diamond ii+annubar primary flow element - åf · pdf filediamond ii+annubar® primary...
TRANSCRIPT
Product Data Sheet 00813-0100-4760, DS-4009
Flow-375
Diam
ond
II+An
nuba
r®
Diamond II+Annubar ® Primary Flow Element
THE DIAMOND II+ANNUBAR ® PRIMARYFLOW ELEMENT HAS PROVEN TO BEACCURATE AND RELIABLE IN HUNDREDSOF THOUSANDS OF APPLICATIONS.
ACCURATE
• Annubar primary flow element design
• Long-term accuracy
SENSIBLE
• Energy cost savings
• Low installation costs
ADAPTABLE
• No system shutdown
• Special materials
• Gear drive
• Special flow element models and designs
• Pak–Lok®
• Elbow mounting
• Bi-directional flows
• Integral manifold head
• Integral valve head
• Integral temperature sensor
COMPLETE POINT SOLUTIONS™
Complete Point Solutions provides fully engineered measurement solutions, combining best product and practices for improved performance, reliability, and cost of ownership.
The capability of the world’s finest industrial measurement instrumentation is further increased by combining it with a premier offering of complimentary products. This system is engineered and assembled by Rosemount Inc. to make it easy for you to specify and order the correct equipment for your process measurement needs.
We complement our field instruments with a wide range of technologies; including, manifolds, primary elements, process flanges and seals, and temperature sensors and accessories.
Complete Point Solutions is designed to provide you with Best-in-Class equipment — allowing you to save on installation costs, and improve the reliability and capability of your process.
Take advantage of our vast experience in process measurement, and start improving your process with Complete Point Solutions.
Flow-376
Diamond II+ Annubar®
Diamond
II+Annubar®
D i a m o n d I I + A n n u b a rP r i m a r y F l o w E l e m e n t
DIAMOND II+ ANNUBAR PRIMARY FLOW ELEMENT - - - - - 379DRAMATICALLY REDUCEINSTALLATION AND
OPERATINGCOSTS - - - - - - - - - - - - - - - - - - - - - - - - - - - 379MOUNTING CONFIGURATIONS- - - - - - - - - - - - - - - - - - - - 379
Design Pr incip les
DIFFERENTIAL PRESSUREFLOW MEASUREMENT - - - - - - - - - - - - - - - - - - - - - - - - - 380HOW IT WORKS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 380
Per formance
THE DIAMOND II+ SENSOR- - - - - - - - - - - - - - - - - - - - - - 382
Benef i ts
ENERGY SAVINGS - - - - - - - - - - - - - - - - - - - - - - - - - - - - 384OPERATINGCOST SAVINGS- - - - - - - - - - - - - - - - - - - - - - 384INSTALLATION COST SAVINGS - - - - - - - - - - - - - - - - - - - 384ELBOW-MOUNTED ANNUBARPRIMARY FLOW ELEMENT - - - - - - - - - - - - - - - - - - - - - - 385
Features
DESIGNED-IN ACCURACY - - - - - - - - - - - - - - - - - - - - - - - 386ENERGY COST SAVINGS - - - - - - - - - - - - - - - - - - - - - - - - 386INSTALLATION COST SAVINGS - - - - - - - - - - - - - - - - - - - 386CHOOSE THEMODELADAPTED FOR YOUR APPLICATION - - - - - - - - - - - - - - - - 386SPECIAL MODELS AND DESIGNS - - - - - - - - - - - - - - - - - - 387
Ins tal lat ion
ORIENTATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 388LOCATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 388
Siz ing and How To Order
1. CHOOSE AMOUNTING METHOD- - - - - - - - - - - - - - - - - 3892. CHOOSE ASENSORSIZE - - - - - - - - - - - - - - - - - - - - - - 3903. VERIFY MODEL AND SENSORSIZE - - - - - - - - - - - - - - - 3914. CHOOSE THEMODEL OPTIONS- - - - - - - - - - - - - - - - - - 3935. VERIFY PROCESS ANDPIPE INFORMATION - - - - - - - - - - 394
Ordering In format ion—Model DCR
MODEL DCR+15S/16S - - - - - - - - - - - - - - - - - - - - - - - - 395MODEL DCR+25S/26S - - - - - - - - - - - - - - - - - - - - - - - - 397MODEL DCR+35S/36S - - - - - - - - - - - - - - - - - - - - - - - - 400MODEL DCR+45S/46S - - - - - - - - - - - - - - - - - - - - - - - - 403
Rosemount Inc.
Flow-377
Diam
ond
II+An
nuba
r®
D i a m o n d I I + A n n u b a rP r i m a r y F l o w E l e m e n t
Ordering In format ion—Model DFF
MODEL DFF+15S/16S - - - - - - - - - - - - - - - - - - - - - - - - -409MODEL DFF+25S/26S - - - - - - - - - - - - - - - - - - - - - - - - -411MODEL DFF+25H/26H - - - - - - - - - - - - - - - - - - - - - - - - 414MODEL DFF+25M/26M - - - - - - - - - - - - - - - - - - - - - - - - 417MODEL DFF+35S/36S - - - - - - - - - - - - - - - - - - - - - - - - -420MODEL DFF+45S/46S - - - - - - - - - - - - - - - - - - - - - - - - -423MODEL DFF+45H/46H - - - - - - - - - - - - - - - - - - - - - - - - 426MODEL DFF+45M/46M - - - - - - - - - - - - - - - - - - - - - - - - 428
Ordering In format ion—Model DPF
MODELS DPF+15S/16S - - - - - - - - - - - - - - - - - - - - - - - - 434MODELS DPF+25S/26S - - - - - - - - - - - - - - - - - - - - - - - - 436MODELS DPF+35S/36S - - - - - - - - - - - - - - - - - - - - - - - - 438MODELS DPF+45S/46S - - - - - - - - - - - - - - - - - - - - - - - - 440
Ordering In format ion—Model DNT
MODEL DNT+10S- - - - - - - - - - - - - - - - - - - - - - - - - - - - 446
Ordering In format ion—Model DNF
MODEL DNF+10S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 447MODEL DNF+10H - - - - - - - - - - - - - - - - - - - - - - - - - - -449MODEL DNF+10M - - - - - - - - - - - - - - - - - - - - - - - - - - -450
Ordering In format ion—Model DNW
MODEL DNW+10S - - - - - - - - - - - - - - - - - - - - - - - - - - -451
Ordering In format ion—Model DMT
MODEL DMT+15S - - - - - - - - - - - - - - - - - - - - - - - - - - -456MODEL DMT+25S - - - - - - - - - - - - - - - - - - - - - - - - - - -458MODEL DMT+35S - - - - - - - - - - - - - - - - - - - - - - - - - - -461
Ordering In format ion—Model DHT
MODEL DHT+15S- - - - - - - - - - - - - - - - - - - - - - - - - - - - 469MODEL DHT+25S- - - - - - - - - - - - - - - - - - - - - - - - - - - - 471MODEL DHT+35S- - - - - - - - - - - - - - - - - - - - - - - - - - - - 474
Ordering In format ion—Model DHF
MODEL DHF+15S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 482MODEL DHF+25S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 485MODEL DHF+25H - - - - - - - - - - - - - - - - - - - - - - - - - - -488MODEL DHF + 25M - - - - - - - - - - - - - - - - - - - - - - - - - - 491MODEL DHF+35S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 494MODEL DHF+45S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 497MODEL DHF+45H - - - - - - - - - - - - - - - - - - - - - - - - - - -500
Spec i f icat ions
FUNCTIONAL SPECIFICATIONS- - - - - - - - - - - - - - - - - - - -509PERFORMANCESPECIFICATIONS- - - - - - - - - - - - - - - - - - - 509PHYSICAL SPECIFICATIONS- - - - - - - - - - - - - - - - - - - - - - 510
Flow-378
Diamond II+ Annubar®
Diamond
II+Annubar®
D i a m o n d I I +
A N N U B A R ®
P r i m a r y F l o wE l e m e n t
-379
Diam
ond
II+An
nuba
r®
Flow
DIAMOND II+ANNUBARPRIMARY FLOW ELEMENT
The Annubar® primary flow element has proven to be accurate and reliable in hundreds of thousands of applications. The Diamond II+ Annubar primary flow element is designed to give the highest performance of any differential pressure device.
The flow element operates by sensing an impact pressure and a reference pressure through multiple sensing ports connected to dual averaging plenums. The resultant difference is a differential pressure signal.
Sensing ports are located on both the up and downstream sides of the flow element. The number of ports is proportional to the pipe diameter.
FIGURE 1. Shape Cross-Sections.
DRAMATICALLY REDUCEINSTALLATION ANDOPERATING COSTSThe Annubar primary flow element is inherently easy and inexpensive to install. The small size of the hole required and the minimal welding keep installation costs low.
The primary flow element offers little restriction to flow which, in turn, minimizes pressure drop. The resulting energy and cost savings can positively impact your operating cost.
MOUNTINGCONFIGURATIONS
Fl o-Tap ÿallows installation without system shutdown.
Pak- Lok ÿmounts safely through a weld coupling and packing gland.
Fl anged for high pressure applications.
St reamli ne for large pipes and high velocity.
p
Diamond II+Shape
Streamline Shape
Flow-380
Diamond II+ Annubar®
Diamond
II+Annubar®
Design Principles
DIFFERENTIAL PRESSUREFLOW MEASUREMENT
Flow devices producing a differential pressure signal—called DP devices—have a reputation for accuracy, simplicity, and reliability. The traditional DP devices—orifice plate, venturi tube and flow nozzle, while meeting the above criteria—are expensive to install, limited in application, and most are not energy efficient.
The Diamond II+ sensor is a multiple-tube, rigid structure that provides dual averaging chambers with a diamond-shaped cross section (Figure 2) and bi-directional flow sensing..
FIGURE 2. Diamond II+ Sensor Design.
HOW IT WORKS
The Annubar primary flow element produces a DP signal proportional to the square of the flow rate in accordance with Bernoulli’s theorem. The DP signal has two components: the high pressure (PH) and the low pressure (PL) (Figure 3).
FIGURE 3. PH(avg.) – PL(avg.) = DP (hw).
High Pressure Averaging
The PH is produced by impact or stagnation of the moving fluid on the sensor. The velocity profile results in a corresponding stagnation pressure profile. Multiple sensing ports, located on the front of the sensor, sense the impact pressure profile.
Inside the high pressure chamber, the average velocity pressure is maintained by the proportionality of the sensing port diameters to the chamber cross-sectional area.
Low Pressure AveragingAs the fluid continues around the sensor, it generates a vortex shedding pattern and creates a PL profile. The PL is used as a pressure reference so the velocity can be determined independent of pipe static pressure. The PL is sensed by ports, located downstream and opposite the high pressure ports. Working on the same principle as the PH side, an average PL is maintained in the low pressure chamber. This assures less dependence on the magnitude of flow or Reynolds Number.
40%
60%
Impact Pressure
Pipe StaticPressure
LowPressureSignal
HighPressureSignal
HIGH LOWPH (avg.) PL (avg.)
FLOWVelocityProfile
PH – PL = DP
Blockage andSuction Pressure
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Sensing Ports vs. Pipe Size
Flow laboratory tests have shown that larger pipes are more susceptible to dynamic distortions of the velocity profiles. These dynamic distortions can affect the stability and accuracy of the flow device.
The Diamond II+ design is engineered so that the number of sensing ports is a function of the pipe size (Figure 4).
The additional sensing ports provide a larger sample of the velocity profile, giving a better average of the velocity profile.
TABLE 1. Sensing Ports vs. Pipe Size.
FIGURE 4. Sensing Ports.
Diamond-Shaped Sensors—the Key to Accuracy
The diamond shape establishes a fixed separation point of the fluid from the sensor (Figure 5). The fixed separation point reduces changes in the low, (or reference pressure), that would cause a corresponding loss of accuracy in flow measurement.
Round SensorsRound sensors have a variable separation point of the fluid from the sensor (Figure 5). The separation point varies with fluid type, velocity, surface roughness of the sensor, and turbulence. Sensing ports placed at angles greater than 30° from the front of a round sensor will generate a reference or low pressure signal that is unpredictable—with errors as high as 10%.
FIGURE 5. Fixed vs. Variable Separation Point.
Pipe Size Number of Ports Port Location
2 in. to 5 in. 4 Per ChebyshevCalculus foraveraging6 in. to 14 in. 6
16 in. to 72in.
8 or more
½–2 in. 5 in.24 in.
42 in.
72 in.
10 15/1625/26
35/36
45/46
FixedSeparation Point
Variable Separation Point
Flow-381
Flow-3
Diamond II+ Annubar®
Diamond
II+Annubar®
Sensor size: 10 Line size: 6 Sch 40 Bar # 100000pFluid: WaterPublished K: 0.6392 Date: 10/13/97
Performance
THE DIAMOND II+ SENSOR
Independent flow laboratories have tested and proven the Diamond II+ Annubar primary flow element’s accuracy. Calibration results for water flow at Alden (Alden Research Laboratory, Alden, Massachusetts), NEL (National Engineering Laboratory, Scotland), and gases at CEESI (Colorado Engineering Experimental Station Inc., Nunn, Colorado) show conclusively that the Diamond II+ design improves performance and rangeability compared to traditional DP devices.
Accuracy: ±1% is maintained over a flow turndown of 30:1, depending on the application
Repeatability: ±0.1%
The Diamond II+ SensorExtensive Testing—High Accuracy
Any DP device is only as accurate as its ability to repeat and maintain its flow coefficient (reproducing the same coefficient within a respectable tolerance for different fluids and piping systems). Dieterich Standard, Inc. has completed extensive independent flow laboratory tests in a wide range of pipe sizes and fluids. Typical test results on liquids and highly turbulent gas flows are shown below:
FIGURE 6. Dieterich Standard, Inc. Laboratory.
FIGURE 7. CEESI Laboratory.
82
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Round Sensors
The simplest design for an averaging pitot is a round cylinder. However, as the Reynolds number or flow rate increases, accuracy deteriorates because the separation point of the fluid varies as it passes around the cylinder. This causes a deviation between actual and predicted performance and occurs regardless of the number or location of the sensing ports. Additionally, the level of pipeline turbulence affects the separation point, which makes the deviation impossible to predict.
FIGURE 8. Round Sensors Test Data.
Annubar Primary Flow ElementLong–Term Accuracy
Annubar primary flow element’s flow coefficient remains stable over the long term and is unaffected by wear and dirt or grease buildup.
Annubar Primary Flow Element vs. OrificeAny drift in the flow coefficient (K) results in reduced accuracy. A 10% shift in the K factor results in a 10% error in flow reading.
The orifice long–term accuracy is significantly affected by warping, wear, and dirt or grease buildup.
FIGURE 9. Comparison of Long Term Accuracy: AnnubarPrimary Flow Element vs. Orifice.
Round sensor test results—variable turbulence levels
6" sch. 40 straight pipe –Butterfly valve–20 dia.
Dirt—11%
Damage or Nicks—15%Misalignment—3%
WeldingIcicles orSedimentBuildup—
11%
Independent tests by Florida Gas Transmission Company.
Lubricant—24% Warp—9% Wear—0.050-13%
Flow-383
Flow-3
Diamond II+ Annubar®
Diamond
II+Annubar®
Benefits
ENERGY SAVINGS
The non-constricting design of the Annubar diamond-shaped sensor produces the lowest permanent pressure loss of all primary flow sensors. The non-constricting design also results in significant power savings. An orifice plate typically consumes more than 100 times the energy of an Annubar primary flow element plate.
FIGURE 10. The Annubar Plate vs. the Orifice Plate.
OPERATING COST SAVINGSCompare the orifice and Annubar operating costs. Annubar primary flow element is 100 times more efficient and can offer energy savings of $700 per year per measurement point on liquids, and $30,000 per year savings on gases and steam.
FIGURE 11. Operating Cost Savings.
INSTALLATION COST SAVINGS
Compared to any other primary flow element, Annubar primary flow element has the lowest installation cost.
Annubar vs. Orifice Installation CostsOn an 8 inch (203 mm) pipe, an Annubar primary flow element requires only 4 linear inches (101 mm) of welding. An orifice plate installed in the same pipe requires 50 linear inches (1270 mm) of welding (Figure 13). Annubar primary flow element’s reduced welding requirement saves over ten installation man-hours.
FIGURE 12. Installation Cost Savings.
FIGURE 13. Welding Distances.
Annubar
Orifice
β= 0.6
Actualpressure
loss(inches
ofw.c.)
Act
ualD
.P.p
rodu
ced
(inch
esof
w.c
.)
4 Linear InchesWelding (8 ″pipe)
50 Linear InchesWelding (8 ″pipe)
Annubar primary flow element saves on installation costs—up to 10man-hours less than orifice plate.
84
Rosemount Inc.
Diam
ond
II+An
nuba
r®
ELBOW-MOUNTED ANNUBARPRIMARY FLOW ELEMENT
Although a pipe elbow distorts fully developed flow, it also acts as a flow conditioner, which results in a predictable flow profile immediately downstream of the discharge of the elbow (Figure 14).
When an Annubar primary flow element is installed two pipe diameters downstream of the centerline of the elbow (Figure 15), it will average the velocity profile and provide repeatable, predictable results. The key to accuracy is the prediction of the discharge coefficient, or K-value, in this elbow position.
Dieterich Standard, Inc. has done testing and evaluation to predict this coefficient to within ±3%.
FIGURE 14. Flow Profiles Downstream of an Elbow.
FIGURE 15. Annubar Elbow Installation.
Dieterich Standard, Inc. can also perform the flow calculation for you and provide a computer printout. To do so, specify EO (outside mount) or EI (inside mount), along with the model callout and flow conditions.
FIGURE 16. Annubar Installation Recommendations.
InstallationThe piping requirements for a ±3% accuracy installation will vary based on the piping configuration ahead of the elbow.To be consistent with straight-run requirement charts, see the piping configurations in Figure 17. The upstream straight-run requirements (L1) and the downstream diameters (L2) are in terms of pipe inside diameters (D).
Requirements for Successful Installation• The elbow must have a short radius and be
welded or flanged rather than threaded.• Refer to piping configurations below to verify
minimum diameters available.• Mount the Diamond II+ two pipe inside
diameters from the center of upstream pipe, and in-plane with the elbow (see Figure 16). Either inside or outside radius mounting will work, but the outside radius is preferred, as this allows the higher velocity vectors to be at the support point.
FIGURE 17. Elbow–Mount Annubar PrimaryFlow Element Piping Configurations.
Diamond II+ Annubar primary flow element DCR shown
Non-Swirl Producing Swirl Producing
PipingConfigurations
Min. Req.Values
PipingConfigurations Min. Req. Values
L1 L2 L1 L1 L2
3 2
WithoutConditioner: 4
WithConditioner: N/A
2
4 2
WithoutConditioner: 10
WithConditioner: 5
2
5 2
Valve UseWithoutConditionerFull Open: 3Control: 14
With ConditionerFull Open: 3Control: 10
2
Valve Use Valve Use
Full Open:3
Control:10
2
WithoutConditionerFull Open: 5Control: 16
With ConditionerFull Open: 5Control: 12
2
Valve Use
Full Open:5
Control:12
2
Flow-385
Flow-3
Diamond II+ Annubar®
Diamond
II+Annubar®
Features
DESIGNED-IN ACCURACY
The Diamond Shape is Key
The diamond shape establishes a fixed separation point of the fluid from the sensor (Figure 18). The fixed separation point reduces changes in the low, or reference pressure that would cause a corresponding loss of accuracy in flow measurement. Round sensors have a variable separation point causing an unpredictable reference pressure, and can result in flow measurement errors as high as 10%. See “Design Principles” on page 380.
FIGURE 18. Fixed vs. Variable Separation Point.
Long–Term Accuracy
Dieterich Standard, Inc. has completed extensive independent flow laboratory tests in a wide range of pipe sizes and fluids that consistently demonstrates Annubar primary flow element’s superior ability to repeat and maintain its flow coefficient. A DP device is only as accurate as its ability to do just that. See “Performance” on page 382.
• Alden Research Laboratory
• NEL, National Engineering Laboratory
• CEESI, Colorado Engineering Experimental Station, Inc.
ENERGY COST SAVINGS
The non-constricting design of Annubar primary flow element’s diamond-shaped sensor produces the lowest permanent pressure loss of all primary flow sensors. The low permanent pressure loss results in significant power savings. See “Annubar vs. Orifice Installation Costs” on page 384.
FIGURE 19. Low Permanent Pressure Loss.
INSTALLATION COST SAVINGS
Compared to any other primary flow element, Annubar primary flow element has the lowest installation cost. Savings range from 25% on smaller pipes to 70% on larger pipes. See “Operating Cost Savings” on page 384.
CHOOSE THE MODELADAPTED FOR YOUR APPLICATION
FIGURE 20. Three Model Options.
No System ShutdownAnnubar primary flow element is perfectly suited to retrofit applications because the Flo–Tap models can be hot–tapped without interruption of the flow—that is, without system shutdown. Three Flo–Tap models are available to meet your pressure requirements. See the Specification pages at the end of this section.
FIGURE 21. Flo-Tap: No System Shutdown.
Special MaterialsAnnubar primary flow elements are manufactured from stainless steel or other special materials to meet difficult applications for any industry. Special materials include Kynar® (PVDF), Monel®, Hastelloy®–C, Incoloy® 800 H, and HR 160.
Variable Separation Point
Fixed Separation Point
Round Sensor
Diamond II+ AnnubarPrimary Flow Element
Model Model ModelDHFDHTDMT
150# ANSIEquivalentThreadedAssy
600# ANSI EquivalentThreaded Assy
600# ANSIEquivalentFlangedAssy
Drill ThroughValve
Install
Inserted
86
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Optional Worm Gear Drive
An optional worm gear drive (Figure 22) saves time because of a Single Point Drive system. The Single Point Drive system enables an Annubar primary flow element to be inserted in a 30 inch (762 mm) pipe in only five minutes. The gear can be powered in one of the following three ways:
• Hand crank
• Heavy duty electric drill
• Remote activated drive
FIGURE 22. Worm Gear Drive.
SPECIAL MODELS AND DESIGNS
A special Annubar sensor, MSL, handles high velocity, high temperature, and high pressure flows (up to 1015 °F/546 °C @ 2600 psig/17926 kPa). These conditions are typical in a Main Steam Line from a major power plant.
Annubar primary flow element systems have been designed for Continuous Emission Rate Monitoring (CERM) applications on large diameter stacks. These systems meet U.S. EPA 40CFR75 requirements such as purging and automatic daily calibration checks. DSF models are available for complete spanning of the diameter of the stack. For stacks exceeding 20 foot (6 meter) diameters, array models extending part way into the stack are available.
Pak-Lok Mounting HardwareSafety is the key to the Dieterich Standard, Inc. patented Pak–Lok mounting (Figure 23). Pak–Lok mounting seals and retains the sensor firmly against the inside opposite wall simply and without high torque requirements. Unlike a ferrule-mounted sensor, a Pak-Lok-mounted Annubar primary flow element can be installed and removed easily.
FIGURE 23. Pak-Lok Mounting.
Elbow-Mounted AnnubarPrimary Flow Element
Insufficient straight run is common in today's piping, but Annubar primary flow element averages the flow profile so it can provide accurate, repeatable flow measurement when installed two diameters downstream of a 90° elbow.
Bi–Directional FlowsThe symmetrical design, along with the controlled separation point provided by the exclusive diamond-shaped sensor, means that a single Annubar primary flow element is all that is required for bi-directional flow measurement.
Integral Manifold HeadThe integral manifold head provides a three valve manifold built-in to the Annubar sensor (Figure 24). Mount a DP transmitter to the Annubar sensor and simplify installation.
FIGURE 24. Integral Manifold Head.
Integral Valve HeadThe integral valve head features a compact design that requires fewer tubing connections (Figure 25). This means a more reliable, leak-free installation. Maintenance is also easier because seats can be replaced without disassembling tubing. Integral valve heads are not recommended on Flo–Taps above 400 °F (204 °C) or for steam applications.
FIGURE 25. Integral Valve Head.
Integral Temperature SensorSelected Annubar primary flow element models are available with a “built-in” temperature sensor (Figure 26). This feature eliminates an additional pipe connection and thermowell.
FIGURE 26. Integral Temperature Sensor.
Pak–Lok Nut
Packing Follower
Packing RingsWeldedLock Ring
Welded Fitting
O–Ring Groove
½ in.—14 NPT
Flow-387
Flow-3
Diamond II+ Annubar®
Diamond
II+Annubar®
Installation
ORIENTATION
Note: Other orientations are possible with additional considerations.
Horizontal Pipes
FIGURE 27. Liquids and Steam.
FIGURE 28. Gases.
Vertical Pipes
FIGURE 29. Liquids and Gases.
FIGURE 30. Steam.
LOCATION
Recommended Approachand Depart Values
Selecting correct mounting locations for the Annubar primary flow element in the pipeline is important because disturbance in flow produced by pipe layout may affect the accuracy of measurement.
Straight Run Requirements
Use of recommended straight pipe lengths of uniform diameter upstream and downstream ensures that flow measurement will be made in flow with fully developed characteristics.
The following chart describes the minimum number of pipe diameters upstream and downstream of the Annubar. Longer lengths are always preferred (if available) for accurate flow measurement.
Note: Straight runs listed below are for water. Multiply times 1.5 for gases.
FIGURE 31. Installation Hole Sizes.
50° 50°
80° (Recommended zone)
30° 30°
120°(Recommended
zone)
Flow
360°
Upstream Dimensions
MinimumDiameters ofStraight Pipe
Without Vanes With Vanes DownstreamDimension
B
InPlane
A
Outof
Plane A
A’ C C’
8 1048 4 4
11 1648 4 4
23 2848 4 4
12 1248 4 4
18 1848 4 4
30 3048 4 4
Installationhole sizes 15 16 25 26 35 36 45 4
88
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Sizing and How To Order
1. CHOOSE A MOUNTING METHOD
Line sizes 2 inches and larger
DCR
FIGURE 32. Regular ThreadedPak–Lok Assembly.
Mounting Method: Threaded Pak–Lok.Pipe Sizes: 2 in. to 72 in. (50 mm to 1800 mm).
DFF
FIGURE 33. Flanged.
Mounting Method: Flanged.Pipe Sizes: 2 in. to 72 in. (50 mm to 1800 mm).
DPF
FIGURE 34. Flanged Pak–Lok.
Mounting Method: Flanged Pak–Lok.Pipe Sizes: 2 in. to 72 in. (50 mm to 1800 mm).
Line sizes ½ in. to 2 in.
DNT
FIGURE 35. Threaded In–Line.
Mounting Method: Male threaded.Pipe Sizes: 0.5 in. to 2 in. (25 mm to 50 mm).
DNF
FIGURE 36. Flanged In–Line.
Mounting Method: Flanged and gasket.Pipe Sizes: 0.5 in. to 2 in. (25 mm to 50 mm).
DNW
FIGURE 37. Welded In–Line.
Mounting Method: Welded in-line.Welded Pipe Sizes: 0.5 in. to 2 in. (25 mm to 50 mm).
Flo-Tap Model 8
DMT
FIGURE 38. Medium PressureThreaded Flo–Tap.
Mounting Method: Threaded Flo–Tap for pressure equivalent to ANSI Class 150 Flanges.Pipe Sizes: 2 in. to 72 in. (50 mm to 1800 mm).
DHT
FIGURE 39. High PressureThreaded Flo–Tap.
Mounting Method: Threaded Flo–Tap for pressure equivalent to ANSI Class 600 Flanges.Pipe Sizes: 2 in. to 72 in. (50 mm to 1800 mm).
DHF
FIGURE 40. High PressureFlanged Flo–Tap.
Mounting Method: Flanged Flo–Tap for pressure equivalent to ANSI Class 600 Flanges.Pipe Sizes: 2 in. to 72 in. (50 mm to 1800 mm).
Flow-389
Diamond II+ Annubar®
Flow-3
Diamond
II+Annubar®
2. CHOOSE A SENSOR SIZE
There are four Annubar primary flow element sensor sizes to choose from. The following table is a guideline to help select the correct the sensor.
TABLE 2. Sensor Size.
Using the smallest applicable sensor for a given line size is recommended. Use larger sensors where structural integrity requires it. A complete calculation, including structural analysis, is completed for every application using the Instrument Toolkit and/or Merlin software packages. Sensor 25/26 is preferred to sensor 15/16 in the 4-inch and 5-inch lines because the recommended product including integral transmitter mounting and integral RTD are unavailable in sensor 15/16.
Calculate Approximate Differential Pressure (hw)
Use fluid parameters at maximum flow rate. To calculate the differential pressure, use the equations below, the Dieterich Standard, Inc. Annubar primary flow element sizing program, or the Annubar Primary Flow Element Handbook.
Sensor Size Line Sizes
15/16 2 in. to 5 in.
25/26 4 in. to 42 in.
35/36 8 in. to 72 in.
45/46 10 in. to 72 in.
Equations to Calculate Differential Pressure
Liquid, gas & steam (mass rate of flow)
Liquid (volume rate of flow)
Gas (standard volumetric flow)
Gas (actual volume rate of flow)
hw1ρf-----
lbm hr⁄
358.94KD2-------------------------------
2=
ÿ ÿ= differential pressure, inches of water @ 68°F
K = flow coefficient
D= internal pipe diameter, inches
lbm / hr = pounds mass per hour
GPM = U.S. gallons per minute
ACFH = Actual cubic feet per hour
SCFH = Standard cubic feet per hour (@ 14.73 psia and 60° F)
ρf = flowing density, lbm / ft3 for gas:
.076487 lbm / ft3= Air density at 14.73 psia and 60°F.
Gf = Specific gravity of liquid
G = Specific gravity of gas (molecular weight of air = 28.9644)
Tf = Temperature of flowing gas in degrees Rankin (°R = °F + 460)
ρf = Flowing pressure, psia
K = 0.6 for approximate sizing
Pf14.73---------- 520
Tf------- 0.076487G××
hw Gf( ) GPM( )
5.666KD2( )--------------------------------
2=
hwTfG
Pf---------- SCFH
7 711KD2,-----------------------------
2=
hw ρf( ) ACFH
358.94KD2-------------------------------
2=
90
Rosemount Inc.
Diam
ond
II+An
nuba
r®
3. VERIFY MODEL AND SENSOR SIZE
Compare maximum allowable flow to your maximum flow rates.
HW= maximum differential pressure in inches of water column Structural limits apply to 200°F and below.
SCFM = maximum air flow in standard cubic feet per minute For applications requiring higher values, consult factory
GPM = maximum water flow in gallons per minute 1.2 in. to 24 in. Sch 40
At standard conditions: air: 60°F at 14.73 psia 30 in. to 42 in. Sch Std.
water: 60°F, specific gravity 1.0, viscosity 1.12 centipoise 48 in. to 72 in. Actual Id
† During insertion and retraction of Flo–Tap sensors, flow rate must be reduced to give lower DP values equal to the DP limits of DFF models of the same sensor size.
Nom.Pipe
Size (ininches)
Sensor 10
DNT DNF DNW
SCFM HW GPM SCFM HW GPM SCFM HW GPM
.5 180.52 1500 50.943 180.52 1500 50.943 180.52 1500 50.943
.75 307.79 1500 89.404 307.79 1500 89.404 307.79 1500 89.404
1 498.82 1500 144.9 498.82 1500 144.9 498.82 1500 144.9
1.25 765.68 1180 222.41 765.68 1180 222.41 765.68 1180 222.41
1.5 902.04 884 262.02 902.04 884 262.02 902.04 884 262.02
2 1174.9 552 341.28 1174.9 552 341.28 1174.9 552 341.28
Sensor 15 Sensor 16
DCR DFF DHF† DPF DMT†/DHT† DCR DFF
SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM
2 1236.1 611 359.05 502.91 84.3 133.37 1555 967 451.7 1132.3 494 322.85 1324.9 702 384.87 1236.1 611 359.05 1322 699 384.04
2.5 1531.9 451 440.14 639.74 66.9 169.52 1886.4 699 547.95 1396 360 393.23 1623.9 518 471.7 1531.9 451 440.14 1641 529 476.68
3 2010.5 314 567.07 859.71 50.5 227.41 2408.7 478 699.65 1810.1 246 501.92 2127.9 360 607.18 2010.5 314 567.07 2175.3 380 623.82
3.5 2408.7 246 671.26 1046.1 41.7 276.37 2852.6 369 822.13 2158.9 192 593.03 2554 282 718.7 2408.7 246 671.26 2639.5 305 747.44
4 2816 199 777.38 1237.1 35.1 326.46 3331.3 294 944.89 2516 155 686.08 2989.7 228 832.1 2816 199 777.38 3126.9 253 876.53
5 3723.8 137 1013.6 1663.7 25.6 438.17 4364.9 195 1209.3 3306.2 106 891.62 3950.9 156 1081.7 3723.8 137 1013.6 4213.3 180 1161.9
Sensor 25 Sensor 26
DCR DFF DHF† DPF DMT†/DHT† DCR DFF
SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM
4 6263.45 1090 1819.4 2827.2 189 757.59 7347.5 1500 2134.3 5621.4 878 1632.9 6892.6 1320 2002.1 6263.45 1090 1819.4 7047.5 1380 2047.1
5 8148.5 747 2366.9 3798.1 138 1017.3 10066 1140 2924 7290.6 598 2117.8 8929.2 897 2593.7 8148.5 747 2366.9 9366.4 987 2720.7
6 10088 549 2930.2 4839.5 107 1293.6 12299 816 3572.4 9117 439 2620.3 11019 655 3200.7 10088 549 2930.2 11783 749 3422.6
8 14100 346 4028.2 6867.4 71.2 1827.3 16486 489 4788.8 12849 277 3604.2 15029 406 4363.5 14100 346 4029.2 16570 494 4813.2
10 18737 235 5232.7 9125.3 50.2 2418.5 21270 318 6087.1 17067 190 4750.1 19910 271 5619.2 18737 235 5232.7 22053 348 6367.7
12 23218 174 6391.4 11299 38 2986.8 26142 228 7316.3 21180 142 5773.9 24588 198 6815 23218 174 6391.4 27773 263 7857.8
14 25971 147 7099.9 12665 32.6 3343.5 29131 190 8071.7 23752 121 6441.4 27511 167 7567.4 25971 147 7099.9 31411 226 8803.3
16 30390 116 8238.9 14829 26.1 3908.1 33874 147 9274.7 27865 96.3 7506.8 32028 130 8721.9 30390 116 8238.9 37265 182 10320
18 34880 94.2 9397.7 17017 21.4 4479.2 38584 117 10473 32060 78.8 8595.3 36692 105 9921.8 34880 94.2 9397.7 43086 149 11819
20 39558 77.7 10608 19311 17.8 5077.3 43384 94.5 11699 36469 65.5 9139.6 41459 85.8 11147 39558 77.7 10608 49210 124 13401
24 48768 55.7 12990 23901 13 6275.5 52897 66 14140 45250 47.7 12021 50822 60.7 13560 48768 55.7 12990 61463 90.6 16567
30 65577 35.6 17355 32211 8.43 8445.5 70325 41.1 18648 61287 31 16195 67950 38.3 18002 65577 35.6 17355 83933 59.3 22399
36 80406 25.2 21207 39598 6.03 1037.4 85555 28.6 22592 75714 22.3 19949 83023 26.9 21911 80406 25.2 21207 103900 42.6 27573
42 95305 18.8 25083 47023 4.53 12313 100650 21 26510 90424 16.9 23782 98014 19.9 25807 95305 18.8 25083 123750 32 32725
Flow-391
Diamond II+ Annubar®
Flow-3
Diamond
II+Annubar®
HW = hw = maximum differential pressure in inches of water column Structural limits apply to 200°F and below.
SCFM = maximum air flow in standard cubic feet per minute For applications requiring higher values, consult factory
GPM = maximum water flow in gallons per minute 1.2 in. to 24 in. Sch 40
At standard conditions: air: 60°F at 14.73 psia 30 in. to 42 in. Sch Std.
water: 60°F, specific gravity 1.0, viscosity 1.12 centipoise 48 in. to 72 in. Actual Id
† During insertion and retraction of Flo–Tap sensors, flow rate must be reduced to give lower DP values equal to the DP limits of DFF models of the same sensor size.
Nom.Pipe
Size (ininches)
Sensor 35 Sensor 36
DCR DFF DHF† DPF DMT†/DHT† DCR DFF
SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM
8 20661 768 6001.4 9950.2 153 2678.7 24501 1080 7116.8 18338 605 5326.6 22166 884 6438.7 20661 768 6001.4 24387 1070 7083.8
10 26823 521 7791.3 13239 108 3547.4 31224 706 9069.8 24088 414 6945.3 28592 592 8305.3 26823 521 7791.3 32204 751 9351.3
12 32883 385 9507.2 16469 82.3 4395.6 37485 505 10088 30074 309 8519.3 34710 433 10082 32833 385 9507.2 39824 570 11568
14 37058 327 10589 18488 70.7 4923.8 41364 421 12015 33895 264 9514.6 38729 365 11188 37058 327 10589 44625 490 12962
16 43668 258 12287 21690 56.7 5760.1 48040 325 13791 39957 210 11085 45595 286 12937 43668 258 12287 52273 394 15184
18 50338 209 13998 24947 46.6 6609.8 55095 258 15553 46180 172 12699 52469 230 14685 50338 209 13998 60481 324 17429
20 57299 172 15783 28344 38.8 7496.1 62559 210 17439 52719 143 14391 59608 188 16501 57299 172 15783 69596 270 19774
24 71017 123 19303 36548 28.3 9259.1 76801 146 21031 65702 104 17750 73609 133 20072 71017 123 19303 87930 198 24491
30 96282 78.9 25837 47441 18.4 12477 103040 91.1 27763 89649 67.9 23969 999349 84.3 26707 96282 78.9 25837 121480 130 33165
36 118650 56 31613 58452 13.2 15348 125830 63.3 33611 11250 49 29572 121960 59.3 32531 118650 56 31613 151120 93.2 40783
42 1411020 41.8 37402 69564 9.95 18248 148640 46.6 39491 133070 37.1 35237 144570 44 35374 141020 41.8 37402 181070 70.3 48505
48 163400 32.4 43205 80662 7.76 21144 171330 35.7 45353 155040 29.1 40946 167050 33.9 44194 163400 32.4 43205 211020 54.9 56240
60 208140 21.1 54825 102920 5.1 26954 216230 22.8 56991 199180 19.3 52434 211980 21.9 55855 208140 21.1 54825 270800 36.1 71712
72 253470 14.9 66623 125280 3.61 32793 261750 15.9 68822 243170 13.7 63883 256820 15.3 67511 253470 14.9 66623 330970 25.6 87327
Sensor 45 Sensor 46
DCR DFF DHF† DPF DMT†/DHT† DCR DFF
SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM SCFM HW GPM
10 41878 1270 12165 20133 256 5461.5 45513 1500 13220 37086 996 10713 N/A N/A N/A 41878 1270 12165 45513 1500 13220
12 51142 940 14855 24994 195 6766.1 59210 1260 17199 45499 744 13216 N/A N/A N/A 51142 940 14855 61288 1350 17803
14 56913 797 16532 28092 168 7590.1 65325 1050 18975 50681 635 14756 N/A N/A N/A 56913 797 16532 68661 1160 19944
16 66100 630 19200 33012 135 8888.1 74858 808 21744 59297 507 17224 N/A N/A N/A 66100 630 19200 80698 939 23441
18 75353 511 21888 38019 111 10201 84461 642 24534 68260 416 19749 N/A N/A N/A 75353 511 21888 92738 774 26938
20 85108 422 24722 43418 93.2 11618 94565 521 27469 78331 346 22385 N/A N/A N/A 85108 422 24722 105460 648 30634
24 106480 303 30297 53975 68.2 14374 114620 364 33207 98553 252 27630 N/A N/A N/A 106480 303 30291 130590 475 37933
30 146170 194 40515 73415 44.7 19448 156190 226 43729 136026 165 37364 N/A N/A N/A 146170 194 40515 178800 313 51462
36 181760 138 49627 90648 32.1 23938 192700 157 52933 169830 119 46084 N/A N/A N/A 181760 138 49627 226020 226 63508
42 217210 103 58712 108240 24.3 28517 229510 116 62307 204130 90.2 54943 N/A N/A N/A 217210 103 58712 273660 171 75649
48 251110 78.8 67379 125770 19 33086 265390 88.6 71446 238660 70.8 63867 N/A N/A N/A 251110 78.8 67379 321370 134 87865
60 321930 51.5 85653 160730 12.5 42190 337470 56.8 89952 308340 4701 81912 N/A N/A N/A 321930 51.5 85653 416410 88.4 112220
72 392880 36.3 103990 195900 8.86 51374 408770 39.4 108340 378250 33.6 100050 N/A N/A N/A 392880 36.3 103990 511830 62.8 136780
92
Rosemount Inc.
Diam
ond
II+An
nuba
r®
4. CHOOSE THE MODEL OPTIONS
Model Numbers Description Page Numbers
Standard Models Line Sizes 2 Inches and Larger
DCR+15/16S Diamond II+ Annubar Primary Flow Element—Regular (Pak-Lok, Threaded), SST page 395
DCR+25/26S Diamond II+ Annubar Primary Flow Element—Regular (Pak-Lok, Threaded), SST page 397
DCR+35/36S Diamond II+ Annubar Primary Flow Element—Regular (Pak-Lok, Threaded), SST page 400
DCR+45/46S Diamond II+ Annubar Primary Flow Element—Regular (Pak-Lok, Threaded), SST page 403
DFF+15/16S Diamond II+ Annubar Primary Flow Element—Flanged, SST page 409
DFF+25/26S Diamond II+ Annubar Primary Flow Element—Flanged, SST page 411
DFF+25/26H Diamond II+ Annubar Primary Flow Element—Flanged, Hastelloy–C page 414
DFF+25/26M Diamond II+ Annubar Primary Flow Element—Flanged, Monel page 417
DFF+35/36S Diamond II+ Annubar Primary Flow Element—Flanged, SST page 420
DFF+45/46S Diamond II+ Annubar Primary Flow Element—Flanged, SST page 423
DFF+45/46H Diamond II+ Annubar Primary Flow Element—Flanged, Hastelloy–C page 426
DFF+45/46M Diamond II+ Annubar Primary Flow Element—Flanged, Monel page 428
DPF+15/16S Diamond II+ Annubar Primary Flow Element—Pak-Lok Flanged, SST page 434
DPF+25/26S Diamond II+ Annubar Primary Flow Element—Pak-Lok Flanged, SST page 436
DPF+35/36S Diamond II+ Annubar Primary Flow Element—Pak-Lok Flanged, SST page 438
DPF+45/46S Diamond II+ Annubar Primary Flow Element—Pak-Lok Flanged, SST page 440
In–line sizes: ½ in. to 2 in.
DNT+10S Diamond II+ Annubar Primary Flow Element—In-Line Threaded, SST page 446
DNF+10S Diamond II+ Annubar Primary Flow Element—In-Line Flanged, SST page 447
DNF+10H Diamond II+ Annubar Primary Flow Element—n-Line Flanged, Hastelloy–C page 449
DNF+10M Diamond II+ Annubar Primary Flow Element—In-Line Flanged, Monel page 450
DNW+10S Diamond II+ Annubar Primary Flow Element—In-Line Butt Weld, SST page451
Flo–Tap Models
DMT+15S Diamond II+ Annubar Primary Flow Element—Threaded Flo-Tap, SST page 456
DMT+25S Diamond II+ Annubar Primary Flow Element—Threaded Flo-Tap, SST page 458
DMT+35S Diamond II+ Annubar Primary Flow Element—Threaded Flo-Tap, SST page 461
DHT+15S Diamond II+ Annubar Primary Flow Element—Threaded Flo-Tap, SST page 469
DHT+25S Diamond II+ Annubar Primary Flow Element—Threaded Flo-Tap, SST page 471
DHT+35S Diamond II+ Annubar Primary Flow Element—Threaded Flo-Tap, SST page 474
DHF+15S Diamond II+ Annubar Primary Flow Element—Flanged Flo-Tap, SST page 482
DHF+25S Diamond II+ Annubar Primary Flow Element—Flanged Flo-Tap, SST page 485
DHF+25H Diamond II+ Annubar Primary Flow Element—Flanged Flo-Tap, Hastelloy–C page 488
DHF+25M Diamond II+ Annubar Primary Flow Element—Flanged Flo-Tap, Monel page 491
DHF+35S Diamond II+ Annubar Primary Flow Element—Flanged Flo-Tap, SST page 494
DHF+45S Diamond II+ Annubar Primary Flow Element—Flanged Flo-Tap, SST page 497
DHF+45H Diamond II+ Annubar Primary Flow Element—Flanged Flo-Tap, Hastelloy–C page 500
DHF+45M Diamond II+ Annubar Primary Flow Element—Flanged Flo-Tap, Monel page 503
Flow-393
Flow-3
Diamond II+ Annubar®
Diamond
II+Annubar®
5. VERIFY PROCESS AND PIPE INFORMATION
Configuration Information
When ordering an Annubar primary flow element, it is important to include all of the flowing conditions and pipe information for your application. This will ensure that you receive the correct product for your application. Please see the Annubar primary flow element Configuration Data Sheet 00806–0100–4760.
Dimension CodesCertain dimensions are critical to fabrication of the primary flow element assembly. The following codes can be specified in the model callout “string” and Dieterich Standard, Inc. will build the primary flow element assembly to suit. If no dimension is specified, cataloged components will default to standard dimensions.
ODH
ODH is the outside diameter of the pipe to the top of the Annubar primary flow element head (Figure 41). If this dimension is specified for a flanged, Flo–Tap, or Regular model, the neck of the primary flow element just below standard dimension can be considered a minimum. This dimension does not apply to in–line sensors or to model 45s.
FIGURE 41. ODH.
ODF
ODF is the outside diameter of the pipe to the face of the mounting flange (Figure 42). This dimension applies only to DFF, DHF, DSF, NFF, SPF, SFF, and SSF models. If Dieterich Standard, Inc. is not supplying the mounting hardware, this dimension must be specified. If Dieterich Standard, Inc. is providing the mounting flange assembly, note the following:
• The standard ODF is a minimum.
• The extensions must be at least 2 inches longer than the minimum ODF.
FIGURE 42. ODF.
ODV
ODV is the outside diameter of the pipe to the top of the isolation valve (Figure 43). ODV applies to Flo–Tap models only, and only when the customer supplies some or all of the mounting hardware.
FIGURE 43. ODV.
NL
NL is the nipple length for DNW, DNF, and DNT-10 in-line models (Figure 44). Additional length can be specified to fit specific piping configurations. The extra length will be applied upstream of the sensor unless otherwise specified.
FIGURE 44. NL.
CMH
CMH is the customer mount height distance from the outside of the pipe to the top of the appropriately sized NPT threaded female mounting coupling (Figure 45). Supply these values for Regular and Flo–Tap models that are being installed in a customer’s mounting or saddle.
FIGURE 45. CMH.
ODH
ODF
ODV
CMH
94
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Ordering Information—Model DCRMODEL DCR+15S/16S
Model Product Description
DCR+15SDCR+16S
Diamond II + Annubar® Primary Flow Element - Regular (Threaded, Pak-Lok)Diamond II + Annubar® Primary Flow Element - Regular (Threaded, Pak-Lok) with Opposite Side Support, SST
Code Line Size
020025030035040050
2 in. (50 mm)21/2 in. (63.5 mm)3 in. (80 mm)31/2 in. (89 mm)4 in. (100 mm)5 in. (125 mm)
Code Head Style
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0SA2C0CP2C0SP2C0
Needle Valves - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Steam, 1/2—14 NPT, CS
CP2S0SA2S0CP2SSSP2S0SP2SSCA2S0CA2SS
Needle Valves - SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SST
CB2C0SB2C0CC2C0SC2C0SV2C0
Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0
Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
SV2S0SV2SS
Gate Valves - SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee,1/2 in. Socket Weld Ports, SST
Code Mounting Hardware
MP2C0MP2S0MR2C0MR2S0
Pak-Lok, with Contoured Weld Fitting, 1/2—14 NPT, CSPak-Lok, with Contoured Weld Fitting, 1/2—14 NPT, SSTPak-Lok, No Contoured Weld Fitting, 1/2—14 NPT, CSPak-Lok, No Contoured Weld Fitting, 1/2—14 NPT, SST
Flow-395
Flow-3
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Opposite Side Support (Required for Model 16S only)
MS2C0MS2CWMS2S0MS2SW
Contoured Weld Fitting and Plug, 1—11.5 NPT, CSContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 1—11.5 NPT, SSTContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, SST
Code Optional Auxiliary Mounting (Mounting alternatives for use when Contoured Weld Fitting is Not Specified in Mounting Hardware)
MT2CMT2SME2CME2AME2KME2PME2SNB20NC20ND20NE20NF20
Contoured Weld Fitting, 1/2—14 NPT, CSContoured Weld Fitting, 1/2—14 NPT, SSTWeld Coupling, 1/2—14 NPT, CSWeld Coupling, 1/2—14 NPT, AluminumWeld Coupling, 1/2—14 NPT, CopperWeld Coupling, 1/2—14 NPT, PVCWeld Coupling, 1/2—14 NPT, SSTSaddle, Double Strap, 2.35 to 2.56 O.D., 1/2—14 NPT, IronSaddle, Double Strap, 2.41 to 2.91 O.D., 1/2—14 NPT, IronSaddle, Double Strap, 2.97 to 3.54 O.D., 1/2—14 NPT, IronSaddle, Double Strap, 4.14 to 4.80 O.D., 1/2—14 NPT, IronSaddle, Double Strap, 5.94 to 6.70 O.D., 1/2—14 NPT, Iron
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXR
Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element
Code Optional Calibration
MZ
Lab Flow Calibration (Average K) (<10 in.)Special Calibration
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DCR+15S 020 HA2S0 CA2C0 MP2C0
MODEL DCR+15S/16S
96
Rosemount Inc.
Diam
ond
II+An
nuba
r®
MODEL DCR+25S/26SModel Product Description
DCR+25SDCR+26S
Diamond II + Annubar® Primary Flow Element - Regular (Threaded, Pak-Lok)Diamond II + Annubar® Primary Flow Element - Regular (Threaded, Pak-Lok) with Opposite Side Support, SST
Code Line Size
040050060080100120140160180200240300360420
4 in. (100 mm)5 in. (125 mm)6 in. (150mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)
Code Head Style
HADS0HADSBHADSNHAPS0HAMS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST
HATSNHATSBHATSDHATS0
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTIntegral, with 3-Valve Manifold, RTD, Horizontal Line, SST
HVDS0HVDSBHVDSNHVPS0HVMS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST
HVTSBHVTSDHVTSNHVTS0
Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, with 3-Valve Manifold, RTD, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0SA2C0CP2C0SP2C0
Needle Valves - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
Flow-397
Flow-3
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Instrument Connections (Continued)
CP2S0SA2S0CP2SSSP2S0SP2SSCA2S0CA2SS
Needle Valves - SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SST
CB2C0SB2C0CC2C0SC2C0SV2C0
Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS
Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
Code Mounting Hardware
MR4C0MR4S0MP4C0MP4S0
Pak-Lok, No Contoured Weld Fitting, 1—11.5 NPT, CSPak-Lok, No Contoured Weld Fitting, 1—11.5 NPT, SSTPak-Lok, with Contoured Weld Fitting, 1—11.5 NPT, CSPak-Lok, with Contoured Weld Fitting, 1—11.5 NPT, SST
Code Opposite Side Support (Required for Model 26S only)
MS4C0MS4CWMS4S0MS4SW
Contoured Weld Fitting and Plug, 1—11.5 NPT, CSContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 1—11.5 NPT, SSTContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, SST
Code Optional Auxiliary Mounting (Mounting alternatives for use when Contoured Weld Fitting is Not Specified in Mounting Hardware)
MT4CMT4SME4CME4AME4KME4PME4SNE40NF40NG40NH40NJ40
Contoured Weld Fitting, 1—11.5 NPT, CSContoured Weld Fitting, 1—11.5 NPT, SSTWeld Coupling, 1—11.5 NPT, CSWeld Coupling, 1—11.5 NPT, AluminumWeld Coupling, 1—11.5 NPT, CopperWeld Coupling, 1—11.5 NPT, PVCWeld Coupling, 1—11.5 NPT, SSTSaddle, Double Strap, 3.74 to 4.55 O.D., 1—11.5 NPT, IronSaddle, Double Strap, 5.94 to 6.7 O.D., 1—11.5 NPT, IronSaddle, Double Strap, 8.54 to 10.1 O.D., 1—11.5 NPT, IronSaddle, Double Strap,10.64 to 12.12 O.D., 1—11.5 NPT, IronSaddle, Double Strap, 12.6 to 14.3 O.D., 1—11.5 NPT, Iron
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRATRPTXATXPTRRTXR
Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element
MODEL DCR+25S/26S
98
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DCR+25S 040 HAMS0 C0000 MP4C0
MODEL DCR+25S/26S
Flow-399
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
MODEL DCR+35S/36SModel Product Description
DCR+35SDCR+36S
Diamond II + Annubar® Primary Flow Element - Regular (Threaded, Pak-Lok)Diamond II + Annubar® Primary Flow Element - Regular (Threaded, Pak-Lok) with Opposite Side Support, SST
Code Line Size
080100120140160180200240300360420480600720
8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HADS0HADSBHADSNHAPS0HAMS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST
HATSNHATSBHATSDHATS0
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTIntegral, with 3-Valve Manifold, RTD, Horizontal Line, SST
HVDS0HVDSBHVDSNHVPS0HVMS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST
HVTSBHVTSDHVTSNHVTS0
Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, with 3-Valve Manifold, RTD, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0SA2C0CP2C0SP2C0
Needle Valves - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
00
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Instrument Connections (Continued)
CP2S0SA2S0CP2SSSP2S0SP2SSCA2S0CA2SS
Needle Valves - SSTNeedle Valve, Nipple, 1/2—14 NPT,Needle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SST
CB2C0SB2C0CC2C0SC2C0SV2C0
Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS
Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
Code Mounting Hardware
MP6C0MP6S0MR6C0MR6S0
Pak-Lok, with Contoured Weld Fitting, 11/2—11.5 NPT, CSPak-Lok, with Contoured Weld Fitting, 11/2—11.5 NPT, SSTPak-Lok, No Contoured Weld Fitting, 11/2—11.5 NPT, CSPak-Lok, No Contoured Weld Fitting, 11/2—11.5 NPT, SST
Code Opposite Side Support (Required for Model 36S only)
MS6C0MS6CWMS6S0MS6SW
Contoured Weld Fitting and Plug, 11/2—11.5 NPT, CSContoured Weld Fitting and Plug, 11/2 in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 11/2—11.5 NPT, SSTContoured Weld Fitting and Plug, 11/2 in. Socket Weld Ports, SST
Code Optional Auxiliary Mounting (Mounting alternatives for use when Contoured Weld Fitting is Not Specified in Mounting Hardware)
MT6CMT6S
Contoured Weld Fitting, 11/2—11.5 NPT, CSContoured Weld Fitting, 11/2—11.5 NPT, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRATRPTXATXPTRRTXR
Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
MODEL DCR+35S/36S
Flow-401
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Optional Quality Assurance
QA1QA2Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramCertified ProgramANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DCR+35S 120 HAMS0 C0000 MP6C0
MODEL DCR+35S/36S
02
Rosemount Inc.
Diam
ond
II+An
nuba
r®
MODEL DCR+45S/46SModel Product Description
DCR+45SDCR+46S
Diamond II + Annubar® Primary Flow Element - Regular (Threaded, Pak-Lok)Diamond II + Annubar® Primary Flow Element - Regular (Threaded, Pak-Lok) with Opposite Side Support, SST
Code Line Size
100120140160180200240300360420480600720
10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HADS0HADSBHADSNHAPS0HAMS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST
HATSNHATSBHATSDHATS0
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTIntegral, with 3-Valve Manifold, RTD, Horizontal Line, SST
HVDS0HVDSBHVDSNHVPS0HVMS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST
HVTSBHVTSDHVTSNHVTS0
Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, with 3-Valve Manifold, RTD, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0
Needle Valves - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
CP2S0CP2SSSP2S0SP2SS
Needle Valves - SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple,1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
Flow-403
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Instrument Connections (Continued)
CC2C0SC2C0SV2C0
Gate Valves - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2SSCC2S0CC2SSSC2S0SV2S0SV2SS
Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow,1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee,1/2 in. Socket Weld Ports, SST
Code Mounting Hardware
MPDC0MPDS0
Pak-Lok, with Contoured Weld Fitting, 3—8 NPT, CSPak-Lok, with Contoured Weld Fitting, 3—8 NPT, SST
Code Opposite Side Support (Required for Model 46S only)
MSDCWMSDSW
Contoured Weld Fitting and Cap, 3 in., Butt Weld, CSContoured Weld Fitting and Cap, 3 in., Butt Weld, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRATRPTXATXPTRRTXR
Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DCR+45S 200 HAMS0 C0000 MPDC0
MODEL DCR+45S/46S
04
Diam
ond
II+An
nuba
r®
Rosemount Inc.
Flow-405
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
06
Diam
ond
II+An
nuba
r®
Rosemount Inc.
Flow-407
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
08
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Ordering Information—Model DFFMODEL DFF+15S/16S
Model Product Description
DFF+15SDFF+16S
Diamond II+ Annubar® Primary Flow Element - Flanged, SSTDiamond II+ Annubar® Primary Flow Element - Flanged with Opposite Side Support, SST
Code Line Size
020025030035040050
2 in. (50 mm)2½ in. (63.5 mm)3 in. (80 mm)3½ in. (89 mm)4 in. (100 mm)5 in. (125 mm)
Code Head Style
HAMS0HADS0HADSBHADSNHAPS0
Direct Mount - HorizontalIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SST
HVPS0HVMS0HVDS0HVDSBHVDSN
Direct Mount - VerticalDirect Mount, No Manifold, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SSHAHS0HAHSS
Remote Mount - HorizontalAxial, Horizontal Line, ½—14 NPT, SSTAxial, Horizontal Line, ½ in. Socket Weld Ports, SSTParallel, Horizontal Line, ½—14 NPT, SSTParallel, Horizontal Line, ½ in. Socket Weld Ports, SSTAxial, HP, Horizontal Line, ½—14 NPT, SSTAxial, HP, Horizontal Line, ½ in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SSHVHS0HVHSS
Remote Mount - VerticalParallel, Vertical Line, ½ in. Socket Weld Ports, SSTParallel, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½ in. Socket Weld Ports, SSTAxial, HP, Vertical Line, ½—14 NPT, SSTAxial, HP, Vertical Line, ½ in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valves - CSNeedle Valve, Elbow, ½—14 NPT, CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Elbow and Tee, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS
CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS
Needle Valves - SSTNeedle Valve, Elbow, ½—14 NPT, SSTNeedle Valve, Elbow, ½ in. Socket Weld Ports, SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Nipple, ½ in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½ in. Socket Weld Ports, SST
CB2C0CC2C0SB2C0SC2C0SV2C0
Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS
Flow-409
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
10
Code Instrument Connections (Continued)
CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS
Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, ½ in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, ½ in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½ in. Socket Weld Ports, SST
Code Sensor Flange
FNMS0FLMS0FJMS0FF4S0FE4S0FC4S0FB4S0FA4S0
DIN 25 PN 100, 316 SSTDIN 25 PN 40, 316 SSTDIN 25 PN 16, 316 SST1 in. ANSI Class 2500, RF, SST1 in. ANSI Class 900/1500, RF, SST1 in. ANSI Class 600, RF, SST1 in. ANSI Class 300, RF, SST1 in. ANSI Class 150, RF, SST
Code Flanged Mount
FA4CFA4SFB4CFB4SFC4CFC4SFE4CFE4SFF4CFF4SFJMCFJMSFLMCFLMSFNMCFNMS
1 in. ANSI Class 150, Weld-Neck RF, CS1 in. ANSI Class 150, Weld-Neck RF, SST1 in. ANSI Class 300, Weld-Neck RF, CS1 in. ANSI Class 300, Weld-Neck RF, SST1 in. ANSI Class 600, Weld-Neck RF, CS1 in. ANSI Class 600, Weld-Neck RF, SST1 in. ANSI Class 900/1500, Weld-Neck RF, CS1 in. ANSI Class 900/1500, Weld-Neck RF, SST1 in. ANSI Class 2500, Weld-Neck RF, CS1 in. ANSI Class 2500, Weld-Neck RF, SSTDIN 25 PN 16, CSDIN 25 PN 16, 316 SSTDIN 25 PN 40, CSDIN 25 PN 40, 316 SSTDIN 25 PN 100, CSDIN 25 PN 100, 316 SST
Code Opposite Side Support (Required for Model 16S only)
MS2C0MS2CWMS2S0MS2SW
Contoured Weld Fitting and Plug, ½—14 NPT, CSContoured Weld Fitting and Plug, ½ in. Socket Weld Ports, CSContoured Weld Fitting and Plug, ½—14 NPT, SSTContoured Weld Fitting and Plug, ½ in. Socket Weld Ports, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXR
Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element
Code Optional Calibration
MZ
Lab Flow Calibration (Average K) (<10 in.)Special Calibration
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DFF+15S 020 HAMS0 C0000 FA4S0 FA4C
MODEL DFF+15S/16S
Rosemount Inc.
Diam
ond
II+An
nuba
r®
MODEL DFF+25S/26SModel Product Description
DFF+25SDFF+26S
Diamond II + Annubar® Primary Flow Element - Flanged, SSTDiamond II + Annubar® Primary Flow Element - Flanged with Opposite Side Support, SST
Code Line Size
040050060080100120140160180200240300360420
4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)
Code Head Style
HAMS0HADS0HADSBHADSNHAPS0HAXS0
Direct and Integral Mount Heads - Horizontal LineIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTDirect Mount, Quantity Two, 3-Valve Manifold, Horizontal Line, SST
HATSNHATS0HATSBHATSD
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SST
HVPS0HVMS0HVDS0HVDSBHVDSN
Direct and Integral Mount Heads - Vertical LineDirect Mount, No Manifold, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SST
HVTS0HVTSBHVTSDHVTSN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SSHAHS0HAHSS
Remote Mount - Horizontal LineAxial, Horizontal Line, ½—14 NPT, SSTAxial, Horizontal Line, ½ in. Socket Weld Ports, SSTParallel, Horizontal Line, ½—14 NPT, SSTParallel, Horizontal Line, ½ in. Socket Weld Ports, SSTAxial, HP, Horizontal Line, ½—14 NPT, SSTAxial, HP, Horizontal Line, ½ in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SSHVHS0HVHSS
Remote Mount - Vertical LineParallel, Vertical Line, ½ in. Socket Weld Ports, SSTParallel, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½ in. Socket Weld Ports, SSTAxial, HP, Vertical Line, ½—14 NPT, SSTAxial, HP, Vertical Line, ½ in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valves - CSNeedle Valve, Elbow, ½—14 NPT, CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Elbow and Tee, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS
Flow-411
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Instrument Connections (Continued)
CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS
Needle Valves - SSTNeedle Valve, Elbow, ½—14 NPT, SSTNeedle Valve, Elbow, ½ in. Socket Weld Ports, SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Nipple, ½ in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½ in. Socket Weld Ports, SST
CB2C0CC2C0SB2C0SC2C0SV2C0
Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS
CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS
Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, ½ in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, ½ in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½ in. Socket Weld Ports, SST
Code Sensor Flange
FNPS0FLPS0FJPS0FF8S0FE8S0FC6S0FB6S0FA6S0
DIN 40 PN 100, 316 SSTDIN 40 PN 40, 316 SSTDIN 40 PN 16, 316 SST2 in. ANSI Class 2500, RF, SST2 in. ANSI Class 900/1500, RF, SST1½ in. ANSI Class 600, RF, SST1½ in. ANSI Class 300, RF, SST1½ in. ANSI Class 150, RF, SST
Code Flanged Mount
FA6CFA6SFB6CFB6SFC6CFC6SFE8CFE8SFJPCFJPSFLPCFLPSFNPCFNPS
1½ in. ANSI Class 150, Weld-Neck RF, CS1½ in. ANSI Class 150, Weld-Neck RF, SST1½ in. ANSI Class 300, Weld-Neck RF, CS1½ in. ANSI Class 300, Weld-Neck RF, SST1½ in. ANSI Class 600, Weld-Neck RF, CS1½ in. ANSI Class 600, Weld-Neck RF, SST2 in. ANSI Class 900/1500,Weld-Neck RF, CS2 in. ANSI Class 1500, Weld-Neck RF, SSTDIN 40 PN 16, CSDIN 40 PN 16, 316 SSTDIN 40 PN 40, CSDIN 40 PN 40, 316 SSTDIN 40 PN 100, CSDIN 40 PN 100, 316 SST
Code Opposite Side Support (Required for Model 26S only)
MS4C0MS4CWMS4S0MS4SW
Contoured Weld Fitting and Plug, 1—11.5 NPT, CSContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 1—11.5 NPT, SSTContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRATRPTXATXPTRRTXR
Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
MODEL DFF+25S/26S
12
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Optional Special Assembly
S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DFF+25S 040 HAMS0 C0000 FA6S0 FA6C
MODEL DFF+25S/26S
Flow-413
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
MODEL DFF+25H/26HModel Product Description
DFF+25HDFF+26H
Diamond II + Annubar® Primary Flow Element - Flanged, Hastelloy-CDiamond II + Annubar® Primary Flow Element - Flanged with Opposite Side Support, Hastelloy-C
Code Line Size
040050060080100120140160180200240300360420
4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)
Code Head Style
HADH0HADHBHADHNHAMH0HAPH0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-CIntegral, 3-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, No Manifold, Horizontal Line, Hastelloy-C
HATH0HATHDHATHNHATHB
Direct and Integral Mount Heads - Horizontal Line with RTDIntegral, 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, Hastelloy-C
HVMH0HVDH0HVDHBHVDHNHVPH0
Direct and Integral Mount Heads - Vertical LineIntegral, 3-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, NACE, Vertical Line, Hastelloy-CDirect Mount, No Manifold, Vertical Line, Hastelloy-C
HVTH0HVTHBHVTHDHVTHN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-C
HA2H0HA2HSHP2H0HAHH0HAHHS
Remote Mount - Horizontal LineAxial, Horizontal Line, ½—14 NPT, Hastelloy-CAxial, Horizontal Line, ½ in. Socket Weld Ports, Hastelloy-CParallel, Horizontal Line, ½—14 NPT, Hastelloy-CAxial, HP, Horizontal Line, ½—14 NPT, Hastelloy-CAxial, HP, Horizontal Line, ½ in. Socket Weld Ports, Hastelloy-C
HPVH0HV2H0HVHH0HVHHS
Remote Mount - Vertical LineParallel, Vertical Line, ½—14 NPT, Hastelloy-CAxial, Vertical Line, ½—14 NPT, Hastelloy-CAxial, HP, Vertical Line, ½—14 NPT, Hastelloy-CAxial, HP, Vertical Line, ½ in. Socket Weld Ports, Hastelloy-C
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valves - CSNeedle Valve, Elbow, ½—14 NPT, CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Elbow and Tee, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS
14
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Instrument Connections (Continued)
CA2S0CP2S0SA2S0SP2S0
Needle Valves - SSTNeedle Valve, Elbow, ½—14 NPT, SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Elbow and Tee, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SST
CA2H0CP2H0
Needle Valves - Hastelloy-CNeedle Valve, Elbow, ½—14 NPT, Hastelloy-CNeedle Valve, Nipple, ½—14 NPT, Hastelloy-C
CB2C0CC2C0SB2C0SC2C0SV2C0
Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS
CB2S0CC2S0SB2S0SC2S0SV2S0
Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SST
Code Sensor Flange
FF8H0FE8H0FC6H0FB6H0FA6H0
2 in. ANSI Class 2500, RF, Hastelloy-C2 in. ANSI Class 900/1500, RF, Hastelloy-C1½ in. ANSI Class 600, RF, Hastelloy-C1½ in. ANSI Class 300, RF, Hastelloy-C1½ in. ANSI Class 150, RF, Hastelloy-C
Code Flanged Mount
FA6CFA6SFB6CFB6SFC6CFC6SFE8CFE8S
1½ in. ANSI Class 150, Weld-Neck RF, CS1½ in. ANSI Class 150, Weld-Neck RF, SST1½ in. ANSI Class 300, Weld-Neck RF, CS1½ in. ANSI Class 300, Weld-Neck RF, SST1½ in. ANSI Class 600, Weld-Neck RF, CS1½ in. ANSI Class 600, Weld-Neck RF, SST2 in. ANSI Class 900/1500, Weld-Neck RF, CS2 in. ANSI Class 1500, Weld-Neck RF, SST
Code Opposite Side Support (Required for Model 26H only)
MS4C0MS4CWMS4S0MS4SW
Contoured Weld Fitting and Plug, 1—11.5 NPT, CSContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 1—11.5 NPT, SSTContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRATRPTXATXPTRRTXR
Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
MODEL DFF+25H/26H
Flow-415
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DFF+25H 040 HAMH0 C0000 FA6H0 FA6C
MODEL DFF+25H/26H
16
Rosemount Inc.
Diam
ond
II+An
nuba
r®
MODEL DFF+25M/26MModel Product Description
DFF+25MDFF+26M
Diamond II + Annubar® Primary Flow Element - Flanged, MonelDiamond II + Annubar® Primary Flow Element - Flanged with Opposite Side Support, Monel
Code Line Size
040050060080100120140160180200240300360420
4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)
Code Head Style
HADM0HADMBHADMNHAMM0HAPM0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, MonelIntegral, 3-Valve Manifold, Horizontal Line, MonelDirect Mount, No Manifold, Horizontal Line, Monel
HATM0HATMDHATMNHATMB
Direct and Integral Mount Heads - Horizontal Line with RTDIntegral, 3-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, Monel
HVMM0HVDM0HVDMBHVDMNHVPM0
Direct and Integral Mount Heads - Vertical LineIntegral, 3-Valve Manifold, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, Vertical Line, MonelDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, MonelDirect Mount, 5-Valve Manifold, NACE, Vertical Line, MonelDirect Mount, No Manifold, Vertical Line, Monel
HVTM0HVTMBHVTMDHVTMN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Monel
HA2M0HA2MSHP2M0HAHM0HAHMS
Remote Mount - Horizontal LineAxial, Horizontal Line, ½—14 NPT, MonelAxial, Horizontal Line, ½ in. Socket Weld Ports, MonelParallel, Horizontal Line, ½—14 NPT, MonelAxial, HP, Horizontal Line, ½—14 NPT, MonelAxial, HP, Horizontal Line, ½ in. Socket Weld Ports, Monel
HPVM0HVHM0HVHMSHV2MOHV2MS
Remote Mount - Vertical LineParallel, Vertical Line, ½—14 NPT, MonelAxial, HP, Vertical Line, ½—14 NPT, MonelAxial, HP, Vertical Line, ½ in. Socket Weld Ports, MonelAxial, Vertical Line, ½—14 NPT, MonelAxial, Vertical Line, ½ in. Socket Weld Ports, Monel
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valves - CSNeedle Valve, Elbow, ½—14 NPT, CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Elbow and Tee, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS
Flow-417
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Instrument Connections (Continued)
CA2S0CP2S0SA2S0SP2S0
Needle Valves - SSTNeedle Valve, Elbow, ½—14 NPT, SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Elbow and Tee, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SST
CA2M0CP2M0
Needle Valves - MonelNeedle Valve, Elbow, ½—14 NPT, MonelNeedle Valve, Nipple, ½—14 NPT, Monel
CB2C0CC2C0SB2C0SC2C0SV2C0
Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS
CB2S0CC2S0SB2S0SC2S0SV2S0
Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SST
Code Sensor Flange
FE8M0FF8M0FC6M0FB6M0FA6M0
2 in. ANSI Class 900/1500, RF, Monel2 in. ANSI Class 2500, RF, Monel1½ in. ANSI Class 600, RF, Monel1½ in. ANSI Class 300, RF, Monel1½ in. ANSI Class 150, RF, Monel
Code Flanged Mount
FA6CFA6SFB6CFB6SFC6CFC6SFE8CFE8S
1½ in. ANSI Class 150, Weld-Neck RF, CS1½ in. ANSI Class 150, Weld-Neck RF, SST1½ in. ANSI Class 300, Weld-Neck RF, CS1½ in. ANSI Class 300, Weld-Neck RF, SST1½ in. ANSI Class 600, Weld-Neck RF, CS1½ in. ANSI Class 600, Weld-Neck RF, SST2 in. ANSI Class 900/1500, Weld-Neck RF, CS2 in. ANSI Class 1500, Weld-Neck RF, SST
Code Opposite Side Support (Required for Model 26M only)
MS4C0MS4CWMS4S0MS4SW
Contoured Weld Fitting and Plug, 1—11.5 NPT, CSContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 1—11.5 NPT, SSTContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRATRPTXATXPTRRTXR
Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
MODEL DFF+25M/26M
18
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DFF+25M 040 HAMM0 C0000 FA6M0 FA6C
MODEL DFF+25M/26M
Flow-419
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
MODEL DFF+35S/36SModel Product Description
DFF+35SDFF+36S
Diamond II + Annubar® Primary Flow Element - Flanged, SSTDiamond II + Annubar® Primary Flow Element - Flanged with Opposite Side Support, SST
Code Line Size
080100120140160180200240300360420480600720
8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HAMS0HADS0HADSBHADSNHAPS0HAXS0
Direct and Integral Mount Heads - Horizontal LineIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTDirect Mount, Quantity Two, 3-Valve Manifold, Horizontal Line, SST
HATSNHATS0HATSBHATSD
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SST
HVPS0HVMS0HVDS0HVDSBHVDSN
Direct and Integral Mount Heads - Vertical LineDirect Mount, No Manifold, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SST
HVTS0HVTSBHVTSDHVTSN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SSHAHS0HAHSS
Remote Mount - Horizontal LineAxial, Horizontal Line, ½—14 NPT, SSTAxial, Horizontal Line, ½ in. Socket Weld Ports, SSTParallel, Horizontal Line, ½—14 NPT, SSTParallel, Horizontal Line, ½ in. Socket Weld Ports, SSTAxial, HP, Horizontal Line, ½—14 NPT, SSTAxial, HP, Horizontal Line, ½ in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SSHVHS0HVHSS
Remote Mount - Vertical LineParallel, Vertical Line, ½ in. Socket Weld Ports, SSTParallel, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½ in. Socket Weld Ports, SSTAxial, HP, Vertical Line, ½—14 NPT, SSTAxial, HP, Vertical Line, ½ in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valves - CSNeedle Valve, Elbow, ½—14 NPT, CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Elbow and Tee, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS
20
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Instrument Connections (Continued)
CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS
Needle Valves - SSTNeedle Valve, Elbow, ½—14 NPT, SSTNeedle Valve, Elbow, ½ in. Socket Weld Ports, SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Nipple, ½ in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½ in. Socket Weld Ports, SST
CB2C0CC2C0SB2C0SC2C0SV2C0
Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS
CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS
Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, ½ in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, ½ in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½ in. Socket Weld Ports, SST
Code Sensor Flange
FNRS0FLRS0FJRS0FFDS0FEDS0FDDS0FC8S0FBDS0FA8S0
DIN 50 PN 100, 316 SSTDIN 50 PN 40, 316 SSTDIN 50 PN 16, 316 SST3 in. ANSI Class 2500, RF, SST3 in. ANSI Class 1500, RF, SST3 in. ANSI 900, RF, SST2 in. ANSI Class 600, RF, SST3 in. ANSI Class 300, RF, SST2 in. ANSI Class 150, RF, SST
Code Flanged Mount
FA8CFA8SFB8CFB8SFC8CFC8SFDDCFDDSFEDCFEDSFFDCFFDSFJRCFJRSFLRCFLRSFNRCFNRS
2 in. ANSI Class 150, Weld-Neck RF,CS2 in. ANSI Class 150, Weld-Neck RF, SST2 in. ANSI Class 300, Weld-Neck RF, CS2 in. ANSI Class 300, Weld-Neck RF, SST2 in. ANSI Class 600, Weld-Neck RF, CS2 in. ANSI Class 600, Weld-Neck RF, SST3 in. ANSI Class 900, Weld-Neck RF, CS3 in. ANSI Class 900, Weld-Neck RF, SST3 in. ANSI Class 1500, Weld-Neck RF, CS3 in. ANSI Class 1500, Weld-Neck RF, SST3 in. ANSI Class 2500, Weld-Neck RF, CS3 in. ANSI Class 2500, Weld-Neck RF, SSTDIN 50 PN 16, CSDIN 50 PN 16, 316 SSTDIN 50 PN 40, CSDIN 50 PN 40, 316 SSTDIN 50 PN 100, CSDIN 50 PN 100, 316 SST
Code Opposite Side Support (Required for Model 36S only)
MS6C0MS6CWMS6S0MS6SW
Contoured Weld Fitting and Plug, 1½—11.5 NPT, CSContoured Weld Fitting and Plug, 1½ in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 1½—11.5 NPT, SSTContoured Weld Fitting and Plug, 1½ in. Socket Weld Ports, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRATRPTXATXPTRRTXR
Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
MODEL DFF+35S/36S
Flow-421
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Optional Special Assembly
S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DFF+35S 080 HAMS0 C0000 FA8S0 FA8C
MODEL DFF+35S/36S
22
Rosemount Inc.
Diam
ond
II+An
nuba
r®
MODEL DFF+45S/46SModel Product Description
DFF+45SDFF+46S
Diamond II + Annubar® Primary Flow Element - Flanged, SSTDiamond II + Annubar® Primary Flow Element - Flanged with Opposite Side Support, SST
Code Line Size
100120140160180200240300360420480600720
10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HAMS0HADS0HADSBHADSNHAPS0HAXS0
Direct and Integral Mount Heads - Horizontal LineIntegral, 3-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTDirect Mount, Quantity Two, 3-Valve Manifold, Horizontal Line, SST
HATSNHATS0HATSBHATSD
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SST
HVPS0HVMS0HVDS0HVDSBHVDSN
Direct and Integral Mount Heads - Vertical LineDirect Mount, No Manifold, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SST
HVTS0HVTSBHVTSDHVTSN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SSHAHS0HAHSSHSHS0
Remote Mount - Horizontal LineAxial, Horizontal Line, ½—14 NPT, SSTAxial, Horizontal Line, ½ in. Socket Weld Ports, SSTParallel, Horizontal Line, ½—14 NPT, SSTParallel, Horizontal Line, ½ in. Socket Weld Ports, SSTAxial, HP, Horizontal Line, ½—14 NPT, SSTAxial, HP, Horizontal Line, ½ in. Socket Weld Ports, SSTStack Head with Purge, Horizontal Line, ½—14 NPT, SST
HPVS0HPVSSHV2S0HV2SSHVHS0HVHSSHSVS0
Remote Mount - Vertical LineParallel, Vertical Line, ½ in. Socket Weld Ports, SSTParallel, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½ in. Socket Weld Ports, SSTAxial, HP, Vertical Line, ½—14 NPT, SSTAxial, HP, Vertical Line, ½ in. Socket Weld Ports, SSTStack Head with Purge, Vertical Line, ½—14 NPT, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0
Needle Valves - CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS
Flow-423
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Instrument Connections (Continued)
CP2S0SP2S0CP2SSSP2SS
Needle Valves - SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SSTNeedle Valve, Nipple, ½ in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, ½ in. Socket Weld Ports, SST
CC2S0SC2S0SV2S0CB2SSCC2SSSV2SS
Gate Valves - SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, ½ in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, ½ in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½ in. Socket Weld Ports, SST
Code Sensor Flange
FNTS0FLTS0FJTS0FFDS0FEDS0FDDS0FCDS0FBDS0FADS0
DIN 80 PN 100, 316 SSTDIN 80 PN 40, 316 SSTDIN 80 PN 16, 316 SST3 in. ANSI Class 2500, RF, SST3 in. ANSI Class 1500, RF, SST3 in. ANSI Class 900, RF, SST3 in. ANSI Class 600, RF, SST3 in. ANSI Class 300, RF, SST3 in. ANSI Class 150, RF, SST
Code Flanged Mount
FDDCFDDSFFDCFFDSFADCFADSFBDCFBDSFCDCFCDSFJTCFJTSFLTCFLTSFNTCFNTS
3 in. ANSI Class 900, Weld-Neck RF, CS3 in. ANSI Class 900, Weld-Neck RF, SST3 in. ANSI Class 2500, Weld-Neck RF, CS3 in. ANSI Class 2500, Weld-Neck RF, SST3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600, Weld-Neck RF, CS3 in. ANSI Class 600, Weld-Neck RF, SSTDIN 80 PN 16, CSDIN 80 PN 16, 316 SSTDIN 80 PN 40, CSDIN 80 PN 40, 316 SSTDIN 80 PN 100, CSDIN 80 PN 100, 316 SST
Code Opposite Side Support (Required for Model 46S only)
MSDCWMSDSW
Contoured Weld Fitting and Cap, 3 in., BW, CSContoured Weld Fitting and Cap, 3 in., BW, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRATRPTXATXPTRRTXR
Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
MODEL DFF+45S/46S
24
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DFF+45S 240 HAMS0 C0000 FADS0 FADC
MODEL DFF+45S/46S
Flow-425
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
MODEL DFF+45H/46HModel Product Description
DFF+45HDFF+46H
Diamond II + Annubar® Primary Flow Element - Flanged, Hastelloy-CDiamond II + Annubar® Primary Flow Element - Flanged with Opposite Side Support, Hastelloy-C
Code Line Size
100120140160180200240300360420480600720
10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HADH0HADHBHADHNHAMH0HAPH0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-CIntegral, 3-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, No Manifold, Horizontal Line, Hastelloy-C
HATH0HATHDHATHNHATHB
Direct and Integral Mount Heads - Horizontal Line with RTDIntegral, 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, Hastelloy-C
HVMH0HVDH0HVDHBHVDHNHVPH0
Direct and Integral Mount Heads - Vertical LineIntegral, 3-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, NACE, Vertical Line, Hastelloy-CDirect Mount, No Manifold, Vertical Line, Hastelloy-C
HVTH0HVTHBHVTHDHVTHN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-C
HA2H0HA2HSHP2H0HAHH0HAHHS
Remote Mount - Horizontal LineAxial, Horizontal Line, ½—14 NPT, Hastelloy-CAxial, Horizontal Line, ½ in. Socket Weld Ports, Hastelloy-CParallel, Horizontal Line, ½—14 NPT, Hastelloy-CAxial, HP, Horizontal Line, ½—14 NPT, Hastelloy-CAxial, HP, Horizontal Line, ½ in. Socket Weld Ports, Hastelloy-C
HPVH0HV2H0HVHH0HVHHSHSVH0
Remote Mount - Vertical LineParallel, Vertical Line, ½—14 NPT, Hastelloy-CAxial, Vertical Line, ½—14 NPT, Hastelloy-CAxial, HP, Vertical Line, ½—14 NPT, Hastelloy-CAxial, HP, Vertical Line, ½ in. Socket Weld Ports, Hastelloy-CStack Head with Purge, Vertical Line, ½—14 NPT, Hastelloy-C
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0
Needle Valves - CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS
CP2S0SP2S0
Needle Valves - SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SST
CP2H0Needle Valves - Hastelloy-CNeedle Valve, Nipple, ½—14 NPT, Hastelloy-C
26
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Instrument Connections (Continued)
CC2C0SC2C0SV2C0
Gate Valves - CSOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS
CC2S0SC2S0SV2S0
Gate Valves - SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SST
Code Sensor Flange
FDDH0FFDH0FEDH0FCDH0FBDH0FADH0
3 in. ANSI Class 900, RF, Hastelloy-C3 in. ANSI Class 2500, RF, Hastelloy-C3 in. ANSI Class 1500, RF, Hastelloy-C3 in. ANSI Class 600, RF, Hastelloy-C3 in. ANSI Class 300, RF, Hastelloy-C3 in. ANSI Class 150, RF, Hastelloy-C
Code Flanged Mount
FDDCFDDSFFDCFFDSFADCFADSFBDCFBDSFCDCFCDS
3 in. ANSI Class 900, Weld-Neck RF, CS3 in. ANSI Class 900, Weld-Neck RF, SST3 in. ANSI Class 2500, Weld-Neck RF, CS3 in. ANSI Class 2500, Weld-Neck RF, SST3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600,Weld-Neck RF, CS3 in. ANSI Class 600,Weld-Neck RF, SST
Code Opposite Side Support (Required for Model 46H only)
MSDCWMSDSW
Contoured Weld Fitting and Cap, 3 in., BW, CSContoured Weld Fitting and Cap, 3 in., BW, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRATRPTXATXPTRRTXR
Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DFF+45H 240 HAMH0 C0000 FADH0 FADC
MODEL DFF+45H/46H
Flow-427
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
MODEL DFF+45M/46MModel Product Description
DFF+45MDFF+46M
Diamond II + Annubar® Primary Flow Element - Flanged, MonelDiamond II + Annubar® Primary Flow Element - Flanged with Opposite Side Support, Monel
Code Line Size
100120140160180200240300360420480600720
10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HADM0HADMBHADMNHAMM0HAPM0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, MonelIntegral, 3-Valve Manifold, Horizontal Line, MonelDirect Mount, No Manifold, Horizontal Line, Monel
HATM0HATMDHATMNHATMB
Direct and Integral Mount Heads - Horizontal Line with RTDIntegral, 3-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, Monel
HVMM0HVDM0HVDMBHVDMNHVPM0
Direct and Integral Mount Heads - Vertical LineIntegral, 3-Valve Manifold, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, Vertical Line, MonelDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, MonelDirect Mount, 5-Valve Manifold, NACE, Vertical Line, MonelDirect Mount, No Manifold, Vertical Line, Monel
HVTM0HVTMBHVTMDHVTMN
Direct and Integral Mount Heads - Vertical Line with RTDIntegral, 3-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Monel
HA2M0HA2MSHP2M0HAHM0HAHMS
Remote Mount - Horizontal LineAxial, Horizontal Line, ½—14 NPT, MonelAxial, Horizontal Line, ½ in. Socket Weld Ports, MonelParallel, Horizontal Line, ½—14 NPT, MonelAxial, HP, Horizontal Line, ½—14 NPT, MonelAxial, HP, Horizontal Line, ½ in. Socket Weld Ports, Monel
HPVS0HPVSSHV2S0HV2SSHVHS0HVHSS
Remote Mount - Vertical LineParallel, Vertical Line, ½ in. Socket Weld Ports, SSTParallel, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½—14 NPT, SSTAxial, Vertical Line, ½ in. Socket Weld Ports, SSTAxial, HP, Vertical Line, ½—14 NPT, SSTAxial, HP, Vertical Line, ½ in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0
Needle Valves - CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS
CP2S0SP2S0
Needle Valves - SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SST
28
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Instrument Connections (Continued)
CP2M0Needle Valves - MonelNeedle Valve, Nipple, ½—14 NPT, Monel
CC2C0SC2C0SV2C0
Gate Valves - CSOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS
CC2S0SC2S0SV2S0
Gate Valves - SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SST
Code Sensor Flange
FFDM0FEDM0FCDM0FBDM0FADM0
3 in. ANSI Class 2500, RF, Monel3 in. ANSI Class 1500, RF, Monel3 in. ANSI Class 600, RF, Monel3 in. ANSI Class 300, RF, Monel3 in. ANSI Class 150, RF, Monel
Code Flanged Mount
FDDCFDDSFFDCFFDSFADCFADSFBDCFBDSFCDCFCDS
3 in. ANSI Class 900, Weld-Neck RF, CS3 in. ANSI Class 900, Weld-Neck RF, SST3 in. ANSI Class 2500, Weld-Neck RF, CS3 in. ANSI Class 2500, Weld-Neck RF, SST3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600, Weld-Neck RF, CS3 in. ANSI Class 600, Weld-Neck RF, SST
Code Opposite Side Support (Required for Model 46M only)
MSDCWMSDSW
Contoured Weld Fitting and Cap, 3 in., BW, CSContoured Weld Fitting and Cap, 3 in., BW, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRATRPTXATXPTRRTXR
Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, Explosion, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of Rosemount DP Transmitter to DP Primary Element
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DFF+45M 240 HAMM0 C0000 FADM0 FADC
MODEL DFF+45M/46M
Flow-429
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
30
Diam
ond
II+An
nuba
r®
Rosemount Inc.
Flow-431
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
32
Diam
ond
II+An
nuba
r®
Rosemount Inc.
Flow-433
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Ordering Information—Model DPFMODELS DPF+15S/16S
Model Product Description
DPF+15SDPF+16S
Diamond II + Annubar® Primary Flow Element - Pak-Lok FlangedDiamond II + Annubar® Primary Flow Element - Pak-Lok Flanged with Opposite Side Support
Code Line Size
020025030035040050
2 in. (50 mm)21/2 in. (63.5 mm)3 in. (80 mm)31/2 in. (89 mm)4 in. (100 mm)5 in. (125 mm)
Code Head Style
HVPS0Direct and Integral Mount Head - Vertical LineDirect Mount, No Manifold, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0CA2C0SA2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SSCP2S0SP2S0CP2SSSP2SSCA2S0SA2S0
Needle Valve - SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple,1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SST
CC2C0SC2C0CB2C0SB2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT,CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CC2S0SC2S0CB2SSCC2SSSV2SSCB2S0SB2S0SV2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT,SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
34
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Pak-Lok Sensor Flange
PA4C2PA4S2PB4C2PB4S2PC4C2PC4S2
Pak-Lok Flange, 1 in. ANSI Class 150, RF, CSPak-Lok Flange, 1 in. ANSI Class 150, RF, SSTPak-Lok Flange, 1 in. ANSI Class 300, RF, CSPak-Lok Flange, 1 in. ANSI Class 300, RF, SSTPak-Lok Flange, 1 in. ANSI Class 600, RF, CSPak-Lok Flange, 1 in. ANSI Class 600, RF, SST
Code Flanged Mounting
FA4CFA4SFB4CFB4SFC4CFC4S
1 in. ANSI Class 150, Weld-Neck RF, CS1 in. ANSI Class 150, Weld-Neck RF, SST1 in. ANSI Class 300, Weld-Neck RF, CS1 in. ANSI Class 300, Weld-Neck RF, SST1 in. ANSI Class 600, Weld-Neck RF, CS1 in. ANSI Class 600, Weld-Neck RF, SST
Code Opposite Side Support (Required for Model 16S only)
MS2C0MS2CWMS2S0MS2SW
Contoured Weld Fitting and Plug, 1/2—14 NPT, CSContoured Weld Fitting and Plug, 1/2 in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 1/2—14 NPT, SSTContoured Weld Fitting and Plug, 1/2 in. Socket Weld Ports, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXR
Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
MZ
Lab Flow Calibration (Average K) (<10 in.)Special Calibration
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: DPF+15S 020 HA2S0 CP2C0 PA4C2 FA4C
MODELS DPF+15S/16S
Flow-435
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
MODELS DPF+25S/26SModel Product Description
DPF+25SDPF+26S
Diamond II + Annubar® Primary Flow Element - Pak-Lok FlangedDiamond II + Annubar®Primary Flow Element - Pak-Lok Flanged with Opposite Side Support
Code Line Size
040050060080100120140160180200240300360420
4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)
Code Head Style
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0CA2C0SA2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SSCP2S0SP2S0CP2SSSP2SSCA2S0SA2S0
Needle Valve - SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple,1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SST
CC2C0SC2C0CB2C0SB2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT,CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CC2S0SC2S0CB2SSCC2SSSV2SSCB2S0SB2S0SV2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT,SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
36
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Pak-lok Sensor Flange
PA6C4PA6S4PB6C4PB6S4PC6C4PC6S4
Pak-Lok Flange, 11/2 in. ANSI Class 150, RF, CSPak-Lok Flange, 11/2 in. ANSI Class 150, RF, SSTPak-Lok Flange, 11/2 in. ANSI Class 300, RF, CSPak-Lok Flange, 11/2 in. ANSI Class 300, RF, SSTPak-Lok Flange, 11/2 in. ANSI Class 600, RF, CSPak-Lok Flange, 11/2 in. ANSI Class 600, RF, SST
Code Flanged Mounting
FA6CFA6SFB6CFB6SFC6CFC6S
11/2 in. ANSI Class 150, Weld-Neck RF, CS11/2 in. ANSI Class 150, Weld-Neck RF, SST11/2 in. ANSI Class 300, Weld-Neck RF, CS11/2 in. ANSI Class 300, Weld-Neck RF, SST11/2 in. ANSI Class 600, Weld-Neck RF, CS11/2 in. ANSI Class 600, Weld-Neck RF, SST
Code Opposite Side Support (Required for Model 26S only)
MS4C0MS4CWMS4S0MS4SW
Contoured Weld Fitting and Plug, 1—11.5 NPT, CSContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 1—11.5 NPT, SSTContoured Weld Fitting and Plug, 1 in. Socket Weld Ports, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, Parallel
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: DPF+25S 040 HA2S0 CP2C0 PA6C4 FA6C
MODELS DPF+25S/26S
Flow-437
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
MODELS DPF+35S/36SModel Product Description
DPF+35SDPF+36S
Diamond II + Annubar® Primary Flow Element - Pak-Lok FlangedDiamond II + Annubar® Primary Flow Element - Pak-Lok Flanged with Opposite Side Support
Code Line Size
080100120140160180200240300360420480600720
8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0CA2C0SA2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SSCP2S0SP2S0CP2SSSP2SSCA2S0SA2S0
Needle Valve - SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple,1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SST
CC2C0SC2C0CB2C0SB2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT,CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CC2S0SC2S0CB2SSCC2SSSV2SSCB2S0SB2S0SV2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT,SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
38
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Pak-Lok Sensor Flange
PA8C6PA8S6PB8C6PB8S6PC8C6PC8S6
Pak-Lok Flange, 2 in. ANSI Class 150, RF, CSPak-Lok Flange, 2 in. ANSI Class 150, RF, SSTPak-Lok Flange, 2 in. ANSI Class 300, RF, CSPak-Lok Flange, 2 in. ANSI Class 300, RF, SSTPak-Lok Flange, 2 in. ANSI Class 600, RF, CSPak-Lok Flange, 2 in. ANSI Class 600, RF, SST
Code Flanged Mount
FA8CFA8SFB8CFB8SFC8CFC8S
2 in. ANSI Class 150, Weld-Neck RF, CS2 in. ANSI Class 150, Weld-Neck RF, SST2 in. ANSI Class 300, Weld-Neck RF, CS2 in. ANSI Class 300, Weld-Neck RF, SST2 in. ANSI Class 600, Weld-Neck RF, CS2 in. ANSI Class 600, Weld-Neck RF, SST
Code Opposite Side Support (Required for Model 36S only)
MS6C0MS6CWMS6S0MS6SW
Contoured Weld Fitting and Plug, 11/2—11.5 NPT, CSContoured Weld Fitting and Plug, 11/2 in. Socket Weld Ports, CSContoured Weld Fitting and Plug, 11/2—11.5 NPT, SSTContoured Weld Fitting and Plug, 11/2 in. Socket Weld Ports, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, Parallel
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: DPF+35S 120 HA2S0 CP2C0 PA8C6 FA8C
MODELS DPF+35S/36S
Flow-439
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
MODELS DPF+45S/46SModel Product Description
DPF+45SDPF+46S
Diamond II + Annubar® Primary Flow Element - Pak-Lok FlangedDiamond II + Annubar® Primary Flow Element - Pak-Lok Flanged with Opposite Side Support
Code Line Size
100120140160180200240300360420480600720
10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. (1520 mm)72 in. (1820 mm)
Code Head Style
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0CA2C0SA2C0
Needle Valve - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CS
CA2SSCP2S0SP2S0CP2SSSP2SSCA2S0SA2S0
Needle Valve - SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple,1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SST
CC2C0SC2C0CB2C0SB2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT,CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CC2S0SC2S0CB2SSCC2SSSV2SSCB2S0SB2S0SV2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT,SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
40
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Pak-Lok Sensor Flange
PADCDPADSDPBDCDPBDSDPCDCDPCDSD
Pak-Lok Flange, 3 in. ANSI Class 150, RF, CSPak-Lok Flange, 3 in. ANSI Class 150, RF, SSTPak-Lok Flange, 3 in. ANSI Class 300, RF, CSPak-Lok Flange, 3 in. ANSI Class 300, RF, SSTPak-Lok Flange, 3 in. ANSI Class 600, RF, CSPak-Lok Flange, 3 in. ANSI Class 600, RF, SST
Code Flanged Mount
FADCFADSFBDCFBDSFCDCFCDS
3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600, Weld-Neck RF, CS3 in. ANSI Class 600, Weld-Neck RF, SST
Code Opposite Side Support (Required for Model 46S only)
MSDCWMSDSW
Contoured Weld Fitting and Cap, 3 in., BW, CSContoured Weld Fitting and Cap, 3 in., BW, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, Parallel
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: DPF+45S 240 HA2S0 CP2C0 PADCD FADC
MODELS DPF+45S/46S
Flow-441
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
42
Diam
ond
II+An
nuba
r®
Rosemount Inc.
Flow-443
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
44
Diam
ond
II+An
nuba
r®
Rosemount Inc.
Flow-445
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Ordering Information—Model DNTMODEL DNT+10S
Model Product Description
DNT+10S Diamond II + Annubar® Primary Flow Element - In-line Threaded
Code Line Size
005007010012015020
1/2 in. (12.5 mm)3/4 in. (19 mm)1 in. (25 mm)11/4 in. (31 mm)11/2 in. (37.5 mm)2 in. (50 mm)
Code Fittings
HADS0HADSBHADSNHAPS0HAMS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST
HVDS0HVDSBHVDSNHVPS0HVMS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST
HF1SSHM1S0
Remote MountFittings, 1/4 in. Socket Weld Ports, SSTFittings, 1/4 in., MNPT, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP1C0CP1S0SB1C0SB1S0SP1C0SP1S0
Needle Valve, Nipple, 1/4—18 NPT, CSNeedle Valve, Nipple, 1/4—18 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, SSTNeedle Valve, Nipple and Tee, 1/4—18 NPT, CSNeedle Valve, Nipple and Tee, 1/4—18 NPT, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXR
Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP Primary
Code Optional Calibration
MZ
Lab Flow Calibration (Average K) (<10 in.)Special Calibration
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: DNT+10S 010 HAMS0 HF1SS C0000
46
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Ordering Information—Model DNFMODEL DNF+10S
Model Product Description
DNF+10S Diamond II + Annubar® Primary Flow Element - In-line Flanged
Code Line Size
005007010012015020
1/2 in. (12.5 mm)3/4 in. (19 mm)1 in. (25 mm)11/4 in. (31 mm)11/2 in. (37.5 mm)2 in. (50 mm)
Code Fittings
HADS0HADSBHADSNHAPS0HAMS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST
HVDS0HVDSBHVDSNHVPS0HVMS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST
HF1SSHM1S0
Remote MountFittings, 1/4 in. Socket Weld Ports, SSTFittings, 1/4 in. MNPT, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP1C0CP1S0SB1C0SB1S0SP1C0SP1S0
Needle Valve, Nipple, 1/4—18 NPT, CSNeedle Valve, Nipple, 1/4—18 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, SSTNeedle Valve, Nipple and Tee, 1/4—18 NPT, CSNeedle Valve, Nipple and Tee, 1/4—18 NPT, SST
Code Flanged Mount
FASFBSFCSFJSFLSFNS
ANSI Class 150, Weld-Neck RF, SSTANSI Class 300, Weld-Neck RF, SSTANSI Class 600, Weld-Neck RF, SSTDIN PN 16, SSTDIN PN 40, SSTDIN PN 100, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXR
Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
BS
Lab Flow Calibration (Average K) (<10 in.)Special Calibration
Flow-447
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
48
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: DNF+10S 010 HAMS0 HF1SS C0000 FAS
MODEL DNF+10S
Rosemount Inc.
-449
Diam
ond
II+An
nuba
r®
Flow
MODEL DNF+10HModel Product Description
DNF+10H Diamond II + Annubar® Primary Flow Element - In-line Flanged
Code Line Size
005007010012015020
1/2 in. (12.5 mm)3/4 in. (19 mm)1 in. (25 mm)11/4 in. (31 mm)11/2 in. (37.5 mm2 in. (50 mm)
Code Fittings
HADH0HADHBHADHNHAPH0HAMH0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-CDirect Mount, No Manifold, Horizontal Line, Hastelloy-CIntegral, 3-Valve Manifold, Horizontal Line, Hastelloy-C
HVDH0HVDHBHVDHNHVPH0HVMH0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, NACE, Vertical Line, Hastelloy-CDirect Mount, No Manifold, Vertical Line, Hastelloy-CIntegral, 3-Valve Manifold, Vertical Line, Hastelloy-C
HM1H0Remote MountFittings, 1/4 in., MNPT, Hastelloy-C
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP1C0CP1S0SB1C0SB1S0SP1C0SP1S0
Needle Valve, Nipple, 1/4—18 NPT, CSNeedle Valve, Nipple, 1/4—18 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, SSTNeedle Valve, Nipple and Tee, 1/4—18 NPT, CSNeedle Valve, Nipple and Tee, 1/4—18 NPT, SST
Code Flanged Mount
FAHFBHFCH
ANSI Class 150, Weld-Neck RF, Hastelloy-CANSI Class 300, Weld-Neck RF, Hastelloy-CANSI Class 600, Weld-Neck RF, Hastelloy-C
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXR
Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
MZ
Lab Flow Calibration (Average K) (<10 in.)Special Calibration
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: DNF+10H 010 HAMH0 C0000 FAH
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
MODEL DNF+10MModel Product Description
DNF+10M Diamond II + Annubar® Primary Flow Element - In-line Flanged
Code Line Size
005007010012015020
1/2 in. (12.5 mm)3/4 in. (19 mm)1 in. (25 mm)11/4 in. (31 mm)11/2 in. (37.5 mm)2 in. (50 mm)
Code Fittings
HADM0HADMBHADMNHAMM0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, MonelIntegral, with 3-Valve Manifold, Horizontal Line, Monel
HVDM0HVDMBHVDMNHVMM0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, MonelIntegral, with 3-Valve Manifold, Vertical Line, Monel
HM1M0CP1C0CP1S0SB1C0SB1S0SP1C0SP1S0
Remote MountFittings, 1/4 in. MNPT, MonelNeedle Valve, Nipple, 1/4—18 NPT, CSNeedle Valve, Nipple, 1/4—18 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, SSTNeedle Valve, Nipple and Tee, 1/4—18 NPT, CSNeedle Valve, Nipple and Tee, 1/4—18 NPT, SST
Code Flanged Mount
FAMFBMFCM
ANSI Class 150, Weld-Neck RF, MonelANSI Class 300, Weld-Neck RF, MonelANSI Class 600, Weld-Neck RF, Monel
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXR
Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
MZ
Lab Flow Calibration (Average K) (<10 in.)Special Calibration
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: DNF+10M 010 HAMM0 C0000 FAM
50
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Ordering Information—Model DNWMODEL DNW+10S
Model Product Description
DNW+10S Diamond II + Annubar® Primary Flow Element - In-line Butt Weld
Code Line Size
005007010012015020
1/2 in. (12.5 mm)3/4 in. (19 mm)1 in. (25 mm)11/4 in. (31 mm)11/2 in. (37.5 mm)2 in. (50 mm)
Code Fittings
HADS0HADSBHADSNHAPS0HAMS0
Direct and Integral Mount Heads - Horizontal LIneDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, 3-Valve Manifold, Horizontal Line, SST
HVDS0HVDSBHVDSNHVPS0HVMS0
Direct and Integral Mount Heads - Vertical LIneDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Direct, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SST
HF1SSHM1S0
Remote MountFittings, 1/4 in. Socket Weld Ports, SSTFittings, 1/4 in., MNPT, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP1C0CP1S0SB1C0SB1S0SP1C0SP1S0
Needle Valve, Nipple, 1/4—18 NPT, CSNeedle Valve, Nipple, 1/4—18 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/4—18 NPT, SSTNeedle Valve, Nipple and Tee, 1/4—18 NPT, CSNeedle Valve, Nipple and Tee, 1/4—18 NPT, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXR
Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP Primary
Code Optional Calibration
MZ
Lab Flow Calibration (Average K) (<10 in.)Special Calibration
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: DNW+10S 010 HAMS0 C0000
Flow-451
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
52
Diam
ond
II+An
nuba
r®
Rosemount Inc.
Flow-453
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
54
Diam
ond
II+An
nuba
r®
Rosemount Inc.
Flow-455
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Ordering Information—Model DMTMODEL DMT+15S
Model Product Description
DMT+15S Diamond II + Annubar® Primary Flow Element - Threaded Flo-Tap, Medium Pressure
Code Line Size
020025030035040050
2 in. (50 mm)21/2 in. (63.5 mm)3 in. (80 mm)31/2 in. (89 mm)4 in. (100 mm)5 in. (125 mm)
Code Head Style
HADS0HADSBHADSNHAPS0HAMS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST
HVDS0HVDSBHVDSNHVPS0HVMS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valves - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS
Needle Valves - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
CB2C0CC2C0SB2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
56
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Instrument Connections (Continued)
CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
Code Packing Gland
GR3S0GR3C0GM3S0GM3C0
Graphite, 3/4—14 NPT, SSTGraphite, 3/4—14 NPT, CSUrethane, 3/4—14 NPT, SSTUrethane, 3/4—14 NPT, CS
Code Insert/Retract
IMRSIMRCIMDSIMDC
Manual, Single, SST RodManual, Single, CS RodWheel, Single, SST RodWheel, Single, CS Rod
Code Isolation Valves
VT3SGVT3SBVT3CGVT3CB
Gate Valve, 3/4—14 NPT, SSTBall Valve, 3/4—14 NPT, SSTGate Valve, 3/4—14 NPT, CSBall Valve, 3/4—14 NPT, CS
Code Mounting Hardware
MH3C0MH3S0
Weld Coupling and Nipple, 3/4—14 NPT, CSWeld Coupling and Nipple, 3/4—14 NPT, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, Parallel
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
MZ
Lab Flow Calibration (Average K) (<10 in.)Special Calibration
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: DMT+15S 020 HAMS0 C0000 GR350 IMRS VT3SG MH3C0
MODEL DMT+15S
Flow-457
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
MODEL DMT+25SModel Product Description
DMT+25S Diamond II + Annubar® Primary Flow Element - Threaded Flo-Tap, Medium Pressure
Code Line Size
040050060080100120140160180200240300360420
4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)
Code Head Style
HADS0HADSBHADSNHAMS0HAPS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SST
HATSNHATSBHATSDHATS0
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTIntegral, with 3-Valve Manifold, RTD, Horizontal Line, SST
HVDS0HVDSBHVDSNHVPS0HVMS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST
HVTSBHVTSDHVTSNHVTS0
Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, with 3-Valve Manifold, RTD, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valve - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
58
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Instrument Connections (Continued)
CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS
Needle Valve - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
CB2C0CC2C0SB2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
Code Packing Gland
GR5S0GR5C0GM5S0GM5C0
Graphite, 11/4—11.5 NPT, SSTGraphite, 11/4—11.5 NPT, CSUrethane, 11/4—11.5 NPT, SSTUrethane, 11/4—11.5 NPT, CS
Code Insert/Retract
IMRSIMRCIMDSIMDC
Manual, Single, SST RodManual, Single, CS RodWheel, Single, SST RodWheel, Single, CS Rod
Code Isolation Valve
VT5SGVT5SBVT5CGVT5CB
Gate Valve, 11/4—11.5 NPT, SSTBall Valve, 11/4—11.5 NPT, SSTGate Valve, 11/4—11.5 NPT, CSBall Valve, 11/4—11.5 NPT, CS
Code Mounting Hardware
MH5C0MH5S0
Weld Coupling and Nipple, 11/4—11.5 NPT, CSWeld Coupling and Nipple, 11/4—11.5 NPT, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, Parallel
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
MODEL DMT+25S
Flow-459
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: DMT+25S 040 HAMS0 C0000 GR5S0 IMRS VT5SG MH5C0
MODEL DMT+25S
60
Rosemount Inc.
Diam
ond
II+An
nuba
r®
MODEL DMT+35SModel Product Description
DMT+35S Diamond II + Annubar® Primary Flow Element - Threaded Flo-Tap, Medium Pressure
Code Line Size
080100120140160180200240300360420480600720
8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HADS0HADSBHADSNHAMS0HAPS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SST
HATSNHATSBHATSDHATS0
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTIntegral, with 3-Valve Manifold, RTD, Horizontal Line, SST
HVDS0HVDSBHVDSNHVPS0HVMS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST
HVTSBHVTSDHVTSNHVTS0
Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, with 3-Valve Manifold, RTD, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valve - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
Flow-461
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Instrument Connections (Continued)
CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS
Needle Valve - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
CB2C0CC2C0SB2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
Code Packing Gland
GR8S0GR8C0GM8S0GM8C0
Graphite, 2—11.5 NPT, SSTGraphite, 2—11.5 NPT, CSUrethane, 2—11.5 NPT, SSTUrethane, 2—11.5 NPT, CS
Code Insert/Retract
IMRSIMRCIMDSIMDC
Manual, Single, SST RodManual, Single, CS RodWheel, Single, SST RodWheel, Single, CS Rod
Code Isolation Valves
VT8SGVT8SBVT8CGVT8CB
Gate Valve, 2—11.5 NPT, SSTBall Valve, 2—11.5 NPT, SSTGate Valve, 2—11.5 NPT, CSBall Valve, 2—11.5 NPT, CS
Code Mounting Hardware
MH8C0MH8S0
Weld Coupling and Nipple, 2—11.5 NPT, CSWeld Coupling and Nipple, 2—11.5 NPT, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, Parallel
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
MODEL DMT+35S
62
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: DMT+35S 240 HAMS0 C0000 GR8S0 IMDS VT8SG MH8C0
MODEL DMT+35S
Flow-463
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
64
Diam
ond
II+An
nuba
r®
Rosemount Inc.
Flow-465
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
66
Diam
ond
II+An
nuba
r®
Rosemount Inc.
Flow-467
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
68
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Ordering Information—Model DHTMODEL DHT+15S
Model Product Description
DHT+15S Diamond II + Annubar® Primary Flow Element - Threaded Flo-Tap, High Pressure
Code Line Size
020025030035040050
2 in. (50 mm)21/2 in. (63.5 mm)3 in. (80 mm)31/2 in. (89 mm)4 in. (100 mm)5 in. (125 mm)
Code Head Style
HADS0HADSBHADSNHAPS0HAMS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST
HVDS0HVDSBHVDSNHVPS0HVMS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valves - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS
Needle Valves - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
CB2C0CC2C0
Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
SB2C0SC2C0SV2C0
Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Flow-469
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Instrument Connections (Continued)
CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS
Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
Code Packing Gland
GV3S0GV3C0GH3S0GH3C0
Graphite, 3/4—14 NPT, SSTGraphite, 3/4—14 NPT, CSUrethane, 3/4—14 NPT, SSTUrethane, 3/4—14 NPT, CS
Code Insert/Retract
IHRSIHRC
Manual, Dual, SST RodsManual, Dual, CS Rods
Code Isolation Valves
VT3SGVT3SBVT3CGVT3CB
Gate Valve, 2—11.5 NPT, SSTBall Valve, 2—11.5 NPT, SSTGate Valve, 2—11.5 NPT, CSBall Valve, 2—11.5 NPT, CS
Code Mounting Hardware
MH3C0MH3S0
Weld Coupling and Nipple, 3/4—14 NPT, CSWeld Coupling and Nipple, 3/4—14 NPT, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXR
Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
MZ
Lab Flow Calibration (Average K) (<10 in.)Special Calibration
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: DHT+15S 020 HAMS0 C0000 GV3S0 IHRS VT3SG MH3C0
MODEL DHT+15S
70
Rosemount Inc.
Diam
ond
II+An
nuba
r®
MODEL DHT+25SModel Product Description
DHT+25S Diamond II + Annubar® Primary Flow Element - Threaded Flo-Tap, High Pressure
Code Line Size
040050060080100120140160180200240300360420
4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)
Code Head Style
HADS0HADSBHADSNHAPS0HAMS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST
HATSBHATSDHATSNHATS0
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, with 3-Valve Manifold, RTD, Horizontal Line, SST
HVDS0HVDSBHVDSNHVPS0HVMS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST
HVTSBHVTSDHVTSNHVTS0
Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, with 3-Valve Manifold, RTD, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valves - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
Flow-471
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Instrument Connections (Continued)
CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS
Needle Valves - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
CB2C0CC2C0SB2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
Code Packing Gland
GV5S0GV5C0GH5S0GH5C0
Graphite, 11/4—11.5 NPT, SSTGraphite, 11/4—11.5 NPT, CSUrethane, 11/4—11.5 NPT, SSTUrethane, 11/4—11.5 NPT, CS
Code Insert/Retract
IHRSIHRCIHDS
Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST Rods
Code Isolation Valves
VT5SGVT5SBVT5CGVT5CB
Gate Valve, 11/4—11.5 NPT, SSTBall Valve, 11/4—11.5 NPT, SSTGate Valve, 11/4—11.5 NPT, CSBall Valve, 11/4—11.5 NPT, CS
Code Mounting Hardware
MH5C0MH5S0
Weld Coupling and Nipple, 11/4—11.5 NPT, CSWeld Coupling and Nipple, 11/4—11.5 NPT, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, Parallel
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
MODEL DHT+25S
72
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: DHT+25S 040 HAMS0 C0000 GV5S0 IHRS VT5SG MH5C0
MODEL DHT+25S
Flow-473
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
MODEL DHT+35SModel Product Description
DHT+35S Diamond II + Annubar® Primary Flow Element- Threaded Flo-Tap, High Pressure
Code Line Size
080100120140160180200240300360420480600720
8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HADS0HADSBHADSNHAPS0HAMS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST
HATSBHATSDHATSNHATS0
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, with 3-Valve Manifold, RTD, Horizontal Line, SST
HVDS0HVDSBHVDSNHVPS0HVMS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST
HVTSBHVTSDHVTSNHVTS0
Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, with 3-Valve Manifold, RTD, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valves - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
74
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Instrument Connections (Continued)
CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS
Needle Valves - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
CB2C0CC2C0SB2C0SC2C0SV2C0
Gate Valves - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS
Gate Valves - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
Code Packing Gland
GV8S0GV8C0GH8S0GH8C0
Graphite, 2—11.5 NPT, SSTGraphite, 2—11.5 NPT, CSUrethane, 2—11.5 NPT, SSTUrethane, 2—11.5 NPT, CS
Code Insert/Retract
IHRSIHRCIHDS
Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST Rods
Code Isolation Valves
VT8SGVT8SBVT8CGVT8CB
Gate Valve, 2—11.5 NPT, SSTBall Valve, 2—11.5 NPT, SSTGate Valve, 2—11.5 NPT, CSBall Valve, 2—11.5 NPT, CS
Code Mounting Hardware
MH8C0MH8S0
Weld Coupling and Nipple, 2—11.5 NPT, CSWeld Coupling and Nipple, 2—11.5 NPT, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRRTXRTRATRPTXATXP
Remote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-ProofIntegral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, Parallel
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
MODEL DHT+35S
Flow-475
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number: DHT+35S 120 HAMS0 C0000 GV8S0 IHDS VT8SG MH8C0
MODEL DHT+35S
76
Diam
ond
II+An
nuba
r®
Rosemount Inc.
Flow-477
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
78
Diam
ond
II+An
nuba
r®
Rosemount Inc.
Flow-479
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
80
Diam
ond
II+An
nuba
r®
Rosemount Inc.
Flow-481
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Ordering Information—Model DHFMODEL DHF+15S
Model Product Description
DHF+15S Diamond II Annubar® Primary Flow Element - Flanged Flo-Tap
Code Line Size
020025030035040050
2 in. (50 mm)21/2 in. (63.5 mm)3 in. (80 mm)31/2 in. (89 mm)4 in. (100 mm)5 in. (125 mm)
Code Head Style
HADS0HADSBHADSNHAPS0HAMS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST
HVDS0HVDSBHVDSNHVPS0HVMS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SST
Parallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valve - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS
Needle Valve - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
CB2C0CC2C0SB2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
82
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Instrument Connections (Continued)
CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
Code Packing Gland
GV4SCGV4SBGV4SAGH4SCGH4SBGH4SA
Graphite, 1 in. ANSI Class 600, SSTGraphite, 1 in. ANSI Class 300, SSTGraphite, 1 in. ANSI Class 150, SSTUrethane, 1 in. ANSI Class 600, SSTUrethane, 1 in. ANSI Class 300, SSTUrethane, 1 in. ANSI Class 150, SST
Code Insert/Retract
IHRSIHRC
Manual, Dual, SST RodsManual, Dual, CS Rods
Code Isolation Valves
VC4CGVB4CGVA4CG
Gate Valve - CSGate Valve, 1 in. ANSI Class 600, CSGate Valve, 1 in. ANSI Class 300, CSGate Valve, 1 in. ANSI Class 150, CS
VC4SGVB4SGVA4SG
Gate Valve - SSTGate Valve, 1 in. ANSI Class 600, SSTGate Valve, 1 in. ANSI Class 300, SSTGate Valve, 1 in. ANSI Class 150, SST
VB4CBVA4CB
Ball Valve - CSBall Valve, 1 in. ANSI Class 300, CSBall Valve, 1 in. ANSI Class 150, CS
VB4SBVA4SB
Ball Valve - SSTBall Valve, 1 in. ANSI Class 300, SSTBall Valve, 1 in. ANSI Class 150, SST
Code Flanged Mount
FJMCFJMSFLMCFLMSFNMCFNMSFA4CFA4SFB4CFB4SFC4CFC4S
DIN 25 PN 16, CSDIN 25 PN 16, 316SSTDIN 25 PN 40, CSDIN 25 PN 40, 316SSTDIN 25 PN 100, CSDIN 25 PN 100, 316SST1 in. ANSI Class 150, Weld-Neck RF, CS1 in. ANSI Class 150, Weld-Neck RF, SST1 in. ANSI Class 300, Weld-Neck RF, CS1 in. ANSI Class 300, Weld-Neck RF, SST1 in. ANSI Class 600, Weld-Neck RF, CS1 in. ANSI Class 600, Weld-Neck RF, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRATRPTXATXPTRRTXR
Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
MZ
Lab Flow Calibration (Average K) (<10 in.)Special Calibration
MODEL DHF+15S
Flow-483
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Optional Quality Assurance
QA1Q21Q23Q29QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91ASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DHF+15S 020 HAMS0 C0000 GV4SA IHRS VA4SG FA4C
MODEL DHF+15S
84
Rosemount Inc.
Diam
ond
II+An
nuba
r®
MODEL DHF+25SModel Product Description
DHF+25S Diamond II + Annubar® Primary Flow Element - Flanged Flo-Tap
Code Line Size
040050060080100120140160180200240300360420
4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)
Code Head Style
HADS0HADSBHADSNHAPS0HAMS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, with 3-Valve Manifold, Horizontal Line, SST
HATSBHATSDHATSNHATS0
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, with 3-Valve Manifold, RTD, Horizontal Line, SST
HVDS0HVDSBHVDSNHVPS0HVMS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, with 3-Valve Manifold, Vertical Line, SST
HVTSBHVTSDHVTSNHVTS0
Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, with 3-Valve Manifold, RTD, Vertical Line, SST
HA2S0HA2SSHAHS0HAHSSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTAxial, HP, Horizontal Line, 1/2—14 NPT, SSTAxial, HP, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line,1/2 in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SSHVHS0HVHSS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SSTAxial, HP, Vertical Line, 1/2—14 NPT, SSTAxial, HP, Vertical Line, 1/2 in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valve - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
Flow-485
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Instrument Connections (Continued)
CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS
Needle Valve - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
CB2C0CC2C0SB2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
Code Packing Gland
GV6SCGV6SBGV6SAGH6SCGH6SBGH6SA
Graphite, 11/2 in. ANSI Class 600, SSTGraphite, 11/2 in. ANSI Class 300, SSTGraphite, 11/2 in. ANSI Class 150, SSTUrethane, 11/2 in. ANSI Class 600, SSTUrethane, 11/2 in. ANSI Class 300, SSTUrethane, 11/2 in. ANSI Class 150, SST
Code Insert/Retract
IHRSIHRCIHDSIHDC
Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods
Code Isolation Valves
VC6CGVB6CGVA6CG
Gate Valve - CSGate Valve, 11/2 in. ANSI Class 600, CSGate Valve, 11/2 in. ANSI Class 300, CSGate Valve, 11/2 in. ANSI Class 150, CS
VC6SGVB6SGVA6SG
Gate Valve - SSTGate Valve, 11/2 in. ANSI Class 600, SSTGate Valve, 11/2 in. ANSI Class 300, SSTGate Valve, 11/2 in. ANSI Class 150, SST
VB6CBVA6SB
Ball Valve - CSBall Valve, 11/2 in. ANSI Class 300, CSBall Valve, 11/2 in. ANSI Class 150, SST
VB6SBVA6SB
Ball Valve - SSTBall Valve, 11/2 in. ANSI Class 300, SSTBall Valve, 11/2 in. ANSI Class 150, SST
Code Flanged Mount
FA6CFA6SFB6CFB6SFC6CFC6SFE8CFE8S
11/2 in. ANSI Class 150, Weld-Neck RF, CS11/2 in. ANSI Class 150, Weld-Neck RF, SST11/2 in. ANSI Class 300, Weld-Neck RF, CS11/2 in. ANSI Class 300, Weld-Neck RF, SST11/2 in. ANSI Class 600, Weld-Neck RF, CS11/2 in. ANSI Class 600, Weld-Neck RF, SST2 in. ANSI Class 900/1500, Weld-Neck RF, CS2 in. ANSI Class 1500, Weld-Neck RF, SST
MODEL DHF+25S
86
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRATRPTXATXPTRRTXR
Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DHF+25S 040 HAMS0 C0000 GV4SA IHRC VA6CG FA6C
MODEL DHF+25S
Flow-487
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
MODEL DHF+25HModel Product Description
DHF+25H Diamond II + Annubar® Primary Flow Element - Flanged Flo-Tap
Code Line Size
040050060080100120140160180200240300360420
4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)
Code Head Style
HADH0HADHBHADHNHAPH0HAMH0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-CDirect Mount, No Manifold, Horizontal Line, Hastelloy-CIntegral, with 3-Valve Manifold, Horizontal Line, Hastelloy-C
HATHDHATHNHATHBHATH0
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, Hastelloy-CIntegral, with 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-C
HVDH0HVDHBHVDHNHVPH0HVMH0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, Hastelloy-CDirect Mount, No Manifold, Vertical Line, Hastelloy-CIntegral, with 3-Valve Manifold, Vertical Line, Hastelloy-C
HVTHBHVTHDHVTHNHVTH0
Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-CIntegral, with 3-Valve Manifold, RTD, Vertical Line, Hastelloy-C
HA2H0HA2HSHAHH0
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, Hastelloy-CAxial, Horizontal Line, 1/2 in. Socket Weld Ports, Hastelloy-CAxial, HP, Horizontal Line, 1/2—14 NPT, Hastelloy-C
HAHHSHP2H0
Remote Mount - Horizontal LineAxial, HP, Horizontal Line, 1/2 in. Socket Weld Ports, Hastelloy-CParallel, Horizontal Line, 1/2—14 NPT, Hastelloy-C
HPVH0HV2H0HVHH0HVHHS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2—14 NPT, Hastelloy-CAxial, Vertical Line, 1/2—14 NPT, Hastelloy-CAxial, HP, Vertical Line, 1/2—14 NPT, Hastelloy-CAxial, HP, Vertical Line, 1/2 in. Socket Weld Ports, Hastelloy-C
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valve - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2S0CP2S0SA2S0SP2S0
Needle Valve - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SST
88
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Instrument Connections (Continued)
CB2C0CC2C0SB2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2S0CC2S0SB2S0SC2S0SV2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
CA2H0CP2H0
Needle Valve - Hastelloy-CNeedle Valve, Elbow, 1/2—14 NPT, Hastelloy-CNeedle Valve, Nipple, 1/2—14 NPT, Hastelloy-C
Code Packing Glands
GV6HCGV6HBGV6HA
Graphite, 11/2 in. ANSI Class 600, Hastelloy-CGraphite, 11/2 in. ANSI Class 300, Hastelloy-CGraphite, 11/2 in. ANSI Class 150, Hastelloy-C
Code Insert/Retract
IHRSIHRCIHDSIHDC
Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods
Code Isolation Valves
VC6CGVB6CGVA6CG
Gate Valve - CSGate Valve, 11/2 in. ANSI Class 600, CSGate Valve, 11/2 in. ANSI Class 300, CSGate Valve, 11/2 in. ANSI Class 150, CS
VC6SGVB6SGVA6SG
Gate Valve - SSTGate Valve, 11/2 in. ANSI Class 600, SSTGate Valve, 11/2 in. ANSI Class 300, SSTGate Valve, 11/2 in. ANSI Class 150, SST
VB6CBVA6CB
Ball Valve - CSBall Valve, 11/2 in. ANSI Class 300, CSBall Valve, 11/2 in. ANSI Class 150, CS
VB6SBVA6SB
Ball Valve - SSTBall Valve, 11/2 in. ANSI Class 300, SSTBall Valve, 11/2 in. ANSI Class 150, SST
Code Flanged Mount
FA6CFA6SFB6CFB6SFC6CFC6SFE8CFE8S
11/2 in. ANSI Class 150, Weld-Neck RF, CS11/2 in. ANSI Class 150, Weld-Neck RF, SST1 1/2 in. ANSI Class 300, Weld-Neck RF, CS11/2 in. ANSI Class 300, Weld-Neck RF, SST11/2 in. ANSI Class 600, Weld-Neck RF, CS11/2 in. ANSI Class 600, Weld-Neck RF, SST2 in. ANSI Class 900/1500, Weld-Neck RF, CS2 in. ANSI Class 1500, Weld-Neck RF, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRATRPTXATXPTRRTXR
Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
MODEL DHF+25H
Flow-489
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DHF+25H 040 HAMH0 C0000 GV6HA IHRS VA6SG FA6C
MODEL DHF+25H
90
Rosemount Inc.
Diam
ond
II+An
nuba
r®
MODEL DHF + 25MModel Product Description
DHF+25M Diamond II + Annubar® Primary Flow Element - Flanged Flo-Tap
Code Line Size
040050060080100120140160180200240300360420
4 in. (100 mm)5 in. (125 mm)6 in. (150 mm)8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)
Code Head Style
HADM0HADMBHADMNHAPM0HAMM0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, MonelDirect Mount, No Manifold, Horizontal Line, MonelIntegral, with 3-Valve Manifold, Horizontal Line, Monel
HATMDHATMNHATMBHATM0
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, MonelIntegral, with 3-Valve Manifold, RTD, Horizontal Line, Monel
HVDM0HVDMBHVDMNHVPM0HVMM0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, B31.1, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, NACE, Vertical Line, MonelDirect Mount, No Manifold, Vertical Line, MonelIntegral, with 3-Valve Manifold, Vertical Line, Monel
HVTMBHVTMDHVTMNHVTM0
Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, MonelIntegral, with 3-Valve Manifold, RTD, Vertical Line, Monel
HA2M0HA2MSHAHM0HAHMSHP2M0
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, MonelAxial, Horizontal Line, 1/2 in. Socket Weld Ports, MonelAxial, HP, Horizontal Line, 1/2—14 NPT, MonelAxial, HP, Horizontal Line, 1/2 in. Socket Weld Ports, MonelParallel, Horizontal Line, 1/2—14 NPT, Monel
HPVM0HV2M0HV2MSHVHM0HVHMS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2—14 NPT, MonelAxial, Vertical Line, 1/2—14 NPT, MonelAxial, Vertical Line, 1/2 in. Socket Weld Ports, MonelAxial, HP, Vertical Line, 1/2—14 NPT, MonelAxial, HP, Vertical Line, 1/2 in. Socket Weld Ports, Monel
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valve - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
Flow-491
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Instrument Connections (Continued)
CA2S0CP2S0SA2S0SP2S0
Needle Valve - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SST
CA2M0CP2M0
Needle Valve - MonelNeedle Valve, Elbow, 1/2—14 NPT, MonelNeedle Valve, Nipple, 1/2—14 NPT, Monel
CB2C0CC2C0SB2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2S0CC2S0SB2S0SC2S0SV2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
Code Packing Glands
GV6MCGV6MBGV6MA
Graphite, 11/2 in. ANSI Class 600, MonelGraphite, 11/2 in. ANSI Class 300, MonelGraphite, 11/2 in. ANSI Class 150, Monel
Code Insert/Retract
IHRSIHRCIHDSIHDC
Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods
Code Isolation Valves
VC6CGVB6CGVA6CG
Gate Valve - CSGate Valve, 11/2 in. ANSI Class 600, CSGate Valve, 11/2 in. ANSI Class 300, CSGate Valve, 1 in. ANSI Class 150, CS
VC6SGVB6SGVA6SG
Gate Valve - SSTGate Valve, 11/2 in. ANSI Class 600, SSTGate Valve, 11/2 in. ANSI Class 300, SSTGate Valve, 11/2 in. ANSI Class 150, SST
VB6CBVA6CB
Ball Valve - CSBall Valve, 11/2 in. ANSI Class 300, CSBall Valve, 11/2 in. ANSI Class 150, CS
VB6SBVA6SB
Ball Valve - SSTBall Valve, 11/2 in. ANSI Class 300, SSTBall Valve, 11/2 in. ANSI Class 150, SST
Code Flanged Mount
FA6CFA6SFB6CFB6SFC6CFC6SFE8CFE8S
11/2 in. ANSI Class 150, Weld-Neck RF, CS11/2 in. ANSI Class 150, Weld-Neck RF, SST11/2 in. ANSI Class 300, Weld-Neck RF, CS11/2 in. ANSI Class 300, Weld-Neck RF, SST11/2 in. ANSI Class 600, Weld-Neck RF, CS11/2 in. ANSI Class 600, Weld-Neck RF, SST2 in. ANSI Class 900/1500, Weld-Neck RF, CS2 in. ANSI Class 1500, Weld-Neck RF, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRATRPTXATXPTRRTXR
Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
MODEL DHF + 25M
92
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DHF+25M 040 HAMM0 C0000 GV6MA IHRS VA6SG FA6C
MODEL DHF + 25M
Flow-493
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
MODEL DHF+35SModel Product Description
DHF+35S Diamond II + Annubar® Primary Flow Element - Flanged Flo-Tap
Code Line Size
080100120140160180200240300360420480600720
8 in. (200 mm)10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HADS0HADSBHADSNHAPS0HAMS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, 3-Valve Manifold, Horizontal Line, SST
HATSBHATSDHATSNHATS0
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, RTD, Horizontal Line, SST
HVDS0HVDSBHVDSNHVPS0HVMS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SST
HVTSBHVTSDHVTSNHVTS0
Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, 3-Valve Manifold, RTD, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SST
Parallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valves - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
94
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Instrument Connections (Continued)
CA2S0CA2SSCP2S0CP2SSSA2S0SP2S0SP2SS
Needle Valve - SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
CB2C0CC2C0SB2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2S0CB2SSCC2S0CC2SSSB2S0SC2S0SV2S0SV2SS
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in., Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
Code Packing Glands
GV8SCGV8SBGV8SAGH8SCGH8SBGH8SA
Graphite, 2 in. ANSI Class 600, SSTGraphite, 2 in. ANSI Class 300, SSTGraphite, 2 in. ANSI Class 150, SSTUrethane, 2 in. ANSI Class 600, SSTUrethane, 2 in. ANSI Class 300, SSTUrethane, 2 in. ANSI Class 150, SST
Code Insert/Retract
IHRSIHRCIHDSIHDC
Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods
Code Isolation Valve
VB8CGVA8CG
Gate Valve - CSGate Valve, 2 in. ANSI Class 300, CSGate Valve, 2 in. ANSI Class 150, CS
VB8SGVA8SG
Gate Valve - SSTGate Valve, 2 in. ANSI Class 300, SSTGate Valve, 2 in. ANSI Class 150, SST
VB8CBVA8CB
Ball Valve - CSBall Valve, 2 in. ANSI Class 300, CSBall Valve, 2 in. ANSI Class 150, CS
VB8SBVA8SB
Ball Valve - SSTBall Valve, 2 in. ANSI Class 300, SSTBall Valve, 2 in. ANSI Class 150, SST
Code Flanged Mount
FA8CFA8SFB8CFB8SFC8CFC8S
2 in. ANSI Class 150, Weld-Neck RF, CS2 in. ANSI Class 150, Weld-Neck RF, SST2 in. ANSI Class 300, Weld-Neck RF, CS2 in. ANSI Class 300, Weld-Neck RF, SST2 in. ANSI Class 600, Weld-Neck RF, CS2 in. ANSI Class 600, Weld-Neck RF, SST
MODEL DHF+35S
Flow-495
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRATRPTXATXPTRRTXR
Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DHF+35S 120 HAMS0 C0000 GV8SA IHDS VA8SG FA8C
MODEL DHF+35S
96
Rosemount Inc.
Diam
ond
II+An
nuba
r®
MODEL DHF+45SModel Product Description
DHF+45S Diamond II + Annubar® Primary Flow Element - Flanged Flo-Tap
Code Line Size
100120140160180200240300360420480600720
10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HADS0HADSBHADSNHAPS0HAMS0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, SSTDirect Mount, No Manifold, Horizontal Line, SSTIntegral, 3-Valve Manifold, Horizontal Line, SST
HATSBHATSDHATSNHATS0
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SSTIntegral, 3-Valve Manifold, RTD, Horizontal Line, SST
HVDS0HVDSBHVDSNHVPS0HVMS0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, SSTDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, SSTDirect Mount, 5-Valve Manifold, NACE, Vertical Line, SSTDirect Mount, No Manifold, Vertical Line, SSTIntegral, 3-Valve Manifold, Vertical Line, SST
HVTSBHVTSDHVTSNHVTS0
Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, SSTDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, SSTDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SSTIntegral, 3-Valve Manifold, RTD, Vertical Line, SST
HA2S0HA2SSHP2S0HP2SS
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, SSTAxial, Horizontal Line, 1/2 in. Socket Weld Ports, SSTParallel, Horizontal Line, 1/2—14 NPT, SSTParallel, Horizontal Line, 1/2 in. Socket Weld Ports, SST
HPVS0HPVSSHV2S0HV2SS
Remote Mount - Vertical LineParallel, Vertical Line, 1/2 in. Socket Weld Ports, SSTParallel, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2—14 NPT, SSTAxial, Vertical Line, 1/2 in. Socket Weld Ports, SST
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CA2C0CP2C0SA2C0SP2C0
Needle Valves - CSNeedle Valve, Elbow, 1/2—14 NPT, CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Elbow and Tee, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
Flow-497
Flow-4
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Instrument Connections (Continued)
CA2SSCA2S0CP2S0SA2S0SP2S0CP2SSSP2SS
Needle Valve - SSTNeedle Valve, Elbow, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Elbow, 1/2—14 NPT, SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Elbow and Tee, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SSTNeedle valve, Nipple, 1/2 in. Socket Weld Ports, SSTNeedle Valve, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
CB2C0CC2C0SB2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2S0CC2S0SB2S0SC2S0SV2S0CB2SSCC2SSSV2SS
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Ports, SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2 in.,Socket Weld Port, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Ports, SST
Code Packing Glands
GVDHCGVDHBGVDHA
Graphite, 3 in. ANSI Class 600, Hastelloy-CGraphite, 3 in. ANSI Class 300, Hastelloy-CGraphite, 3 in. ANSI Class 150, Hastelloy-C
Code Insert/Retract
IHRSIHRCIHDSIHDC
Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods
Code Isolation Valve
VCDCGVBDCGVADCG
Gate Valve - CSGate Valve, 3 in. ANSI Class 600, CSGate Valve, 3 in. ANSI Class 300, CSGate Valve, 3 in. ANSI Class 150, CS
VCDSGVBDSGVADSG
Gate Valve - SSTGate Valve, 3 in. ANSI Class 600, SSTGate Valve, 3 in. ANSI Class 300, SSTGate Valve, 3 in. ANSI Class 150, SST
VBDCBVADCB
Ball Valve - CSBall Valve, 3 in. ANSI Class 300, CSBall Valve, 3 in. ANSI Class 150, CS
VBDSBVADSB
Ball Valve - SSTBall Valve, 3 in. ANSI Class 300, SSTBall Valve, 3 in. ANSI Class 150, SST
Code Flanged Mount
FADCFADSFBDCFBDSFCDCFCDS
3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600, Weld-Neck RF, CS3 in. ANSI Class 600, Weld-Neck RF, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRATRPTXATXPTRRTXR
Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
MODEL DHF+45S
98
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DHF+45S 240 HAMS0 C0000 GVDHA IHDS VADSG FADC
MODEL DHF+45S
Flow-499
Flow-5
Diamond II+ Annubar®
Diamond
II+Annubar®
MODEL DHF+45HModel Product Description
DHF+45H Diamond II + Annubar® Primary Flow Element - Flanged Flo-Tap
Code Line Size
100120140160180200240300360420480600720
10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. 1520 mm)72 in. (1820 mm)
Code Head Style
HADH0HADHBHADHNHAPH0HAMH0
Direct and Integral Mount Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, B31.1,Horizontal Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-CDirect Mount, No Manifold, Horizontal Line, Hastelloy-CIntegral, 3-Valve Manifold, Horizontal Line, Hastelloy-C
HATHDHATHNHATHBHATH0
Direct and Integral Mount Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, Hastelloy-CIntegral, 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-C
HVDH0HVDHBHVDHNHVPH0HVMH0
Direct and Integral Mount Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, NACE, Vertical Line, Hastelloy-CDirect Mount, No Manifold, Vertical Line, Hastelloy-CIntegral, 3-Valve Manifold, Vertical Line, Hastelloy-C
HVTHBHVTHDHVTHNHVTH0
Direct and Integral Mount Heads - Vertical Line with RTDDirect Mount, 5-Valve Manifold, TD, B31.1, Vertical Line, Hastelloy-CDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, Hastelloy-CDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-CIntegral, 3-Valve Manifold, RTD, Vertical Line, Hastelloy-C
HA2H0HA2HSHP2H0
Remote Mount - Horizontal LineAxial, Horizontal Line, 1/2—14 NPT, Hastelloy-CAxial, Horizontal Line, 1/2 in. Socket Weld Ports, Hastelloy-CParallel, Horizontal Line, 1/2—14 NPT, Hastelloy-C
HPVH0HV2H0
Remote Mount - Vertical LineParallel, Vertical Line, 1/2—14 NPT, Hastelloy-CAxial, Vertical Line, 1/2—14 NPT, Hastelloy-C
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0
Needle Valves - CSNeedle Valve, Nipple, 1/2—14 NPT, CSNeedle Valve, Nipple and Tee, 1/2—14 NPT, CS
CP2S0SP2S0
Needle Valves - SSTNeedle Valve, Nipple, 1/2—14 NPT, SSTNeedle Valve, Nipple and Tee, 1/2—14 NPT, SST
CP2H0Needle Valves - Hastelloy-CNeedle Valve, Nipple, 1/2—14 NPT, Hastelloy-C
CC2C0SC2C0SV2C0
Gate Valves - CSOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
00
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Code Instrument Connections (Continued)
CC2S0SC2S0SV2S0
Gate Valves - SSTOutside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
Code Packing Glands
GVDHCGVDHBGVDHA
Graphite, 3 in. ANSI Class 600, Hastelloy-CGraphite, 3 in. ANSI Class 300, Hastelloy-CGraphite, 3 in. ANSI Class 150, Hastelloy-C
Code Insert/Retract
IHRSIHRCIHDSIHDC
Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods
Code Isolation Valve
VCDCGVBDCGVADCG
Gate Valve - CSGate Valve, 3 in. ANSI Class 600, CSGate Valve, 3 in. ANSI Class 300, CSGate Valve, 3 in. ANSI Class 150, CS
VCDSGVBDSGVADSG
Gate Valve - SSTGate Valve, 3 in. ANSI Class 600, SSTGate Valve, 3 in. ANSI Class 300, SSTGate Valve, 3 in. ANSI Class 150, SST
VBDCBVADCB
Ball Valve - CSBall Valve, 3 in. ANSI Class 300, CSBall Valve, 3 in. ANSI Class 150, CS
VBDSBVADSB
Ball Valve - SSTBall Valve, 3 in. ANSI Class 300, SSTBall Valve, 3 in. ANSI Class 150, SST
Code Flanged Mount
FADCFADSFBDCFBDSFCDCFCDS
3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600, Weld-Neck RF, CS3 in. ANSI Class 600, Weld-Neck RF, SST
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRATRPTXATXPTRRTXR
Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 to 16 in.)Lab Flow Calibration (Average K) (18 to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
MODEL DHF+45H
Flow-501
Flow-5
Diamond II+ Annubar®
Diamond
II+Annubar®
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DHF+45H 240 HAMH0 C0000 GVDHA IHDS VADSG FADC
MODEL DHF+45H
02
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Model DHF+45MModel Product Description
DHF+45M Diamond II + Annubar® Primary Flow Element - Flanged Flo-Tap
Code Line Size
100120140160180200240300360420480600720
10 in. (250 mm)12 in. (300 mm)14 in. (350 mm)16 in. (400 mm)18 in. (450 mm)20 in. (500 mm)24 in. (600 mm)30 in. (750 mm)36 in. (900 mm)42 in. (1066 mm)48 in. (1210 mm)60 in. (1520 mm)72 in. (1820 mm)
Code Head Style
HADM0HADMBHADMNHAPM0HAMM0
Direct and Integral Mounted Heads - Horizontal LineDirect Mount, with 5-Valve Manifold, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, B31.1, Horizontal Line, MonelDirect Mount, with 5-Valve Manifold, NACE, Horizontal Line, MonelDirect Mount, No Manifold, Horizontal Line, MonelIntegral, 3-Valve Manifold, Horizontal Line, Monel
HATMDHATMNHATMBHATM0
Direct and Integral Mounted Heads - Horizontal Line with RTDDirect Mount, with 5-Valve Manifold, RTD, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, MonelDirect Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, MonelIntegral, 3-Valve Manifold, RTD, Horizontal Line, Monel
HVDM0HVDMBHVDMNHVPM0HVTM0
Direct and Integral Mounted Heads - Vertical LineDirect Mount, with 5-Valve Manifold, Vertical Line, MonelDirect Mount, 5-Valve Manifold, B31.1, Vertical Line, MonelDirect Mount, 5-Valve Manifold, NACE, Vertical Line, MonelDirect Mount, No Manifold, Vertical Line, MonelIntegral, 3-Valve Manifold, RTD, Vertical Line, Monel
HVTMBHVTMDHVTMNHVMM0
Direct and Integral Mounted Heads - Vertical Line with RTDDirect Mount, 5-Valve Manifold, TD, B31.1, Vertical Line, MonelDirect Mount, with 5-Valve Manifold, RTD, Vertical Line, MonelDirect Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, MonelIntegral, 3-Valve Manifold, RTD, Vertical Line, Monel
HA2M0HA2MSHP2M0
Remote Mount - Horizontal LineAxial, Horizontal Line, ½—14 NPT, MonelAxial, Horizontal Line, ½ in. Socket Weld Ports, MonelParallel, Horizontal Line, ½—14 NPT, Monel
HPVM0HV2M0HV2MS
Remote Mount - Vertical LineParallel, Vertical Line, ½—14 NPT, MonelAxial, Vertical Line, ½—14 NPT, MonelAxial, Vertical Line, ½ in. Socket Weld Ports, Monel
Code Instrument Connections
C0000S0000
Eliminate Instrument Connection Assembly (For Use with Direct and Integral Mount Head Styles)Eliminate Instrument Connection AssemblyEliminate Instrument Connection Assembly (Steam)
CP2C0SP2C0
Needle Valves - CSNeedle Valve, Nipple, ½—14 NPT, CSNeedle Valve, Nipple and Tee, ½—14 NPT, CS
CP2S0SP2S0
Needle Valve - SSTNeedle Valve, Nipple, ½—14 NPT, SSTNeedle Valve, Nipple and Tee, ½—14 NPT, SST
CP2M0Needle Valve - MonelNeedle Valve, Nipple, ½—14 NPT, Monel
CC2C0SC2C0SV2C0
Gate Valve - CSOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Nipple and Tee, ½—14 NPT, CSOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS
CC2S0SC2S0SV2S0
Gate Valve - SSTOutside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Nipple and Tee, Steam, ½—14 NPT, SSTOutside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SST
Flow-503
Diamond II+ Annubar®
Flow-5
Diamond
II+Annubar®
Code Packing Glands
GVDMCGVDMBGVDMA
Graphite, 3 in. ANSI Class 600, MonelGraphite, 3 in. ANSI Class 300, MonelGraphite, 3 in. ANSI Class 150, Monel
Code Insert/Retract
IHRSIHRCIHDSIHDC
Manual, Dual, SST RodsManual, Dual, CS RodsGear, Dual, SST RodsGear, Dual, CS Rods
Code Isolation Valve
VCDCGVBDCGVADCG
Gate Valve - CSGate Valve, 3 in. ANSI Class 600, CSGate Valve, 3 in. ANSI Class 300, CSGate Valve, 3 in. ANSI Class 150, CS
VCDSGVBDSGVADSG
Gate Valve - SSTGate Valve, 3 in. ANSI Class 600, SSTGate Valve, 3 in. ANSI Class 300, SSTGate Valve, 3 in. ANSI Class 150, SST
VBDCBVADCB
Ball Valve - CSBall Valve, 3 in. ANSI Class 300, CSBall Valve, 3 in. ANSI Class 150, CS
VBDSBVADSB
Ball Valve - SSTBall Valve, 3 in. ANSI Class 300, SSTBall Valve, 3 in. ANSI Class 150, SST
Code Flanged Mount
FADCFADSFBDCFBDSFCDCFCDS
3 in. ANSI Class 150, Weld-Neck RF, CS3 in. ANSI Class 150, Weld-Neck RF, SST3 in. ANSI Class 300, Weld-Neck RF, CS3 in. ANSI Class 300, Weld-Neck RF, SST3 in. ANSI Class 600, Weld-Neck RF, CS3 in. ANSI Class 600, Weld-Neck RF, SST
Code Optional Temperature Sensors (For Use with Remote Mount Head Styles)
TRATRPTXATXPTRRTXR
Integral RTD, Axial HeadIntegral RTD, Parallel HeadIntegral RTD, FM Explosion-Proof, AxialIntegral RTD, FM Explosion-Proof, ParallelRemote Thermowell and RTDRemote Thermowell and RTD, FM Explosion-Proof
Code Optional Special Assembly
S4 Factory Assembly of DP Transmitter to DP primary
Code Optional Calibration
MZOQSUWY
Lab Flow Calibration (Average K) (<10 in.)Special CalibrationLab Flow Calibration (Average K) (12 in.)Lab Flow Calibration (Average K) (14 in. to 16 in.)Lab Flow Calibration (Average K) (18 in. to 20 in.)Lab Flow Calibration (Average K) (24 in.)Lab Flow Calibration (Average K) (30 in.)Lab Flow Calibration (Average K) (36 in.)
Code Optional Quality Assurance
QA1Q21Q23Q29QJ2QM2QT1QT2QT8
Dieterich ProgramANSI B31.1ANSI B31.3NACE MR-0175-91Special Product DrawingASTM Material-Traceable (Sensor Only)Hydrostatic Test EP-4017Dye Penetrant ES-1012Extended Hydro EP-4046
Typical Model Number DHF+45M 240 HAMM0 C0000 GVDMA IHDS VADSG FADC
Model DHF+45M
04
Diam
ond
II+An
nuba
r®
Rosemount Inc.
Flow-505
Flow-5
Diamond II+ Annubar®
Diamond
II+Annubar®
06
Diam
ond
II+An
nuba
r®
Rosemount Inc.
Flow-507
Flow-5
Diamond II+ Annubar®
Diamond
II+Annubar®
08
Rosemount Inc.
Diam
ond
II+An
nuba
r®
Specifications
FUNCTIONAL SPECIFICATIONS
Service
Liquid, gas, and steam applications.
Pipe Sizes
½ in. to 72 in. (12 mm to 1820 mm).
Flow Sensor Sizes (SST)
TABLE 3. Flow Sensor Sizes (SST).
Flow Sensor Sizes(Hastelloy-C and Monel)
TABLE 4. Flow Sensor Sizes (Hastelloy—C and Monel).
Operating Process Temperature LimitsIntegral head style: -40 °F to 500 °F (-40 °C to 454 °C).
For HATSB, HVTSB, HADSB, and HVDSB head styles and regular flanged, Flo-Tap models: -40 °F to 750 °F (-40 °C to 398 °C).
Remote mount (SST and Monel):-40 °F to 850 °F (-40 °C to 454 °C).
Remote mount (Hastelloy-C):-40 °F to 900 °F (-40 °C to 482 °C).
Remote mount (Hastelloy-C) with remote temperature sensor :-40 °F to 1200 °F (-40 °C to 649 °C).
Pressure Limits
0–1440 psig (100 barg) @ 100 °F (37.8 °C).
Contact the factory for higher pressures.
PERFORMANCE SPECIFICATIONS
Accuracy
±1% of flow coefficient.
When used in closed loop–control applications, higher damping values are recommended.
Repeatability
±0.1%.
TABLE 5. Model Minimum Reynold’s Numbers.
See the Annubar Primary Flow Element Handbook for detailed information (page Flow-375).
May be protected by one or more of the following U.S. Patent Nos.4,559,836; 4,717,159;5,710,370; 5,773,726; 4,633, 713; and various foreign patents. Other foreign patents issuedand pending.
Rosemount, the Rosemount logotype, PlantWeb, Fisher-Rosemount, and Managing theProcess Better are marks of one of the Fisher-Rosemount group of companies. Coplanar,MV, and Multivariable are trademarks of Rosemount Inc.
Mass ProBar, ProBar, and Annubar are registered trademarks of Dieterich Standard Inc.
HART is a registered trademark of the HART Communications Foundation.
Monel is a registered trademark of International Nickel Co.
Teflon is a registered trademark of E. I. du Pont de Nemours & Co.
Hastelloy C and Hastelloy C-276 are registered trademarks of Cabot Corp.
Windows is a trademark of Microsoft Corp.
All other marks are the property of their respective owners.
Sensor # For Line Sizes
10 ½ in. to 2 in. (12.5 mm to 50 mm)
15/16 2 in. to 5 in. (50 mm to 125 mm)
25/26 4 in. to 42in. (100 mm to 1066 mm)
35/36 8 in. to 72 in. (200 mm to 1820 mm)
45/46 10 in. to 72 in. (250 mm to 1820 mm)
Sensor # For Line Sizes
10 ½ in. to 2 in. (12.5 mm to 50 mm)
25/26 4 in. to 42 in. (100 mm to 1066 mm)
45/46 10 in. to 72 in. (250 mm to 1820 mm)
Model Minimum Reynold’s Number (Re rod )
10 2300
½ in. lines 4000
15/16 6500
25/26 10000
35/36 15000
45/46 25000
Where: ρ = fluid density in lbm/ft3
d = probe width in feetV = velocity of fluid in ft/secµ = fluid viscosity in lbm/ft–sec
Rerod = dVρ
µ
Flow-509
Flow-5
Diamond II+ Annubar®
Diamond
II+Annubar®
PHYSICAL SPECIFICATIONS
Sensor
316/316L SST.
Hastelloy—C (flanged models, sensors 10, 25/26, and 45/46).
Monel (flanged models, sensors 10, 25/26, and 45/46).
Integral Valve and Direct Mounts HeadStyles (3 and 5 Valve)
Material
316 SST (Hastelloy—C and Monel options).
O–Rings
Teflon® (Grafoil above 500 °F [260 °C]).
Bolts
316 SST.
Flange, Isolation Valves
316L SST. Flange pressure limits are per ANSI B16.5 for 316 SST and material per SA 182. Flange face finish ANSI B16.5, 125 to 250 RMS.
Packing Gland Assembly
Packing Gland: 316 SST.
Packing: Graphite AFP–127.
Flange Mounting Hardware
(Includes nuts, bolts, and gasket) 316 SST or CS.
Temperature Options
Integral RTD: 100 Ω Platinum RTD.
Remote: 100 Ω Platinum RTD, spring loaded with½ in.—14 NPT nipple and union.
Thermowell: ½ in. × ½ in.—14 NPT, 316 SST with ½ in. CS weld couplet, u = 2½ in.
00813-0100-4760 Rev. DA 11/98
¢00813-0100-4762+¤
PR
INTED
INU.S. A.
Dieterich Standard Inc.5601 North 71st StreetBoulder, CO 80301Tel (303) 530-9600Fax (303) 530-7064
© 1998 Rosemount Inc.http://www.rosemount.com
Fisher-RosemountSingapore Pte Ltd.1 Pandan CrescentSingapore 128461Tel (65) 777-8211Fax (65) 777-0947Tlx RS 61117 FRSPL
Fisher-Rosemount LimitedHeath Place Bognor RegisWest Sussex PO22 9SHEnglandTel 44 (1243) 863 121Fax 44 (1243) 867 5541
Rosemount Inc.8200 Market BoulevardChanhassen, MN 55317 USATel 1-800-999-9307Telex 4310012Fax (612) 949-7001
10