digital scroll technology ec fans - airah · inverter hsp lsp - slim energy efficiency (digital)...

16
1 Digital Scroll Technology & EC Fans EC Fans By : Amro Said – Product Manager Objective ActronAir Profile ESP Series Digital Vertical Package TriCapacity Q&A

Upload: others

Post on 26-Mar-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Digital Scroll Technology EC Fans - AIRAH · Inverter HSP LSP - SLIM Energy Efficiency (Digital) ESP ESP PLUS OPRT Standard Cycling Vertical Package ... FAN POWER CONSUMPTION STANDA

1

Digital Scroll Technology & EC FansEC Fans

By : Amro Said – Product Manager

Objective

ActronAir Profile

ESP Series

Digital Vertical Package

Tri‐Capacity 

Q & A

Page 2: Digital Scroll Technology EC Fans - AIRAH · Inverter HSP LSP - SLIM Energy Efficiency (Digital) ESP ESP PLUS OPRT Standard Cycling Vertical Package ... FAN POWER CONSUMPTION STANDA

2

Page 3: Digital Scroll Technology EC Fans - AIRAH · Inverter HSP LSP - SLIM Energy Efficiency (Digital) ESP ESP PLUS OPRT Standard Cycling Vertical Package ... FAN POWER CONSUMPTION STANDA

3

The largest Air Cooled Product Range in Australia!

Residential Products Commercial Products

Room Air Conditioning

Wall Hung FJM

Ducted Air Conditioning

Standard CyclingInverter

LSP - SLIMHSP

Energy Efficiency (Digital)

ESP ESP PLUS

OPRT

Standard Cycling

Vertical Package

Tri-Capacity Package

Ducted Air Conditioning

Standard Cycling Tri-Capacity

CAC VRF

ESP Ultima

Samsung ActronAir

ESP SeriesESP Series

Page 4: Digital Scroll Technology EC Fans - AIRAH · Inverter HSP LSP - SLIM Energy Efficiency (Digital) ESP ESP PLUS OPRT Standard Cycling Vertical Package ... FAN POWER CONSUMPTION STANDA

4

Energy Smart Performance (ESP Series)

++or

D

NA

IR

AIR3

3.2

cy

EER Vs. Variable Capacity

Com

petit

o

AC

TRO

N

AC

TRO

NA

2.2

2.4

2.6

2.8

Ener

gy E

ffici

enc

2Part Load (70%) Full Load (100%)

Capacity Percentage

Information based on Australian standard test in a AS/NZS 3823.1.2 psychometric lab

Page 5: Digital Scroll Technology EC Fans - AIRAH · Inverter HSP LSP - SLIM Energy Efficiency (Digital) ESP ESP PLUS OPRT Standard Cycling Vertical Package ... FAN POWER CONSUMPTION STANDA

5

90

100

High Ambient Cooling Capacity

50

60

70

80

Capacity %

40

35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52Outdoor Ambient Temperature  

Information based on Australian standard test in a AS/NZS 3823.1.2 psychometric lab

EC Variable Fan

Page 6: Digital Scroll Technology EC Fans - AIRAH · Inverter HSP LSP - SLIM Energy Efficiency (Digital) ESP ESP PLUS OPRT Standard Cycling Vertical Package ... FAN POWER CONSUMPTION STANDA

6

Award winning innovation for ESP Plus

• AIRAH Achievement Awards• CoolWorld Awards

Variable Air Flow technology 

Has the intelligence to actually learn the ducting and zoning system?

Can operate with only one zone on.

Subject to min air flow of 20%

d l S ft St t AStarts and Stops very quietly. 

Variable fanStd fan

Fullcapacity

OffDelay

Pre-run Shortrun

offon

Soft Start Area

Page 7: Digital Scroll Technology EC Fans - AIRAH · Inverter HSP LSP - SLIM Energy Efficiency (Digital) ESP ESP PLUS OPRT Standard Cycling Vertical Package ... FAN POWER CONSUMPTION STANDA

7

ActronAir Variable Fan v Std Fan

Variable Fan Standard Fan

Airflows as per required Duty. Excess Supply air when Zoning.

Superior Energy savings using the EC motor. Induction Motor is less efficient.

Reduced Noise levels on start up and zoning.

Noisy when Zoning and on start up.

UPSTAIRS

1000 L/sREQUIREDAIRFLOW

1 2

Required Air Flow Vs Delivered Air Flow (L/S)

DOWNSTAIRS

750 L/s

500 L/s

STANDARD FAN IS OVER BLOWING 2.5 TIMES

1

4

4 4

3

2

SMART FAN DELIVERING THE REQUIRED AIRFLOW

ZONE 1

ZONE 3 ZONE 4

ZONE 2

250 L/s

STANDARD FAN L/s

ACTRON ECM SMART FAN L/s

THE REQUIRED AIRFLOW

Page 8: Digital Scroll Technology EC Fans - AIRAH · Inverter HSP LSP - SLIM Energy Efficiency (Digital) ESP ESP PLUS OPRT Standard Cycling Vertical Package ... FAN POWER CONSUMPTION STANDA

8

600

700

Airflow Requirement

200

300

400

500

Air Flow (Ls)

250% OVER BLOWING THE REQUIRED AIR FLOW

CONVENTIONAL SYSTEM

ACTRONAIR ESP PLUS

0

100

ONE ZONE

RD FAN

800

900

1000

1100FAN POWER CONSUMPTION

STANDAR

ACT

RON EC FAN

300

400

500

600

700

800

POW

ER (W

)

0

100

200

ALL ZONES ONE ZONE

Page 9: Digital Scroll Technology EC Fans - AIRAH · Inverter HSP LSP - SLIM Energy Efficiency (Digital) ESP ESP PLUS OPRT Standard Cycling Vertical Package ... FAN POWER CONSUMPTION STANDA

9

Questions??

An independent energy modeling analysis indicates that annual energy

Energy Saving Products

25

Calculated Annual Energy Consumption

gyconsumption for a 2 story, 4 bedroom brick veneer home in Sydney’s west is reduced by up to 60%when using ESP plus as opposed to a comparable conventional system

10

15

20

Pow

er (M

Wh)

60%0

5

CONVENTIONAL SYSTEM

ACTRONAIR ESP PLUS

The ESP Ultima Home

Page 10: Digital Scroll Technology EC Fans - AIRAH · Inverter HSP LSP - SLIM Energy Efficiency (Digital) ESP ESP PLUS OPRT Standard Cycling Vertical Package ... FAN POWER CONSUMPTION STANDA

10

OFFICE 1

STORE

Variable Air Volume (VAV) Technology for Light Commercial Applications

OFFICE 3

RECEPTION & SHOWROOM MEETING ROOM

WC

STOREROOM

OFFICE 2

Master Controller• Controls system operation, fan speeds and sets master temperature limits

Individual Zone Controller• Sets temperature for individual zone 

• On/Off temperature controls for the zone

Zone Sensor• Used in conjunction with master controller to improve temperature control

For maximum efficiency, the system has a default maximum temperature span of ±2°C between the master controller and individual zones.

OUTDOOR BOARD

DESIGN ANY COMBINATION

INDOOR BOARD

ULTIMAMODULE

AM7‐D8

Max Number of sensors is  = 16

Page 11: Digital Scroll Technology EC Fans - AIRAH · Inverter HSP LSP - SLIM Energy Efficiency (Digital) ESP ESP PLUS OPRT Standard Cycling Vertical Package ... FAN POWER CONSUMPTION STANDA

11

Net Cooling Capacity 12.5 14.5 16.6 18 19 23

Product Line-up

Outdoor 1PH

Outdoor 3PH

ESP

ESP Plus

ESP Ultima

Digital Vertical PackageDigital Vertical Package

Page 12: Digital Scroll Technology EC Fans - AIRAH · Inverter HSP LSP - SLIM Energy Efficiency (Digital) ESP ESP PLUS OPRT Standard Cycling Vertical Package ... FAN POWER CONSUMPTION STANDA

12

Digital Vertical Package (PMD)

Operating Range

Digital Scroll Compressor

EC Indoor Fan

Large Condenser Coil

High Ambient 3 speed condenser fan

Designed for Australian harsh environment in mind

Product Line-up

Total / Gross kW 11.5 16 19

Cooling Only – R Type • •Reverse Cycle – R Type • • •Cooling Only – X Type •Reverse Cycle – X Type • •

Page 13: Digital Scroll Technology EC Fans - AIRAH · Inverter HSP LSP - SLIM Energy Efficiency (Digital) ESP ESP PLUS OPRT Standard Cycling Vertical Package ... FAN POWER CONSUMPTION STANDA

13

Tri‐Capacity SeriesTri Capacity Series

Matching capacity to the load

6.2.2 Integrated Energy Efficiency Ratio (IEER). For equipment covered by this standard, the IEER shall be calculated using test derived data and the following formula.

IEER = (0.020 · A) + (0.617 · B) + (0.238 · C) + (0.125 · D)

Where:A = EER at 100% net capacity at AHRI standard rating conditionsB = EER at 75% net capacity and reduced ambientC = EER at 50% net capacity and reduced ambientD = EER at 25% net capacity and reduced ambient

• A ‘typical’ commercial building air conditioner operates between 60 to 75% capacity most of the time

• This observation is supported by the US calculation for IEER ratings (AHRI 340/360) for commercial ducted systems.

Page 14: Digital Scroll Technology EC Fans - AIRAH · Inverter HSP LSP - SLIM Energy Efficiency (Digital) ESP ESP PLUS OPRT Standard Cycling Vertical Package ... FAN POWER CONSUMPTION STANDA

14

Tri-capacity Compressor Operation

• Designed for improved seasonal efficiency• 2 compressors 470-700• 3 compressors for the 820 / 9603 compressors for the 820 / 960• 3 capacity steps of cooling/heating

~ 33%, ~67% and 100% capacity

PKY 820 / 960PKY 470 / 700

~67% ~33%~67% ~33%

100% Capacity

67%*Capacity67%

100%

Tri-capacity Operation 470 ~ 700

33%*Capacity33%

OnOffCompressor

2Compressor

1Compressor

1

OffCompressor

2

OnCompressor

1

OnCompressor

2

On

Page 15: Digital Scroll Technology EC Fans - AIRAH · Inverter HSP LSP - SLIM Energy Efficiency (Digital) ESP ESP PLUS OPRT Standard Cycling Vertical Package ... FAN POWER CONSUMPTION STANDA

15

100% Capacity

67%*C

100%

Tri-capacity Operation 820 / 960

33%*Capacity

Capacity

33%

67%

OnComp.

2

OnComp.

31

OnComp.

3Comp.

2

OffComp.

3

Off OffComp.

2

OnComp.

1

OnComp.

3

OnComp.

1

ebm-papst EC plug fans and EC HyBlade axial fans

Page 16: Digital Scroll Technology EC Fans - AIRAH · Inverter HSP LSP - SLIM Energy Efficiency (Digital) ESP ESP PLUS OPRT Standard Cycling Vertical Package ... FAN POWER CONSUMPTION STANDA

16

High Efficiency EC Plug Fan

• Delivers improved energy savings utilising:

– EC motor– Non overloading Backward Curved fan.

• Improved performance and efficiency vs. traditional forward curve belt and pulley systems

• Other advantages:– Greater flexibility of supply and return air configurations.y pp y g– High Static easily achieved. (Up to 500Pa)– Quick ‘dial-up’ air flow adjustment– Quiet start up, eliminates sudden start-up noises.

Product Line-up

Total / Gross kW 47.0 53.5 63.0 71.0 82.5 96.0

Packaged Unit (PKY) • • • • • •

Outdoor Unit (CAY) • • • •

Indoor Unit (EVY) • • • •Indoor Unit Low Profile(ELY) • • • •