Altech is an “ISO 9001-2008 certified”, “IBR” & “PESO (CCOE)” approved and “ASME U Stamp” holder, state-of-the-art production facility, conveniently located at Chopanki (Bhiwadi)-Rajasthan, India, 60 kms from Delhi, assists us in assuring Quality, Efficiency, Reliability of our Products and Timely Completion of our Orders.CONTACT US :[email protected]

TRANSCRIPT

Page 1: DEAERATORS
Page 2: DEAERATORS

Why Deaeration

• Feedwater temperature

• Feed water ph value

• Feedwater oxygen content

Corrosion of iron or steel in boilers or boilers feed water piping is caused by three fundamental factors

Page 3: DEAERATORS

Deaerator Principles

There are

Deaeration is the mechanical removal of dissolved gases from the boiler feedwater.

principles that must be met in the design of any deaerator.

Page 4: DEAERATORS

Deaerator Principles

The incoming feedwater must be heated to the full saturation temperature, corresponding to the steam pressure maintained inside the deaerator . This will lower the solubility of the dissolved gases to zero.

Page 5: DEAERATORS

Deaerator Principles

The heated feedwater must be mechanically agitated. This is accomplished in a tray deaerator by first spraying the water in a thin film into a steam atmosphere. Creating a thin film reduces the distance the gas bubble has to travel to be released from the water. Next, the water is cascaded over a bank of slotted trays, further reducing the surface tension of the water. This allows for the removal of any gases not liberated by the initial spraying.

Page 6: DEAERATORS

Deaerator Principles

Adequate steam supply must be passed through the water, in both the spray section and the tray section to sweep out the gases from the water.

Page 7: DEAERATORS

Using Henry’s law of partial pressures, the principle behind Deaeration can be explained

Page 8: DEAERATORS

The quantity of a gas dissolved in a given quantity of liquid is directly proportional to its partial pressure surrounding the liquid.

Therefore, by reducing the partial pressure of the unwanted gasses in the surrounding atmosphere, the gasses are diminished.

These partial pressures are reduced by spraying the liquid into a counter current flow of steam.

Page 9: DEAERATORS

The steam, which is free of non-condensable gasses, is the liquid’s new atmosphere and Henry’s law prevails.

Using steam is advantageous in that the solubility of a gas in a liquid decreases with an increase in the temperature of that liquid.

The liquid is sprayed in thin films in order to increase the surface area of the liquid in contact with the steam, which, in turn, provides more rapid oxygen removal and lower gas concentrations.

Page 10: DEAERATORS

With these principles in mind, Sterling Deaerator employs a two-stage system of heating and deaerating feedwater

Page 11: DEAERATORS

This system reduces oxygen concentration to less than 0.007 ppm, and

completely eliminates the carbon dioxide concentration when tested by the APHA method.

Testing for oxygen concentration shall be done in accordance with ASME Performance Test Code 12.3.

Page 12: DEAERATORS

DE

AE

RA

TO

R

PERATIONS

Page 13: DEAERATORS

FIRST STAGE OF DEAERATION

Page 14: DEAERATORS

Deaerator Operation - STAGE 1

The prime element in our vent condenser zone is the self-adjusting spray valve that allows incoming water, which is to be deaerated, to discharge as a thin-walled, hollow cone spray (See Figure IA)..

Because steam flows countercurrent, intimate water to steam contact occurs with consequent latent heat transfer.

As the falling water reaches the tray stack (tray type Deaerator), or the collection basin (spray type Deaerator), its temperature is within 2°F (1ºC) of the counter-flowing saturated steam temperature.

Page 15: DEAERATORS

Deaerator Operation - STAGE 1

Most of the dissolved oxygen and free carbon dioxide have been removed at this point.

Since nearly all of the steam has been condensed, the non-condensable gasses and the small amount of “transport” steam exits through the vent piping

Page 16: DEAERATORS

Deaerator Operation - STAGE 2

The partially deaerated water enters the tray stack at saturation temperature.

The heated water flows down over the trays, zigzagging as shown in Figure IB through counter flow steam.

This arrangement provides additional retention time to allow a final oxygen strip by the purest steam.

Page 17: DEAERATORS

Deaerator Operation - STAGE 2

The two-stage tray deaeration technique is the most reliable method for meeting critical performance over a complete load range.

Page 18: DEAERATORS

Deaerator Operation - STAGE 2

Water from the collection basin flows down the vertical down comer and into the scrubber section where it comes in contact with upcoming steam.

Through carefully sized orifices, the steam and water violently mix, heating and removing the remaining gasses from the water.

The mixture moves to the top of the scrubber housing and there the steam separates from the water and gasses and continues to flow up into the spray area and the vent condensing zone (Stage One of our Deaerator). See Figure I.

Page 19: DEAERATORS

Deaerator Operation - STAGE 2

Water from the collection basin flows down the vertical down comer and into the scrubber section where it comes in contact with upcoming steam.

Through carefully sized orifices, the steam and water violently mix, thus setting off heating and flashing of the water as it propels the mixture to the top of the scrubber housing.

At this point steam separates from the mixture and continues to flow up into the vent condensing zone, or Stage One of our Deaerator. See Figure I.

Page 21: DEAERATORS
Page 22: DEAERATORS
Page 23: DEAERATORS

10

12

11

10

98

77

9

6

56

2

441

3

6

3

1 Feedwater Storage Tank

2 Deaerator

3 Liner Plates

4 Liner Plates

5 Platform & Ladder

6 Vent Piping

7Globe Valve, Stud B/2N &

Gasket

8 Vent Orifice

9Vent Silencer Support, Hex

B/N

Vent Silencer

Safety Relief Valve

Outlet Piping, Stud B/2N & Gasket

10

11

12

Page 24: DEAERATORS

STERLING

MODELS

Page 25: DEAERATORS

Model HT

Horizontal Type With No Storage Capacity. Spray/Tray Technology

Page 26: DEAERATORS

Model VT

Vertical Type With No Storage Capacity. Spray/Tray Technology

Page 27: DEAERATORS

Model DT

Dome Type With Horizontal Storage. Spray/Tray Technology

Page 28: DEAERATORS

Model VTHS

Vertical deaerator horizontal storage. Spray/Tray technology

Page 29: DEAERATORS

Model HTHS

Horizontal deaerator with horizontal storage. Spray/Tray type

Page 30: DEAERATORS

Model DS

Dome type with integral horizontal storage. Spray/scrubber technology

Page 31: DEAERATORS

Model HS

Horizontal type with integral horizontal storage. Spray/scrubber technology

Page 32: DEAERATORS

Model UT

Upright with integral storage. Spray/tray technology

Page 33: DEAERATORS

Plot No.293,Kehar Singh Estate West end Marg, Opp.”D” Block Saket, Saidula Jab, New Delhi-110030