datasheet 5 reasons to specify simplex stancor oil...

2
BUILDING TRADES | CONSTRUCTION | MINING | UTILITIES | WASTEWATER 5 REASONS TO SPECIFY STANCOR OIL MINDER ® ENVIRONMENTALLY FRIENDLY WAY TO MANAGE WATER AND OILY LIQUIDS/HYDROCARBONS 5 Reasons Oil Minder ® Datasheet WWW.STANCORPUMPS.COM | 203.268.7513 OIL MINDER PRODUCT PORTFOLIO SIMPLEX A single-pump system allows users to cost effectively manage both water and hydrocarbons. The sensors ensure water is pumped while hydrocarbons are contained—and users are alerted to its presence. Stancor’s wide portfolio of pumps and customizable controls allows operators to build a system that is ideally suited to specific needs. Narrow floats can also be specified to accommodate space constraints. DUPLEX A two-pump system provides users redundancy for critical operations through a back-up pump or can be used to increase capacity for demanding applications. Alternating work allows pumps to last longer by evenly distributing wear. Specifying a two-pump system creates additional protection against liability and asset damage or loss. Duplex systems can be fully customized through Stancor’s comprehensive selection of pumps and customized controls. 1) a single-pump system that uses solenoid-based routing to send either water to the sewer or hydrocarbons to containment. 2) two separate pumps send water to the sewer or hydrocarbons to containment. LIQUIDATOR An engineered water/oil diversion system provides the ability to pump both water and hydrocarbons to separate locations. Users have two choices: © copyright 2016 Stancor, L.P.

Upload: others

Post on 24-May-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

BUILDING TRADES | coNSTRUcTIoN | mINING | UTILITIES | wASTEwATER

5 Reasons To specify sTancoR™ oil MindeR®enviRonMenTally fRiendly way To ManaGe waTeR and oily liquids/hydRocaRbons

5 Reasons oil minder® Datasheet

www.sTancoRpuMps.coM | 203.268.7513

oil MindeR pRoducT poRTfoliosiMplexA single-pump system allows users to cost effectively manage both water and hydrocarbons. The sensors ensure water is pumped while hydrocarbons are contained—and users are alerted to its presence.

Stancor’s wide portfolio of pumps and customizable controls allows operators to build a system that is ideally suited to specific needs. Narrow floats can also be specified to accommodate space constraints.

duplexA two-pump system provides users redundancy for critical operations through a back-up pump or can be used to increase capacity for demanding applications. Alternating work allows pumps to last longer by evenly distributing wear. Specifying a two-pump system creates additional protection against liability and asset damage or loss. Duplex systems can be fully customized through Stancor’s comprehensive selection of pumps and customized controls.

1) a single-pump system that uses solenoid-based routing to send either water to the sewer or hydrocarbons to containment.

2) two separate pumps send water to the sewer or hydrocarbons to containment.

liquidaToRAn engineered water/oil diversion system provides the ability to pump both water and hydrocarbons to separate locations. Users have two choices:

© copyright 2016 Stancor, L.P.

Layer of Oil

Layer of WaterLayer of Oil

Layer of WaterLayer of Oil

Layer of WaterLayer of Oil

Layer of Water

LargerLayer of Oil

Layer of Water

5 Reasons To specify oil MindeR oil MindeR sysTeM —how iT woRksStancor’s patented technology on conductive sensing, which measures the electrical current in a liquid and has proven to reliably differentiate oil and water, has been applied to a field base of more than 25,000 systems. Self-cleaning, conductivity probes are maintenance-free compared to optical sensors that attract contaminants.

Oil Minder’s plug-and-play, multi-pin connector offers: • assurance that the system is installed properly,

• utilization of certified UL components

• minimized labor when the system is installed and

• an efficient handoff between electrical and plumbing contractors. This system approach reduces both installation and inspection time

combining a full portfolio of pumps with the ability to customize controls allows Stancor to create solutions for individual needs. Providing a full package offers both flexibility, for a range of jurisdictional code interpretations, and the reliability/accountability associated from a single-system provider.

The Oil Minder system is designed to be both flexible and maintenance friendly. Running diagnostics from the accessible control panel allows users to test system performance without entering confined space. The “reset” button on the panel actuates alarm lights and turns the pump on to ensure proper installation.

The importance of reliability can’t be understated when components are placed into applications with life safety implications. As an example, Oil Minder’s high level alarm float offers additional reliability through redundancy in activating the system. And to ensure the highest level of quality, Stancor has contracted a third-party certification firm, Entela, to verify the entire system is manufactured to exacting specifications.

conducTivesensinG

cusToMizedsoluTion

push-To-TesT feaTuRe

pluG-and-play sysTeM

3Rd-paRTy ceRTificaTion

1

2

3

4

5

Layer of Oil

Layer of Water

Pump goes oN with water in contact with sensor probe.

Pump continues to pump down water.

Pump will continue to run, pumping water only until:• water level drops

below tip of sensor probe oR

• only oil is in contact with the sensor probe, eliminating electrical conductivity.

Pump shuts off before oil is pumped, leaving approximately 3” of liquid in bottom sump.

oil levels in the sump cause the sensor probe to switch the pump off (containing oil). If the water level in the sump increases, then the oil will rise above the oil sensing probe. This will cause the pump to turn back on and function in a normal manner until water is pumped down. oil will, once again, come in contact with the probe and the pump will stop.

Audible/visual alarms accompany pump activity. This ensures oil minder acts as an approved alarm system as specified in ASmE 17.1.

Pump On Pump On Pump On Pump On Float Up

Pump Off Pump Off Pump Off

Cover

Male Connector multi-pin connector and cord in conduit (lengths as required: 25 ft. standard and offered in additional 25 ft. increments).

PROBEPatented

www.sTancoRpuMps.coM