  • PV system layout

    SOLIVIA PV Planner - PV system layout 1

    CUSTOMER MANUFACTURER

    Mr. Anant ;

    Delta Energy Systems (Germany) GmbHSupport E-Mail: [email protected]

    INSTALLATION LOCATION CONFIGURATION CONDITIONS

    Mr. ;

    Min. Module temp.: -10CMax. Module temp.: +70CDimensioning temp.: +25CPower Ratio (DC/AC): 100% (100% effective)cos(?): 1.00

    SYSTEM SUMMARY

    PV-Generator total DC-power: 15.15 kWp Inverter AC nominal power: 15 kVA

    SYSTEM MODULES INVERTER ELECTRIC METER PUBLIC GRID

    1

    3x20 Sillia VL 60P250 1xSOLIVIA 15 TL (1 MPPT)

    3 ~

    15 kVA

  • SOLIVIA PV Planner - PV system layout 2

    System 11 x Delta Energy Systems SOLIVIA 15 TL (1 MPPT)TECHNICAL DATA INVERTERMax. recommended PV power 19 kWpNominal DC power 15.30 kWMPP voltage range 350 ... 800 VMax. DC current 48 ANominal AC power 15 kVA

    Your PV array

    DC POWER MPPT 1 MPPT 2 MPPT 3Power of PV array 15.15 kWpPower ratio: DC/AC 101.00 %DC VOLTAGEMPP Voltage (at 14 F) 682.02 VMPP Voltage (at 158 F) 520.61 VMPP Voltage (at 77 F) 611.40 VOpen circuit voltage (at 14 F) 839.08 VDC CURRENTMPP current (at 77 F) 24.78 AShort circuit current (at 158 F) 25.34 ADC CABLINGMaterial / Cable cross section Copper / 12 AWGSimple cable length 2,160 inAdd string combiner box (SCB) No

    Total DC cable loss 120.82W / 0.80%

  • SOLIVIA PV Planner - PV system layout 3

    Total System

    AC GRID CONNECTION L1 L2 L3Power per phase 5 kVA 5 kVA 5 kVAUnbalanced Load 0 kVACurrent 21.74 A 21.74 A 21.74 AGrid voltage 230 V 230 V 230 V

    AC CABLINGMaterial / Cable cross section Copper / 10 AWGSimple cable length 0 inVoltage drop 0 VPower loss 0 W