Intruder
Access Control
CCTV
Perimeter
Building Management
Asset Tracking
Intercom
Concierge
Fire
Staff Safety
BuildingFire & Security
Management Systems
Datalog 4 SMS
iinntteelllliiggeennccee in software
Intelligence in softwareThe Datalog 4 security managementconcept is the latest software suite toevolve from over 10 years of installationand application experience.
One Routine for All Systems
Our concept reduces the complexity foroperators responding to the wide range ofdifferent manufactures control panels,often found in a control room or securitygatehouse.
The system offers a single operatingroutine for ‘ACCEPT’ & ‘RESET’ for allsystems under control.
Operators use a single screen to controlmultiple alarm input and output interaction,combined with audio and video verification.
User Systems Management
Datalog provides the user with a very easy to usegraphics package to manage and monitor on siteand offsite Building Fire & Security systems.
Colour graphics provide clear and concise locationreporting, eliminating the need for extensiveoperator training.
The management system can be configured toautomatically respond to events, even when theoperator is away from the system.
Intelligence in software can be used to reduce theneed for operator intervention as the system canbe programmed to:-
• Display the event and location
• Call up cameras to monitors
• Start Pre & Post digital recording playback
• Page or Text remote signalling
• Switch Outputs & Sounders
AlarmManagement
PerimeterDetection
Fire Systems
AccessControl
RadioPaging
Intercom
AssetProtection
BuildingMonitoring
CCTV
DigitalRecording
AudioVerification
Staff SafetySystems
Single or Dual Screen Operation
Datalog 4 is Windows 98/NT/2000/XPcompatible and is easily configurable for eitherstand alone or multiple workstations on anetwork.
Datalog graphics offer a range of operatorcontrol capabilities including; mouse, keyboard,touch-screen, graphic tablet, remote control orby volt free contact change of state.
The system includes on-screen dynamic icons,making simple work of complex tasks.
Dual screen displays are available to combinegraphics with text and panel emulation for largersystems.
Alarm Display Management
Navigation around the system is simplified by pointing or clickingon the graphical display to zoom IN or OUT of a building, area orfloor plan.
The system allows ‘USER’ setup and configuration of PORTALSwhich can be either outlined, shaded or invisible.
Clicking on the PORTAL can be configured to zoom IN and clickingoutside the PORTAL can be set to take you back OUT of any mapview.
Simultaneous AlarmsDatalog can handle simultaneous alarm events without the needfor operator intervention. The system offers 256 levels of priorityused for prioritising graphical displays, CCTV and other pre-determined events on alarm.
Help Instructions on AlarmA USER configurable help instruction can be pre-configured for allalarms, with alarm specific event instructions displayed for thealarm in focus. Help files can be edited and saved in either a TXTor RTF format.
Graphical Displays
Under normal non-alarm operation the mainscreen can be used to display either; the mainsite plan or a zoomed view of a more detailedbuilding or floor plan.
Zoom 1 - ActivationOn alarm activation the graphical display willautomatically zoom to layer 1, to detail thebuilding or floor plan and display the alarmicon(s) activated.
Zoom 2 - Detailed ViewOn ‘ACCEPT’ or if two or more simultaneousalarms are activated, a second zoom layer canbe used to display the alarms on a more detailedplan.
Intelligence in Software
Datalog security management softwareincludes a comprehensive range ofdatabase reports. Reports can be printed toscreen, printer or exported.
Alarm Analysis Reporting
Reports can be automatically generated andemailed at the end of day or month.
False Alarm Management
The Datalog Concept provides users with passwordprivilege, a range of reports that can be quicklysearched through the system database.
Comprehensive reports can be generated either in listor graphical format.
Reports include an alarm event analysis which can beeither manually or automatically generated. Alarmanalysis will search, correlate and collate information,to produce quick view graphs to identify trends andpatterns.
Virtual Walk Testing
Virtual walk testing will radically improvethe integrity of any alarm system. Thesoftware can continually check the statusfor all alarms monitored by the securitymanagement system.
A pre-alarm warning display is provided forall devices that have not changed state fora given time period. A further alarm can begenerated once a day every day, if achange in state has not been detected aftera grace period.
Virtual walk testing will help prevent circuitsthat have been by-passed, linked out,failed secure or have not been regularlytested.
ManagementReporting
HistoryDatabaseReport
AlarmAnalysisReport
Virtual WalkTestReport
Guard TourReport
InhibitReport
Group InhibitReport
CircuitListingReport
Faults &TampersReport
CustomReport
Sequential alarm monitoring software provides thecapability to manage more effectively alarms fromdifferent sources.
The software provides the capability to create‘AND and ‘OR’ relationships between differentsystems and detection types, combining them toprovide a more effective system that is resilient tofalse alarms.
Features include; automatic time zones forenabling individual or groups of detectors.Configured to chime only, switch cameras,enhance recording control and pre-alarm awarning, rather than create the unnecessary falsealarm that will undermine the system.
Guard Tour Software
Guard tour software can be incorporated using anyalarm monitoring input connected to the Datalogsystem as a ‘Tour Point’. Devices are secured andinhibited on route as the tour progresses, enablinga single person to patrol in safety and still monitora secure site.
On Screen Control
CCTV display with live on screen videoprovides the user with either touch or point andclick camera selection and PTZ control.
Software IntegrationDifferent manufacturers systems can be connected together by acombination of RS232, RS485, modems, dialup or networkedover a LAN or WAN.
Once connected panels appear transparent and act as oneintegrated system, offering a range of cause and effectpermutations for detection and verification of events.
Intruder
Fire
CCTV
Pager
Access
Building
Remote
Perimeter
Staff Safety
Intruder Alarm - Panel InterfaceDatalog offers the capacity to connect to arange of multiple intruder control panels.Panels set by RKP can be synchronised withcentral control for Area SET and UNSET.
On Screen Window ControlPanel emulation and custom window forms can be incorporated toprovide the user with unlimited on-screen controls.
Alarm and Output ControlOn screen ICONS can be configured to manually pulse or switchoutput relays/access doors/gates/barriers/bollards/lights/controls.
Closed Circuit Television SystemCCTV camera matrix controllers can be combined to be operatedfrom graphics screens. On-screen camera ICONS can be configuredto operate different systems seamlessly. Alarm events can beconfigured to switch cameras & presets across differentmanufacturers systems.
System Integration
Datalog offers a range of active on-screen ICONS for; CCTVcamera selection, display, PTZ control, access control, alarm outputswitching, panel emulation and custom events.
Choose Datalog 4 SMS for integrated security management systems withcritical performance applications requiring an extensive range of features
& system functionality.
Minimum Specification: IntelPentium 1000 MHz PC, 17”CRTMonitor, 10GB Hard Disk,128Mb Ram, 3.5inch 1.4MFDD,40+ Speed CD ROM, Windows98, 16bit Windows P&P AudioCard, Speakers, 102 keys (UKlayout) keyboard, 2 x 16550serial ports, 1 parallel port.
Datalog is supported by anetwork of International systemsuppliers.
Software can be remotelysupported. Requires installationof modem, modem software anduse of a suitable telephone line.
Choose Datalog 4 lite for applications where the need for a graphical userinterface does not require an extensive range of features and integration
capabilities for the lower budget applications.
Datalog 4 supports an ever increasing range of different manufacturers controlequipment, with an ongoing commitment to developing software for:-
Intruder Control PanelsPerimeter Fence Detection
CCTV Matrix, Switchers, Multiplexers, Digital Recorders, Remote Site MonitoringAccess ControlFire DetectionRadio PagingAsset Tagging
IntercomBuilding Monitoring
Staff Safety Systems
Security Management Systems - Intelligence in Software
Cortech Developments have a policy of continuous development and reserve the right to amend or alter any part of the product specification without notice. This literature is for general guidance only.All Trademarks and copyrights are recognised and acknowledged.
32 Bit Windows Compatible
Windows 98/NT/2K/XP
Individual Help Instructions
Large Alarm Capacity
Hundreds of Input/Output Groups
Time Zones
Single & Group Inhibit Timers
256 Levels of Priority
User Selectable Audio Wave Alarm Sounds
3 Graphic Zoom Levels
On-Screen Active Icons
Active Portals for Zooming In &Out of Maps
Active Portals for CCTV Pre-set Operation
Camera PTZ Icons
64 Password Levels
Password Validation Period
8 User Input/Output Group Inhibit Levels
Virtual Walk Testing
Guard Tour
User Defined Reset Reasons
Database Reports
Full Events Log
Archive Whilst Program Running
Master & Slaves
Custom Software Available
Panel Emulation
International LanguageTranslation
ISO9001 : 2000 Accredited
Datalog 4 Features Computer Hardware Technical Support
Laskey Farm, Laskey Lane, ThelwallCheshire WA4 2TF - 0044 (0)1925 750600