datasheet_kec115x_116x

Upload: kazishah

Post on 14-Oct-2015

25 views

Category:

Documents


0 download

DESCRIPTION

M ET ER

TRANSCRIPT

  • Norway - UK - Denmark www.megacon.com

    AC GENERATOR SHORT CIRCUIT AND OVER CURRENT GUARD

    Three phaseCurrentProtectionwithVATOR, Definite timeor Two levelO/C trip function

    PREDICTOR function, TheBlackoutPreventer

    Pathfinder function eases fault finding

    Independent ammeter with Full Load Current (FLC) mark onscale

    Triple relay operationgivesmore flexibility

    FastanaloguemAoutput (KEC116xversions)

    The digitally controlled true RMS measurement provides precision (1,0%) three phase currentprotection for AC generators, motors, transformers etc. for alarms or tripping of a non-essentialload orbreaker.

    The independent class 1,5 moving iron ammeter input (term. 26 & 27) be externally connected orswitched to read individual phase currents.

    MUST

    User settable trip levels and delays. LEDs flash during countdown and indicate the alarm status. The"Pathfinder" function identifies the phase causing the trip by the flashing pattern of the LED.

    KEC116x models have a fast response (

  • Innovation Beyond TraditionELECTRONIC CO NTR OL AND IN STRU M ENTAT ION

    KEC115E -KEC116EShort Circuit and OverCurrent VATOR GuardO/C VATOR and definite time S/C trip delays maintain discrimination betweenparallelled generators. The fail-safe relay R3 (O/C should be used toopen the generator breaker. R1 (S/C) and R2 (O/C) can be used for localindication, alarm systemorPM-Systemetc.All relays latch after trip.

    & S/C)

    Description Relay Operation

    AC GENERATOR SHORT CIRCUIT AND OVER CURRENT GUARD KEC115x/116x

    KEC115E2 -KEC116E2Short Circuit and OverCurrent VATOR GuardO/C VATOR and definite time S/C trip delays. R2 (O/C) and the fail-safe relayR1 (S/C) should be used to open the generator breaker. The common alarmrelay R3 (S/C & O/C) can be used for local indication, alarm system or PM-System etc.All relays latch after trip.

    KEC115F -KEC116FShort Circuit and OverCurrent Guard

    classic

    or

    Replaces the KEC115. Definite time O/C and S/C trip delays. Fail-safe S/C relay. All relays latch after trip. Either R1 (S/C) and R2 (O/C) can beused to trip generator breaker with R3 as a common alarm R3 can trip thegenerator breaker with R1/R2 used for local indication, PMS or alarm systeminput etc.

    KEC115F2 -KEC116F2Short Circuit and OverCurrent Guard

    orDefinite time O/C and S/C trip delays. Either R1 (S/C) and R2 (O/C) can beused to trip generator breaker with R3 as a common alarm R3 can trip thegenerator breaker with R1/R2 used for local indication, PMS or alarm systeminput etc. NON fail- safe latching relays. Since all relays are NON fail-safe thisversion is only suitable as a replacement for older installations.

    KEC115G -KEC116GShort Circuit and OverCurrent Guard

    emergency/harbour.

    For marine generator sets. Definite time O/C and S/Ctrip delays Non-latching O/C trip relay (R2) and non-failsafe S/C trip relay(R1). If an engine is set as an emergency generator only R1 (S/C) shall beused to open the generator breaker as per the requirements of classificationsocieties. In harbour operation both relay R1 and R2 shall open the breaker.R3 operates on both S/C and O/C and can be used for alarm systeminput etc.

    KEC115EKEC116E

    S/C O/C1

    O/C2

    FailSafe

    Latch DefiniteTime S/C

    DefiniteTime O/C

    VATOR Predictor

    R1 R2 R3

    KEC115E2KEC116E2

    S/C O/C1

    O/C2

    FailSafe

    Latch DefiniteTime S/C

    DefiniteTime O/C

    VATOR Predictor

    R1 R2 R3

    KEC115FKEC116F

    S/C O/C1

    O/C2

    FailSafe

    Latch DefiniteTime S/C

    DefiniteTime O/C

    VATOR Predictor

    R1 R2 R3

    KEC115F2KEC116F2

    S/C O/C1

    O/C2

    FailSafe

    Latch DefiniteTime S/C

    DefiniteTime O/C

    VATOR Predictor

    R1 R2 R3

    KEC115GKEC116G

    S/C O/C1

    O/C2

    FailSafe

    Latch DefiniteTime S/C

    DefiniteTime O/C

    VATOR Predictor

    R1 R2 R3

    Depending on application, select the model that matches the electrical installation. If none of the listed models fit your purpose please contact Megacon for customer adaptation.

    Page 2 of 4

  • Innovation Beyond TraditionELECTRONIC CO NTR OL AND IN STRU M ENTAT ION

    AC GENERATOR SHORT CIRCUIT AND OVER CURRENT GUARD KEC115x/116x

    KEC115H -KEC116HShort Circuit and 2-level Over Current Predictor Guard2-level O/C settings. Definite time O/C and S/C trip delays. Instead of theVATOR function the H-versions have 2 over current set trip levels to reduce triptime in high over load situations. "Predictor" early action on relays R1 and R2,both relays will trip after full set O/C S/C time. R3 is delayed and will trip afterfull set O/C time + 1sec S/C time +200mS. R3 is used to open the generatorbreaker. R1 or R2 are used for bus-tie breaker opening or for preference loadtripping.

    oror

    Description

    KEC115P -KEC116PShort Circuit, VATOR OverCurrentand PredictorGuardThe best choice for diesel electric systems to prevent totally black out. VATORO/C trip delay. Fail safe and latching R3. "Predictor" early action on relays R1and R2, R2 will trip after full set O/C and R1 after full set S/C time. R3 isdelayed and will trip after full set O/C time + 1sec S/C time + 200mS. R3 isused to open the generator breaker. R1 and/or R2 are used for bus tie breakeropening, preference load tripping, PMSor alarmsysteminputetc.

    or

    KEC115P2 -KEC116P2Short Circuit and OverCurrent GDefinite time O/C and S/C trip delays. Fail safe and latching R3. "Predictor"early action on relays R1 and R2, both relays will trip after full set O/C S/Ctime. R3 is delayed and will trip after full set O/C time + 1sec S/C time +200mS. R3 is used to open the generator breaker. R1 and/or R2 are used forbus tie breaker opening, preference load tripping, PMS or alarm system inputetc.

    oror

    Predictor uard

    KEC115P3 -KEC116P3Short Circuit and OverCurrent Predictor Guard (S/C only)Definite time O/C and S/C trip delays. Fail safe and latching R3. "Predictor"early action on relay R1 and R2, both relays will trip after full set S/C time. R3 isdelayed and will trip after full set O/C time + 1sec S/C time + 200mS. R3 isused to open the generator breaker. R1 and R2 are used for bus tie breakeropening, preference load tripping, PMSor alarmsysteminputetc.

    or

    KEC115HKEC116H

    S/C O/C1

    O/C2

    FailSafe

    Latch DefiniteTime S/C

    DefiniteTime O/C

    VATOR Predictor

    R1 R2 R3

    KEC115H5 -KEC116H5Short Circuit and 2-level OverCurrentPredictorGuard2-level O/C settings. Definite time O/C trip delays. "Predictor" early action onR1 and R2 , both relays will trip after full set O/C S/C time. R3 is delayed andwill trip after full set O/C time + 1sec S/C time + 200mS. R3 is used to openthe breaker. R1 is used for bus-tie breaker opening or for preference loadtripping.

    oror

    KEC115H5KEC116H5

    S/C O/C1

    O/C2

    FailSafe

    Latch DefiniteTime S/C

    DefiniteTime O/C

    VATOR Predictor

    R1 R2 R3

    KEC115H4 -KEC116H4Short Circuit and 2-level OverCurrentGuard2-level O/C settings. Definite time O/C and S/C trip delays. Instead of theVATOR function the H-versions have two over current set trip levels to reducetrip time in high over load situations. All relays will trip after full set time.Individual alarmrelay outputs give flexibility for a variety ofapplications.

    KEC115H4KEC116H4

    S/C O/C1

    O/C2

    FailSafe

    Latch DefiniteTime S/C

    DefiniteTime O/C

    VATOR Predictor

    R1 R2 R3

    KEC115PKEC116P

    S/C O/C1

    O/C2

    FailSafe

    Latch DefiniteTime S/C

    DefiniteTime O/C

    VATOR Predictor

    R1 R2 R3

    Relay Operation

    KEC115P2KEC116P2

    S/C O/C1

    O/C2

    FailSafe

    Latch DefiniteTime S/C

    DefiniteTime O/C

    VATOR Predictor

    R1 R2 R3

    KEC115P3KEC116P3

    S/C O/C1

    O/C2

    FailSafe

    Latch DefiniteTime S/C

    DefiniteTime O/C

    VATOR Predictor

    R1 R2 R3

    Depending on application, select the model that matches the electrical installation. If none of the listed models fit your purpose please contact Megacon for customer adaptation.

    Page 3 of 4

  • Company NO. 911198584Registered Address: vre Krkenes 17, N-5152 Bnes, Norway Innovation Beyond TraditionELECTRONIC CO NTR OL AND IN STRU M ENTAT ION

    ORDERING EXAMPLE:Type: KEC116PAux. Supply:Input Current CT:Range: 0-1,5/3kAAnalogue O/P: O/P 3:4-

    200-240V1500/5A

    20mA

    DIN96

    PANELCUTOUT92 x92mm

    1.25 to 8mmthick

    96mm

    89mm108mm

    121314151617181920

    22

    2130

    3132

    C o m po rt

    2627

    12

    3

    4

    5678910

    Analogue Output

    The has an analogue output proportional to the highest up ampere-meter reading. The signal is specifically intended as an input to a controlsystemfor ampere monitoring, load sharing, load shedding etc.

    Add suffix fromtable below to type designation to specify outputrequired:

    O/P1 O/P6O/P2 O/P7O/P3 O/P8O/P4 N/A O/P9O/P5 O/P10

    KEC116x

    0 - 10mA0 - 20mA4 - 20mA 0 - 10V

    0,2 - 10V4,3 - 20mA

    N/AN/A

    N/A

    Relay ResetAny latched relay is reset by linking terminals 30 and 31 or by interrupting thevoltage input to terminal 1.

    The MEGACON policy is one of continuous improvement, consequentlyequipment supplied may vary in detail from this publication.

    AC GENERATOR SHORT CIRCUIT AND OVER CURRENT GUARD KEC115x/116x

    Pathfinder FunctionWhen either short circuit or over current trips have operated the relevant LEDwill flash in the following pattern to indicate the phase producing the trip.

    VATOR function - Variable Time Over-current Release

    Release characteristic combining definite time and dynamic response tomaintain thermal capability protection and selective protection betweenparalleled generators.

    AmmeterInpu t

    Analogue O/P(Optional)

    22

    21

    L3 L2 L1

    1

    2

    3

    4

    26

    27

    5

    6

    10

    9

    8

    7

    12

    1716

    1514

    13

    1819

    20

    DCAux(Optional)32

    31

    30

    SUPPLY

    R1

    R3

    R2

    KEC115xKEC116x

    Reset

    +

    -

    +

    -

    Relays shown de-energised,a fail-safe relay energiseswhen the unit is powered.

    L1(R)L2(S)L3(T)

    Red indicates LED on

    100

    75

    Definitetime

    Definitetime

    8% of setdelay ormin 1sec

    50

    25

    8

    0 150 %Inom 200

    %of any

    settimedeley

    Over Currentrelease

    characteristic

    Page 4 of 4