

130

150

175

175

230

255

14

12

10

8

6

4

2

1

1/0

2/0

3/0

4/0

250 MCM

HEAVY DUTY PVC JACKETED FLAT SUBMERSIBLE PUMP CABLES ( WITHOUT GROUND)

PVC Jacket

PVC Jacket

PVC insulation of cores

PVC AWG SUBMERSIBLE PUMP CABLES

PVC

without ground flat cable with ground flat cable

ConductorSize

(AWG)

No. ofConductor

Nos. & Dia.of wire

Ground ConductorSize (AWG)

Core Dia.(mm)

Nominal Sheath

Thickness(mm)

Maximum Overall

Dimensions (in mm)

Current CarryingCapacityat 40°C in AmpsW H

3

3

3

3

3

3

3

3

3

3

3

3

41 x 0.254

65 x 0.254

105 x 0.254

168 x 0.254

226 x 0.254

420 x 0.254

665 x 0.254

817 x 0.254

1045 x 0.254

1330 x 0.254

1672 x 0.254

2116 x 0.254

3.85

4.50

5.30

6.50

8.00

10.10

11.30

13.60

15.60

18.00

18.00

19.80

1.15

1.15

1.15

1.40

1.40

2.00

2.00

2.20

2.20

2.20

2.65

3.85

15

20

30

50

65

85

115

130

150

175

175

230

18.00

21.00

24.30

29.70

36.00

45.10

50.10

58.10

58.10

66.50

77.30

87.00

6.50

7.60

7.90

9.90

11.80

14.70

16.20

19.00

19.00

21.50

23.50

27.80

14

12

10

8

6

4

2

1

1/0

2/0

3/0

4/0

14

12

10

10

8

8

6

6

6

6

2

2

HEAVY DUTY PVC JACKETED FLAT SUBMERSIBLE PUMP CABLES ( WITH GROUND)

Page 6: C.R.I. SUBMERSIBLE CABLES · Standards conforming to PVC AWG - UL 83, IEC 60227, BS 6500, ISI 694 Rubber AWG - UL 83, IEC 60245, DIN VDE 0282, PART 810, BS 6007 & BS 6899 ARMOURED

C .R . I . SUB MERS IB LE CA B LES C .R . I . SUB MERS IB LE CA B LES 98

C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N Pumping trust. Worldwide.

ConductorSize

(AWG)

No. ofConductor

Nos. & Dia.of wire

CoreDia.

(mm)

Nominal Sheath

Thickness(mm)

3

3

3

3

3

3

3

3

3

3

3

3

3

41 x 0.254

65 x 0.254

105 x 0.254

168 x 0.254

226 x 0.254

420 x 0.254

665 x 0.254

817 x 0.254

1045 x 0.254

1330 x 0.254

1672 x 0.254

2116 x 0.254

2503 x 0.254

3.85

4.50

5.30

6.50

8.00

10.10

11.30

13.60

13.60

15.60

18.00

19.80

20.60

1.15

1.15

1.15

1.40

1.40

2.00

2.00

2.20

2.20

2.20

2.40

2.65

2.80

14.60

16.80

18.70

23.70

28.00

35.50

39.50

45.50

45.50

51.00

60.00

65.00

68.00

6.40

7.40

7.90

9.90

11.40

14.70

16.20

18.30

18.30

20.00

23.50

25.00

28.00

14

12

10

8

6

4

2

1

1/0

2/0

3/0

4/0

250 MCM

Heavy Duty Rubber Jacketed Flat Submersible Pump Cables ( Without Ground)

Rubber Jacket

without ground flat cable with ground flat cable

Rubber Jacket

Rubber insulation of cores

RUBBER AWG SUBMERSIBLE PUMP CABLES

Maximum OverallDimenssions

(in mm)

W H

Current CarryingCapacityat 40°C in Amps

15

20

30

50

65

85

115

130

150

175

175

230

255

ConductorSize

(AWG)

No. ofConductor

Nos. & Dia.of wire

Ground ConductorSize (AWG)

Core Dia.(mm)

Nominal Sheath

Thickness(mm)

3

3

3

3

3

3

3

3

3

3

3

3

41 x 0.254

65 x 0.254

105 x 0.254

168 x 0.254

266 x 0.254

420 x 0.254

665 x 0.254

817 x 0.254

1045 x 0.254

1330 x 0.254

1672 x 0.254

2116 x 0.254

3.85

4.50

5.30

6.50

8.00

10.10

11.30

13.60

15.60

18.00

19.80

19.80

1.15

1.15

1.15

1.40

2.00

2.00

2.20

2.20

2.20

2.20

3.85

3.85

18.00

21.00

24.30

29.70

36.00

45.10

50.10

58.10

58.10

66.50

77.30

87.00

6.50

7.60

7.90

9.90

11.80

14.70

16.20

19.00

19.00

21.50

23.50

27.80

14

12

10

8

6

4

2

1

1/0

2/0

3/0

4/0

14

12

10

10

8

8

6

6

6

4

2

2

Heavy Duty Rubber Jacketed Flat Submersible Pump Cables ( With Ground)

Maximum Overall

Dimenssions (in mm)

W H

Current CarryingCapacityat 40°C in Amps

15

20

30

50

65

85

115

130

150

175

175

230

ARMOURED POWER CABLES

3 Core Copper conductor XLPE Insulated PVC sheathed Armoured Cable

Size (No. of

Core x Nom.Area of

Conductor)

ConductorConfiguration

No./Dia ofWire

Max. ConductorResistance

oat 20 C Ohm/Km.

NominalInsulationThickness

in mm

Armour Size in mm

Nominal Sheath

Thickness in mm

OverallDiameter

in mm

Current Carrying Capacity in Amps

Ground Air

3C x 1.5

3C x 2.5

3C x 4

3C x 6

3C x 10

3C x 16

3C x 25

3C x 35

3C x 50

3C x 70

3C x 95

3C x 120

3C x 150

3C x 185

3C x 240

3C x 300

3C x 400

1/1.38

1/1.79

1/2.24

1/2.78

7/1.35

7/1.72

7/2.18

7/2.52

7/3.02

19/2.18

19/2.52

19/2.85

19/3.21

37/2.52

37/2.85

37/3.21

61/2.88

12.1

7.41

4.61

3.08

1.83

1.15

0.727

0.524

0.387

0.268

0.193

0.153

0.124

0.0991

0.0754

0.0601

0.047

0.7

0.7

0.7

0.7

0.7

0.7

0.9

0.9

1

1.1

1.1

1.2

1.4

1.6

1.7

1.8

2

-

-

-

-

-

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

1.8

1.8

1.8

1.8

1.8

1.8

2

2

2

2.2

2.2

2.2

2.4

2.6

2.8

3

3.4

14

15

16

17

19.5

21.5

22.5

24

27.5

31

35.5

38.5

42

46.5

52

61.5

64

26

27

45

56

74

95

122

146

173

212

254

287

321

362

418

469

528

23

24

41

52

70

89

119

147

179

226

279

320

365

422

500

574

662

1100 Volts grade, Copper Flexible Conductor, XLPE Insulated, Cores Laid up, PVC extruded inner-sheath, Galvanized Steel Wire /

Strip Armoured. Extruded PVC Sheathed power cables.

Strips(Width x

Thickness)mm

Round Diameterof wire in

mm

1.4

1.4

1.4

1.4

1.4

-

-

-

-

-

-

-

-

-

-

-

-

+Overall diameter of cable has a tolerance (±) 3mm for the above 30mm / othrewise (±) 2mm below 30mm

4 Core Copper conductor XLPE Insulated PVC sheathed Armoured Cable

Size (No. of

Core x Nom.Area of

Conductor)

ConductorConfiguration

No./Dia ofWire

Max. ConductorResistance

oat 20 C Ohm/Km.

NominalInsulationThickness

in mm

Armour Size in mm

Nominal Sheath

Thickness in mm

OverallDiameter

in mm

Current Carrying Capacity in Amps

Ground Air

4C x 1.5

4C x 2.5

4C x 4

4C x 6

4C x 10

4C x 16

4C x 25

4C x 35

4C x 50

4C x 70

4C x 95

4C x 120

4C x 150

4C x 185

4C x 240

4C x 300

4C x 400

1/1.38

1/1.79

1/2.24

1/2.78

7/1.35

7/1.72

7/2.18

7/2.52

7/3.02

19/2.18

19/2.52

19/2.85

19/3.21

37/2.52

37/2.85

37/3.21

61/2.88

12.1

7.41

4.61

3.08

1.83

1.15

0.727

0.524

0.387

0.268

0.193

0.153

0.124

0.0991

0.0754

0.0601

0.047

0.7

0.7

0.7

0.7

0.7

0.7

0.9

0.9

1

1.1

1.1

1.2

1.4

1.6

1.7

1.8

2

-

-

-

-

-

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

4 x 0.80

1.8

1.8

1.8

1.8

2

2

2

2

2.2

2.2

2.4

2.4

2.6

2.8

3.0

3.2

3.4

15

16

17

18

21

23

27

30

34

38.5

43

47.5

52.5

58

64.5

70.5

79

26

34

45

56

74

95

122

146

173

212

254

287

321

362

418

469

528

23

30

41

52

70

89

119

147

179

226

279

320

365

422

500

574

662

Strips(Width x

Thickness)mm

Round Diameterof wire in

mm

1.4

1.4

1.4

1.4

1.4

-

-

-

-

-

-

-

-

-

-

-

-

+Overall diameter of cable has a tolerance (±) 3mm for the above 30mm / othrewise (±) 2mm below 30mm

Page 7: C.R.I. SUBMERSIBLE CABLES · Standards conforming to PVC AWG - UL 83, IEC 60227, BS 6500, ISI 694 Rubber AWG - UL 83, IEC 60245, DIN VDE 0282, PART 810, BS 6007 & BS 6899 ARMOURED

C .R . I . SUB MERS IB LE CA B LES C .R . I . SUB MERS IB LE CA B LES 1110

C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N Pumping trust. Worldwide.

C.R.I. Z FIRE FR BUILDING WIRES

C.R.I. Z FIRE FR Building Wires are manufactured at its state of the art manufacturing facility located in Coimbatore, India. The

systems at the manufacturing facility are certified for ISO-9001 and the product manufactured to meet the relevant PVC cables

standards IS 694.

Conductor

These wires are manufactured using Electrolytic Grade 99.97% purity copper with more than 100% conductivity. The

conductors are drawn using state-of-the-art multiwire drawing machine as fine wires and bunched with concentricity according

to IS 8130. High purity and conductivity of copper ensures greater saving of electrical energy which helps to reduce electricity

bills.

Insulation

The bunched conductors are insulated with specially formulated and in-house manufactured FR-(Flame Retardant) PVC

compound with high oxygen index and temperature index. These properties help in restricting the spread of fire even at very

high temperatures. Wires are insulated with double layer, Natural FR PVC compound as first layer and Natural + Skin color

as second layer which gives double protection in insulation.

All wires are tested with online high voltage spark tester to ensure that there are no weak spots in the insulation, pin holes,

black spots and any other defects during extrusion. These wires meet the requirements of IS 694 with latest amendments with

improved fire performance for category C1. This ensures extra protection against electrical shocks, short circuits and fire.

Nominal Area of

Conductor

No. of strands/

Nominal Dia of wire**

Thickness ofinsulation

(Nom.)

Approx. Overall

Diameter

Current Carrying Capacity#2 Cables, Single Phase

In Conduit/Trunking

Unenclosed-Clipped directly to

a surface or oncable tray

Max. Resistance

per km O@ 20 C as

per IS 8130

sq. mm.

1.0

1.5

2.5

4.0

6.0

mm

14/0.30

22/0.30

36/0.30

56/0.30

84/0.30

mm

0.70

0.70

0.80

0.80

0.80

mm

2.70

3.00

3.60

4.00

4.60

Amps.

11

13

18

24

31

Amps.

12

16

22

29

37

ohms

18.10

12.10

7.41

4.95

3.30

Single Core, unsheathed cables in voltage grade 1100v IS 694 ISI CM/L-3406447

Standard Colours: Red, Yellow, Blue, Black, Green, Grey & White. Can also be supplied in any colour based on the request.

Standard Length: 90 Meter Coils in Protective Carton. Project Coils of 180 / 270 mtrs also available.# As per IS 3961(Part V) : 1968.** Nominal Dia to meet the Specified resistance.

FR PROPERTIES

TEST

Critical OxygenIndex

TemperatureIndex

Meets requirement of Flammability Test as per IS 694

TEST METHOD

IS 10810 : 1984;Part 58

IS 10810 : 1984;Part 64

Oxygen IndexMinimum 29%

MinimumTemperatureIndex 250°C

SPECIFIED VALUES

Page 8: C.R.I. SUBMERSIBLE CABLES · Standards conforming to PVC AWG - UL 83, IEC 60227, BS 6500, ISI 694 Rubber AWG - UL 83, IEC 60245, DIN VDE 0282, PART 810, BS 6007 & BS 6899 ARMOURED

C .R . I . SUB MERS IB LE CA B LES C .R . I . SUB MERS IB LE CA B LES12

C O M M I T M E N T R E L I A B I L I T Y I N N O V A T I O N Pumping trust. Worldwide.

CONVERSION TABLE - Sq.mm, Sq.Inch , CIRCULAR MILS & AWG

Sq.mm Sq.Inch Cir.Mils AWG

1000975950

925900875

850825800

775750725

700675650

625600575

550525500

475450425

400375350

325300275

250225200

175150125

-10095

90-

85

1.5501.5111.472

1.4341.3951.356

1.3171.2791.240

1.2011.1631.124

1.0851.0461.008

0.9690.9300.891

0.8530.8140.775

0.7360.6980.659

0.6200.5810.542

0.5040.4650.526

0.3880.3490.310

0.2710.233

0.1938

-0.15500.1472

0.1395-

0.1317

197400019247001875300

82600017766001727300

167790016286001579200

152990014805001431200

138180013325001283100

123380011844001135100

10857001036400987000

937700888300839000

789600740300690900

641600592200542900

493500444200394800

345500296100246800

211600197400187530

177660167800167790

---

---

---

---

---

---

---

---

---

---

---

---

4/0--

-3/0-

Sq.mm Sq.Inch Cir.Mils AWG

807570

-6560

55-

50

45-

40

35-

30

-25-

2019.519.0

18.518.017.5

17.0-

16.5

16.015.515.0

14.514.013.5

-13.012.5

12.011.511.0

-10.510.0

0.12400.11630.1085

-0.10080.0930

0.0853-

0.0775

0.0698-

0.0620

0.0542-

0.0465

-0.0388

-

0.03100.03020.0294

0.02870.02790.0271

0.0264-

0.0256

0.02480.02400.0233

0.02250.02170.0209

-0.02010.0194

0.01860.01780.0171

-0.01630.0155

157920148050138180

133100128310118440

10857010560098700

888308369078960

690906636059220

526204935041740

394803849037510

365203552034550

335603309032560

315803060029610

286202764026650

262402566024680

236902270021710

208202073019740

-

2/0

1/0

1

2

3

4

-

-

5

-

-

6

-

7

Sq.mm Sq.Inch Cir.Mils AWG

9.59.08.5

-8.07.5

7.0-

6.5

6.05.5-

5.04.754.50

4.25-

4.0

3.753.50

-

3.253.0

2.75

-2.502.25

-2.0

1.75

-1.50

-

1.25-

1.0

0.9-

0.8

0.750.7-

0.6-

0.5

0.014720.013950.01317

-0.012400.01163

0.01085-

0.01008

0.009300.00853

-

0.007750.007360.00698

0.00659-

0.00620

0.005810.00542

-

0.005040.004650.00426

-0.003880.00349

-0.003100.00271

-0.00233

-

0.00194-

0.00155

0.00140-

0.00124

0.001160.00109

-

0.00093-

0.000775

187531776616779

165101579214805

138181309012831

118441085710380

987093778883

839082307896

740369096530

641659225429

518049354442

411039483455

326029612580

246820501974

177716201579

148113821290

11841029987

-

8

9

10

-

11

12

-

13

14

15

16

17

18

19

20To Convert :

Meters to feet

Kilometers to feet

Feet to meters

Feet to kilometers

Kilograms to pounds

Pounds to kilograms

Pounds 1000 ft. to pounds 1000 meters

Pounds 1000 ft to kilograms 1000 meters

Kilograms 1000 meters to pounds 1000 feetO OC = 5/9 ( F - 32)

Multiply by :

3.2808

3280.8

0.3048

0.0003048

2.205

0.4536

3.2808

1.4882

0.6719O OF = 32 + 5/9 ( C)

When you have a good thing going it is quite

in the fitting of things that recognitions come

our way. Several prestigious awards, which

decorate our shelf, say it all. These rewards

not only acknowledge our position as a leader

in the water pump industry but also serve as

reminders about what the customer expects

from a winner. And we, as ever, have our ears

perfectly tuned to customer expectations.

W I N N I N G W A Y S