DEVELOPMENT OF VERY LOW THRESHOLD DETECTION SYSTEM FOR LOW-BACKGROUND EXPERIMENTS Akimov D.Yu. 1 , Akindinov A.V. 1 ,Alexandrov I.S. 1 , Belov V.A. 1 , Burenkov A.A. 1 , Danilov M.V. 1 , Kobyakin A.S. 1 , Kovalenko A.G.. 1 , Roudik D.G. 1 , Stekhanov V.N. 1 Bondar А.Е. 2 , Buzulutskov А.F. 2 Bolozdynya А.I. 3 , Kirsanov М.А. 3 1Institute for theoretical and experimental physics 2 Budker Institute of Nuclear Physics Novosibirsk, Russia 3National Research Nuclear University "Moscow Engineering Physics Institute» 1 International Workshop on New Photon-detectors 2012 Presented by Ivan Alexandrov

Upload: fox

Post on 15-Feb-2016

51 views

Category:

Documents


0 download

DESCRIPTION

International Workshop on New Photon-detectors 2012. Development of very low threshold detection system for low-background experiments. Presented by Ivan Alexandrov. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Development of very low threshold detection system for low-background experiments

1

DEVELOPMENT OF VERY LOW THRESHOLD DETECTION SYSTEM FOR LOW-BACKGROUND EXPERIMENTS

Akimov D.Yu.1, Akindinov A.V.1,Alexandrov I.S.1, Belov V.A.1, Burenkov A.A.1, Danilov M.V.1 , Kobyakin A.S.1, Kovalenko A.G..1, Roudik D.G. 1, Stekhanov V.N.1

Bondar А.Е.2, Buzulutskov А.F.2

Bolozdynya А.I.3, Kirsanov М.А.3

1Institute for theoretical and experimental physics2 Budker Institute of Nuclear Physics Novosibirsk, Russia3National Research Nuclear University "Moscow Engineering Physics Institute»

International Workshop on New Photon-detectors 2012

Presented by Ivan Alexandrov

Page 2: Development of very low threshold detection system for low-background experiments

XE DETECTORS FOR “DARK MATTER” EXPERIMENTS

Xenon10,100 at Gran Sasso

ZEPLIN III at Boulby mine

XMASS at Kamioka

LUX at DUSEL

All detectors utilizes PMTs for detection of the LXe VUV light.

At present, PMTs (even low-background) are the most radioactive elements of detector.

Search for a replacement of PMTs for the future detectors is actual.

2

Page 3: Development of very low threshold detection system for low-background experiments

3

Matrix MRS APD

P M T

P M T

• Small size• Made from clean materials• no high voltage

MRS APD:

PMT MRS APD + WLS+THGEM

P M T

Some advantages of MRS APD:

Page 4: Development of very low threshold detection system for low-background experiments

MULTIPIXEL AVALANCHE GEIGER PHOTODIODE

-Voper

Readout

Structure of 1 cellScheme of MRS APD

View of matrix cells4

Page 5: Development of very low threshold detection system for low-background experiments

MULTIPIXEL AVALANCHE GEIGER PHOTODIODE

CPTA “green” – blue, green, IR CPTA “blue” – blue, green, IR

Typical PDE for CPTA 2x2 mm2

Charge: Q = e*Ncell*C*(U - Ubr)Multiplication: M = C*(U - Ubr)

Photon Detection Efficiency:PDE= Q.E.*RG*ε geom

5

Page 6: Development of very low threshold detection system for low-background experiments

6

Wave Length Shifter in liquid xenon

1- emission of LXe, 2 – absorption p-terphenil, 3 – emission of p-terphenyl, 4 – range of sensitive MRS APD

Page 7: Development of very low threshold detection system for low-background experiments

7

FIRST TESTS. RESULTS

Construction of WLS Ncells PDE ,%Р-terphenyl encapsulated by

saphfire window 24±0.59.7±1.2

Р-terphenyl cowered by poly-para-xylynen film 72±1.5

8.4±1.1

P. Benetti, et al., Nucl. Instr. Meth. A505, 89 (2003).For a blue sensitive PMT (QE ≈20%) with WLS: ~ 10%

Page 8: Development of very low threshold detection system for low-background experiments

8VUV PMT

Cathode (Grid)

Anode (mirror)

Liquid nitrogen

Level LXe

Anode (THGEM)

WLSMRS APD

Cathode

Diameter THGEM (50 mm) less than diameter LXe chamber (106 mm)

LXe chamber

vacuum

Single THGEM Experimental setup

Page 9: Development of very low threshold detection system for low-background experiments

9

THGEM principle of operation Electric field in GEM

Photos of GEM

Scheme of photo detector based on GEM

GEM

Light

Anode

A unique property of GEMs, as compared toother micro-pattern detectors, is their capability tooperate in cascade

Page 10: Development of very low threshold detection system for low-background experiments

10

THGEM

WLS (p-terphenyl covered by poly-para-xylylen on saphiire) + grid

Step - 0.7 mm, Diameter - 0.4 mm, thickness - 0.25 mm

MRS APD (CPTA)

2 mm

2 mm

Experimental setupMatrix MRS APD

Matrix MRS APD+ WLS

Page 11: Development of very low threshold detection system for low-background experiments

11

UTHGEM = 1.6 kV UTHGEM =1.8 kV

UTHGEM = 2.0 kV

FIRST RESULT

Dependence electroluminescence in THGEM on Δ U

9 mm

5 mm

22 mm

Sum signal matrix PMT

Sum signal matrix MRS APD

Page 12: Development of very low threshold detection system for low-background experiments

SECOND TEST RUN (DOUBLE GEM)

2nd THGEM1st THGEM

Sum signal matrix MRS APD

Sum signal matrix PMT

Electroluminescence from 2nd THGEM dependence on Δ U

For field in

For field in liquid 2.5 kV/cm and in gas 4.90 kV/cmArea corresponds to 5950 ph.e. and 850 e (7 ph.e./e.)

For THGEM2 U=1.6 kVMRS APD array signal ~150 cells

~300 for THGEM2 U=2.1 kVFor 1V overvoltage ->3% PDE (MRS APD +WLS) Fill factor for array ~6% -> 50%So, it can be increased by a factor of 60, i.e. ~9000 cells

~ 10 cells/eCan be achieved.

Page 13: Development of very low threshold detection system for low-background experiments

13

SECOND TEST RUN (DOUBLE GEM)Reconstruction of muon track by

PMT Matrix MRS APD Matrix

0.19 mm 0.036 mm

Page 14: Development of very low threshold detection system for low-background experiments

14

MONTE CARLO SIMULATION (GEM)Matrix PMT .

Radius PMT. Radius SiPM.

Y, mm

X, mm X, mm

Y, mm Matrix MRS APD .

Radius MRS APD

Radius of model event, mm Radius of model event, mm

Radius of the event is determined by a centroid

Radius of the event is determined by a centroid

Page 15: Development of very low threshold detection system for low-background experiments

15

Large-size WLS plate with protection layer was tested successfully in Xe (electron life time seems O’k ) THGEMS were tested in pure XeThe estimated single electron signal is ~10

cells for 50 % fill of array and full PDE

Conclusion

Page 16: Development of very low threshold detection system for low-background experiments

16

Backup

Page 17: Development of very low threshold detection system for low-background experiments

17

ESTIMATION OF FIRED CELL NUMBER PER SINGLE IONIZATION ELECTRON EXTRACTED

FROM LIQUIDFor THGEM2 U=1.6 kVMRS APD array signal ~150 cells

~300 for THGEM2 U=2.1 kVFor 1V overvoltage ->3% PDE (MRS APD +WLS) Fill factor for array ~6% -> 50%So, it can be increased by a factor of 60, i.e. ~9000 cells

For field in liquid 2.5 kV/cm and in gas 4.90 kV/cmArea corresponds to 5950 ph.e. and 850 e (7 ph.e./e.)

~ 10 cells/eCan be achieved.

Page 18: Development of very low threshold detection system for low-background experiments

18

Pulse area, V·ns

CPTA “blue”

PMT

SPECTRUMS

шум

α пик

1 ячейка

2 ячейка

пьедестал

Положения а пика 1 вариант 27 ячеек

2 вариант 84 ячейки

Page 19: Development of very low threshold detection system for low-background experiments

19

ФЭУ GPIB

I VI

III

II

IV

VVII

Блок выработки триггера

Предуси-лители

Усили-тели

Tektronix 625 MHz

LeCroy LT344 500 MHz

Триг

-гер

VME

200 MHz FADC

SiPM 1-U1

-U19

SiPM 19

-U

Блок питания

Блок усилителей

200 MHz FADC 8 каналов

V2718 VME – PCI контроллер

2 блока ADC VME-V1720 (16 каналов)

Схема электроники

Page 20: Development of very low threshold detection system for low-background experiments

20

РЕЗУЛЬТАТЫ & ВЫЧИСЛЕНИЕ ЭФФЕКТИВНОСТИ

84 ячейки

Page 21: Development of very low threshold detection system for low-background experiments

21

SECOND TEST RUN (DOUBLE GEM)