Page 1: DATA SHEET VT 4.8 ROTARY VANE VACUUM PUMPS

MAKE IT BECKER.

DATA SHEET

VT 4.8ROTARY VANEVACUUM PUMPSoil-free

air-cooled

Page 2: DATA SHEET VT 4.8 ROTARY VANE VACUUM PUMPS

2 • BECKER VT 4.8

a

b

de

3.2 f

0.3

m

p

o

h

g

n

i

3.1

r

G3/8

k

cV3

P3V1

P4V4

V3

P3

V1

1~ *

V2

V1 (V2)V3 (V4)P3 (P4)

(XX)*

▪ ▪▪

Vacuum connection (G⅜)

Vacuum regulating valve

Blow-off valve

Alternative

The size and position of the capacitor can

change with changed voltage / frequency.

Including integrated suction air filter

The motor illustration may vary

Dimensions in inch

3~ 01 7.1 9.9 – 5.6 4.0 3.3 5.5 2.8 4.0 – 6.4 4.4 5.4 0.27 8.6

3~ 02+03 6.8 9.1 – 4.9 3.9 2.7 5.2 2.5 3.7 – 6.1 3.9 4.6 0.24 7.8

1~ 01 6.8 9.9 ≈3.7 4.9 4.6 3.5 5.2 2.5 3.7 5.6 6.1 3.9 4.6 0.24 7.8

Motors inch

# a b c d e f g h i k m n o p r

1)

2)

According to DIN EN ISO 3744 (KpA = 3 dB(A)), 39.4 inch distance, at medium load, both connection sides pipedDepending on the motor

Suction air rate Vacuum Emission sound pressure level 1)

Weightwith motor 2)

CFM Torr in. HgV dB(A) lbs

50 Hz 60 Hz 50 & 60 Hz 50 & 60 Hz 50 Hz 60 Hz

4.7 5.4 112.5 25.1 58 61 ≈20.9

Page 3: DATA SHEET VT 4.8 ROTARY VANE VACUUM PUMPS

BECKER VT 4.8 • 3

▪ Current consumption and rotation speed may vary. Tolerance in each case -1.5/+2%

1~ Motor

# 50 Hz 60 Hz Version

hp V rpm A hp V rpm A

01 0.5 230 ±10% 2700 3.9 0.6 230 ±10% 3200 3.4IP54 • ISO F • bimetal

10 μF (450 V)

3~ Motor

# 50 Hz 60 Hz Version

hp V rpm A hp V rpm A

01 0.5 Δ230/Y400 IE2 2920 2.30/1.33

0.6 Δ265/Y460 IE3 3515 2.13/1.23

IP55 • ISO F • bimetal0.5 Δ230/Y400 IE3 3480 1.90/1.10

0.6 Δ208/Y360 IE4 3455 1.90/1.10

02 0.5175–260/300–450

2800 2.35/1.35 0.6202–300/350–520

3150 2.40/1.40 IP54 • ISO F

03 0.5175–260/300–450

2800 2.35/1.36 0.6202–300/350–520

3150 2.40/1.40UL • CSA

IP54 • ISO F

Page 4: DATA SHEET VT 4.8 ROTARY VANE VACUUM PUMPS

4 • BECKER VT 4.8

Reference data (atmosphere): 0 in. HgV, 68°F; Tolerance: ±10%

VACUUM [Torr]750 700 600 500 400 300 200 100 0

6

60 Hz

50 Hz

refers to theatmospheric pressure

refers to theintake pressure

SU

CT

ION

AIR

RA

TE

[C

FM]

5

4

3

2

1

0

EX

HA

US

T A

IR T

EM

PE

RA

TU

RE

[°F

] 200

60 Hz

50 Hz

150

100

50

0

0.5

60 Hz

50 Hz

MO

TO

R S

HA

FT P

OW

ER

[h

p]

0.4

0.3

0.2

0.1

0.0

0 10 20 29.5

VACUUM [in. HgV]

Page 5: DATA SHEET VT 4.8 ROTARY VANE VACUUM PUMPS

BECKER VT 4.8 • 5

VARIANTS AND ACCESSORIES

VT 4.8/0-28

▪ with handle

VT 4.8 DC 1)

▪ with 24V DC motor

5.9≈

1.8

2.6

1)

▪See separate data sheetDimensions in inch – For other dimensions, see the figure on page 2.

3.9

0.8

3.2

3.2

2.6

3.3 1

2

4.4

PEDESTAL ADAPTER T4.8-0-24.1

▪▪

for VT 4.8 with IE motor for replicating the

pedestal bore pattern of the wide range motor

order number: 57040027200

scope of delivery:

- 2 pedestal adapters

- 4 rubber buffers with threaded pins M6

- 4 nuts M6

- 4 hexagon socket screws M6x25

- 8 washers

1

2

pedestal dimension of

IE motor

corresponds to pedestal

size of wide-range motor

Page 6: DATA SHEET VT 4.8 ROTARY VANE VACUUM PUMPS

MAKE IT BECKER.

www.becker-international.com

20

21-

07-

21

Rig

ht

of

mo

difi

cat

ion

re

serv

ed