    Design Data Pertaining to the work of :

    Construction of HLB across Masi Vagu on Narayanapuram to Mittapalliroad at KM 10/800 in Yellandu Mandal of Khammam District.

    Under Tribal welfare Department

    Reference to Administrative Sanction : - G.O Ms No. ..

    For Rs. 00 Lakhs.

  • 7/29/2019 Design Proforma Amd

    2/5

    1. Hydraulic Data :-

    1. Type of crossing = Normal

    2 Design Discharge = 1120.37 cum / sec

    3. MFL = +100.000 M

    4. Sill Level = + 93.500

    5. Velocity of flow = 1.408 m/sec

    6 Afflux = 0.15

    7. Vertical clearance = 1.20 M

    8. Silt Factor, Ksf = 2.00

    9. Normal Scour depth, dsm = 7.5 m (MFL-Soft rock level)

    10. Foundation Levels = Soft rock level -1.5m

    For piers = + 91.000 mFor abutments = + 91.000 m

    10. L.W.W and Vents Provided :-

    1. L.W.W required = 80 M

    2. Vent Way Provided = 5 Vents of 16.5 m (eff) without footpaths

    3. Length of bridge (Back to Back of abutments) = 86.23 m(5*17.07+6*.03+2*.35= 86.23 m)

    11. Foundation Strata, SBC and Type of foundations adopted:-

    Soft Rock/SDR is available at a shallow depth of 1.0 m below sill level as per

    excavation carried at site for piers and abutments. The SBC considered is

    25.0 t/m2. Open Foundations are adopted.

  • 7/29/2019 Design Proforma Amd

    3/5

    Piers

    Open foundations in VCC M 15 are provided duly fixing the foundation level

    with 1.5 m embedment in SDR/Soft Rock

    Abutments:

    Open foundations in VCC M 15 are provided duly fixing the foundation level

    with 1.5 m embedment in SDR/Soft Rock

    Wing Walls: Box wings in VCC M 15 are proposed.

    12. Foundation Levels and strata of resting:-

    All the Piers = (+) 91.000 (resting in SDR/SR)

    Abutments A1, A2 = (+) 91.000 (resting in SDR/SR)

    13. Substructure:-

    Abutments: Wall type abutments in VCC M 15 mix with skin reinforcement.

    Piers: Wall type piers in VCC M 15 mix with skin reinforcement.

    Wingwalls: Box wings in VCC M 15 mix with skin reinforcement.

    14. R.C.L Calculations:-

    MFL = + 100.0

    V.C = 1.2

    Afflux = 0.15Deck Th. = 1.675

    Wearing coat = 0.100

    +103.125 M

    Bearings:- Neoprene Rubber bearings of size 630X220X061 mm.

  • 7/29/2019 Design Proforma Amd

    4/5

    15. Type of Superstructure and Drawings adopted) :

    RCC T beam girder and RCC slabs of 16.5 m (eff) span , without footpaths areprovided as per MOST BD drawing Nos. BD / 13-76,14-76A,15-76A.

    16. Expansion Joints :- Single Strip Seal Expansion Joints of standardmake

    17. Wearing Coat :- As per BD drawing No. BD / 1- 69 A in VRCC M

    30.

    Thickness = 100mm at center and 50mm at edges

    18. Approach Slabs :- As per CE drawing No. 4- 71 in VRCC M30

    Length = 4.0m, Width = 7.5m, Thickness =0.30m

    12. Hand Rails: As per drawing no. BD / 5-69 , type II in RCC M20

    13. Data adopted from Standard Superstructure drawings for Design Purpose

    Drawing Nos. referred (without footpaths)

    1. BD/13-76

    2. BD/14-76A

    3. BD/15-76A

    Dead Load :

    @ Pier = 174 T @ Abutment = 87 T

    Live Load :

    LL = (DL+LL) - DL

    @ Pier = 82.25 T @ Abutment = 70.0 T

    Concrete Quantity / Span: 61.2 cum

    Steel Quantity / Span :

    (ii)Reinforcing steel: 10.373 T(Including 5 % extra for wastage and laps)

  • 7/29/2019 Design Proforma Amd

    5/5

    Design Procedure adopted

    1. Substructure including foundations :

    Abutments and their foundations: Abutment: Wall type in VCC M 15 concrete

    with open foundations is designed as per IRCcodes for 2 lanes.

    Piers and their foundations: pier: Wall type in VCC M15 with open foundationsis designed as per IRC codes for 2 lanes.

    Wing walls and their foundation: Box wing wall in VCC M15 with open

    foundations as per IRC codes.

    Bed blocks over abutments and piers: Computer MS EXCEL program is used for

    design of Bed block over abutment.

    Backing walls: Computer MS EXCEL program is used for design of backing wallover abutment.

    Live Load eccentricity calculations

    (As per BD drawings of MORTH)

    Transverse:-

    (7.5/2) - ( 1.2 + (2.79/2) )

    = 1.155m

    Longitudinal: .285+.015

    = .3 m