dcs 408r | dcs 408r - texim italia · 2017. 10. 13. · dynacord | dcs 408r dcs 408r 5 line relays...
TRANSCRIPT
Dynacord | DCS 408R
DCS 408R
www.dynacord.com
▪ 5 line relays for 100 V, each with 2 switch contacts
▪ Pluggable connection terminals with screwed flangefor all contacts
▪ 5 relay control LEDs
▪ Configure the speaker distributor by separating thewire jumpers
▪ A maximum of 12 DCS 408R/409R relay modulescan be cascaded
The module is fitted on the back of the DCS 400 rackplug-in board. This is primarily used to switch 100-Vspeaker lines. However, the relays can also be used forall-call, forced reception, as an E or D relay, or forcontrol purposes.
Parts included
No. Component
1 DCS 408R
2 Plug, 15-pin (Phoenix MC 1.5/15-STF-3.81 - 1827839)
Technical specifications
Operating voltage 24 V DC, -10%/+30%
Operating current, relays off
• Standby 24 V, 5.5 mA, 0.14 W
• Idle/Announcement/Alert 24 V, 96 mA, 2.31 W
Electromagnetical environment E1, E2, E3
Operating temperature -5 °C to 45 °C
Product dimensions (Width byHeight by Depth)
37.5 by 80.6 by 245 mm
Net weight 225 g
Relay contacts
• Contacts 2 SPDT
• Contact material AgNi 90/10
• Contact load (real) 2000 VA
• Contact current 8 A
• Switching voltage 100 V AC
P/S ID
+24V
+24V
+24V
RelayDriverS/P
+24V
RES
EN 3
EN 2
DATA2
DATA1_A
CLK1
RES_A
EN 3_A
EN 2_A
DATA2_A
DATA1
CLK1_A
A14
B29
A13
A15
B28
B30
A11
B26
A10
A12
B25B27
A8
B23
A7
A9
B22
B24
A5
B20
A4
A6
B19
B21
A2
B17
A1A3
B16B18
t
DCDC
+5V
CN
to B
ackp
lane
CLK2
CLK2_A
CLK3
CLK3_A
*RES
*RES_A
DATA3_A
DATA3
DATA4_A
DATA5
DATA5_A
DATA_SEL
DATA_SEL_A
EN1
EN1_A
EN4
EN4_A
EN5
EN5_A
EN6
EN6_A
EN7
EN7_A
EN8
EN8_A
MON+
MON-
BR1BR2BR4BR3
BR5BR6BR8BR7
BR9BR10BR12BR11
BR13BR14BR16BR15
S2S1
+24V
+24V
Block diagram
Installation/configuration notes
Installation informationOn the DCS 400 rack plug-in board, slots 1–10 mustbe occupied in ascending sequence (left to right)without any gaps. Different module types canotherwise be arranged in any sequence.Exception: Slot 1 (far left) must always be occupiedwith a DCS 801R control module or DCS 405Rextension module.When assembling the device and installing theconnections, please comply with the standards VDE0100 and EN 60065.
ConnectorThe scope of delivery for the device includes two 15-pin connectors. Conductor cross-sections of 0.14 mm²(AWG26) to 1.5 mm² (AWG16) can be used.Recommended connecting cable: flexible CU strand,LiY, 0.75 mm².
Position of the bridges on the circuit board
Certifications and approvals
Status as of November 2012:• EN 50130-4• EN 54-16• EN 55103-1• EN 55103-2
Ordering information
DCS 408ROrder number F01U121784
2 | DCS 408R
Represented by:
Germany: EVI Audio GmbHSachsenring 6094315 StraubingGermany
www.dynacord.com
© Bosch Security Systems 2013 | Data subject to change without noticeDocument Number | Vs1 | 19. Mar 2013